1
|
Nagata H, Ohno Y, Yoshikawa T, Yamamoto K, Shinohara M, Ikedo M, Yui M, Matsuyama T, Takahashi T, Bando S, Furuta M, Ueda T, Ozawa Y, Toyama H. Compressed sensing with deep learning reconstruction: Improving capability of gadolinium-EOB-enhanced 3D T1WI. Magn Reson Imaging 2024; 108:67-76. [PMID: 38309378 DOI: 10.1016/j.mri.2024.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 01/20/2024] [Accepted: 01/26/2024] [Indexed: 02/05/2024]
Abstract
PURPOSE The purpose of this study was to determine the utility of compressed sensing (CS) with deep learning reconstruction (DLR) for improving spatial resolution, image quality and focal liver lesion detection on high-resolution contrast-enhanced T1-weighted imaging (HR-CE-T1WI) obtained by CS with DLR as compared with conventional CE-T1WI with parallel imaging (PI). METHODS Seventy-seven participants with focal liver lesions underwent conventional CE-T1WI with PI and HR-CE-T1WI, surgical resection, transarterial chemoembolization, and radiofrequency ablation, followed by histopathological or >2-year follow-up examinations in our hospital. Signal-to-noise ratios (SNRs) of liver, spleen and kidney were calculated for each patient, after which each SNR was compared by means of paired t-test. To compare focal lesion detection capabilities of the two methods, a 5-point visual scoring system was adopted for a per lesion basis analysis. Jackknife free-response receiver operating characteristic (JAFROC) analysis was then performed, while sensitivity and false positive rates (/data set) for consensus assessment of the two methods were also compared by using McNemar's test or the signed rank test. RESULTS Each SNR of HR-CE-T1WI was significantly higher than that of conventional CE-T1WI with PI (p < 0.05). Sensitivities for consensus assessment showed that HR-CE-MRI had significantly higher sensitivity than conventional CE-T1WI with PI (p = 0.004). Moreover, there were significantly fewer FP/cases for HR-CE-T1WI than for conventional CE-T1WI with PI (p = 0.04). CONCLUSION CS with DLR are useful for improving spatial resolution, image quality and focal liver lesion detection capability of Gd-EOB-DTPA enhanced 3D T1WI without any need for longer breath-holding time.
Collapse
Affiliation(s)
- Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Yoshiharu Ohno
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan.
| | - Takeshi Yoshikawa
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan; Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, 673-0021, Japan
| | - Kaori Yamamoto
- Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan
| | - Maiko Shinohara
- Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan
| | - Masato Ikedo
- Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan
| | - Masao Yui
- Canon Medical Systems Corporation, Otawara, Tochigi, 324-8550, Japan
| | - Takahiro Matsuyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Tomoki Takahashi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Shuji Bando
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Minami Furuta
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Takahiro Ueda
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Yoshiyuki Ozawa
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, 470-1192, Japan
| |
Collapse
|
2
|
Feasibility of Deep Learning-Based Noise and Artifact Reduction in Coronal Reformation of Contrast-Enhanced Chest Computed Tomography. J Comput Assist Tomogr 2022; 46:593-603. [PMID: 35617647 DOI: 10.1097/rct.0000000000001326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE This study aimed to evaluate the feasibility of a deep learning method for imaging artifact and noise reduction in coronal reformation of contrast-enhanced chest computed tomography (CT). METHODS A total of 19,052 coronal reformatted chest CT images of 110 CT image sets (55 pairs of concordant 16- and 320-row CT image sets) were included and used to train a deep learning algorithm for artifact and noise correction. For internal validation, 4093 coronal reformatted CT images of 25 patients from 16-row CT images underwent correction processing. For external validation, chest CT images of 30 patients (1028 coronal reformatted CT images), acquired in other institutions using different scanners, were subjected to correction processing. For both validations, image quality was compared between original ("CTorigin") and deep learning-based corrected ("CTcorrect") CT images. Quantitative analysis for stair-step artifact (coefficient of variance of CT density on coronal reformation), image noise, signal-to-noise ratio, and contrast-to-noise ratio were evaluated. Subjective image quality scores were assigned for image contrast, artifact, and conspicuity of major structures. RESULTS CTcorrect showed significantly reduced stair-step artifact (mean coefficient of variance: CTorigin 7.35 ± 2.0 vs CTcorrect 5.17 ± 2.4, P < 0.001) and image noise and improved signal-to-noise ratio and contrast-to-noise ratio in the aorta, pulmonary artery, and liver, compared with those of CTorigin (P < 0.01). On subjective analysis, CTcorrect had higher image contrast, lower artifact, and better conspicuity than CTorigin. Most results of the external validation were consistent with those obtained from the internal validation, except for those concerning the pulmonary artery. CONCLUSIONS Deep learning-based artifact correction significantly improved the image quality of coronal reformation chest CT by reducing image noise and artifacts.
Collapse
|
3
|
Ohno Y, Aoyagi K, Takenaka D, Yoshikawa T, Ikezaki A, Fujisawa Y, Murayama K, Hattori H, Toyama H. Machine learning for lung CT texture analysis: Improvement of inter-observer agreement for radiological finding classification in patients with pulmonary diseases. Eur J Radiol 2020; 134:109410. [PMID: 33246272 DOI: 10.1016/j.ejrad.2020.109410] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 10/12/2020] [Accepted: 11/06/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the capability ML-based CT texture analysis for improving interobserver agreement and accuracy of radiological finding assessment in patients with COPD, interstitial lung diseases or infectious diseases. MATERIALS AND METHODS Training cases (n = 28), validation cases (n = 17) and test cases (n = 89) who underwent thin-section CT at a 320-detector row CT with wide volume scan and two 64-detector row CTs with helical scan were enrolled in this study. From 89 CT data, a total of 350 computationally selected ROI including normal lung, emphysema, nodular lesion, ground-glass opacity, reticulation and honeycomb were evaluated by three radiologists as well as by the software. Inter-observer agreements between consensus reading with and without using the software or software alone and standard references determined by consensus of pulmonologists and chest radiologists were determined using κ statistics. Overall distinguishing accuracies were compared among all methods by McNemar's test. RESULTS Agreements for consensus readings obtained with and without the software or the software alone with standard references were determined as significant and substantial or excellent (with the software: κ = 0.91, p < 0.0001; without the software: κ = 0.81, p < 0.0001; the software alone: κ = 0.79, p < 0.0001). Overall differentiation accuracy of consensus reading using the software (94.9 [332/350] %) was significantly higher than that of consensus reading without using the software (84.3 [295/350] %, p < 0.0001) and the software alone (82.3 [288/350] %, p < 0.0001). CONCLUSION ML-based CT texture analysis software has potential for improving interobserver agreement and accuracy for radiological finding assessments in patients with COPD, interstitial lung diseases or infectious diseases.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan; Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan; Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan.
| | - Kota Aoyagi
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, Japan
| | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan; Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, Japan
| | - Aina Ikezaki
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | | | - Kazuhiro Murayama
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Hidekazu Hattori
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| |
Collapse
|
4
|
Kataria B, Nilsson Althén J, Smedby Ö, Persson A, Sökjer H, Sandborg M. Assessment of image quality in abdominal computed tomography: Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction. Eur J Radiol 2020; 122:108703. [DOI: 10.1016/j.ejrad.2019.108703] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 10/02/2019] [Accepted: 10/08/2019] [Indexed: 01/15/2023]
|
5
|
Ohno Y, Aoyagi K, Chen Q, Sugihara N, Iwasawa T, Okada F, Aoki T. Comparison of computer-aided detection (CADe) capability for pulmonary nodules among standard-, reduced- and ultra-low-dose CTs with and without hybrid type iterative reconstruction technique. Eur J Radiol 2018; 100:49-57. [PMID: 29496079 DOI: 10.1016/j.ejrad.2018.01.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 12/07/2017] [Accepted: 01/08/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE To directly compare the effect of a reconstruction algorithm on nodule detection capability of the computer-aided detection (CADe) system using standard-dose, reduced-dose and ultra-low dose chest CTs with and without adaptive iterative dose reduction 3D (AIDR 3D). MATERIALS AND METHODS Our institutional review board approved this study, and written informed consent was obtained from each patient. Standard-, reduced- and ultra-low-dose chest CTs (250 mA, 50 mA and 10 mA) were used to examine 40 patients, 21 males (mean age ± standard deviation: 63.1 ± 11.0 years) and 19 females (mean age, 65.1 ± 12.7 years), and reconstructed as 1 mm-thick sections. Detection of nodule equal to more than 4 mm in dimeter was automatically performed by our proprietary CADe software. The utility of iterative reconstruction method for improving nodule detection capability, sensitivity and false positive rate (/case) of the CADe system using all protocols were compared by means of McNemar's test or signed rank test. RESULTS Sensitivity (SE: 0.43) and false-positive rate (FPR: 7.88) of ultra-low-dose CT without AIDR 3D was significantly inferior to those of standard-dose CTs (with AIDR 3D: SE, 0.78, p < .0001, FPR, 3.05, p < .0001; and without AIDR 3D: SE, 0.80, p < .0001, FPR: 2.63, p < .0001), reduced-dose CTs (with AIDR 3D: SE, 0.81, p < .0001, FPR, 3.05, p < .0001; and without AIDR 3D: SE, 0.62, p < .0001, FPR: 2.95, p < .0001) and ultra-low-dose CT with AIDR 3D (SE, 0.79, p < .0001, FPR, 4.88, p = .0001). CONCLUSION The AIDR 3D has a significant positive effect on nodule detection capability of the CADe system even when radiation dose is reduced.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan.
| | - Kota Aoyagi
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Qi Chen
- Canon Medical Systems (China) Co., Ltd., Beijing, China
| | - Naoki Sugihara
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Tae Iwasawa
- Department of Radiology, Kanagawa Cardiovascular and Respiratory Center, Yokohama, Kanagawa, Japan
| | - Fumito Okada
- Department of Radiology, Faculty of Medicine, University of Oita, Yufu, Oita, Japan
| | - Takatoshi Aoki
- Department of Radiology, University of Occupational and Environmental Health, Kitakyushu, Fukuoka, Japan
| |
Collapse
|
6
|
Baldwin D, Callister M. What is the Optimum Screening Strategy for the Early Detection of Lung Cancer. Clin Oncol (R Coll Radiol) 2016; 28:672-681. [DOI: 10.1016/j.clon.2016.08.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 07/04/2016] [Accepted: 07/11/2016] [Indexed: 01/26/2023]
|
7
|
Callister MEJ, Baldwin DR, Akram AR, Barnard S, Cane P, Draffan J, Franks K, Gleeson F, Graham R, Malhotra P, Prokop M, Rodger K, Subesinghe M, Waller D, Woolhouse I. British Thoracic Society guidelines for the investigation and management of pulmonary nodules. Thorax 2015; 70 Suppl 2:ii1-ii54. [PMID: 26082159 DOI: 10.1136/thoraxjnl-2015-207168] [Citation(s) in RCA: 545] [Impact Index Per Article: 60.6] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- M E J Callister
- Department of Respiratory Medicine, Leeds Teaching Hospitals, Leeds, UK
| | - D R Baldwin
- Nottingham University Hospitals, Nottingham, UK
| | - A R Akram
- Royal Infirmary of Edinburgh, Edinburgh, UK
| | - S Barnard
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle, UK
| | - P Cane
- Department of Histopathology, St Thomas' Hospital, London, UK
| | - J Draffan
- University Hospital of North Tees, Stockton on Tees, UK
| | - K Franks
- Clinical Oncology, St James's Institute of Oncology, Leeds, UK
| | - F Gleeson
- Department of Radiology, Oxford University Hospitals NHS Trust, Oxford, UK
| | | | - P Malhotra
- St Helens and Knowsley Teaching Hospitals NHS Trust, UK
| | - M Prokop
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, Netherlands
| | - K Rodger
- Respiratory Medicine, St James's University Hospital, Leeds, UK
| | - M Subesinghe
- Department of Radiology, Churchill Hospital, Oxford, UK
| | - D Waller
- Department of Thoracic Surgery, Glenfield Hospital, Leicester, UK
| | - I Woolhouse
- Department of Respiratory Medicine, University Hospitals of Birmingham, Birmingham, UK
| | | | | |
Collapse
|
8
|
Iwasawa T, Matsumoto S, Aoki T, Okada F, Nishimura Y, Yamagata H, Ohno Y. A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT. Jpn J Radiol 2014; 33:76-83. [PMID: 25533196 DOI: 10.1007/s11604-014-0383-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Accepted: 12/03/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE To compare primarily viewing axial images (Axial mode) versus coronal reconstruction images (Coronal mode) in computer-aided detection (CAD) of lung nodules on multidetector computed tomography (CT) in terms of detection performance and reading time. MATERIALS AND METHODS Sixty CT data sets from two institutions were collected prospectively. Ten observers (6 radiologists, 4 pulmonologists) with varying degrees of experience interpreted the data sets using CAD as a second reader (performing nodule detection first without then with aid). The data sets were interpreted twice, once each for Axial and Coronal modes, in two sessions held 4 weeks apart. Jackknife free-response receiver-operating characteristic analysis was used to compare detection performances in the two modes. RESULTS Mean figure-of-merit values with and without aid were 0.717 and 0.684 in Axial mode and 0.702 and 0.671 in Coronal mode; use of CAD significantly increased the performance of observers in both modes (P < 0.01). Mean reading times for radiologists did not significantly differ between Axial (156 ± 74 s) and Coronal mode (164 ± 69 s; P = 0.08). Mean reading times for pulmonologists were significantly lower in Coronal (112 ± 53 s) than in Axial mode (130 ± 80 s; P < 0.01). CONCLUSION There was no statistically significant difference between Axial and Coronal modes for lung nodule detection with CAD.
Collapse
Affiliation(s)
- Tae Iwasawa
- Department of Radiology, Kanagawa Cardiovascular and Respiratory Center, 6-16-1, Tomiokahigashi, Kanazawa-ku, Yokohama, 236-0051, Japan,
| | | | | | | | | | | | | |
Collapse
|
9
|
Spears JR, Schoepf UJ, Henzler T, Joshi G, Moscariello A, Vliegenthart R, Cho YJ, Apfaltrer P, Rowe G, Weininger M, Ebersberger U. Comparison of the effect of iterative reconstruction versus filtered back projection on cardiac CT postprocessing. Acad Radiol 2014; 21:318-24. [PMID: 24360635 DOI: 10.1016/j.acra.2013.11.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 11/06/2013] [Accepted: 11/06/2013] [Indexed: 01/22/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the impact of iterative reconstruction in image space (IRIS) on image noise, image quality (IQ), and postprocessing at coronary computed tomography angiography (cCTA) compared to traditional filtered back-projection (FBP). MATERIALS AND METHODS The cCTA results of 50 patients (26 men; 58 ± 15 years, body mass index 31.5 ± 6.7 kg/m²) were investigated using a second-generation dual-source computed tomography system. Scan data were reconstructed with the use of IRIS and FBP algorithms. Two radiologists independently evaluated the reconstructions using automated coronary tree analysis software. Image noise was measured and IQ was rated on a 5-point Likert scale. The number of manual corrections after automated vessel segmentation, the time required to complete segmentation, and the number of missed segments were assessed in both IRIS and FBP reconstructions. Results were compared using paired t-test. RESULTS IRIS significantly reduced image noise compared to FBP (23.3 ± 8.8 vs. 33.5 ± 13.5 Hounsfield units, P < .001). Subjective IQ improved with IRIS (IRIS 3.2 ± 1.0 vs. FBP 3.0 ± 1.0, P < .05). IRIS decreased the time needed for coronary segmentation from 111.9 ± 40.5 seconds to 95.2 ± 38.2 seconds with FBP (P < .01) and required fewer manual corrections (5.7 ± 3.0 vs. 6.8 ± 3.6, P < .01). The number of missed vessel segments was not significantly different (3.6 ± 1.8 vs. 3.8 ± 1.9, P > .05) between IRIS and FBP, respectively. CONCLUSIONS During cCTA postprocessing, IRIS significantly decreases the time and the number of manual corrections for a complete coronary segmentation compared to FBP. This effect is likely attributable to suppression of image noise by IRIS, which improves the performance of automated vessel segmentation and positively impacts cCTA analysis.
Collapse
Affiliation(s)
- J Reid Spears
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260
| | - U Joseph Schoepf
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260.
| | - Thomas Henzler
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany
| | - Gayatri Joshi
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260
| | - Antonio Moscariello
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, "A. Gemelli" Hospital, Rome, Italy
| | - Rozemarijn Vliegenthart
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Department of Radiology, Center for Medical Imaging - North East Netherlands, University of Groningen/University Medical Center Groningen, Groningen, The Netherlands
| | - Young Jun Cho
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Department of Radiology, Konyang University College of Medicine, Daejeon, Republic of Korea
| | - Paul Apfaltrer
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany
| | - Garrett Rowe
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260
| | - Markus Weininger
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260
| | - Ullrich Ebersberger
- Heart and Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, Charleston, SC, 29425-2260; Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich, Germany
| |
Collapse
|