1
|
Endo G, Ishigaki K, Hamada T, Nakai Y, Ishida K, Kurihara K, Tange S, Takaoka S, Tokito Y, Suzuki Y, Oyama H, Kanai S, Suzuki T, Sato T, Hakuta R, Saito T, Takahara N, Fujishiro M. The impact of biliary stents on the diagnostic yield of endoscopic ultrasound-guided fine needle aspiration for solid pancreatic lesions: A single-center retrospective study and meta-analysis. DEN OPEN 2024; 4:e250. [PMID: 37441156 PMCID: PMC10333724 DOI: 10.1002/deo2.250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/03/2023] [Accepted: 05/21/2023] [Indexed: 07/15/2023]
Abstract
Background Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is widely used for the pathological diagnosis of solid pancreatic lesions but in cases with obstructive jaundice, transpapillary sampling can be performed during endoscopic retrograde cholangiopancreatography with transpapillary biliary stent placement. Thus, it is still controversial whether EUS-FNA should be performed prior to endoscopic retrograde cholangiopancreatography with biliary stent placement or only after negative transpapillary sampling. Methods The accuracy, sensitivity, and specificity of EUS-FNA for solid pancreatic lesions with or without indwelling biliary stents were retrospectively studied in patients undergoing EUS-FNA between January 2017 and December 2021. We also conducted a meta-analysis including our data to compare the accuracy and sensitivity of EUS-FNA with or without biliary stents. Results A total of 509 patients (40 with biliary stents and 469 without biliary stents) were included. The accuracy (77.5% vs. 94.5%, p < 0.001) and sensitivity (71.0% vs. 91.7%, p < 0.001) were lower in EUS-FNA with biliary stents. A meta-analysis confirmed that accuracy (odds ratio [OR] of 0.43, 95% confidence interval [CI] 0.29-0.62, p < 0.001) and sensitivity (OR of 0.46, 95% CI 0.33-0.64, p < 0.001) were lower in EUS-FNA with biliary stents. There were no statistically significant differences between plastic stents and self-expandable metallic stents for accuracy or sensitivity. Conclusions The presence of biliary stents had a negative impact on the diagnostic performance of EUS-FNA, and EUS-FNA prior to endoscopic retrograde cholangiopancreatography with biliary stent placement should be considered in cases with obstructive jaundice.
Collapse
Affiliation(s)
- Go Endo
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Kazunaga Ishigaki
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
- Department of Chemotherapythe University of Tokyo HospitalTokyoJapan
| | - Tsuyoshi Hamada
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Yousuke Nakai
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
- Department of Endoscopy and Endoscopic Surgerythe University of Tokyo HospitalTokyoJapan
| | - Kota Ishida
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Kohei Kurihara
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Shuichi Tange
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Shinya Takaoka
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Yurie Tokito
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Yukari Suzuki
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Hiroki Oyama
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Sachiko Kanai
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
- Department of Endoscopy and Endoscopic Surgerythe University of Tokyo HospitalTokyoJapan
| | - Tatsunori Suzuki
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Tatsuya Sato
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Ryunosuke Hakuta
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Tomotaka Saito
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Naminatsu Takahara
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| | - Mitsuhiro Fujishiro
- Department of GastroenterologyGraduate School of Medicinethe University of TokyoTokyoJapan
| |
Collapse
|
2
|
Guzmán-Calderón E, Chacaltana A, Díaz-Arocutipa C, Díaz R, Arcana R, Aparicio JR. Impact of biliary stents in the performance of the EUS-guided tissue acquisition: A systematic review and meta-analysis. GASTROENTEROLOGIA Y HEPATOLOGIA 2024; 47:327-336. [PMID: 37285933 DOI: 10.1016/j.gastrohep.2023.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 05/24/2023] [Accepted: 05/29/2023] [Indexed: 06/09/2023]
Abstract
INTRODUCTION AND AIM Pancreatobiliary tumours are challenging to diagnose exclusively by imaging methods. Although the optimum moment for carrying out the EUS is not well defined, it has been suggested that the presence of biliary stents may interfere with the proper staging of tumours and the acquisition of samples. We performed a meta-analysis to evaluate the impact of biliary stents on EUS-guided tissue acquisition yield. MATERIAL AND METHODS We conducted a systematic review in different databases, such as PubMed, Cochrane, Medline, and OVID Database. A search was made of all studies published up to February 2022. RESULTS Eight studies were analyzed. A total of 3185 patients were included. The mean age was 66.9±2.7 years; 55.4% were male gender. Overall, 1761 patients (55.3%) underwent EUS guided tissue acquisition (EUS-TA) with stents in situ, whereas 1424 patients (44.7%) underwent EUS-TA without stents. The technical success was similar in both groups (EUS-TA with stents: 88% vs EUS-TA without stents: 88%, OR=0.92 [95% CI 0.55-1.56]). The type of stent, the needle size and the number of the passes were similar in both groups. CONCLUSIONS EUS-TA has similar diagnostic performance and technical success in patients with or without stents. The type of stent (SEMS or plastic) does not seem to influence the diagnostic performance of EUS-TA. Future prospectives and RCT studies are needed to strengthen these conclusions.
Collapse
Affiliation(s)
- Edson Guzmán-Calderón
- Gastroenterology Unit of Hospital Nacional Edgardo Rebagliati Martins, Lima, Peru; Universidad Peruana de Ciencias Aplicadas (UPC), Peru; Gastroenterology Unit of Angloamericana Clinic, Lima, Peru.
| | - Alfonso Chacaltana
- Gastroenterology Unit of Hospital Nacional Edgardo Rebagliati Martins, Lima, Peru
| | | | - Ramiro Díaz
- Gastroenterology Unit of Hospital Nacional Edgardo Rebagliati Martins, Lima, Peru
| | - Ronald Arcana
- Gastroenterology Unit of Hospital Nacional Edgardo Rebagliati Martins, Lima, Peru
| | - José Ramón Aparicio
- Gastroenterology Unit of Hospital General Universitario de Alicante, Alicante, Spain
| |
Collapse
|
3
|
Facciorusso A, Chandan S, Gkolfakis P, Ramai D, Mohan BP, Lisotti A, Conti Bellocchi MC, Papanikolaou IS, Mangiavillano B, Triantafyllou K, Manthopoulou E, Mare R, Fusaroli P, Crinò SF. Do Biliary Stents Affect EUS-Guided Tissue Acquisition (EUS-TA) in Solid Pancreatic Lesions Determining Biliary Obstruction? A Literature Review with Meta-Analysis. Cancers (Basel) 2023; 15:1789. [PMID: 36980675 PMCID: PMC10046620 DOI: 10.3390/cancers15061789] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 03/06/2023] [Accepted: 03/14/2023] [Indexed: 03/18/2023] Open
Abstract
There is a paucity of evidence regarding whether biliary stents influence endoscopic ultrasound-guided tissue acquisition using either fine-needle biopsy (EUS-FNB) or fine-needle aspiration (EUS-FNA), among patients with head of pancreas (HOP) lesions. We aimed at assessing the diagnostic accuracy of endoscopic ultrasound-guided tissue sampling in patients with or without bile duct stents. A total of seven studies with 2458 patients were included. The main aim was to assess overall pooled diagnostic accuracy. A pairwise meta-analysis was performed using a random effects model. Outcomes were expressed as odds ratios (ORs) with 95% confidence intervals (CIs). We found that pooled accuracy was 85.4% (CI 78.8-91.9) and 88.1% (CI 83.3-92.9) in patients with and without stents, respectively. There was no statistically significant difference between the two (OR 0.74; p = 0.07). Furthermore, patients with metal stents demonstrated a significant difference (OR 0.54, 0.17-0.97; p = 0.05), which was not seen with plastic stents. EUS-FNB showed poorer diagnostic accuracy with concurrent biliary stenting (OR 0.64, 0.43-0.95; p = 0.03); however, the same was not observed with EUS-FNA. Compared to plastic stents, metal biliary stenting further impacted the diagnostic accuracy of EUS-guided tissue acquisition for pancreatic head lesions. There was no difference in the rate of procedure-related adverse events between the stent and no-stent groups.
Collapse
Affiliation(s)
- Antonio Facciorusso
- Gastroenterology Unit, Department of Surgical and Medical Sciences, University of Foggia, 71122 Foggia, Italy
| | - Saurabh Chandan
- Gastroenterology Unit, CHI Health Creighton University Medical Center, Omaha, NE 68007, USA
| | - Paraskevas Gkolfakis
- Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, CUB Erasme Hospital, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium
| | - Daryl Ramai
- Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, UT 801385, USA
| | - Babu P. Mohan
- Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, UT 801385, USA
| | - Andrea Lisotti
- Gastroenterology Unit, Hospital of Imola, 40026 Imola, Italy
| | - Maria Cristina Conti Bellocchi
- Gastroenterology and Digestive Endoscopy Unit, Department of Medicine, The Pancreas Institute, University Hospital of Verona, 37100 Verona, Italy
| | - Ioannis S. Papanikolaou
- Hepatogastroenterology Unit, Second Department of Internal Medicine-Propaedeutic, Medical School, “Attikon” University General Hospital, National and Kapodistrian University of Athens, 10431 Athens, Greece
| | - Benedetto Mangiavillano
- Gastrointestinal Endoscopy Unit, Humanitas Mater Domini, Via Gerenzano 2, 21053 Castellanza, Italy
| | - Konstantinos Triantafyllou
- Hepatogastroenterology Unit, Second Department of Internal Medicine-Propaedeutic, Medical School, “Attikon” University General Hospital, National and Kapodistrian University of Athens, 10431 Athens, Greece
| | - Eleni Manthopoulou
- Department of Gastroenterology, St. Savvas Oncology Hospital of Athens, 10431 Athens, Greece
| | - Ruxandra Mare
- Gastroenterology Unit, Department of Internal Medicine II, “Victor Babes” University of Medicine and Pharmacy, 300226 Timisoara, Romania
| | - Pietro Fusaroli
- Gastroenterology Unit, Hospital of Imola, 40026 Imola, Italy
| | - Stefano Francesco Crinò
- Gastroenterology and Digestive Endoscopy Unit, Department of Medicine, The Pancreas Institute, University Hospital of Verona, 37100 Verona, Italy
| |
Collapse
|
4
|
Giri S, Afzalpurkar S, Angadi S, Varghese J, Sundaram S. Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis. Clin Endosc 2023; 56:169-179. [PMID: 37013391 PMCID: PMC10073854 DOI: 10.5946/ce.2022.282] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 12/16/2022] [Indexed: 04/05/2023] Open
Abstract
BACKGROUND/AIMS This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. METHODS A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-TA in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. RESULTS Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. CONCLUSION The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.
Collapse
Affiliation(s)
- Suprabhat Giri
- Department of Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Shivaraj Afzalpurkar
- Institute of Gastrosciences and Liver, Apollo Multispecialty Hospital, Kolkata, India
| | - Sumaswi Angadi
- Department of Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Jijo Varghese
- Department of Gastroenterology, KM Cherian Institute of Medical Sciences, Kallissery, India
| | - Sridhar Sundaram
- Department of Digestive Disease and Clinical Nutrition, Tata Memorial Hospital, Mumbai, India
| |
Collapse
|
5
|
Matsubayashi H, Sasaki K, Ono S, Ishiwatari H, Ishikawa K, Satoh T, Kimura H, Kakushima N, Yoshida M, Yabuuchi Y, Kishida Y, Imai K, Sugiura T, Ono H. Efficacy of endoscopic samplings during initial biliary drainage for cases of pancreatic head cancer: United diagnostic yields of multiple pathological samplings. Pancreatology 2021; 21:1548-1554. [PMID: 34607772 DOI: 10.1016/j.pan.2021.09.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 08/21/2021] [Accepted: 09/25/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND/OBJECTIVES The diagnostic ability of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has been fully studied; however, the efficacy of other endoscopic samplings (OESs) is less clear. The aim of this study was to examine the diagnostic efficacies of OESs for pancreatic head cancer (PHC). METHODS The diagnostic efficacies of endoscopic samplings were retrospectively analyzed in 448 PHC cases and 63 cases of mass-forming pancreatitis (MFP) during initial transpapillary biliary drainage. The OESs included duodenal biopsy (118 PHCs and 50 MFPs), biliary biopsy (218 and 51) with cytology (368 and 53), and pancreatic duct biopsy (23 and 13) with cytology (56 and 43). EUS-FNA was conducted in a different session (149 and 62). Factors associated with OES sensitivity were analyzed. The sensitivity of biliary biopsy was compared between 1.95 mm and 1.8 mm forceps. RESULTS Cancer cells were confirmed in 87.9% of the EUS-FNA samplings and in 64.1% (268/418) obtained by combined OESs (average 1.7 OES types per case): 68.6% by duodenal biopsy, 59.6% by biliary biopsy, 32.6% by biliary cytology, 73.9% by pancreatic duct biopsy, and 33.9% by pancreatic duct cytology. No MFP cases revealed cancer by any sampling. OESs did not increase adverse events. Duodenal stenosis, serum bilirubin, tumor size, and pancreatic juice amounts were associated with OES sensitivity. Biliary biopsy had the same sensitivity with different forceps. CONCLUSION EUS-FNA was the most diagnostic protocol; however, OESs can be safely applied during the initial biliary drainage to reduce the demand for EUS-FNA while providing good diagnostic yields.
Collapse
Affiliation(s)
- Hiroyuki Matsubayashi
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan; Division of Genetic Medicine Promotion, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan.
| | - Keiko Sasaki
- Division of Pathology, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Sachiyo Ono
- Division of Pathology, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Hirotoshi Ishiwatari
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Kazuma Ishikawa
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Tatsunori Satoh
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Hidenori Kimura
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Naomi Kakushima
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Masao Yoshida
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Yohei Yabuuchi
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Yoshihiro Kishida
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Kenichiro Imai
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Teichi Sugiura
- Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| | - Hiroyuki Ono
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Suntogun, Shizuoka, 411-8777, Japan
| |
Collapse
|
6
|
Crinò SF, Conti Bellocchi MC, Antonini F, Macarri G, Carrara S, Lamonaca L, Di Mitri R, Conte E, Fabbri C, Binda C, Ofosu A, Gasparini E, Turri C, Stornello C, Celsa C, Larghi A, Manfrin E, Gabbrielli A, Facciorusso A, Tacelli M. Impact of biliary stents on the diagnostic accuracy of EUS-guided fine-needle biopsy of solid pancreatic head lesions: A multicenter study. Endosc Ultrasound 2021; 10:440-447. [PMID: 34975042 PMCID: PMC8785671 DOI: 10.4103/eus-d-21-00118] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Background and Objectives There is no clear evidence of a negative impact of biliary stents on the diagnostic yield of EUS-guided fine-needle biopsy (EUS-FNB) for diagnosing pancreatic head lesions. We aimed to evaluate the association between the presence of biliary stents and the diagnostic accuracy of EUS-FNB. Materials and Methods A multicenter retrospective study including all jaundiced patients secondary to pancreatic head masses was performed. Patients were divided into two groups according to the presence of a biliary stent placed before EUS-FNB. Pathological results were classified according to the Papanicolaou classification and compared against the final diagnosis. Diagnostic measures in the two groups were compared. Multivariate logistic regression analyses including potential factors affecting EUS-FNB accuracy were performed. Results Overall, 842 patients were included, 495 (58.8%) without and 347 (41.2%) with biliary stent. A plastic or a metal stent was placed in 217 (62.5%) and 130 (37.5%) cases, respectively. Diagnostic sensitivity and accuracy were significantly higher in patients without biliary stent than in those with stent (91.9% and 92.1% vs. 85.9% and 86.4%, P = 0.010 At multivariate analyses, lesion size (odds ratio [OR]: 1.05, 95% confidence interval [CI]: 1.02-1.09, P = 0.01) and presence of biliary stent (OR: 0.51, 95% CI: 0.32-0.89, P = 0.01) were independently associated with diagnostic accuracy. In the subgroup of patients with biliary stent, the type of stent (plastic vs. metal) did not impact EUS-FNB yield, whereas the use of larger bore needles enhanced diagnostic accuracy (OR: 2.29, 95% CI: 1.28-4.12, P = 0.005). Conclusions In this large retrospective study, an indwelling biliary stent negatively impacted the diagnostic accuracy of EUS-FNB. Preferably, EUS-FNB should precede endoscopic retrograde cholangiopancreatography, especially in the case of small tumors.
Collapse
Affiliation(s)
- Stefano Francesco Crinò
- Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, G.B. Rossi University Hospital, Verona, Italy
| | | | - Filippo Antonini
- Gastroenterology and Digestive Endoscopy Unit, Augusto Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Giampiero Macarri
- Gastroenterology and Digestive Endoscopy Unit, Augusto Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Silvia Carrara
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Milan, Italy
| | - Laura Lamonaca
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Milan, Italy
| | - Roberto Di Mitri
- Gastroenterology and Endoscopy Unit, Arnas Civico Di Cristina Benfratelli Hospital, Palermo, Italy
| | - Elisabetta Conte
- Gastroenterology and Endoscopy Unit, Arnas Civico Di Cristina Benfratelli Hospital, Palermo, Italy
| | - Carlo Fabbri
- Gastroenterology and Digestive Endoscopy Unit, Forli-Cesena Hospitals, AUSL Romagna, Italy
| | - Cecilia Binda
- Gastroenterology and Digestive Endoscopy Unit, Forli-Cesena Hospitals, AUSL Romagna, Italy
| | - Andrew Ofosu
- Division of Gastroenterology and Hepatology, Stanford University School of Medicine, Stanford, California, USA
| | - Enrico Gasparini
- Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, G.B. Rossi University Hospital, Verona, Italy
| | - Chiara Turri
- Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, G.B. Rossi University Hospital, Verona, Italy
| | - Caterina Stornello
- Section of Gastroenterology and Hepatology, Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, University of Palermo, Italy
| | - Ciro Celsa
- Section of Gastroenterology and Hepatology, Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties; Department of Surgical, Oncological and Oral Sciences (Di.Chir.On.S.), University of Palermo, Italy
| | - Alberto Larghi
- Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli, Roma, Italy
| | - Erminia Manfrin
- Department of Diagnostics and Public Health, G.B. Rossi University Hospital, Verona, Italy
| | - Armando Gabbrielli
- Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, G.B. Rossi University Hospital, Verona, Italy
| | - Antonio Facciorusso
- Digestive Endoscopy Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy
| | - Matteo Tacelli
- Pancreato-biliary Endoscopy and EUS Division, San Raffaele Scientific Institute IRCCS, Milan, Italy
| |
Collapse
|
7
|
Dietrich CF, Bekkali NL, Burmeister S, Dong Y, Everett SM, Hocke M, Ignee A, On W, Hebbar S, Oppong K, Sun S, Jenssen C, Braden B. Controversies in ERCP: Indications and preparation. Endosc Ultrasound 2021; 11:186-200. [PMID: 34677145 PMCID: PMC9258020 DOI: 10.4103/eus-d-21-00106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The aim of the series of papers on controversies of biliopancreatic drainage procedures is to discuss the pros and cons of the varying clinical practices and techniques in ERCP and EUS for drainage of biliary and pancreatic ducts. The first part focuses on indications, clinical and imaging prerequisites before ERCP, sedation options, post-ERCP pancreatitis (PEP) prophylaxis, and other related technical topics. In the second part, specific procedural ERCP-techniques including precut techniques and its timing as well as management algorithms are discussed. In addition, controversies in EUS-guided bile duct and pancreatic drainage procedures are under preparation.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Department of Ultrasound, The First Affiliated Hospital of Zhengzhou University, China; Johann Wolfgang Goethe University, Frankfurt/Main, Germany; Department of Allgemeine Innere Medizin, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| | - Noor L Bekkali
- Translational Gastroenterology Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Sean Burmeister
- Surgical Gastroenterology Unit, Groote Schuur Hospital, Cape Town, South Africa
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | | | - Michael Hocke
- Medical Department, Helios Klinikum Meiningen, Meiningen, Germany
| | - Andre Ignee
- Medical Department 2, Caritas-Krankenhaus, Uhlandstr 7, D-97980 Bad Mergentheim, Germany
| | - Wei On
- Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Srisha Hebbar
- University Hospitals of North Midlands, North Midlands, United Kingdom
| | - Kofi Oppong
- HPB Unit, Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - Siyu Sun
- Endoscopy Center, Sheng Jing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Markisch-Oderland, Strausberg; Brandenburg Institute for Clinical Ultrasound at Medical University Brandenburg, Neuruppin, Germany
| | - Barbara Braden
- Translational Gastroenterology Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Johann Wolfgang Goethe University, Frankfurt/Main, Germany
| |
Collapse
|
8
|
Fabbri C, Fornelli A, Fuccio L, Giovanelli S, Tarantino I, Antonini F, Liotta R, Frazzoni L, Gusella P, La Marca M, Barresi L, Macarri G, Traina M, De Biase D, Fiorino S, Jovine E, Larghi A, Cennamo V. High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study. Endosc Ultrasound 2019; 8:261-268. [PMID: 31115386 PMCID: PMC6714486 DOI: 10.4103/eus.eus_14_19] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 02/05/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND AND OBJECTIVE EUS-guided fine-needle biopsy has become the standard for tissue sampling. A new 20G ProCore™ (PC) needle has been developed to overcome the limitations of tissue acquisition of the smaller needles (22G, 25G) and the rigidity of the larger one (19G). The aim of this study is to assess the performance of the 20G PC needle. MATERIALS AND METHODS Patients who underwent EUS-guided tissue acquisition with the 20G PC needle of pancreatic and extra-pancreatic mass lesions were retrospectively identified at three Italian centers (Bologna, Fermo, and Palermo). Diagnostic adequacy, accuracy, and tissue core acquisition were the outcome measures. All the cases were performed without rapid on-site evaluation. RESULTS A total of 384 patients with pancreatic (62.2%) and extra-pancreatic lesions were included in the study. For pancreatic lesions, adequacy, accuracy, sensitivity, and specificity were 92.4%, 91.5%, 90.8%, and 100%, respectively, with a number needed to misdiagnose (NNM) of 11.8. The tissue core was obtained in 72% of cases. Transduodenal approach was performed in 150 pancreatic lesions; adequacy, accuracy, and tissue core acquisition were 88.7%, 90%, and 66%, respectively (NNM 10). For extrapancreatic lesions, adequacy, accuracy, sensitivity, specificity, and tissue core sampling were 95.3%, 95.3%, 92.6%, 100%, and 84.5% (NNM 21.3). CONCLUSIONS The 20G PC needle showed high diagnostic adequacy and accuracy, regardless the access route.
Collapse
Affiliation(s)
- Carlo Fabbri
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Adele Fornelli
- Pathology Service, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Lorenzo Fuccio
- Department of Medical and Surgical Sciences, Divison of Gastroenterology, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Silvia Giovanelli
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Ilaria Tarantino
- Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies, Palermo, Italy
| | - Filippo Antonini
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Rosa Liotta
- Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies, Palermo, Italy
| | - Leonardo Frazzoni
- Department of Medical and Surgical Sciences, Divison of Gastroenterology, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Paolo Gusella
- Pathology Service, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Marina La Marca
- Department of Medical and Surgical Sciences, Divison of Gastroenterology, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Luca Barresi
- Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies, Palermo, Italy
| | - Giampiero Macarri
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Mario Traina
- Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies, Palermo, Italy
| | - Dario De Biase
- Pathology Service, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Siro Fiorino
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Elio Jovine
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Alberto Larghi
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Vincenzo Cennamo
- Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| |
Collapse
|
9
|
Sun B, Moon JH, Cai Q, Rerknimitr R, Ma S, Lakhtakia S, Ryozawa S, Kutsumi H, Yasuda I, Shiomi H, Li X, Li W, Zhang X, Itoi T, Wang HP, Qian D, Wong Lau JY, Yang Z, Ji M, Hu B. Review article: Asia-Pacific consensus recommendations on endoscopic tissue acquisition for biliary strictures. Aliment Pharmacol Ther 2018; 48:138-151. [PMID: 29876948 DOI: 10.1111/apt.14811] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2018] [Revised: 03/23/2018] [Accepted: 04/26/2018] [Indexed: 12/12/2022]
Abstract
BACKGROUND Pre-operative tissue diagnosis for suspected malignant biliary strictures remains challenging. AIM To develop evidence-based consensus statements on endoscopic tissue acquisition for biliary strictures. METHODS The initial draft of statements was prepared following a systematic literature review. A committee of 20 experts from Asia-Pacific region then reviewed, discussed, and modified the statements. Two rounds of independent voting were conducted to reach a final version. Consensus was considered to be achieved when 80% or more of voting members voted "agree completely" or "agree with some reservation." RESULTS Eleven statements achieved consensus. The choice of tissue sampling modalities for biliary strictures depends on the clinical setting, the location of lesion, and availability of expertise. Detailed radiological and endoscopic evaluation is useful to guide the selection of appropriate tissue acquisition technique. Standard intraductal biliary brushing and/or forceps biopsy is the first option when endoscopic biliary drainage is required with an overall (range) sensitivity and specificity of 45% (26%-72%) and 99% (98%-100%), and 48% (15%-100%) and 99% (97%-100%), respectively, in diagnosing malignant biliary strictures. Probe-based confocal laser endomicroscopy and fluorescence in situ hybridisation using 4 fluorescent-labelled probes targeting chromosomes 3, 7, 17 and 9p21 locus may be added to improve the diagnostic yield. Cholangioscopy-guided biopsy and EUS-guided tissue acquisition can be considered after prior negative conventional tissue sampling with an overall (range) sensitivity and specificity of 60% (38%-88%) and 98% (83%-100%), and 80% (46%-100%) and 97% (92%-100%), respectively, in diagnosing malignant biliary strictures. CONCLUSION These consensus statements provide evidence-based recommendations for endoscopic tissue acquisition of biliary strictures.
Collapse
|
10
|
Antonini F, Giorgini S, Fuccio L, Angelelli L, Macarri G. EUS-guided sampling with 25G biopsy needle as a rescue strategy for diagnosis of small subepithelial lesions of the upper gastrointestinal tract. Endosc Int Open 2018; 6:E892-E897. [PMID: 29978011 PMCID: PMC6032639 DOI: 10.1055/a-0603-3578] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Accepted: 03/13/2018] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND AND STUDY AIMS This study was designed to evaluate the impact of additional tissue obtained with endoscopic ultrasound (EUS)-guided 25-gauge core biopsy needle (25G-PC) following an unsuccessful fine-needle biopsy (FNB) performed with larger-bore needles for the characterization of gastrointestinal subepithelial lesions (GI-SELs). PATIENTS AND METHODS We prospectively collected and retrospectively analyzed information in our database from January 2013 to June 2017 for all patients with GI-SELs who received a EUS-guided FNB (EUS-FNB) with 25G-PC during the same procedure after failure of biopsy performed with larger-bore needle. Diagnostic yield, diagnostic accuracy and procedural complications were evaluated. RESULTS Sixteen patients were included in this study, 10 men and 6 women, median age 67.8 (range 43 to 76 years). Five patients were found to have a SEL localized in the distal duodenum, five in the gastric antrum, two in the gastric fundus and four in the gastric body. The mean size of the lesions was 20.5 mm (range 18 - 24 mm). EUS-FNB with 25G-PC enabled final diagnosis in nine patients (56.2 %). Regarding the subgroup of duodenal lesions, the procedure was successful in four of five (80 %). Final diagnoses with EUS-guided sampling were GIST (n = 6), leiomyoma (n = 2) and metastatic ovarian carcinoma (n = 1). No procedure-related complications were recorded. CONCLUSION In patients with small GI-SELs, additional tissue obtained with 25G-PC could represents a "rescue" strategy after an unsuccessful procedure with larger-bore needles, especially when lesions are localized in the distal duodenum.
Collapse
Affiliation(s)
- Filippo Antonini
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy,Corresponding author Filippo Antonini, MD UOC Gastroenterologia ed Endoscopia DigestivaUniversità Politecnica delle MarcheOspedale “A.Murri”63900 – FermoItaly+39.0734.6252252
| | - Sara Giorgini
- Pathological Anatomy and Histopathology, Department of Biomedical Sciences and Public Health, Polytechnic University of Marche, Ancona, Italy
| | - Lorenzo Fuccio
- Department of Medical and Surgical Sciences, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | | | - Giampiero Macarri
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| |
Collapse
|