1
|
Mutuwong C, Bootjomchai C, Chaiphaksa W, Cheewasukhanont W, Sommat V, Kaewjaeng S, Ornketphon O, Intachai N, Kothan S, Kim H, Kaewkhao J. Photon and thermal neutron shielding behaviors of aluminum calcium fluoroborate glass modified with barium oxide: FLUKA Monte Carlo, XCOM and experimental investigations. ANN NUCL ENERGY 2025; 210:110863. [DOI: 10.1016/j.anucene.2024.110863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2024]
|
2
|
Ornketphon O, Kaewjaeng S, Meejitpaisan P, Mutuwong C, Chaipaksa W, Sommat V, Kothan S, Kaewkhao J. Photon shielding properties of oxyfluoride aluminophosphate glass added with Sb2O3 by using PHITS Monte Carlo simulation and experimental methods. Radiat Phys Chem Oxf Engl 1993 2024; 224:111993. [DOI: 10.1016/j.radphyschem.2024.111993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2024]
|
3
|
Mutuwong C, Chaiphaksa W, Rachniyom W, Bootjomchai C, Intachai N, Cheewasukhanont W, Tuscharoen S, Sriwongsa K, Kothan S, Kaewkhao J. Comparative study of radiation ionizing on the MRCP-AM phantom before and after using the Bi2O3 −AlF3 −CaO −B2O3 shielding glass by PHITS Monte Carlo simulation. Radiat Phys Chem Oxf Engl 1993 2024; 223:111881. [DOI: 10.1016/j.radphyschem.2024.111881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2024]
|
4
|
Behmadi M, Toossi MTB, Nasseri S, Ravari ME, Momennezhad M, Gholamhosseinian H, Mohammadi M, Mdletshe S. Calculation of Organ Dose Distribution (in-field and Out-of-field) in Breast Cancer Radiotherapy on RANDO Phantom Using GEANT4 Application for Tomographic Emission (Gate) Monte Carlo Simulation. JOURNAL OF MEDICAL SIGNALS & SENSORS 2024; 14:18. [PMID: 39100743 PMCID: PMC11296572 DOI: 10.4103/jmss.jmss_25_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 02/02/2024] [Accepted: 03/05/2024] [Indexed: 08/06/2024]
Abstract
Introduction Organ dose distribution calculation in radiotherapy and knowledge about its side effects in cancer etiology is the most concern for medical physicists. Calculation of organ dose distribution for breast cancer treatment plans with Monte Carlo (MC) simulation is the main goal of this study. Materials and Methods Elekta Precise linear accelerator (LINAC) photon mode was simulated and verified using the GEANT4 application for tomographic emission. Eight different radiotherapy treatment plans on RANDO's phantom left breast were produced with the ISOgray treatment planning system (TPS). The simulated plans verified photon dose distribution in clinical tumor volume (CTV) with TPS dose volume histogram (DVH) and gamma index tools. To verify photon dose distribution in out-of-field organs, the point dose measurement results were compared with the same point doses in the MC simulation. Eventually, the DVHs for out-of-field organs that were extracted from the TPS and MC simulation were compared. Results Based on the implementation of gamma index tools with 2%/2 mm criteria, the simulated LINAC output demonstrated high agreement with the experimental measurements. Plan simulation for in-field and out-of-field organs had an acceptable agreement with TPS and experimental measurement, respectively. There was a difference between DVHs extracted from the TPS and MC simulation for out-of-field organs in low-dose parts. This difference is due to the inability of the TPS to calculate dose distribution in out-of-field organs. Conclusion and Discussion Based on the results, it was concluded that the treatment plans with the MC simulation have a high accuracy for the calculation of out-of-field dose distribution and could play a significant role in evaluating the important role of dose distribution for second primary cancer estimation.
Collapse
Affiliation(s)
- Marziyeh Behmadi
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Mohammad Taghi Bahreyni Toossi
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Shahrokh Nasseri
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ehsan Ravari
- Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
- Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Mahdi Momennezhad
- Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamid Gholamhosseinian
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Mohammadi
- Department of Medical Physics, Royal Adelaide Hospital, Adelaide, Australia
| | - Sibusiso Mdletshe
- Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
5
|
Ahmad H, Ali J, Ahmad K, Biradar G, Zaman A, Uddin Y, Sohail M, Ali S. Assessment of peripheral dose as a function of distance and depth from cobalt-60 beam in water phantom using TLD-100. J Egypt Natl Canc Inst 2024; 36:22. [PMID: 38910202 DOI: 10.1186/s43046-024-00227-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 05/08/2024] [Indexed: 06/25/2024] Open
Abstract
BACKGROUND Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100). METHODS The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm2 field size at constant source to surface distance (SSD) of 80 cm. RESULTS The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor. CONCLUSION It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.
Collapse
Affiliation(s)
- Habib Ahmad
- Swat Institute of Nuclear Medicine, Oncology & Radiotherapy (SINOR) Cancer Hospital, Saidu Sharif Swat, KPK, Pakistan
| | - Javaid Ali
- Larkana Institute of Nuclear Medicine and Radiotherapy (LINAR) Cancer Hospital, Larkana, Sindh, Pakistan.
| | - Khalil Ahmad
- Pakistan Institute of Nuclear Science and Technology (PINSTECH), Islamabad, Pakistan
| | - Ghufran Biradar
- Swat Institute of Nuclear Medicine, Oncology & Radiotherapy (SINOR) Cancer Hospital, Saidu Sharif Swat, KPK, Pakistan
| | - Ashfaq Zaman
- Swat Institute of Nuclear Medicine, Oncology & Radiotherapy (SINOR) Cancer Hospital, Saidu Sharif Swat, KPK, Pakistan
| | - Yasir Uddin
- Royal College of Nursing, Saidu Sharif, Swat, KPK, Pakistan
| | - Muhammad Sohail
- International Collaborative Laboratory of 2D Materials for Optoelectronics Science and Technology of Ministry of Education, Institute of Microscale Optoelectronics, College of Electronics and Information Engineering, Shenzhen University, Shenzhen, 518060, China
| | - Shahid Ali
- Department of Physics, University of Peshawar (UOP), Peshawar, KPK, Pakistan
| |
Collapse
|
6
|
Muñoz-Hernández IS, Espinoza I, López-Martínez IN, Sánchez-Nieto B. IS 2aR, a computational tool to transform voxelized reference phantoms into patient-specific whole-body virtual CTs for peripheral dose estimation. Phys Med 2023; 116:103183. [PMID: 38000102 DOI: 10.1016/j.ejmp.2023.103183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/30/2023] [Accepted: 11/19/2023] [Indexed: 11/26/2023] Open
Abstract
BACKGROUND The risk of radiogenic cancer induction due to radiotherapy depends on the dose received by the patient's organs. Knowing the position of all organs is needed to assess this dose in a personalized way. However, radiotherapy planning computed tomography (pCT) scans contain truncated patient anatomy, limiting personalized dose evaluation. PURPOSE To develop a simple and freely available computational tool that adapts an ICRP reference computational phantom to generate a patient-specific whole-body CT for peripheral dose computations. METHODS Various bone-segmentation methods were explored onto fifteen pCTs, and the one with the highest Sørensen-Dice coefficient was implemented. The reference phantom is registered to the pCT, obtaining a registration transform matrix, which is then applied to create the whole-body virtual CT. Additional validation involved a comparison of absorbed doses to organs delineated on both the pCT and the virtual CT. RESULTS A dedicated graphical user interface was designed and implemented to house the developed functions for i) selecting a registration region on which automatic bone segmentation and rigid registration will occur, ii) displaying the results of these processes under selectable views, and iii) exporting the final patient-specific whole-body CT. This software was termed IS2aR. The tested whole-body virtual CT generated by IS2aR fulfilled our requirements. CONCLUSIONS IS2aR is a user-friendly computational software to create a personalized whole-body CT containing the original structures in the reference phantom. The personalized dose deposited in peripheral organs can be estimated further to assess second cancer induction risk in epidemiological studies.
Collapse
Affiliation(s)
| | - Ignacio Espinoza
- Institute of Physics, Pontificia Universidad Católica de Chile, Santiago, Chile.
| | | | | |
Collapse
|
7
|
He D, Zhang J, Xiang Y, Wu P, Li G, Chang H, Wang Q, Shao Q, Zhu S. Association between radiotherapy for surgically treated oral cavity cancer and secondary lung cancer. Front Public Health 2023; 11:1120671. [PMID: 37033050 PMCID: PMC10073750 DOI: 10.3389/fpubh.2023.1120671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 03/03/2023] [Indexed: 04/11/2023] Open
Abstract
Background There is limited research on the incidence of secondary lung cancer (SLC) after radiotherapy (RT) for oral cavity cancer (OCC). Therefore, we investigated the association between RT for OCC and the risk of SLC and the overall survival of these patients. Methods Patients diagnosed with OCC between 1975 and 2015 were selected from the Surveillance, Epidemiology, and End Results database. The cumulative incidence of SLC, relative risk (RR) of RT vs. no RT (NRT), standardized incidence ratios (SIR), and survival outcomes were assessed. Results A total of 10,936 patients with OCC were included. Of these, 429 (3.92%) patients developed SLC, where 136 (5.02%) received RT and 293 (3.56%) did not. The cumulative incidence of SLC during follow-up was 6.89% and 4.84% in the RT and NRT patients, respectively. RT was associated with a higher risk of SLC. In the subset analysis, the results showed that a higher risk of developing SLC among patients with index OCC in most subgroups. Dynamic RR and SIR revealed a decreased risk of SLC with increasing latency time. No difference was observed in the 10-year survival rates for patients with SLC who received RT or not or compared with primary lung cancer. Conclusion RT was associated with a higher risk of SLC, and patients diagnosed with OCC could be followed for 5-10 years after diagnosis.
Collapse
Affiliation(s)
- Dongjie He
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Jun Zhang
- Department of Otolaryngology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Ying Xiang
- Department of Traditional Chinese Medicine, The Sixth Medical Center of PLA General Hospital, Beijing, China
| | - Peiwen Wu
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Gaiyan Li
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Hao Chang
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Qiming Wang
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Qiuju Shao
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
| | - Siying Zhu
- Department of Radiation Oncology, Tangdu Hospital, The Second Affiliated Hospital of Air Force Military Medical University, Xi'an, China
- *Correspondence: Siying Zhu
| |
Collapse
|
8
|
Sánchez-Nieto B, Stolarczyk L, Dasu A, Newhauser WD, Sánchez-Doblado F. Editorial: Out-of-field second primary cancer induction: Dosimetry and modelling. Front Oncol 2022; 12:1076792. [PMID: 36544702 PMCID: PMC9761579 DOI: 10.3389/fonc.2022.1076792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 10/28/2022] [Indexed: 12/07/2022] Open
Affiliation(s)
- Beatriz Sánchez-Nieto
- Institute of Physics, Faculty of Physics, Pontifical Catholic University of Chile, Santiago, Chile,*Correspondence: Beatriz Sánchez-Nieto,
| | - Liliana Stolarczyk
- Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark,The Henryk Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland
| | - Alexandru Dasu
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden,The Skandion Clinic, Uppsala, Sweden
| | - Wayne D. Newhauser
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, United States
| | | |
Collapse
|
9
|
Pazzaglia S, Eidemüller M, Lumniczky K, Mancuso M, Ramadan R, Stolarczyk L, Moertl S. Out-of-field effects: lessons learned from partial body exposure. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2022; 61:485-504. [PMID: 36001144 PMCID: PMC9722818 DOI: 10.1007/s00411-022-00988-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 08/03/2022] [Indexed: 05/27/2023]
Abstract
Partial body exposure and inhomogeneous dose delivery are features of the majority of medical and occupational exposure situations. However, mounting evidence indicates that the effects of partial body exposure are not limited to the irradiated area but also have systemic effects that are propagated outside the irradiated field. It was the aim of the "Partial body exposure" session within the MELODI workshop 2020 to discuss recent developments and insights into this field by covering clinical, epidemiological, dosimetric as well as mechanistic aspects. Especially the impact of out-of-field effects on dysfunctions of immune cells, cardiovascular diseases and effects on the brain were debated. The presentations at the workshop acknowledged the relevance of out-of-field effects as components of the cellular and organismal radiation response. Furthermore, their importance for the understanding of radiation-induced pathologies, for the discovery of early disease biomarkers and for the identification of high-risk organs after inhomogeneous exposure was emphasized. With the rapid advancement of clinical treatment modalities, including new dose rates and distributions a better understanding of individual health risk is urgently needed. To achieve this, a deeper mechanistic understanding of out-of-field effects in close connection to improved modelling was suggested as priorities for future research. This will support the amelioration of risk models and the personalization of risk assessments for cancer and non-cancer effects after partial body irradiation.
Collapse
Affiliation(s)
- S. Pazzaglia
- Laboratory of Biomedical Technologies, ENEA CR-Casaccia, Via Anguillarese 301, 00123 Rome, Italy
| | - M. Eidemüller
- Institute of Radiation Medicine, Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764 Neuherberg, Germany
| | - K. Lumniczky
- Department of Radiobiology and Radiohygiene, Unit of Radiation Medicine, National Public Health Centre, Albert Florian u. 2-6, 1097 Budapest, Hungary
| | - M. Mancuso
- Laboratory of Biomedical Technologies, ENEA CR-Casaccia, Via Anguillarese 301, 00123 Rome, Italy
| | - R. Ramadan
- Radiobiology Unit, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | - L. Stolarczyk
- Danish Centre for Particle Therapy, Palle Juul-Jensens Boulevard 25, 8200 Aarhus N, Denmark
| | - S. Moertl
- Federal Office for Radiation Protection, Ingolstädter Landstr. 1, 85764 Oberschleißheim, Germany
| |
Collapse
|
10
|
3D-CRT, IMRT and VMAT for flank irradiation due to pediatric Wilms tumor: A comparative planning study with XCAT phantoms. Phys Med 2022; 103:89-97. [DOI: 10.1016/j.ejmp.2022.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/02/2022] [Accepted: 10/07/2022] [Indexed: 11/17/2022] Open
|
11
|
Sánchez-Nieto B, López-Martínez IN, Rodríguez-Mongua JL, Espinoza I. A simple analytical model for a fast 3D assessment of peripheral photon dose during coplanar isocentric photon radiotherapy. Front Oncol 2022; 12:872752. [PMID: 36276161 PMCID: PMC9583866 DOI: 10.3389/fonc.2022.872752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 09/09/2022] [Indexed: 11/13/2022] Open
Abstract
Considering that cancer survival rates have been growing and that nearly two-thirds of those survivors were exposed to clinical radiation during its treatment, the study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. To correctly assess this risk, knowing the dose to out-of-field organs is essential. As it has been reported, commercial treatment planning systems do not accurately calculate the dose far away from the border of the field; analytical dose estimation models may help this purpose. In this work, the development and validation of a new three-dimensional (3D) analytical model to assess the photon peripheral dose during radiotherapy is presented. It needs only two treatment-specific input parameter values, plus information about the linac-specific leakage, when available. It is easy to use and generates 3D whole-body dose distributions and, particularly, the dose to out-of-field organs (as dose–volume histograms) outside the 5% isodose for any isocentric treatment using coplanar beams [including intensity modulated radiotherapy and volumetric modulated arc therapy (VMAT)]. The model was configured with the corresponding Monte Carlo simulation of the peripheral absorbed dose for a 6 MV abdomen treatment on the International Comission on Radiological Protection (ICRP) 110 computational phantom. It was then validated with experimental measurements using thermoluminescent dosimeters in the male ATOM anthropomorphic phantom irradiated with a VMAT treatment for prostate cancer. Additionally, its performance was challenged by applying it to a lung radiotherapy treatment very different from the one used for training. The model agreed well with measurements and simulated dose values. A graphical user interface was developed as a first step to making this work more approachable to a daily clinical application.
Collapse
Affiliation(s)
- Beatriz Sánchez-Nieto
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
- *Correspondence: Beatriz Sánchez-Nieto,
| | | | | | - Ignacio Espinoza
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
12
|
Fetal dose estimation for Virtual Tangential-fields Arc Therapy whole breast irradiation by optically stimulated luminescence dosimeters. Phys Med 2022; 101:44-49. [PMID: 35944444 DOI: 10.1016/j.ejmp.2022.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 06/14/2022] [Accepted: 07/27/2022] [Indexed: 11/21/2022] Open
Abstract
Breast cancer is the most frequently diagnosed tumor in pregnant women and radiation therapy should carefully be weighted up because of the dose to the fetus. The aim of this study was to investigate fetal dose in a patient treated with Virtual Tangential-fields Arc Therapy (ViTAT), an innovative technique for whole breast irradiation. Optically stimulated luminescence detectors (OSLDs) were calibrated on a Varian TrueBeam linac, with both a 6X and 6XFFF beam quality, and used for out-of-field measurements. Fetal dose related with ViTAT technique was compared to the standard 3D conformal radiation therapy technique (3DCRT). The fetal dose delivered with a ViTAT technique planned with 6XFFF beam was also investigated. Measurements were taken on a phantom composed of Rando Alderson Phantom slices and solid water slabs. OSLDs were placed in a region identified by the height of the fundus from conception to the twentieth week using a custom made PMMA grid. Due to the higher number of monitor units, the peripheral dose of ViTAT delivered with 6X beams is higher than that of 3DCRT. However, nanoDots measurements prove that ViTAT can be used in place of 3DCRT while maintaining similar fetal dose levels if 6XFFF beams are used.
Collapse
|
13
|
Moghaddasi L, Colyer C. Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study. Phys Med 2022; 98:53-62. [DOI: 10.1016/j.ejmp.2022.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 04/13/2022] [Accepted: 04/22/2022] [Indexed: 10/18/2022] Open
|
14
|
Romero-Expósito M, Toma-Dasu I, Dasu A. Determining Out-of-Field Doses and Second Cancer Risk From Proton Therapy in Young Patients—An Overview. Front Oncol 2022; 12:892078. [PMID: 35712488 PMCID: PMC9197425 DOI: 10.3389/fonc.2022.892078] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 05/02/2022] [Indexed: 11/13/2022] Open
Abstract
Proton therapy has the potential to provide survival and tumor control outcomes comparable and frequently superior to photon therapy. This has led to a significant concern in the medical physics community on the risk for the induction of second cancers in all patients and especially in younger patients, as they are considered more radiosensitive than adults and have an even longer expected lifetime after treatment. Thus, our purpose is to present an overview of the research carried out on the evaluation of out-of-field doses linked to second cancer induction and the prediction of this risk. Most investigations consisted of Monte Carlo simulations in passive beam facilities for clinical scenarios. These works established that equivalent doses in organs could be up to 200 mSv or 900 mSv for a brain or a craniospinal treatment, respectively. The major contribution to this dose comes from the secondary neutrons produced in the beam line elements. Few works focused on scanned-beam facilities, but available data show that, for these facilities, equivalent doses could be between 2 and 50 times lower. Patient age is a relevant factor in the dose level, especially for younger patients (by means of the size of the body) and, in addition, in the predicted risk by models (due to the age dependence of the radiosensitivity). For risks, the sex of the patient also plays an important role, as female patients show higher sensitivity to radiation. Thus, predicted risks of craniospinal irradiation can range from 8% for a 15-year-old male patient to 58% for a 2-year-old female patient, using a risk model from a radiological protection field. These values must be taken with caution due to uncertainties in risk models, and then dosimetric evaluation of stray radiation becomes mandatory in order to complement epidemiological studies and be able to model appropriate dose–response functions for this dose range. In this sense, analytical models represent a useful tool and some models have been implemented to be used for young patients. Research carried out so far confirmed that proton beam therapy reduces the out-of-field doses and second cancer risk. However, further investigations may be required in scanned-beam delivery systems.
Collapse
Affiliation(s)
- Maite Romero-Expósito
- The Skandion Clinic, Uppsala, Sweden
- Oncology Pathology Department, Karolinska Institutet, Stockholm, Sweden
- *Correspondence: Maite Romero-Expósito,
| | - Iuliana Toma-Dasu
- Oncology Pathology Department, Karolinska Institutet, Stockholm, Sweden
- Medical Radiation Physics, Stockholm University, Stockholm, Sweden
| | - Alexandru Dasu
- The Skandion Clinic, Uppsala, Sweden
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| |
Collapse
|