1
|
Khanolkar A, Thorat V, Patil B, Samanta G. Towards a real-time release of blends and tablets using NIR and Raman spectroscopy at commercial scales. Pharm Dev Technol 2023; 28:265-276. [PMID: 36847606 DOI: 10.1080/10837450.2023.2185256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/31/2023] [Accepted: 02/20/2023] [Indexed: 03/01/2023]
Abstract
Near Infrared and Raman spectroscopy-based Process Analytical Technology tools were used for monitoring blend uniformity (BU) and content uniformity (CU) for solid oral formulations. A quantitative Partial Least Square model was developed to monitor BU as real-time release testing at a commercial scale. The model having the R2, and root mean square error of 0.9724 and 2.2047, respectively can predict the target concentration of 100% with a 95% confidence interval of 101.85-102.68% even after one year. The tablets from the same blends were investigated for CU using NIR and Raman techniques both in reflection and transmission mode. Raman reflection technique was found to be the best and the PLS model was developed using tablets compressed at different concentrations, hardness, and speed. The model with R2 and RMSE of 0.9766 and 1.9259, respectively was used for the quantification of CU. Both the BU and CU models were validated for accuracy, precision, specificity, linearity, and robustness. The accuracy was proved against the HPLC method with a relative standard deviation of less than 3%. The equivalency for BU by NIR and CU by Raman was evaluated using Schuirmann's Two One-sided tests and found equivalent to HPLC within a 2% acceptable limit.
Collapse
Affiliation(s)
- Aruna Khanolkar
- QbD Department, Integrated Product Development, Cipla Ltd, Mumbai, Maharashtra, India
| | - Viraj Thorat
- QbD Department, Integrated Product Development, Cipla Ltd, Mumbai, Maharashtra, India
| | - Bhaskar Patil
- QbD Department, Integrated Product Development, Cipla Ltd, Mumbai, Maharashtra, India
| | - Gautam Samanta
- QbD Department, Integrated Product Development, Cipla Ltd, Mumbai, Maharashtra, India
| |
Collapse
|
2
|
Zhou Y, Li F, Sanders C, Samain S, Salman A. Online monitoring of dry powder mixing in a bin mixer. POWDER TECHNOL 2022. [DOI: 10.1016/j.powtec.2022.118081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
3
|
Talwar S, Pawar P, Wu H, Sowrirajan K, Wu S, Igne B, Friedman R, Muzzio FJ, Drennen JK. NIR Spectroscopy as an Online PAT Tool for a Narrow Therapeutic Index Drug: Toward a Platform Approach Across Lab and Pilot Scales for Development of a Powder Blending Monitoring Method and Endpoint Determination. AAPS J 2022; 24:103. [PMID: 36171513 DOI: 10.1208/s12248-022-00748-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Accepted: 08/31/2022] [Indexed: 01/18/2023] Open
Abstract
An online near-infrared (NIR) spectroscopy platform system for real-time powder blending monitoring and blend endpoint determination was tested for a phenytoin sodium formulation. The study utilized robust experimental design and multiple sensors to investigate multivariate data acquisition, model development, and model scale-up from lab to manufacturing. The impact of the selection of various blend endpoint algorithms on predicted blend endpoint (i.e., mixing time) was explored. Spectral data collected at two process scales using two NIR spectrometers was incorporated in a single (global) calibration model. Unique endpoints were obtained with different algorithms based on standard deviation, average, and distributions of concentration prediction for major components of the formulation. Control over phenytoin sodium's distribution was considered critical due to its narrow therapeutic index nature. It was found that algorithms sensitive to deviation from target concentration offered the simplest interpretation and consistent trends. In contrast, algorithms sensitive to global homogeneity of active and excipients yielded the longest mixing time to achieve blending endpoint. However, they were potentially more sensitive to subtle uniformity variations. Qualitative algorithms using principal component analysis (PCA) of spectral data yielded the prediction of shortest mixing time for blending endpoint. The hybrid approach of combining NIR data from different scales presents several advantages. It enables simplifying the chemometrics model building process and reduces the cost of model building compared to the approach of using data solely from commercial scale. Success of such a hybrid approach depends on the spectroscopic variability captured at different scales and their relative contributions in the final NIR model.
Collapse
Affiliation(s)
- Sameer Talwar
- Duquesne University Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA, 15282, USA.,MST-BPDS-Biopharm Product Dev & Supply, GSK, 709 Swedeland Road, King of Prussia, PA, 19406, USA
| | - Pallavi Pawar
- Department of Chemical and Biochemical Engineering, Rutgers University, 98 Brett Road, Piscataway, NJ, 08854, USA.,Gilead, Foster City, CA, 94404, USA
| | - Huiquan Wu
- Office of Pharmaceutical Quality, CDER, FDA, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA.
| | - Koushik Sowrirajan
- Office of Pharmaceutical Quality, CDER, FDA, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Suyang Wu
- Office of Pharmaceutical Quality, CDER, FDA, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Benoît Igne
- Duquesne University Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA, 15282, USA
| | - Richard Friedman
- Office of Manufacturing Quality, Office of Compliance, CDER, FDA, Silver Spring, MD, 20993, USA
| | - Fernando J Muzzio
- Department of Chemical and Biochemical Engineering, Rutgers University, 98 Brett Road, Piscataway, NJ, 08854, USA
| | - James K Drennen
- Duquesne University Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA, 15282, USA.
| |
Collapse
|
4
|
Khanolkar A, Patil B, Thorat V, Samanta G. Development of Inline Near-Infrared Spectroscopy Method for Real-Time Monitoring of Blend Uniformity of Direct Compression and Granulation-Based Products at Commercial Scales. AAPS PharmSciTech 2022; 23:235. [PMID: 36002672 DOI: 10.1208/s12249-022-02392-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 08/08/2022] [Indexed: 11/30/2022] Open
Abstract
Blending is a critical intermediate unit operation for all solid oral formulations. For blend uniformity testing, API content in the blend must be quantified precisely. A detailed study was conducted to demonstrate the suitability of inline NIR (near-infrared) spectroscopy for blend uniformity testing of two solid oral formulations: existing direct compression (DC) product with a multistep blending process and granulation-based product with API granules. Both qualitative and quantitative methods were developed at a laboratory scale using statistical moving block standard deviation (MBSD) and multivariate data analysis such as principal component analysis (PCA) and partial least squares (PLS) regression. The qualitative MBSD method demonstrated that there was no need for multiple steps for the existing DC product. Hence, a simplified single-step process was developed for blending. Quantitative PLS models for blending processes of both the products were developed, validated, and successfully implemented at a commercial scale for the real-time release of blends. Results obtained from the validated model were in good agreement with the current method of sampling and chromatography.
Collapse
Affiliation(s)
- Aruna Khanolkar
- QbD Department, Integrated Product Development, Cipla Ltd., Maharashtra, Mumbai, India
| | - Bhaskar Patil
- QbD Department, Integrated Product Development, Cipla Ltd., Maharashtra, Mumbai, India
| | - Viraj Thorat
- QbD Department, Integrated Product Development, Cipla Ltd., Maharashtra, Mumbai, India
| | - Gautam Samanta
- QbD Department, Integrated Product Development, Cipla Ltd., Maharashtra, Mumbai, India.
| |
Collapse
|
5
|
Zhong L, Gao L, Li L, Nei L, Wei Y, Zhang K, Zhang H, Yin W, Xu D, Zang H. Method development and validation of a near-infrared spectroscopic method for in-line API quantification during fluidized bed granulation. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 274:121078. [PMID: 35248859 DOI: 10.1016/j.saa.2022.121078] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 02/11/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Near-infrared spectroscopy (NIRS) is an excellent process analytical technology (PAT) tool for active pharmaceutical ingredient (API) quantification during fluidized granulation. Therefore, a portable near-infrared spectrometer combined with a new innovative method of extended iterative optimization technique (EIOT) was used to in-line monitor the API content uniformity during fluidized bed granulation. The principal component analysis (PCA) and partial least squares regression (PLSR) were also used to characterize and predict API concentration with changes from 75% to 125% of the label claim to prove the superiority of EIOT. The API content prediction accuracy of the EIOT method was verified through offline High Performance Liquid Chromatography (HPLC) measurement. Also, the spatial distribution of API in granules was visualized by Raman imaging technology. The results showed that the established NIRS method was suitable for the prediction of API content in fluidized bed granulation, which provides a new idea for the determination of API content during granulation.
Collapse
Affiliation(s)
- Liang Zhong
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Lele Gao
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Lian Li
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Lei Nei
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Yongheng Wei
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Kefan Zhang
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Hui Zhang
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China
| | - Wenping Yin
- Shandong SMA Pharmatech Co., Ltd, 165, Huabei Rd., High & New Technology Zone, Zibo, Shandong 0533, China
| | - Dongbo Xu
- Shandong SMA Pharmatech Co., Ltd, 165, Huabei Rd., High & New Technology Zone, Zibo, Shandong 0533, China
| | - Hengchang Zang
- NMPA Key Laboratory for Technology Research and Evaluation of Drug Products, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan 250012, Shandong, China; National Glycoengineering Research Center, Shandong University, Jinan 250012, Shandong, China; Key Laboratory of Chemical Biology (Ministry of Education), Shandong University, Jinan 250012, China.
| |
Collapse
|
6
|
Zhang K, Wang H, Zhong L, Liu L, Huang R, Zhang H, Xu D, Yin W, Li L, Zang H. Evaluation and Monitoring of the API Content of a Portable Near Infrared Instrument Combined with Chemometrics Based on Fluidized Bed Mixing Process. J Pharm Innov 2021. [DOI: 10.1007/s12247-021-09581-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Kim EJ, Kim JH, Kim MS, Jeong SH, Choi DH. Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification. Pharmaceutics 2021; 13:919. [PMID: 34205797 PMCID: PMC8234957 DOI: 10.3390/pharmaceutics13060919] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/31/2021] [Accepted: 06/16/2021] [Indexed: 11/16/2022] Open
Abstract
Various frameworks and methods, such as quality by design (QbD), real time release test (RTRT), and continuous process verification (CPV), have been introduced to improve drug product quality in the pharmaceutical industry. The methods recognize that an appropriate combination of process controls and predefined material attributes and intermediate quality attributes (IQAs) during processing may provide greater assurance of product quality than end-product testing. The efficient analysis method to monitor the relationship between process and quality should be used. Process analytical technology (PAT) was introduced to analyze IQAs during the process of establishing regulatory specifications and facilitating continuous manufacturing improvement. Although PAT was introduced in the pharmaceutical industry in the early 21st century, new PAT tools have been introduced during the last 20 years. In this review, we present the recent pharmaceutical PAT tools and their application in pharmaceutical unit operations. Based on unit operations, the significant IQAs monitored by PAT are presented to establish a control strategy for CPV and real time release testing (RTRT). In addition, the equipment type used in unit operation, PAT tools, multivariate statistical tools, and mathematical preprocessing are introduced, along with relevant literature. This review suggests that various PAT tools are rapidly advancing, and various IQAs are efficiently and precisely monitored in the pharmaceutical industry. Therefore, PAT could be a fundamental tool for the present QbD and CPV to improve drug product quality.
Collapse
Affiliation(s)
- Eun Ji Kim
- Department of Pharmaceutical Engineering, Inje University, Gimhae-si, Gyeongnam 621-749, Korea; (E.J.K.); (J.H.K.)
| | - Ji Hyeon Kim
- Department of Pharmaceutical Engineering, Inje University, Gimhae-si, Gyeongnam 621-749, Korea; (E.J.K.); (J.H.K.)
| | - Min-Soo Kim
- College of Pharmacy, Pusan National University, Busandaehak-ro 63 heon-gil, Geumjeong-gu, Busan 46241, Korea;
| | - Seong Hoon Jeong
- College of Pharmacy, Dongguk University-Seoul, Dongguk-ro-32, Ilsan-Donggu, Goyang 10326, Korea;
| | - Du Hyung Choi
- Department of Pharmaceutical Engineering, Inje University, Gimhae-si, Gyeongnam 621-749, Korea; (E.J.K.); (J.H.K.)
| |
Collapse
|
8
|
Shi G, Lin L, Liu Y, Chen G, Luo Y, Wu Y, Li H. Pharmaceutical application of multivariate modelling techniques: a review on the manufacturing of tablets. RSC Adv 2021; 11:8323-8345. [PMID: 35423324 PMCID: PMC8695199 DOI: 10.1039/d0ra08030f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 01/26/2021] [Indexed: 11/21/2022] Open
Abstract
The tablet manufacturing process is a complex system, especially in continuous manufacturing (CM). It includes multiple unit operations, such as mixing, granulation, and tableting. In tablet manufacturing, critical quality attributes are influenced by multiple factorial relationships between material properties, process variables, and interactions. Moreover, the variation in raw material attributes and manufacturing processes is an inherent characteristic and seriously affects the quality of pharmaceutical products. To deepen our understanding of the tablet manufacturing process, multivariable modeling techniques can replace univariate analysis to investigate tablet manufacturing. In this review, the roles of the most prominent multivariate modeling techniques in the tablet manufacturing process are discussed. The review mainly focuses on applying multivariate modeling techniques to process understanding, optimization, process monitoring, and process control within multiple unit operations. To minimize the errors in the process of modeling, good modeling practice (GMoP) was introduced into the pharmaceutical process. Furthermore, current progress in the continuous manufacturing of tablets and the role of multivariate modeling techniques in continuous manufacturing are introduced. In this review, information is provided to both researchers and manufacturers to improve tablet quality.
Collapse
Affiliation(s)
- Guolin Shi
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Longfei Lin
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Yuling Liu
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Gongsen Chen
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Yuting Luo
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Yanqiu Wu
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| | - Hui Li
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700 China
| |
Collapse
|
9
|
Pedersen T, Karttunen AP, Korhonen O, Wu JX, Naelapää K, Skibsted E, Rantanen J. Determination of Residence Time Distribution in a Continuous Powder Mixing Process With Supervised and Unsupervised Modeling of In-line Near Infrared (NIR) Spectroscopic Data. J Pharm Sci 2020; 110:1259-1269. [PMID: 33217424 DOI: 10.1016/j.xphs.2020.10.067] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/12/2020] [Accepted: 10/30/2020] [Indexed: 11/25/2022]
Abstract
Successful implementation of continuous manufacturing processes requires robust methods to assess and control product quality in a real-time mode. In this study, the residence time distribution of a continuous powder mixing process was investigated via pulse tracer experiments using near infrared spectroscopy for tracer detection in an in-line mode. The residence time distribution was modeled by applying the continuous stirred tank reactor in series model for achieving the tracer (paracetamol) concentration profiles. Partial least squares discriminant analysis and principal component analysis of the near infrared spectroscopy data were applied to investigate both supervised and unsupervised chemometric modeling approaches. Additionally, the mean residence time for three powder systems was measured with different process settings. It was found that a significant change in the mean residence time occurred when comparing powder systems with different flowability and mixing process settings. This study also confirmed that the partial least squares discriminant analysis applied as a supervised chemometric model enabled an efficient and fast estimate of the mean residence time based on pulse tracer experiments.
Collapse
Affiliation(s)
- Troels Pedersen
- University of Copenhagen, Copenhagen, Denmark; Novo Nordisk A/S, Måløv, Denmark
| | | | | | | | | | | | | |
Collapse
|
10
|
Quintelas C, Melo A, Costa M, Mesquita DP, Ferreira EC, Amaral AL. Environmentally-friendly technology for rapid identification and quantification of emerging pollutants from wastewater using infrared spectroscopy. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2020; 80:103458. [PMID: 32710934 DOI: 10.1016/j.etap.2020.103458] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 07/14/2020] [Accepted: 07/20/2020] [Indexed: 06/11/2023]
Abstract
The monitoring of emerging pollutants in wastewaters is nowadays an issue of special concern, with the classical quantification methods being time and reagent consuming. In this sense, a FTIR transmission spectroscopy based chemometric methodology was developed for the determination of eight of these pollutants. A total of 456 samples were, therefore, obtained, from an activated sludge wastewater treatment process spiked with the studied pollutants, and analysed in the range of 200 cm-1 to 14,000 cm-1. Then, a k-nearest neighbour (kNN) analysis aiming at identifying each sample pollutant was employed. Next, partial least squares (PLS) and ordinary least squares (OLS) modelling approaches were employed in order to obtain suitable prediction models. This procedure resulted in good prediction abilities regarding the estimation of atrazine, desloratadine, paracetamol, β-estradiol, ibuprofen, carbamazepine, sulfamethoxazole and ethynylestradiol concentrations in wastewaters. These promising results suggest this technology as a fast, eco-friendly and reagent free alternative methodology for the quantification of emerging pollutants in wastewaters.
Collapse
Affiliation(s)
- C Quintelas
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal.
| | - A Melo
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - M Costa
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - D P Mesquita
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - E C Ferreira
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - A L Amaral
- CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal; Instituto Politécnico de Coimbra, ISEC, DEQB, Rua Pedro Nunes, Quinta da Nora, 3030-199 Coimbra, Portugal
| |
Collapse
|
11
|
Zhong L, Gao L, Li L, Zang H. Trends-process analytical technology in solid oral dosage manufacturing. Eur J Pharm Biopharm 2020; 153:187-199. [DOI: 10.1016/j.ejpb.2020.06.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 06/11/2020] [Accepted: 06/14/2020] [Indexed: 10/24/2022]
|
12
|
Bowler AL, Bakalis S, Watson NJ. A review of in-line and on-line measurement techniques to monitor industrial mixing processes. Chem Eng Res Des 2020. [DOI: 10.1016/j.cherd.2019.10.045] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Du C, Dai S, Zhao A, Qiao Y, Wu Z. Optimization of PLS modeling parameters via quality by design concept for Gardenia jasminoides Ellis using online NIR sensor. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 222:117267. [PMID: 31247389 DOI: 10.1016/j.saa.2019.117267] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 05/14/2019] [Accepted: 06/09/2019] [Indexed: 06/09/2023]
Abstract
This paper discussed the process parameters optimization of partial least-square (PLS) modeling according to quality by design (QbD) concept. D-optimal design and online near-infrared (NIR) sensor were proposed to analysis the Geniposide in Gardenia jasminoides Ellis using above process parameters to achieve robustness PLS model. Four critical model parameters (CMPs) were identified to construct a D-optimal design, which included the selection of sample set, spectra pre-processing, latent variables and variable selection methods. NIR sensor dataset was obtained under a pilot scale system. The D-optimal design optimization strategy resulted in a robust PLS model with the optimal parameters, 1/2 samples for calibration sets through Baseline spectra pre-processing with SiPLS-selecting variables under 8 factors. The critical evaluation attributes (CEAs) of PLS model were recommended as follows: the RMSEC and Rcal2 of the calibration set were 0.005901 and 0.9983. The RMSEP and Rpre2 of the validation set were 0.02002 and 0.9845. The multivariate detection limit (MDL) was 1.143 × 10-3. Therefore, design space of CMPs which affected CEAs of PLS model was established. The result demonstrated that the proposed method was beneficial for the robustness of PLS model, which also showed a significant guideline for the design and development of PLS model.
Collapse
Affiliation(s)
- Chenzhao Du
- Beijing University of Chinese Medicine, 100102 Beijing, China; Pharmaceutical Engineering and New Drug Development of Traditional Chinese Medicine (TCM) of Ministry of Education, 100102 Beijing, China; Key Laboratory of TCM-information Engineering of State Administration of TCM, 100102 Beijing, China
| | - Shengyun Dai
- Beijing University of Chinese Medicine, 100102 Beijing, China; Pharmaceutical Engineering and New Drug Development of Traditional Chinese Medicine (TCM) of Ministry of Education, 100102 Beijing, China; Key Laboratory of TCM-information Engineering of State Administration of TCM, 100102 Beijing, China
| | - Anbang Zhao
- Beijing University of Chinese Medicine, 100102 Beijing, China; Pharmaceutical Engineering and New Drug Development of Traditional Chinese Medicine (TCM) of Ministry of Education, 100102 Beijing, China; Key Laboratory of TCM-information Engineering of State Administration of TCM, 100102 Beijing, China; Traditional Chinese Medicine College of Xinjiang Medical University, 830011 Urumqi, China
| | - Yanjiang Qiao
- Beijing University of Chinese Medicine, 100102 Beijing, China; Pharmaceutical Engineering and New Drug Development of Traditional Chinese Medicine (TCM) of Ministry of Education, 100102 Beijing, China; Key Laboratory of TCM-information Engineering of State Administration of TCM, 100102 Beijing, China.
| | - Zhisheng Wu
- Beijing University of Chinese Medicine, 100102 Beijing, China; Pharmaceutical Engineering and New Drug Development of Traditional Chinese Medicine (TCM) of Ministry of Education, 100102 Beijing, China; Key Laboratory of TCM-information Engineering of State Administration of TCM, 100102 Beijing, China.
| |
Collapse
|
14
|
Mechanistic approach in powder blending PAT: Bi-layer mixing and asymptotic end point prediction. POWDER TECHNOL 2017. [DOI: 10.1016/j.powtec.2016.12.038] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
15
|
Park JB, Lee BJ, Kang CY, Repka MA. Process Analytical Quality Control of Tailored Drug Release Formulation Prepared via Hot-Melt Extrusion Technology. J Drug Deliv Sci Technol 2017; 38:51-58. [PMID: 29312469 DOI: 10.1016/j.jddst.2017.01.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The objective of the present study was to compare the influence of Eudragit® RS PO and RL PO blends on the release of water-soluble and insoluble drugs from hot-melt extruded formulations. In addition, we aimed to evaluate drug content uniformity and distribution by Fourier transform-infrared (FT-IR) chemical imaging. Theophylline (TP) and carbamazepine (CBZ) were selected as the water-soluble and insoluble model drugs, respectively. Eudragit® RS PO and RL PO were selected as the polymeric matrices. FT-IR chemical imaging clearly demonstrated the content uniformity and distribution for both drugs in the extrudates, which was confirmed by HPLC. Increasing the ratio of Eudragit® RL PO led to an increase in the in vitro drug release, whereas an increase in the ratio of Eudragit® RS PO sustained the drug release for up to 12 h. The hot-melt extrusion of TP and CBZ with varying ratios of Eudragit® RS PO and RL PO can be employed to tailor the drug release profiles. In this study, we demonstrated, for the first time, the use of FT-IR chemical imaging as a process analytical technique to determine the drug content uniformity and distribution. Our data correlated well with the results of HPLC analysis in the study of tailored drug release from the prepared hot-melt extruded formulation.
Collapse
Affiliation(s)
- Jun-Bom Park
- College of Pharmacy, Sahmyook University, Seoul, Republic of Korea
| | - Beom-Jin Lee
- College of Pharmacy, Ajou University, Suwon, Republic of Korea
| | - Chin-Yang Kang
- College of Pharmacy, Sahmyook University, Seoul, Republic of Korea
| | - Michael A Repka
- Department of Pharmaceutics & Drug Delivery, University of Mississippi, University, MS, USA.,Pii Center for Pharmaceutical Technology, School of Pharmacy, University of Mississippi, University, MS, USA
| |
Collapse
|
16
|
Fonteyne M, Vercruysse J, De Leersnyder F, Besseling R, Gerich A, Oostra W, Remon JP, Vervaet C, De Beer T. Blend uniformity evaluation during continuous mixing in a twin screw granulator by in-line NIR using a moving F-test. Anal Chim Acta 2016; 935:213-23. [PMID: 27543030 DOI: 10.1016/j.aca.2016.07.020] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 07/18/2016] [Indexed: 11/25/2022]
Abstract
This study focuses on the twin screw granulator of a continuous from-powder-to-tablet production line. Whereas powder dosing into the granulation unit is possible from a container of preblended material, a truly continuous process uses several feeders (each one dosing an individual ingredient) and relies on a continuous blending step prior to granulation. The aim of the current study was to investigate the in-line blending capacity of this twin screw granulator, equipped with conveying elements only. The feasibility of in-line NIR (SentroPAT, Sentronic GmbH, Dresden, Germany) spectroscopy for evaluating the blend uniformity of powders after the granulator was tested. Anhydrous theophylline was used as a tracer molecule and was blended with lactose monohydrate. Theophylline and lactose were both fed from a different feeder into the twin screw granulator barrel. Both homogeneous mixtures and mixing experiments with induced errors were investigated. The in-line spectroscopic analyses showed that the twin screw granulator is a useful tool for in-line blending in different conditions. The blend homogeneity was evaluated by means of a novel statistical method being the moving F-test method in which the variance between two blocks of collected NIR spectra is evaluated. The α- and β-error of the moving F-test are controlled by using the appropriate block size of spectra. The moving F-test method showed to be an appropriate calibration and maintenance free method for blend homogeneity evaluation during continuous mixing.
Collapse
Affiliation(s)
- Margot Fonteyne
- Laboratory of Pharmaceutical Process Analytical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium.
| | - Jurgen Vercruysse
- Laboratory of Pharmaceutical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium
| | - Fien De Leersnyder
- Laboratory of Pharmaceutical Process Analytical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium
| | | | | | | | - Jean Paul Remon
- Laboratory of Pharmaceutical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium
| | - Chris Vervaet
- Laboratory of Pharmaceutical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium
| | - Thomas De Beer
- Laboratory of Pharmaceutical Process Analytical Technology, Ghent University, Ottergemsesteenweg 460, Ghent, Belgium.
| |
Collapse
|
17
|
Kurhajec S, Franc A, Doležel P, Sabadková D. Quality by design approach: antioxidant activity of the tablets containing cornelian cherry fruits in relation to their composition and physical properties. Pharm Dev Technol 2016; 22:881-888. [DOI: 10.3109/10837450.2015.1135345] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Slavomír Kurhajec
- Department of Pharmaceutics, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic and
- Department of Pharmacognosy and Botany, University of Veterinary Medicine and Pharmacy, Košice, Slovakia
| | - Aleš Franc
- Department of Pharmaceutics, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic and
| | - Petr Doležel
- Department of Pharmaceutics, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic and
| | - Dana Sabadková
- Department of Pharmaceutics, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic and
| |
Collapse
|
18
|
|
19
|
Bakri B, Weimer M, Hauck G, Reich G. Assessment of powder blend uniformity: Comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging. Eur J Pharm Biopharm 2015; 97:78-89. [DOI: 10.1016/j.ejpb.2015.10.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 09/17/2015] [Accepted: 10/02/2015] [Indexed: 10/22/2022]
|
20
|
Besseling R, Damen M, Tran T, Nguyen T, van den Dries K, Oostra W, Gerich A. An efficient, maintenance free and approved method for spectroscopic control and monitoring of blend uniformity: The moving F-test. J Pharm Biomed Anal 2015; 114:471-81. [DOI: 10.1016/j.jpba.2015.06.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 06/10/2015] [Accepted: 06/14/2015] [Indexed: 10/23/2022]
|
21
|
Development of a NIR-based blend uniformity method for a drug product containing multiple structurally similar actives by using the quality by design principles. Int J Pharm 2015; 488:120-6. [DOI: 10.1016/j.ijpharm.2015.04.025] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Revised: 04/04/2015] [Accepted: 04/12/2015] [Indexed: 11/19/2022]
|
22
|
Khorasani M, Amigo JM, Bertelsen P, Van Den Berg F, Rantanen J. Detecting Blending End-Point Using Mean Squares Successive Difference Test and Near-Infrared Spectroscopy. J Pharm Sci 2015; 104:2541-9. [PMID: 26094601 DOI: 10.1002/jps.24533] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2015] [Revised: 04/30/2015] [Accepted: 05/06/2015] [Indexed: 11/08/2022]
Abstract
An algorithm based on mean squares successive difference test applied to near-infrared and principal component analysis scores was developed to monitor and determine the blending profile and to assess the end-point in the statistical stabile phase. Model formulations consisting of an active compound (acetylsalicylic acid), together with microcrystalline cellulose and two grades of calcium carbonate with dramatically different particle shapes, were prepared. The formulation comprising angular-shaped calcium carbonate reached blending end-point slower when compared with the formulation comprising equant-shaped calcium carbonate. Utilizing the ring shear test, this distinction in end-point could be related to the difference in flowability of the formulations. On the basis of the two model formulations, a design of experiments was conducted to characterize the blending process by studying the effect of CaCO3 grades and fill level of the bin on blending end-point. Calcium carbonate grades, fill level, and their interaction were shown to have a significant impact on the blending process.
Collapse
Affiliation(s)
- Milad Khorasani
- Faculty of Health and Medical Sciences, Department of Pharmacy, University of Copenhagen, Copenhagen, Denmark
| | - José M Amigo
- Faculty of Science, Department of Food Science, University of Copenhagen, Copenhagen, Denmark
| | | | - Frans Van Den Berg
- Faculty of Science, Department of Food Science, University of Copenhagen, Copenhagen, Denmark
| | - Jukka Rantanen
- Faculty of Health and Medical Sciences, Department of Pharmacy, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
23
|
Modeling strategies for pharmaceutical blend monitoring and end-point determination by near-infrared spectroscopy. Int J Pharm 2014; 473:219-31. [DOI: 10.1016/j.ijpharm.2014.06.061] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 06/06/2014] [Accepted: 06/25/2014] [Indexed: 11/21/2022]
|
24
|
Quiñones L, Velazquez C, Obregon L. A novel multiple linear multivariate NIR calibration model-based strategy for in-line monitoring of continuous mixing. AIChE J 2014. [DOI: 10.1002/aic.14498] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Leonel Quiñones
- Dept. of Chemical Engineering; University of Puerto Rico at Mayaguez; Mayaguez PR 00681
| | - Carlos Velazquez
- Dept. of Chemical Engineering; University of Puerto Rico at Mayaguez; Mayaguez PR 00681
| | - Luis Obregon
- Dept. of Chemical Engineering; Universidad del Atlántico; Barranquilla Colombia
| |
Collapse
|
25
|
Yan B, Li Y, Guo Z, Qu H. Quality by design for herbal drugs: a feedforward control strategy and an approach to define the acceptable ranges of critical quality attributes. PHYTOCHEMICAL ANALYSIS : PCA 2014; 25:59-65. [PMID: 24108478 DOI: 10.1002/pca.2463] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2013] [Revised: 06/10/2013] [Accepted: 06/15/2013] [Indexed: 06/02/2023]
Abstract
INTRODUCTION The concept of quality by design (QbD) has been widely accepted and applied in the pharmaceutical manufacturing industry. There are still two key issues to be addressed in the implementation of QbD for herbal drugs. The first issue is the quality variation of herbal raw materials and the second issue is the difficulty in defining the acceptable ranges of critical quality attributes (CQAs). OBJECTIVE To propose a feedforward control strategy and a method for defining the acceptable ranges of CQAs for the two issues. METHODS In the case study of the ethanol precipitation process of Danshen (Radix Salvia miltiorrhiza) injection, regression models linking input material attributes and process parameters to CQAs were built first and an optimisation model for calculating the best process parameters according to the input materials was established. Then, the feasible material space was defined and the acceptable ranges of CQAs for the previous process were determined. RESULTS In the case study, satisfactory regression models were built with cross-validated regression coefficients (Q(2) ) all above 91 %. The feedforward control strategy was applied successfully to compensate the quality variation of the input materials, which was able to control the CQAs in the 90-110 % ranges of the desired values. In addition, the feasible material space for the ethanol precipitation process was built successfully, which showed the acceptable ranges of the CQAs for the concentration process. CONCLUSION The proposed methodology can help to promote the implementation of QbD for herbal drugs.
Collapse
Affiliation(s)
- Binjun Yan
- Pharmaceutical Informatics Institute, Zhejiang University, Hangzhou, 310058, China
| | | | | | | |
Collapse
|
26
|
|
27
|
At-line near-infrared spectroscopy for monitoring concentrations in temperature-triggered glutamate fermentation. Bioprocess Biosyst Eng 2013; 36:1879-87. [DOI: 10.1007/s00449-013-0962-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Accepted: 04/23/2013] [Indexed: 10/26/2022]
|
28
|
In-line quantification of two active ingredients in a batch blending process by near-infrared spectroscopy: influence of physical presentation of the sample. Int J Pharm 2013; 451:67-75. [PMID: 23651640 DOI: 10.1016/j.ijpharm.2013.04.078] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Accepted: 04/22/2013] [Indexed: 11/20/2022]
Abstract
The aim of this study was to apply near-infrared (NIR) spectroscopy to the simultaneous in-line monitoring of two active pharmaceutical ingredients (APIs) in a pharmaceutical batch blending process. The formulation under study consisted of a high load API (A1), one polymer, a second API (A2) and one lubricant. Additionally, the effects of the presentation of A1 on the spectral data were evaluated. For this purpose, the high load active was blended either as a cohesive powder or as a free flowing material. For improving the flow behavior of the high load active a melt-granulation (MG) step was performed. The NIR spectra of the high load API (A1) before and after MG showed that the polymer wavelength absorption band was the most affected, this wavelength range was also associated with the water band region. Thus, these frequencies carried information from the melt-granulation process and could be influenced by the water content. For the APIs quantification, independent partial least squares (PLS-1) models for each API were generated. Furthermore, a PLS-2 model was also developed for the simultaneous quantification of each API. The PLS models were used for the in-line blend uniformity monitoring of both APIs.
Collapse
|
29
|
Matero S, van Den Berg F, Poutiainen S, Rantanen J, Pajander J. Towards better process understanding: chemometrics and multivariate measurements in manufacturing of solid dosage forms. J Pharm Sci 2013; 102:1385-403. [PMID: 23423769 DOI: 10.1002/jps.23472] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 01/22/2013] [Indexed: 01/14/2023]
Abstract
The manufacturing of tablets involves many unit operations that possess multivariate and complex characteristics. The interactions between the material characteristics and process related variation are presently not comprehensively analyzed due to univariate detection methods. As a consequence, current best practice to control a typical process is to not allow process-related factors to vary i.e. lock the production parameters. The problem related to the lack of sufficient process understanding is still there: the variation within process and material properties is an intrinsic feature and cannot be compensated for with constant process parameters. Instead, a more comprehensive approach based on the use of multivariate tools for investigating processes should be applied. In the pharmaceutical field these methods are referred to as Process Analytical Technology (PAT) tools that aim to achieve a thorough understanding and control over the production process. PAT includes the frames for measurement as well as data analyzes and controlling for in-depth understanding, leading to more consistent and safer drug products with less batch rejections. In the optimal situation, by applying these techniques, destructive end-product testing could be avoided. In this paper the most prominent multivariate data analysis measuring tools within tablet manufacturing and basic research on operations are reviewed.
Collapse
Affiliation(s)
- Sanni Matero
- Department of Food Science, Quality & Technology, Faculty of Science, University of Copenhagen, DK-1958 Frederiksberg-C, Denmark.
| | | | | | | | | |
Collapse
|
30
|
Martínez L, Peinado A, Liesum L, Betz G. Use of near-infrared spectroscopy to quantify drug content on a continuous blending process: influence of mass flow and rotation speed variations. Eur J Pharm Biopharm 2013; 84:606-15. [PMID: 23419815 DOI: 10.1016/j.ejpb.2013.01.016] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Revised: 01/23/2013] [Accepted: 01/28/2013] [Indexed: 11/15/2022]
Abstract
The aim of this study was to develop a quantitative Near-Infrared (NIR) method which monitors the homogeneity of a pharmaceutical formulation coming out of a continuous blender. For this purpose, a NIR diode array spectrometer with fast data acquisition was selected. Additionally, the dynamic aspects of a continuous blending process were studied; the results showed a well-defined cluster for the steady state, and the paths for the start-up and emptying stages were clearly identified. The end point of the start-up phase was detected by moving block of standard deviation, relative standard deviation, and principal component analysis. A partial least square (PLS) model was generated for the quantification of the drug, with a standard error of prediction of 0.2% m/m. The PLS model was successfully applied for monitoring the drug level at the outlet of the continuous blender. Furthermore, the PLS model was tested under different flow and stirring rates. Flow and stirring rate variations caused different powder flow dynamics, which were reflected on the NIR measurements. Therefore, the PLS model was sensitive to changes in mass flow and rotation speeds.
Collapse
Affiliation(s)
- Lizbeth Martínez
- Department of Pharmaceutical Sciences, Pharmacenter, University of Basel, Basel, Switzerland.
| | | | | | | |
Collapse
|
31
|
Igne B, Talwar S, Drennen JK, Anderson CA. Online Monitoring of Pharmaceutical Materials Using Multiple NIR Sensors—Part II: Blend End-point Determination. J Pharm Innov 2013. [DOI: 10.1007/s12247-012-9146-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
32
|
Qi N, Zhang Z, Xiang Y, Harrington PDB. Locally linear embedding method for dimensionality reduction of tissue sections of endometrial carcinoma by near infrared spectroscopy. Anal Chim Acta 2012; 724:12-9. [DOI: 10.1016/j.aca.2012.02.040] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2011] [Revised: 02/21/2012] [Accepted: 02/22/2012] [Indexed: 10/28/2022]
|
33
|
PAT within the QbD Framework: Real-Time End Point Detection for Powder Blends in a Compliant Environment. J Pharm Innov 2012. [DOI: 10.1007/s12247-012-9119-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
34
|
Mennini N, Furlanetto S, Cirri M, Mura P. Quality by design approach for developing chitosan-Ca-alginate microspheres for colon delivery of celecoxib-hydroxypropyl-β-cyclodextrin-PVP complex. Eur J Pharm Biopharm 2012; 80:67-75. [DOI: 10.1016/j.ejpb.2011.08.002] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Revised: 07/29/2011] [Accepted: 08/01/2011] [Indexed: 10/17/2022]
|