1
|
Liu X, Yin P, Li T, Yin Y, Li Z. Influence and optimization strategy of the magnetic field in 1.5 T MR-linac liver stereotactic radiotherapy. Radiat Oncol 2023; 18:162. [PMID: 37794505 PMCID: PMC10548616 DOI: 10.1186/s13014-023-02356-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 09/26/2023] [Indexed: 10/06/2023] Open
Abstract
OBJECTIVE To compare intensity reduction plans for liver cancer with or without a magnetic field and optimize field and subfield numbers in the intensity-modulated radiotherapy (IMRT) plans designed for liver masses in different regions. METHODS This retrospective study included 62 patients who received radiotherapy for liver cancer at Shandong Cancer Hospital. Based on each patient's original individualized intensity-modulated plan (plan1.5 T), a magnetic field-free plan (plan0 T) and static intensity-modulated plan with four different optimization schemes were redesigned for each patient. The differences in dosimetric parameters among plans were compared. RESULTS In the absence of a magnetic field in the first quadrant, PTV Dmin increased (97.75 ± 17.55 vs. 100.96 ± 22.78)%, Dmax decreased (121.48 ± 29.68 vs. 119.06 ± 28.52)%, D98 increased (101.35 ± 7.42 vs. 109.35 ± 26.52)% and HI decreased (1.14 ± 0.14 vs. 1.05 ± 0.01). In the absence of a magnetic field in the second quadrant, PTV Dmin increased (84.33 ± 19.74 vs. 89.96 ± 21.23)%, Dmax decreased (105 ± 25.08 vs. 104.05 ± 24.86)%, and HI decreased (1.04 ± 0.25 vs. 0.99 ± 0.24). In the absence of a magnetic field in the third quadrant, PTV Dmax decreased (110.21 ± 2.22 vs. 102.31 ± 26)%, L-P V30 decreased (10.66 ± 9.19 vs. 5.81 ± 3.22)%, HI decreased (1.09 ± 0.02 vs. 0.98 ± 0.25), and PTV Dmin decreased (92.12 ± 4.92 vs. 89.1 ± 22.35)%. In the absence of a magnetic field in the fourth quadrant, PTV Dmin increased (89.78 ± 6.72 vs. 93.04 ± 4.86)%, HI decreased (1.09 ± 0.01 vs. 1.05 ± 0.01) and D98 increased (99.82 ± 0.82 vs. 100.54 ± 0.84)%. These were all significant differences. In designing plans for tumors in each liver region, a total number of subfields in the first area of 60, total subfields in the second zone of 80, and total subfields in the third and fourth zones of 60 or 80 can achieve the dose effect without a magnetic field. CONCLUSION In patients with liver cancer, the effect of a magnetic field on the target dose is more significant than that on doses to organs at risk. By controlling the max total number of subfields in different quadrants, the effect of the magnetic field can be greatly reduced or even eliminated.
Collapse
Affiliation(s)
- Xin Liu
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, China
- Department of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, 250117, China
| | - Peijun Yin
- Department of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, 250117, China
| | - Tengxiang Li
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China
| | - Yong Yin
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, China.
- Department of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, 250117, China.
| | - Zhenjiang Li
- Department of Radiation Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, 250117, China.
| |
Collapse
|
2
|
Tanaka K, Suzuki J. The effect of vibration generated by demolition work on irradiation position accuracy of stereotactic radiotherapy system. J Appl Clin Med Phys 2022; 23:e13659. [PMID: 35643924 PMCID: PMC9512358 DOI: 10.1002/acm2.13659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 04/08/2022] [Accepted: 05/08/2022] [Indexed: 11/20/2022] Open
Abstract
Purpose One existing building, adjacent to the radiotherapy building, where stereotactic radiation was done, was to be demolished to give space for the construction of a new building. However, we were concerned that the vibrations generated by this demolition work, which occurred within 2 m from the radiotherapy building, would affect the radiation position accuracy of the radiotherapy machine. Methods To determine whether radiotherapy could be performed safely during the demolition period, we performed simulation tests involving the vibrations generated during demolition, measured these vibrations, and verified their effect on the irradiation position accuracy of the stereotactic radiotherapy system. For effective evaluations, tests were conducted assuming the maximum vibrations that could occur during actual demolition work. Results The maximum displacement of the vibrations generated by the simulated demolition work was 3.30 µm on the floor of the treatment room and 4.68 µm at the ceiling. Conclusions The results of the vibration measurements exceeded the limits of the criteria applicable to the electron beam system. However, the accuracy of the irradiation position of the stereotactic radiotherapy system remained unchanged during these vibrations. Therefore, the vibrations had no impact on radiotherapy safety, and radiotherapy was continued during the demolition work while coordinating with the demolition workers as necessary.
Collapse
Affiliation(s)
- Kaname Tanaka
- Department of Radiation Therapy Toyota Memorial Hospital Toyota Japan
| | - Junji Suzuki
- Department of Radiation Therapy Toyota Memorial Hospital Toyota Japan
| |
Collapse
|
3
|
Panizza D, Faccenda V, Lucchini R, Daniotti MC, Trivellato S, Caricato P, Pisoni V, De Ponti E, Arcangeli S. Intrafraction Prostate Motion Management During Dose-Escalated Linac-Based Stereotactic Body Radiation Therapy. Front Oncol 2022; 12:883725. [PMID: 35463373 PMCID: PMC9021501 DOI: 10.3389/fonc.2022.883725] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 03/15/2022] [Indexed: 11/13/2022] Open
Abstract
Background Extreme hypofractionation requires tight planning margins, high dose gradients, and strict adherence to planning criteria in terms of patient positioning and organ motion mitigation. This study reports the first clinical experience worldwide using a novel electromagnetic (EM) tracking device for intrafraction prostate motion management during dose-escalated linac-based stereotactic body radiation therapy (SBRT). Methods Thirteen patients with organ-confined prostate cancer underwent dose-escalated SBRT using flattening filter-free (FFF) volumetric modulated arc therapy (VMAT). The EM tracking device consisted of an integrated Foley catheter with a transmitter. Patients were simulated and treated with a filled bladder and an empty rectum. Setup accuracy was achieved by ConeBeam-CT (CBCT) matching, and motion was tracked during all the procedure. Treatment was interrupted when the signals exceeded a 2 mm threshold in any of the three spatial directions and, unless the offset was transient, target position was re-defined by repeating CBCT. Moreover, the displacements that would have occurred without any intrafraction organ motion management (i.e. no interruptions and repositionings) were simulated. Results In 31 out of 56 monitored fractions (55%), no intervention was required to correct the target position. In 25 (45%) a correction was mandated, but only in 10 (18%), the beam delivery was interrupted. Total treatment time lasted on average 10.2 minutes, 6.7 minutes for setup, and 3.5 minutes for beam delivery. Without any intrafraction motion management, the overall mean treatment time and the mean delivery time would have been 6.9 minutes and 3.2 minutes, respectively. The prostate would have been found outside the tolerance in 8% of the total session time, in 4% of the time during the setup, and in 14% during the beam-on phase. Predominant motion pattern was posterior and its probability increased with time, with a mean motion ≤ 2 mm occurring within 10 minutes. Conclusions EM real-time tracking was successfully implemented for intrafraction motion management during dose-escalated prostate SBRT. Results showed that most of the observed displacements were < 2 mm in any direction; however, there were a non-insignificant number of fractions with motion exceeding the predefined threshold, which would have otherwise gone undetected without intrafraction motion management.
Collapse
Affiliation(s)
- Denis Panizza
- Medical Physics Department, ASST Monza, Monza, Italy.,School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Valeria Faccenda
- Medical Physics Department, ASST Monza, Monza, Italy.,Department of Physics, University of Milan, Milan, Italy
| | - Raffaella Lucchini
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy.,Radiation Oncology Department, ASST Monza, Monza, Italy
| | - Martina Camilla Daniotti
- Medical Physics Department, ASST Monza, Monza, Italy.,Department of Physics, University of Milan, Milan, Italy
| | | | - Paolo Caricato
- Medical Physics Department, ASST Monza, Monza, Italy.,Department of Physics, University of Milan, Milan, Italy
| | | | - Elena De Ponti
- Medical Physics Department, ASST Monza, Monza, Italy.,School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, Milan, Italy.,Radiation Oncology Department, ASST Monza, Monza, Italy
| |
Collapse
|
4
|
Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance. Phys Med 2021; 91:121-130. [PMID: 34785490 DOI: 10.1016/j.ejmp.2021.10.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/10/2021] [Accepted: 10/30/2021] [Indexed: 11/21/2022] Open
Abstract
PURPOSE We developed an x-ray-opaque-marker (XOM) system with inserted fiducial markers for patient-specific quality assurance (QA) in CyberKnife (Accuray) and a general-purpose linear accelerator (linac). The XOM system can be easily inserted or removed from the existing patient-specific QA phantom. Our study aimed to assess the utility of the XOM system by evaluating the recognition accuracy of the phantom position error and estimating the dose perturbation around a marker. METHODS The recognition accuracy of the phantom position error was evaluated by comparing the known error values of the phantom position with the values measured by matching the images with target locating system (TLS; Accuray) and on-board imager (OBI; Varian). The dose perturbation was evaluated for 6 and 10 MV single-photon beams through experimental measurements and Monte Carlo simulations. RESULTS The root mean squares (RMSs) of the residual position errors for the recognition accuracy evaluation in translations were 0.07 mm with TLS and 0.30 mm with OBI, and those in rotations were 0.13° with TLS and 0.15° with OBI. The dose perturbation was observed within 1.5 mm for 6 MV and 2.0 mm for 10 MV from the marker. CONCLUSIONS Sufficient recognition accuracy of the phantom position error was achieved using our system. It is unnecessary to consider the dose perturbation in actual patient-specific QA. We concluded that the XOM system can be utilized to ensure quantitative and accurate phantom positioning in patient-specific QA with CyberKnife and a general-purpose linac.
Collapse
|
5
|
Kafaei P, Cappart Q, Renaud MA, Chapados N, Rousseau LM. Graph neural networks and deep reinforcement learning for simultaneous beam orientation and trajectory optimization of Cyberknife. Phys Med Biol 2021; 66. [PMID: 34592726 DOI: 10.1088/1361-6560/ac2bb5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 09/30/2021] [Indexed: 11/12/2022]
Abstract
Objective. Despite the high-quality treatment, the long treatment time of the Cyberknife system is believed to be a drawback. The high flexibility of its robotic arm requires meticulous path-finding algorithms to deliver the prescribed dose in the shortest time.Approach. We proposed a Deep Q-learning based on Graph Neural Networks to find the subset of the beams and the order to traverse them. A complex reward function is defined to minimize the distance covered by the robotic arm while avoiding the selection of close beams. Individual beam scores are also generated based on their effect on the beam intensity and are incorporated in the reward function. Main results. The performance of the presented method is evaluated on three clinical cases suffering from lung cancer. Applying this approach leads to an average of 35% reduction in the treatment time while delivering the prescribed dose provided by the physicians.Significance. Shorter treatment times result in a better treatment experience for individual patients, reduces discomfort and the sides effects of inadvertent movements for them. Additionally, it creates the opportunity to treat a higher number of patients in a given time period at the radiation therapy centers.
Collapse
Affiliation(s)
- Peyman Kafaei
- Department of Mathematics and Industrial Engineering, Polytechnique Montreal, Montreal, Canada.,CIRRELT-Interuniversity Research Center on Enterprise Networks, Logistics and Transportation, Montreal, Canada
| | - Quentin Cappart
- CIRRELT-Interuniversity Research Center on Enterprise Networks, Logistics and Transportation, Montreal, Canada.,Department of Computer Engineering and Software Engineering, Polytechnique Montreal, Montreal, Canada
| | - Marc-Andre Renaud
- Department of Mathematics and Industrial Engineering, Polytechnique Montreal, Montreal, Canada.,CIRRELT-Interuniversity Research Center on Enterprise Networks, Logistics and Transportation, Montreal, Canada
| | - Nicolas Chapados
- Department of Mathematics and Industrial Engineering, Polytechnique Montreal, Montreal, Canada
| | - Louis-Martin Rousseau
- Department of Mathematics and Industrial Engineering, Polytechnique Montreal, Montreal, Canada.,CIRRELT-Interuniversity Research Center on Enterprise Networks, Logistics and Transportation, Montreal, Canada
| |
Collapse
|
6
|
Masi L, Hernandez V, Saez J, Doro R, Livi L. Robotic MLC-based plans: A study of plan complexity. Med Phys 2021; 48:942-952. [PMID: 33332628 DOI: 10.1002/mp.14667] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 11/10/2020] [Accepted: 12/08/2020] [Indexed: 12/19/2022] Open
Abstract
PURPOSE The utility of complexity metrics has been assessed for IMRT and VMAT treatment plans, but this analysis has never been performed for CyberKnife (CK) plans. The purpose of this study is to perform a complexity analysis of CK MLC plans, adapting and computing complexity indices previously defined for IMRT plans. Metrics were used to compare the complexity of plans created by two optimization systems and to study correlations between plan complexity and patient-specific quality assurance (PSQA) results. Relationships between pairs of metrics were also analyzed to get insight into possible interdependencies. METHODS Two independent in-house software platforms were developed to compute six complexity metrics: modulation complexity score (MCS), edge metric (EM), plan irregularity (PI), plan modulation (PM), leaf gap (LG), and small aperture score (SAS10). MCS and PM definitions were adapted to account for CK plans characteristics. The computed metrics were used to compare the existing optimization algorithms (sequential and VOLO) in terms of plan complexity over 24 selected cases. Metrics were then computed over a large number (103) of VOLO SBRT clinical plans from different treatment sites, mainly liver, prostate, pancreas, and spine. Pearson's r was used to study relationships between each pair of metrics. Correlation between complexity indices and PSQA results expressed as gamma index passing rates (GPR) at (3%, 1 mm) and (2%, 1 mm) was finally analyzed. Correlation was regarded as weak for absolute Pearson's r values in the range 0.2-0.39, moderate 0.4-0.59, strong 0.6-0.79, and very strong 0.8-1. RESULTS When compared to VOLO, sequential plans exhibited a higher complexity degree, showing lower MCS and LG values and higher EM, PM and PI values. Differences were significant for 5/6 metrics (Wilcoxon P < 0.05). The analysis of VOLO clinical plans highlighted different degrees of complexity among plans from different treatment sites, increasing from liver to prostate, pancreas, and finally, spine. Analysis of dependencies between pairs of metrics showed a very strong significant negative correlation (P < 0.01), respectively, between MCS and PM (r = -0.97), and EM and LG (-0.82). Most of the remaining pairs showed moderate to strong correlations with the exception of PI, which showed weaker correlations with the other metrics. A moderate significant correlation was observed with GPR values both at (3%, 1 mm) and (2%, 1 mm) for all metrics except PI, which showed no correlation. CONCLUSIONS Modulation complexity metrics were computed for CK MLC-based plans for the first time and some metrics' definitions were adapted to CK plans peculiarities. The computed metrics proved a useful tool for comparing optimization algorithms and for characterizing CK clinical plans. Strong and very strong correlations were found between some pairs of metrics. Some significant correlations were found with PSQA GPR, indicating that some indices are promising for rationalizing and reducing PSQA workload. Our results set the basis for evaluating new optimization algorithms and TPS versions in the future, as well as for comparing the complexity of CK MLC-based plans in multicenter and multiplatform comparisons.
Collapse
Affiliation(s)
- Laura Masi
- Department of Medical Physics, Radiation Oncology IFCA, Florence, 50139, Italy
| | - Victor Hernandez
- Department of Medical Physics, Hospital Universitari Sant Joan de Reus, IISPV, Tarragona, 43204, Spain
| | - Jordi Saez
- Department of Radiation Oncology, Hospital Clinic de Barcelona, Barcelona, 08036, Spain
| | - Raffaela Doro
- Department of Medical Physics, Radiation Oncology IFCA, Florence, 50139, Italy
| | - Lorenzo Livi
- Radiotherapy Unit AOU Careggi, Florence, 50139, Italy.,Department of Experimental and Clinical Biomedical Sciences 'Mario Serio', University of Florence, Florence, 50139, Italy
| |
Collapse
|
7
|
Hernandez V, Hansen CR, Widesott L, Bäck A, Canters R, Fusella M, Götstedt J, Jurado-Bruggeman D, Mukumoto N, Kaplan LP, Koniarová I, Piotrowski T, Placidi L, Vaniqui A, Jornet N. What is plan quality in radiotherapy? The importance of evaluating dose metrics, complexity, and robustness of treatment plans. Radiother Oncol 2020; 153:26-33. [PMID: 32987045 DOI: 10.1016/j.radonc.2020.09.038] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/17/2020] [Accepted: 09/17/2020] [Indexed: 12/25/2022]
Abstract
Plan evaluation is a key step in the radiotherapy treatment workflow. Central to this step is the assessment of treatment plan quality. Hence, it is important to agree on what we mean by plan quality and to be fully aware of which parameters it depends on. We understand plan quality in radiotherapy as the clinical suitability of the delivered dose distribution that can be realistically expected from a treatment plan. Plan quality is commonly assessed by evaluating the dose distribution calculated by the treatment planning system (TPS). Evaluating the 3D dose distribution is not easy, however; it is hard to fully evaluate its spatial characteristics and we still lack the knowledge for personalising the prediction of the clinical outcome based on individual patient characteristics. This advocates for standardisation and systematic collection of clinical data and outcomes after radiotherapy. Additionally, the calculated dose distribution is not exactly the dose delivered to the patient due to uncertainties in the dose calculation and the treatment delivery, including variations in the patient set-up and anatomy. Consequently, plan quality also depends on the robustness and complexity of the treatment plan. We believe that future work and consensus on the best metrics for quality indices are required. Better tools are needed in TPSs for the evaluation of dose distributions, for the robust evaluation and optimisation of treatment plans, and for controlling and reporting plan complexity. Implementation of such tools and a better understanding of these concepts will facilitate the handling of these characteristics in clinical practice and be helpful to increase the overall quality of treatment plans in radiotherapy.
Collapse
Affiliation(s)
- Victor Hernandez
- Department of Medical Physics, Hospital Sant Joan de Reus, IISPV, Spain.
| | - Christian Rønn Hansen
- Laboratory of Radiation Physics, Odense University Hospital, Denmark; Institute of Clinical Research, University of Southern Denmark, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Denmark
| | | | - Anna Bäck
- Department of Therapeutic Radiation Physics, Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at the University of Gothenburg, Sweden
| | - Richard Canters
- Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, The Netherlands
| | - Marco Fusella
- Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
| | - Julia Götstedt
- Department of Radiation Physics, University of Gothenburg, Göteborg, Sweden
| | - Diego Jurado-Bruggeman
- Medical Physics and Radiation Protection Department, Institut Català d'Oncologia, Girona, Spain
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied Therapy, Graduate, School of Medicine, Kyoto University, Japan
| | | | - Irena Koniarová
- National Radiation Protection Institute, Prague, Czech Republic
| | - Tomasz Piotrowski
- Department of Electroradiology, Poznań University of Medical Sciences, Poznań, Poland; Department of Medical Physics, Greater Poland Cancer Centre, Poznań, Poland
| | - Lorenzo Placidi
- Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Roma, Italy
| | - Ana Vaniqui
- Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, The Netherlands
| | - Nuria Jornet
- Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| |
Collapse
|
8
|
Kawata K, Kamomae T, Oguchi H, Kawabata F, Okudaira K, Kawamura M, Ohtakara K, Itoh Y, Naganawa S. Evaluation of newly implemented dose calculation algorithms for multileaf collimator-based CyberKnife tumor-tracking radiotherapy. Med Phys 2020; 47:1391-1403. [PMID: 31913508 DOI: 10.1002/mp.14013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 12/30/2019] [Accepted: 12/30/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In the previous treatment planning system (TPS) for CyberKnife (CK), multileaf collimator (MLC)-based treatment plans could be created only by using the finite-size pencil beam (FSPB) algorithm. Recently, a new TPS, including the FSPB with lateral scaling option (FSPB+) and Monte Carlo (MC) algorithms, was developed. In this study, we performed basic and clinical end-to-end evaluations for MLC-based CK tumor-tracking radiotherapy using the MC, FSPB+, and FSPB. METHODS Water- and lung-equivalent slab phantoms were combined to obtain the percentage depth dose (PDD) and off-center ratio (OCR). The CK M6 system and Precision TPS were employed, and PDDs and OCRs calculated by the MC, FSPB+, and FSPB were compared with the measured doses obtained for 30.8 × 30.8 mm2 and 60.0 × 61.6 mm2 fields. A lung motion phantom was used for clinical evaluation and MLC-based treatment plans were created using the MC. The doses were subsequently recalculated using the FSPB+ and FSPB, while maintaining the irradiation parameters. The calculated doses were compared with the doses measured using a microchamber (for target doses) or a radiochromic film (for dose profiles). The dose volume histogram (DVH) indices were compared for all plans. RESULTS In homogeneous and inhomogeneous phantom geometries, the PDDs calculated by the MC and FSPB+ agreed with the measurements within ±2.0% for the region between the surface and a depth of 250 mm, whereas the doses calculated by the FSPB in the lung-equivalent phantom region were noticeably higher than the measurements, and the maximum dose differences were 6.1% and 4.4% for the 30.8 × 30.8 mm2 and 60.0 × 61.6 mm2 fields, respectively. The maximum distance to agreement values of the MC, FSPB+, and FSPB at the penumbra regions of OCRs were 1.0, 0.6, and 1.1 mm, respectively, but the best agreement was obtained between the MC-calculated curve and measurements at the boundary of the water- and lung-equivalent slabs, compared with those of the FSPB+ and FSPB. For clinical evaluations using the lung motion phantom, under the static motion condition, the dose errors measured by the microchamber were -1.0%, -1.9%, and 8.8% for MC, FSPB+, and FSPB, respectively; their gamma pass rates for the 3%/2 mm criterion comparing to film measurement were 98.4%, 87.6%, and 31.4% respectively. Under respiratory motion conditions, there was no noticeable decline in the gamma pass rates. In the DVH indices, for most of the gross tumor volume and planning target volume, significant differences were observed between the MC and FSPB, and between the FSPB+ and FSPB. Furthermore, significant differences were observed for lung Dmean , V15 Gy , and V20 Gy between the MC, FSPB+, and FSPB. CONCLUSIONS The results indicate that the doses calculated using the MC and FSPB+ differed remarkably in inhomogeneous regions, compared with the FSPB. Because the MC was the most consistent with the measurements, it is recommended for final dose calculations in inhomogeneous regions such as the lung. Furthermore, the sufficient accuracy of dose delivery using MLC-based tumor-tracking radiotherapy by CK was demonstrated for clinical implementation.
Collapse
Affiliation(s)
- Kohei Kawata
- Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 461-8673, Japan
| | - Takeshi Kamomae
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan
| | - Hiroshi Oguchi
- Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 461-8673, Japan
| | - Fumitaka Kawabata
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Aichi, 466-8560, Japan
| | - Kuniyasu Okudaira
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Aichi, 466-8560, Japan
| | - Mariko Kawamura
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan
| | - Kazuhiro Ohtakara
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan
| | - Yoshiyuki Itoh
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan
| |
Collapse
|
9
|
Calusi S, Doro R, Di Cataldo V, Cipressi S, Francolini G, Bonucci I, Livi L, Masi L. Performance assessment of a new optimization system for robotic SBRT MLC-based plans. Phys Med 2020; 71:31-38. [DOI: 10.1016/j.ejmp.2020.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 02/07/2020] [Accepted: 02/13/2020] [Indexed: 12/14/2022] Open
|
10
|
Biston MC, Dupuis P, Gassa F, Grégoire V. Do all the linear accelerators comply with the ICRU 91's constraints for stereotactic body radiation therapy treatments? Cancer Radiother 2019; 23:625-629. [PMID: 31447346 DOI: 10.1016/j.canrad.2019.07.137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 07/11/2019] [Indexed: 11/17/2022]
Abstract
Recent technological developments in linear accelerators (linacs) and their imaging systems have made it possible to routinely perform stereotactic radiotherapy (SRT) treatments. To ensure the security and quality of the treatments, national and international recommendations have been written. This review focuses on the recommendations of the report 91 of the International Commission on Radiation Units (ICRU) on stereotactic treatments with small photon beams and proposes to answer the question of the eligibility of the commercially available accelerators for the treatment of extra-cranial SRT (SBRT). The ICRU 91 report outlines important features needed to respect the constraints, which are high intensity photon beam, integrated image-guidance, high mechanical accuracy of the linac, multileaf collimator with reduced leaf width, bundled motion management and bundled 6 Dimensional "robotic" couch tabletop. Most of the contemporary linacs meet these recommendations, in particular, stereotactic dedicated linacs, or modern gantry-based linacs equipped with 3 dimensional cone-beam CT imaging and 2D-stereoscopic planar imaging. Commercially available ring-based linacs have some limitations: they offer only coplanar treatments, and couch movements are limited to translations and, some have limited imaging equipment and no ability to manage intrafraction motion. However, for performing SBRT, non-coplanar irradiations are not mandatory, contrarily to intracranial stereotactic irradiations. Furthermore, patients' rotations can be corrected, thanks to real-time adaptive radiotherapy available on MRI-linacs. Finally, significant improvements are expected in the short term to compensate the weaknesses of the current devices.
Collapse
Affiliation(s)
- M C Biston
- Léon Bérard Cancer Center, University of Lyon, 69373 Lyon, France; Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA, 69622 Lyon, France.
| | - P Dupuis
- Léon Bérard Cancer Center, University of Lyon, 69373 Lyon, France
| | - F Gassa
- Léon Bérard Cancer Center, University of Lyon, 69373 Lyon, France
| | - V Grégoire
- Léon Bérard Cancer Center, University of Lyon, 69373 Lyon, France
| |
Collapse
|
11
|
Novel inverse planning optimization algorithm for robotic radiosurgery: First clinical implementation and dosimetric evaluation. Phys Med 2019; 64:230-237. [DOI: 10.1016/j.ejmp.2019.07.020] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 07/23/2019] [Accepted: 07/25/2019] [Indexed: 12/31/2022] Open
|
12
|
Posiewnik M, Piotrowski T. A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer. Phys Med 2019; 59:13-21. [DOI: 10.1016/j.ejmp.2019.02.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 01/29/2019] [Accepted: 02/15/2019] [Indexed: 11/26/2022] Open
|