Scott H, Alvarez PE, Howell RM, Riegel A, Sun R, Liu K, Kry SF. Chromatic bleaching and fractionation effects on optically stimulated luminescent dosimeter reuse. Med Phys 2024. [PMID: 38852196 DOI: 10.1002/mp.17231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 04/14/2024] [Accepted: 05/02/2024] [Indexed: 06/11/2024] Open
Abstract
BACKGROUND Optically stimulated luminescent dosimeters (OSLDs) can be bleached and reused, but questions remain about the effects of repeated bleaching and fractionation schedules on OSLD performance. PURPOSE The aim of this study was to investigate how light sources with different wavelengths and different fractionation schemes affect the performance of reused OSLDs. METHODS OSLDs (N = 240) were irradiated on a cobalt-60 beam in different step sizes until they reached an accumulated dose of 50 Gy. Between irradiations they were bleached using light sources of different wavelengths: the Imaging and Radiation Oncology Core (IROC) bleaching system (our control); monochromatic red, green, yellow, and blue lights; and a polychromatic white light. Sensitivity and linearity-based correction factors were determined as a function of dose step-size. The rate of signal removal from different light sources was characterized by sampling these OSLDs at various time points during their bleaching process. Relative doses were calculated according to the American Association of Physicists in Medicine Task Group-191. Signal repopulation was investigated by irradiating OSLDs (N = 300) to various delivered doses of 2, 10, 20, 30, 40, and 50 Gy in a single fraction, bleached with one of the colors, and read over time. Fractionation effects were evaluated by irradiating OSLDs up to 30 Gy in different size steps. After reading, the OSLDs were bleached following IROC protocol. OSLDs (N = 40) received irradiations in 5, 10, 15, 30 Gy fractions until they had an accumulated dose of 30 Gy; The sensitivity response of these OSLDs was compared with reference OSLDs that had no accumulated dose. RESULTS Light sources with polychromatic spectrums (IROC and white) bleached OSLDs faster than did sources with monochromatic spectra. Polychromatic light sources (white light and IROC system) provided the greatest dose stability for OSLDs that had larger amounts of accumulated dose. Signal repopulation was related to the choice of bleaching light source, timing of bleaching, and amount of accumulated dose. Changes to relative dosimetry were more pronounced in OSLDs that received larger fractions. At 5-Gy fractions and above, all OSLDs had heightened sensitivity, with OSLDs exposed to 30-Gy fractions being 6.4% more sensitive than reference dosimeters. CONCLUSIONS The choice of bleaching light plays a role in how fast an OSLD is bleached and how much accumulated dose an OSLD can be exposed to while maintaining stable signal sensitivity. We have expanded upon investigations into signal repopulation to show that bleaching light plays a role in the migration of deep traps to dosimetric traps after bleaching. Our research concludes that the bleaching light source and fractionation need to be considered when reusing OSLD.
Collapse
Affiliation(s)
- Hayden Scott
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| | - Paola E Alvarez
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rebecca M Howell
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| | - Adam Riegel
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York City, New York, USA
| | - Ryan Sun
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Kevin Liu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| | - Stephen F Kry
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| |
Collapse
|
2
|
Park SY, Park JM, Kim JI, Choi CH, Chun M, Chang JH, Kim JH. Quantitative radiomics approach to assess acute radiation dermatitis in breast cancer patients. PLoS One 2023; 18:e0293071. [PMID: 37883380 PMCID: PMC10602246 DOI: 10.1371/journal.pone.0293071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 10/04/2023] [Indexed: 10/28/2023] Open
Abstract
PURPOSE We applied a radiomics approach to skin surface images to objectively assess acute radiation dermatitis in patients undergoing radiotherapy for breast cancer. METHODS A prospective cohort study of 20 patients was conducted. Skin surface images in normal, polarized, and ultraviolet (UV) modes were acquired using a skin analysis device before starting radiotherapy ('Before RT'), approximately 7 days after the first treatment ('RT D7'), on 'RT D14', and approximately 10 days after the radiotherapy ended ('After RT D10'). Eighteen types of radiomic feature ratios were calculated based on the values acquired 'Before RT'. We measured skin doses in ipsilateral breasts using optically stimulated luminescent dosimeters on the first day of radiotherapy. Clinical evaluation of acute radiation dermatitis was performed using the Radiation Therapy Oncology Group scoring criteria on 'RT D14' and 'After RT D10'. Several statistical analysis methods were used in this study to test the performance of radiomic features as indicators of radiodermatitis evaluation. RESULTS As the skin was damaged by radiation, the energy for normal mode and sum variance for polarized and UV modes decreased significantly for ipsilateral breasts, whereas contralateral breasts exhibited a smaller decrease with statistical significance. The radiomic feature ratios at 'RT D7' had strong correlations to skin doses and those at 'RT D14' and 'after RT D10' with statistical significance. CONCLUSIONS The energy for normal mode and sum variance for polarized and UV modes demonstrated the potential to evaluate and predict acute radiation, which assists in its appropriate management.
Collapse
Affiliation(s)
- So-Yeon Park
- Department of Radiation Oncology, Veterans Health Service Medical Center, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jong Min Park
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
- Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Jung-in Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Chang Heon Choi
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Minsoo Chun
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Ji Hyun Chang
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jin Ho Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| |
Collapse
|
3
|
Shin DS, Kim TH, Rah JE, Lee SB, Lim YK, Jeong J, Kim H, Shin D, Son J. Flexible real-time skin dosimeter based on a thin-film copper indium gallium selenide solar cell for electron radiation therapy. Med Phys 2022; 50:2402-2416. [PMID: 36583513 DOI: 10.1002/mp.16191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 11/20/2022] [Accepted: 12/13/2022] [Indexed: 12/31/2022] Open
Abstract
PURPOSE Various dosimeters have been proposed for skin dosimetry in electron radiotherapy. However, one main drawback of these skin dosimeters is their lack of flexibility, which could make accurate dose measurements challenging due to air gaps between a curved patient surface and dosimeter. Therefore, the purpose of this study is to suggest a novel flexible skin dosimeter based on a thin-film copper indium gallium selenide (CIGS) solar cell, and to evaluate its dosimetric characteristics. METHODS The CIGS solar cell dosimeter consisted of (a) a customized thin-film CIGS solar cell and (b) a data acquisition (DAQ) system. The CIGS solar cell with a thickness of 0.33 mm was customized to a size of 10 × 10 mm2 . This customized solar cell plays a role in converting therapeutic electron radiation into electrical signals. The DAQ system was composed of a voltage amplifier with a gain of 1000, a voltage input module, a DAQ chassis, and an in-house software. This system converted the electrical analog signals (from solar cell) to digital signals with a sampling rate of ≤50 kHz and then quantified/visualized the digital signals in real time. We quantified the linearity/ sampling rate effect/dose rate dependence/energy dependence/field size output factor/reproducibility/curvature/bending recoverability/angular dependence of the CIGS solar cell dosimeter in therapeutic electron beams. To evaluate clinical feasibility, we measured the skin point doses by attaching the CIGS solar cell to an anthropomorphic phantom surface (for forehead, mouth, and thorax). The CIGS-measured doses were compared with calculated doses (by treatment planning system) and measured doses (by optically stimulated luminescent dosimeter). RESULTS The normalized signals of the solar cell dosimeter increased linearly as the delivered dose increased. The gradient of the linearly fitted line was 1.00 with an R-square of 0.9999. The sampling rates (2, 10, and 50 kHz) of the solar cell dosimeter showed good performance even at low doses (<50 cGy). The solar cell dosimeter exhibited dose rate independence within 1% and energy independence within 3% error margins. The signals of the solar cell dosimeter were similar (<1%) when penetrating the same side of the CIGS cell regardless of the rotation angle of the solar cell. The field size output factor measured by the solar cell dosimeter was comparable to that measured by the ion chamber. The solar cell signals were similar between the baseline (week 1) and the last time point (week 4). Our detector showed curvature independence within 1.8% (curvatures of <0.10 mm- ) and bending recovery (curvature of 0.10 mm-1 ). The differences between measured doses (CIGS solar cell dosimeter vs. optically stimulated luminescent dosimeter) were 7.1%, 9.6%, and 1.0% for forehead, mouth, and thorax, respectively. CONCLUSION We present the construction of a flexible skin dosimeter based on a CIGS solar cell. Our findings demonstrate that the CIGS solar cell has a potential to be a novel flexible skin dosimeter for electron radiotherapy. Moreover, this dosimeter is manufactured with low cost and can be easily customized to various size/shape, which represents advantages over other dosimeters.
Collapse
Affiliation(s)
- Dong-Seok Shin
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Tae-Ho Kim
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Jeong-Eun Rah
- Department of Radiation Oncology, Myongji Hospital, Goyang, Republic of Korea
| | - Se Byeong Lee
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Young Kyung Lim
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Jonghwi Jeong
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Haksoo Kim
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Dongho Shin
- Proton Therapy Center, National Cancer Center, Goyang, Republic of Korea
| | - Jaeman Son
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
| |
Collapse
|
4
|
Goto S, Hayashi H, Yamaguchi H, Sekiguchi H, Akino R, Shimizu M. Signal-stabilized Al2O3:C-OSL dosimeter “checking chip” for correcting OSL reader sensitivity variation. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
5
|
Shin DS, Kim TH, Rah JE, Kim D, Yang HJ, Lee SB, Lim YK, Jeong J, Kim H, Shin D, Son J. Assessment of a Therapeutic X-ray Radiation Dose Measurement System Based on a Flexible Copper Indium Gallium Selenide Solar Cell. SENSORS (BASEL, SWITZERLAND) 2022; 22:5819. [PMID: 35957376 PMCID: PMC9370937 DOI: 10.3390/s22155819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 08/02/2022] [Accepted: 08/02/2022] [Indexed: 06/15/2023]
Abstract
Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.
Collapse
Affiliation(s)
- Dong-Seok Shin
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Tae-Ho Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jeong-Eun Rah
- Department of Radiation Oncology, Myongji Hospital, Goyang 10475, Korea
| | - Dohyeon Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Hye Jeong Yang
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Se Byeong Lee
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Young Kyung Lim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jonghwi Jeong
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Haksoo Kim
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Dongho Shin
- Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
| | - Jaeman Son
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Korea
| |
Collapse
|
6
|
Han SC. Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity. PLoS One 2022; 17:e0266110. [PMID: 35349607 PMCID: PMC8963533 DOI: 10.1371/journal.pone.0266110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/14/2022] [Indexed: 11/18/2022] Open
Abstract
The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x − 3125.3 (r2 = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x2 + 70444.6x − 6142.3 (r2 = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = −15.5x3 + 527.3x2 + 75059.6x − 16260.3 (r2 = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 ± 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 ± 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process.
Collapse
Affiliation(s)
- Su Chul Han
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Korea
- * E-mail:
| |
Collapse
|
7
|
Jung S, Kim JI, Park JM, Wu HG, Choi CH. Gold coated contact lens-type ocular in vivo dosimeter (CLOD) for monitoring of low dose in computed tomography: A Monte Carlo study. Phys Med 2021; 92:1-7. [PMID: 34781119 DOI: 10.1016/j.ejmp.2021.10.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 10/06/2021] [Accepted: 10/28/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE This study reports a sensitivity enhancement of gold-coated contact lens-type ocular in vivo dosimeters (CLODs) for low-dose measurements in computed tomography (CT). METHODS Monte Carlo (MC) simulations were conducted to evaluate the dose enhancement from the gold (Au) layers on the CLODs. The human eye and CLODs were modeled, and the X-ray tube voltages were defined as 80, 120, and 140 kVp. The thickness of the Au layer attached to a CLOD ranged from 100 nm to 10 μm. The thickness of the active layer ranged from 20 to 140 μm. The dose ratio between the active layer of the Au-coated CLOD and a CLOD without a layer, i.e., the dose enhancement factor (DEF), was calculated. RESULTS The DEFs of the first 20-μm thick active layer of the 5-μm thick Au-coated CLOD were 18.4, 19.7, 20.2 at 80, 120, and 140 kVp, respectively. The DEFs decreased as the thickness of the active layer increased. The DEFs of 100-nm to 5-μm thick Au layers increased from 1.7 to 5.4 for 120-kVp X-ray tube voltage when the thickness of the active layer was 140 μm. CONCLUSIONS The MC results presented a higher sensitivity of Au-coated CLODs (∼20-times higher than that of CLODs without a gold layer). Au-coated CLODs can be applied to an evaluation of very low doses (a few cGy) delivered to patients during CT imaging.
Collapse
Affiliation(s)
- Seongmoon Jung
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea; Department of Radiation Oncology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Robotics Research Laboratory for Extreme Environments, Advanced Institute of Convergence Technology, Suwon 16229, Republic of Korea
| | - Hong-Gyun Wu
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea; Cancer Research Institute, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Department of Radiation Oncology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea.
| |
Collapse
|
8
|
Liu K. Preliminary Investigation into the regeneration of luminescent signal in nanoDot OSLDs. J Appl Clin Med Phys 2020; 21:256-262. [PMID: 33001568 PMCID: PMC7700939 DOI: 10.1002/acm2.13035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 08/07/2020] [Accepted: 08/12/2020] [Indexed: 01/12/2023] Open
Abstract
Purpose Methods Results Conclusion
Collapse
|
9
|
Jursinic PA. Optically stimulated luminescent dosimeters stable response to dose after repeated bleaching. Med Phys 2020; 47:3191-3203. [DOI: 10.1002/mp.14182] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 04/03/2020] [Accepted: 04/05/2020] [Indexed: 11/09/2022] Open
Affiliation(s)
- Paul A. Jursinic
- West Michigan Cancer Center 200 North Park Street Kalamazoo MI 49007 USA
| |
Collapse
|
10
|
Kim JI, Cho JD, Son J, Choi CH, Wu HG, Park JM. Contact lens-type ocular in vivo dosimeter for radiotherapy. Med Phys 2019; 47:722-735. [PMID: 31743441 DOI: 10.1002/mp.13932] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 10/26/2019] [Accepted: 11/13/2019] [Indexed: 12/31/2022] Open
Abstract
PURPOSE This study aimed to (a) develop a contact lens-type ocular in vivo dosimeter (CLOD) that can be worn directly on the eye and (b) assess its dosimetric characteristics and biological stability for radiation therapy. METHODS The molder of a soft contact lens was directly used to create the dosimeter, which included a radiation-sensitive component - an active layer similar to a radiochromic film - to measure the delivered dose. A flatbed scanner with a reflection mode was used to measure the change in optical density due to irradiation. The sensitivity, energy, dose rate, and angular dependence were tested, and the uncertainty in determining the dose was calculated using error propagation analysis. Sequential biological stability tests, specifically, cytotoxicity and ocular irritation tests, were conducted to ensure the safe application of the CLOD to patients. RESULTS The dosimeter demonstrated high sensitivity in the low dose region, and the sensitivity linearly decreased with the dose. The responses obtained for the 10 and 15 MV photon beams were 1.7% and 1.9% higher compared to the 6 MV photon beam. A strong dose rate dependence was not obtained for the CLOD. Angular dependence was observed from 90° to 180° with a difference in response from 1% to 2%. The total uncertainty in error propagation analysis decreased as a function of the dose in the red channel. For a dose range of 0 to 50 cGy, the total uncertainties for 5, 10, and 50 cGy were 14.2%, 8.9%, and 5%, respectively. Quantitative evaluation using the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) method presented no cytotoxicity. Further, no corneal opacity, iris reaction, or conjunctival inflammation was observed. CONCLUSIONS The CLOD is the first dosimeter that can be worn close to the eye. The results of cytotoxicity and irritation tests indicate that it is a stable medical device. The evaluation of dose characteristics in open field conditions shows that the CLOD can be applied to an in vivo dosimeter in radiotherapy.
Collapse
Affiliation(s)
- Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Jin-Dong Cho
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Department of Radiation Oncology, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
| | - Jaeman Son
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Hong-Gyun Wu
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Robotics Research Laboratory for Extreme Environments, Advanced Institute of Convergence Technology, Suwon, 16229, Republic of Korea
| |
Collapse
|
11
|
Giansante L, Santos JC, Umisedo NK, Terini RA, Costa PR. Characterization of OSL dosimeters for use in dose assessment in Computed Tomography procedures. Phys Med 2018; 47:16-22. [DOI: 10.1016/j.ejmp.2018.02.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 02/10/2018] [Accepted: 02/13/2018] [Indexed: 10/18/2022] Open
|