1
|
Perera Molligoda Arachchige AS, Teixeira de Castro Gonçalves Ortega AC, Catapano F, Politi LS, Hoff MN. From strength to precision: A systematic review exploring the clinical utility of 7-Tesla magnetic resonance imaging in abdominal imaging. World J Radiol 2024; 16:20-31. [PMID: 38312348 PMCID: PMC10835428 DOI: 10.4329/wjr.v16.i1.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 12/06/2023] [Accepted: 12/25/2023] [Indexed: 01/23/2024] Open
Abstract
BACKGROUND After approval for clinical use in 2017 early investigations of ultra-high-field abdominal magnetic resonance imaging (MRI) have demonstrated the feasibility as well as diagnostic capabilities of liver, kidney, and prostate MRI at 7-Tesla. However, the elevation of the field strength to 7-Tesla not only brought advantages to abdominal MRI but also presented considerable challenges and drawbacks, primarily stemming from heightened artifacts and limitations in Specific Absorption Rate, etc. Furthermore, evidence in the literature is relatively scarce concerning human studies in comparison to phantom/animal studies which necessitates an investigation into the evidence so far in humans and summarizing all relevant evidence. AIM To offer a comprehensive overview of current literature on clinical abdominal 7T MRI that emphasizes current trends, details relevant challenges, and provides a concise set of potential solutions. METHODS This systematic review adheres to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A PubMed search, utilizing Medical Subject Headings terms such as "7-Tesla" and organ-specific terms, was conducted for articles published between January 1, 1985, and July 25, 2023. Eligibility criteria included studies exploring 7T MRI for imaging human abdominal organs, encompassing various study types (in-vivo/ex-vivo, method development, reviews/meta-analyses). Exclusion criteria involved animal studies and those lacking extractable data. Study selection involved initial identification via title/abstract, followed by a full-text review by two researchers, with discrepancies resolved through discussion. Data extraction covered publication details, study design, population, sample size, 7T MRI protocol, image characteristics, endpoints, and conclusions. RESULTS The systematic review included a total of 21 studies. The distribution of clinical 7T abdominal imaging studies revealed a predominant focus on the prostate (n = 8), followed by the kidney (n = 6) and the hepatobiliary system (n = 5). Studies on these organs, and in the pancreas, demonstrated clear advantages at 7T. However, small bowel studies showed no significant improvements compared to traditional MRI at 1.5T. The majority of studies evaluated originated from Germany (n = 10), followed by the Netherlands (n = 5), the United States (n = 5), Austria (n = 2), the United Kingdom (n = 1), and Italy (n = 1). CONCLUSION Further increase of abdominal clinical MRI field strength to 7T demonstrated high imaging potential, yet also limitations mainly due to the inhomogeneous radiofrequency (RF) excitation field relative to lower field strengths. Hence, further optimization of dedicated RF coil elements and pulse sequences are expected to better optimize clinical imaging at high magnetic field strength.
Collapse
Affiliation(s)
| | | | - Federica Catapano
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele 20072, Milan, Italy
- IRCCS Humanitas Research Hospital, Rozzano 20089, Milan, Italy
| | - Letterio S Politi
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele 20072, Milan, Italy
- Department of Neuroradiology, IRCCS Humanitas Research Hospital, Rozzano 20089, Milan, Italy
| | - Michael N Hoff
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA 94143, United States
| |
Collapse
|
2
|
Abstract
Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Dhairya A Lakhani
- From the Department of Radiology, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26506 (D.A.L.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (E.H.M.)
| | - Erik H Middlebrooks
- From the Department of Radiology, West Virginia University, 1 Medical Center Dr, Morgantown, WV 26506 (D.A.L.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (E.H.M.)
| |
Collapse
|
3
|
Wang S, Li J, Zhu D, Hua T, Zhao B. Contrast-enhanced magnetic resonance (MR) T1 mapping with low-dose gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) is promising in identifying clear cell renal cell carcinoma histopathological grade and differentiating fat-poor angiomyolipoma. Quant Imaging Med Surg 2020; 10:988-998. [PMID: 32489923 DOI: 10.21037/qims-19-723] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background This study aimed to identify clear cell renal cell carcinoma (ccRCC) histopathological grade and differentiate it from fat-poor angiomyolipoma (AML). This was achieved through contrast-enhanced magnetic resonance (MR) T1 mapping with intravenous low-dose gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). Methods In total, 56 consecutive patients received MR scanning between January 2016 and December 2018 using the pre- and post- contrast-enhanced T1 mapping sequences with low-dose Gd-DTPA (0.036 mmol/kg). RCCs were pathologically proven in 40 patients after surgery and graded according to the International Society of Urological Pathology (ISUP) classification system. Ten AMLs were pathologically proven by surgery histopathology and six AMLs were diagnosed by magnetic resonance imaging (MRI). Patients were followed up for more than half a year. The mean T1 values of the renal lesion and ipsilateral normal renal parenchyma were measured before and after Gd-DTPA administration (T1p and T1e). The reduction of T1 value (T1d) and the ratio of its reduction (T1d %) were calculated and compared. Results In 40 ccRCCs, higher-grade [International Society of Urologic Pathology (ISUP) grade 3 and 4] and lower-grade (ISUP grade 1 and 2) ccRCCs were noted in 13 and 27 patients, respectively. The mean T1p was 1,514.8±139.4 ms and the mean T1d was 907.7±193.7 ms in the higher-grade ccRCCs, which were significantly higher than in the lower-grade ccRCCs (T1p =1,251.7±151.5 ms and T1d =648.5±218.2 ms, respectively; P<0.001). Fat-poor AMLs had higher T1p (1,677.3±104.8 ms) and T1e (865.6±251.5 ms) as compared to ccRCCs (P<0.001). Combined T1p + T1d showed the highest area under the curve (AUC) (0.912) in the differentiation of higher-grade ccRCCs from lower-grade ccRCCs (P=0.010). Combined T1p + T1e had the highest AUC (0.956) in the differentiation between ccRCCs and fat-poor AMLs (P=0.010). All T1 mapping metrics could discriminate between normal renal parenchyma and renal lesions (P<0.001). No significant difference was found in the T1p and T1e at different parts of the ipsilateral normal renal parenchyma. Interobserver agreement for quantitative longitudinal relaxation time in the T1 maps was excellent. Conclusions Contrast-enhanced T1 mapping with low-dose Gd-DTPA may provide a more reliable and accurate approach in identifying ccRCCs histopathological grade and differentiating ccRCCs from fat-poor AMLs.
Collapse
Affiliation(s)
- Shuai Wang
- Department of Radiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
| | - Junheng Li
- Department of Radiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
| | - Diru Zhu
- Department of Radiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
| | - Ting Hua
- Department of Radiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
| | - Binghui Zhao
- Department of Radiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
| |
Collapse
|
4
|
Lazik-Palm A, Kraff O, Rietsch SHG, Ladd ME, Kamminga M, Beck S, Quick HH, Theysohn JM. 7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff. Eur Radiol Exp 2020; 4:10. [PMID: 32030499 PMCID: PMC7005228 DOI: 10.1186/s41747-019-0142-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 12/06/2019] [Indexed: 01/30/2023] Open
Abstract
Background To evaluate feasibility and diagnostic performance of clinical 7-T magnetic resonance imaging (MRI) of the shoulder. Methods Eight patients with suspected lesions of the rotator cuff underwent 7-T MRI before arthroscopy. Image quality was scored for artifacts, B1+ inhomogeneities, and assessability of anatomical structures. A structured radiological report was compared to arthroscopy. In four patients, a visual comparison with pre-existing 1.5-T examinations was performed. Results Regarding image quality, the majority of the sequences reached values above the middle of each scoring scale. Fat-saturated proton density sequences showed least artifacts and best structure assessability. The most homogenous B1+ field was reached with gradient-echo sequences. Arthroscopy did not confirm tendinopathy/partial tear of supraspinatus in 5/8 patients, of subscapularis in 5/6, and of infraspinatus in one patient; only a partial lesion of the subscapularis tendon was missed. Pathologic findings of long bicipital tendon, acromioclavicular joint, glenohumeral cartilage, labrum, and subacromial subdeltoideal bursa were mainly confirmed; exceptions were one lesion of the long bicipital tendon, one subacromial bursitis, and one superior glenoid labrum anterior-to-posterior lesion, missed on 7-T MRI. Evaluating all structures together, sensitivity was 86%, and specificity 74%. A better contrast and higher image resolution was noted in comparison to previous 1.5-T examinations. Conclusions 7-T MRI of the shoulder with diagnostic image quality is feasible. Overrating of tendon signal alterations was the main limitation. Although the diagnostic performance did not reach the current results of 3-T MRI, our study marks the way to implement clinical 7-T MRI of the shoulder.
Collapse
Affiliation(s)
- Andrea Lazik-Palm
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany. .,Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Germany.
| | - Oliver Kraff
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| | - Stefan H G Rietsch
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany.,High Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Mark E Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany.,Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy and Faculty of Physics, University of Heidelberg, Heidelberg, Germany
| | | | - Sascha Beck
- Department of Trauma and Orthopedic Surgery, University Hospital Essen, University Duisburg-Essen, Essen, Germany.,Department of Orthopaedics and Orthopaedic Surgery, Saarland University Medical Center and Saarland University Faculty of Medicine, Homburg, Germany
| | - Harald H Quick
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany.,High Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, Essen, Germany
| | - Jens M Theysohn
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45147, Essen, Germany
| |
Collapse
|
5
|
Erturk MA, Li X, Van de Moortele PF, Ugurbil K, Metzger GJ. Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions. Top Magn Reson Imaging 2019; 28:101-124. [PMID: 31188271 PMCID: PMC6587233 DOI: 10.1097/rmr.0000000000000202] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
The potential value of ultrahigh field (UHF) magnetic resonance imaging (MRI) and spectroscopy to biomedical research and in clinical applications drives the development of technologies to overcome its many challenges. The increased difficulties of imaging the human torso compared with the head include its overall size, the dimensions and location of its anatomic targets, the increased prevalence and magnitude of physiologic effects, the limited availability of tailored RF coils, and the necessary transmit chain hardware. Tackling these issues involves addressing notoriously inhomogeneous transmit B1 (B1) fields, limitations in peak B1, larger spatial variations of the static magnetic field B0, and patient safety issues related to implants and local RF power deposition. However, as research institutions and vendors continue to innovate, the potential gains are beginning to be realized. Solutions overcoming the unique challenges associated with imaging the human torso are reviewed as are current studies capitalizing on the benefits of UHF in several anatomies and applications. As the field progresses, strategies associated with the RF system architecture, calibration methods, RF pulse optimization, and power monitoring need to be further integrated into the MRI systems making what are currently complex processes more streamlined. Meanwhile, the UHF MRI community must seize the opportunity to build upon what have been so far proof of principle and feasibility studies and begin to further explore the true impact in both research and the clinic.
Collapse
Affiliation(s)
- M Arcan Erturk
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN
| | | | | | | | | |
Collapse
|
6
|
Colafati GS, Rossi E, Carducci C, Piga S, Voicu IP, Mastronuzzi A, Tomà P. Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease. Pediatr Radiol 2018; 48:1724-1735. [PMID: 30046901 DOI: 10.1007/s00247-018-4204-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 05/31/2018] [Accepted: 07/02/2018] [Indexed: 12/15/2022]
Abstract
BACKGROUND Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated. OBJECTIVE To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases. MATERIALS AND METHODS We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses. RESULTS Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8). CONCLUSION In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.
Collapse
Affiliation(s)
- Giovanna Stefania Colafati
- Department of Imaging, Neuroradiology Unit, Bambino Gesù Children's Hospital, Piazza Sant'Onofrio 4, 00165, Rome, Italy.
| | - Enrica Rossi
- Department of Imaging, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Chiara Carducci
- Department of Imaging, Neuroradiology Unit, Bambino Gesù Children's Hospital, Piazza Sant'Onofrio 4, 00165, Rome, Italy
| | - Simone Piga
- Unit of Clinical Epidemiology, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Ioan Paul Voicu
- Department of Hematology/Oncology and Stem Cell Transplantation, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Angela Mastronuzzi
- Department of Hematology/Oncology and Stem Cell Transplantation, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Paolo Tomà
- Department of Imaging, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| |
Collapse
|
7
|
Laader A, Beiderwellen K, Kraff O, Maderwald S, Ladd ME, Forsting M, Umutlu L. Non-enhanced versus low-dose contrast-enhanced renal magnetic resonance angiography at 7 T: a feasibility study. Acta Radiol 2018; 59:296-304. [PMID: 28691526 DOI: 10.1177/0284185117718399] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background Considering the currently reported association between a repetitive application and cumulative dosage of Gadolinium (Gd)-based contrast agents and Gd-deposition in brain tissue as well as the risk for the advent of nephrogenic systemic fibrosis (NSF), techniques allowing for a dose reduction become an important key aspect aside from non-enhanced magnetic resonance angiography (MRA) techniques. Thus, this study was focused on the reduction and/or complete omission of contrast agent for renal MRA at 7T. Purpose To evaluate the performance of time-of-flight MRA versus low-dose contrast-enhanced (CE) renal MRA at 7T. Material and Methods Ten healthy volunteers were examined on a 7T MR system comprising a TOF MRA and three-dimensional (3D) fast low angle shot spoiled gradient-echo sequence (FLASH) MRA after administration of one-quarter of clinical dose of gadobutrol. Qualitative image analysis was performed including overall image quality, artery delineation and presence of artifacts. Contrast ratio (CR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the renal arteries were calculated. Results TOF MRA and low-CE MRA achieved comparable overall ratings, with slightly superior delineation of the main renal arteries in TOF MRA (TOF = 3.10 ± 0.75, low-CE = 2.95 ± 0.75). Segmental branches outside and inside the parenchyma were delineated significantly better on TOF MRA. Quantitative analysis demonstrated the superiority of TOF MRA, yielding higher scores for CR, SNR, and CNR. Conclusion The initial results of our study demonstrate the feasibility and comparable diagnostic performance of TOF and low-dose CE renal MRA at 7T.
Collapse
Affiliation(s)
- Anja Laader
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| | - Karsten Beiderwellen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| | - Oliver Kraff
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| | - Stefan Maderwald
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| | - Mark E Ladd
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Michael Forsting
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
- Erwin L Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
| |
Collapse
|