D'Angelo T, Mastrodicasa D, Lanzafame LRM, Yel I, Koch V, Gruenewald LD, Sharma SP, Ascenti V, Micari A, Blandino A, Vogl TJ, Mazziotti S, Budde RPJ, Booz C. Optimization of window settings for coronary arteries assessment using spectral CT-derived virtual monoenergetic imaging. LA RADIOLOGIA MEDICA 2024:10.1007/s11547-024-01835-6. [PMID: 38935247 DOI: 10.1007/s11547-024-01835-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Accepted: 06/19/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. MATERIAL AND METHODS 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. RESULTS VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p < 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. CONCLUSION Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy.
- Department of Radiology and Nuclear Medicine, Erasmus MC, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
| | - Domenico Mastrodicasa
- Department of Radiology, Stanford University School of Medicine, 453 Quarry Rd, MC 5659, Palo Alto, CA 94304-5659, USA
| | - Ludovica R M Lanzafame
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Leon D Gruenewald
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Simran P Sharma
- Department of Radiology and Nuclear Medicine, Erasmus MC, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands
| | - Velio Ascenti
- Department of Radiology, Policlinico Universitario Ospedale Maggiore, Via Francesco Sforza 35, 20122, Milan, Italy
| | - Antonino Micari
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Alfredo Blandino
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Thomas J Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| | - Silvio Mazziotti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Ricardo P J Budde
- Department of Radiology and Nuclear Medicine, Erasmus MC, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
| |
Collapse
|
2
|
Jayamani N, Pothiawala S, Ong HB, Low Choon Seng AS, Mohamed Afif A, Arumugam Z, Sung CT, Teck FC, Liang HC. Clinical audit of the image quality and customised contrast volume using P3T contrast injection software versus standard injection protocol in CT coronary angiography. Radiography (Lond) 2024; 30:1144-1150. [PMID: 38824873 DOI: 10.1016/j.radi.2024.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 04/23/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
INTRODUCTION The implications of shorter scan time and lower tube voltage in the dual-source CT coronary angiography (CTCA) scan protocol necessitate the adaptation of contrast media (CM) injection parameters. This audit evaluates the coronary arteries' vascular attenuation and image quality by comparing the personalised patient protocol technology (P3T) contrast injection software with standard injection protocol. The secondary aim is to determine the relationship between CM volume and the patient's weight. METHODOLOGY A Siemens Somatom Definition Force CT Unit was used to scan 30 sets of patients between August 2020 and October 2020. Patients were selected retrospectively and separated into Standard Injection and P3T injection protocols. An experienced radiologist blinded to the groups reviewed the coronary vessels' contrast enhancement and image quality. RESULTS Overall, the mean HU of all the main coronary artery vessels obtained from P3T injection software reached above 350 HU and was diagnostically sufficient. The mean attenuation at the proximal region of RCA in the 80-99 kg weight category was significantly higher in the P3T injection software than the standard injection protocol (p < 0.001). The CM volume proposed by P3T injection software for 40-59 kg was approximately 57 ± 5 mls, while 75 ml was used for the standard injection protocol. CONCLUSION P3T injection software in CTCA resulted in an adequate diagnostic attenuation of coronary arteries (>350HU) in all weight groups, most effectively in the higher weight group, while maintaining diagnostic image quality. Further, the P3T software reduces CM volumes in lower-weight patients. IMPLICATIONS P3T software enables reducing CM volume in lower-weight patients while improving vascular enhancement in CTCA scans in higher-weight patients.
Collapse
Affiliation(s)
- N Jayamani
- Department of Radiography, Singapore General Hospital, Singapore.
| | - S Pothiawala
- Department of Emergency Medicine, Woodlands Health, Singapore
| | - H B Ong
- Department of Radiography, Singapore General Hospital, Singapore
| | | | - A Mohamed Afif
- Department of Radiography, Singapore General Hospital, Singapore
| | - Z Arumugam
- Department of Radiography, Singapore General Hospital, Singapore
| | - C T Sung
- Department of Radiography, Singapore General Hospital, Singapore
| | - F C Teck
- Department of Radiography, Singapore General Hospital, Singapore
| | - H C Liang
- Department of Radiography, Singapore General Hospital, Singapore
| |
Collapse
|
3
|
Rengier F, Notohamiprodjo M, Weber MA. Thoughts on sustainability in the use of iodinated contrast media in CT: a practice-oriented review based on the example of a hospital and a private practice. ROFO-FORTSCHR RONTG 2024. [PMID: 38408475 DOI: 10.1055/a-2246-6697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Iodinated contrast media (CM) have become indispensable in computed tomography (CT), angiography, and cardiac cathlab as well as in other X-ray-based procedures, for example in urology. In this context, iodinated CM are released into the environment in particular via patient excretions along with other trace substances. At the same time, the use of iodinated CM also involves CM leftovers as well as packaging and consumables.In order to reduce the discharge of iodinated CM into the environment and to promote efficient use of resources, awareness of the sustainable and responsible use of iodinated CM and associated consumables is essential. A number of effective measures can contribute to this in the short, medium, and long term. Based on the literature and quantitative data from our own routine, aspects of sustainability when dealing with CM in computed tomography are discussed in this review using the example of a hospital and a private practice.When planning and performing contrast-enhanced CT examinations, personalized CM protocols can make CM use more efficient. Some CM manufacturers offer recycling programs for CM leftovers. The collection of CM excretions after CM injections using urine bags might have a major impact on reducing the discharge of iodinated CM into the environment. In addition, responsible use of consumables and packaging material, in particular the use of multi-patient systems, can make a valuable contribution to waste avoidance and resource conservation. All of these measures can ultimately be fully effective in terms of protecting the environment and resources if they can be implemented on a broad basis. For this purpose, an even greater focus on the topic of sustainability among all parties involved is desirable. · Sustainable and responsible use of iodinated contrast media is desirable.. · Various measures can be taken today to reduce the environmental impact and conserve resources.. · CM use can be made more efficient by optimizing contrast-enhanced CT examinations.. · Recycling programs for CM leftovers enable their further use.. · Urine bags might have a major impact on reducing the environmental impact..
Collapse
Affiliation(s)
- Fabian Rengier
- Pharmaceuticals Medizin, Radiology, Bayer Vital GmbH, Leverkusen, Germany
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Germany
| | - Mike Notohamiprodjo
- Radiological and Nuclear Medicine Partnership Munich (PR 1432), DIE RADIOLOGIE, Sonnenstraße 17, 80331 München, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
4
|
Xiao H, Wang X, Yang P, Wang L, Xu J. Optimization of uniformity in coronary artery enhancement using a bolus tracking technique with a dual region of interest in coronary computed tomographic angiography. Acta Radiol 2024; 65:202-210. [PMID: 38059327 DOI: 10.1177/02841851231215421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/08/2023]
Abstract
BACKGROUND Consistent coronary artery enhancement is essential to achieve accurate and reproducible quantification of coronary plaque composition. PURPOSE To optimize coronary artery uniformity of enhancement using a bolus tracking technique with a dual region of interest (ROI) in coronary computed tomography angiography (CCTA) on a 320-detector CT scanner. MATERIAL AND METHODS This prospective study recruited 100 consecutive patients who underwent CCTA and were randomly divided into two groups, namely, a manual trigger group (n = 50), in which a manual fast start technique was used to start the diagnostic scan with the visual evaluation of attenuation in the left atrium and left ventricle, and an automatic trigger group (n = 50), in which a bolus tracking technique was used to automatically start the breath-holding command and diagnostic scan with two ROIs placed in the right and left ventricles. Coronary artery image quality was assessed using quantitative and qualitative scores. The enhancement uniformity was characterized by attenuation variability of the ascending aorta (AAO) and coronary arteries. RESULTS No statistically significant differences in the image quality of the coronary arteries were observed between the two groups (all P > 0.05). The coefficients of variation (COVs) of arterial attenuation in the automatic trigger group were significantly smaller than in the manual trigger group (AAO: 9.89% vs. 17.93%; LMA: 10.35% vs. 18.98%; LAD proximal: 12.09% vs. 20.84%; LCX proximal: 11.85% vs. 20.95%; RCA proximal: 12.13% vs. 20.84%; all P < 0.05). CONCLUSION The automatic trigger technique accompanied with dual ROI provides consistent coronary artery enhancement and optimizes coronary artery enhancement uniformity in CCTA on a 320-detector CT scanner.
Collapse
Affiliation(s)
- Huawei Xiao
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Xiangquan Wang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Panfeng Yang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Ling Wang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Jian Xu
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| |
Collapse
|
5
|
Henning MK, Aaløkken TM, Martinsen AC, Johansen S. The impact of body compositions on contrast medium enhancement in chest CT: a randomised controlled trial. BJR Open 2023; 5:20230054. [PMID: 37942494 PMCID: PMC10630975 DOI: 10.1259/bjro.20230054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 09/06/2023] [Accepted: 09/11/2023] [Indexed: 11/10/2023] Open
Abstract
Objective To compare a fixed-volume contrast medium (CM) protocol with a combined total body weight (TBW) and body composition-tailored protocol in chest CT. Methods and materials Patients referred for routine contrast enhanced chest CT were prospectively categorised as normal, muscular or overweight. Patients were accordingly randomised into two groups; Group 1 received a fixed CM protocol. Group 2 received CM volume according to a body composition-tailored protocol. Objective image quality comparisons between protocols and body compositions were performed. Differences between groups and correlation were analysed using t-test and Pearson's r. Results A total of 179 patients were included: 87 in Group 1 (mean age, 51 ± 17 years); and 92 in Group 2 (mean age, 52 ± 17 years). Compared to Group 2, Group 1 showed lower vascular attenuation in muscular (mean 346 Hounsfield unit (HU) vs 396 HU; p = 0.004) and overweight categories (mean 342 HU vs 367 HU; p = 0.12), while normal category patients showed increased attenuation (385 vs 367; p = 0.61). In Group 1, strongest correlation was found between attenuation and TBW in muscular (r = -.49, p = 0.009) and waist circumference in overweight patients (r = -.50, p = 0.005). In Group 2, no significant correlations were found for the same body size parameters. In Group 1, 13% of the overweight patients was below 250 HU (p = 0.053). Conclusion A combined TBW and body composition-tailored CM protocol in chest CT resulted in more homogenous enhancement and fewer outliers compared to a fixed-volume protocol. Advances in knowledge This is, to our knowledge, the first study to investigate the impact of various body compositions on contrast medium enhancement in chest CT.
Collapse
|
6
|
Macri F, Khasanova E, Niu BT, Parakh A, Patino M, Kambadakone A, Sahani DV. Optimal Abdominal CT Image Quality in Non-Lean Patients: Customization of CM Injection Protocols and Low-Energy Acquisitions. Diagnostics (Basel) 2023; 13:2279. [PMID: 37443673 PMCID: PMC10377374 DOI: 10.3390/diagnostics13132279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 06/20/2023] [Accepted: 06/28/2023] [Indexed: 07/15/2023] Open
Abstract
We compared the image quality of abdominopelvic single-energy CT with 100 kVp (SECT-100 kVp) and dual-energy CT with 65 keV (DECT-65 keV) obtained with customized injection protocols to standard abdominopelvic CT scans (SECT-120 kVp) with fixed volumes of contrast media (CM). We retrospectively included 91 patients (mean age, 60.7 ± 15.8 years) with SECT-100 kVp and 83 (mean age, 60.3 ± 11.7 years) patients with DECT-65 keV in portovenous phase. Total body weight-based customized injection protocols were generated by a software using the following formula: patient weight (kg) × 0.40/contrast concentration (mgI/mL) × 1000. Patients had a prior abdominopelvic SECT-120 kVp with fixed injection. Iopamidol-370 was administered for all examinations. Quantitative and qualitative image quality comparisons were made between customized and fixed injection protocols. Compared to SECT-120 kVp, customized injection yielded a significant reduction in CM volume (mean difference = 9-12 mL; p ≤ 0.001) and injection rate (mean differences = 0.2-0.4 mL/s; p ≤ 0.001) in all weight categories. Improvements in attenuation, noise, signal-to-noise and contrast-to-noise ratios were observed for both SECT-100 kVp and DECT-65 keV compared to SECT-120 kVp in all weight categories (e.g., pancreas DECT-65 keV, 1.2-attenuation-fold increase vs. SECT-120 kVp; p < 0.001). Qualitative scores were ≥4 in 172 cases (98.8.4%) with customized injections and in all cases with fixed injections (100%). These findings suggest that customized CM injection protocols may substantially reduce iodine dose while yielding higher image quality in SECT-100 kVp and DECT-65 keV abdominopelvic scans compared to SECT-120 kVp using fixed CM volumes.
Collapse
Affiliation(s)
- Francesco Macri
- Department of Radiology, Geneva University Hospitals, University of Geneva, 1211 Geneva, Switzerland
| | - Elina Khasanova
- Department of Radiology, Geneva University Hospitals, University of Geneva, 1211 Geneva, Switzerland
| | - Bonnie T Niu
- Faculty of Medicine, University of Ottawa, Ottawa, ON K1N 6N5, Canada
| | - Anushri Parakh
- Department of Radiology, Abdominal Division, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Manuel Patino
- Department of Radiology, Abdominal Division, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Avinash Kambadakone
- Department of Radiology, Abdominal Division, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Dushyant V Sahani
- Department of Radiology, University of Washington, Seattle, WA 98195, USA
| |
Collapse
|
7
|
Zhang Y, Wang Y, Li J, Zhang G, Di A, Yuan H. Refining the radiation and contrast medium dose in weight-grouped scanning protocols for coronary CT angiography. J Appl Clin Med Phys 2023:e14041. [PMID: 37211752 DOI: 10.1002/acm2.14041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 04/13/2023] [Accepted: 05/03/2023] [Indexed: 05/23/2023] Open
Abstract
PURPOSE To refine the currently used, weight-grouped protocol for coronary computed tomography angiography (CCTA), in terms of the radiation and contrast medium dose, through clinical evaluation. METHODS Following the current routine setting that varies between three weight groups (group A: 55-65 kg, group B: 66-75 kg, group C: 76-85 kg), three additional reduction protocols were proposed to each group, with different combinations of lowered tube voltage (70-100 kVp), tube current (100-220 mAs), and iodine delivery rate (0.8-1.5 gI/s). A total of 321 patients scheduled for CCTA due to suspected coronary artery disease were enrolled, who were randomly assigned to one of the four subgroups of settings under the corresponding weight group. The resulting objective image quality was compared by measuring the contrast-to-noise ratio and signal-to-noise ratio. Subjective image quality was graded by two radiologists using a 4-point Likert scale, on a total of 3848 segments. The optimal protocol for each weight group was determined with respect to the image quality and the applied radiation dose. RESULTS For all three groups, no significant difference was noticed in objective images quality between subgroups of dose settings (all p > 0.05). The average score on subjective image quality was ≥3 for every subgroup, while the percentage of score 4 showed greater dependence on the setting, ranging from 83.2% to 91.5%, and was chosen to be the determining factor. The optimal dose settings were found to be 80 kVp, 150 mAs, and 1.0 gI/s for patients of 55-75 kg in weight, and 100 kVp, 170 mAs, and 1.5 gI/s for those of 76-85 kg. CONCLUSION It is feasible to refine the currently used, weight-grouped protocol for CCTA in terms of radiation and contrast medium dose, by use of an optimization strategy where the balance between dose and image quality can be improved in a routine clinical setting.
Collapse
Affiliation(s)
- Yan Zhang
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Ying Wang
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Jing Li
- United Imaging Healthcare, Shanghai, China
| | | | - Aihui Di
- Department of Radiology, Peking University Third Hospital, Beijing, China
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, Beijing, China
| |
Collapse
|
8
|
Yuan D, Wang Y, Lin S, Gutjahr R, Lyu P, Zhang Y, Gao J, Liu J. Patient-specific post-trigger delay in coronary CT angiography: A prospective study comparing with fixed delay. Eur J Radiol 2023; 163:110813. [PMID: 37043884 DOI: 10.1016/j.ejrad.2023.110813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 03/31/2023] [Accepted: 04/03/2023] [Indexed: 04/14/2023]
Abstract
OBJECTIVES To validate the peak enhancement timing of a patient-specific post-trigger delay (PTD) in Coronary CT angiography (CCTA) and compare its image quality against a fixed PTD. METHODS In this prospective study, 204 consecutive participants were randomly divided into two groups to perform CCTA in bolus tracking with either a fixed 5-second PTD (Group A) or a patient-specific PTD (Group B). Test bolus was also performed in Group B to determine the reference peak enhancement timing. One reader evaluated objective image quality, while two readers rated subjective image quality. The predicted PTD was validated through correlation and agreement analysis with the reference measurement. Objective image quality was compared between groups via two-sample t-test and linear regression, while the subjective ratings were compared with chi-square analysis. RESULTS The two groups each had 102 participants with comparable characteristics (52.9 ± 11.3 versus 52.1 ± 11.3 years of age, and 53 versus 52 males). The scan timing from patient-specific PTD demonstrated strong correlation (R = 0.77) and consistency (ICC = 0.618) with the reference peak timing. Both readers rated better subjective image quality for the Group B (p < 0.001). The mean vessel enhancement was significantly higher in Group B in all coronary vessels (all p < 0.05). After adjusting for the participant variation, the patient-specific PTD strategy was associated with an average of 33.5 HU higher enhancement compared to the fixed PTD. CONCLUSIONS Patient-specific delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality in CCTA.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yiran Wang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Shushen Lin
- Siemens Healthineers GmbH, Forchheim, Germany
| | | | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China.
| |
Collapse
|
9
|
Soschynski M, Hagar MT, Taron J, Krauss T, Ruile P, Hein M, Nührenberg T, Russe MF, Bamberg F, Schlett CL. Update for the Performance of CT Coronary Angiography. ROFO-FORTSCHR RONTG 2022; 194:613-624. [PMID: 35231938 DOI: 10.1055/a-1747-3554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Coronary CT angiography (cCTA) is a class 1 recommendation in the current guidelines by the European Society of Cardiology (ESC) for excluding significant coronary artery stenosis. To achieve optimal image quality at a low radiation dose, the imaging physician may choose different acquisition modes. Therefore, the consensus guidelines by the Society of Cardiovascular Computed Tomography (SCCT) provide helpful guidance for this procedure. METHOD The article provides practical recommendations for the application and acquisition of cCTA based on the current literature and our own experience. RESULTS AND CONCLUSION According to current ESC guidelines, cCTA is recommended in symptomatic patients with a low or intermediate clinical likelihood for coronary artery disease. We recommend premedication with beta blockers and nitrates prior to CT acquisition under certain conditions even with the latest CT scanner generations. The most current CT scanners offer three possible scan modes for cCTA acquisition. Heart rate is the main factor for selecting the scan mode. Other factors may be coronary calcifications and body mass index (BMI). KEY POINTS · CCTA is a valid method to exclude coronary artery disease in patients with a low to intermediate clinical likelihood.. · Even with the latest generation CT scanners, premedication with beta blockers and nitrates can improve image quality at low radiation exposure.. · Current CT scanners usually provide retrospective ECG gating and prospective ECG triggering. Dual-source scanners additionally provide a "high pitch" scan mode to scan the whole heart during one heartbeat, which may also be achieved using single-source scanners with broad detectors in some cases.. · Besides the available scanner technology, the choice of scan mode primarily depends on heart rate and heart rate variability (e. g., arrhythmia).. CITATION FORMAT · Soschynski M, Hagar MT, Taron J et al. Update for the Performance of CT Coronary Angiography. Fortschr Röntgenstr 2022; DOI: 10.1055/a-1747-3554.
Collapse
Affiliation(s)
- Martin Soschynski
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Muhammad Taha Hagar
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Jana Taron
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany.,Cardiac MR PET CT Program, Massachusetts General-Hospital, Harvard Medical School, Boston, United States
| | - Tobias Krauss
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Philipp Ruile
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Manuel Hein
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Thomas Nührenberg
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Christopher L Schlett
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| |
Collapse
|
10
|
Henning MK, Aaløkken TM, Johansen S. Contrast medium protocols in routine chest CT: a survey study. Acta Radiol 2022; 63:351-359. [PMID: 33648351 DOI: 10.1177/0284185121997111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Administration of contrast medium (CM) is an important image quality factor in computed tomography (CT) of the chest. There is no clear evidence or guidelines on CM strategies for chest CT, thus a consensus approach is needed. PURPOSE To survey the potential impact on differences in chest CT protocols, with emphasis on strategies for the administration of CM. MATERIAL AND METHODS A total of 170 respondents were included in this survey, which used two different approaches: (i) an online survey was sent to the members of the European Society of Thoracic Imaging (ESTI); and (ii) an email requesting a copy of their CT protocol was sent to all hospitals in Norway, and university hospitals in Sweden and Denmark. The survey focused on factors affecting CM protocols and enhancement in chest CT. RESULTS The overall response rate was 24% (n = 170): 76% of the respondents used a CM concentration of ≥350 mgI/mL; 52% of the respondents used a fixed CM volume strategy. Fixed strategies for injection rate and delay were also the most common approach, practiced by 73% and 57% of the respondents, respectively. The fixed delay was in the range of 20-90 s. Of the respondents, 56% used flexible tube potential strategies (kV). CONCLUSION The chest CT protocols and CM administration strategies employed by the respondents vary widely, affecting the image quality. The results of this study underline the need for further research and consensus guidelines related to chest CT.
Collapse
Affiliation(s)
- Mette Karen Henning
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Trond Mogens Aaløkken
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
- Faulty of Medicine, University of Oslo, Oslo, Norway
| | - Safora Johansen
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
11
|
van den Boogert TPW, Lopes RR, Lobe NHJ, Verwest TA, Stoker J, Henriques JP, Marquering HA, Planken RN. Patient-tailored Contrast Delivery Protocols for Computed Tomography Coronary Angiography: Lower Contrast Dose and Better Image Quality. J Thorac Imaging 2021; 36:353-359. [PMID: 34269752 DOI: 10.1097/rti.0000000000000593] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The first objective of this study was to evaluate the efficacy of a patient-tailored contrast delivery protocol for coronary computed tomography angiography (CTCA), in terms of diagnostic coronary attenuation and total iodine load (TIL), by adjusting the iodine delivery rate (IDR) via dilution for body weight and tube voltage (kV), as compared with a protocol with a fixed bolus of contrast in a clinical setting. The secondary objective was to assess the association between the test-bolus data and luminal attenuation in CTCA. MATERIALS AND METHODS Patients who underwent CTCA with fixed IDR contrast delivery (cohort 1) or with IDR adjusted for body weight and kV settings (70 to 120 kV) (cohort 2) were included, and compared for intravascular luminal attenuation and TIL. The association between intravascular luminal attenuation and test-bolus scan data was investigated with linear regression. RESULTS In cohort 1 (176 patients), the mean luminal attenuation differed markedly between kV categories, whereas in cohort 2 (154 patients), there were no marked differences. The mean TIL reduced significantly (20.1±1.2 g in cohort 1, 17.7±3.0 g in cohort 2, P<0.001). The peak height of the test-bolus scan was independently associated with luminal attenuation in the ascending aorta, with a 0.58 HU increase per HU peak-height increase (SE=0.18, P<0.001). CONCLUSION Clinical implementation of a patient-tailored contrast delivery protocol for CTCA, adjusted for body weight and kV, improves luminal attenuation and significantly reduces the TIL. The peak height of the test-bolus scan is associated with luminal attenuation in the ascending aorta in the CTCA scan.
Collapse
Affiliation(s)
| | | | - Nick H J Lobe
- Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Cardiovascular Sciences
| | - Tim A Verwest
- Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Cardiovascular Sciences
| | - Jaap Stoker
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam, The Netherlands
| | | | - Henk A Marquering
- Biomedical Engineering and Physics
- Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Cardiovascular Sciences
| | - R Nils Planken
- Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Cardiovascular Sciences
| |
Collapse
|
12
|
de Jong DJ, Veldhuis WB, Wessels FJ, de Vos B, Moeskops P, Kok M. Towards Personalised Contrast Injection: Artificial-Intelligence-Derived Body Composition and Liver Enhancement in Computed Tomography. J Pers Med 2021; 11:jpm11030159. [PMID: 33668286 PMCID: PMC7996171 DOI: 10.3390/jpm11030159] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 12/11/2022] Open
Abstract
In contrast-enhanced computed tomography, total body weight adapted contrast injection protocols have proven successful in achieving a homogeneous enhancement of vascular structures and liver parenchyma. However, because solid organs have greater perfusion than adipose tissue, the lean body weight (fat-free mass) rather than the total body weight is theorised to cause even more homogeneous enhancement. We included 102 consecutive patients who underwent a multiphase abdominal computed tomography between March 2016 and October 2019. Patients received contrast media (300 mgI/mL) according to bodyweight categories. Using regions of interest, we measured the Hounsfield unit (HU) increase in liver attenuation from unenhanced to contrast-enhanced computed tomography. Furthermore, subjective image quality was graded using a four-point Likert scale. An artificial intelligence algorithm automatically segmented and determined the body compositions and calculated the percentages of lean body weight. The hepatic enhancements were adjusted for iodine dose and iodine dose per total body weight, as well as percentage lean body weight. The associations between enhancement and total body weight, body mass index, and lean body weight were analysed using linear regression. Patients had a median age of 68 years (IQR: 58–74), a total body weight of 81 kg (IQR: 73–90), a body mass index of 26 kg/m2 (SD: ±4.2), and a lean body weight percentage of 50% (IQR: 36–55). Mean liver enhancements in the portal venous phase were 61 ± 12 HU (≤70 kg), 53 ± 10 HU (70–90 kg), and 53 ± 7 HU (≥90 kg). The majority (93%) of scans were rated as good or excellent. Regression analysis showed significant correlations between liver enhancement corrected for injected total iodine and total body weight (r = 0.53; p < 0.001) and between liver enhancement corrected for lean body weight and the percentage of lean body weight (r = 0.73; p < 0.001). Most benefits from personalising iodine injection using %LBW additive to total body weight would be achieved in patients under 90 kg. Liver enhancement is more strongly associated with the percentage of lean body weight than with the total body weight or body mass index. The observed variation in liver enhancement might be reduced by a personalised injection based on the artificial-intelligence-determined percentage of lean body weight.
Collapse
Affiliation(s)
- Daan J. de Jong
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Wouter B. Veldhuis
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Frank J. Wessels
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
| | - Bob de Vos
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Pim Moeskops
- Quantib-U, Padualaan 8, 3584 CH Utrecht, The Netherlands; (B.d.V.); (P.M.)
| | - Madeleine Kok
- Department of Radiology, University Medical Center Utrecht, Heilberglaan 100, 3584 CX Utrecht, The Netherlands; (D.J.d.J.); (W.B.V.); (F.J.W.)
- Correspondence: ; Tel.: +31-88-75555-55
| |
Collapse
|
13
|
Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners. Sci Rep 2020; 10:16690. [PMID: 33028924 PMCID: PMC7541528 DOI: 10.1038/s41598-020-73915-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Accepted: 04/21/2020] [Indexed: 11/08/2022] Open
Abstract
We evaluated the feasibility and image quality of prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (CCTA) using a body surface area (BSA) protocol for contrast-medium (CM) administration on both second- and third-generation scanners (Flash and Force CT), without using heart rate control. One-hundred-and-eighty patients with suspected coronary heart disease undergoing CCTA were divided into groups A (BSA protocol for CM on Flash CT), B (body mass index (BMI)-matched patients; BMI protocol for CM on Flash CT), and C (BMI-matched patients; BSA protocol for CM on Force CT). Patient characteristics, quantitative and qualitative measures, and radiation dose were compared between groups A and B, and A and C. Of the 180 patients, 99 were male (median age, 62 years). Average BSA in groups A, B, and C was 1.80 ± 0.17 m2, 1.74 ± 0.16 m2, and 1.64 ± 0.17 m2, respectively, with groups A and C differing significantly (P < 0.001). Contrast volume (50.50 ± 8.57 mL vs. 45.00 ± 6.18 mL) and injection rate (3.90 ± 0.44 mL/s vs. 3.63 ± 0.22 mL/s) differed significantly between groups A and C (P < 0.001). Groups A and C (both: all CT values > 250 HU, average scores > 4) achieved slightly lower diagnostic image quality than group B. The BSA protocol for CM administration was feasible in both Flash and Force CT, and therefore may be valuable in clinical practice.
Collapse
|
14
|
Evaluation of a Tube Voltage-Tailored Contrast Medium Injection Protocol for Coronary CT Angiography: Results From the Prospective VOLCANIC Study. AJR Am J Roentgenol 2020; 215:1049-1056. [PMID: 32960669 DOI: 10.2214/ajr.20.22777] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE. The purpose of this study was to prospectively evaluate, using software support, the feasibility and the quantitative and qualitative image quality parameters of a tube voltage-tailored contrast medium (CM) application protocol for patient-specific injection during coronary CT angiography (CCTA). SUBJECTS AND METHODS. In the Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography (VOLCANIC-CTA) study, a single-center trial, 120 patients referred for CCTA were prospectively assigned to a tube voltage-tailored CM injection protocol. Automated tube voltage levels were selected in 10-kV intervals and ranged from 70 to 130 kV, and the iodine delivery rate (IDR) was adapted to the tube voltage level using dedicated software. The administered CM volume (370 mg I/mL) ranged from 33 mL at 70 kV (IDR, 0.7 g I/s) to 65 mL at 130 kV (IDR, 1.7 g I/s). Attenuation was measured in the aorta and coronary arteries to calculate quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and 5-point scales were used to evaluate overall image quality. Radiation metrics were also assessed and compared among the protocols. RESULTS. The mean age of the study patients was 62.5 ± 11.9 (SD) years. Image quality was rated as diagnostic in all patients. Contrast attenuation peaked at 70 kV (p < 0.001), whereas SNR and CNR parameters showed no significant differences between tube voltage levels (p ≥ 0.085). Additionally, no significant differences in subjective image quality parameters were found among the different protocols (p ≥ 0.139). The lowest radiation dose values were observed in the group assigned to the 70-kV protocol, which had a median radiation effective dose of 2.0 mSv (p < 0.001). CONCLUSION. The proposed tube voltage-tailored injection protocol allows individualized scanning of patients undergoing CCTA and significantly reduces CM and radiation dose while maintaining a high diagnostic image quality.
Collapse
|
15
|
Tailoring Contrast Media Protocols to Varying Tube Voltages in Vascular and Parenchymal CT Imaging: The 10-to-10 Rule. Invest Radiol 2020; 55:673-676. [PMID: 32898358 DOI: 10.1097/rli.0000000000000682] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The latest technical developments in CT have created the possibility for individualized scan protocols at variable kV settings. Lowering tube voltages closer to the K-edge of iodine increases attenuation. However, the latter is also influenced by patient characteristics such as total body weight. To maintain a robust contrast enhancement throughout the patient population in both vascular and parenchymal CT scans, one must adapt the contrast media administration protocols to both the selected kV setting and patient body habitus. This article proposes a simple rule of thumb for how to adapt the contrast media protocol to any kV setting: the 10-to-10 rule.
Collapse
|
16
|
Dastan K, Henning MK, England A, Aalokken TM, Johansen S. An investigation into the variability of radiographers assessing body composition prior to CT contrast media administration. Radiography (Lond) 2020; 27:168-172. [PMID: 32855023 DOI: 10.1016/j.radi.2020.07.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/29/2020] [Accepted: 07/15/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION To evaluate and report the variability of radiographers in determining a patient's body type and using this to determine contrast media (CM) volumes for chest computed tomography (CT). METHODS This prospective study recruited 50 patients undergoing chest CT examinations. Three radiographers independently used two methods to determine patient body type and consequently CM volume. In Method 1, subjective evaluation of body type together with patient weight determined CM volume. In Method 2, patient weight along with additional criteria applied by the radiographer determined CM volume. Both the determination of body type and CM volumes were compared in terms of agreement and variability between radiographers, and between methods. RESULTS Fleiss' kappa was lower (0.583) for Method 1 when compared to Method 2 (0.926) indicating stronger agreement in the radiographer determination of body type for Method 2. Median (IQR) CM volume was 95.0 mL (85.0-110.0) for Method 1, compared to 92.5 mL (85.0-100.0) for method 2 (P < 0.001). CONCLUSION Method 2 provided greater agreement in determination of body type, and reduction of CM volumes compared to Method 1. IMPLICATIONS FOR PRACTICE Determining body type as part of a CT CM strategy can be subjective and enhanced methods are required to ensure that the most appropriate CM volumes are reliably used.
Collapse
Affiliation(s)
- K Dastan
- Directorate of Radiography, University of Salford, Salford, UK
| | - M K Henning
- Oslo University Hospital, Diagnostic and Nuclear Medicine Department, Oslo, Norway
| | - A England
- School of Allied Health Professions, Keele University, Staffordshire, UK
| | - T M Aalokken
- Oslo University Hospital, Diagnostic and Nuclear Medicine Department, Oslo, Norway; University of Oslo, Medicine Faculty, Oslo, Norway
| | - S Johansen
- Oslo Metropolitan University, Oslo, Norway; Oslo University Hospital, Cancer Treatment Department, Oslo, Norway.
| |
Collapse
|
17
|
Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial). CONTRAST MEDIA & MOLECULAR IMAGING 2020; 2020:5407936. [PMID: 32410922 PMCID: PMC7201621 DOI: 10.1155/2020/5407936] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 11/22/2019] [Indexed: 02/04/2023]
Abstract
Aim To evaluate the performance of three contrast media (CM) injection protocols for cardiac computed tomography angiography (CCTA) based on body weight (BW), lean BW (LBW), and cardiac output (CO). Materials and methods. A total of 327 consecutive patients referred for CCTA were randomized into one of the three CM injection protocols, where CM injection was based on either BW (112 patients), LBW (108 patients), or CO (107 patients). LBW and CO were calculated via formulas. All scans were ECG-gated and performed on a third-generation dual-source CT with 70-120 kV (automated tube voltage selection) and 100 kVqual.ref/330 mAsqual.ref. CM injection protocols were also adapted to scan time and tube voltage. The primary outcome was the proportion of patients with optimal intravascular attenuation (325-500 HU). Secondary outcomes were mean and standard deviation of intravascular attenuation values (HU), contrast-to-noise ratio (CNR), and subjective image quality with a 4-point Likert scale (1 = poor/2 = sufficient/3 = good/4 = excellent). The t-test for independent samples was used for pairwise comparisons between groups, and a chi-square test (χ2) was used to compare categorical variables between groups. All p values were 2-sided, and a p < 0.05 was considered statistically significant. Results Mean overall HU and CNR were 423 ± 60HU/14 ± 3 (BW), 404 ± 62HU/14 ± 3 (LBW), and 413 ± 63HU/14 ± 3 (CO) with a significant difference between groups BW and LBW (p=0.024). The proportion of patients with optimal intravascular attenuation (325-500 HU) was 83.9%, 84.3%, and 86.9% for groups BW, LBW, and CO, respectively, and between-group differences were small and nonsignificant. Mean CNR was diagnostic (≥10) in all groups. The proportion of scans with good-excellent image quality was 94.6%, 86.1%, and 90.7% in the BW, LBW, and CO groups, respectively. The difference between proportions was significant between the BW and LBW groups. Conclusion Personalization of CM injection protocols based on BW, LBW, and CO, and scan time and tube voltage in CCTA resulted in low variation between patients in terms of intravascular attenuation and a high proportion of scans with an optimal intravascular attenuation. The results suggest that personalized CM injection protocols based on LBW or CO have no additional benefit when compared with CM injection protocols based on BW.
Collapse
|
18
|
El Merhi F, Bou-Fakhredin R, El Ashkar B, Ghieh D, Ghosn Y, Saade C. State of the art of coronary computed tomography angiography. Radiography (Lond) 2020; 26:174-182. [PMID: 32052781 DOI: 10.1016/j.radi.2019.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 09/21/2019] [Accepted: 10/02/2019] [Indexed: 01/07/2023]
Abstract
OBJECTIVES The aim of this paper is to evaluate contrast media (CM) bolus geometry and opacification patterns in the coronary arteries with particular focus on patient, scanner and safety considerations during coronary computed tomography angiography (CCTA). KEY FINDINGS The rapid evolution of computed tomography (CT) technology has seen this imaging modality challenge conventional coronary angiography in the evaluation of coronary artery disease. Increases in spatial and temporal resolutions have enabled CCTA to become the modality of choice when evaluating the coronary vascular tree as an alternative in the diagnostic algorithm for acute chest pain. However, these new technologic improvements in scanner technology have imposed new challenges for the optimisation of CM delivery and image acquisition strategies. CONCLUSION Understanding basic CM-imaging principles is essential for designing optimal injection protocols according to each specific clinical scenario, independently of scanner technology. IMPLICATIONS FOR PRACTICE With rapid advances in CT scanner technology including faster scan acquisitions, the risk of poor opacification of coronary vasculature increases significantly. Therefore, awareness of CM delivery protocols is paramount to consistently provide optimal image quality at a low radiation dose.
Collapse
Affiliation(s)
- F El Merhi
- Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| | - R Bou-Fakhredin
- American University of Beirut, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| | - B El Ashkar
- Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| | - D Ghieh
- Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| | - Y Ghosn
- Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| | - C Saade
- Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut, 1107 2020, Lebanon.
| |
Collapse
|
19
|
Individually Body Weight-Adapted Contrast Media Application in Computed Tomography Imaging of the Liver at 90 kVp. Invest Radiol 2019; 54:177-182. [PMID: 30721159 DOI: 10.1097/rli.0000000000000525] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES The aim of the present study was to evaluate the attenuation and image quality (IQ) of a body weight-adapted contrast media (CM) protocol compared with a fixed injection protocol in computed tomography (CT) of the liver at 90 kV. MATERIALS AND METHODS One hundred ninety-nine consecutive patients referred for abdominal CT imaging in portal venous phase were included. Group 1 (n = 100) received a fixed CM dose with a total iodine load (TIL) of 33 g I at a flow rate of 3.5 mL/s, resulting in an iodine delivery rate (IDR) of 1.05 g I/s. Group 2 (n = 99) received a body weight-adapted CM protocol with a dosing factor of 0.4 g I/kg with a subsequent TIL adapted to the patients' weight. Injection time of 30 seconds was kept identical for all patients. Therefore, flow rate and IDR changed with different body weight. Patients were divided into 3 weight categories; 70 kg or less, 71 to 85 kg, and 86 kg or greater. Attenuation (HU) in 3 segments of the liver, signal-to-noise ratio, and contrast-to-noise ratio were used to evaluate objective IQ. Subjective IQ was assessed by a 5-point Likert scale. Differences between groups were statistically analyzed (P < 0.05 was considered statistically significant). RESULTS No significant differences in baseline characteristics were found between groups. The CM volume and TIL differed significantly between groups (P < 0.01), with mean values in group 1 of 110 mL and 33 g I, and in group 2 of 104.1 ± 21.2 mL and 31.2 ± 6.3 g I, respectively. Flow rate and IDR were not significantly different between groups (P > 0.05). Body weight-adapted protocoling led to more homogeneous enhancement of the liver parenchyma compared with a fixed protocol with a mean enhancement per weight category in group 2 of 126.5 ± 15.8, 128.2 ± 15.3, and 122.7 ± 21.2 HU compared with that in group 1 of 139.9 ± 21.4, 124.6 ± 24.8, and 116.2 ± 17.8 HU, respectively. CONCLUSIONS Body weight-adapted CM injection protocols result in more homogeneous enhancement of the liver parenchyma at 90 kV in comparison to a fixed CM volume with comparable objective and subjective IQ, whereas overall CM volume can be safely reduced in more than half of patients.
Collapse
|
20
|
Onoda H, Ueno H, Hashimoto M, Kuwahara H, Sobajima M, Kinugawa K. Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic Angiography Before Transcatheter Aortic Valve Implantation. Int Heart J 2019; 60:1091-1097. [PMID: 31484865 DOI: 10.1536/ihj.18-693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Low-voltage computed tomographic angiography (CTA) is a highly effective technique to reduce contrast media volume. We sought to examine the suitability of low tube voltage CTA with a reduced contrast media volume protocol using third-generation 192-slice dual-source CT in patients undergoing transcatheter aortic valve implantation (TAVI). CTA was performed to aid TAVI planning for 40 consecutive patients with severe aortic stenosis. For the first 10 patients (120/100 kV group), we used a conventional tube voltage combined CTA protocol (an ECG-gated helical scan; 120 kV, non-gated helical scan; 100 kV). For the subsequent 30 patients (70-kV group), we adopted a low tube voltage CTA protocol. We evaluated vascular attenuation, image noise, contrast-to-noise ratio (CNR), and renal function. The mean contrast media (CM) volume was 77.7 ± 17.7 mL in the 120/100-kV group and 30.9 ± 6.3 mL in the 70-kV group (P < 0.001). In the images of the aortic valve complex, the mean attenuation was not significant difference for both groups. In the images of the aorto-femoral arteries, mean attenuation was > 250 Hounsfield Units and CNR was > 10 in all vascular segments for both groups. There was no significant difference in the change of renal function in the 70-kV group, but renal function in the 120/100-kV group decreased within 1-3 months after CTA. Low tube voltage CTA using third-generation dual-source CT is suitable to assess procedural planning for TAVI. This approach maintains image quality and reduces the required CM volume.
Collapse
Affiliation(s)
- Hiroshi Onoda
- Second Department of Internal Medicine, University of Toyama
| | - Hiroshi Ueno
- Second Department of Internal Medicine, University of Toyama
| | | | | | - Mitsuo Sobajima
- Second Department of Internal Medicine, University of Toyama
| | | |
Collapse
|
21
|
Effect of tube potential and luminal contrast attenuation on atherosclerotic plaque attenuation by coronary CT angiography: In vivo comparison with intravascular ultrasound. J Cardiovasc Comput Tomogr 2019; 13:219-225. [DOI: 10.1016/j.jcct.2019.02.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 11/08/2018] [Indexed: 12/26/2022]
|
22
|
Shan QY, Hu HT, Feng ST, Peng ZP, Chen SL, Zhou Q, Li X, Xie XY, Lu MD, Wang W, Kuang M. CT-based peritumoral radiomics signatures to predict early recurrence in hepatocellular carcinoma after curative tumor resection or ablation. Cancer Imaging 2019; 19:11. [PMID: 30813956 PMCID: PMC6391838 DOI: 10.1186/s40644-019-0197-5] [Citation(s) in RCA: 109] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Accepted: 02/17/2019] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE To construct a prediction model based on peritumoral radiomics signatures from CT images and investigate its efficiency in predicting early recurrence (ER) of hepatocellular carcinoma (HCC) after curative treatment. MATERIALS AND METHODS In total, 156 patients with primary HCC were randomly divided into the training cohort (109 patients) and the validation cohort (47 patients). From the pretreatment CT images, we extracted 3-phase two-dimensional images from the largest cross-sectional area of the tumor. A region of interest (ROI) was manually delineated around the lesion for tumoral radiomics (T-RO) feature extraction, and another ROI was outlined with an additional 2 cm peritumoral area for peritumoral radiomics (PT-RO) feature extraction. The least absolute shrinkage and selection operator (LASSO) logistic regression model was applied for feature selection and model construction. The T-RO and PT-RO models were constructed. In the validation cohort, the prediction efficiencies of the two models and peritumoral enhancement (PT-E) were evaluated qualitatively by receiver operating characteristic (ROC) curves, calibration curves and decision curves and quantitatively by area under the curve (AUC), the category-free net reclassification index (cfNRI) and integrated discrimination improvement values (IDI). RESULTS By comparing AUC values, the prediction accuracy in the validation cohort was good for the PT-RO model (0.80 vs. 0.79, P = 0.47) but poor for the T-RO model (0.82 vs. 0.62, P < 0.01), which was significantly overfitted. In the validation cohort, the ROC curves, calibration curves and decision curves indicated that the PT-RO model had better calibration efficiency and provided greater clinical benefits. CfNRI indicated that the PT-RO model correctly reclassified 47% of ER patients and 32% of non-ER patients compared to the T-RO model (P < 0.01); additionally, the PT-RO model correctly reclassified 24% of ER patients and 41% of non-ER patients compared to PT-E (P = 0.02). IDI indicated that the PT-RO model could improve prediction accuracy by 0.22 (P < 0.01) compared to the T-RO model and by 0.20 (P = 0.01) compared to PT-E. CONCLUSION The CT-based PT-RO model can effectively predict the ER of HCC and is more efficient than the T-RO model and the conventional imaging feature PT-E.
Collapse
Affiliation(s)
- Quan-Yuan Shan
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Hang-Tong Hu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Shi-Ting Feng
- Department of Radiology, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Zhen-Peng Peng
- Department of Radiology, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Shu-Ling Chen
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Qian Zhou
- Clinical Trials Unit, the First Affiliated Hospital of Sun Yat-sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Xin Li
- GE Healthcare, Shanghai, China
| | - Xiao-Yan Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Ming-de Lu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China.,Department of Liver Surgery, Division of Interventional Ultrasound, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China
| | - Wei Wang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China.
| | - Ming Kuang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, Ultrasomics Artificial Intelligence X-Lab, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China. .,Department of Liver Surgery, Division of Interventional Ultrasound, the First Affiliated Hospital of Sun Yat-Sen University, 58 Zhong Shan Road 2, Guangzhou, 510080, China.
| |
Collapse
|
23
|
Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA. PLoS One 2018; 13:e0203682. [PMID: 30256835 PMCID: PMC6157854 DOI: 10.1371/journal.pone.0203682] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 08/25/2018] [Indexed: 12/27/2022] Open
Abstract
Purpose The aim was to assess personalised contrast media (CM) protocols—based on patient’s blood volume (BV) and automated tube voltage selection (ATVS)—in coronary computed tomography angiography (CCTA). Methods A total of 114 consecutive patients received an ECG-triggered or ECG-gated helical scan on a 3rd-generation dual-source CT with 70-120kV (ATVS) and 330mAsqual.ref. CM was adapted to BV, scan time (s) and kV. Image quality (IQ) was assessed in a 17-segment coronary model using attenuation values (HU), contrast-to-noise (CNR), signal-to-noise ratio (SNR) (objective IQ) and a Likert scale (subjective IQ: 1 = poor/2 = sufficient/3 = good/4 = excellent). ig Results Patient distribution was: n = 60 for 70kV, n = 37 80kV and n = 17 90kV. Mean BV was 5.4±0.6L for men and 4.1±0.6L for women. Mean CM volume (300 mg I/mL) and flow rate were: 30.9±6.4mL and 3.3±0.5mL/s (70kV); 40.8±7.1mL and 4.5±0.6mL/s (80kV); 53.6±8.6mL and 5.7±0.6mL/s (90kV). Overall mean HU was >300HU in 98.2% (112/114) of patients. Overall mean attenuation was below 300HU in two scans (70kV) due to late scan timing. Of 1.661 segments, 95.4% was assessable. Mean CNR was 14±4(70kV), 13±3(80kV) and 14±4(90kV); mean SNR was 10±2(both 70kV+80kV) and 9±2(90kV). Objective IQ was comparable between kV settings, protocols and sex. Subjective IQ was diagnostic in all scans and excellent-sufficient in 95.4% of segments. Conclusions Personalisation of CCTA CM injection protocols to BV and ATVS is a promising technique to tailor CM administration to the individual patient, while maintaining diagnostic IQ.
Collapse
|
24
|
Visualisation of coronary venous anatomy by computed tomography angiography prior to cardiac resynchronisation therapy implantation. Neth Heart J 2018; 26:433-444. [PMID: 30030750 PMCID: PMC6115304 DOI: 10.1007/s12471-018-1132-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND The purpose of this study was to illustrate the additive value of computed tomography angiography (CTA) for visualisation of the coronary venous anatomy prior to cardiac resynchronisation therapy (CRT) implantation. METHODS Eighteen patients planned for CRT implantation were prospectively included. A specific CTA protocol designed for visualisation of the coronary veins was carried out on a third-generation dual-source CT platform. Coronary veins were semi-automatically segmented to construct a 3D model. CTA-derived coronary venous anatomy was compared with intra-procedural fluoroscopic angiography (FA) in right and left anterior oblique views. RESULTS Coronary venous CTA was successfully performed in all 18 patients. CRT implantation and FA were performed in 15 patients. A total of 62 veins were visualised; the number of veins per patient was 3.8 (range: 2-5). Eighty-five per cent (53/62) of the veins were visualised on both CTA and FA, while 10% (6/62) were visualised on CTA only, and 5% (3/62) on FA only. Twenty-two veins were present on the lateral or inferolateral wall; of these, 95% (21/22) were visualised by CTA. A left-sided implantation was performed in 13 patients, while a right-sided implantation was performed in the remaining 2 patients because of a persistent left-sided superior vena cava with no left innominate vein on CTA. CONCLUSION Imaging of the coronary veins by CTA using a designated protocol is technically feasible and facilitates the CRT implantation approach, potentially improving the outcome.
Collapse
|
25
|
Feng R, Tong J, Liu X, Zhao Y, Zhang L. High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium. Korean J Radiol 2017; 18:763-772. [PMID: 28860894 PMCID: PMC5552460 DOI: 10.3348/kjr.2017.18.5.763] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2016] [Accepted: 02/22/2017] [Indexed: 11/15/2022] Open
Abstract
Objective To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. Materials and Methods One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m2, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. Results The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Conclusion Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.
Collapse
Affiliation(s)
- Ruiqi Feng
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Jiajie Tong
- Department of Radiology, Hebei General Hospital, Shijiazhuang 050051, P.R. China
| | - Xiaofei Liu
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Yu Zhao
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| | - Liang Zhang
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang 110001, P.R. China
| |
Collapse
|
26
|
An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2017; 2017:7350429. [PMID: 29097935 PMCID: PMC5612702 DOI: 10.1155/2017/7350429] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 02/26/2017] [Accepted: 05/29/2017] [Indexed: 01/08/2023]
Abstract
Objective To investigate the effectiveness of a new individualized contrast medium injection protocol for enhanced liver CT scan. Methods 324 patients who underwent plain and dual phase enhanced liver CT were randomly assigned to 2 groups: G1 (n = 224, individualized contrast medium injection protocol); G2 (n = 100, standard contrast medium injection with a dose of 1.5 ml/kg). CT values and ΔHU (CT values difference between plain and enhanced CT) of liver parenchyma and tumor-liver contrast (TLC) during hepatic arterial phase (HAP) and portal venous phase (PVP) and contrast medium dose were measured. The tumor conspicuity of hepatocellular carcinoma (HCC) between two groups was independently evaluated by two radiologists. Results The mean contrast medium dose of G1 was statistically lower than that of G2. There were no significantly statistical differences in CT values and ΔHU of liver parenchyma during HAP, TLC values during HAP, and PVP between two groups. The CT values and ΔHU of liver parenchyma during PVP of G2 were significantly higher than those of G1. Two independent radiologists were both in substantial conformity in grading tumor conspicuity. Conclusion Using the individually optimized injection protocol might reduce contrast medium dose without impacting on the imaging quality in enhanced liver CT.
Collapse
|
27
|
Kang D, Hua H, Peng N, Zhao J, Wang Z. Improving Image Quality of Coronary Computed Tomography Angiography Using Patient Weight and Height-Dependent Scan Trigger Threshold. Acad Radiol 2017; 24:462-469. [PMID: 27940232 DOI: 10.1016/j.acra.2016.11.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Revised: 11/01/2016] [Accepted: 11/07/2016] [Indexed: 11/18/2022]
Abstract
RATIONALE AND OBJECTIVES We aim to improve the image quality of coronary computed tomography angiography (CCTA) by using personalized weight and height-dependent scan trigger threshold. MATERIALS AND METHODS This study was divided into two parts. First, we performed and analyzed the 100 scheduled CCTA data, which were acquired by using body mass index-dependent Smart Prep sequence (trigger threshold ranged from 80 Hu to 250 Hu based on body mass index). By identifying the cases of high quality image, a linear regression equation was established to determine the correlation among the Smart Prep threshold, height, and body weight. Furthermore, a quick search table was generated for weight and height-dependent Smart Prep threshold in CCTA scan. Second, to evaluate the effectiveness of the new individual threshold method, an additional 100 consecutive patients were divided into two groups: individualized group (n = 50) with weight and height-dependent threshold and control group (n = 50) with the conventional constant threshold of 150 HU. Image quality was compared between the two groups by measuring the enhancement in coronary artery, aorta, left and right ventricle, and inferior vena cava. By visual inspection, image quality scores were performed to compare between the two groups. RESULTS Regression equation between Smart Prep threshold (K, Hu), height (H, cm), and body weight (BW, kg) was K = 0.811 × H + 1.917 × BW - 99.341. When compared to the control group, the individualized group presented an average overall increase of 12.30% in enhancement in left main coronary artery, 12.94% in proximal right coronary artery, and 10.6% in aorta. Correspondingly, the contrast-to-noise ratios increased by 26.03%, 27.08%, and 23.17%, respectively, and by 633.1% in contrast between aorta and left ventricle. Meanwhile, the individualized group showed an average overall decrease of 22.7% in enhancement of right ventricle and 32.7% in inferior vena cava. There was no significant difference of the image noise between the two groups (P > .05). By visual inspection, the image quality score of the individualized group was higher than that of the control group. CONCLUSION Using personalized weight and height-dependent Smart Prep threshold to adjust scan trigger time can significantly improve the image quality of CCTA.
Collapse
Affiliation(s)
- Deqiang Kang
- Department of Radiology, Dongfang Hospital of Beijing University of Chinese Medicine, Beijing 100078, China
| | - Haiqin Hua
- Department of Radiology, Dongfang Hospital of Beijing University of Chinese Medicine, Beijing 100078, China
| | - Nan Peng
- Department of Radiology, Dongfang Hospital of Beijing University of Chinese Medicine, Beijing 100078, China
| | - Jing Zhao
- Department of Radiology, Dongfang Hospital of Beijing University of Chinese Medicine, Beijing 100078, China
| | - Zhiqun Wang
- Department of Radiology, Dongfang Hospital of Beijing University of Chinese Medicine, Beijing 100078, China.
| |
Collapse
|