Hong YJ, Shim J, Lee SM, Im DJ, Hur J. Dual-Energy CT for Pulmonary Embolism: Current and Evolving Clinical Applications. Korean J Radiol 2021; 22:1555-1568. [PMID: 34448383 PMCID: PMC8390816 DOI: 10.3348/kjr.2020.1512] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 02/22/2021] [Accepted: 03/19/2021] [Indexed: 12/12/2022] Open
Abstract
Pulmonary embolism (PE) is a potentially fatal disease if the diagnosis or treatment is delayed. Currently, multidetector computed tomography (MDCT) is considered the standard imaging method for diagnosing PE. Dual-energy CT (DECT) has the advantages of MDCT and can provide functional information for patients with PE. The aim of this review is to present the potential clinical applications of DECT in PE, focusing on the diagnosis and risk stratification of PE.
Collapse
Affiliation(s)
- Yoo Jin Hong
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jina Shim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Sang Min Lee
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Dong Jin Im
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jin Hur
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
2
|
Parakh A, Lennartz S, An C, Rajiah P, Yeh BM, Simeone FJ, Sahani DV, Kambadakone AR. Dual-Energy CT Images: Pearls and Pitfalls. Radiographics 2021; 41:98-119. [PMID: 33411614 PMCID: PMC7853765 DOI: 10.1148/rg.2021200102] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/10/2020] [Accepted: 07/16/2020] [Indexed: 01/10/2023]
Abstract
Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.
Collapse
Affiliation(s)
- Anushri Parakh
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Simon Lennartz
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Chansik An
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Prabhakar Rajiah
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Benjamin M Yeh
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Frank J Simeone
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Dushyant V Sahani
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| | - Avinash R Kambadakone
- From the Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114 (A.P., S.L., F.J.S., A.R.K.); Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, Calif (C.A., B.M.Y.); Department of Radiology, Mayo Clinic, Rochester, Minn (P.R.); Department of Radiology, University of Washington, Seattle, Wash (D.V.S.); and Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany (S.L.)
| |
Collapse
|
3
|
Kosmala A, Gruschwitz P, Veldhoen S, Weng AM, Krauss B, Bley TA, Petritsch B. Dual-energy CT angiography in suspected pulmonary embolism: influence of injection protocols on image quality and perfused blood volume. Int J Cardiovasc Imaging 2020; 36:2051-2059. [PMID: 32506286 PMCID: PMC8692293 DOI: 10.1007/s10554-020-01911-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 06/02/2020] [Indexed: 12/16/2022]
Abstract
To compare intravenous contrast material (CM) injection protocols for dual-energy CT pulmonary angiography (CTPA) in patients with suspected acute pulmonary embolism with regard to image quality and pulmonary perfused blood volume (PBV) values. A total of 198 studies performed with four CM injection protocols varying in CM volume and iodine delivery rates (IDR) were retrospectively included: (A) 60 ml at 5 ml/s (IDR = 1.75gI/s), (B) 50 ml at 5 ml/s (IDR = 1.75gI/s), (C) 50 ml at 4 ml/s (IDR = 1.40gI/s), (D) 40 ml at 3 ml/s (IDR = 1.05gI/s). Image quality and PBV values at different resolution settings were compared. Pulmonary arterial tract attenuation was highest for protocol A (397 ± 110 HU; p vs. B = 0.13; vs. C = 0.02; vs. D < 0.001). CTPA image quality of protocol A was rated superior compared to protocols B and D by reader 1 (p = 0.01; < 0.001), and superior to protocols B, C and D by reader 2 (p < 0.001; 0.02; < 0.001). Otherwise, there were no significant differences in CTPA quality ratings. Subjective iodine map ratings did not vary significantly between protocols A, B, and C. Both readers rated protocol D inferior to all other protocols (p < 0.05). PBV values did not vary significantly between protocols A and B at resolution settings of 1, 4 and 10 (p = 0.10; 0.10; 0.09), while otherwise PBV values displayed a decreasing trend from protocol A to D (p < 0.05). Higher CM volume and IDR are associated with superior CTPA and iodine map quality and higher absolute PBV values.
Collapse
Affiliation(s)
- Aleksander Kosmala
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
| | - Philipp Gruschwitz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Simon Veldhoen
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Andreas Max Weng
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Bernhard Krauss
- Siemens Healthcare GmbH, Research and Development, Forchheim, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Bernhard Petritsch
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| |
Collapse
|
8
|
Kramm T, Guth S, Wiedenroth CB, Ghofrani HA, Mayer E. [Treatment of acute and chronic right ventricular failure]. Med Klin Intensivmed Notfmed 2016; 111:463-80. [PMID: 27241776 DOI: 10.1007/s00063-016-0181-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 03/17/2016] [Accepted: 04/04/2016] [Indexed: 11/28/2022]
Abstract
Acute or chronic right ventricular failure is an often misdiagnosed cause of cardiopulmonary insufficiency. In addition to clinical symptoms or laboratory testing, echocardiography and invasive hemodynamic measurement by means of right-heart catheterization are essential for diagnosis and treatment control. In case of acute right ventricular failure, adequate symptomatic treatment of the life-threatening situation is important. Main issues are maintenance of coronary artery perfusion pressure and myocardial oxygen delivery as well as reduction of right ventricular afterload. In persistent right ventricular failure extracorporeal or intracorporeal assist devices are increasingly used as bridging or destination therapy. On a long-term basis, the targeted therapy of the underlying disease is crucial.
Collapse
Affiliation(s)
- T Kramm
- Abteilung für Thoraxchirurgie, Kerckhoff Klinik gGmbH, Benekestr. 2‑8, 61231, Bad Nauheim, Deutschland.
| | - S Guth
- Abteilung für Thoraxchirurgie, Kerckhoff Klinik gGmbH, Benekestr. 2‑8, 61231, Bad Nauheim, Deutschland
| | - C B Wiedenroth
- Abteilung für Thoraxchirurgie, Kerckhoff Klinik gGmbH, Benekestr. 2‑8, 61231, Bad Nauheim, Deutschland
| | - H A Ghofrani
- Abteilung für allgemeine Pneumologie, Kerckhoff-Klinik gGmbH, Bad Nauheim, Deutschland.,Medizinische Klinik II, Mitglied des Deutschen Zentrums für Lungenforschung (DZL), Universitätsklinikum Gießen und Marburg GmbH, Gießen, Deutschland
| | - E Mayer
- Abteilung für Thoraxchirurgie, Kerckhoff Klinik gGmbH, Benekestr. 2‑8, 61231, Bad Nauheim, Deutschland
| |
Collapse
|