1
|
Vuong TNAM, Bartolf‐Kopp M, Andelovic K, Jungst T, Farbehi N, Wise SG, Hayward C, Stevens MC, Rnjak‐Kovacina J. Integrating Computational and Biological Hemodynamic Approaches to Improve Modeling of Atherosclerotic Arteries. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307627. [PMID: 38704690 PMCID: PMC11234431 DOI: 10.1002/advs.202307627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 03/12/2024] [Indexed: 05/07/2024]
Abstract
Atherosclerosis is the primary cause of cardiovascular disease, resulting in mortality, elevated healthcare costs, diminished productivity, and reduced quality of life for individuals and their communities. This is exacerbated by the limited understanding of its underlying causes and limitations in current therapeutic interventions, highlighting the need for sophisticated models of atherosclerosis. This review critically evaluates the computational and biological models of atherosclerosis, focusing on the study of hemodynamics in atherosclerotic coronary arteries. Computational models account for the geometrical complexities and hemodynamics of the blood vessels and stenoses, but they fail to capture the complex biological processes involved in atherosclerosis. Different in vitro and in vivo biological models can capture aspects of the biological complexity of healthy and stenosed vessels, but rarely mimic the human anatomy and physiological hemodynamics, and require significantly more time, cost, and resources. Therefore, emerging strategies are examined that integrate computational and biological models, and the potential of advances in imaging, biofabrication, and machine learning is explored in developing more effective models of atherosclerosis.
Collapse
Affiliation(s)
| | - Michael Bartolf‐Kopp
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Kristina Andelovic
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Tomasz Jungst
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
- Department of Orthopedics, Regenerative Medicine Center UtrechtUniversity Medical Center UtrechtUtrecht3584Netherlands
| | - Nona Farbehi
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydney2052Australia
- Tyree Institute of Health EngineeringUniversity of New South WalesSydneyNSW2052Australia
- Garvan Weizmann Center for Cellular GenomicsGarvan Institute of Medical ResearchSydneyNSW2010Australia
| | - Steven G. Wise
- School of Medical SciencesUniversity of SydneySydneyNSW2006Australia
| | - Christopher Hayward
- St Vincent's HospitalSydneyVictor Chang Cardiac Research InstituteSydney2010Australia
| | | | - Jelena Rnjak‐Kovacina
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydney2052Australia
- Tyree Institute of Health EngineeringUniversity of New South WalesSydneyNSW2052Australia
- Australian Centre for NanoMedicine (ACN)University of New South WalesSydneyNSW2052Australia
| |
Collapse
|
2
|
Sonmez F, Karagoz S, Yildirim O, Firat I. Experimental and numerical investigation of the stenosed coronary artery taken from the clinical setting and modeled in terms of hemodynamics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3793. [PMID: 37975163 DOI: 10.1002/cnm.3793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 10/31/2023] [Accepted: 11/05/2023] [Indexed: 11/19/2023]
Abstract
The study was carried out to investigate the effect of the artery with different pulse values and stenosis rates on the pressure drop, the peristaltic pump outlet pressure, fractional flow reserve (FFR) and most importantly the amount of power consumed by the peristaltic pump. For this purpose, images taken from the clinical environment were produced as models (10 mm inlet diameter) with 0% and 70% percent areal stenosis rates (PSR) on a three-dimensional (3D) printer. In the experimental system, pure water was used as the fluid at 54, 84, 114, 132, and 168 bpm pulse values. In addition, computational fluid dynamics (CFD) analyzes of the test region were performed using experimental boundary conditions with the help of ANSYS-Fluent software. The findings showed that as PSR increases in the arteries, the pressure drop in the stenosis region increases and this amount increases dramatically with increasing effort. An increase of approximately 40% was observed in the pump outlet pressure value from 54 bpm to 168 bpm in the PSR 0% model and 51% increase in the PSR 70% model. It has been observed that the pump does more work to overcome the increased pressure difference due to increased pulse rate and PSR. With the effect of contraction, the power consumption of the pump increased from 9.2% for 54 bpm to 13.8% for 168 bpm. In both models, the Wall Shear Stress (WSS) increased significantly. WSS increased abruptly in the stenosis and arcuate regions, while sudden decreases were observed in the flow separation region.
Collapse
Affiliation(s)
- Fatin Sonmez
- Artvin Vocational School, Artvin Coruh University, Artvin, Turkey
| | - Sendogan Karagoz
- Department of Mechanical Engineering, Ataturk University, Erzurum, Turkey
| | - Orhan Yildirim
- Department of Mechanical Engineering, Ataturk University, Erzurum, Turkey
| | - Ilker Firat
- Ilic Dursun Yildirim Vocational School, Erzincan Binali Yildirim University, Erzincan, Turkey
| |
Collapse
|
3
|
Cai Y, Li Z. Mathematical modeling of plaque progression and associated microenvironment: How far from predicting the fate of atherosclerosis? COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 211:106435. [PMID: 34619601 DOI: 10.1016/j.cmpb.2021.106435] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 09/16/2021] [Indexed: 06/13/2023]
Abstract
Mathematical modeling contributes to pathophysiological research of atherosclerosis by helping to elucidate mechanisms and by providing quantitative predictions that can be validated. In turn, the complexity of atherosclerosis is well suited to quantitative approaches as it provides challenges and opportunities for new developments of modeling. In this review, we summarize the current 'state of the art' on the mathematical modeling of the effects of biomechanical factors and microenvironmental factors on the plaque progression, and its potential help in prediction of plaque development. We begin with models that describe the biomechanical environment inside and outside the plaque and its influence on its growth and rupture. We then discuss mathematical models that describe the dynamic evolution of plaque microenvironmental factors, such as lipid deposition, inflammation, smooth muscle cells migration and intraplaque hemorrhage, followed by studies on plaque growth and progression using these modelling approaches. Moreover, we present several key questions for future research. Mathematical models can complement experimental and clinical studies, but also challenge current paradigms, redefine our understanding of mechanisms driving plaque vulnerability and propose future potential direction in therapy for cardiovascular disease.
Collapse
Affiliation(s)
- Yan Cai
- School of Biological Sciences and Medical Engineering, Southeast University, Nanjing 210096, China.
| | - Zhiyong Li
- School of Biological Sciences and Medical Engineering, Southeast University, Nanjing 210096, China; School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD 4001, Australia
| |
Collapse
|
4
|
Athani A, Ghazali NNN, Badruddin IA, Kamangar S, Anqi AE, Algahtani A. Investigation of two-way fluid-structure interaction of blood flow in a patient-specific left coronary artery. Biomed Mater Eng 2021; 33:13-30. [PMID: 34366314 DOI: 10.3233/bme-201171] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The blood flow in the human artery has been a subject of sincere interest due to its prime importance linked with human health. The hemodynamic study has revealed an essential aspect of blood flow that eventually proved to be paramount to make a correct decision to treat patients suffering from cardiac disease. OBJECTIVE The current study aims to elucidate the two-way fluid-structure interaction (FSI) analysis of the blood flow and the effect of stenosis on hemodynamic parameters. METHODS A patient-specific 3D model of the left coronary artery was constructed based on computed tomography (CT) images. The blood is assumed to be incompressible, homogenous, and behaves as Non-Newtonian, while the artery is considered as a nonlinear elastic, anisotropic, and incompressible material. Pulsatile flow conditions were applied at the boundary. Two-way coupled FSI modeling approach was used between fluid and solid domain. The hemodynamic parameters such as the pressure, velocity streamline, and wall shear stress were analyzed in the fluid domain and the solid domain deformation. RESULTS The simulated results reveal that pressure drop exists in the vicinity of stenosis and a recirculation region after the stenosis. It was noted that stenosis leads to high wall stress. The results also demonstrate an overestimation of wall shear stress and velocity in the rigid wall CFD model compared to the FSI model.
Collapse
Affiliation(s)
- Abdulgaphur Athani
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - N N N Ghazali
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Irfan Anjum Badruddin
- Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha, Asir, Kingdom Saudi Arabia.,Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Asir, Kingdom Saudi Arabia
| | - Sarfaraz Kamangar
- Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Asir, Kingdom Saudi Arabia
| | - Ali E Anqi
- Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Asir, Kingdom Saudi Arabia
| | - Ali Algahtani
- Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha, Asir, Kingdom Saudi Arabia.,Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Asir, Kingdom Saudi Arabia
| |
Collapse
|
5
|
Abstract
Atherosclerosis is one of the main causes of cardiovascular events, namely, myocardium infarction and cerebral stroke, responsible for a great number of deaths every year worldwide. This pathology is caused by the progressive accumulation of low-density lipoproteins, cholesterol, and other substances on the arterial wall, narrowing its lumen. To date, many hemodynamic studies have been conducted experimentally and/or numerically; however, this disease is not yet fully understood. For this reason, the research of this pathology is still ongoing, mainly, resorting to computational methods. These have been increasingly used in biomedical research of atherosclerosis because of their high-performance hardware and software. Taking into account the attempts that have been made in computational techniques to simulate realistic conditions of blood flow in both diseased and healthy arteries, the present review aims to give an overview of the most recent numerical studies focused on coronary arteries, by addressing the blood viscosity models, and applied physiological flow conditions. In general, regardless of the boundary conditions, numerical studies have been contributed to a better understanding of the development of this disease, its diagnosis, and its treatment.
Collapse
|
6
|
Kamangar S, Anjum Badruddin I, Anqi AE, Ahamed Saleel C, Tirth V, Yunus Khan T, Anas Khan M, Mallick Z, Salman Ahmed N. Influence of bifurcation angle in left coronary artery with stenosis: A CFD analysis. Biomed Mater Eng 2020; 31:339-349. [DOI: 10.3233/bme-201107] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: The left coronary artery commonly known as LCA gets divided into two branches, such as the left circumflex (LCX) and left anterior descending (LAD) at a particular angle. This angle is varies from person to person. The present computational study contributes remarkable expertise about the influence of this angle variation on the hemodynamic parameters in the presence of 80% area stenosis at the LAD branch. OBJECTIVE: This study aimed to compare the effect of the bifurcation angle on hemodynamic parameters in the left coronary artery with 80% stenosis. METHOD: Computational models of left coronary bifurcation angles of 30°, 60°, 90°, 120° were developed to understand the flow behavior of left coronary artery branches. The 80% area stenosis (AS) is considered at the LAD branch immediate to bifurcation. RESULTS: Measurements of pressure, velocity and wall shear stress were carried out corresponding to various bifurcation angles. It was found that the drop-in pressure increases as the angle increases from narrow to wider. A slight elevation in the velocity at the stenosis was observed. In addition, the obtained results further reveal a recirculation region immediately after the plaque, which leads to more deposition of plaque in the flow obstructed area. It is known that the shear stress at the arterial wall across the stenosis increases as the angle of bifurcation increases from narrow to wider. CONCLUSIONS: The bifurcation of the left coronary artery and size of the stenosis have a notable impact on the pressure and wall shear stress. These two factors should be given due consideration by cardiologists to assess the complexity of stenosis in the LCA branches.
Collapse
Affiliation(s)
| | | | - Ali E. Anqi
- , King Khalid University, , Kingdom of Saudi Arabia
| | | | - Vineet Tirth
- , King Khalid University, , Kingdom of Saudi Arabia
| | | | | | - Z. Mallick
- , King Khalid University, , Kingdom of Saudi Arabia
| | | |
Collapse
|
7
|
Pandey R, Kumar M, Srivastav VK. Numerical computation of blood hemodynamic through constricted human left coronary artery: Pulsatile simulations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105661. [PMID: 32738679 DOI: 10.1016/j.cmpb.2020.105661] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 07/10/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE The accumulation of plaque in the coronary artery of the human heart restricts the path of blood flow in that region and leads to Coronary Artery Disease. This study's goal is to present the pulsatile blood flow conduct through four different levels of constrictions, i.e., healthy, 25%, 50%, and 75% in human left coronary arteries. METHODS Using CT scan data of a healthy person, the two-dimensional coronary model is constructed. A non-Newtonian Carreau model is used to study the maximum flow velocity, streamline effect, and maximum Wall Shear Stress at the respective constricted areas over the entire cardiac cycle. Finite Volume Method is executed for solving the governing equations. The fluctuating Wall Shear Stress (WSS) at different levels was assessed using Computational Fluid Dynamics (CFD). RESULTS The comparative study of the diseased arteries showcases that at the systolic phase, the 75% blocked artery attains the maximum velocity of 0.14 m/s and 0.53 m/s at t=0.005 s and t=0.115 s, respectively. While the maximum velocity takes a significant drop at t=0.23 s and t=0.345 s, this marks the diastolic phase. The streamline contour showcased the blood flow conduct at different phases of the cardiac cycle. At the peak systolic phase, a dense flow separation was observed near the blocked regions. It highlights the disturbed flow in that particular region. The most severely diseased artery acquires the maximum WSS of 18.81 Pa at the peak systolic phase, i.e., at t=0.115 s. CONCLUSIONS The computational study of the hemodynamic parameters can aid in the early anticipation of the degree of the severity of the diseased arteries. This study, in a way, could benefit doctors/surgeons to plan an early treatment/surgery on the grounds of the severity of the disease. Thus, a before time prognosis could restrain the number of deaths caused due to Coronary Artery Disease.
Collapse
Affiliation(s)
- Rupali Pandey
- Department of Mathematics, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, U.P. 211004, India
| | - Manoj Kumar
- Department of Mathematics, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, U.P. 211004, India
| | - Vivek Kumar Srivastav
- Department of Mathematics and Computing, Motihari College of Engineering Motihari, Bihar, India.
| |
Collapse
|
8
|
Bahrami S, Norouzi M. Hemodynamic impacts of hematocrit level by two-way coupled FSI in the left coronary bifurcation. Clin Hemorheol Microcirc 2020; 76:9-26. [DOI: 10.3233/ch-200854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Cardiovascular disease is now under the influence of several factors that encourage researchers to investigate the flow of these vessels. Oscillation influences the blood circulation in the volume of red blood cells (RBC) strongly. Therefore, in this study, its effects have been considered on hemodynamic parameters in the elastic wall and coronary bifurcation. In this study, a 3D geometry of non-Newtonian and pulsatile blood circulation is considered in the left coronary artery bifurcation. The Casson model with various hematocrits is analyzed in elastic and rigid walls. The wall shear stress (WSS) cannot show the stenosis artery alone, therefore, the oscillatory shear index (OSI) is represented as a hemodynamic parameter of WSS individually of time. The results are determined using two-way fluid-structure interaction (FSI) coupling method using an arbitrary Lagrangian-Eulerian method. The most prominent difference in velocity happened in the bifurcation and at hematocrit 30 with yield stress 6.59E-04 Pa. The backflow and vortex flow in the LCx branch grown with increasing shear rates. The likelihood of plaque generation at the ending of the LM branch is observed in hematocrits 10 and 20, while the WSS magnitude is normal in the hematocrit 60 with the greatest yield stress in the bifurcation. The shear stress among the rigid and elastic models is the highest at the ending of the LM branch. The wall shear stress magnitude among the models decreased at most of 24.49% by dividing the flow. Time-independent results for models showed that there is the highest value of OSI at the bifurcation, which then quickly dropped.
Collapse
Affiliation(s)
- Saeed Bahrami
- Faculty of Mechanical Engineering, Shahrood University of Technology, Shahrood, Semnan, Iran
| | - Mahmood Norouzi
- Faculty of Mechanical Engineering, Shahrood University of Technology, Shahrood, Semnan, Iran
| |
Collapse
|
9
|
3D Printed Biomodels for Flow Visualization in Stenotic Vessels: An Experimental and Numerical Study. MICROMACHINES 2020; 11:mi11060549. [PMID: 32485816 PMCID: PMC7344925 DOI: 10.3390/mi11060549] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 05/17/2020] [Accepted: 05/25/2020] [Indexed: 12/13/2022]
Abstract
Atherosclerosis is one of the most serious and common forms of cardiovascular disease and a major cause of death and disability worldwide. It is a multifactorial and complex disease that promoted several hemodynamic studies. Although in vivo studies more accurately represent the physiological conditions, in vitro experiments more reliably control several physiological variables and most adequately validate numerical flow studies. Here, a hemodynamic study in idealized stenotic and healthy coronary arteries is presented by applying both numerical and in vitro approaches through computational fluid dynamics simulations and a high-speed video microscopy technique, respectively. By means of stereolithography 3D printing technology, biomodels with three different resolutions were used to perform experimental flow studies. The results showed that the biomodel printed with a resolution of 50 μm was able to most accurately visualize flow due to its lowest roughness values (Ra = 1.8 μm). The flow experimental results showed a qualitatively good agreement with the blood flow numerical data, providing a clear observation of recirculation regions when the diameter reduction reached 60%.
Collapse
|
10
|
Bahrami S, Norouzi M. A numerical study on hemodynamics in the left coronary bifurcation with normal and hypertension conditions. Biomech Model Mechanobiol 2018; 17:1785-1796. [DOI: 10.1007/s10237-018-1056-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Accepted: 07/12/2018] [Indexed: 12/29/2022]
|
11
|
Measurement of coronary bifurcation angle with coronary CT angiography: A phantom study. Phys Med 2018; 45:198-204. [DOI: 10.1016/j.ejmp.2017.09.137] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 09/19/2017] [Accepted: 09/25/2017] [Indexed: 01/20/2023] Open
|
12
|
Sun Z, Chaichana T. An investigation of correlation between left coronary bifurcation angle and hemodynamic changes in coronary stenosis by coronary computed tomography angiography-derived computational fluid dynamics. Quant Imaging Med Surg 2017; 7:537-548. [PMID: 29184766 DOI: 10.21037/qims.2017.10.03] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background To investigate the correlation between left coronary bifurcation angle and coronary stenosis as assessed by coronary computed tomography angiography (CCTA)-generated computational fluid dynamics (CFD) analysis when compared to the CCTA analysis of coronary lumen stenosis and plaque lesion length with invasive coronary angiography (ICA) as the reference method. Methods Thirty patients (22 males, mean age: 59±6.9 years) with calcified plaques at the left coronary artery were included in the study with all patients undergoing CCTA and ICA examinations. CFD simulation was performed to analyze hemodynamic changes to the left coronary artery models in terms of wall shear stress, wall pressure and flow velocity, with findings correlated to the coronary stenosis and degree of bifurcation angle. Calcified plaque length was measured in the left coronary artery with diagnostic value compared to that from coronary lumen and bifurcation angle assessments. Results Of 26 significant stenosis at left anterior descending (LAD) and 13 at left circumflex (LCx) on CCTA, only 14 and 5 of them were confirmed to be >50% stenosis at LAD and LCx respectively on ICA, resulting in sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 100%, 52%, 49% and 100%. The mean plaque length was measured 5.3±3.6 and 4.4±1.9 mm at LAD and LCx, respectively, with diagnostic sensitivity, specificity, PPV and NPV being 92.8%, 46.7%, 61.9% and 87.5% for extensively calcified plaques. The mean bifurcation angle was measured 83.9±13.6º and 83.8±13.3º on CCTA and ICA, respectively, with no significant difference (P=0.98). The corresponding sensitivity, specificity, PPV and NPV were 100%, 78.6%, 84.2% and 100% based on bifurcation angle measurement on CCTA, 100%, 73.3%, 78.9% and 100% based on bifurcation angle measurements on ICA, respectively. Wall shear stress was noted to increase in the LAD and LCx models with significant stenosis and wider angulation (>80º), but demonstrated little or no change in most of the coronary models with no significant stenosis and narrower angulation (<80º). Conclusions This study further clarifies the relationship between left coronary bifurcation angle and significant stenosis, with angulation measurement serving as a more accurate approach than coronary lumen assessment or plaque lesion length for determining significant coronary stenosis. Left coronary bifurcation angle is suggested to be incorporated into coronary artery disease (CAD) assessment when diagnosing significant CAD.
Collapse
Affiliation(s)
- Zhonghua Sun
- Department of Medical Radiation Sciences, Curtin University, Perth, Australia
| | - Thanapong Chaichana
- Department of Mathematics and Computer Science, Liverpool Hope University, Liverpool, England, UK
| |
Collapse
|
13
|
Kamangar S, Badruddin IA, Ameer Ahamad N, Soudagar MEM, Govindaraju K, Nik-Ghazali N, Salman Ahmed N, Yunus Khan T. Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery. Biomed Mater Eng 2017; 28:257-266. [DOI: 10.3233/bme-171672] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Sarfaraz Kamangar
- Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Irfan Anjum Badruddin
- Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - N. Ameer Ahamad
- Mathematics Department, Faculty of Science, University of Tabuk, Saudi Arabia
| | | | - Kalimuthu Govindaraju
- Department of Mechanical and Industrial Engineering, Mekelle University, Mekelle, Ethiopia
| | - N. Nik-Ghazali
- Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - N.J. Salman Ahmed
- Department of Mechanical and Industrial Engineering, Sultan Qaboos University, Al Khoud, Muscat, 123, Oman
| | - T.M. Yunus Khan
- Department of Mechanical Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia
| |
Collapse
|
14
|
Pagiatakis C, Tardif JC, L'Allier PL, Mongrain R. Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study. Med Biol Eng Comput 2017; 55:2079-2095. [PMID: 28500478 DOI: 10.1007/s11517-017-1653-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 04/25/2017] [Indexed: 01/10/2023]
Abstract
Interventional cardiologists still rely heavily on angiography for the evaluation of coronary lesion severity, despite its poor correlation with the presence of ischemia. In order to improve the accuracy of the current diagnostic procedures, an understanding of the relative influence of geometric characteristics on the induction of ischemia is required. This idea is especially important for coronary bifurcation lesions (CBLs), whose treatment is complex and is associated with high rates of peri- and post-procedural clinical events. Overall, it is unclear which geometric and morphological parameters of CBLs influence the onset of ischemia. More specifically, the effect of stenosis eccentricity is unknown. Computational fluid dynamic simulations, under a geometric multiscale framework, were executed for seven CBL configurations within the left main coronary artery bifurcation. Both concentric and eccentric stenosis profiles of mild to severe constriction were considered. By using a geometric multiscale framework, the fractional flow reserve, which is the gold-standard clinical diagnostic index, could be calculated and was compared between the eccentric and concentric profiles for each case. The results suggested that for configurations where the supplying vessel is stenosed, eccentricity could have a notable effect on and therefore be an important factor that influences configuration functionality.
Collapse
Affiliation(s)
- Catherine Pagiatakis
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada. .,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.
| | - Jean-Claude Tardif
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Philippe L L'Allier
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Rosaire Mongrain
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada.,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada
| |
Collapse
|
15
|
Qin Y, Wu J, Hu Q, Ghista DN, Wong KKL. Computational evaluation of smoothed particle hydrodynamics for implementing blood flow modelling through CT reconstructed arteries. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2017; 25:213-232. [PMID: 28234274 DOI: 10.3233/xst-17255] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Simulation of blood flow in a stenosed artery using Smoothed Particle Hydrodynamics (SPH) is a new research field, which is a particle-based method and different from the traditional continuum modelling technique such as Computational Fluid Dynamics (CFD). Both techniques harness parallel computing to process hemodynamics of cardiovascular structures. The objective of this study is to develop and test a new robust method for comparison of arterial flow velocity contours by SPH with the well-established CFD technique, and the implementation of SPH in computed tomography (CT) reconstructed arteries. The new method was developed based on three-dimensional (3D) straight and curved arterial models of millimeter range with a 25% stenosis in the middle section. In this study, we employed 1,000 to 13,000 particles to study how the number of particles influences SPH versus CFD deviation for blood-flow velocity distribution. Because further increasing the particle density has a diminishing effect on this deviation, we have determined a critical particle density of 1.45 particles/mm2 based on Reynolds number (Re = 200) at the inlet for an arterial flow simulation. Using this critical value of particle density can avoid unnecessarily big computational expenses that have no further effect on simulation accuracy. We have particularly shown that the SPH method has a big potential to be used in the virtual surgery system, such as to simulate the interaction between blood flow and the CT reconstructed vessels, especially those with stenosis or plaque when encountering vasculopathy, and for employing the simulation results output in clinical surgical procedures.
Collapse
Affiliation(s)
- Yi Qin
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Xili Nanshan, Shenzhen, China
| | - Jianhuang Wu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Xili Nanshan, Shenzhen, China
| | - Qingmao Hu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Xili Nanshan, Shenzhen, China
| | - Dhanjoo N Ghista
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Xili Nanshan, Shenzhen, China
| | - Kelvin K L Wong
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Xili Nanshan, Shenzhen, China
- School of Medicine, University of Western Sydney, NSW, Australia
| |
Collapse
|
16
|
Kamangar S, Badruddin IA, Govindaraju K, Nik-Ghazali N, Badarudin A, Viswanathan GN, Ahmed NJS, Khan TMY. Patient-specific 3D hemodynamics modelling of left coronary artery under hyperemic conditions. Med Biol Eng Comput 2016; 55:1451-1461. [DOI: 10.1007/s11517-016-1604-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Accepted: 12/01/2016] [Indexed: 11/29/2022]
|
17
|
REN XILI, FU YULIN, QIAO AIKE. INFLUENCE OF BIFURCATION DIAMETER ON THE VERTEBRAL ARTERY ORIGIN STENOSIS: A SIMULATION STUDY OF HEMODYNAMICS. J MECH MED BIOL 2016. [DOI: 10.1142/s0219519416500792] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The stenosis at the beginning segment of the vertebral artery accounts for the first risk of stroke in the posterior circulation. The extracranial vertebral arteries, especially the proximal ends, have been considered to be the predilection sites of stenosis or occlusion. From the perspective of hemodynamics, the mechanics of vertebral arteries stenosis is still unclear. In this paper, the formation of atherosclerosis in proximal end was concerned from the aspects of the effect of bifurcation diameter. Different models represent different bifurcation diameter. In order to find correlation between bifurcation diameter and WSS we build different models. Three idealized models with the vertebral artery diameter of [Formula: see text][Formula: see text]m (Model A1), [Formula: see text][Formula: see text]m (Model A2) and [Formula: see text][Formula: see text]m (Model A3) respectively and seven realistic models were analyzed by using computational fluid dynamics tools. The area of low wall shear stress (WSS, [Formula: see text] 1.5[Formula: see text]Pa) in the proximal end of vertebral artery extracted at the peak systole in the idealized models were 2.25[Formula: see text]e-7, 8.55[Formula: see text]e-7 and 1.61[Formula: see text]e-6[Formula: see text]m2, respectively. The area of low WSS on the vertebral artery origin of realistic models extracted at the peak systole were 0, 1.18[Formula: see text]e-09, 3.91[Formula: see text]e-07, 1.68[Formula: see text]e-07, 5.46[Formula: see text]e-06, 1.16[Formula: see text]e-06 and 2.25[Formula: see text]e-06[Formula: see text]m2, respectively. Moreover, the time-averaged WSSs of the three idealized models were 3.95, 3.56 and 3.19, respectively. The time-averaged WSSs of the realistic models were 6.28, 6.36, 4.48, 4.71, 3.59, 3.59 and 3.31[Formula: see text]Pa, respectively. With the increase of bifurcation diameter, the risk of endothelial dysfunction increases, and the same is to intimal hyperplasia.
Collapse
Affiliation(s)
- XILI REN
- College of Life Science and Bioengineering, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing 100124, P. R. China
| | - YULIN FU
- College of Life Science and Bioengineering, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing 100124, P. R. China
| | - AIKE QIAO
- College of Life Science and Bioengineering, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing 100124, P. R. China
| |
Collapse
|
18
|
Giannopoulos AA, Chatzizisis YS, Maurovich-Horvat P, Antoniadis AP, Hoffmann U, Steigner ML, Rybicki FJ, Mitsouras D. Quantifying the effect of side branches in endothelial shear stress estimates. Atherosclerosis 2016; 251:213-218. [PMID: 27372207 DOI: 10.1016/j.atherosclerosis.2016.06.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 06/08/2016] [Accepted: 06/22/2016] [Indexed: 11/25/2022]
Abstract
BACKGROUND AND AIMS Low and high endothelial shear stress (ESS) is associated with coronary atherosclerosis progression and high-risk plaque features. Coronary ESS is currently assessed via computational fluid dynamic (CFD) simulation of coronary blood flow in the lumen geometry determined from invasive imaging such as intravascular ultrasound and optical coherence tomography. This process typically omits side branches of the target vessel in the CFD model as invasive imaging of those vessels is not usually clinically-indicated. The purpose of this study was to determine the extent to which this simplification affects the determination of those regions of the coronary endothelium subjected to pathologic ESS. METHODS We determined the diagnostic accuracy of ESS profiling without side branches to detect pathologic ESS in the major coronary arteries of 5 hearts imaged ex vivo with computed tomography angiography (CTA). ESS of the three major coronary arteries was calculated both without (test model), and with (reference model) inclusion of all side branches >1.5 mm in diameter, using previously-validated CFD approaches. Diagnostic test characteristics (accuracy, sensitivity, specificity and negative and positive predictive value [NPV/PPV]) with respect to the reference model were assessed for both the entire length as well as only the proximal portion of each major coronary artery, where the majority of high-risk plaques occur. RESULTS Using the model without side branches overall accuracy, sensitivity, specificity, NPV and PPV were 83.4%, 54.0%, 96%, 95.9% and 55.1%, respectively to detect low ESS, and 87.0%, 67.7%, 90.7%, 93.7% and 57.5%, respectively to detect high ESS. When considering only the proximal arteries, test characteristics differed for low and high ESS, with low sensitivity (67.7%) and high specificity (90.7%) to detect low ESS, and low sensitivity (44.7%) and high specificity (95.5%) to detect high ESS. CONCLUSIONS The exclusion of side branches in ESS vascular profiling studies greatly reduces the ability to detect regions of the major coronary arteries subjected to pathologic ESS. Single-conduit models can in general only be used to rule out pathologic ESS.
Collapse
Affiliation(s)
- Andreas A Giannopoulos
- Applied Imaging Science Laboratory, Radiology Department, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Pal Maurovich-Horvat
- MTA-SE Lendület Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Antonios P Antoniadis
- Cardiovascular Division, Brigham and Women's Hospital, Boston, MA, USA; Cardiovascular Department, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Udo Hoffmann
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Michael L Steigner
- Applied Imaging Science Laboratory, Radiology Department, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Frank J Rybicki
- Applied Imaging Science Laboratory, Radiology Department, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA; Department of Radiology, The Ottawa Hospital, The University of Ottawa, Ontario, ON, Canada
| | - Dimitrios Mitsouras
- Applied Imaging Science Laboratory, Radiology Department, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
19
|
Coronary computed tomography angiography investigation of the association between left main coronary artery bifurcation angle and risk factors of coronary artery disease. Int J Cardiovasc Imaging 2016; 32 Suppl 1:129-37. [DOI: 10.1007/s10554-016-0884-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 03/24/2016] [Indexed: 10/22/2022]
|
20
|
Wang H, Liu J, Zheng X, Rong X, Zheng X, Peng H, Silber-Li Z, Li M, Liu L. Three-dimensional virtual surgery models for percutaneous coronary intervention (PCI) optimization strategies. Sci Rep 2015; 5:10945. [PMID: 26042609 PMCID: PMC4455241 DOI: 10.1038/srep10945] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Accepted: 05/11/2015] [Indexed: 12/03/2022] Open
Abstract
Percutaneous coronary intervention (PCI), especially coronary stent implantation, has been shown to be an effective treatment for coronary artery disease. However, in-stent restenosis is one of the longstanding unsolvable problems following PCI. Although stents implanted inside narrowed vessels recover normal flux of blood flows, they instantaneously change the wall shear stress (WSS) distribution on the vessel surface. Improper stent implantation positions bring high possibilities of restenosis as it enlarges the low WSS regions and subsequently stimulates more epithelial cell outgrowth on vessel walls. To optimize the stent position for lowering the risk of restenosis, we successfully established a digital three-dimensional (3-D) model based on a real clinical coronary artery and analysed the optimal stenting strategies by computational simulation. Via microfabrication and 3-D printing technology, the digital model was also converted into in vitro microfluidic models with 3-D micro channels. Simultaneously, physicians placed real stents inside them; i.e., they performed “virtual surgeries”. The hydrodynamic experimental results showed that the microfluidic models highly inosculated the simulations. Therefore, our study not only demonstrated that the half-cross stenting strategy could maximally reduce restenosis risks but also indicated that 3-D printing combined with clinical image reconstruction is a promising method for future angiocardiopathy research.
Collapse
Affiliation(s)
- Hujun Wang
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China.,Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| | - Jinghua Liu
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Xu Zheng
- State key laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
| | - Xiaohui Rong
- Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| | - Xuwei Zheng
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Hongyu Peng
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing 100029, China
| | - Zhanghua Silber-Li
- State key laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
| | - Mujun Li
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Liyu Liu
- Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
| |
Collapse
|
21
|
Wu J, Liu G, Huang W, Ghista DN, Wong KKL. Transient blood flow in elastic coronary arteries with varying degrees of stenosis and dilatations: CFD modelling and parametric study. Comput Methods Biomech Biomed Engin 2014; 18:1835-45. [PMID: 25398021 DOI: 10.1080/10255842.2014.976812] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
In this paper, we have analysed pulsatile flow through partially occluded elastic arteries, to determine the haemodynamic parameters of wall shear stress (WSS), wall pressure gradient and pressure drops (ΔP), contributing to enhanced flow resistance and myocardial ischaemic regions which impair cardiac contractility and cause increased work load on the heart. In summary, it can be observed that stenoses in an artery significantly influence the haemodynamic parameters of wall shear stress and pressure drop in contrast to dilatations case. This deduces that stenosis plays a more critical role in plaque growth and vulnerability in contrast to dilatation, and should be the key element in cardiovascular pathology and diagnosis. Through quantitative analysis of WSS and ΔP, we have provided a clearer insight into the haemodynamics of atherosclerotic arteries. Determination of these parameters can be helpful to cardiologists, because it is directly implicated in the genesis and development of atherosclerosis.
Collapse
Affiliation(s)
- Jianhuang Wu
- a Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences , 1068 Xueyuan Boulevard, Xili Nanshan, Shenzhen 518055 , P.R. China
| | | | | | | | | |
Collapse
|
22
|
The study on hemodynamic effect of varied support models of BJUT-II VAD on coronary artery: a primary CFD study. ASAIO J 2014; 60:643-51. [PMID: 25373559 DOI: 10.1097/mat.0000000000000137] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
BJUT-II VAD (Beijing University of Technology ventricular assist device II) is a novel left ventricular assist device. Because of the special connection between the pump and native heart, the hemodynamic effects of BJUT-II VAD on coronary artery are still unclear. Hence, numerical simulations have been conducted to clarify changes in hemodynamic effects of different support modes. A patient-specific left coronary arterial geometric model is reconstructed based on the computed tomography (CT) data. Three support modes, "constant speed mode," "co-pulse mode," and "counter pulse mode," are used in this study. The wall shear stress (WSS), wall shear stress gradient (WSSG), cycle-averaged wall shear stress (avWSS), oscillatory shear index (OSI), and the flow pattern are calculated to evaluate the hemodynamic states of coronary artery. The computational results demonstrate that the hemodynamic states of coronary artery are directly affected by the support modes. The co-pulse modes could achieve the highest blood perfusion (constant speed: 153 ml/min vs. co-pulse: 775 ml/min vs. counter pulse: 140 ml/min) and the highest avWSS (constant speed: 18.1 Pa vs. co-pulse: 42.6 Pa vs. counter pulse: 22.6 Pa). In addition, both the WSS and WSSG at the time of peak blood velocity under the constant speed mode are lower than those under other two support modes. In contrast, the counter pulse mode generates the highest OSI value (constant speed: 0.365 vs. co-pulse: 0.379 vs. counter pulse: 0.426). BJUT-II VAD under co-pulse mode may have benefits for improving coronary perfusion and preventing the development of atherosclerosis; however, the constant speed mode may have benefit for preventing the development of plaque vulnerability.
Collapse
|
23
|
Sun Z, Xu L. Computational fluid dynamics in coronary artery disease. Comput Med Imaging Graph 2014; 38:651-63. [PMID: 25262321 DOI: 10.1016/j.compmedimag.2014.09.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2014] [Revised: 08/22/2014] [Accepted: 09/03/2014] [Indexed: 01/01/2023]
Abstract
Computational fluid dynamics (CFD) is a widely used method in mechanical engineering to solve complex problems by analysing fluid flow, heat transfer, and associated phenomena by using computer simulations. In recent years, CFD has been increasingly used in biomedical research of coronary artery disease because of its high performance hardware and software. CFD techniques have been applied to study cardiovascular haemodynamics through simulation tools to predict the behaviour of circulatory blood flow in the human body. CFD simulation based on 3D luminal reconstructions can be used to analyse the local flow fields and flow profiling due to changes of coronary artery geometry, thus, identifying risk factors for development and progression of coronary artery disease. This review aims to provide an overview of the CFD applications in coronary artery disease, including biomechanics of atherosclerotic plaques, plaque progression and rupture; regional haemodynamics relative to plaque location and composition. A critical appraisal is given to a more recently developed application, fractional flow reserve based on CFD computation with regard to its diagnostic accuracy in the detection of haemodynamically significant coronary artery disease.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Western Australia 6845, Australia.
| | - Lei Xu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|
24
|
SARIFUDDIN. SIMULATION OF CASSON FLUID FLOW AND HEAT TRANSPORT IN DIFFERENTLY SHAPED STENOSES. J MECH MED BIOL 2014. [DOI: 10.1142/s0219519414500249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The present investigation deals with a mathematical model representing the response of heat transfer to blood streaming through the arteries under stenotic condition. The flowing blood is represented as the suspension of all erythrocytes assumed to be Casson fluid and the arterial wall is considered to be rigid having differently shaped stenoses in its lumen arising from various types of abnormal growth or plaque formation. The governing equations of motion accompanied by the appropriate choice of the boundary conditions are solved numerically by Marker and Cell (MAC) method. The necessary checking for numerical stability has been incorporated into the algorithm for better precision of the results computed. The quantitative analysis carried out finally includes the respective profiles of the flow-field and the temperature along with their individual distributions over the entire arterial segment as well. The key factors like the pressure drop, wall shear stress, flow separation, Nusselt number and streamlines are examined for qualitative insight into the blood flow and heat transport phenomena through arterial stenosis. In conformity with other several existing findings the present simulation predicts that the pressure drop and Nusselt number diminishes with increasing yield stress values, and significant enhancement in values of Nusselt number is observed with increasing severity of the stenosis. However, the effect of the shapes of the stenoses on flow separation cannot be ruled out from the present investigation.
Collapse
Affiliation(s)
- SARIFUDDIN
- Department of Mathematics, Raiganj Surendranath College, Raiganj – 733134, Uttar Dinajpur, W.B., INDIA
| |
Collapse
|
25
|
Sun Z. Coronary CT angiography: Beyond morphological stenosis analysis. World J Cardiol 2013; 5:444-452. [PMID: 24392188 PMCID: PMC3879698 DOI: 10.4330/wjc.v5.i12.444] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Revised: 10/04/2013] [Accepted: 11/19/2013] [Indexed: 02/06/2023] Open
Abstract
Rapid technological developments in computed tomography (CT) imaging technique have made coronary CT angiography an attractive imaging tool in the detection of coronary artery disease. Despite visualization of excellent anatomical details of the coronary lumen changes, coronary CT angiography does not provide hemodynamic changes caused by presence of plaques. Computational fluid dynamics (CFD) is a widely used method in the mechanical engineering field to solve complex problems through analysing fluid flow, heat transfer and associated phenomena by using computer simulations. In recent years, CFD is increasingly used in biomedical research due to high performance hardware and software. CFD techniques have been used to study cardiovascular hemodynamics through simulation tools to assist in predicting the behaviour of circulatory blood flow inside the human body. Blood flow plays a key role in the localization and progression of coronary artery disease. CFD simulation based on 3D luminal reconstructions can be used to analyse the local flow fields and flow profiling due to changes of vascular geometry, thus, identifying risk factors for development of coronary artery disease. The purpose of this article is to provide an overview of the coronary CT-derived CFD applications in coronary artery disease.
Collapse
|