1
|
Tadesse GF, Geramifar P, Abbasi M, Tsegaw EM, Amin M, Salimi A, Mohammadi M, Teimourianfard B, Ay MR. Attenuation Correction for Dedicated Cardiac SPECT Imaging Without Using Transmission Data. Mol Imaging Radionucl Ther 2023; 32:42-53. [PMID: 36818953 PMCID: PMC9950684 DOI: 10.4274/mirt.galenos.2022.55476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023] Open
Abstract
Objectives Attenuation correction (AC) using transmission scanning-like computed tomography (CT) is the standard method to increase the accuracy of cardiac single-photon emission computed tomography (SPECT) images. Recently developed dedicated cardiac SPECT do not support CT, and thus, scans on these systems are vulnerable to attenuation artifacts. This study presented a new method for generating an attenuation map directly from emission data by segmentation of precisely non-rigid registration extended cardiac-torso (XCAT)-digital phantom with cardiac SPECT images. Methods In-house developed non-rigid registration algorithm automatically aligns the XCAT- phantom with cardiac SPECT image to precisely segment the contour of organs. Pre-defined attenuation coefficients for given photon energies were assigned to generate attenuation maps. The CT-based attenuation maps were used for validation with which cardiac SPECT/CT data of 38 patients were included. Segmental myocardial counts of a 17-segment model from these databases were compared based on the basis of the paired t-test. Results The mean, and standard deviation of the mean square error and structural similarity index measure of the female stress phase between the proposed attenuation maps and the CT attenuation maps were 6.99±1.23% and 92±2.0%, of the male stress were 6.87±3.8% and 96±1.0%. Proposed attenuation correction and computed tomography based attenuation correction average myocardial perfusion count was significantly higher than that in non-AC in the mid-inferior, mid-lateral, basal-inferior, and lateral regions (p<0.001). Conclusion The proposed attenuation maps showed good agreement with the CT-based attenuation map. Therefore, it is feasible to enable AC for a dedicated cardiac SPECT or SPECT standalone scanners.
Collapse
Affiliation(s)
- Getu Ferenji Tadesse
- Research Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran,Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran,St. Paul’s Hospital Millennium Medical College, Department of Internal Medicine, Addis Ababa, Ethiopia
| | - Parham Geramifar
- Tehran University of Medical Sciences, Shariati Hospital, Research Center for Nuclear Medicine, Tehran, Iran
| | - Mehrshad Abbasi
- Tehran University of Medical Sciences, Department of Nuclear Medicine, Vali-Asr Hospital, Tehran, Iran
| | - Eyachew Misganew Tsegaw
- Debre Tabor University Faculty of Natural and Computational Sciences, Department of Physics, Debre Tabor, Ethiopia
| | - Mohammad Amin
- Shahed University Faculty of Science, Department of Computer Science, Tehran, Iran
| | - Ali Salimi
- Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Mohammadi
- Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Mohammed Reza Ay
- Research Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran,Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran,* Address for Correspondence: Research Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS); Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran Phone: +989125789765 E-mail:
| |
Collapse
|
3
|
Verburg FA, Romijn RL, Nekolla S, Verzijlbergen JF. A phantom assessment of cold stomach-related artifacts in myocardial perfusion imaging. Nucl Med Commun 2009; 30:569-73. [DOI: 10.1097/mnm.0b013e32832c79ce] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|