1
|
Shahid T, Mandal S, Biswal SS, De A, Mukherjee M, Roy Chowdhury S, Chakrapani A, George K, Bhattacharya J, Soren P, Ghosh T, Sarkar B, Cozzi L. Preclinical validation and treatment of volumetric modulated arc therapy based total bone marrow irradiation in Halcyon™ ring gantry linear accelerator. Radiat Oncol 2022; 17:145. [PMID: 35986327 PMCID: PMC9389791 DOI: 10.1186/s13014-022-02109-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 07/26/2022] [Indexed: 11/16/2022] Open
Abstract
AIM This study aims to report preclinical validation, and the first clinical treatment of total bone marrow irradiation (TMI) and total bone marrow and lymph nodal irradiation (TMLI) using Volumetric modulated arc therapy in Halcyon-E ring gantry linear accelerator. Preclinical validation includes simulation, planning, patient-specific QA, and dry run. MATERIAL AND METHOD Four patients, two female and two male, with body weights of 116 kg, 52 kg, 64 kg, and 62 kg; with two with chronic myeloid leukemia, one each with acute lymphoblastic leukemia and acute myeloid leukemia (AML) were simulated and planned for TMI/TMLI. Patients were immobilized with a full-body vacuum bag. Head first supine (HFS) and Feet first supine (FFS) CT scans were acquired from head to knee and knee to toe. Planning target volume (PTV) was created with a uniform margin of 6 mm over the total bone marrow/bone marrow + lymph nodes. HFS and FFS PTVs were optimized independently using 6MV unflatten energy for 12 Gy in 6 fractions. Plans were merged to create the resultant dose distribution using a junction bias dose matching technique. The total number of isocenters was ≤ 10 per CT set, and two to four full arcs were used for each isocenter. A junction dose gradient technique was used for dose feathering between arcs between adjacent isocenters. RESULT Only one female patient diagnosed as AML received the TMLI treatment, while the other three patients dropped out due to clinical complications and comorbidities that developed in the time between simulation and treatment. The result presented has been averaged over all four patients. For PTV, 95% dose was normalised to 95% volume, PTV_V107% receiving 3.3 ± 3.1%. Total lung mean and V12Gy were 1048.6 ± 107.1 cGy and 19.5 ± 12.1%. Maximum lens doses were 489.5 ± 35.5 cGy (left: L) and 497 ± 69.2 cGy (right: R). The mean cardiac and bilateral kidney doses were 921.75 ± 89.2 cGy, 917.9 ± 63.2 cGy (L), and 805.9 ± 9.7 cGy (R). Average Monitor Unit was 7738.25 ± 1056.6. The median number of isocenters was 17(HFS+FFS), average MU/Dose (cGy) ratio per isocenter was 2.28 ± 0.3. CONCLUSION Halcyon-E ring gantry linear accelerator capable of planning and delivering TMI/TMLI..
Collapse
Affiliation(s)
- Tanweer Shahid
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Sourav Mandal
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | | | - Arundhati De
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Mukti Mukherjee
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | | | - Anupam Chakrapani
- Department of Hemato Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Kirubha George
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Jibak Bhattacharya
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Prosenjit Soren
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Tanmoy Ghosh
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India
| | - Biplab Sarkar
- Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India.
| | - Luca Cozzi
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Via Manzoni 56, 20089, Rozzano, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090, Pieve Emanuele, Milan, Italy
- Varian Medical Systems, Palo Alto, USA
| |
Collapse
|
2
|
The impact of different optimization strategies on the agreement between planned and delivered doses during volumetric modulated arc therapy for total marrow irradiation. Contemp Oncol (Pozn) 2021; 25:100-106. [PMID: 34667436 PMCID: PMC8506427 DOI: 10.5114/wo.2021.107742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 05/13/2021] [Indexed: 11/17/2022] Open
Abstract
Aim of the study To evaluate the agreement between planned and delivered doses and its potential correlation with the plans' complexity subjected to dosimetric verification. Material and methods Four isocentre volumetric modulated arc therapy for total marrow irradiation plans optimized simultaneously with (P1) and without (P2) MU reduction were evaluated dosimetrically by γ method performed in a global mode for 4 combinations of γ-index criteria (2%/2 mm, 2%/3 mm, 3%/2 mm, and 3%/3 mm). The evaluation was conducted for 4 regions (head and neck, chest, abdomen and upper pelvis, and lower pelvis and thighs) that were determined geometrically by the isocentres. The Wilcoxon test was used to detect significant differences between γ passing rate (GPR) analysis results for the P1 and P2 plans. The Pearson correlation was used to check the relationship between GPR and the plans' complexity. Results Except for the head and neck region, the P2 plans had better GPRs than the P1 plans. Only for hard combinations of γ-index criteria (i.e. 2%/3 mm, 2%/2 mm) were the GPRs differences between P1 and P2 clinically meaningful, and they were detected in the chest, abdomen and upper pelvis, and lower pelvis and thighs regions. The highest correlations between GPR and the indices describing the plans' complexity were found for the chest region. No correlation was found for the head and neck region. Conclusions The P2 plans showed better agreement between planned and delivered doses compared to the P1 plans. The GPR and the plans' complexity depend on the anatomy region and are most important for the chest region.
Collapse
|
3
|
Dibs K, Sim AJ, Peñagaricano JA, Latifi K, Garcia GA, Peters JA, Nieder ML, Kim S, Robinson TJ. Gonadal-sparing total body irradiation with the use of helical tomotherapy for nonmalignant indications. ACTA ACUST UNITED AC 2021; 26:153-158. [PMID: 34046227 DOI: 10.5603/rpor.a2021.0006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 12/24/2020] [Indexed: 11/25/2022]
Abstract
Background The aim was to demonstrate the feasibility and technique of gonadal sparing total body irradiation (TBI) with helical tomotherapy. Total body irradiation is a common part of the conditioning regimen prior to allogeneic stem cell transplantation. Shielding or dose-reduction to the gonads is often desired to preserve fertility, particularly in young patients undergoing transplant for non-malignant indications. Helical tomotherapy (HT) has been shown to be superior to traditional TBI delivery for organ at risk (OA R) doses and dose homogeneity. Materials and methods We present two representative cases (one male and one female) to illustrate the feasibility of this technique, each of whom received 3Gy in a single fraction prior to allogeneic stem cell transplant for benign indications. The planning target volume (PTV) included the whole body with a subtraction of OA Rs including the lungs, heart, and brain (each contracted by 1cm) as well as the gonads (testicles expanded by 5 cm and ovaries expanded by 0.5 cm). Results For the male patient we achieved a homogeneity index of 1.35 with a maximum and median planned dose to the testes of 0.53 Gy and 0.35 Gy, respectively. In-vivo dosimetry demonstrated an actual received dose of 0.48 Gy. For the female patient we achieved a homogeneity index of 1.13 with a maximum and median planned dose to the ovaries of 1.66 Gy and 0.86 Gy, respectively. Conclusion Gonadal sparing TBI is feasible and deliverable using HT in patients with non-malignant diseases requiring TBI as part of a pre-stem cell transplant conditioning regimen.
Collapse
Affiliation(s)
- Khaled Dibs
- Department of Radiation Oncology, The Ohio State University, Columbus OH, United States
| | - Austin J Sim
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - José A Peñagaricano
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - Kujtim Latifi
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - Genevieve A Garcia
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - Julia A Peters
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - Michael L Nieder
- Department of Blood and Marrow Transplant and Cellular Immunotherapy, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, United States
| | - Sungjune Kim
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| | - Timothy J Robinson
- Department of Radiation Oncology, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States.,Department of Biostatistics and Bioinformatics, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL, United States
| |
Collapse
|
4
|
Dose-escalated volumetric modulated arc therapy for total marrow irradiation: A feasibility dosimetric study with 4DCT planning and simultaneous integrated boost. Phys Med 2020; 78:123-128. [PMID: 33002733 DOI: 10.1016/j.ejmp.2020.09.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 08/31/2020] [Accepted: 09/15/2020] [Indexed: 11/20/2022] Open
Abstract
PURPOSE To evaluate the planning feasibility of dose-escalated total marrow irradiation (TMI) with simultaneous integrated boost (SIB) to the active bone marrow (ABM) using volumetric modulated arc therapy (VMAT), and to assess the impact of using planning organs at risk (OAR) volumes (PRV) accounting for breathing motion in the optimization. METHODS Five patients underwent whole-body CT and thoraco-abdominal 4DCT. A planning target volume (PTV) including all bones and ABM was contoured on each whole-body CT. PRV of selected OAR (liver, heart, kidneys, lungs, spleen, stomach) were determined with 4DCT. Planning consisted of 9-10 full 6 MV photon VMAT arcs. Four plans were created for each patient with 12 Gy prescribed to the PTV, with or without an additional 4 Gy SIB to the ABM. Planning dose constraints were set on the OAR or on the PRV. Planning objective was a PTV Dmean < 110% of the prescribed dose, a PTV V110% < 50%, and OAR Dmean ≤ 50-60%. RESULTS PTV Dmean < 110% was accomplished for most plans (n = 18/20), while all achieved V110%<50%. SIB plans succeeded to optimally cover the boost volume (median ABM Dmean = 16.3 Gy) and resulted in similar OAR sparing compared to plans without SIB (median OAR Dmean = 40-54% of the ABM prescribed dose). No statistically significant differences between plans optimized with constraints on OAR or PRV were found. CONCLUSIONS Adding a 4 Gy SIB to the ABM for TMI is feasible with VMAT technique, and results in OAR sparing similar to plans without SIB. Setting dose constraints on PRV does not impair PTV dosimetric parameters.
Collapse
|