Elisei G, Pella A, Ricotti R, Via R, Fiore MR, Calvi G, Mastella E, Paganelli C, Tagaste B, Bello F, Fontana G, Meschini G, Buizza G, Valvo F, Orlandi E, Ciocca M, Baroni G. Development and validation of a new set-up simulator dedicated to ocular proton therapy at CNAO. Phys Med 2021; 82:228-239. [PMID: 33657472 DOI: 10.1016/j.ejmp.2021.01.070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 11/27/2020] [Accepted: 01/14/2021] [Indexed: 10/22/2022] Open
Abstract
An Eye Tracking System (ETS) is used at CNAO for providing a stable and reproducible ocular proton therapy (OPT) set-up, featuring a fixation light (FL) and monitoring stereo-cameras embedded in a rigid case. The aim of this work is to propose an ETS set-up simulation algorithm, that automatically provides the FL positioning in space, according to patient-specific gaze direction and avoiding interferences with patient, beam and collimator. Two configurations are provided: one in the CT room for acquiring images required for treatment planning with the patient lying on a couch, and one related to the treatment room with the patient sitting in front of the beam. Algorithm validation was performed reproducing ETS simulation (CT) and treatment (room) set-up for 30 patients previously treated at CNAO. The positioning accuracy of the device was quantified through a set of 14 control points applied to the ETS case and localizable both in the CT volume and in room X-ray images. Differences between the position of ETS reference points estimated by the algorithm and those measured by imaging systems are reported. The corresponding gaze direction deviation is on average 0.2° polar and 0.3° azimuth for positioning in CT room and 0.1° polar and 0.4° azimuth in the treatment room. The simulation algorithm was embedded in a clinically usable software application, which we assessed as capable of ensuring ETS positioning with an average accuracy of 2 mm in CT room and 1.5 mm in treatment room, corresponding to gaze direction deviations consistently lower than 1°.
Collapse
Affiliation(s)
- G Elisei
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy
| | - A Pella
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy.
| | - R Ricotti
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy
| | - R Via
- Center of Proton Therapy, Paul Scherrer Institut, 5232 Villigen, PSI, Switzerland
| | - M R Fiore
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department, Pavia, Italy
| | - G Calvi
- Centro Nazionale di Adroterapia Oncologica CNAO, Particle Accelerator Department, Pavia, Italy
| | - E Mastella
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department - Medical Physics Unit, Pavia, Italy
| | - C Paganelli
- Politecnico di Milano, Department of Electronics Information and Bioengineering, Milano, Italy
| | - B Tagaste
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy
| | - F Bello
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy
| | - G Fontana
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy
| | - G Meschini
- Politecnico di Milano, Department of Electronics Information and Bioengineering, Milano, Italy
| | - G Buizza
- Politecnico di Milano, Department of Electronics Information and Bioengineering, Milano, Italy
| | - F Valvo
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department, Pavia, Italy
| | - E Orlandi
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department, Pavia, Italy
| | - M Ciocca
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department - Medical Physics Unit, Pavia, Italy
| | - G Baroni
- Centro Nazionale di Adroterapia Oncologica CNAO, Clinical Department-Bioengineering Unit, Pavia, Italy; Politecnico di Milano, Department of Electronics Information and Bioengineering, Milano, Italy
| |
Collapse
|