1
|
Yao F, Li J, Huang M, Gao X, Zhang Y. Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions. Clin Radiol 2024; 79:818-825. [PMID: 39122632 DOI: 10.1016/j.crad.2024.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 06/26/2024] [Accepted: 07/15/2024] [Indexed: 08/12/2024]
Abstract
PURPOSE Combining computed diffusion-weighted imaging (DWI) with readout-segmented echo-planar-imaging may shorten acquisition time and improve imaging quality. This study aimed to compare computed vs. acquired DWI qualitatively and quantitatively in visualizing scrotal or testicular lesions. MATERIALS AND METHODS We retrospectively enrolled 57 consecutive men who underwent scrotal MRI. Four computed DWI sets (cDWI800, cDWI1000, cDWI1200, and cDWI1400) were generated from acquired DWI with two lower b-values (150 and 600 s/mm2). Acquired DWI (DWI800 and DWI1000) and computed DWI were compared through qualitative (susceptibility artifact, signal loss artifact, anatomic clarity, and lesion conspicuity) and quantitative assessment (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion-to-testicular parenchyma contrast ratio (CR)). RESULTS Computed DWI was prone to signal loss artifact and slightly lower assessment scores in terms of anatomic clarity and lesion conspicuity, comparing with acquired DWI. The SNR of computed and acquired DWI decreased with increasing b value. Under the same b-values (800 and 1,000 s/mm2), there was no difference in the median SNR and CR between computed and acquired DWI. The median CR of cDWI1400 was significantly higher than that of the other DWI sets excepting cDWI1200 (P=1.000). The median CNR tended to be lower for computed vs. acquired DWI, while no significant difference (P=0.233). CONCLUSIONS Computed and acquired DWI were nearly equivalent in both qualitative and quantitative evaluations at the b values of 800 and 1,000 s/mm2. Computed DWI could enhance the contrast of scrotal or testicular lesions.
Collapse
Affiliation(s)
- F Yao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China.
| | - J Li
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - M Huang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - X Gao
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| | - Y Zhang
- Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, China
| |
Collapse
|
2
|
Förster A, Ramos A, Wenz H, Groden C, Alonso A. Computed diffusion-weighted imaging in patients with transient neurovascular symptoms with and without ischemic infarction. J Neuroradiol 2024; 51:1-4. [PMID: 36868372 DOI: 10.1016/j.neurad.2023.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 02/25/2023] [Accepted: 02/26/2023] [Indexed: 03/05/2023]
Abstract
PURPOSE Detection of ischemic lesions in patients with transient neurovascular symptoms is relevant for the estimation of the risk of a subsequent stroke and etiological classification. To improve detection rates, different technical approaches have been used, such as diffusion-weighted imaging (DWI) with high b-values or higher magnetic field strength. Here, we sought to investigate the value of computed DWI (cDWI) with high b-values in these patients. METHODS From an MRI report database we identified patients with transient neurovascular symptoms who underwent repeated MRI including DWI. cDWI was calculated with a monoexponential model with high b-values (2000, 3000, and 4000 s/mm2) and compared to the routinely used standard DWI with regard to presence of ischemic lesions and lesion detectability. RESULT Overall 33 patients with transient neurovascular symptoms (71 [IQR 57-83.5] years; 21 [63.6%] male) were included. On DWI, acute ischemic lesions were observed in 22 (78.6%). Acute ischemic lesions were observed in 17 (51.5%) patients on initial DWI, and in 26 (78.8%) patients on follow-up DWI. Lesion detectability was rated significantly better on cDWI at 2000s/mm2 compared to standard DWI. In 2 (9.1%) patients, cDWI at 2000s/mm2 revealed an acute ischemic lesion proven on follow-up standard DWI which was not detected with certainty on the initial standard DWI. CONCLUSION cDWI might be a valuable addition to routinely acquired standard DWI in patients with transient neurovascular symptoms since its use might result in improved ischemic lesion detection. A b-value of 2000s/mm2 seems most promising for clinical practice.
Collapse
Affiliation(s)
- A Förster
- Department of Neuroradiology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany.
| | - Ana Ramos
- Department of Neuroradiology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany
| | - H Wenz
- Department of Neuroradiology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany
| | - C Groden
- Department of Neuroradiology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany
| | - A Alonso
- Department of Neurology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany
| |
Collapse
|
3
|
Xia Y, Zhu L, Cai G, Du L, Wang L, Feng W, Fu C, Ma Q, Dong Y, Pan Z, Yan F, Shen H, Li W, Zhang H. Computed Diffusion-Weighted Images of Rectal Cancer: Image Quality, Restaging, and Treatment Response after Neoadjuvant Therapy. J Magn Reson Imaging 2024; 59:297-308. [PMID: 37165908 DOI: 10.1002/jmri.28766] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 04/25/2023] [Accepted: 04/26/2023] [Indexed: 05/12/2023] Open
Abstract
BACKGROUND Computed diffusion-weighted images (cDWI) of random b value could be derived from acquired DWI (aDWI) with at least two different b values. However, its comparison between aDWI and cDWI images in locally advanced rectal cancer (LARC) patients after neoadjuvant therapy (NT) is needed. PURPOSE To compare the cDWI and aDWI in image quality, restaging, and treatment response of LARC after NT. STUDY TYPE Retrospective. POPULATION Eighty-seven consecutive patients. FIELD STRENGTH/SEQUENCE 3.0 T/DWI. ASSESSMENT All patients underwent two DWI sequences, including conventional acquisition with b = 0 and 1000 s/mm2 (aDWIb1000 ) and another with b = 0 and 700 s/mm2 on a 3.0-T MR scanner. The images of the latter were used to compute the diffusion images with b = 1000 s/mm2 (cDWIb1000 ). Four radiologists with 3, 4, 14, and 25 years of experience evaluated the images to compare the image quality, TN restaging performance, and treatment response between aDWIb1000 and cDWIb1000 . STATISTICAL TESTS Interclass correlation coefficients, weighted κ coefficient, paired Wilcoxon, and McNemar or Fisher test were used. A significance level of 0.05 was used. RESULTS The cDWIb1000 images were superior to the aDWIb1000 ones in both subjective and objective image quality. In T restaging, the overall diagnostic accuracy of cDWIb1000 images was higher than that of aDWIb1000 images (57.47% vs. 49.43%, P = 0.289 for the inexperienced radiologist; 77.01% vs. 63.22%, significant for the experienced radiologist), with better sensitivity in determining ypT0-Tis tumors. Additionally, it increased the sensitivity in detecting ypT2 tumors for the inexperienced radiologist and ypT3 tumors for the experienced radiologist. N restaging and treatment response were found to be similar between two sequences for both radiologists. DATA CONCLUSION Compared to aDWIb1000 images, the computed ones might serve as a wise approach, providing comparable or better image quality, restaging performance, and treatment response assessment for LARC after NT. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Yihan Xia
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Lan Zhu
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Gang Cai
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Lianjun Du
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Lingyun Wang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Weiming Feng
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Caixia Fu
- Department of MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China
| | - Qianchen Ma
- Department of Pathology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Yihan Dong
- Department of Pathology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Zilai Pan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Hailin Shen
- Department of Radiology, Suzhou Kowloon Hospital, Shanghai Jiao Tong University of Medicine, Suzhou, China
| | - Weiguang Li
- Department of Gastroenterology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Huan Zhang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| |
Collapse
|
4
|
Karaman M, Zhou XJ. Editorial for "Computed Diffusion-Weighted Images of Rectal Cancer: Image Quality, Restaging, and Treatment Response after Neoadjuvant Therapy". J Magn Reson Imaging 2024; 59:309-310. [PMID: 37194671 DOI: 10.1002/jmri.28769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 04/18/2023] [Indexed: 05/18/2023] Open
Abstract
Level of Evidence5Technical Efficacy Stage2
Collapse
Affiliation(s)
- Muge Karaman
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
- Departments of Radiology and Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
5
|
Harder FN, Jung E, Weiss K, Graf MM, Kamal O, McTavish S, Van AT, Demir IE, Friess H, Phillip V, Schmid RM, Lohöfer FK, Kaissis GA, Makowski MR, Karampinos DC, Braren RF. Computed high-b-value high-resolution DWI improves solid lesion detection in IPMN of the pancreas. Eur Radiol 2023; 33:6892-6901. [PMID: 37133518 PMCID: PMC10511579 DOI: 10.1007/s00330-023-09661-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 02/15/2023] [Accepted: 02/26/2023] [Indexed: 05/04/2023]
Abstract
OBJECTIVES To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.
Collapse
Affiliation(s)
- Felix N Harder
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
| | - Eva Jung
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Kilian Weiss
- Philips GmbH Market DACH, Röntgenstrasse 22, 22335, Hamburg, Germany
| | - Markus M Graf
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Omar Kamal
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Sean McTavish
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Anh T Van
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Ihsan E Demir
- Department of Surgery, Klinikum Rechts Der Isar, School of Medicine, Technical University of Munich, Munich, Germany
| | - Helmut Friess
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Veit Phillip
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Roland M Schmid
- Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany
| | - Fabian K Lohöfer
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Georgios A Kaissis
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
- Department of Computing, Faculty of Engineering, Imperial College of Science, Technology and Medicine, London, SW7 2AZ, UK
- Institute for Artificial Intelligence in Medicine, Technical University of Munich, Munich, Germany
| | - Marcus R Makowski
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
| | - Dimitrios C Karampinos
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany
| | - Rickmer F Braren
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
| |
Collapse
|
6
|
Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions. Abdom Radiol (NY) 2022; 47:3278-3289. [PMID: 35767024 DOI: 10.1007/s00261-022-03586-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 06/07/2022] [Accepted: 06/08/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE The diagnosis of gallbladder lesions remains challenging. The efficacy of computed diffusion-weighted imaging (DWI) with high b-values and apparent diffusion coefficient (ADC) for the diagnosis of gallbladder cancer remains unknown. We aimed to investigate the usefulness of computed DWI with high b-values and the combination of computed DWI and ADC in differentiating malignant and benign gallbladder lesions. METHODS Sixty patients (comprising 30 malignant and 30 benign lesions) who underwent magnetic resonance imaging for gallbladder lesions were included in this retrospective study. Qualitative evaluations were performed using conventional DWI with b1000, computed DWI with b1500, b1000 DWI/ADC, and computed b1500 DWI/ADC, and their diagnostic performances were compared. RESULTS The sensitivity, specificity, and accuracy of computed b1500 DWI/ADC were 90% (27/30), 80% (24/30), and 85% (51/60), respectively. The accuracy of computed b1500 DWI/ADC was higher than that of conventional b1000 DWI (52%, 31/60, p < 0.001), computed b1500 DWI (72%, 43/60, p = 0.008), and b1000 DWI/ADC (78%, 47/60, p = 0.125). The specificity of computed b1500 DWI/ADC was also higher than that of conventional b1000 DWI (7%, 2/30, p < 0.001), computed b1500 DWI (47%, 14/30, p = 0.002), and b1000 DWI/ADC (67%, 20/30, p = 0.125). No significant difference was observed in the sensitivity between the groups. CONCLUSION This study shows that computed DWI with high b-values combined with ADC can improve diagnostic performance when differentiating malignant and benign gallbladder lesions. Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions. *Computed DWI with b1500 combined with ADC can improve diagnostic performance when differentiating gallbladder lesions compared with conventional methods (b1000 DWI).
Collapse
|
7
|
Delli Pizzi A, Mastrodicasa D, Taraschi A, Civitareale N, Mincuzzi E, Censi S, Marchioni M, Primiceri G, Castellan P, Castellucci R, Cocco G, Chiacchiaretta P, Colasante A, Corvino A, Schips L, Caulo M. Conspicuity and muscle-invasiveness assessment for bladder cancer using VI-RADS: a multi-reader, contrast-free MRI study to determine optimal b-values for diffusion-weighted imaging. Abdom Radiol (NY) 2022; 47:1862-1872. [PMID: 35303112 PMCID: PMC9038787 DOI: 10.1007/s00261-022-03490-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/07/2022] [Accepted: 03/07/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To (1) compare bladder cancer (BC) muscle invasiveness among three b-values using a contrast-free approach based on Vesical Imaging-Reporting and Data System (VI-RADS), to (2) determine if muscle-invasiveness assessment is affected by the reader experience, and to (3) compare BC conspicuity among three b-values, qualitatively and quantitatively. METHODS Thirty-eight patients who underwent a bladder MRI on a 3.0-T scanner were enrolled. The gold standard was histopathology report following transurethral resection of BC. Three sets of images, including T2w and different b-values for DWI, set 1 (b = 1000 s/mm2), set 2 (b = 1500 s/mm2), and set 3 (b = 2000 s/mm2), were reviewed by three differently experienced readers. Descriptive statistics and Intraclass Correlation Coefficient (ICC) were calculated. Comparisons among readers and DWI sets were performed with the Wilcoxon test. Receiver operating characteristic (ROC) analysis was performed. Areas under the curves (AUCs) and pairwise comparison were calculated. RESULTS AUCs of muscle-invasiveness assessment ranged from 0.896 to 0.984 (reader 1), 0.952-0.968 (reader 2), and 0.952-0.984 (reader 3) without significant differences among different sets and readers (p > 0.05). The mean conspicuity qualitative scores were higher in Set 1 (2.21-2.33), followed by Set 2 (2-2.16) and Set 3 (1.82-2.14). The quantitative conspicuity assessment showed that mean normalized intensity of tumor was significantly higher in Set 2 (4.217-4.737) than in Set 1 (3.923-4.492) and Set 3 (3.833-3.992) (p < 0.05). CONCLUSION Muscle invasiveness can be assessed with high accuracy using a contrast-free protocol with T2W and DWI, regardless of reader's experience. b = 1500 s/mm2 showed the best tumor delineation, while b = 1000 s/mm2 allowed for better tumor-wall interface assessment.
Collapse
Affiliation(s)
- Andrea Delli Pizzi
- Department of Innovative Technologies in Medicine & Dentistry, “G. d’Annunzio” University, Chieti, Italy
| | | | - Alessio Taraschi
- Unit of Radiology, “Santissima Annunziata” Hospital, Chieti, Italy
| | | | - Erica Mincuzzi
- Unit of Radiology, “Santissima Annunziata” Hospital, Chieti, Italy
| | - Stefano Censi
- Department of Neuroscience, Imaging and Clinical Sciences, “G. d’Annunzio” University, Chieti, Italy
| | - Michele Marchioni
- Department of Medical, Oral and Biotechnological Sciences, G. d’Annunzio University of Chieti, Urology Unit, SS Annunziata Hospital, Chieti, Italy
- Laboratory of Biostatistics, Department of Medical, Oral and Biotechnological Sciences, “G. D’Annunzio” University, Chieti, Italy
| | - Giulia Primiceri
- Department of Medical, Oral and Biotechnological Sciences, G. d’Annunzio University of Chieti, Urology Unit, SS Annunziata Hospital, Chieti, Italy
| | - Pietro Castellan
- Department of Medical, Oral and Biotechnological Sciences, G. d’Annunzio University of Chieti, Urology Unit, SS Annunziata Hospital, Chieti, Italy
| | - Roberto Castellucci
- Department of Medical, Oral and Biotechnological Sciences, G. d’Annunzio University of Chieti, Urology Unit, SS Annunziata Hospital, Chieti, Italy
| | - Giulio Cocco
- Unit of Ultrasound in Internal Medicine, Department of Medicine and Science of Aging, “G. D’Annunzio” University, Chieti, Italy
| | - Piero Chiacchiaretta
- Center of Advanced Studies and Technology (CAST), “G. d’Annunzio” University of Chieti-Pescara, Chieti, Italy
- Department of Psychological, Health and Territory Sciences, “G. d’Annunzio” University of Chieti-Pescara, Chieti, Italy
| | | | - Antonio Corvino
- Motor Science and Wellness Department, University of Naples “Parthenope”, Naples, Italy
| | - Luigi Schips
- Department of Medical, Oral and Biotechnological Sciences, G. d’Annunzio University of Chieti, Urology Unit, SS Annunziata Hospital, Chieti, Italy
| | - Massimo Caulo
- Department of Neuroscience, Imaging and Clinical Sciences, “G. d’Annunzio” University, Chieti, Italy
| |
Collapse
|
8
|
Xia Y, Wang L, Wu Z, Tan J, Fu M, Fu C, Pan Z, Zhu L, Yan F, Shen H, Ma Q, Cai G. Comparison of Computed and Acquired DWI in the Assessment of Rectal Cancer: Image Quality and Preoperative Staging. Front Oncol 2022; 12:788731. [PMID: 35371999 PMCID: PMC8971285 DOI: 10.3389/fonc.2022.788731] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 02/18/2022] [Indexed: 11/13/2022] Open
Abstract
ObjectiveThe aim of the study was to evaluate the computed diffusion-weighted images (DWI) in image quality and diagnostic performance of rectal cancer by comparing with the acquired DWI.MethodsA total of 103 consecutive patients with primary rectal cancer were enrolled in this study. All patients underwent two DWI sequences, namely, conventional acquisition with b = 0 and 1,000 s/mm2 (aDWIb1,000) and another with b = 0 and 700 s/mm2 on a 3.0T MR scanner (MAGNETOM Prisma; Siemens Healthcare, Germany). The images (b = 0 and 700 s/mm2) were used to compute the diffusion images with b value of 1,000 s/mm2 (cDWIb1,000). Qualitative and quantitative analysis of both computed and acquired DWI images was performed, namely, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal intensity ratio (SIR), and also diagnostic staging performance. Interclass correlation coefficients, weighted κ coefficient, Friedman test, Wilcoxon paired test, and McNemar or Fisher test were used for repeatability and comparison assessment.ResultsCompared with the aDWIb1,000 images, the cDWIb1,000 ones exhibited significant higher scores of subjective image quality (all P <0.050). SNR, SIR, and CNR of the cDWIb1,000 images were superior to those of the aDWIb1,000 ones (P <0.001). The overall diagnostic accuracy of computed images was higher than that of the aDWIb1,000 images in T stage (P <0.001), with markedly better sensitivity and specificity in distinguishing T1–2 tumors from the T3–4 ones (P <0.050).ConclusioncDWIb1,000 images from lower b values might be a useful alternative option and comparable to the acquired DWI, providing better image quality and diagnostic performance in preoperative rectal cancer staging.
Collapse
Affiliation(s)
- Yihan Xia
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Lan Wang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Zhiyuan Wu
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Jingwen Tan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Meng Fu
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Caixia Fu
- Department of MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China
| | - Zilai Pan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Lan Zhu
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
| | - Hailin Shen
- Department of Radiology, Suzhou Kowloon Hospital, Shanghai Jiao Tong University of Medicine, Suzhou, China
- *Correspondence: Gang Cai, ; Qianchen Ma, ; Hailin Shen,
| | - Qianchen Ma
- Department of Pathology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
- *Correspondence: Gang Cai, ; Qianchen Ma, ; Hailin Shen,
| | - Gang Cai
- Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiao Tong University of Medicine, Shanghai, China
- *Correspondence: Gang Cai, ; Qianchen Ma, ; Hailin Shen,
| |
Collapse
|
9
|
High-Resolution, High b-Value Computed Diffusion-Weighted Imaging Improves Detection of Pancreatic Ductal Adenocarcinoma. Cancers (Basel) 2022; 14:cancers14030470. [PMID: 35158737 PMCID: PMC8833466 DOI: 10.3390/cancers14030470] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 01/13/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. Materials and Methods: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1–4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). Results: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. Conclusion: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.
Collapse
|
10
|
Tavakoli AA, Dreher C, Mlynarska A, Kuder TA, Gnirs R, Schlemmer HP, Bickelhaupt S. Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis. Clin Imaging 2021; 83:33-40. [PMID: 34953309 DOI: 10.1016/j.clinimag.2021.11.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 11/08/2021] [Accepted: 11/30/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE To compare image quality of an optimized diffusion weighted imaging (DWI) sequence with advanced post-processing and motion correction (advanced-EPI) to a standard DWI protocol (standard-EPI) in pancreatic imaging. MATERIALS AND METHODS 62 consecutive patients underwent abdominal MRI at 1.5 T were included in this retrospective analysis of data collected as part of an IRB approved study. All patients received a standard-EPI and an advanced-EPI DWI with advanced post-processing and motion correction. Two blinded radiologists evaluated the parameters image quality, detail of parenchyma, sharpness of boundaries and discernibility from adjacent structures on b = 900 s/mm2 images using a Likert-like scale. Segmentation of pancreatic head, body and tail were obtained and apparent diffusion coefficient (ADC) was calculated separately for each region. Apparent tissue-to-background ratio (TBR) was calculated at b = 50 s/mm2 and at b = 900 s/mm2. RESULTS The advanced-EPI yielded significantly higher scores for pancreatic parameters of image quality, detail level of parenchyma, sharpness of boundaries and discernibility from adjacent structures in comparison to standard-EPI (p < 0.001 for all, kappa = [0.46,0.71]) and was preferred in 96% of the cases when directly compared. ADC of the pancreas was 7% lower in advanced-EPI (1.236 ± 0.152 vs. 1.146 ± 0.126 μm2/ms, p < 0.001). ADC in the pancreatic tail was significantly lower for both sequences compared to head and body (all p < 0.001). There was comparable TBR for both sequences at b = 50 s/mm2 (standard-EPI: 19.0 ± 5.9 vs. advanced-EPI: 19.0 ± 6.4, p = 0.96), whereas at b = 900 s/mm2, TBR was 51% higher for advanced-EPI (standard-EPI: 7.1 ± 2.5 vs. advanced-EPI: 10.8 ± 5.1, p < 0.001). CONCLUSION An advanced DWI sequence might increase image quality for focused imaging of the pancreas and providing improved parenchymal detail levels compared to a standard DWI.
Collapse
Affiliation(s)
- Anoshirwan Andrej Tavakoli
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | - Constantin Dreher
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Department of Radiation Oncology, University Medical Center Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| | - Anna Mlynarska
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | - Tristan Anselm Kuder
- German Cancer Research Center (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | - Regula Gnirs
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | - Heinz-Peter Schlemmer
- German Cancer Research Center (DKFZ), Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
| | - Sebastian Bickelhaupt
- German Cancer Research Center (DKFZ), Medical Imaging and Radiology - Cancer Prevention, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; University Hospital Erlangen, Institute of Radiology, Maximiliansplatz 3, 91054 Erlangen, Germany.
| |
Collapse
|
11
|
Sartoretti T, Sartoretti E, Wyss M, Mannil M, van Smoorenburg L, Eichenberger B, Reischauer C, Alfieri A, Binkert C, Sartoretti-Schefer S. Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values. Br J Radiol 2021; 94:20200869. [PMID: 33596102 DOI: 10.1259/bjr.20200869] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Diffusion-weighted imaging (DWI) plays a crucial role in the diagnosis of ischemic stroke. We assessed the value of computed and acquired high b-value DWI in comparison with conventional b = 1000 s mm-2 DWI for ischemic stroke at 3T. METHODS We included 36 patients with acute ischemic stroke who presented with diffusion abnormalities on DWI performed within 24 h of symptom onset. B-values of 0, 500, 1000 and 2000 s mm-2 were acquired. Synthetic images with b-values of 1000, 1500, 2000 and 2500 s mm-2 were computed. Two readers compared synthetic (syn) and acquired (acq) b = 2000 s mm-2 images with acquired b = 1000 s mm-2 images in terms of lesion detection rate, image quality, presence of uncertain hyperintensities and lesion conspicuity. Readers also selected their preferred b-value. Contrast ratio (CR) measurements were performed. Non-parametrical statistical tests and weighted Cohens' κ tests were computed. RESULTS Syn1000 and syn1500 matched acq1000 images in terms of lesion detection rate, image quality and presence of uncertain hyperintensities but presented with significantly improved lesion conspicuity (p < 0.01) and were frequently selected as preferred b-values. Acq2000 images exhibited a similar lesion detection rate and improved lesion conspicuity (p < 0.01) but worse image quality (p < 0.01) than acq1000 images. Syn2000 and syn2500 images performed significantly worse (p < 0.01) than acq1000 images in most or all categories. CR significantly increased with increasing b-values. CONCLUSION Synthetic images at b = 1000 and 1500 s mm-2 and acquired DWI images at b = 2000 s mm-2 may be of clinical value due to improved lesion conspicuity. ADVANCES IN KNOWLEDGE Synthetic b-values enable improved lesion conspicuity for DWI of ischemic stroke.
Collapse
Affiliation(s)
- Thomas Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Faculty of Medicine, University of Zürich, Zürich, Switzerland.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands
| | - Elisabeth Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Faculty of Medicine, University of Zürich, Zürich, Switzerland
| | - Michael Wyss
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Philips Healthsystems, Zürich, Switzerland
| | - Manoj Mannil
- Institute of Neuroradiology, Kantonsspital Aarau, Aarau, Switzerland
| | | | | | - Carolin Reischauer
- Department of Medicine, University of Fribourg, Fribourg, Switzerland.,Department of Radiology, HFR Fribourg-Hôpital Cantonal, Fribourg, Switzerland
| | - Alex Alfieri
- Department of Neurosurgery, Kantonsspital Winterthur, Winterthur, Switzerland
| | - Christoph Binkert
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland
| | | |
Collapse
|
12
|
Ichikawa S, Kromrey ML, Motosugi U, Onishi H. Optimal target b-value on computed diffusion-weighted magnetic resonance imaging for visualization of pancreatic ductal adenocarcinoma and focal autoimmune pancreatitis. Abdom Radiol (NY) 2021; 46:636-646. [PMID: 32740865 DOI: 10.1007/s00261-020-02695-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/21/2020] [Accepted: 07/25/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE To compare computed diffusion-weighted imaging (cDWI) feasibility with that of directly acquired DWI for visualizing pancreatic ductal adenocarcinoma (PDAC) and focal autoimmune pancreatitis (AIP). METHODS From April 2012 to January 2017, 135 patients with PDAC (n = 111) or focal AIP (n = 24) were retrospectively enrolled. They underwent DWI with b-values of 0, 500, and 1000 s/mm2. From DWI0 and DWI1000, we generated cDWIs with targeted b-values of 1500, 2000, and 3000 s/mm2. The lesions' signal intensities, image quality, signal intensity ratio (SIR) of lesions and pancreatic parenchyma to spinal cord, and lesion-to-pancreatic parenchyma contrast ratio (CR) were compared among the five DWI protocols (DWI500, DWI1000, cDWI1500, cDWI2000, and cDWI3000). SIR was analyzed by receiver operating characteristic (ROC) analyses. RESULTS DWI500, DWI1000, and cDWI1500 had higher image quality than cDWI2000 and cDWI3000 (P < 0.001). The incidence of clear hyperintense PDAC was highest on cDWI2000, followed by cDWI1500, and cDWI3000 (P < 0.001-0.002), while the incidence of clear hyperintense AIP was higher on DWI1000, cDWI1500, and cDWI2000 than on DWI500 and cDWI3000 (P = 0.001-0.022). SIRs decreased whereas CRs increased as the b-value increased, for both PDAC and AIP. The area under the ROC curve (AUC) of SIRlesion was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000 (P < 0.001). CONCLUSION cDWI1500 or cDWI2000 generated from b-values of 0 and 1000 s/mm2 were the most effective for visualizing PDAC and focal AIP; however, the SIRlesion AUC was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000.
Collapse
Affiliation(s)
- Shintaro Ichikawa
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan.
| | - Marie-Luise Kromrey
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
- Department of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany
| | - Utaroh Motosugi
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
- Department of Diagnostic Radiology, Kofu Kyoritsu Hospital, Kofu, Yamanashi, Japan
| | - Hiroshi Onishi
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-shi, 409-3898, Yamanashi, Japan
| |
Collapse
|
13
|
Choi BH, Baek HJ, Ha JY, Ryu KH, Moon JI, Park SE, Bae K, Jeon KN, Jung EJ. Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI. Korean J Radiol 2020; 21:1036-1044. [PMID: 32691539 PMCID: PMC7371621 DOI: 10.3348/kjr.2019.0568] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 02/20/2020] [Accepted: 03/17/2020] [Indexed: 01/06/2023] Open
Abstract
OBJECTIVE To investigate the clinical feasibility of synthetic diffusion-weighted imaging (sDWI) at different b-values in patients with breast cancer by assessing the diagnostic image quality and the quantitative measurements compared with conventional diffusion-weighted imaging (cDWI). MATERIALS AND METHODS Fifty patients with breast cancer were assessed using cDWI at b-values of 800 and 1500 s/mm² (cDWI800 and cDWI1500) and sDWI at b-values of 1000 and 1500 s/mm² (sDWI1000 and sDWI1500). Qualitative analysis (normal glandular tissue suppression, overall image quality, and lesion conspicuity) was performed using a 4-point Likert-scale for all DWI sets and the cancer detection rate (CDR) was calculated. We also evaluated cancer-to-parenchyma contrast ratios for each DWI set in 45 patients with the lesion identified on any of the DWI sets. Statistical comparisons were performed using Friedman test, one-way analysis of variance, and Cochran's Q test. RESULTS All parameters of qualitative analysis, cancer-to-parenchyma contrast ratios, and CDR increased with increasing b-values, regardless of the type of imaging (synthetic or conventional) (p < 0.001). Additionally, sDWI1500 provided better lesion conspicuity than cDWI1500 (3.52 ± 0.92 vs. 3.39 ± 0.90, p < 0.05). Although cDWI1500 showed better normal glandular tissue suppression and overall image quality than sDWI1500 (3.66 ± 0.78 and 3.73 ± 0.62 vs. 3.32 ± 0.90 and 3.35 ± 0.81, respectively; p < 0.05), there was no significant difference in their CDR (90.0%). Cancer-to-parenchyma contrast ratios were greater in sDWI1500 than in cDWI1500 (0.63 ± 0.17 vs. 0.55 ± 0.18, p < 0.001). CONCLUSION sDWI1500 can be feasible for evaluating breast cancers in clinical practice. It provides higher tumor conspicuity, better cancer-to-parenchyma contrast ratio, and comparable CDR when compared with cDWI1500.
Collapse
Affiliation(s)
- Bo Hwa Choi
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea.,Department of Radiology, National Cancer Center, Goyang, Korea
| | - Hye Jin Baek
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea.
| | - Ji Young Ha
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Kyeong Hwa Ryu
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Jin Il Moon
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Sung Eun Park
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Kyungsoo Bae
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Kyung Nyeo Jeon
- Department of Radiology Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Eun Jung Jung
- Department of Surgery, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| |
Collapse
|
14
|
Daimiel Naranjo I, Lo Gullo R, Saccarelli C, Thakur SB, Bitencourt A, Morris EA, Jochelson MS, Sevilimedu V, Martinez DF, Pinker-Domenig K. Diagnostic value of diffusion-weighted imaging with synthetic b-values in breast tumors: comparison with dynamic contrast-enhanced and multiparametric MRI. Eur Radiol 2020; 31:356-367. [PMID: 32780207 PMCID: PMC7755636 DOI: 10.1007/s00330-020-07094-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 05/22/2020] [Accepted: 07/21/2020] [Indexed: 12/24/2022]
Abstract
Objectives To assess DWI for tumor visibility and breast cancer detection by the addition of different synthetic b-values. Methods Eighty-four consecutive women who underwent a breast-multiparametric-MRI (mpMRI) with enhancing lesions on DCE-MRI (BI-RADS 2–5) were included in this IRB-approved retrospective study from September 2018 to March 2019. Three readers evaluated DW acquired b-800 and synthetic b-1000, b-1200, b-1500, and b-1800 s/mm2 images for lesion visibility and preferred b-value based on lesion conspicuity. Image quality (1–3 scores) and breast composition (BI-RADS) were also recorded. Diagnostic parameters for DWI were determined using a 1–5 malignancy score based on qualitative imaging parameters (acquired + preferred synthetic b-values) and ADC values. BI-RADS classification was used for DCE-MRI and quantitative ADC values + BI-RADS were used for mpMRI. Results Sixty-four malignant (average = 23 mm) and 39 benign (average = 8 mm) lesions were found in 80 women. Although b-800 achieved the best image quality score, synthetic b-values 1200–1500 s/mm2 were preferred for lesion conspicuity, especially in dense breast. b-800 and synthetic b-1000/b-1200 s/mm2 values allowed the visualization of 84–90% of cancers visible with DCE-MRI performing better than b-1500/b-1800 s/mm2. DWI was more specific (86.3% vs 65.7%, p < 0.001) but less sensitive (62.8% vs 90%, p < 0.001) and accurate (71% vs 80.7%, p = 0.003) than DCE-MRI for breast cancer detection, where mpMRI was the most accurate modality accounting for less false positive cases. Conclusion The addition of synthetic b-values enhances tumor conspicuity and could potentially improve tumor visualization particularly in dense breast. However, its supportive role for DWI breast cancer detection is still not definite. Key Points • The addition of synthetic b-values (1200–1500 s/mm2) to acquired DWI afforded a better lesion conspicuity without increasing acquisition time and was particularly useful in dense breasts. • Despite the use of synthetic b-values, DWI was less sensitive and accurate than DCE-MRI for breast cancer detection. • A multiparametric MRI modality still remains the best approach having the highest accuracy for breast cancer detection and thus reducing the number of unnecessary biopsies. Electronic supplementary material The online version of this article (10.1007/s00330-020-07094-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Isaac Daimiel Naranjo
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Roberto Lo Gullo
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Radiology, Breast Imaging Division, Istituto Europeo di Oncologia, Via Giuseppe Ripamonti, 435, 20141, Milano, Italy
| | - Carolina Saccarelli
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Sunitha B Thakur
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA
| | - Almir Bitencourt
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA.,Department of Imaging, A.C.Camargo Cancer Center, SP, São Paulo, Brazil
| | - Elizabeth A Morris
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Maxine S Jochelson
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Varadan Sevilimedu
- Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA
| | - Danny F Martinez
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Katja Pinker-Domenig
- Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA. .,Department of Biomedical Imaging and Image-guided Therapy Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
| |
Collapse
|
15
|
Tokunaga K, Arizono S, Shimizu H, Fujimoto K, Kurata M, Minamiguchi S, Isoda H, Togashi K. Optimizing b-values for accurate depiction of pancreatic cancer with tumor-associated pancreatitis on computed diffusion-weighted imaging. Clin Imaging 2020; 61:20-26. [PMID: 31954347 DOI: 10.1016/j.clinimag.2020.01.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 12/05/2019] [Accepted: 01/07/2020] [Indexed: 12/19/2022]
Abstract
PURPOSE To determine the optimal b-value for accurate depiction of pancreatic cancer (PC) in patients with active tumor-associated pancreatitis (TAP), using computed diffusion-weighted imaging (cDWI) with a range of b-values up to 3000 s/mm2. METHODS The study protocol was approved by the institutional review board. We retrospectively analyzed 34 consecutive PC cases with active TAP who underwent pancreatectomy without preoperative therapy. Four cDWI datasets with b-values of 1500-3000 s/mm2 (cDWI1500-cDWI3000) were generated from the original DWI datasets with b-values of 0 and 1000 s/mm2 obtained using a 3-T scanner. Two board-certified radiologists evaluated images qualitatively (tumor conspicuity and total image quality), and another two board-certified radiologists placed regions of interest for quantitative evaluations (apparent diffusion coefficient [ADC] values of both lesions, contrast ratio [CR] of PC to active TAP, and volume ratio [VR] of PC to surgical specimen). RESULTS As the b-value increased, tumor conspicuity improved significantly in cDWI2000 and cDWI2500 (P = 0.0121 and 0.0015, respectively), although total image quality decreased in all cDWIs compared with DWI1000 (P < 0.0001). Significantly lower ADC values were seen in PC (P < 0.0001). All cDWI groups showed positive correlation between the tumor conspicuity and ADC difference between PC and TAP. CR increased with the b-value, while VR decreased. Significant equivalence of VR to the surgical specimen was seen on cDWI2000 (P = 0.0031). CONCLUSION Accurate depiction of PC was optimal with cDWI2000 in the presence of active TAP.
Collapse
Affiliation(s)
- Koji Tokunaga
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Shigeki Arizono
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Hironori Shimizu
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Koji Fujimoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Mariyo Kurata
- Department of Diagnostic Pathology, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Sachiko Minamiguchi
- Department of Diagnostic Pathology, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Hiroyoshi Isoda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Kaori Togashi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawaharacho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| |
Collapse
|
16
|
Tumor detectability and conspicuity comparison of standard b1000 and ultrahigh b2000 diffusion-weighted imaging in rectal cancer. Abdom Radiol (NY) 2019; 44:3595-3605. [PMID: 31444557 DOI: 10.1007/s00261-019-02177-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
PURPOSE To compare tumor detectability and conspicuity of standard b = 1000 s/mm2 (b1000) versus ultrahigh b = 2000 s/mm2 (b2000) diffusion-weighted imaging (DWI) in rectal cancer. METHODS Fifty-five patients for a total of 81 3T DWI-MR scans were retrospectively evaluated by two differently experienced readers. A comparison between b1000 and b2000 for tumor detectability and conspicuity was performed. The conspicuity was qualitatively and quantitatively assessed by using three-point scale and whole tumor volume manual delineation, respectively. Receiver-operating characteristic curve (ROC) with area under the curve (AUC) analysis provided diagnostic accuracy in tumor detectability of restaging MR scans. Qualitative scores and quantitative features including mean signal intensity, variance, 10th percentile and 90th percentile, were compared using the Wilcoxon test. Interobserver agreement (IOA) for qualitative and quantitative data was calculated using Cohen's Kappa and intraclass correlation coefficient (ICC) respectively. RESULTS Diagnostic accuracy was comparable between b1000 and b2000 for both readers (p > 0.05). Overall quality scores were significantly better for b2000 than b1000 (2.29 vs 1.65 Reader 1, p = 0.01; 2.18 vs 1.69 Reader 2, p = 0.04). IOA was equally good for both b values (k = 0.86 b1000, k = 0.86 b2000). Quantitative analysis revealed more uniform signal (measured in variance) of b2000 in both healthy surrounding tissue (p < 0.05) and tumor (p < 0.05), with less outliers (measured using 10th and 90th percentile). Additionally, b2000 offered lower mean signal intensity in tissue sorrounding the tumor (p < 0.05). Finally, ICC improved from 0.92 (b1000) to 0.97 (b2000). CONCLUSION Ultrahigh b value (b2000) may improve rectal cancer conspicuity and introbserver agreement maintaining comparable diagnostic accuracy to standard b1000.
Collapse
|