1
|
Burkule N, Bansal M, Govind S, Alagesan R, Ponde C, Parashar S. Corrected and Republished: Indian Academy of Echocardiography Guidelines for Performance of Transesophageal Echocardiography in Adults. JOURNAL OF THE INDIAN ACADEMY OF ECHOCARDIOGRAPHY & CARDIOVASCULAR IMAGING 2022. [DOI: 10.4103/jiae.jiae_54_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
2
|
Burkule N, Bansal M, Govind S, Alagesan R, Ponde C, Parashar S. Indian Academy of Echocardiography Guidelines for Performance of Transesophageal Echocardiography in Adults. JOURNAL OF THE INDIAN ACADEMY OF ECHOCARDIOGRAPHY & CARDIOVASCULAR IMAGING 2021. [DOI: 10.4103/jiae.jiae_39_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
3
|
Tufaro V, Butera G. Fenestrated ASD device "angioplasty": How to adjust a "pop-off" mechanism when needed. Catheter Cardiovasc Interv 2018; 92:1329-1333. [PMID: 30196540 DOI: 10.1002/ccd.27788] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 05/29/2018] [Accepted: 06/20/2018] [Indexed: 11/07/2022]
Abstract
We report on three cases of atrial septal defect (ASD) closure where a handmade fenestration had to be modified after device implantation. Two patients suffered from left ventricular diastolic dysfunction and one had severe pulmonary arterial hypertension. Amplatzer ASD occluder fenestration was created in all patients. Devices were implanted using an "over-the-wire" implantation technique. Due to a sub-optimal hemodynamic result, fenestration was upsized by using a new technique.
Collapse
Affiliation(s)
- Vincenzo Tufaro
- Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Gianfranco Butera
- Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| |
Collapse
|
4
|
Raut MS, Maheshwari A, Dubey S, Shivnani G, Makhija A, Mohanty A. Eustachian valve - Masquerading ASD rim. Indian Heart J 2016; 68:368-9. [PMID: 27316494 PMCID: PMC4911437 DOI: 10.1016/j.ihj.2016.03.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 03/22/2016] [Indexed: 12/12/2022] Open
Affiliation(s)
- Monish S Raut
- Department of Cardiac Anesthesiology, Sir Ganga Ram Hospital, New Delhi, India.
| | - Arun Maheshwari
- Department of Cardiac Anesthesiology, Sir Ganga Ram Hospital, New Delhi, India
| | - Sumir Dubey
- Department of Cardiac Surgery, Sir Ganga Ram Hospital, New Delhi, India
| | - Ganesh Shivnani
- Department of Cardiac Surgery, Sir Ganga Ram Hospital, New Delhi, India
| | - Aman Makhija
- Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
| | - Arun Mohanty
- Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
| |
Collapse
|
5
|
Leissner KB, Porhomayon J, Nader ND. Persistent Atrial Septum Defect Despite Placement of Two Amplatzer Septal Occluders. J Cardiovasc Thorac Res 2015; 7:172-4. [PMID: 26702348 PMCID: PMC4685285 DOI: 10.15171/jcvtr.2015.37] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Accepted: 08/01/2015] [Indexed: 11/21/2022] Open
Abstract
Herein, we are presenting a case of persistent interatrial septal defect diagnosed during coronary artery bypass grafting (CABG). Twice, attempts had been made to close this shunt using amplatzer septal occlude. However, percutaneous technique had failed in both occasions. The patient presented with chest pain 4 years after the second attempt and required urgent CABG. Persistent shunt was repaired during surgery.
Collapse
Affiliation(s)
- Kay B Leissner
- Department of Anesthesiology, Harvard Medical School, Boston, MA, USA ; Department of Anesthesiology, Boston University School of Medicine, Boston, MA, USA
| | - Jahan Porhomayon
- Department of Anesthesiology and Critical Care Medicine, University at Buffalo, Buffalo, NY, USA
| | - Nader D Nader
- Department of Anesthesiology and Critical Care Medicine, University at Buffalo, Buffalo, NY, USA
| |
Collapse
|
6
|
Bissessor N. Current perspectives in percutaneous atrial septal defect closure devices. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2015; 8:297-303. [PMID: 26203289 PMCID: PMC4508077 DOI: 10.2147/mder.s49368] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
In the last decade, percutaneous atrial septal defect (ASD) closure has become the treatment of choice in most clinical presentations of ASD. Percutaneous ASD closure has established procedural safety through operator experience and improved device structure and deliverability. There have also been advances in diagnostic capabilities. Devices have evolved from large bulky meshes to repositionable, minimal residual mesh content that easily endothelializes and conforms well to surrounding structures. Biodegradable technology has been introduced and will be closely watched as a future option. The evolution of ASD closure device usage in the last four decades incorporates development that minimizes a wide range of serious side effects that have been reported over the years. Complications reported in the literature include thrombus formation, air embolization, device embolization, erosions, residual shunts, and nickel hypersensitivity. Modern devices have intermediate to long term data with outcomes that have been favorable. Devices are available in multiple sizes with improved delivery mechanisms to recapture, reposition, and safely close simple and complex ASDs amenable to percutaneous closure. In this review, commonly used devices and deployment procedures are discussed together with a look at devices that show promise for the future.
Collapse
Affiliation(s)
- N Bissessor
- Department of Cardiology, The Epworth Hospital, Melbourne, VIC, Australia
- Division of Interventional Cardiology, The Alfred Hospital, Melbourne, VIC, Australia
- Department of Clinical Science, Charles Sturt University Albury Campus, NSW, Australia
- Heart Foundation, Griffith University, QLD, Australia
| |
Collapse
|
7
|
McGhie JS, van den Bosch AE, Haarman MG, Ren B, Roos-Hesselink JW, Witsenburg M, Geleijnse ML. Characterization of atrial septal defect by simultaneous multiplane two-dimensional echocardiography. Eur Heart J Cardiovasc Imaging 2014; 15:1145-51. [PMID: 24864120 DOI: 10.1093/ehjci/jeu098] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS The aim of this study was to assess the value of two-dimensional (2D) transthoracic simultaneous multiplane imaging (SMPI) in the evaluation of suitability for percutaneous atrial septal secundum defect (ASD) closure compared with the golden standard 2D transoesophageal echocardiography (TEE). METHODS AND RESULTS Twenty-nine patients with an ASD underwent both SMPI and TEE. Ten patients (34%) were male (age 41 ± 18 years, range 20-74). SMPI assessment of ASD size and rims included xPlane and I-rotate modes. Rims were defined as suitable for ASD percutaneous closure using a cut-off value of 5 mm. There were no significant differences between SMPI in xPlane mode and TEE regarding the sizes of the anterior-posterior dimension (13.7 ± 4.5 vs. 14.5 ± 5.2 mm) and superior-inferior dimension (13.5 ± 3.9 vs. 14.1 ± 5.0 mm, respectively). Agreement for the aortic, atrioventricular, inferior, right upper pulmonary vein, and superior rims was 100, 100, 100, 96, and 96%, respectively. CONCLUSION The SMPI technique can reliably assess the dimensions and rim size of a secundum ASD for pre-interventional selection when compared with TEE and has thus the potential to replace TEE.
Collapse
Affiliation(s)
- Jackie S McGhie
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Annemien E van den Bosch
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Meindina G Haarman
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Ben Ren
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Jolien W Roos-Hesselink
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Maarten Witsenburg
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| | - Marcel L Geleijnse
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Room BA 302, 's-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands
| |
Collapse
|
8
|
McGhie JS, Vletter WB, de Groot-de Laat LE, Ren B, Frowijn R, van den Bosch AE, Soliman OII, Geleijnse ML. Contributions of simultaneous multiplane echocardiographic imaging in daily clinical practice. Echocardiography 2013; 31:245-54. [PMID: 24138028 DOI: 10.1111/echo.12407] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Affiliation(s)
- Jackie S McGhie
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Evaluation of morphological characteristics of septal rims affecting successful transcatheter atrial septal defect closure in children and adults. ADVANCES IN INTERVENTIONAL CARDIOLOGY 2013; 9:205-11. [PMID: 24570720 PMCID: PMC3915979 DOI: 10.5114/pwki.2013.37497] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 04/26/2013] [Accepted: 05/09/2013] [Indexed: 11/17/2022] Open
Abstract
Introduction Determining other echocardiographic predictors along with the measured atrial septal defect (ASD) size and evaluating the closure together with these predictors would increase the chance of success for transcatheter closure of ASD. Aim To evaluate echocardiographic parameters affecting defect closure in children and adult patients with secundum ASD. Material and methods In all patients, size of ASD, total length of atrial septum (TS), superior-posterior, inferior-posterior, superior-anterior and inferior-anterior rims surrounding the defect were measured by transesophageal echocardiography (TEE), and several measurement ratios were derived on the basis of TEE parameters. Results A total 216 patients with secundum ASD were included in this study. The device was successfully implanted in 65 children and 65 adults. Both in pediatric and adult cases, the ratio of successful closure was found to be significantly higher when the ratio of defect size to TS was ≤ 0.35, the ratio of superior-anterior (SA) rim to the defect size was > 0.75 and the ratio of inferior-posterior (IP) rim to the defect size was > 1.0. It was found that having more than one of these predictors in a single case increased the chance of closure success significantly (p < 0.001). Conclusions We concluded that a ratio of the defect size to TS ≤ 0.35, a ratio of SA rim to defect size > 0.75 and a ratio of IP rim to defect size > 1.0 were found to be echocardiographic predictors that could be used in successful transcatheter ASD closure both in children and adults.
Collapse
|
10
|
Freixa X, Ibrahim R, Chan J, Garceau P, Dore A, Marcotte F, Mercier LA, Mongeon FP, Basmadjian A, Khairy P, Asgar AW. Initial clinical experience with the GORE septal occluder for the treatment of atrial septal defects and patent foramen ovale. EUROINTERVENTION 2013; 9:629-35. [DOI: 10.4244/eijv9i5a100] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
Clinical advantage of real-time three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects. Int J Cardiovasc Imaging 2013; 29:1273-80. [PMID: 23609549 DOI: 10.1007/s10554-013-0212-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Accepted: 03/26/2013] [Indexed: 10/26/2022]
Abstract
This study sought to evaluate the usefulness of real-time three-dimensional (3D) transesophageal echocardiography (TEE) to guide the repair of multiple atrial septal defects (ASDs). Of 212 consecutive patients with secundum ASD who were scheduled for transcatheter closure of their ASDs, 27 had multiple ASDs. These patients underwent two-dimensional (2D) transthoracic echocardiography, 2D TEE, and 3D TEE. Overall, 18 patients had two defects, and 9 patients had three or more defects. The latter group included three patients with multi-fenestrated defects. Optimal 3D images were obtained in 93 % of the patients. In patients with two defects, information on the positional relation of the defects was obtained using 2D TEE and 3D TEE in 71 and 94 % of patients, respectively (P = 0.22). The positional relations of the defects could not be evaluated with 2D TEE in patients with three or more defects, whereas it could be evaluated with 3D TEE in all of these patients (0 vs. 100 %, P = 0.008). In all patients, 3D TEE proved superior to 2D TEE for providing sufficient information (96 vs. 48 %, P = 0.002). Procedural success was obtained in 26 patients (96.3 %), without complications. Transcatheter closure of multiple ASDs under 3D TEE guidance is effective and safe. Real-time 3D TEE can provide useful information regarding complex ASD morphology. It can thus contribute to developing a successful treatment strategy, especially in patients with three or more defects.
Collapse
|
12
|
Percutaneous retrieval of an Amplatzer septal occluder device that had migrated to the aortic arch. Cardiovasc Intervent Radiol 2012; 35:430-3. [PMID: 21431972 DOI: 10.1007/s00270-011-0139-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
13
|
Seca L, Cação R, Silva J, Providência R, Mota P, Costa M, Leitão Marques A. Intracardiac echocardiography imaging for device closure of atrial septal defects—A single-center experience. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2012. [DOI: 10.1016/j.repce.2011.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
14
|
[Intracardiac echocardiography imaging for device closure of atrial septal defects--a single-center experience]. Rev Port Cardiol 2012; 31:407-12. [PMID: 22579835 DOI: 10.1016/j.repc.2011.11.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Accepted: 11/30/2011] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION Device closure of interatrial communications has become a well-established technique to treat left-to-right shunt associated with atrial septal defect (ASD) and to prevent paradoxical embolism in patients with patent foramen ovate (PFO). Guidance by transesophageal echocardiography (TEE) is the standard practice but intracardiac echocardiography (ICE) is a feasible and safe alternative for monitoring these procedures. OBJECTIVES To report our experience in the percutaneous closure of ASD and PFO guided by ICE. METHODS We retrospectively reviewed all patients with ASD or PFO who underwent percutaneous closure guided exclusively by ICE between January 2008 and December 2010. All patients were followed clinically with regular echocardiographic evaluation (at discharge, one month, three, six and twelve months) to exclude residual shunt and device malposition. RESULTS A total of 127 patients (mean age 46.6 +/- 12.2 years; 71% female) underwent transcatheter device closure of ASD or PFO during the study period. Device deployment with ICE monitoring was 100% successful, with a low rate of complications and eliminating the need for additional imaging techniques. CONCLUSIONS ICE provides anatomical detail of ASD/PFO and cardiac structures, facilitating congenital cardiac interventional procedures. It eliminates the major drawbacks associated with TEE and enables the interventional cardiologist to control all aspects of the procedure without relying on additional echocardiographic support.
Collapse
|
15
|
Mckay EJ, Ashrafi R, Mckay V, Amadi A. Aneurysmal 'pepper-pot' atrial septal defect in an older gentleman with multiple cerebrovascular attacks. BMJ Case Rep 2012; 2012:bcr.12.2011.5402. [PMID: 22605008 DOI: 10.1136/bcr.12.2011.5402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Our patient presented to a large university teaching hospital with a history of light-headedness, falls and multiple cerebrovascular ischaemic events. This caused a right sided hemiplegia and the patient experienced significant functional limitation. Extensive investigations were carried out to exclude any causative factors such as carotid artery disease and the patient had all identifiable cardiovascular risk factors identified and modified. No significant pathology was found and a referral was made to the cardiology service. Transthoracic echocardiography revealed a complex type 3 perforate 'pepper pot' atrial septal aneurysm with associated thrombus. The patient was commenced on warfarin and appropriate rate limiting medication. After discussion of all interventional modalities, the patient opted for conservative management.
Collapse
Affiliation(s)
- Ewan J Mckay
- Cardiology Department, Royal Oldham Hospital, Manchester, UK.
| | | | | | | |
Collapse
|
16
|
Watanabe N, Taniguchi M, Akagi T, Tanabe Y, Toh N, Kusano K, Ito H, Koide N, Sano S. Usefulness of the right parasternal approach to evaluate the morphology of atrial septal defect for transcatheter closure using two-dimensional and three-dimensional transthoracic echocardiography. J Am Soc Echocardiogr 2012; 25:376-82. [PMID: 22285413 DOI: 10.1016/j.echo.2012.01.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2010] [Indexed: 11/29/2022]
Abstract
BACKGROUND The aim of this study was to demonstrate the feasibility and usefulness of addition of the right parasternal approach to the conventional left parasternal and apical approaches using two-dimensional (2D) and three-dimensional (3D) transthoracic echocardiography (TTE) for morphologic evaluation in cases of transcatheter closure of atrial septal defects (ASDs). METHODS In 112 consecutive patients with ASDs, the morphology of the defects was evaluated for transcatheter closure in the right parasternal view in addition to the conventional left views using 2D and 3D TTE. Measurements of the maximal ASD diameter and detection of deficient rim obtained on 2D TTE were compared with those obtained by 2D transesophageal echocardiography. The shapes and locations of ASDs visualized by 3D TTE were compared with those visualized by 3D transesophageal echocardiography. RESULTS In 88 patients (80.0%), optimal images from the right parasternal approach for morphologic evaluation of ASDs were obtained. Although there was a significant difference in maximal ASD diameter obtained only in the conventional left approach compared with transesophageal echocardiographic measurements (P < .05), when the right parasternal approach was applied, a significant difference was not found (P = .18), and the diagnostic concordance of the rim deficiency was improved from 85.2% to 90.9%. Three-dimensional TTE from the right parasternal approach improved visualization of the shape and location of ASDs from 65.5% to 74.5%. CONCLUSIONS Additional use of the right parasternal approach enables detailed morphologic evaluation for transcatheter closure of ASDs. In patients with suboptimal images on 3D TTE in the left conventional approach, additional 3D TTE in the right parasternal approach can improve the feasibility of obtaining optimal 3D images to evaluate the shapes and locations of ASDs.
Collapse
Affiliation(s)
- Nobuhisa Watanabe
- Division of Medical Support, Okayama University Hospital, 2-5-1 Kita-ku Shikata-Cho, Okayama, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Taniguchi M, Akagi T. Real-time imaging for transcatheter closure of atrial septal defects. Interv Cardiol 2011. [DOI: 10.2217/ica.11.73] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
18
|
Rigatelli G, Dell' Avvocata F, Cardaioli P, Giordan M, Vassiliev D, Nghia NT, Chen JP. Five-year Follow-up of Intracardiac Echocardiography-assisted Transcatheter Closure of Complex Ostium Secundum Atrial Septal Defect. CONGENIT HEART DIS 2011; 7:103-10. [DOI: 10.1111/j.1747-0803.2011.00567.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Marchante M, Ramos F, Vicente R, Navarro JL, Barberá M. [Postoperative management of postpneumonectomy pulmonary edema in a patient with ostium secundum atrial septal defect]. ACTA ACUST UNITED AC 2011; 58:251-3. [PMID: 21608282 DOI: 10.1016/s0034-9356(11)70048-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We report the case of a 55-year-old woman who underwent right pneumonectomy for invasive squamous cell carcinoma. At 48 hours after surgery she developed severe dyspnea and hypoxemia that required reintubation and a progressively higher inspired oxygen fraction. A radiograph demonstrated pulmonary edema; echocardiography revealed an ostium secundum atrial septal defect with increased flow to the lung and severe pulmonary hypertension. Emergency percutaneous closure of this defect was carried out. This case report describes the management and treatment of postpneumonectomy pulmonary edema and atrial septal defect, as well as the circumstances that favor their development. We recommend that cardiac defects be investigated and possible treatment be considered prior to pneumonectomy.
Collapse
Affiliation(s)
- M Marchante
- Servicio de Anestesia y Reanimación, Hospital la Fe de Valencia.
| | | | | | | | | |
Collapse
|
20
|
Patent oval foramen transcatheter closure: results of a strategy based on tailoring the device to the specific patient's anatomy. Cardiol Young 2010; 20:144-9. [PMID: 20219151 DOI: 10.1017/s1047951109990631] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Usually the literature results for device-closure of patent oval foramen concern a single type of device or different devices implanted without anatomical preferences. We propose a strategy of device type and selection based on intra-cardiac echocardiography measurements of inter-atrial septum characteristics. METHODS We prospectively enrolled 100 consecutive patients with a mean age of 43 plus or minus 15.5 years, 68 females, who had been referred to our centre for catheter-based closure of inter-atrial shunts over a 48-month period. On the basis of intra-cardiac echocardiography findings the operators selected the Amplatzer Occluder family (AGA Medical Corporation) or the Premere Closure System (St Jude Medical Inc.). Determinants of the selection process were presence and extension of atrial septal aneurysm, tunnel length, rims length, and thickness, presence of additional fenestrations. RESULTS According on intra-cardiac echocardiography study, 26 patients have a long channel patent oval foramen, 44 patients had a large atrial septal aneurysm (more than four RL), 24 patients had a moderate atrial septal aneurysm (more than two RL but less than four right-to-left), and six patients had hypertrophic rims. Thus, the Amplatzer PFO Occluder was selected in 24 patients, the Amplatzer ASD Cribriform Occluder in 44 patients, and the Premere device in 32 cases. No aortic erosions, device thrombosis, or recurrent ischaemic cerebral events were observed. Pre-discharge and follow-up occlusion rates were 91% and 96%, respectively. CONCLUSIONS Our study suggested that such strategy driven from identification and measurements of the right atrium and inter-atrial septum components resulted in low complications and high-success rates, mandatory conditions when facing with otherwise healthy subjects, such as the patients with patent oval foramen.
Collapse
|
21
|
Rigatelli G, Dell'Avvocata F, Giordan M, Ronco F, Braggion G, Schenal N, Aggio S, Cardaioli P. Transcatheter patent foramen ovale closure in spite of interatrial septum hypertrophy or lipomatosis: a case series. J Cardiovasc Med (Hagerstown) 2010; 11:91-5. [PMID: 19829139 DOI: 10.2459/jcm.0b013e32832f4046] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Hypertrophy and lipomatosis of the interatrial septum have been thought to be contraindications for transcatheter patent foramen ovale (PFO) and atrial septal defect closure because of the limits of current devices and the risk of suboptimal results. No reports have been produced yet about PFO closure in patients with such conditions. We retrospectively assessed the safety and effectiveness of PFO closure in patients with hypertrophy or lipomatosis of fossa ovalis rims. METHODS We searched our database of 140 consecutive patients (mean age 43 +/- 15. 5 years, 98 female patients) who underwent transcatheter PFO closure for cases of hypertrophy or lipomatosis of the interatrial septum. All patients were screened with transesophageal echocardiography before the operation. All patients underwent intracardiac echocardiography study and attempted closure. RESULTS Ten patients (7.1%) underwent an attempt at transcatheter closure in the presence of hypertrophy of the rims (eight patients) or lipomatosis (two patients). All patients were aged more than 50 years and has multiple recurrent stroke events (nine patients) or need for a posterior cerebral surgical procedure (one patient) making closure mandatory. After intracardiac echocardiography study and measurements, two 25 mm Amplatzer and eight 25 mm Premere Occlusion System devices have been implanted successfully. On mean follow-up of 36.6 +/- 14.8 months, two patients had a small residual shunt: no recurrence of stroke or aortic erosion or device thrombosis was observed during this period. CONCLUSION Transcatheter PFO closure in the presence of hypertrophy or lipomatosis of fossa ovalis rims is not contraindicated per se: careful evaluation of rim thickness with intracardiac echocardiography and selection of soft and asymmetrically opening devices may allow for a safe and effective PFO closure, at least in patients with no severe atrial septal aneurysm.
Collapse
Affiliation(s)
- Gianluca Rigatelli
- Section of Adult Congenital and Adult Heart Disease, Cardiovascular Diagnosis and Endoluminal Interventions, Rovigo General Hospital, Rovigo, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Rigatelli G, Cardaioli P, Giordan M, Dell'Avvocata F, Braggion G, Piergentili C, Roncon L, Faggian G. Transcatheter Intracardiac Echocardiography-Assisted Closure of Interatrial Shunts: Complications and Midterm Follow-Up. Echocardiography 2009; 26:196-202. [DOI: 10.1111/j.1540-8175.2008.00763.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
23
|
Highly fenestrated septum primum leads to failure of Amplatzer septal defect closure. Ann Thorac Surg 2008; 86:998-1000. [PMID: 18721601 DOI: 10.1016/j.athoracsur.2008.02.077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2008] [Revised: 02/21/2008] [Accepted: 02/25/2008] [Indexed: 11/21/2022]
Abstract
A patient presenting with a history of transient ischemic attacks was initially diagnosed with a large secundum-type atrial septal defect by transesophageal echocardiography. Subsequent attempts to percutaneously repair the defect using an Amplatzer septal occlude device (AGA Medical, Plymouth, MN) failed to position correctly on multiple attempts. At the time of surgery, a largely deficient and highly fenestrated septum primum was found, which was likely the cause of the Amplatzer device (AGA Medical) failure. The defect was then definitively repaired using a bovine pericardial patch without incident.
Collapse
|
24
|
Rigatelli G, Rigateli G, Cardaioli P, Braggion G, Aggio S, Giordan M, Magro B, Nascimben A, Favaro A, Roncon L, Rincon L. Transesophageal Echocardiography and Intracardiac Echocardiography Differently Predict Potential Technical Challenges or Failures of Interatrial Shunts Catheter-Based Closure. J Interv Cardiol 2007; 20:77-81. [PMID: 17300409 DOI: 10.1111/j.1540-8183.2007.00219.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
We sought to prospectively assess the role of transesophageal (TEE) and intracardiac echocardiography (ICE) in detecting potential technical difficulties or failures in patients submitted to interatrial shunts percutaneous closure. We prospectively enrolled 46 consecutive patients (mean age 35+/-28, 8 years, 30 female) referred to our center for catheter-based closure of interatrial shunts. All patients were screened with TEE before the intervention. Patients who met the inclusion criteria underwent ICE study before the closure attempt (40 patients). TEE detected potential technical difficulties in 22.5% (9/40) patients, whereas ICE detected technical difficulties in 32.5% (13/40 patients). In patients with positive TEE/ICE the procedural success (92.4% versus 100% and, P = ns) and follow-up failure rate (7.7% versus 0%, P = ns) were similar to patients with negative TEE/ICE, whereas the fluoroscopy time (7 +/- 1.2 versus 5 +/- 0.7 minutes, P < 0.03), the procedural time (41 +/- 4.1 versus 30 +/- 8.2 minutes, P +/- 0.03), and technical difficulties rate (23.1% versus 0%, P = 0.013) were higher. Differences between ICE and TEE in the evaluation of rims, measurement of ASD or fossa ovalis, and detection of venous valve and embryonic septal membrane remnants impacted on technical challenges and on procedural and fluoroscopy times but did not influence the success rate and follow-up failure rate.
Collapse
Affiliation(s)
- Gianluca Rigatelli
- Rovigo General Hospital, Interventional Cardiology Unit, 18 Legnago, Verona, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Echocardiography in the Adult with Congenital Heart Disease. CARDIOVASCULAR MEDICINE 2007. [DOI: 10.1007/978-1-84628-715-2_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
26
|
Muñóz-Castellanos L, Espinola-Zavaleta N, Kuri-Nivón M, Ruíz JF, Keirns C. Atrial Septal Defect: Anatomoechocardiographic Correlation. J Am Soc Echocardiogr 2006; 19:1182-9. [PMID: 16950475 DOI: 10.1016/j.echo.2006.04.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2006] [Indexed: 11/16/2022]
Abstract
This study was undertaken to enhance understanding of the anatomic abnormalities involved in atrial septal defect (ASD) based on the anatomoechocardiographic comparison of equivalent specimens of ASD and the echocardiograms of patients with this anomaly. Of the 72 heart specimens, two had common atrioventricular canal (2.8%) and one had absence of right atrioventricular connection (1.4%). In all, 46 (63.8%) had fossa ovalis type ASD, two (2.8%) had true ostium secundum type ASD, two (2.8%) had ostium primum type ASD, two (2.8%) had superior sinus venosus type ASD, and two (2.8%) had inferior sinus venosus type ASD. One (1.4%) specimen had a coronary venous sinus type ASD and 14 (19.4%) had mixed type ASD. Of the 144 patients evaluated with echocardiography 15 (10.4%) had common atrioventricular canal, one (0.7%) had right absence of atrioventricular connection, 105 (72.9%) had ostium secundum type ASD (fossa ovalis), 10 (7%) had mixed type ASD, 9 (6.2%) had superior venous sinus type ASD, two (1.4%) had ostium primum type ASD, and two (1.4%) had true fossa ovalis type ASD. This series leads us to conclude that the key to successful management of ASD depends on understanding echocardiographic images in terms of anatomic specimens to provide appropriate evaluations for therapeutic decisions and establishment of prognoses.
Collapse
Affiliation(s)
- Luis Muñóz-Castellanos
- Outpatient Clinic Echocardiography, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico
| | | | | | | | | |
Collapse
|
27
|
van den Bosch AE, Ten Harkel DJ, McGhie JS, Roos-Hesselink JW, Simoons ML, Bogers AJJC, Meijboom FJ. Characterization of Atrial Septal Defect Assessed by Real-time 3-Dimensional Echocardiography. J Am Soc Echocardiogr 2006; 19:815-21. [PMID: 16762762 DOI: 10.1016/j.echo.2006.01.016] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2005] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to describe a quantitative evaluation by real-time 3-dimensional (3D) echocardiography (RT-3DE) of atrial septal defect (ASD) and atrial septum that is important for patient selection for transcatheter closure, and to assess the reliability of RT-3DE findings compared with operation. METHODS Forty-five patients, who were scheduled for surgical or transcatheter closure of an ASD, were included in the study. RESULTS In 43 patients (96%), 3D reconstructions allowed optimal imaging of the ASD. The correlations between the ASD maximal diameter by RT-3DE and operation or balloon sizing were excellent (r > 0.95). All surrounding rims of the atrial septum could be assessed on 3D reconstruction; except for the aortic rim, a cross-sectional reconstruction was created mimicking the transesophageal echocardiographic cross section (r > 0.92). CONCLUSION RT-3DE allows accurate determination of ASD location, ASD size, and surrounding tissue of the atrial septum, and might replace transesophageal echocardiography for patient selection for surgical or transcatheter closure.
Collapse
|