Petoukhova A, Snijder R, Vissers T, Ceha H, Struikmans H. In vivodosimetry in cancer patients undergoing intraoperative radiation therapy. Phys Med Biol 2023; 68:18TR01. [PMID: 37607566 DOI: 10.1088/1361-6560/acf2e4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Accepted: 08/22/2023] [Indexed: 08/24/2023]
Abstract
In vivodosimetry (IVD) is an important tool in external beam radiotherapy (EBRT) to detect major errors by assessing differences between expected and delivered dose and to record the received dose by individual patients. Also, in intraoperative radiation therapy (IORT), IVD is highly relevant to register the delivered dose. This is especially relevant in low-risk breast cancer patients since a high dose of IORT is delivered in a single fraction. In contrast to EBRT, online treatment planning based on intraoperative imaging is only under development for IORT. Up to date, two commercial treatment planning systems proposed intraoperative ultrasound or in-room cone-beam CT for real-time IORT planning. This makes IVD even more important because of the possibility for real-time treatment adaptation. Here, we summarize recent developments and applications of IVD methods for IORT in clinical practice, highlighting important contributions and identifying specific challenges such as a treatment planning system for IORT. HDR brachytherapy as a delivery technique was not considered. We add IVD for ultrahigh dose rate (FLASH) radiotherapy that promises to improve the treatment efficacy, when compared to conventional radiotherapy by limiting the rate of toxicity while maintaining similar tumour control probabilities. To date, FLASH IORT is not yet in clinical use.
Collapse
Affiliation(s)
- Anna Petoukhova
- Haaglanden Medical Centre , Department of Medical Physics, Leidschendam, The Netherlands
| | - Roland Snijder
- Haaglanden Medical Centre , Department of Medical Physics, Leidschendam, The Netherlands
| | - Thomas Vissers
- Haaglanden Medical Centre , Medical Library, Leidschendam, The Netherlands
| | - Heleen Ceha
- Haaglanden Medical Centre , Department of Radiation Oncology, Leidschendam, The Netherlands
| | - Henk Struikmans
- Haaglanden Medical Centre , Department of Radiation Oncology, Leidschendam, The Netherlands
| |
Collapse
|
2
|
Baghani HR, Shiri A, Gholamhosseinian H. Comparing the DNA-damage RBE of intraoperative and conventional electron beams using a hybrid simulation approach. Int J Radiat Biol 2023; 100:46-60. [PMID: 37523649 DOI: 10.1080/09553002.2023.2242931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/17/2023] [Accepted: 07/20/2023] [Indexed: 08/02/2023]
Abstract
PURPOSE Employing electron beam for radiotherapy purposes now has been established as one of the standard cancer treatment modalities. Both dedicated intraoperative and conventional electron beams can be employed in patient irradiation. Due to the differences between accelerating structure and electron beam delivery of dedicated intraoperative radiotherapy (IORT) machines and conventional ones, the initial energy spectra of the produced electron beam by these machines may be different. Accordingly, this study aims to evaluate whether these spectral differences can affect the relevant relative biological effectiveness (RBE) values of intraoperative and conventional electron beams. MATERIALS AND METHODS A hybrid Monte Carlo simulation approach was considered. At first, the head LIAC12 machine (as an IORT accelerator) and Varian 2100C/D (as a conventional accelerator) were simulated by MCNPX code and electron energy spectra at different depths and off-axis distances were scored for two nominal electron energies of 6 and 12 MeV at the field sizes of 6 and 10 cm. Then, the calculated spectra were imported to MCDS code to estimate the induced DNA-damage RBE values. Finally, the obtained RBE values for intraoperative and conventional electron beams were compared together. RESULTS The results showed that the RBE values of the intraoperative electron beam are superior to those obtained for conventional electron beam at the same energy/field size combination. Variations of the depth can regularly affect the RBE value for both conventional and intraoperative electron beams, while no ordered variation trend was observed for RBE with changing the off-axis distance. Variations of electron energy and field size can also influence the RBE value for both types of studied electron beams. CONCLUSIONS From the results, it can be concluded the structural differences between the dedicated IORT and conventional Linacs can lead to distinct initial electron energy spectra for intraoperative and conventional electron beams. These physical differences can finally lead to different RBE values for intraoperative and conventional electron beams at the same energy and field size.
Collapse
Affiliation(s)
| | - Ali Shiri
- Medical Physics Department, Mashhad University of Medical Sciences, Mashhad, Iran
| | | |
Collapse
|
3
|
Nakamura M, Zhou D, Minemura T, Kito S, Okamoto H, Tohyama N, Kurooka M, Kumazaki Y, Ishikawa M, Clark CH, Miles E, Lehmann J, Andratschke N, Kry S, Ishikura S, Mizowaki T, Nishio T. A virtual audit system for intensity-modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study. J Appl Clin Med Phys 2023:e14040. [PMID: 37191875 DOI: 10.1002/acm2.14040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 04/20/2023] [Accepted: 04/24/2023] [Indexed: 05/17/2023] Open
Abstract
PURPOSE The Medical Physics Working Group of the Radiation Therapy Study Group at the Japan Clinical Oncology Group is currently developing a virtual audit system for intensity-modulated radiation therapy dosimetry credentialing. The target dosimeters include films and array detectors, such as ArcCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA) and Delta4 (ScandiDos, Uppsala, Sweden). This pilot study investigated the feasibility of our virtual audit system using previously acquired data. METHODS We analyzed 46 films (32 and 14 in the axial and coronal planes, respectively) from 29 institutions. Global gamma analysis between measured and planned dose distributions used the following settings: 3%/3 mm criteria (the dose denominator was 2 Gy), 30% threshold dose, no scaling of the datasets, and 90% tolerance level. In addition, 21 datasets from nine institutions were obtained for array evaluation. Five institutions used ArcCHECK, while the others used Delta4. Global gamma analysis was performed with 3%/2 mm criteria (the dose denominator was the maximum calculated dose), 10% threshold dose, and 95% tolerance level. The film calibration and gamma analysis were conducted with in-house software developed using Python (version 3.9.2). RESULTS The means ± standard deviations of the gamma passing rates were 99.4 ± 1.5% (range, 92.8%-100%) and 99.2 ± 1.0% (range, 97.0%-100%) in the film and array evaluations, respectively. CONCLUSION This pilot study demonstrated the feasibility of virtual audits. The proposed virtual audit system will contribute to more efficient, cheaper, and more rapid trial credentialing than on-site and postal audits; however, the limitations should be considered when operating our virtual audit system.
Collapse
Affiliation(s)
- Mitsuhiro Nakamura
- Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Dejun Zhou
- Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | | | - Satoshi Kito
- Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Disease Center Komagome Hospital, Tokyo, Japan
| | - Hiroyuki Okamoto
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan
| | - Naoki Tohyama
- Division of Medical Physics, Tokyo Bay Makuhari Clinic for Advanced Imaging, Cancer Screening, and High-Precision Radiotherapy, Chiba, Japan
| | - Masahiko Kurooka
- Department of Radiation Therapy, Tokyo Medical University Hospital, Tokyo, Japan
| | - Yu Kumazaki
- Department of Radiation Oncology, International Medical Center, Saitama Medical University, Saitama, Japan
| | | | - Catharine H Clark
- National Radiotherapy Trials Quality Assurance (RTTQA) Group, Royal Surrey NHS Foundation Trust, London, UK
- Department of Radiotherapy Physics, University College London Hospital, London, UK
- Department of Medical Physics and Bioengineering, University College London, London, UK
- Medical Physics department, National Physical Laboratory (NPL), Teddington, UK
| | - Elizabeth Miles
- National Radiotherapy Trials Quality Assurance (RTTQA) Group, Mount Vernon Cancer Centre, Northwood, UK
| | - Joerg Lehmann
- Trans Tasman Radiation Oncology Group (TROG), Newcastle, Australia
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, Australia
- School of Information and Physical Sciences, University of Newcastle, Newcastle, Australia
- Institute of Medical Physics, University of Sydney, Sydney, Australia
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Stephen Kry
- Imaging and Radiation Oncology Core (IROC), The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Satoshi Ishikura
- Division of Radiation Oncology, Tokyo Bay Makuhari Clinic for Advanced Imaging, Cancer Screening, and High-Precision Radiotherapy, Chiba, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Teiji Nishio
- Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, Osaka, Japan
| |
Collapse
|
4
|
Aghdam SRH, Aghamiri SMR, Siavashpour Z, Malekie S, Dashtipoor MR. Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100. Radiat Phys Chem Oxf Engl 1993 2023; 204:110652. [DOI: https:/doi.org/10.1016/j.radphyschem.2022.110652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/21/2023]
|
5
|
Aghdam SRH, Aghamiri SMR, Siavashpour Z, Malekie S, Dashtipoor MR. Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
6
|
Evaluating the radiation contamination dose around a high dose per pulse intraoperative radiotherapy accelerator: a Monte Carlo study. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920000084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractAim:In this study, the radiation contamination dose (RCD) for different combinations of electron energy/distance, applicator and radius around the light intraoperative accelerator (LIAC), a high dose per pulse dedicated intraoperative electron radiotherapy machine, has been estimated. Being aware about the amount of RCDs is highly recommended for linear medical electron accelerators.Methods and methods:Monte Carlo Nuclear Particles (MCNP) code was used to simulate the LIAC® head and calculate RCDs. Experimental RCDs measurements were also done by Advanced Markus chamber inside a MP3-XS water phantom. Relative differences of simulations and measurements were calculated.Result:RCD reduction by distance from the machine follows the inverse-square law, as expected. The RCD was decreased by increasing angle from applicator walls opposed to the electron beam direction. The maximum differences between the simulation and measurement results were lower than 3%.Conclusions:The RCD is strongly dependent on electron beam energy, applicator size and distance from the accelerator head. Agreement between the MCNP results and ionometric dosimetry confirms the applicability of this simulation code in modelling the intraoperative electron beam and obtaining the dosimetric parameters. The RCD is a parameter that would restrict working with LIAC in an unshielded operative room.
Collapse
|
7
|
Organ at risk dose calculation for left sided breast cancer treatments using intraoperative electron radiotherapy: A Monte Carlo-based feasibility study. Appl Radiat Isot 2020; 156:108977. [DOI: 10.1016/j.apradiso.2019.108977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 10/14/2019] [Accepted: 11/07/2019] [Indexed: 12/24/2022]
|
8
|
Baghani HR, Hosseini Aghdam SR, Robatjazi M, Mahdavi SR. Monte Carlo-based determination of radiation leakage dose around a dedicated IOERT accelerator. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2019; 58:263-276. [PMID: 30972494 DOI: 10.1007/s00411-019-00786-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Accepted: 03/07/2019] [Indexed: 06/09/2023]
Abstract
Evaluating the stray radiation around medical electron accelerators is a mandatory issue. Surveying the radiation leakage dose is important for patients, technicians, and health physicists, due to radiation protection aspects. Consequently, radiation leakage dose around the head of a mobile-dedicated intraoperative radiotherapy accelerator (LIAC), at different electron energies and field sizes have been evaluated in this study. More specifically, the MCNPX Monte Carlo code was used to model the LIAC head, connected applicator, and employed water phantom. Radiation leakage dose around the LIAC head was calculated for different energy and field sizes through tuning the Monte Carlo results to the practically measured doses. These measurements were performed using an Advance Markus ionization chamber inside an automated MP3-XS water phantom. The good agreement between the calculated dose distributions within the water tank and corresponding dose measurements show that the simulation model of the LIAC head is appropriate for radiation leakage assessment. The obtained radiation leakage dose distribution highly depends on the electron energy and applicator diameter. With increasing the electron energy, the leakage dose decreased, while increasing the field size increased the leakage dose. It is concluded that the rate of stray radiation and leakage dose around the LIAC head in both vertical and horizontal planes were acceptable according to the recommended radiation protection criteria. To meet the recommended dose limit (100 µSv/week for controlled areas), the maximum number of patients should be kept to four patients per week inside a standard and unshielded operating room.
Collapse
Affiliation(s)
- Hamid Reza Baghani
- Physics Department, Hakim Sabzevari University, Tohid Shahr St., 617976487, P.O. Box: 397, Sabzevar, Iran.
| | | | - Mostafa Robatjazi
- Department of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - Seyed Rabi Mahdavi
- Medical Physics Department, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
9
|
Baghani HR, Robatjazi M, Mahdavi SR, Nafissi N, Akbari ME. Breast intraoperative electron radiotherapy: Image-based setup verification and in-vivo dosimetry. Phys Med 2019; 60:37-43. [PMID: 31000084 DOI: 10.1016/j.ejmp.2019.03.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 02/25/2019] [Accepted: 03/19/2019] [Indexed: 10/27/2022] Open
Abstract
INTRODUCTION Single fraction nature of intraoperative radiotherapy highly demands a quality assurance procedure to qualify both beam setup and treatment delivery. The aim of this study is to evaluate the treatment setup during breast intraoperative electron radiotherapy (IOERT) and in-vivo dose delivery verification. MATERIALS AND METHODS Twenty-five breast cancer patients were enrolled and setup verification for each case was performed using C-arm imaging. The received dose by surface and distal end of target was measured by EBT2 film. The significance level of difference between obtained dosimetry results and predicted ones was evaluated by the T statistical test. RESULTS Acquired C-arm images in two different oblique views revealed any misalignment between the applicator and shielding disk. The mean difference between the measured surface dose and expected one was 1.8% ± 1.2 (p = 0.983) while a great disagreement, 11.1% ± 1.5 (p < 0.001), was observed between the measured distal end dose and expected one. This discrepancy is mainly correlated to the backscattering effect from the shielding disk. Target depth nonuniformities can also contribute to this remarkable difference. CONCLUSION Employing the intraoperative imaging for IOERT setup verification can considerably improve the treatment quality. Therefore, it is suggested to implement this imaging procedure as a part of treatment quality assurance. Favorable agreement between the predicted and measured surface doses demonstrates the applicability of EBT2 film for dose delivery verification. The results of in-vivo dosimetry showed that the electron backscattering from employed shielding disk can affect the received dose by the distal end of tumor bed.
Collapse
Affiliation(s)
- Hamid Reza Baghani
- Physics Department, Hakim Sabzevari University, Shohada-e Hastei Blvd, P.O. 9617976487, Sabzevar, Iran.
| | - Mostafa Robatjazi
- Department of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Shohada-e Hastei Blvd, Sabzevar University of Medical Sciences Campus, P.O. 9617913112, Sabzevar, Iran; Vasei Radiotherapy & Oncology Center, Vasei Hospital, P.O. 9617913113, Sabzevar, Iran.
| | - Seied Rabi Mahdavi
- Department of Medical Physics, Iran University of Medical Sciences. Hemmat Exp. Way, Faculty of Medicine, P.O. 14496141525, Tehran, Iran
| | - Nahid Nafissi
- Department of Breast Surgery, Iran University of Medical Sciences. Hemmat Exp. Way, Faculty of Medicine, P.O. 14496141525, Tehran, Iran
| | - Mohammad Esmail Akbari
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Shohadaye Tajrrish Hospital, Tajrish Sq., P.O. 19996 14414, Tehran, Iran
| |
Collapse
|
10
|
|
11
|
Baghani HR, Robatjazi M, Mahdavi SR, Hosseini Aghdam SR. Evaluating the performance characteristics of some ion chamber dosimeters in high dose per pulse intraoperative electron beam radiation therapy. Phys Med 2019; 58:81-89. [DOI: 10.1016/j.ejmp.2019.01.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Revised: 01/29/2019] [Accepted: 01/30/2019] [Indexed: 10/27/2022] Open
|
12
|
Evaluation of dosimetric properties of shielding disk used in intraoperative electron radiotherapy: A Monte Carlo study. Appl Radiat Isot 2018; 139:107-113. [DOI: 10.1016/j.apradiso.2018.04.037] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Revised: 02/26/2018] [Accepted: 04/30/2018] [Indexed: 11/18/2022]
|
13
|
Breast intraoperative radiotherapy: a review of available modalities, dedicated machines and treatment procedure. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s146039691800033x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
AbstractBackgroundBreast intraoperative radiotherapy (IORT) is a partial irradiation technique that delivers a single fraction of radiation dose to the tumour bed during surgery. The use of this technique is increasing (especially in the Middle East), and therefore, it is essential to have a comprehensive approach to this treatment modality. The aim of this study is to conduct a literature review on available IORT modalities during breast irradiation as well as dedicated IORT machines and associated treatment procedures. The main IORT trials and corresponding clinical outcomes are also studied.Materials and MethodsA computerised search was performed through MEDLINE, PubMed, PubMed Central, ISI web of knowledge and reference list of related articles.ResultsIORT is now feasible through using two main modalities, including low-kilovolt IORT and intraoperative electron radiotherapy (IOERT). The dedicated machines employed and treatment procedure for mentioned modalities are quite different. The outcomes of implemented clinical trials showed that IORT is not inferior to external beam radiotherapy (EBRT) in specifically selected and well-informed patients and can be considered as an alternative to EBRT.ConclusionAlthough the clinical outcomes of introduced IORT methods are comparable, but based on the review results, it could be said that IOERT is the most effective technical method, in view of the treatment time and dose uniformity concepts. The popularity of IORT is mainly due to the distinguished obtained results during breast cancer treatment. Despite the presence of some technical challenges, it is expected that the IORT technique will become more widespread in the immediate future.
Collapse
|
14
|
Robatjazi M, Tanha K, Mahdavi SR, Baghani HR, Mirzaei HR, Mousavi M, Nafissi N, Akbari E. Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator. J Biomed Phys Eng 2018; 8:43-52. [PMID: 29732339 PMCID: PMC5928310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 07/08/2016] [Indexed: 12/04/2022]
Abstract
Background One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. Materials and Methods Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at the bottom of the applicators. These phase-space files were used as an input source in DOSXYZnrc and BEAMDP codes for dose calculation and analysis of the characteristic of the electron beams in all applicators and energies. Results The results of Monte Carlo calculations are in very close agreement with the measurements. There is a decrease in the peak of the initial spectrum when electrons come from the end of accelerator wave guide to the end of applicator. By decreasing the applicator diameter, the mean energy of electron beam decreased. Using applicators and increasing their size, X-ray contamination will increase. The percentage of X-ray contamination increases by applicator diameter. This is related to the increase of the mean energy of electron beams. Conclusion Application of PMMA collimator leads to, although well below accepted level, the production of bremsstrahlung. The results of this study showed that special design of LIAC head accompanying by PMMA collimator system cause to produce an electron beam with an individual dosimetric characteristic making it a useful tool for intraoperative radiotherapy purposes.
Collapse
Affiliation(s)
- M Robatjazi
- Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - K Tanha
- Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran
| | - S R Mahdavi
- Medical Physics Department, Iran University of Medical Sciences, Tehran, Iran
| | - H R Baghani
- Physics Department, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran
| | - H R Mirzaei
- Radiation Therapy Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - M Mousavi
- Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - N Nafissi
- Surgery Department, Iran University of Medical Sciences, Tehran, Iran
| | - E Akbari
- Oncological Surgery Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
15
|
In vivo dosimetry with MOSFETs and GAFCHROMIC films during electron IORT for Accelerated Partial Breast Irradiation. Phys Med 2017; 44:26-33. [DOI: 10.1016/j.ejmp.2017.11.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Revised: 10/19/2017] [Accepted: 11/04/2017] [Indexed: 11/22/2022] Open
|
16
|
Hosseini Daghigh SM, Baghani HR, Aghamiri SMR, Mahdavi SR. Evaluating the performance of TG-43 protocol in esophageal HDR brachytherapy viewpoint to trachea inhomogeneity. Rep Pract Oncol Radiother 2017; 22:284-289. [DOI: 10.1016/j.rpor.2017.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Revised: 02/24/2017] [Accepted: 04/18/2017] [Indexed: 11/30/2022] Open
|
17
|
Heidarloo N, Baghani HR, Aghamiri SMR, Mahdavi SR, Akbari ME. Commissioning of beam shaper applicator for conformal intraoperative electron radiotherapy. Appl Radiat Isot 2017; 123:69-81. [DOI: 10.1016/j.apradiso.2017.02.039] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Revised: 02/04/2017] [Accepted: 02/23/2017] [Indexed: 11/27/2022]
|
18
|
Monte Carlo study on effective source to surface distance for electron beams from a mobile dedicated IORT accelerator. JOURNAL OF RADIOTHERAPY IN PRACTICE 2016. [DOI: 10.1017/s1460396916000455] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurposeThe effective source to surface distance (SSDeff) for different combinations of energy/applicator size of the electron beam produced by the light intraoperative accelerator, a mobile dedicated intraoperative radiotherapy accelerator, has been calculated in this study.MethodsBoth ionometric dosimetry and Monte Carlo (MC) simulation were followed to obtain the SSDeff for different combinations of electron energy/applicator size. Simulations were performed using Monte Carlo Nuclear Particles (MCNP) MC code. Measurements were performed by Advance Markus chamber and inside a polymethyl methacrylate slab phantom. Inverse square law method was employed to determine the SSDeff from acquired dosimetry data.ResultWith increasing the applicator diameter at a given energy, SSDeff is also increased. The same result is obtained with increasing the electron beam energy for a given applicator size. The results of MC-based SSDeff for 10 cm diameter reference applicator at different energies were in a good accordance with those obtained by ionometric dosimetry. The maximum and mean differences between the results were 1·1 and 0·6%, respectively.ConclusionsThe results of this study showed that SSDeff of intraoperative electron beam is highly dependent on the applicator size and is a mild function of electron beam energy. These facts are in accordance with those reported for conventional electron beam. The good agreement between the results of MC simulation and ionometric dosimetry confirms the application of MCNP code in modelling of intraoperative electron beam and obtaining the intended parameters.
Collapse
|
19
|
In vivo dosimetry using radiochromic films (EBT-2) during intraoperative radiotherapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2016. [DOI: 10.1017/s1460396916000273] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
AbstractBackgroundIntraoperative radiotherapy is a method of choice to deliver a critical radiation dose to the tumour bed immediately after surgical excision.AimThe purpose of this work is to check the dose delivered to the patients during intraoperative electron beam radiation therapy (IOERT) in the conservative treatment of breast cancer, by means of reference dose measurement using radiochromic (EBT-2) films.Material and methodsNinety patients with early-stage breast cancer underwent exclusive IOERT to the tumour bed using a LIAC linear accelerator. Absolute dose measurements were done with film pieces. After irradiation, the pixel values of the films were obtained via MATLAB and ImageJ softwares. Calibration curve was also used for calculating net optical density. Expected dose was compared to the patient delivered dose.ResultsThe mean deviation of the delivered dose from the expected one was 2·56% that is well in the accepted criteria. Only in one case, there was a larger deviation due to barometer miscalibration.FindingsEBT-2 film response is independent from dose-per-pulse and as it was shown in this study it can be robustly used during breast IOERT for dosimetric and also positioning verifications.
Collapse
|
20
|
Costa F, Sarmento S, Gomes D, Magalhães H, Arrais R, Moreira G, Cruz MF, Silva JP, Santos L, Sousa O. In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT). Br J Radiol 2016; 89:20160193. [PMID: 27188847 DOI: 10.1259/bjr.20160193] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To characterize in vivo dose distributions during pelvic intraoperative electron radiation therapy (IOERT) for rectal cancer and to assess the alterations introduced by irregular irradiation surfaces in the presence of bevelled applicators. METHODS In vivo measurements were performed with Gafchromic films during 32 IOERT procedures. 1 film per procedure was used for the first 20 procedures. The methodology was then optimized for the remaining 12 procedures by using a set of 3 films. Both the average dose and two-dimensional dose distributions for each film were determined. Phantom measurements were performed for comparison. RESULTS For flat and concave surfaces, the doses measured in vivo agree with expected values. For concave surfaces with step-like irregularities, measured doses tend to be higher than expected doses. Results obtained with three films per procedure show a large variability along the irradiated surface, with important differences from expected profiles. These results are consistent with the presence of surface hotspots, such as those observed in phantoms in the presence of step-like irregularities, as well as fluid build-up. CONCLUSION Clinical dose distributions in the IOERT of rectal cancer are often different from the references used for prescription. Further studies are necessary to assess the impact of these differences on treatment outcomes. In vivo measurements are important, but need to be accompanied by accurate imaging of positioning and irradiated surfaces. ADVANCES IN KNOWLEDGE These results confirm that surface irregularities occur frequently in rectal cancer IOERT and have a measurable effect on the dose distribution.
Collapse
Affiliation(s)
- Filipa Costa
- 1 Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Sandra Sarmento
- 1 Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.,2 Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Dora Gomes
- 3 Radiation Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Helena Magalhães
- 3 Radiation Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Rosário Arrais
- 3 Radiation Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Graciete Moreira
- 4 UCA, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Maria Fátima Cruz
- 4 UCA, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - José Pedro Silva
- 5 Surgical Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Lúcio Santos
- 5 Surgical Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.,6 Experimental Pathology and Therapeutics Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| | - Olga Sousa
- 3 Radiation Oncology Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
| |
Collapse
|
21
|
López-Tarjuelo J, Morillo-Macías V, Bouché-Babiloni A, Boldó-Roda E, Lozoya-Albacar R, Ferrer-Albiach C. Implementation of an intraoperative electron radiotherapy in vivo dosimetry program. Radiat Oncol 2016; 11:41. [PMID: 26980076 PMCID: PMC4793509 DOI: 10.1186/s13014-016-0621-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Accepted: 03/11/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation. In vivo dosimetry has been recommended for IOERT and has been identified as a risk-reduction intervention in the context of an IOERT risk analysis. Despite reports of fruitful experiences, information about in vivo dosimetry in intraoperative radiotherapy is somewhat scarce. Therefore, the aim of this paper is to report our experience in developing a program of in vivo dosimetry for IOERT, from both multidisciplinary and practical approaches, in a consistent patient series. We also report several current weaknesses. METHODS Reinforced TN-502RDM-H mobile metal oxide semiconductor field effect transistors (MOSFETs) and Gafchromic MD-55-2 films were used as a redundant in vivo treatment verification system with an Elekta Precise fixed linear accelerator for calibrations and treatments. In vivo dosimetry was performed in 45 patients in cases involving primary tumors or relapses. The most frequent primary tumors were breast (37 %) and colorectal (29 %), and local recurrences among relapses was 83 %. We made 50 attempts to measure with MOSFETs and 48 attempts to measure with films in the treatment zones. The surgical team placed both detectors with supervision from the radiation oncologist and following their instructions. RESULTS The program was considered an overall success by the different professionals involved. The absorbed doses measured with MOSFETs and films were 93.8 ± 6.7 % and 97.9 ± 9.0 % (mean ± SD) respectively using a scale in which 90 % is the prescribed dose and 100 % is the maximum absorbed dose delivered by the beam. However, in 10 % of cases we experienced dosimetric problems due to detector misalignment, a situation which might be avoided with additional checks. The useful MOSFET lifetime length and the film sterilization procedure should also be controlled. CONCLUSIONS It is feasible to establish an in vivo dosimetry program for a wide set of locations treated with IOERT using a multidisciplinary approach according to the skills of the professionals present and the detectors used; oncological surgeons' commitment is key to success in this context. Films are more unstable and show higher uncertainty than MOSFETs but are cheaper and are useful and convenient if real-time treatment monitoring is not necessary.
Collapse
Affiliation(s)
- Juan López-Tarjuelo
- Servicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, Avda. Dr. Clará, nº 19, Castellón de la Plana, 12004, Castellón, Spain.
| | - Virginia Morillo-Macías
- Servicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Castellón de la Plana, Spain
- Unitat predepartamental de Medicina, Facultat de Ciències de la Salut, Universitat Jaume I, Avda. Vicent Sos Baynat, s/n, Castellón de la Plana, 12071, Castellón, Spain
| | - Ana Bouché-Babiloni
- Servicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Castellón de la Plana, Spain
| | - Enrique Boldó-Roda
- Unidad de Cirugía Oncológica, Servicio de Cirugía, Consorcio Hospitalario Provincial de Castellón, Castellón de la Plana, Spain
| | - Rafael Lozoya-Albacar
- Unidad de Cirugía Oncológica, Servicio de Cirugía, Consorcio Hospitalario Provincial de Castellón, Castellón de la Plana, Spain
| | - Carlos Ferrer-Albiach
- Servicio de Oncología Radioterápica, Consorcio Hospitalario Provincial de Castellón, Castellón de la Plana, Spain
- Departamento de Medicina y Cirugía, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, C/ Grecia 31, Castellón de la Plana, 12006, Castellón, Spain
| |
Collapse
|
22
|
Chiavassa S, Buge F, Hervé C, Delpon G, Rigaud J, Lisbona A, Supiot S. Monte Carlo evaluation of the effect of inhomogeneities on dose calculation for low energy photons intra-operative radiation therapy in pelvic area. Phys Med 2015; 31:956-962. [DOI: 10.1016/j.ejmp.2015.07.144] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 06/10/2015] [Accepted: 07/03/2015] [Indexed: 10/25/2022] Open
|
23
|
Liuzzi R, Savino F, D’Avino V, Pugliese M, Cella L. Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance. PLoS One 2015; 10:e0139287. [PMID: 26427065 PMCID: PMC4591127 DOI: 10.1371/journal.pone.0139287] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Accepted: 09/09/2015] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters. METHODS LiF:Mg,Ti dosimeters (TLD-100) were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV) and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy. RESULTS The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05). CONCLUSIONS This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.
Collapse
Affiliation(s)
- Raffaele Liuzzi
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy
| | - Federica Savino
- Department of Physics, Federico II University, Naples, Italy
| | - Vittoria D’Avino
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy
| | | | - Laura Cella
- Institute of Biostructure and Bioimaging, National Research Council (CNR), Naples, Italy
| |
Collapse
|