1
|
Bastiaannet R, Lin M, Frey EC, de Jong HW. Intraprocedural C-arm dual-phase cone-beam enhancement patterns correlate with tumor absorbed dose after radioembolization. Med Phys 2024; 51:3045-3052. [PMID: 38064591 PMCID: PMC10994751 DOI: 10.1002/mp.16882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 11/17/2023] [Accepted: 11/17/2023] [Indexed: 04/05/2024] Open
Abstract
BACKGROUND Recent studies have shown a clear relationship between absorbed dose and tumor response to treatment after hepatic radioembolization. These findings help to create more personalized treatment planning and dosimetry. However, crucial to this goal is the ability to predict the dose distribution prior to treatment. The microsphere distribution is ultimately determined by (i) the hepatic vasculature and the resulting blood flow dynamics and (ii) the catheter position. PURPOSE To show that pretreatment, intra-procedural imaging of blood flow patterns, as quantified by catheter-directed intra-arterial contrast enhancement, correlate with posttreatment microsphere accumulation and, consequently, absorbed dose. MATERIALS AND METHODS Patients who participated in a clinical trial (NCT01177007) and for whom both a pretreatment dual-phase contrast-enhanced cone-beam CT (CBCT) and a posttreatment 90Y PET/CT scan were available were included in this retrospective study. Tumors and perfused volumes were manually delineated on the CBCT by an experienced radiologist. The mean, sum, and standard deviation of the voxels in each volume were recorded. The delineations were transferred to the PET-based absorbed dose maps by coregistration of the corresponding CTs. Linear multiple regression was used to correlate pretreatment CBCT enhancement to posttreatment 90Y PET/CT-based absorbed dose in each region. Leave-one-out cross-validation and Bland-Altman analyses were performed on the predicted versus measured absorbed doses. RESULTS Nine patients, with a total of 23 tumors were included. All presented with hepatocellular carcinoma (HCC). Visually, all patients had a clear correspondence between CBCT enhancement and absorbed dose. The correlation between CBCT enhancement and posttherapy absorbed tumor dose based was strong (R2 = 0.91), and moderate for the non-tumor liver tissue (R2 = 0.61). Limits of agreement were approximately ±55 Gray for tumor tissue. CONCLUSION There is a linear relationship between pretreatment blood dynamics in HCC tumors and posttreatment absorbed dose, which, if shown to be generalizable, allows for pretreatment tumor absorbed dose prediction.
Collapse
Affiliation(s)
- Remco Bastiaannet
- The Russell H Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, MD, United States
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - MingDe Lin
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, United States
| | - Eric C. Frey
- The Russell H Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, MD, United States
| | - Hugo W.A.M. de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
2
|
Noipinit N, Sukprakun C, Siricharoen P, Khamwan K. Comparison of absorbed doses to the tumoral and non-tumoral liver in HCC patients undergoing 99mTc-MAA and 90Y-microspheres radioembolization. Ann Nucl Med 2024; 38:210-218. [PMID: 38142421 DOI: 10.1007/s12149-023-01890-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 11/26/2023] [Indexed: 12/26/2023]
Abstract
PURPOSE This study aimed to determine the absorbed doses in the tumoral-liver and non-tumoral liver of hepatocellular carcinoma (HCC) patients undergoing radioembolization with Yttrium-90 (90Y) resin microspheres, and compared with those derived from 99mTc-MAA using the partition model. METHODS A total of 42 HCC patients (28 males and 14 females, mean age 65 ± 11.51 years) who received 45 treatment sessions with 90Y-microspheres between 2016 and 2021 were included. Pre-treatment 99mTc-MAA and post-treatment 90Y-bremsstrahlung SPECT/CT were acquired for each patient. Semi-automated segmentation of regions of interest (ROIs) was performed using MIM Encore software to determine the tumor-liver ratio (TLR) encompassing the liver volume, tumoral-liver, and lungs, and verified by both nuclear medicine physician and interventional radiologist. A partition dosimetry model was used to estimate the administered activity of 90Y-microspheres and the absorbed doses to the tumoral-liver and non-tumoral liver. The student's paired t test and Bland-Altman plot were used for the statistical analysis. RESULTS The mean TLR values obtained from 99mTc-MAA SPECT/CT and 90Y-bremsstrahlung SPECT/CT were 4.78 ± 3.51 and 2.73 ± 1.18, respectively. The mean planning administered activity of 90Y-microspheres based on 99mTc-MAA SPECT/CT was 1.56 ± 0.80 GBq, while the implanted administered activity was 2.53 ± 1.23 GBq (p value < 0.001). The mean absorbed doses in the tumoral-liver estimated from 99mTc-MAA and 90Y-bremsstrahlung SPECT/CT were 127.44 ± 4.36 Gy and 135.98 ± 6.30 Gy, respectively. The corresponding mean absorbed doses in the non-tumoral liver were 34.61 ± 13.93 Gy and 55.04 ± 16.36 Gy. CONCLUSION This study provides evidence that the administered activity of 90Y-microspheres, as estimated from 90Y-bremsstrahlung SPECT/CT, was significantly higher than that estimated from 99mTc-MAA SPECT/CT resulted in increased absorbed doses in both the tumoral-liver and non-tumoral liver. However, 99mTc-MAA SPECT/CT remains a valuable planning tool for predicting the distribution of 90Y-microspheres in liver cancer treatment.
Collapse
Affiliation(s)
- Nut Noipinit
- Medical Physics Program, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Division of Nuclear Medicine, Department of Radiology, King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Chanan Sukprakun
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Punnarai Siricharoen
- Department of Computer Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Kitiwat Khamwan
- Medical Physics Program, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
3
|
Pham TP, Presles B, Popoff R, Alberini JL, Vrigneaud JM. Pre-treatment dosimetry in 90Y-SIRT: Is it possible to optimise SPECT reconstruction parameters and calculation methods for accurate dosimetry? Phys Med 2023; 115:103145. [PMID: 37852020 DOI: 10.1016/j.ejmp.2023.103145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 06/03/2023] [Accepted: 09/21/2023] [Indexed: 10/20/2023] Open
Abstract
PURPOSE The aim of this study was (a) to optimise the99mTc-SPECT reconstruction parameters for the pre-treatment dosimetry of90Y-selective internal radiation therapy (SIRT) and (b) to compare the accuracy of clinical dosimetry methods with full Monte-Carlo dosimetry (fMCD) performed with Gate. METHODS To optimise the reconstruction parameters, two hundred reconstructions with different parameters were performed on a NEMA phantom, varying the number of iterations, subsets, and post-filtering. The accuracy of the dosimetric methods was then investigated using an anthropomorphic phantom. Absorbed dose maps were generated using (1) the Partition Model (PM), (2) the Dose Voxel Kernel (DVK) convolution, and (3) the Local Deposition Method (LDM) with known activity restricted to the whole phantom (WP) or to the liver and lungs (LL). The dose to the lungs was calculated using the "multiple DVK" and "multiple LDM" methods. RESULTS Optimal OSEM reconstruction parameters were found to depend on object size and dosimetric criterion chosen (Dmean or DVH-derived metric). The Dmean of all three dosimetric methods was close (≤ 10%) to the Dmean of fMCD simulations when considering large segmented volumes (whole liver, normal liver). In contrast, the Dmean to the small volume (∅=31) was systemically underestimated (12%-25%). For lungs, the "multiple DVK" and "multiple LDM" methods yielded a Dmean within 20% for the WP method and within 10% for the LL method. CONCLUSIONS All three methods showed a substantial degradation of the dose-volume histograms (DVHs) compared to fMCD simulations. The DVK and LDM methods performed almost equally well, with the "multiple DVK" method being more accurate in the lungs.
Collapse
Affiliation(s)
- Tien-Phong Pham
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| | - Benoit Presles
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France
| | - Romain Popoff
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Louis Alberini
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Marc Vrigneaud
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| |
Collapse
|
4
|
Tabotta F, Gnesin S, Dunet V, Ponti A, Digklia A, Boughdad S, Schaefer N, Prior JO, Villard N, Tsoumakidou G, Denys A, Duran R. 99mTc-macroaggregated albumin SPECT/CT predictive dosimetry and dose-response relationship in uveal melanoma liver metastases treated with first-line selective internal radiation therapy. Sci Rep 2023; 13:13118. [PMID: 37573346 PMCID: PMC10423257 DOI: 10.1038/s41598-023-39994-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 08/03/2023] [Indexed: 08/14/2023] Open
Abstract
First-line selective internal radiation therapy (SIRT) showed promising outcomes in patients with uveal melanoma liver metastases (UMLM). Patient survival depends on liver's disease control. SIRT planning is essential and little is known about dosimetry. We investigated whether 99mTc-MAA-SPECT/CT dosimetry could predict absorbed doses (AD) evaluated on 90Y-PET/CT and assess the dose-response relationship in UMLM patients treated with first-line SIRT. This IRB-approved, single-center, retrospective analysis (prospectively collected cohort) included 12 patients (median age 63y, range 43-82). Patients underwent MRI/CT, 18F-FDG-PET/CT before and 3-6 months post-SIRT, and 90Y-PET/CT immediately post-SIRT. Thirty-two target lesions were included. AD estimates in tumor and non-tumor liver were obtained from 99mTc-MAA-SPECT/CT and post-SIRT 90Y-PET/CT, and assessed with Lin's concordance correlation coefficients (ρc and Cb), Pearson's coefficient correlation (ρ), and Bland-Altman analyses (mean difference ± standard deviation; 95% limits-of-agreement (LOA)). Influence of tumor characteristics and microsphere type on AD was analyzed. Tumor response was assessed according to size-based, enhancement-based and metabolic response criteria. Mean target lesion AD was 349 Gy (range 46-1586 Gy). Concordance between 99mTc-MAA-SPECT/CT and 90Y-PET/CT tumor dosimetry improved upon dose correction for the recovery coefficient (RC) (ρ = 0.725, ρc = 0.703, Cb = 0.969) with good agreement (mean difference: - 4.93 ± 218.3 Gy, 95%LOA: - 432.8-422.9). Without RC correction, concordance was better for resin microspheres (ρ = 0.85, ρc = 0.998, Cb = 0.849) and agreement was very good between predictive 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (mean difference: - 4.05 ± 55.9 Gy; 95%LOA: - 113.7-105.6). After RC correction, 99mTc-MAA-SPECT/CT dosimetry overestimated AD (- 70.9 ± 158.9 Gy; 95%LOA: - 382.3-240.6). For glass microspheres, concordance markedly improved with RC correction (ρ = 0.790, ρc = 0.713, Cb = 0.903 vs without correction: ρ = 0.395, ρc = 0.244, Cb = 0.617) and 99mTc-MAA-SPECT/CT dosimetry underestimated AD (148.9 ± 267.5 Gy; 95%LOA: - 375.4-673.2). For non-tumor liver, concordance was good between 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (ρ = 0.942, ρc = 0.852, Cb = 0.904). 99mTc-MAA-SPECT/CT slightly overestimated liver AD for resin (3.4 ± 3.4 Gy) and glass (11.5 ± 13.9 Gy) microspheres. Tumor AD was not correlated with baseline or post-SIRT lesion characteristics and no dose-response threshold could be identified. 99mTc-MAA-SPECT/CT dosimetry provides good estimates of AD to tumor and non-tumor liver in UMLM patients treated with first-line SIRT.
Collapse
Affiliation(s)
- Flavian Tabotta
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Silvano Gnesin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alexandre Ponti
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Antonia Digklia
- Department of Medical Oncology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Sarah Boughdad
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Niklaus Schaefer
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - John O Prior
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Nicolas Villard
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Georgia Tsoumakidou
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alban Denys
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Rafael Duran
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| |
Collapse
|
5
|
Pistone D, Amato E, Auditore L, Baldari S, Italiano A. Updating 90Y Voxel S-Values including internal Bremsstrahlung: Monte Carlo study and development of an analytical model. Phys Med 2023; 112:102624. [PMID: 37354805 DOI: 10.1016/j.ejmp.2023.102624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 06/09/2023] [Accepted: 06/11/2023] [Indexed: 06/26/2023] Open
Abstract
PURPOSE Internal Bremsstrahlung (IB) is a process accompanying β-decay but neglected in Voxel S-Values (VSVs) calculation. Aims of this work were to calculate, through Monte Carlo (MC) simulation, updated 90Y-VSVs including IB, and to develop an analytical model to evaluate 90Y-VSVs for any voxel size of practical interest. METHODS GATE (Geant4 Application for Tomographic Emission) was employed for simulating voxelized geometries of soft tissue, with voxels sides l ranging from 2 to 6 mm, in steps of 0.5 mm. The central voxel was set as a homogeneous source of 90Y when IB photons are not modelled. For each l, the VSVs were computed for 90Y decays alone and for 90Y + IB. The analytical model was then built through fitting procedures of the VSVs including IB contribution. RESULTS Comparing GATE-VSVs with and without IB, differences between + 25% and + 30% were found for distances from the central voxel larger than the maximum β-range. The analytical model showed an agreement with MC simulations within ± 5% in the central voxel and in the Bremsstrahlung tails, for any l value examined, and relative differences lower than ± 40%, for other distances from the source. CONCLUSIONS The presented 90Y-VSVs include for the first time the contribution due to IB, thus providing a more accurate set of dosimetric factors for three-dimensional internal dosimetry of 90Y-labelled radiopharmaceuticals and medical devices. Furthermore, the analytical model constitutes an easy and fast alternative approach for 90Y-VSVs estimation for non-standard voxel dimensions.
Collapse
Affiliation(s)
- Daniele Pistone
- Department of Biomedical and Dental Sciences and of Morphologic and Functional Imaging (BIOMORF), University of Messina, Messina, Italy; INFN, National Institute for Nuclear Physics, Section of Catania, Catania, Italy
| | - Ernesto Amato
- Department of Biomedical and Dental Sciences and of Morphologic and Functional Imaging (BIOMORF), University of Messina, Messina, Italy; INFN, National Institute for Nuclear Physics, Section of Catania, Catania, Italy; Health Physics Unit, University Hospital "Gaetano Martino", Messina, Italy.
| | - Lucrezia Auditore
- Department of Biomedical and Dental Sciences and of Morphologic and Functional Imaging (BIOMORF), University of Messina, Messina, Italy; INFN, National Institute for Nuclear Physics, Section of Catania, Catania, Italy
| | - Sergio Baldari
- Department of Biomedical and Dental Sciences and of Morphologic and Functional Imaging (BIOMORF), University of Messina, Messina, Italy; Nuclear Medicine Unit, University Hospital "Gaetano Martino", Messina, Italy
| | - Antonio Italiano
- INFN, National Institute for Nuclear Physics, Section of Catania, Catania, Italy; Department of Mathematical and Computational Sciences, Physics Sciences and Earth Sciences (MIFT), University of Messina, Messina, Italy
| |
Collapse
|
6
|
Doppler M, Reincke M, Bettinger D, Vogt K, Weiss J, Schultheiss M, Uller W, Verloh N, Goetz C. Predictive Value of [ 99mTc]-MAA-Based Dosimetry in Hepatocellular Carcinoma Patients Treated with [ 90Y]-TARE: A Single-Center Experience. Diagnostics (Basel) 2023; 13:2432. [PMID: 37510175 PMCID: PMC10378141 DOI: 10.3390/diagnostics13142432] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/13/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023] Open
Abstract
Transarterial radioembolization is a well-established method for the treatment of hepatocellular carcinoma. The tolerability and incidence of hepatic decompensation are related to the doses delivered to the tumor and healthy liver. This retrospective study was performed at our center to evaluate whether tumor- and healthy-liver-absorbed dose levels in TARE are predictive of tumor response according to the mRECIST 1.1 criteria and overall survival. One hundred and six patients with hepatocellular carcinoma were treated with [90Y]-loaded resin microspheres and completed the follow-up. The dose delivered to each compartment was calculated using a compartmental model. The model was based on [99mTc]-labelled albumin aggregate images obtained before the start of therapy. Tumor response was assessed after three months of treatment. Kaplan-Meier analysis was used to assess survival. The mean age of our population was 66 ± 13 years with a majority being BCLC B tumors. Forty-two patients presented with portal vein thrombosis. The response rate was 57% in the overall population and 59% in patients with thrombosis. Target-to-background (TBR) values measured on initial [99mTc]MAA-SPECT-imaging and tumor model dosimetric values were associated with tumor response (p < 0.001 and p = 0.009, respectively). A dosimetric threshold of 136.5 Gy was predictive of tumor response with a sensitivity of 84.2% and specificity of 89.4%. Overall survival was 24.1 months [IQR 13.1-36.4] for patients who responded to treatment compared to 10.4 months [IQR 6.3-15.9] for the remaining patients (p = 0.022). In this cohort, the initial [99mTc]MAA imaging is predictive of response and survival. The dosimetry prior to the application of TARE can be used for treatment planning and our results also suggest that the therapy is well-tolerated. In particular, hepatic decompensation can be predicted even in the presence of PVT.
Collapse
Affiliation(s)
- Michael Doppler
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Marlene Reincke
- Department of Medicine II, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Dominik Bettinger
- Department of Medicine II, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Katharina Vogt
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Jakob Weiss
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Michael Schultheiss
- Department of Medicine II, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
- Berta-Ottenstein-Programme, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Wibke Uller
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Niklas Verloh
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| | - Christian Goetz
- Department of Nuclear Medicine, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany
| |
Collapse
|
7
|
Patel MV, McNiel D, Brunson C, Kuo PH, Hennemeyer CT, Woodhead G, McGregor H. Prior ablation and progression of disease correlate with higher tumor-to-normal liver 99mTc-MAA uptake ratio in hepatocellular carcinoma. Abdom Radiol (NY) 2023; 48:752-757. [PMID: 36344658 DOI: 10.1007/s00261-022-03718-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE Factors affecting tumor-to-normal tissue ratio (T:N) have implications for patient selection, dosimetry, and outcomes when considering radioembolization for HCC. This study sought to evaluate patient, disease specific, and technical parameters that predict T:N as measured on planning pre-90Y radioembolization 99mTc-MAA scintigraphy for hepatocellular carcinoma (HCC). METHODS 99mTc-MAA hepatic angiography procedures with SPECT/CT over a 4-year period were reviewed. Data recorded included patient demographics, details of underlying liver disease, tumor size, history of prior treatments for HCC and technical parameters from angiography. Anatomic-based segmentation was performed in 93 cases for measurement of tumor and perfused liver volumes and SPECT counts. T:N were calculated and correlated with collected variables. RESULTS Mean calculated T:N was 2.52. History of prior ablation was significantly correlated with higher T:N (mean 3.39 vs 2.24, p = 0.003). Cases in which mapping was being performed for treatment of disease progression was significantly correlated with higher T:N (mean 3.35 vs 2.14, p = 0.001). Larger tumor size trended toward lower T:N (p = 0.052). CONCLUSION Patients with history of ablation and those undergoing treatment for disease progression have higher T:N and, therefore, could be considered for radioembolization preferentially over alternative treatments.
Collapse
Affiliation(s)
- Mikin V Patel
- Department of Radiology, University of Chicago Medical Center, 5841 S Maryland Ave, MC 2026, Chicago, IL, 60637, USA.
| | - David McNiel
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Christopher Brunson
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Phillip H Kuo
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Charles T Hennemeyer
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Gregory Woodhead
- Department of Medical Imaging, University of Arizona Medical Center, Tucson, AZ, USA
| | - Hugh McGregor
- Department of Radiology, University of Washington Medicine, Seattle, WA, USA
| |
Collapse
|
8
|
A Theranostic Approach in SIRT: Value of Pre-Therapy Imaging in Treatment Planning. J Clin Med 2022; 11:jcm11237245. [PMID: 36498819 PMCID: PMC9736029 DOI: 10.3390/jcm11237245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 11/24/2022] [Accepted: 12/02/2022] [Indexed: 12/12/2022] Open
Abstract
Selective internal radiation therapy (SIRT) is one of the treatment options for liver tumors. Microspheres labelled with a therapeutic radionuclide (90Y or 166Ho) are injected into the liver artery feeding the tumor(s), usually achieving a high tumor absorbed dose and a high tumor control rate. This treatment adopts a theranostic approach with a mandatory simulation phase, using a surrogate to radioactive microspheres (99mTc-macroaggregated albumin, MAA) or a scout dose of 166Ho microspheres, imaged by SPECT/CT. This pre-therapy imaging aims to evaluate the tumor targeting and detect potential contraindications to SIRT, i.e., digestive extrahepatic uptake or excessive lung shunt. Moreover, the absorbed doses to the tumor(s) and the healthy liver can be estimated and used for planning the therapeutic activity for SIRT optimization. The aim of this review is to evaluate the accuracy of this theranostic approach using pre-therapy imaging for simulating the biodistribution of the microspheres. This review synthesizes the recent publications demonstrating the advantages and limitations of pre-therapy imaging in SIRT, particularly for activity planning.
Collapse
|
9
|
Jokar N, Moradhaseli F, Ahmadzadehfar H, Jafari E, Nikeghbalian S, Rasekhi AR, Assadi M. Theranostic approach in liver cancer: an emerging paradigm to optimize personalized medicine. Clin Transl Imaging 2022. [DOI: 10.1007/s40336-022-00525-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
10
|
Trans-arterial Radioembolization Dosimetry in 2022. Cardiovasc Intervent Radiol 2022; 45:1608-1621. [PMID: 35982334 DOI: 10.1007/s00270-022-03215-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 06/26/2022] [Indexed: 11/02/2022]
Abstract
Trans-arterial radioembolization is currently performed using 90Y-loaded glass or resin microspheres and also using 166Ho-loaded microspheres. The goal of this review is to present dosimetry and radiobiology concepts, the different dosimetry approaches available (simulation-based dosimetry and post-treatment dosimetry), main confounding factors as main clinical dosimetry results provided during the last decade for both hepatocellular carcinoma (HCC) and metastases of colorectal carcinoma (mCRC). Based on the different number of microspheres or different isotope used, radiobiology of the three devices is different, meaning that tumouricidal doses and maximal tolerated doses are different. Tumouricidal doses described for HCCs were 100-120 grays (Gy) with 90Y resin microspheres and 205 Gy with 90Y glass microspheres. For mCRC, it is 39-60 with 90Y resin microspheres, 139 Gy with 90Y glass microspheres and 90 Gy with 166Ho microspheres. An impact of tumoural doses with overall survival has also been reported. Personalised dosimetry has been developed and is now recommended by several international expert groups. Level-one evidence of the major impact of personalised dosimetry on response and overall survival in HCC is now available, bringing a new standard approach for TARE in clinical practice as well as for trial design.
Collapse
|
11
|
Gulec SA, McGoron AJ. Radiomicrosphere Dosimetry: Principles and Current State of the Art. Semin Nucl Med 2022; 52:215-228. [DOI: 10.1053/j.semnuclmed.2021.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
12
|
Filippi L, Braat AJ. Theragnostics in primary and secondary liver tumors: the need for a personalized approach. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:353-370. [PMID: 34881847 DOI: 10.23736/s1824-4785.21.03407-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Primary and secondary hepatic tumors have a dramatic impact in oncology. Despite many advances in diagnosis and therapy, the management of hepatic malignancies is still challenging, ranging from various loco-regional approaches to system therapies. In this scenario, theragnostic approaches, based on the administration of a radiopharmaceuticals' pair, the first labeled with a radionuclide suitable for the diagnostic phase and the second one bound to radionuclide emitting particles for therapy, is gaining more and more importance. Selective internal radiation therapy (SIRT) with microspheres labeled with 90Y or 166Ho is widely used as a loco-regional treatment for primary and secondary hepatic tumors. While 166Ho presents both gamma and beta emission and can be therefore considered a real "theragnostic" agent, for 90Y-microspheres theragnostic approach is realized at the diagnostic phase through the utilization of macroaggregates of human albumin, labeled with 99mTc as "biosimilar" agent respect to microspheres. The aim of the present review was to cover theragnostic applications of 90Y/166Ho-labeled microspheres in clinical practice. Furthermore, we report the preliminary data concerning the potential role of some emerging theragnostic biomarkers for hepatocellular carcinoma, such as glypican-3 (GPC3) and prostate specific membrane antigen (PSMA).
Collapse
Affiliation(s)
- Luca Filippi
- Department of Nuclear Medicine, Santa Maria Goretti Hospital, Latina, Italy -
| | - Arthur J Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
13
|
Pandit-Taskar N, Iravani A, Lee D, Jacene H, Pryma D, Hope T, Saboury B, Capala J, Wahl RL. Dosimetry in Clinical Radiopharmaceutical Therapy of Cancer: Practicality Versus Perfection in Current Practice. J Nucl Med 2021; 62:60S-72S. [PMID: 34857623 DOI: 10.2967/jnumed.121.262977] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 10/22/2021] [Indexed: 12/25/2022] Open
Abstract
The use of radiopharmaceutical therapies (RPTs) in the treatment of cancers is growing rapidly, with more agents becoming available for clinical use in last few years and many new RPTs being in development. Dosimetry assessment is critical for personalized RPT, insofar as administered activity should be assessed and optimized in order to maximize tumor-absorbed dose while keeping normal organs within defined safe dosages. However, many current clinical RPTs do not require patient-specific dosimetry based on current Food and Drug Administration-labeled approvals, and overall, dosimetry for RPT in clinical practice and trials is highly varied and underutilized. Several factors impede rigorous use of dosimetry, as compared with the more convenient and less resource-intensive practice of empiric dosing. We review various approaches to applying dosimetry for the assessment of activity in RPT and key clinical trials, the extent of dosimetry use, the relative pros and cons of dosimetry-based versus fixed activity, and practical limiting factors pertaining to current clinical practice.
Collapse
Affiliation(s)
| | - Amir Iravani
- Washington University School of Medicine, St. Louis, Missouri
| | - Dan Lee
- Ochsner Medical Center, New Orleans, Louisiana
| | | | - Dan Pryma
- Penn Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Thomas Hope
- University of San Francisco, San Francisco, California; and
| | | | - Jacek Capala
- National Institutes of Health, Bethesda, Maryland
| | - Richard L Wahl
- Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
14
|
Chiesa C, Sjogreen-Gleisner K, Walrand S, Strigari L, Flux G, Gear J, Stokke C, Gabina PM, Bernhardt P, Konijnenberg M. EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres. EJNMMI Phys 2021; 8:77. [PMID: 34767102 PMCID: PMC8589932 DOI: 10.1186/s40658-021-00394-3] [Citation(s) in RCA: 59] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 06/21/2021] [Indexed: 11/27/2022] Open
Abstract
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
Collapse
Affiliation(s)
- Carlo Chiesa
- Nuclear Medicine Unit, Foundation IRCCS Istituto Nazionale Tumori, Milan, Italy
| | | | - Stephan Walrand
- Nuclear Medicine, Molecular Imaging, Radiotherapy and Oncology Unit (MIRO), IECR, Université Catholique de Louvain, Brussels, Belgium
| | - Lidia Strigari
- Medical Physics Division, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Glenn Flux
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Jonathan Gear
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Caroline Stokke
- Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway
| | - Pablo Minguez Gabina
- Department of Medical Physics and Radiation Protection, Gurutzeta/Cruces University Hospital, Barakaldo, Spain
| | - Peter Bernhardt
- Department of Radiation Physics, Institute of Clinical Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mark Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
15
|
Plachouris D, Tzolas I, Gatos I, Papadimitroulas P, Spyridonidis T, Apostolopoulos D, Papathanasiou N, Visvikis D, Plachouri KM, Hazle JD, Kagadis GC. A deep-learning-based prediction model for the biodistribution of 90 Y microspheres in liver radioembolization. Med Phys 2021; 48:7427-7438. [PMID: 34628667 DOI: 10.1002/mp.15270] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Radioembolization with 90 Y microspheres is a treatment approach for liver cancer. Currently, employed dosimetric calculations exhibit low accuracy, lacking consideration of individual patient, and tissue characteristics. PURPOSE The purpose of the present study was to employ deep learning (DL) algorithms to differentiate patterns of pretreatment distribution of 99m Tc-macroaggregated albumin on SPECT/CT and post-treatment distribution of 90 Y microspheres on PET/CT and to accurately predict how the 90 Y-microspheres will be distributed in the liver tissue by radioembolization therapy. METHODS Data for 19 patients with liver cancer (10 with hepatocellular carcinoma, 5 with intrahepatic cholangiocarcinoma, 4 with liver metastases) who underwent radioembolization with 90 Y microspheres were used for the DL training. We developed a 3D voxel-based variation of the Pix2Pix model, which is a special type of conditional GANs designed to perform image-to-image translation. SPECT and CT scans along with the clinical target volume for each patient were used as inputs, as were their corresponding post-treatment PET scans. The real and predicted absorbed PET doses for the tumor and the whole liver area were compared. Our model was evaluated using the leave-one-out method, and the dose calculations were measured using a tissue-specific dose voxel kernel. RESULTS The comparison of the real and predicted PET/CT scans showed an average absorbed dose difference of 5.42% ± 19.31% and 0.44% ± 1.64% for the tumor and the liver area, respectively. The average absorbed dose differences were 7.98 ± 31.39 Gy and 0.03 ± 0.25 Gy for the tumor and the non-tumor liver parenchyma, respectively. Our model had a general tendency to underpredict the dosimetric results; the largest differences were noticed in one case, where the model underestimated the dose to the tumor area by 56.75% or 72.82 Gy. CONCLUSIONS The proposed deep-learning-based pretreatment planning method for liver radioembolization accurately predicted 90 Y microsphere biodistribution. Its combination with a rapid and accurate 3D dosimetry method will render it clinically suitable and could improve patient-specific pretreatment planning.
Collapse
Affiliation(s)
- Dimitris Plachouris
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Ioannis Tzolas
- School of Electrical and Computer Engineering, University of Patras, Rion, Greece
| | - Ilias Gatos
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Panagiotis Papadimitroulas
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,R&D Department, Bioemission Technology Solutions, Athens, Greece
| | - Trifon Spyridonidis
- Department of Nuclear Medicine, School of Medicine, University of Patras, Rion, Greece
| | | | | | | | | | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - George C Kagadis
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
16
|
Accurate non-tumoral 99mTc-MAA absorbed dose prediction to plan optimized activities in liver radioembolization using resin microspheres. Phys Med 2021; 89:250-257. [PMID: 34438353 DOI: 10.1016/j.ejmp.2021.07.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 07/23/2021] [Accepted: 07/28/2021] [Indexed: 12/19/2022] Open
Abstract
AIM The manufacturers' recommended methods to calculate delivered activities in liver radioembolization are simplistic and only slightly personalized. Activity planning could also be based on a 99mTc-macroaggregated albumin SPECT/CT (MAA) using the partition model but its accuracy is controversial. This study evaluates the dose parameters in the normal liver and in the tumor compartments using MAA SPECT/CT (pre-therapeutic imaging) and 90Y TOF-PET/CT (post-therapy imaging). Finally, we propose a prescription of the activity as a function of the normal liver MAA distribution. METHOD 66 procedures of RE (with resin microspheres) corresponding to 171 lesions were analyzed. Tumor to normal targeted liver uptake (T/NTL), tumor absorbed dose (TD) and whole normal liver absorbed (WNLD) were assessed with MAA and 90Y imaging. Secondly, activities were recalculated using the MAA distribution in the normal liver compartment to reach the maximal tolerable liver dose. These Activities were compared to activities defined with the BSA method. RESULTS Compared to 90Y imaging, our study demonstrated an accurate estimation of the WNLD using MAA imaging (Pearson's R = 0.97, p < 0.001). On the contrary, significant variations were found for TD (R = 0.65, p < 0.001). The MAA T/NTL ratio has a 85% positive predictive value in identifying patients who will get a 90Y T/NTL ratio above 1.5. Moreover, activities calculated using the MAA distribution in the normal liver compartment were significantly higher to activities defined with the BSA method. CONCLUSION Whole normal liver absorbed doses are accurately predicted with MAA imaging and could be used to optimize the activity planning.
Collapse
|
17
|
Vallati GE, Trobiani C, Teodoli L, Lai Q, Cappelli F, Ungania S, Catalano C, Lucatelli P. Sarcopenia Worsening One Month after Transarterial Radioembolization Predicts Progressive Disease in Patients with Advanced Hepatocellular Carcinoma. BIOLOGY 2021; 10:biology10080728. [PMID: 34439960 PMCID: PMC8389627 DOI: 10.3390/biology10080728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 07/15/2021] [Accepted: 07/27/2021] [Indexed: 11/30/2022]
Abstract
Simple Summary Sarcopenia measured at one-month CT follow up after TARE (transarterial radioembolization) treatment is a predictive factor for the best tumor response in patients with locally advanced HCC. Abstract (1) Background: To demonstrate correlation between skeletal muscle depletion measured before and after one month of TARE treatment and its induced local response rate. (2) Material and methods: For this retrospective, single center study, we evaluated 86 patients with HCC treated with TARE. Sarcopenia status was measured using the psoas muscle index (PMI). The PMI was calculated according to the formula: PMI [mm/m2]: [(minor diameter of left psoas + major diameter of left psoas + minor diameter of right psoas + major diameter of right psoas)/4]/height in m2. Population was divided in two groups according to the delta value of PMI measured at the time of TARE and one month after TARE, a group in which the delta PMI was stable or increased (No-Sarcopenia group; n = 42) vs. a group in which the delta-PMI decreased (Sarcopenia group; n = 44). Patient response was evaluated at 1, 3 and 6 months after TARE treatment with CT/MRI. (3) Results: When the radiological response of the tumor was evaluated according to the mRECIST criteria, the two groups were similar in terms of rates of complete response (p = 0.42), partial response (p = 0.26) and stable disease (p = 0.59). Progressive disease (PD) was more commonly observed in the Sarcopenia group (38.6% vs. 11.9%; p = 0.006). (4) Conclusions: Worsening of sarcopenia status measured one month after TARE is able to predict patients who will undergo disease progression.
Collapse
Affiliation(s)
- Giulio Eugenio Vallati
- Interventional Radiology Unit of “IRCCS Istituto Nazionale Tumori Regina Elena”, 00138 Rome, Italy; (G.E.V.); (F.C.)
| | - Claudio Trobiani
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Policlinico Umberto I, University of Rome “Sapienza”, 00161 Rome, Italy; (L.T.); (C.C.); (P.L.)
- Correspondence:
| | - Leonardo Teodoli
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Policlinico Umberto I, University of Rome “Sapienza”, 00161 Rome, Italy; (L.T.); (C.C.); (P.L.)
| | - Quirino Lai
- Department of General Surgery and Organ Transplantation, Sapienza University of Rome, 00161 Rome, Italy;
| | - Federico Cappelli
- Interventional Radiology Unit of “IRCCS Istituto Nazionale Tumori Regina Elena”, 00138 Rome, Italy; (G.E.V.); (F.C.)
| | - Sara Ungania
- Physics Department of “Istituto Regina Elena, Istituto di Ricovero e Cura a Carattere Scientifico”, 00138 Rome, Italy;
| | - Carlo Catalano
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Policlinico Umberto I, University of Rome “Sapienza”, 00161 Rome, Italy; (L.T.); (C.C.); (P.L.)
| | - Pierleone Lucatelli
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Policlinico Umberto I, University of Rome “Sapienza”, 00161 Rome, Italy; (L.T.); (C.C.); (P.L.)
| |
Collapse
|
18
|
Labour J, Boissard P, Baudier T, Khayi F, Kryza D, Durebex PV, Martino SPD, Mognetti T, Sarrut D, Badel JN. Yttrium-90 quantitative phantom study using digital photon counting PET. EJNMMI Phys 2021; 8:56. [PMID: 34318383 PMCID: PMC8316557 DOI: 10.1186/s40658-021-00402-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 06/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.
Collapse
Affiliation(s)
- Joey Labour
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | | | - Thomas Baudier
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Fouzi Khayi
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - David Kryza
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
- Hospices Civils de Lyon; Université de Lyon; Université Claude Bernard Lyon 1; LAGEPP UMR 5007 CNRS, Lyon, France
| | | | | | | | - David Sarrut
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Jean-Noël Badel
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| |
Collapse
|
19
|
166Ho microsphere scout dose for more accurate radioembolization treatment planning. Eur J Nucl Med Mol Imaging 2021; 47:744-747. [PMID: 31875243 DOI: 10.1007/s00259-019-04617-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
20
|
Rodríguez-Fraile M, Ezponda A, Grisanti F, Morán V, Calvo M, Berián P, de la Cuesta AM, Sancho L, Iñarrairaegui M, Sangro B, Bilbao JI. The joint use of 99mTc-MAA-SPECT/CT and cone-beam CT optimizes radioembolization planning. EJNMMI Res 2021; 11:23. [PMID: 33661428 PMCID: PMC7933314 DOI: 10.1186/s13550-021-00764-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 02/18/2021] [Indexed: 12/13/2022] Open
Abstract
Purpose To determine which imaging method used during radioembolization (RE) work-up: contrast-enhanced computed tomography (CECT), 99mTc-MAA-SPECT/CT or cone beam-CT (CBCT), more accurately predicts the final target volume (TgV) as well as the influence that each modality has in the dosimetric calculation. Methods TgVs from 99mTc-MAA-SPECT/CT, CECT and CBCT were consecutively obtained in 24 patients treated with RE and compared with 90Y PET/CT TgV. Using the TgVs estimated by each imaging modality and a fictitious activity of 1 GBq, the corresponding absorbed doses by tumor and non-tumoral parenchyma were calculated for each patient. The absorbed doses for each modality were compared with the ones obtained using 90Y PET/CT TgV. Results 99mTc-MAA-SPECT/CT predicted 90Y PET/CT TgV better than CBCT or CECT, even for selective or superselective administrations. Likewise, 99mTc-MAA-SPECT/CT showed dosimetric values more similar to those obtained with 90Y PET/CT. Nevertheless, CBCT provided essential information for RE planning, such as ensuring the total coverage of the tumor and, in cases with more than one feeding artery, splitting the activity according to the volume of tumor perfused by each artery. Conclusion The joint use of 99mTc-MAA-SPECT/CT and CBCT optimizes dosimetric planning for RE procedures, enabling a more accurate personalized approach.
Collapse
Affiliation(s)
| | - Ana Ezponda
- Radiology Department, Clínica Universidad de Navarra, Pamplona, Spain
| | - Fabiana Grisanti
- Nuclear Medicine Department, Clínica Universidad de Navarra, Pamplona, Spain
| | - Verónica Morán
- Medical Physics Department, Clínica Universidad de Navarra, Madrid, Spain
| | - Marta Calvo
- Radiology Department, Clínica Universidad de Navarra, Pamplona, Spain
| | - Pablo Berián
- Radiology Department, Clínica Universidad de Navarra, Pamplona, Spain
| | | | - Lidia Sancho
- Nuclear Medicine Department, Clínica Universidad de Navarra, Madrid, Spain
| | - Mercedes Iñarrairaegui
- Department of Internal Medicine-Hepatology, Clínica Universidad de Navarra, Pamplona, Spain
| | - Bruno Sangro
- Department of Internal Medicine-Hepatology, Clínica Universidad de Navarra, Pamplona, Spain
| | | |
Collapse
|
21
|
Levillain H, Burghelea M, Derijckere ID, Guiot T, Gulyban A, Vanderlinden B, Vouche M, Flamen P, Reynaert N. Combined quality and dose-volume histograms for assessing the predictive value of 99mTc-MAA SPECT/CT simulation for personalizing radioembolization treatment in liver metastatic colorectal cancer. EJNMMI Phys 2020; 7:75. [PMID: 33315160 PMCID: PMC7736450 DOI: 10.1186/s40658-020-00345-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 11/30/2020] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND The relationship between the mean absorbed dose delivered to the tumour and the outcome in liver metastases from colorectal cancer patients treated with radioembolization has already been presented in several studies. The optimization of the personalized therapeutic activity to be administered is still an open challenge. In this context, how well the 99mTc-MAA SPECT/CT predicts the absorbed dose delivered by radioembolization is essential. This work aimed to analyse the differences between predictive 99mTc-MAA-SPECT/CT and post-treatment 90Y-microsphere PET/CT dosimetry at different levels. Dose heterogeneity was compared voxel-to-voxel using the quality-volume histograms, subsequently used to demonstrate how it could be used to identify potential clinical parameters that are responsible for quantitative discrepancies between predictive and post-treatment dosimetry. RESULTS We analysed 130 lesions delineated in twenty-six patients. Dose-volume histograms were computed from predictive and post-treatment dosimetry for all volumes: individual lesion, whole tumoural liver (TL) and non-tumoural liver (NTL). For all dose-volume histograms, the following indices were extracted: D90, D70, D50, Dmean and D20. The results showed mostly no statistical differences between predictive and post-treatment dosimetries across all volumes and for all indices. Notably, the analysis showed no difference in terms of Dmean, confirming the results from previous studies. Quality factors representing the spread of the quality-volume histogram (QVH) curve around 0 (ideal QF = 0) were determined for lesions, TL and NTL. QVHs were classified into good (QF < 0.18), acceptable (0.18 ≤ QF < 0.3) and poor (QF ≥ 0.3) correspondence. For lesions and TL, dose- and quality-volume histograms are mostly concordant: 69% of lesions had a QF within good/acceptable categories (40% good) and 65% of TL had a QF within good/acceptable categories (23% good). For NTL, the results showed mixed results with 48% QF within the poor concordance category. Finally, it was demonstrated how QVH analysis could be used to define the parameters that predict the significant differences between predictive and post-treatment dose distributions. CONCLUSION It was shown that the use of the QVH is feasible in assessing the predictive value of 99mTc-MAA SPECT/CT dosimetry and in estimating the absorbed dose delivered to liver metastases from colorectal cancer via 90Y-microspheres. QVH analyses could be used in combination with DVH to enhance the predictive value of 99mTc-MAA SPECT/CT dosimetry and to assist personalized activity prescription.
Collapse
Affiliation(s)
- Hugo Levillain
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium.
- Nuclear Medicine Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, 1000, Brussels, Belgium.
| | - Manuela Burghelea
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium
| | - Ivan Duran Derijckere
- Nuclear Medicine Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, 1000, Brussels, Belgium
| | - Thomas Guiot
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium
| | - Akos Gulyban
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium
| | - Bruno Vanderlinden
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium
| | - Michael Vouche
- Department of Radiology, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, 1000, Brussels, Belgium
| | - Patrick Flamen
- Nuclear Medicine Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, 1000, Brussels, Belgium
| | - Nick Reynaert
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, 1 Rue Héger-Bordet, B-1000, Brussels, Belgium
| |
Collapse
|
22
|
Morán V, Prieto E, Sancho L, Rodríguez-Fraile M, Soria L, Zubiria A, Martí-Climent JM. Impact of the dosimetry approach on the resulting 90Y radioembolization planned absorbed doses based on 99mTc-MAA SPECT-CT: is there agreement between dosimetry methods? EJNMMI Phys 2020; 7:72. [PMID: 33284389 PMCID: PMC7721939 DOI: 10.1186/s40658-020-00343-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 11/24/2020] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Prior radioembolization, a simulation using 99mTc-macroaggregated albumin as 90Y-microspheres surrogate is performed. Gamma scintigraphy images (planar, SPECT, or SPECT-CT) are acquired to evaluate intrahepatic 90Y-microspheres distribution and detect possible extrahepatic and lung shunting. These images may be used for pre-treatment dosimetry evaluation to calculate the 90Y activity that would get an optimal tumor response while sparing healthy tissues. Several dosimetry methods are available, but there is still no consensus on the best methodology to calculate absorbed doses. The goal of this study was to retrospectively evaluate the impact of using different dosimetry approaches on the resulting 90Y-radioembolization pre-treatment absorbed dose evaluation based on 99mTc-MAA images. METHODS Absorbed doses within volumes of interest resulting from partition model (PM) and 3D voxel dosimetry methods (3D-VDM) (dose-point kernel convolution and local deposition method) were evaluated. Additionally, a new "Multi-tumor Partition Model" (MTPM) was developed. The differences among dosimetry approaches were evaluated in terms of mean absorbed dose and dose volume histograms within the volumes of interest. RESULTS Differences in mean absorbed dose among dosimetry methods are higher in tumor volumes than in non-tumoral ones. The differences between MTPM and both 3D-VDM were substantially lower than those observed between PM and any 3D-VDM. A poor correlation and concordance were found between PM and the other studied dosimetry approaches. DVH obtained from either 3D-VDM are pretty similar in both healthy liver and individual tumors. Although no relevant global differences, in terms of absorbed dose in Gy, between both 3D-VDM were found, important voxel-by-voxel differences have been observed. CONCLUSIONS Significant differences among the studied dosimetry approaches for 90Y-radioembolization treatments exist. Differences do not yield a substantial impact in treatment planning for healthy tissue but they do for tumoral liver. An individual segmentation and evaluation of the tumors is essential. In patients with multiple tumors, the application of PM is not optimal and the 3D-VDM or the new MTPM are suggested instead. If a 3D-VDM method is not available, MTPM is the best option. Furthermore, both 3D-VDM approaches may be indistinctly used.
Collapse
Affiliation(s)
- Verónica Morán
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Madrid, Spain
| | - Elena Prieto
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain.,IdisNA, Navarra Institute for Health Research, Pamplona, Spain
| | - Lidia Sancho
- Department of Nuclear Medicine, Clínica Universidad de Navarra, Madrid, Spain
| | - Macarena Rodríguez-Fraile
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain.,Department of Nuclear Medicine, Clínica Universidad de Navarra, Pamplona, Spain
| | - Leticia Soria
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Madrid, Spain
| | - Arantxa Zubiria
- Department of Radiation Oncology, Clínica Universidad de Navarra, Pamplona, Spain
| | - Josep M Martí-Climent
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain. .,IdisNA, Navarra Institute for Health Research, Pamplona, Spain.
| |
Collapse
|
23
|
Auditore L, Amato E, Boughdad S, Meyer M, Testart N, Cicone F, Beigelman-Aubry C, Prior JO, Schaefer N, Gnesin S. Monte Carlo 90Y PET/CT dosimetry of unexpected focal radiation-induced lung damage after hepatic radioembolisation. Phys Med Biol 2020; 65:235014. [PMID: 33245055 DOI: 10.1088/1361-6560/abbc80] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Transarterial radioembolization (TARE) with 90Y-loaded microspheres is an established therapeutic option for inoperable hepatic tumors. Increasing knowledge regarding TARE hepatic dose-response and dose-toxicity correlation is available but few studies have investigated dose-toxicity correlation in extra-hepatic tissues. We investigated absorbed dose levels for the appearance of focal lung damage in a case of off-target deposition of 90Y microspheres and compared them with the corresponding thresholds recommended to avoiding radiation induced lung injury following TARE. A 64-year-old male patient received 1.6 GBq of 90Y-labelled glass microspheres for an inoperable left lobe hepatocellular carcinoma. A focal off-target accumulation of radiolabeled microspheres was detected in the left lung upper lobe at the post-treatment 90Y-PET/CT, corresponding to a radiation-induced inflammatory lung lesion at the 3-months 18F-FDG PET/CT follow-up. 90Y-PET/CT data were used as input for Monte-Carlo based absorbed dose estimations. Dose-volume-histograms were computed to characterize the heterogeneity of absorbed dose distribution. The dose level associated with the appearance of lung tissue damage was estimated as the median absorbed dose measured at the edge of the inflammatory nodule. To account for respiratory movements and possible inaccuracy of image co-registration, three different methods were evaluated to define the irradiated off-target volume. Monte Carlo-derived absorbed dose distribution showed a highly heterogeneous absorbed dose pattern at the site of incidental microsphere deposition (volume = 2.13 ml) with a maximum dose of 630 Gy. Absorbed dose levels ranging from 119 Gy to 133 Gy, were estimated at the edge of the inflammatory nodule, depending on the procedure used to define the target volume. This report describes an original Monte Carlo based patient-specific dosimetry methodology for the study of the radiation-induced damage in a focal lung lesion after TARE. In our patient, radiation-induced focal lung damage occurred at significantly higher absorbed doses than those considered for single administration or cumulative lung dose delivered during TARE.
Collapse
Affiliation(s)
- Lucrezia Auditore
- Section of Radiological Sciences, Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Brosch J, Gosewisch A, Kaiser L, Seidensticker M, Ricke J, Zellmer J, Bartenstein P, Ziegler S, Ilhan H, Todica A, Böning G. 3D image-based dosimetry for Yttrium-90 radioembolization of hepatocellular carcinoma: Impact of imaging method on absorbed dose estimates. Phys Med 2020; 80:317-326. [PMID: 33248338 DOI: 10.1016/j.ejmp.2020.11.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 11/09/2020] [Accepted: 11/11/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND To improve therapy outcome of Yttrium-90 selective internal radiation therapy (90Y SIRT), patient-specific post-therapeutic dosimetry is required. For this purpose, various dosimetric approaches based on different available imaging data have been reported. The aim of this work was to compare post-therapeutic 3D absorbed dose images using Technetium-99m (99mTc) MAA SPECT/CT, Yttrium-90 (90Y) bremsstrahlung (BRS) SPECT/CT, and 90Y PET/CT. METHODS Ten SIRTs of nine patients with unresectable hepatocellular carcinoma (HCC) were investigated. The 99mTc SPECT/CT data, obtained from 99mTc-MAA-based treatment simulation prior to 90Y SIRT, were scaled with the administered 90Y therapy activity. 3D absorbed dose images were generated by dose kernel convolution with scaled 99mTc/90Y SPECT/CT, 90Y BRS SPECT/CT, and 90Y PET/CT data of each patient. Absorbed dose estimates in tumor and healthy liver tissue obtained using the two SPECT/CT methods were compared against 90Y PET/CT. RESULTS The percentage deviation of tumor absorbed dose estimates from 90Y PET/CT values was on average -2 ± 18% for scaled 99mTc/90Y SPECT/CT, whereas estimates from 90Y BRS SPECT/CT differed on average by -50 ± 13%. For healthy liver absorbed dose estimates, all three imaging methods revealed comparable values. CONCLUSION The quantification capabilities of the imaging data influence 90Y SIRT tumor dosimetry, while healthy liver absorbed dose values were comparable for all investigated imaging data. When no 90Y PET/CT image data are available, the proposed scaled 99mTc/90Y SPECT/CT dosimetry method was found to be more appropriate for HCC tumor dosimetry than 90Y BRS SPECT/CT based dosimetry.
Collapse
Affiliation(s)
- Julia Brosch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany.
| | - Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Lena Kaiser
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Jens Ricke
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Johannes Zellmer
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Sibylle Ziegler
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
25
|
Thomas MA, Mahvash A, Abdelsalam M, Kaseb AO, Kappadath SC. Planning dosimetry for 90 Y radioembolization with glass microspheres: Evaluating the fidelity of 99m Tc-MAA and partition model predictions. Med Phys 2020; 47:5333-5342. [PMID: 32790882 DOI: 10.1002/mp.14452] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 07/12/2020] [Accepted: 07/30/2020] [Indexed: 01/10/2023] Open
Abstract
PURPOSE 99m Tc-MAA-SPECT/CT may be used in 90 Y-glass microsphere radioembolization treatment planning to assess perfused liver volumes and absorbed dose distributions. The partition model (PM) offers a more detailed planning dosimetry option beyond the single-compartment model more traditionally used in 90 Y radioembolization. As 90 Y radioembolization treatments shift toward activities and doses that aim to achieve tumor control, accurate and reliable treatment planning dosimetry for both tumors and normal liver (NL) becomes more critical. In this work, we explore the accuracy and precision of 90 Y dosimetry predictions from pretherapy 99m Tc-MAA and PM. METHODS Both PM and voxel dosimetry models were used to calculate tumor and NL mean doses using both planning 99m Tc-MAA and verification 90 Y-SPECT/CT in this retrospective analysis of hepatocellular carcinoma cases treated with glass microspheres (NCT01900002, n = 32). Linear regression models were developed at first access, and then later correct, the estimates by (a) 99m Tc-MAA for 90 Y voxel dosimetry and (b) 99m Tc-MAA PM for voxel dosimetry, separately for both tumors and NL. Bland-Altman analysis was then used to evaluate the accuracy and precision of the regression model predictions with the mean bias and 95% prediction intervals (PI, ±1.96σ). Two categories of cases were stratified (catheter matched vs catheter unmatched) by establishing the level of 99m Tc-MAA and 90 Y catheter position alignment. Only catheter-matched cases were included in the 99m Tc-MAA vs 90 Y voxel dosimetry comparison, while all cases were used to compare dosimetry models (PM vs voxel). RESULTS Half (16/32) of cases were deemed catheter matched. 99m Tc-MAA could reliably predict NL doses in catheter-matched cases after application of the linear model, with mean bias (PI) of -1% (±31%). PM was equivalent to voxel dosimetry for NL doses with mean bias (PI) of 0% (±1%). Even among catheter-matched cases, 99m Tc-MAA planning for 90 Y tumor voxel doses was poor, overestimating dose by an average of nearly 40%. Upon application of the linear model, 99m Tc-MAA predictions for 90 Y tumor voxel dose were only minimally biased (-4%) but possessed very large PI (±104%). PM predictions for tumor voxel dose using the linear model also showed small bias (-6%) but maintained similarly high PI of ±90%. Cases with tumors representing a large majority (>80%) of the total tumor volume demonstrated the best scenarios for 99m Tc-MAA and PM tumor dose predictions, with mean biases (PI) of -3% (±53%) and -4% (±21%), respectively. CONCLUSION The unconditional use of 99m Tc-MAA to predict 90 Y dosimetry across all cases is not recommended due to: (a) demonstrated the risk of unmatched catheter positions between procedures, and (b) large bias and uncertainty in 99m Tc-MAA predictions in cases with matched catheter locations. However, NL voxel dose predictions with 99m Tc-MAA are clinically viable and either PM or voxel dosimetry can be used to produce equivalent predictions. Both 99m Tc-MAA and PM can provide tumor dose predictions with potential clinical utility, but only in catheter-matched cases and with tumors comprising a clear majority (>80%) of the total tumor volume. These findings stratify the predictive fidelity of 99m Tc-MAA- and PM-based treatment planning for 90 Y dosimetry in improving treatment outcomes.
Collapse
Affiliation(s)
- M Allan Thomas
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Mohamed Abdelsalam
- Department of Interventional Radiology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Ahmed O Kaseb
- Department of GI Medical Oncology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - S Cheenu Kappadath
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| |
Collapse
|
26
|
Jafargholi Rangraz E, Tang X, Van Laeken C, Maleux G, Dekervel J, Van Cutsem E, Verslype C, Baete K, Nuyts J, Deroose CM. Quantitative comparison of pre-treatment predictive and post-treatment measured dosimetry for selective internal radiation therapy using cone-beam CT for tumor and liver perfusion territory definition. EJNMMI Res 2020; 10:94. [PMID: 32797332 PMCID: PMC7427681 DOI: 10.1186/s13550-020-00675-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 07/17/2020] [Indexed: 11/21/2022] Open
Abstract
Background Selective internal radiation therapy (SIRT) is a promising treatment for unresectable hepatic malignancies. Predictive dose calculation based on a simulation using 99mTc-labeled macro-aggregated albumin (99mTc-MAA) before the treatment is considered as a potential tool for patient-specific treatment planning. Post-treatment dose measurement is mainly performed to confirm the planned absorbed dose to the tumor and non-tumor liver volumes. This study compared the predicted and measured absorbed dose distributions. Methods Thirty-one patients (67 tumors) treated by SIRT with resin microspheres were analyzed. Predicted and delivered absorbed dose was calculated using 99mTc-MAA-SPECT and 90Y-TOF-PET imaging. The voxel-level dose distribution was derived using the local deposition model. Liver perfusion territories and tumors have been delineated on contrast-enhanced CBCT images, which have been acquired during the 99mTc-MAA work-up. Several dose-volume histogram (DVH) parameters together with the mean dose for liver perfusion territories and non-tumoral and tumoral compartments were evaluated. Results A strong correlation between the predicted and measured mean dose for non-tumoral volume was observed (r = 0.937). The ratio of measured and predicted mean dose to this volume has a first, second, and third interquartile range of 0.83, 1.05, and 1.25. The difference between the measured and predicted mean dose did not exceed 11 Gy. The correlation between predicted and measured mean dose to the tumor was moderate (r = 0.623) with a mean difference of − 9.3 Gy. The ratio of measured and predicted tumor mean dose had a median of 1.01 with the first and third interquartile ranges of 0.58 and 1.59, respectively. Our results suggest that 99mTc-MAA-based dosimetry could predict under or over dosing of the non-tumoral liver parenchyma for almost all cases. For more than two thirds of the tumors, a predictive absorbed dose correctly indicated either good tumor dose coverage or under-dosing of the tumor. Conclusion Our results highlight the predictive value of 99mTc-MAA-based dose estimation to predict non-tumor liver irradiation, which can be applied to prescribe an optimized activity aiming at avoiding liver toxicity. Compared to non-tumoral tissue, a poorer agreement between predicted and measured absorbed dose is observed for tumors.
Collapse
Affiliation(s)
- Esmaeel Jafargholi Rangraz
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium.
| | - Xikai Tang
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | | | - Geert Maleux
- Radiology Section, University Hospitals Leuven, Department of Imaging and Pathology, Leuven, Belgium
| | - Jeroen Dekervel
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Eric Van Cutsem
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Chris Verslype
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Kristof Baete
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | - Johan Nuyts
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | - Christophe M Deroose
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| |
Collapse
|
27
|
Personalised Dosimetry in Radioembolisation for HCC: Impact on Clinical Outcome and on Trial Design. Cancers (Basel) 2020; 12:cancers12061557. [PMID: 32545572 PMCID: PMC7353030 DOI: 10.3390/cancers12061557] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/03/2020] [Accepted: 06/05/2020] [Indexed: 12/21/2022] Open
Abstract
Selective internal radiation therapy (SIRT) of hepatocellular carcinoma (HCC) has been used for many years, usually without any specific dosimetry endpoint. Despite good clinical results in early phase studies or in cohort studies, three randomized trials in locally advanced HCC available failed to demonstrate any improvement of overall overall survival (OS) in comparison with sorafenib. In recent years, many studies have evaluated the dosimetry of SIRT using either a simulation-based dosimetry (macroaggregated albumin (MAA)-based) or a post-therapy-based one (90Y-based). The goal of this review is to present the dosimetry concept, tools available, its limitations, and main clinical results described for HCC patients treated with 90Y-loaded resin or glass microspheres. With MAA-based dosimetry, the threshold tumor doses allowing for a response were between 100 and 210 Gy for resin microspheres and between 205 and 257 Gy for glass microspheres. The significant impact of the tumor dose on OS was reported with both devices. The correlation between 90Y-based dosimetry and response was also reported. Regarding the safety, preliminary results are available for both products but with a larger range of normal liver doses values correlated with liver toxicities due to numerous confounding factors. Based on those results, international expert group recommendations for personalized dosimetry have been provided for both devices. The clinical impact of personalized dosimetry has been recently confirmed in a multicenter randomized study demonstrating a doubling of the response rate and an OS of 150% while using personalized dosimetry. Even if technical dosimetry improvements are still under investigation, the use of personalized dosimetry has to be generalized for both clinical practice and trial design.
Collapse
|