1
|
Tsuzura K, Wagatsuma K, Kamitaka Y, Miwa K, Miyaji N, Kamiya T, Yokotsuka N, Ishii K. Phantom test procedures for a new neuro-oncological amino acid PET tracer: [ 18F]fluciclovine. Ann Nucl Med 2024:10.1007/s12149-024-01973-x. [PMID: 39207631 DOI: 10.1007/s12149-024-01973-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Accepted: 08/21/2024] [Indexed: 09/04/2024]
Abstract
OBJECTIVE Amino acid positron emission tomography (PET) examinations using anti-1-amino-3-[18F]-fluorocyclobutane-1-carboxylic acid ([18F]FACBC) were allowed for routine clinical use in July 2024. However, phantom test procedures for [18F]FACBC reconstruction parameters have not yet been established. The present study aimed to establish new phantom test procedures for [18F]FACBC brain PET imaging to determine optimal reconstruction parameters. METHODS Background (BG) activity as well as hot sphere and target-to-background ratios (TBRs) of [18F]FACBC were estimated based on brain activity and tumor-to-normal tissue ratios (TNR) in a Japanese clinical trial of [18F]FACBC. Phantom experiments proceeded under [18F]FACBC or L-[methyl-11C]-methionine ([11C]MET) conditions. The number of iterations and the Gaussian filter parameters were determined from the reconstruction parameters %contrastmean and coefficients of variation (CVs) in ordered subset expectation maximization (OSEM) and time-of-flight (TOF) with or without point-spread-function (PSF) correction. RESULTS The amounts of activity in the hot spheres and BG were 1.1 and 5.5 kBq/mL, respectively, and the TBR was 5.0 at the start of acquisition. The %contrastmean of all hot spheres was higher with [18F]FACBC than [11C]MET, and %contrastmean converged between 4 and 6 iterations in hot spheres with diameters < 10 mm. We used four iterations for OSEM + TOF and five for OSEM + TOF + PSF correction for [18F]FACBC and [11C]MET images. The CV was higher for [18F]FACBC than [11C]MET. The optimal sizes of Gaussian filters for OSEM + TOF and OSEM + TOF + PSF correction of image reconstruction were 5 mm for [18F]FACBC, and 4 and 3 mm, respectively, for [11C]MET images. CONCLUSIONS We estimated phantom activity and TBR based on brain activity in a Japanese clinical trial and established new phantom test procedures for [18F]FACBC. We recommend that the optimal reconstruction parameters for [18F]FACBC should be set to the same number of iterations as [11C]MET and that the FWHM of Gaussian filter should have a few mm higher than [11C]MET to reduce image noise from brain normal tissue.
Collapse
Affiliation(s)
- Kaede Tsuzura
- Department of Medical Technology, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kei Wagatsuma
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-Cho, Itabashi-ku, Tokyo, 173-0015, Japan.
| | - Yuto Kamitaka
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-Cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Noriaki Miyaji
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Takashi Kamiya
- Department of Medical Technology, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Noriyo Yokotsuka
- Faculty of Medical Technology, Department of Radiological Technology, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan
| | - Kenji Ishii
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-Cho, Itabashi-ku, Tokyo, 173-0015, Japan
| |
Collapse
|
2
|
Fukuda S, Wagatsuma K, Miwa K, Yakushiji Y, Kamitaka Y, Yamao T, Miyaji N, Ishii K. Optimization of penalization function in Bayesian penalized likelihood reconstruction algorithm for [ 18F]flutemetamol amyloid PET images. Phys Eng Sci Med 2024:10.1007/s13246-024-01476-z. [PMID: 39133373 DOI: 10.1007/s13246-024-01476-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Accepted: 08/06/2024] [Indexed: 08/13/2024]
Abstract
Point-spread-function (PSF) correction is not recommended for amyloid PET images due to Gibbs artifacts. Q.Clear™, a Bayesian Penalized Likelihood (BPL) reconstruction method without incorporating PSF correction reduces these artifacts but degrades image contrast by our previous findings. The present study aimed to recover lost contrast by optimizing reconstruction parameters in time-of-flight (TOF) BPL reconstruction of amyloid PET images without PSF correction. We selected candidate conditions based on a phantom study and then determined which were optimal in a clinical study. Phantom images were reconstructed under conditions of 1‒9 iterations, β 300-1000 and γ factors from 2 to 10 in TOF-BPL without PSF correction. We evaluated the %contrast and the coefficients of variation (CV, %). Standardized uptake value ratios (SUVr) and Centiloid scales (CL) were calculated from PET images acquired from 71 participants after an [18F]flutemetamol injection. Both %contrast and CV were independent of iterations, whereas a trade-off was found between γ factors and β. We selected a γ factors of 5 without PSF correction (iterations, 1; β, 500) and of 10 without PSF correction (iterations, 1; β, 800) as candidates for clinical investigation. The SUVr and CL remained stable across various conditions, and CL scales effectively discriminated amyloid PET using measured values. The optimal reconstruction parameters of TOF-BPL for [18F]flutemetamol PET images were γ factor 10, iterations 1 and β 800, without PSF correction.
Collapse
Affiliation(s)
- Shohei Fukuda
- Medical Engineering, Kitasato University Graduate School of Medical Sciences, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Kei Wagatsuma
- Medical Engineering, Kitasato University Graduate School of Medical Sciences, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Yu Yakushiji
- Medical Engineering, Kitasato University Graduate School of Medical Sciences, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Yuto Kamitaka
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Tensho Yamao
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Noriaki Miyaji
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Kenji Ishii
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| |
Collapse
|
3
|
Wagatsuma K, Sakata M, Miwa K, Hamano Y, Kawakami H, Kamitaka Y, Yamao T, Miyaji N, Ishibashi K, Tago T, Toyohara J, Ishii K. Phantom and clinical evaluation of the Bayesian penalised likelihood reconstruction algorithm Q.Clear without PSF correction in amyloid PET images. EJNMMI Phys 2024; 11:37. [PMID: 38647924 PMCID: PMC11035535 DOI: 10.1186/s40658-024-00641-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 04/12/2024] [Indexed: 04/25/2024] Open
Abstract
PURPOSE Bayesian penalised likelihood (BPL) reconstruction, which incorporates point-spread-function (PSF) correction, provides higher signal-to-noise ratios and more accurate quantitation than conventional ordered subset expectation maximization (OSEM) reconstruction. However, applying PSF correction to brain PET imaging is controversial due to Gibbs artefacts that manifest as unpredicted cortical uptake enhancement. The present study aimed to validate whether BPL without PSF would be useful for amyloid PET imaging. METHODS Images were acquired from Hoffman 3D brain and cylindrical phantoms for phantom study and 71 patients administered with [18F]flutemetamol in clinical study using a Discovery MI. All images were reconstructed using OSEM, BPL with PSF correction, and BPL without PSF correction. Count profile, %contrast, recovery coefficients (RCs), and image noise were calculated from the images acquired from the phantoms. Amyloid β deposition in patients was visually assessed by two physicians and quantified based on the standardised uptake value ratio (SUVR). RESULTS The overestimated radioactivity in profile curves was eliminated using BPL without PSF correction. The %contrast and image noise decreased with increasing β values in phantom images. Image quality and RCs were better using BPL with, than without PSF correction or OSEM. An optimal β value of 600 was determined for BPL without PSF correction. Visual evaluation almost agreed perfectly (κ = 0.91-0.97), without depending on reconstruction methods. Composite SUVRs did not significantly differ between reconstruction methods. CONCLUSION Gibbs artefacts disappeared from phantom images using the BPL without PSF correction. Visual and quantitative evaluation of [18F]flutemetamol imaging was independent of the reconstruction method. The BPL without PSF correction could be the standard reconstruction method for amyloid PET imaging, despite being qualitatively inferior to BPL with PSF correction for [18F]flutemetamol amyloid PET imaging.
Collapse
Affiliation(s)
- Kei Wagatsuma
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
| | - Muneyuki Sakata
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Yumi Hamano
- School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan
| | - Hirofumi Kawakami
- GE HealthCare Japan, 4-7-127 Asahigaoka, Hino-shi, Tokyo, 191-8503, Japan
| | - Yuto Kamitaka
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Tensho Yamao
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Noriaki Miyaji
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima, 960-8516, Japan
| | - Kenji Ishibashi
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Tetsuro Tago
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Jun Toyohara
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| | - Kenji Ishii
- Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan
| |
Collapse
|
4
|
Cox CPW, Brabander T, Vegt E, de Lussanet de la Sablonière QG, Graven LH, Verburg FA, Segbers M. Reduction of [ 68Ga]Ga-DOTA-TATE injected activity for digital PET/MR in comparison with analogue PET/CT. EJNMMI Phys 2024; 11:27. [PMID: 38488989 PMCID: PMC11266332 DOI: 10.1186/s40658-024-00629-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 03/06/2024] [Indexed: 03/17/2024] Open
Abstract
BACKGROUND New digital detectors and block-sequential regularized expectation maximization (BSREM) reconstruction algorithm improve positron emission tomography (PET)/magnetic resonance (MR) image quality. The impact on image quality may differ from analogue PET/computed tomography (CT) protocol. The aim of this study is to determine the potential reduction of injected [68Ga]Ga-DOTA-TATE activity for digital PET/MR with BSREM reconstruction while maintaining at least equal image quality compared to the current analogue PET/CT protocol. METHODS NEMA IQ phantom data and 25 patients scheduled for a diagnostic PET/MR were included. According to our current protocol, 1.5 MBq [68Ga]Ga-DOTA-TATE per kilogram (kg) was injected. After 60 min, scans were acquired with 3 (≤ 70 kg) or 4 (> 70 kg) minutes per bedposition. PET/MR scans were reconstructed using BSREM and factors β 150, 300, 450 and 600. List mode data with reduced counts were reconstructed to simulate scans with 17%, 33%, 50% and 67% activity reduction. Image quality was measured quantitatively for PET/CT and PET/MR phantom and patient data. Experienced nuclear medicine physicians performed visual image quality scoring and lesion counting in the PET/MR patient data. RESULTS Phantom analysis resulted in a possible injected activity reduction of 50% with factor β = 600. Quantitative analysis of patient images revealed a possible injected activity reduction of 67% with factor β = 600. Both with equal or improved image quality as compared to PET/CT. However, based on visual scoring a maximum activity reduction of 33% with factor β = 450 was acceptable, which was further limited by lesion detectability analysis to an injected activity reduction of 17% with factor β = 450. CONCLUSION A digital [68Ga]Ga-DOTA-TATE PET/MR together with BSREM using factor β = 450 result in 17% injected activity reduction with quantitative values at least similar to analogue PET/CT, without compromising on PET/MR visual image quality and lesion detectability.
Collapse
Affiliation(s)
- Christina P W Cox
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands.
| | - Tessa Brabander
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Erik Vegt
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Quido G de Lussanet de la Sablonière
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Laura H Graven
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Frederik A Verburg
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Subesinghe M, Ilyas H, Dunn JT, Mir N, Duran A, Mikhaeel NG, Barrington SF. The frequency of change in five-point scale score with a Bayesian penalised likelihood PET reconstruction algorithm on interim FDG PET-CT and its potential implications for therapy decisions in Hodgkin's lymphoma. Clin Radiol 2023; 78:e89-e98. [PMID: 36333130 DOI: 10.1016/j.crad.2022.09.124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 09/21/2022] [Accepted: 09/23/2022] [Indexed: 11/07/2022]
Abstract
AIM To assess the effect of a Bayesian penalised likelihood (BPL) reconstruction algorithm on the five-point scale (5-PS) score, response categorisation, and potential implications for therapy decisions after interim 2-[18F]-fluoro-2-deoxy-d-glucose (FDG) positron-emission tomography (PET)-computed tomography (CT) (iPET-CT) to guide treatment in classical Hodgkin's lymphoma (HL). MATERIALS AND METHODS The present study included new patients with HL undergoing iPET-CT from 2014-2019 after two cycles of doxorubicin (Adriamycin), bleomycin, vincristine, and dacarbazine (ABVD). Two reporters categorised response using the 5-PS and measured maximum standardised uptake values (SUVmax) of the most avid tumour residuum, mediastinal blood pool, and normal liver with ordered subset expected maximisation (OSEM) and BPL reconstructions. RESULTS Eighty-one iPET-CT examinations were reviewed. Compared with OSEM, BPL increased the 5-PS score by a single score in 18/81 (22.2%) patients. The frequency of potential treatment intensification by changing a score of 3-4 was 13.6% (11/81) and represented 25% (11/44) of patients with a score of 3 on OSEM. All 11 patients remained in remission without a change in therapy (mean 63 months) except one who required second-line treatment for refractory disease. Median SUVmax of tumour residuum was significantly higher with BPL compared with OSEM (2.7 versus 2.4, p<<0.0001), whilst liver SUVmax was significantly lower for both reporters (up to 6.6%, p<0.0001). CONCLUSION BPL PET reconstruction increased the 5-PS score on iPET-CT in 22% of HL patients and can potentially result in unnecessary treatment escalation in over half of these patients.
Collapse
Affiliation(s)
- M Subesinghe
- King's College London & Guy's and St Thomas' PET Centre, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
| | - H Ilyas
- Department of Nuclear Medicine, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - J T Dunn
- King's College London & Guy's and St Thomas' PET Centre, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - N Mir
- Department of Haematology, Lewisham and Greenwich NHS Trust, London, UK
| | - A Duran
- Department of Haematology, Lewisham and Greenwich NHS Trust, London, UK
| | - N G Mikhaeel
- Department of Clinical Oncology, Guy's and St Thomas' NHS Foundation Trust, London, UK; School of Cancer & Pharmaceutical Sciences, King's College London, London, UK
| | - S F Barrington
- King's College London & Guy's and St Thomas' PET Centre, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| |
Collapse
|
6
|
Miwa K, Yoshii T, Wagatsuma K, Nezu S, Kamitaka Y, Yamao T, Kobayashi R, Fukuda S, Yakushiji Y, Miyaji N, Ishii K. Impact of γ factor in the penalty function of Bayesian penalized likelihood reconstruction (Q.Clear) to achieve high-resolution PET images. EJNMMI Phys 2023; 10:4. [PMID: 36681994 PMCID: PMC9868206 DOI: 10.1186/s40658-023-00527-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Accepted: 01/16/2023] [Indexed: 01/23/2023] Open
Abstract
BACKGROUND The Bayesian penalized likelihood PET reconstruction (BPL) algorithm, Q.Clear (GE Healthcare), has recently been clinically applied to clinical image reconstruction. The BPL includes a relative difference penalty (RDP) as a penalty function. The β value that controls the behavior of RDP determines the global strength of noise suppression, whereas the γ factor in RDP controls the degree of edge preservation. The present study aimed to assess the effects of various γ factors in RDP on the ability to detect sub-centimeter lesions. METHODS All PET data were acquired for 10 min using a Discovery MI PET/CT system (GE Healthcare). We used a NEMA IEC body phantom containing spheres with inner diameters of 10, 13, 17, 22, 28 and 37 mm and 4.0, 5.0, 6.2, 7.9, 10 and 13 mm. The target-to-background ratio of the phantom was 4:1, and the background activity concentration was 5.3 kBq/mL. We also evaluated cold spheres containing only non-radioactive water with the same background activity concentration. All images were reconstructed using BPL + time of flight (TOF). The ranges of β values and γ factors in BPL were 50-600 and 2-20, respectively. We reconstructed PET images using the Duetto toolbox for MATLAB software. We calculated the % hot contrast recovery coefficient (CRChot) of each hot sphere, the cold CRC (CRCcold) of each cold sphere, the background variability (BV) and residual lung error (LE). We measured the full width at half maximum (FWHM) of the micro hollow hot spheres ≤ 13 mm to assess spatial resolution on the reconstructed PET images. RESULTS The CRChot and CRCcold for different β values and γ factors depended on the size of the small spheres. The CRChot, CRCcold and BV increased along with the γ factor. A 6.2-mm hot sphere was obvious in BPL as lower β values and higher γ factors, whereas γ factors ≥ 10 resulted in images with increased background noise. The FWHM became smaller when the γ factor increased. CONCLUSION High and low γ factors, respectively, preserved the edges of reconstructed PET images and promoted image smoothing. The BPL with a γ factor above the default value in Q.Clear (γ factor = 2) generated high-resolution PET images, although image noise slightly diverged. Optimizing the β value and the γ factor in BPL enabled the detection of lesions ≤ 6.2 mm.
Collapse
Affiliation(s)
- Kenta Miwa
- grid.411582.b0000 0001 1017 9540Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima 960-8516 Japan ,grid.420122.70000 0000 9337 2516Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015 Japan ,grid.471467.70000 0004 0449 2946Department of Radiology, Fukushima Medical University Hospital, 1 Hikarigaoka, Fukushima, Fukushima 960-1295 Japan
| | - Tokiya Yoshii
- grid.471467.70000 0004 0449 2946Department of Radiology, Fukushima Medical University Hospital, 1 Hikarigaoka, Fukushima, Fukushima 960-1295 Japan
| | - Kei Wagatsuma
- grid.420122.70000 0000 9337 2516Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015 Japan ,grid.410786.c0000 0000 9206 2938School of Allied Health Sciences, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa 252-0373 Japan
| | - Shogo Nezu
- grid.452478.80000 0004 0621 7227Department of Radiology, Ehime University Hospital, 454 Shitsukawa, Touon-shi, Ehime 791-0204 Japan
| | - Yuto Kamitaka
- grid.420122.70000 0000 9337 2516Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015 Japan
| | - Tensho Yamao
- grid.411582.b0000 0001 1017 9540Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, Fukushima 960-8516 Japan
| | - Rinya Kobayashi
- grid.412767.1Department of Radiology, Tokai University Hospital, 143 Shimokasuya, Isehara-shi, Kanagawa 259-1193 Japan
| | - Shohei Fukuda
- grid.411731.10000 0004 0531 3030Department of Radiological Sciences, School of Health Sciences, International University of Health and Welfare, 2600-1 Kitakanemaru, Ohtawara, Tochigi 324-8501 Japan
| | - Yu Yakushiji
- grid.411731.10000 0004 0531 3030Department of Radiological Sciences, School of Health Sciences, International University of Health and Welfare, 2600-1 Kitakanemaru, Ohtawara, Tochigi 324-8501 Japan
| | - Noriaki Miyaji
- grid.410807.a0000 0001 0037 4131Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550 Japan
| | - Kenji Ishii
- grid.420122.70000 0000 9337 2516Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo, 173-0015 Japan
| |
Collapse
|
7
|
Miwa K, Miyaji N, Yamao T, Kamitaka Y, Wagatsuma K, Murata T. [[PET] 5. Recent Advances in PET Image Reconstruction Using a Bayesian Penalized Likelihood Algorithm]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:477-487. [PMID: 37211404 DOI: 10.6009/jjrt.2023-2200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Affiliation(s)
- Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Noriaki Miyaji
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | - Tensho Yamao
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | - Yuto Kamitaka
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Kei Wagatsuma
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
- School of Allied Health Sciences, Kitasato University
| | | |
Collapse
|
8
|
Kojima I, Takanami K, Ogawa T, Ishikawa K, Morishita Y, Ishii R, Ohkoshi A, Nakanome A, Odagiri H, Iikubo M. High diagnostic accuracy for lymph node metastasis of oral squamous cell carcinoma using PET/CT with a silicon photomultiplier. Oral Radiol 2022; 38:540-549. [PMID: 35061164 DOI: 10.1007/s11282-022-00588-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 01/03/2022] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The higher sensitivity of the new-generation positron emission tomography/computed tomography (PET/CT) with silicon photomultiplier (SiPM) may increase false-positive rates in detecting metastatic lymph nodes (LNs). This study aimed to clarify the usefulness of the SiPM PET scanner in diagnosing LN metastasis of oral squamous cell carcinoma (SCC). METHODS We retrospectively reviewed consecutive F-18 fluorodeoxyglucose PET/CT images of 39 SCC patients using SiPM PET and 31 SCC patients using non-SiPM PET. We measured the maximum standardized uptake value (SUVmax) of the LNs on PET images and maximum short-axis diameter on transverse CT images. RESULTS The sensitivity and specificity of SiPM PET were 86.2% and 95.6%, respectively (cut-off SUVmax, 4.6). The area under the curve (AUC) of SiPM PET (0.977; 95% confidence interval [CI], 0.958-0.995) was significantly higher than that of non-SiPM PET (0.825; 95% CI 0.717-0.934) (P < 0.01). In a size-limited analysis of diameter, the AUC of SiPM PET (≥ 0.96 for all diameters) was significantly higher than that of non-SiPM PET (tended to decrease as the LN diameter decreased) for the diagnosis of LN metastasis by SUVmax. CONCLUSION SiPM PET had higher diagnostic accuracy for LN metastasis of oral SCC than non-SiPM PET, even for small LN metastasis without increasing false-positives.
Collapse
Affiliation(s)
- Ikuho Kojima
- Department of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan. .,Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
| | - Kentaro Takanami
- Department of Diagnostic Radiology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Takenori Ogawa
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology-Head and Neck Surgery, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology, Gifu University Hospital, 1-1 Yanagido, Gifu city, 501-1194, Japan
| | - Kenichiro Ishikawa
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology-Head and Neck Surgery, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Yohei Morishita
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Diagnostic Radiology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Ryo Ishii
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology-Head and Neck Surgery, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Akira Ohkoshi
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology-Head and Neck Surgery, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Ayako Nakanome
- Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Otolaryngology-Head and Neck Surgery, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Hayato Odagiri
- Department of Radiology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Masahiro Iikubo
- Department of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.,Head and Neck Cancer Center, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| |
Collapse
|
9
|
Huang K, Feng Y, Liang W, Li L. Impact of time of flight and point spread function on quantitative parameters of lung lesions in 18F-FDG PET/CT. BMC Med Imaging 2021; 21:169. [PMID: 34773998 PMCID: PMC8590319 DOI: 10.1186/s12880-021-00699-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 10/26/2021] [Indexed: 11/23/2022] Open
Abstract
Background Image reconstruction algorithm is one of the important factors affecting the quantitative parameters of PET/CT. The purpose of this study was to investigate the effects of time of flight (TOF) and point spread function (PSF) on quantitative parameters of lung lesions in 18F-FDG PET/CT. Methods This retrospective study evaluated 60 lung lesions in 39 patients who had undergone 18F-fluoro-deoxy-glucose (FDG) PET/CT. All lesions larger than 10 mm in diameter were included in the study. The PET data were reconstructed with a baseline ordered-subsets expectation–maximization (OSEM) algorithm, OSEM + PSF, OSEM + TOF and OSEM + TOF + PSF respectively. The differences of maximum standard uptake value (SUVmax), mean standard uptake value (SUVmean), metabolic tumor volume (MTV), total lesion glycolysis (TLG)and signal to noise ratio (SNR)were compared among different reconstruction algorithms. Results Compared with OSEM reconstruction, using OSEM + TOF + PSF increased SUVmean and SUVmax by 23.73% and 22.71% respectively, and SNR increased by 70.18%, MTV decreased by 23.84% (p < 0.01). The percentage difference was significantly higher in smaller lesions (diameter 10–22 mm) than in larger lesions (diameter 23–44 mm), and significantly higher in low contrast lesions (SNR ≤ 15.31) than in high contrast lesions (SNR > 15.31). The difference of TLG among various reconstruction algorithms is relatively small, the highest value is − 6.48% of OSEM + TOF + PSF, and the lowest value is 0.81% of OSEM + TOF. Conclusion TOF and PSF significantly affected the quantitative parameters of lung lesions in 18F-FDG PET/CT. OSEM + TOF + PSF can significantly increased SUVmax, SUVmean and SNR, and significantly reduce MTV, especially in small lesions and low contrast lesions. TLG can be relatively stable in different reconstruction algorithms.
Collapse
Affiliation(s)
- Kemin Huang
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China.
| | - Yanlin Feng
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| | - Weitang Liang
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| | - Lin Li
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| |
Collapse
|
10
|
Liu Y, Gao MJ, Zhou J, Du F, Chen L, Huang ZK, Hu JB, Lou C. Changes of [ 18F]FDG-PET/CT quantitative parameters in tumor lesions by the Bayesian penalized-likelihood PET reconstruction algorithm and its influencing factors. BMC Med Imaging 2021; 21:133. [PMID: 34530768 PMCID: PMC8444406 DOI: 10.1186/s12880-021-00664-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 09/05/2021] [Indexed: 11/10/2022] Open
Abstract
Background To compare the changes in quantitative parameters and the size and degree of 18F-fluorodeoxyglucose ([18F]FDG) uptake of malignant tumor lesions between Bayesian penalized-likelihood (BPL) and non-BPL reconstruction algorithms. Methods Positron emission tomography/computed tomography images of 86 malignant tumor lesions were reconstructed using the algorithms of ordered subset expectation maximization (OSEM), OSEM + time of flight (TOF), OSEM + TOF + point spread function (PSF), and BPL. [18F]FDG parameters of maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume (MTV), total lesion glycolysis (TLG), and signal-to-background ratio (SBR) of these lesions were measured. Quantitative parameters between the different reconstruction algorithms were compared, and correlations between parameter variation and lesion size or the degree of [18F]FDG uptake were analyzed. Results After BPL reconstruction, SUVmax, SUVmean, and SBR were significantly increased, MTV was significantly decreased. The difference values of %ΔSUVmax, %ΔSUVmean, %ΔSBR, and the absolute value of %ΔMTV between BPL and OSEM + TOF were 40.00%, 38.50%, 33.60%, and 33.20%, respectively, which were significantly higher than those between BPL and OSEM + TOF + PSF. Similar results were observed in the comparison of OSEM and OSEM + TOF + PSF with BPL. The %ΔSUVmax, %ΔSUVmean, and %ΔSBR were all significantly negatively correlated with the size and degree of [18F]FDG uptake in the lesions, whereas significant positive correlations were observed for %ΔMTV and %ΔTLG. Conclusion The BPL reconstruction algorithm significantly increased SUVmax, SUVmean, and SBR and decreased MTV of tumor lesions, especially in small or relatively hypometabolic lesions.
Collapse
Affiliation(s)
- Yao Liu
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Mei-Jia Gao
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Jie Zhou
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Fan Du
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Liang Chen
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Zhong-Ke Huang
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Ji-Bo Hu
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China
| | - Cen Lou
- Department of Nuclear Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Jianggan District, Hangzhou, 310000, Zhejiang, People's Republic of China.
| |
Collapse
|
11
|
Evaluation of Quantitative Ga-68 PSMA PET/CT Repeatability of Recurrent Prostate Cancer Lesions Using Both OSEM and Bayesian Penalized Likelihood Reconstruction Algorithms. Diagnostics (Basel) 2021; 11:diagnostics11061100. [PMID: 34208531 PMCID: PMC8233885 DOI: 10.3390/diagnostics11061100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 06/11/2021] [Accepted: 06/12/2021] [Indexed: 01/04/2023] Open
Abstract
Rationale: To formally determine the repeatability of Ga-68 PSMA lesion uptake in both relapsing and metastatic tumor. In addition, it was hypothesized that the BPL algorithm Q. Clear has the ability to lower SUV signal variability in the small lesions typically encountered in Ga-68 PSMA PET imaging of prostate cancer. Methods: Patients with biochemical recurrence of prostate cancer were prospectively enrolled in this single center pilot test-retest study and underwent two Ga-68 PSMA PET/CT scans within 7.9 days on average. Lesions were classified as suspected local recurrence, lymph node metastases or bone metastases. Two datasets were generated: one standard PSF + OSEM and one with PSF + BPL reconstruction algorithm. For tumor lesions, SUVmax was determined. Repeatability was formally assessed using Bland–Altman analysis for both BPL and standard reconstruction. Results: A total number of 65 PSMA-positive tumor lesions were found in 23 patients (range 1 to 12 lesions a patient). Overall repeatability in the 65 lesions was −1.5% ± 22.7% (SD) on standard reconstructions and −2.1% ± 29.1% (SD) on BPL reconstructions. Ga-68 PSMA SUVmax had upper and lower limits of agreement of +42.9% and −45.9% for standard reconstructions and +55.0% and −59.1% for BPL reconstructions, respectively (NS). Tumor SUVmax repeatability was dependent on lesion area, with smaller lesions exhibiting poorer repeatability on both standard and BPL reconstructions (F-test, p < 0.0001). Conclusion: A minimum response of 50% seems appropriate in this clinical situation. This is more than the recommended 30% for other radiotracers and clinical situations (PERCIST response criteria). BPL does not seem to lower signal variability in these cases.
Collapse
|
12
|
Usmani S, Ahmed N, Gnanasegaran G, Rasheed R, Marafi F, Alnaaimi M, Omar M, Musbah A, Al Kandari F, De Schepper S, Van den Wyngaert T. The clinical effectiveness of reconstructing 18F-sodium fluoride PET/CT bone using Bayesian penalized likelihood algorithm for evaluation of metastatic bone disease in obese patients. Br J Radiol 2021; 94:20210043. [PMID: 33571003 DOI: 10.1259/bjr.20210043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE A new Bayesian penalized likelihood reconstruction algorithm for positron emission tomography (PET) (Q.Clear) is now in clinical use for fludeoxyglucose (FDG) PET/CT. However, experience with non-FDG tracers and in special patient populations is limited. This pilot study aims to compare Q.Clear to standard PET reconstructions for 18F sodium fluoride (18F-NaF) PET in obese patients. METHODS 30 whole body 18F-NaF PET/CT scans (10 patients with BMI 30-40 Kg/m2 and 20 patients with BMI >40 Kg/m2) and a NEMA image quality phantom scans were analyzed using ordered subset expectation maximization (OSEM) and Q.Clear reconstructions methods with B400, 600, 800 and 1000. The images were assessed for overall image quality (IQ), noise level, background soft tissue, and lesion detectability, contrast recovery (CR), background variability (BV) and contrast-to-noise ratio (CNR) for both algorithms. RESULTS CNR for clinical cases was higher for Q.Clear than OSEM (p < 0.05). Mean CNR for OSEM was (21.62 ± 8.9), and for Q.Clear B400 (31.82 ± 14.6), B600 (35.54 ± 14.9), B800 (39.81 ± 16.1), and B1000 (40.9 ± 17.8). As the β value increased the CNR increased in all clinical cases. B600 was the preferred β value for reconstruction in obese patients. The phantom study showed Q.Clear reconstructions gave lower CR and lower BV than OSEM. The CNR for all spheres was significantly higher for Q.Clear (independent of β) than OSEM (p < 0.05), suggesting superiority of Q.Clear. CONCLUSION This pilot clinical study shows that Q.Clear reconstruction algorithm improves overall IQ of 18F-NaF PET in obese patients. Our clinical and phantom measurement results demonstrate improved CNR and reduced BV when using Q.Clear. A β value of 600 is preferred for reconstructing 18F-NaF PET/CT with Q.Clear in obese patients. ADVANCES IN KNOWLEDGE 18F-NaF PET/CT is less susceptible to artifacts induced by body habitus. Bayesian penalized likelihood reconstruction with18F-NaF PET improves overall IQ in obese patients.
Collapse
Affiliation(s)
- Sharjeel Usmani
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait.,Department of Nuclear Medicine, Jaber Al-Ahmad Molecular Imaging Center, Kuwait, Kuwait.,Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Najeeb Ahmed
- Cancer Research Group, Hull York Medical School, University of Hull, Hull, UK
| | | | - Rashid Rasheed
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait
| | - Fahad Marafi
- Department of Nuclear Medicine, Jaber Al-Ahmad Molecular Imaging Center, Kuwait, Kuwait
| | - Mashari Alnaaimi
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait
| | - Mohammad Omar
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait
| | - Ahmed Musbah
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait
| | - Fareeda Al Kandari
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Kuwait, Kuwait
| | - Stijn De Schepper
- Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Department of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium
| | - Tim Van den Wyngaert
- Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Department of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium
| |
Collapse
|
13
|
Wu Z, Guo B, Huang B, Zhao B, Qin Z, Hao X, Liang M, Xie J, Li S. Does the beta regularization parameter of bayesian penalized likelihood reconstruction always affect the quantification accuracy and image quality of positron emission tomography computed tomography? J Appl Clin Med Phys 2021; 22:224-233. [PMID: 33683004 PMCID: PMC7984479 DOI: 10.1002/acm2.13129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 09/13/2020] [Accepted: 11/24/2020] [Indexed: 11/27/2022] Open
Abstract
Purpose This study aims to provide a detailed investigation on the noise penalization factor in Bayesian penalized likelihood (BPL)‐based algorithm, with the utilization of partial volume effect correction (PVC), so as to offer the suitable beta value and optimum standardized uptake value (SUV) parameters in clinical practice for small pulmonary nodules. Methods A National Electrical Manufacturers Association (NEMA) image‐quality phantom was scanned and images were reconstructed using BPL with beta values ranged from 100 to 1000. The recovery coefficient (RC), contrast recovery (CR), and background variability (BV) were measured to assess the quantification accuracy and image quality. In the clinical assessment, lesions were categorized into sub‐centimeter (<10 mm, n = 7) group and medium size (10–30 mm, n = 16) group. Signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were measured to evaluate the image quality and lesion detectability. With PVC was performed, the impact of beta values on SUVs (SUVmax, SUVmean, SUVpeak) of small pulmonary nodules was evaluated. Subjective image analysis was performed by two experienced readers. Results With the increasing of beta values, RC, CR, and BV decreased gradually in the phantom work. In the clinical study, SNR and CNR of both groups increased with the beta values (P < 0.001), although the sub‐centimeter group showed increases after the beta value reached over 700. In addition, highly significant negative correlations were observed between SUVs and beta values for both lesion‐size groups before the PVC (P < 0.001 for all). After the PVC, SUVpeak measured from the sub‐centimeter group was no significantly different among different beta values (P = 0.830). Conclusion Our study suggests using SUVpeak as the quantification parameter with PVC performed to mitigate the effects of beta regularization. Beta values between 300 and 400 were preferred for pulmonary nodules smaller than 30 mm.
Collapse
Affiliation(s)
- Zhifang Wu
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
- Molecular Imaging Precision Medical Collaborative Innovation CenterShanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Binwei Guo
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Bin Huang
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Bin Zhao
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Zhixing Qin
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Xinzhong Hao
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Meng Liang
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Jun Xie
- Department of Biochemistry and Molecular BiologyShanxi Medical UniversityTaiyuanShanxiP.R. China
| | - Sijin Li
- Department of Nuclear MedicineFirst Hospital of Shanxi Medical UniversityTaiyuanShanxiP.R. China
- Molecular Imaging Precision Medical Collaborative Innovation CenterShanxi Medical UniversityTaiyuanShanxiP.R. China
| |
Collapse
|
14
|
Detection of sub-centimeter lesions using digital TOF-PET/CT system combined with Bayesian penalized likelihood reconstruction algorithm. Ann Nucl Med 2020; 34:762-771. [DOI: 10.1007/s12149-020-01500-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 07/01/2020] [Indexed: 12/19/2022]
|
15
|
The impact of time-of-flight, resolution recovery, and noise modelling in reconstruction algorithms in non-solid-state detectors PET/CT scanners: - multi-centric comparison of activity recovery in a 68Ge phantom. Phys Med 2020; 75:85-91. [PMID: 32559650 DOI: 10.1016/j.ejmp.2020.06.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 05/04/2020] [Accepted: 06/01/2020] [Indexed: 11/21/2022] Open
Abstract
The reconstruction algorithms implemented on PET/CT scanners offer gain in activity recovery of small lesions at an extent that is not full known yet. METHODS: A cylindrical phantom with warm background and hot spheres filled with a 68Ge epoxy was acquired with four non-state-solid-detectors PET/CT scanners: mCT, Ingenuity TF, Discovery 710, and IQ. Images were reconstructed switching on and off time-of-flight (TOF), point spread function (PSF) modelling, and Bayesian penalised likelihood (BPL). Images were reconstructed with the default parameters recommended by the manufacturers. The recovery coefficient (RCmax), defined as the ratio of the measured maximum activity concentration in each sphere and the actual one, and the coefficient of variation (CoVBAC) defined as the ratio of the standard deviation and the average of background activity concentration were measured. RESULTS: While with IR alone, complete recovery of the activity concentration is achieved down to the 22 mm diameter's sphere, with TOF, TOF + PSF and BPL it is achieved down to the 17 mm diameter one. At smaller dimensions, the difference among the various studied reconstruction algorithms is substantial for the 13- and 17-mm diameters' spheres for all scanners and for all reconstructions with a considerable gain in RCmax when PSF and BPL are used. At 10 mm diameter's sphere the difference among the algorithms is significantly reduced, except for BPL which still guarantees a gain in RCmax.
Collapse
|
16
|
Lowe G, Spottiswoode B, Declerck J, Sullivan K, Sharif MS, Wong WL, Sanghera B. Positron emission tomography PET/CT harmonisation study of different clinical PET/CT scanners using commercially available software. BJR Open 2020; 2:20190035. [PMID: 33178963 PMCID: PMC7594895 DOI: 10.1259/bjro.20190035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 04/30/2020] [Accepted: 05/04/2020] [Indexed: 11/06/2022] Open
Abstract
Objectives: Harmonisation is the process whereby standardised uptake values from different scanners can be made comparable. This PET/CT pilot study aimed to evaluate the effectiveness of harmonisation of a modern scanner with image reconstruction incorporating resolution recovery (RR) with another vendor older scanner operated in two-dimensional (2D) mode, and for both against a European standard (EARL). The vendor-proprietary software EQ•PET was used, which achieves harmonisation with a Gaussian smoothing. A substudy investigated effect of RR on harmonisation. Methods: Phantom studies on each scanner were performed to optimise the smoothing parameters required to achieve successful harmonisation. 80 patients were retrospectively selected; half were imaged on each scanner. As proof of principle, a cohort of 10 patients was selected from the modern scanner subjects to study the effects of RR on harmonisation. Results: Before harmonisation, the modern scanner without RR adhered to EARL specification. Using the phantom data, filters were derived for optimal harmonisation between scanners and with and without RR as applicable, to the EARL standard. The 80-patient cohort did not reveal any statistically significant differences. In the 10-patient cohort SUVmax for RR > no RR irrespective of harmonisation but differences lacked statistical significance (one-way ANOVA F(3.36) = 0.37, p = 0.78). Bland-Altman analysis showed that harmonisation reduced the SUVmax ratio between RR and no RR to 1.07 (95% CI 0.96–1.18) with no outliers. Conclusions: EQ•PET successfully enabled harmonisation between modern and older scanners and against the EARL standard. Harmonisation reduces SUVmax and dependence on the use of RR in the modern scanner. Advances in knowledge: EQ•PET is feasible to harmonise different PET/CT scanners and reduces the effect of RR on SUVmax.
Collapse
Affiliation(s)
- Gerry Lowe
- Cancer Centre, Mount Vernon Hospital, London, UK
| | | | | | - Keith Sullivan
- Health Research Methods Unit, University of Hertfordshire, Hertfordshire, UK
| | - Mhd Saeed Sharif
- School of Arch., Comp. and Eng., University of East London, London, UK
| | - Wai-Lup Wong
- Paul Strickland Scanner Centre, Mount Vernon Hospital, London, UK
| | - Bal Sanghera
- Paul Strickland Scanner Centre, Mount Vernon Hospital, London, UK
| |
Collapse
|
17
|
Wagatsuma K, Sakata M, Miwa K, Miyaji N. [10. Quantitative Measurement and Quality Control in Positron Emission Tomography]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:437-443. [PMID: 32307372 DOI: 10.6009/jjrt.2020_jsrt_76.4.437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Kei Wagatsuma
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Muneyuki Sakata
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Science, International University of Health and Welfare
| | - Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| |
Collapse
|
18
|
Rogasch JM, Suleiman S, Hofheinz F, Bluemel S, Lukas M, Amthauer H, Furth C. Reconstructed spatial resolution and contrast recovery with Bayesian penalized likelihood reconstruction (Q.Clear) for FDG-PET compared to time-of-flight (TOF) with point spread function (PSF). EJNMMI Phys 2020; 7:2. [PMID: 31925574 PMCID: PMC6954158 DOI: 10.1186/s40658-020-0270-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 01/02/2020] [Indexed: 02/06/2023] Open
Abstract
Background Bayesian penalized likelihood reconstruction for PET (e.g., GE Q.Clear) aims at improving convergence of lesion activity while ensuring sufficient signal-to-noise ratio (SNR). This study evaluated reconstructed spatial resolution, maximum/peak contrast recovery (CRmax/CRpeak) and SNR of Q.Clear compared to time-of-flight (TOF) OSEM with and without point spread function (PSF) modeling. Methods The NEMA IEC Body phantom was scanned five times (3 min scan duration, 30 min between scans, background, 1.5–3.9 kBq/ml F18) with a GE Discovery MI PET/CT (3-ring detector) with spheres filled with 8-, 4-, or 2-fold the background activity concentration (SBR 8:1, 4:1, 2:1). Reconstruction included Q.Clear (beta, 150/300/450), “PSF+TOF4/16” (iterations, 4; subsets, 16; in-plane filter, 2.0 mm), “OSEM+TOF4/16” (identical parameters), “PSF+TOF2/17” (2 it, 17 ss, 2.0 mm filter), “OSEM+TOF2/17” (identical), “PSF+TOF4/8” (4 it, 8 ss, 6.4 mm), and “OSEM+TOF2/8” (2 it, 8 ss, 6.4 mm). Spatial resolution was derived from 3D sphere activity profiles. RC as (sphere activity concentration [AC]/true AC). SNR as (background mean AC/background AC standard deviation). Results Spatial resolution of Q.Clear150 was significantly better than all conventional algorithms at SBR 8:1 and 4:1 (Wilcoxon, each p < 0.05). At SBR 4:1 and 2:1, the spatial resolution of Q.Clear300/450 was similar or inferior to PSF+TOF4/16 and OSEM+TOF4/16. Small sphere CRpeak generally underestimated true AC, and it was similar for Q.Clear150/300/450 as with PSF+TOF4/16 or PSF+TOF2/17 (i.e., relative differences < 10%). Q.Clear provided similar or higher CRpeak as OSEM+TOF4/16 and OSEM+TOF2/17 resulting in a consistently better tradeoff between CRpeak and SNR with Q.Clear. Compared to PSF+TOF4/8/OSEM+TOF2/8, Q.Clear150/300/450 showed lower SNR but higher CRpeak. Conclusions Q.Clear consistently improved reconstructed spatial resolution at high and medium SBR compared to PSF+TOF and OSEM+TOF, but only with beta = 150. However, this is at the cost of inferior SNR with Q.Clear150 compared to Q.Clear300/450 and PSF+TOF4/16/PSF+TOF2/17 while CRpeak for the small spheres did not improve considerably. This suggests that Q.Clear300/450 may be advantageous for the 3-ring detector configuration because the tradeoff between CR and SNR with Q.Clear300/450 was superior to PSF+TOF4/16, OSEM+TOF4/16, and OSEM+TOF2/17. However, it requires validation by systematic evaluation in patients at different activity and acquisition protocols.
Collapse
Affiliation(s)
- Julian M Rogasch
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany.
| | - Said Suleiman
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany
| | - Frank Hofheinz
- Helmholtz-Zentrum Dresden-Rossendorf, Institute for Radiopharmaceutical Cancer Research, Dresden, Germany
| | - Stephanie Bluemel
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany
| | - Mathias Lukas
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany
| | - Holger Amthauer
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany
| | - Christian Furth
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, Berlin, Germany
| |
Collapse
|
19
|
Zorz A, Matheoud R, Richetta E, Baichoo S, Poli M, Scaggion A, Pellerito RE, Cuppari L, Sacchetti GM, Stasi M, Paiusco M, Brambilla M. Performance evaluation of a new time of flight PET/CT scanner: Results of a multicenter study. Phys Med 2019; 68:146-154. [PMID: 31786482 DOI: 10.1016/j.ejmp.2019.11.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 11/14/2019] [Accepted: 11/18/2019] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The aim of this multicenter study was to evaluate the performance of the upgraded version of the Ingenuity TF PET/CT scanner, according to the NEMA NU-2 2012 standards. METHODS Spatial resolution, sensitivity, count rate response, scatter fraction, image quality and accuracy were evaluated on three Ingenuity TF scanners installed in Italian hospitals. Furthermore, energy and timing resolution were measured. A detailed image quality phantom analysis was performed to evaluate the effect of different clinical reconstruction parameters, including the application of PSF correction. RESULTS Results show an average spatial resolution of 4.7 mm and an average absolute system sensitivity of 7.9 cps/kBq. The average maximum NECR was 119.83 kcps at 20.67 kBq/ml, while the maximum true event rate was 322.62 kcps at the concentration of 24.51 kBq/ml. The average maximum bias below NECR peak was 12.58%. All the results of NEMA tests were in agreement with the values declared by the manufacturer. The estimated average energy and timing resolution were 10.83% and 536.2 ps, respectively. Image quality phantom analysis obtained with different reconstruction settings showed that PSF correction was the parameter that affected mainly on contrast recovery coefficient, while the iteration number and amplitude of Gaussian filter had no significant effect. Of relevance, the application of PSF correction never led to recovery coefficient values higher than 100% and to Gibbs or edge artifacts. CONCLUSIONS The new Ingenuity TF model shows physical performance similar to other scanners of the latest generation for all standard NEMA NU2-2012 measurements.
Collapse
Affiliation(s)
- Alessandra Zorz
- Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, via Gattamelata 64, Padua, Italy.
| | - Roberta Matheoud
- Medical Physics Department, AOU Maggiore della Carità, Corso Mazzini 18, Novara, Italy.
| | - Elisa Richetta
- Medical Physics Department, AO Ordine Mauriziano di Torino, Via Magellano 1, Turin, Italy.
| | - Saraswati Baichoo
- Dept. of Physics, University of Trieste, Via Tiepolo 11, Trieste, Italy; Abdus Salam International Centre for Theoretical Physic (ICTP), Strada Costiera 11, Trieste, Italy.
| | - Matteo Poli
- Medical Physics Department, AO Ordine Mauriziano di Torino, Via Magellano 1, Turin, Italy.
| | - Alessandro Scaggion
- Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, via Gattamelata 64, Padua, Italy.
| | | | - Lea Cuppari
- Nuclear Medicine Department, Veneto Institute of Oncology IOV - IRCCS, via Gattamelata 64, Padua, Italy.
| | - Gian Mauro Sacchetti
- Nuclear Medicine Department, AOU Maggiore della Carità, Corso Mazzini 18, Novara, Italy.
| | - Michele Stasi
- Medical Physics Department, AO Ordine Mauriziano di Torino, Via Magellano 1, Turin, Italy.
| | - Marta Paiusco
- Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, via Gattamelata 64, Padua, Italy.
| | - Marco Brambilla
- Medical Physics Department, AOU Maggiore della Carità, Corso Mazzini 18, Novara, Italy.
| |
Collapse
|
20
|
Murphy DJ, Royle L, Chalampalakis Z, Alves L, Martins N, Bassett P, Breen R, Nair A, Bille A, Chicklore S, Cook GJ, Subesinghe M. The effect of a novel Bayesian penalised likelihood PET reconstruction algorithm on the assessment of malignancy risk in solitary pulmonary nodules according to the British Thoracic Society guidelines. Eur J Radiol 2019; 117:149-155. [PMID: 31307640 DOI: 10.1016/j.ejrad.2019.06.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 05/21/2019] [Accepted: 06/09/2019] [Indexed: 11/17/2022]
Abstract
PURPOSE British Thoracic Society (BTS) guidelines advocate using FDG PET-CT with the Herder model to estimate malignancy risk in solitary pulmonary nodules (SPNs). Qualitative and semi-quantitative assessment of SPN uptake is based upon analysis of Ordered Subset Expected Maximisation (OSEM) PET images. Our aim was to assess the effect of a Bayesian Penalised Likelihood (BPL) PET reconstruction on the assessment of SPN FDG uptake and estimation of malignancy risk (Herder score). METHODS Subjects with SPNs who underwent FDG PET-CT between 2014-2017, with histological confirmation of malignancy or histological/imaging follow-up confirmation of benignity were included. Two blinded readers independently classified SPN uptake on both OSEM and BPL (BTS score; 1 = none; 2 = ≤ mediastinal blood pool (MBP); 3 = >MBP but ≤ 2x liver; 4 = >2x liver), with resultant calculation of the Herder score (%) for both reconstructions. RESULTS 97 subjects with 75 (77%) malignant SPNs were included. BPL increased the BTS score in 25 (26%) SPNs; 9 SPNs (7 malignant) increased from BTS score 2 to 3, 16 (13 malignant) from BTS score 3 to 4, with a mean Herder score increase of 18 ± 22%. The mean Herder score for all SPNs with BPL was higher than OSEM (73 ± 29 vs 68 ± 32%, p = 0.001). There was no difference in Herder model diagnostic performance between BPL and OSEM, with similar areas under the curve (0.84 vs 0.83, p = 0.39). CONCLUSION BPL increases the Herder score in 26% of SPNs compared to OSEM but does not alter the diagnostic performance of the Herder model.
Collapse
Affiliation(s)
- D J Murphy
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
| | - L Royle
- Department of Radiology, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - Z Chalampalakis
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK
| | - L Alves
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK
| | - N Martins
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK
| | | | - R Breen
- Department of Respiratory Medicine, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - A Nair
- Department of Radiology, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - A Bille
- Department of Cardiothoracic Surgery, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - S Chicklore
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - G J Cook
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - M Subesinghe
- King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, UK; Department of Cancer Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| |
Collapse
|
21
|
|