• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4681887)   Today's Articles (608)
For: Goto M, Tominaga C, Taura M, Azumi H, Sato K, Homma N, Mori I. A method to measure slice sensitivity profiles of CT images under low-contrast and high-noise conditions. Phys Med 2019;60:100-110. [PMID: 31000069 DOI: 10.1016/j.ejmp.2019.03.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2018] [Revised: 03/03/2019] [Accepted: 03/11/2019] [Indexed: 11/17/2022]  Open
Number Cited by Other Article(s)
1
Hoyoshi K, Sato K, Homma N, Mori I. Noise-related inaccuracies in the quantitative evaluation of CT artifacts. Radiol Phys Technol 2025;18:157-171. [PMID: 39776374 DOI: 10.1007/s12194-024-00869-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 11/05/2024] [Accepted: 11/26/2024] [Indexed: 01/11/2025]
2
Tsuda N, Mitsui K. [Evaluation of Noise Properties at Nonuniformity Area and Resolution Properties of CT Image Using Iterative Reconstruction Method]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022;78:809-818. [PMID: 35732411 DOI: 10.6009/jjrt.2022-1247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
3
Fukushima Y, Matsuda A, Koizumi K, Honda M, Masamoto K, Fujibayashi S. Usefulness of model-based iterative reconstruction in low-dose lumbar spine CT after spine surgery with metal implant: a phantom study. Acta Radiol 2021;62:1333-1340. [PMID: 33019801 DOI: 10.1177/0284185120961424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
4
Goto M. [6. Image Quality of Iterative Reconstruction Algorithms]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021;77:612-621. [PMID: 34148904 DOI: 10.6009/jjrt.2021_jsrt_77.6.612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
5
Narita A, Ohkubo M, Fukaya T, Noto Y. Technical Note: A simple method for measuring the slice sensitivity profile of iteratively reconstructed CT images using a non-slanted edge plane. Med Phys 2021;48:1125-1130. [PMID: 33332583 DOI: 10.1002/mp.14668] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 11/24/2020] [Accepted: 12/08/2020] [Indexed: 11/12/2022]  Open
6
Monnin P, Viry A, Verdun FR, Racine D. Slice NEQ and system DQE to assess CT imaging performance. ACTA ACUST UNITED AC 2020;65:105009. [DOI: 10.1088/1361-6560/ab807a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA