1
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
2
|
Krueger PC, Krämer M, Benkert T, Ertel S, Teichgräber U, Waginger M, Mentzel HJ, Glutig K. Whole-body diffusion magnetic resonance imaging with simultaneous multi-slice excitation in children and adolescents. Pediatr Radiol 2023; 53:1485-1496. [PMID: 36920515 PMCID: PMC10276081 DOI: 10.1007/s00247-023-05622-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 01/27/2023] [Accepted: 01/30/2023] [Indexed: 03/16/2023]
Abstract
BACKGROUND Whole-body magnetic resonance imaging (WB-MRI) is an increasingly used guideline-based imaging modality for oncological and non-oncological pathologies during childhood and adolescence. While diffusion-weighted imaging (DWI), a part of WB-MRI, enhances image interpretation and improves sensitivity, it also requires the longest acquisition time during a typical WB-MRI scan protocol. Interleaved short tau inversion recovery (STIR) DWI with simultaneous multi-slice (SMS) acquisition is an effective way to speed up examinations. OBJECTIVE In this study of children and adolescents, we compared the acquisition time, image quality, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values of an interleaved STIR SMS-DWI sequence with a standard non-accelerated DWI sequence for WB-MRI. MATERIALS AND METHODS Twenty children and adolescents (mean age: 13.9 years) who received two WB-MRI scans at a maximum interval of 18 months, consisting of either standard DWI or SMS-DWI MRI, respectively, were included. For quantitative evaluation, the signal-to-noise ratio (SNR) was determined for b800 images and ADC maps of seven anatomical regions. Image quality evaluation was independently performed by two experienced paediatric radiologists using a 5-point Likert scale. The measurement time per slice stack, pause between measurements including shim and total measurement time of DWI for standard DWI and SMS-DWI were extracted directly from the scan data. RESULTS When including the shim duration, the acquisition time for SMS-DWI was 43% faster than for standard DWI. Qualitatively, the scores of SMS-DWI were higher in six locations in the b800 images and four locations in the ADC maps. There was substantial agreement between both readers, with a Cohen's kappa of 0.75. Quantitatively, the SNR in the b800 images and the ADC maps did not differ significantly from one another. CONCLUSION Whole body-MRI with SMS-DWI provided equivalent image quality and reduced the acquisition time almost by half compared to the standard WB-DWI protocol.
Collapse
Affiliation(s)
- Paul-Christian Krueger
- Section Paediatric Radiology, Department of Radiology, Jena University Hospital, Am Klinikum 1, Jena, Germany
| | - Martin Krämer
- Department of Radiology, Jena University Hospital, Jena, Germany
| | - Thomas Benkert
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Sophia Ertel
- Section Paediatric Radiology, Department of Radiology, Jena University Hospital, Am Klinikum 1, Jena, Germany
| | - Ulf Teichgräber
- Department of Radiology, Jena University Hospital, Jena, Germany
| | - Matthias Waginger
- Section Paediatric Radiology, Department of Radiology, Jena University Hospital, Am Klinikum 1, Jena, Germany
| | - Hans-Joachim Mentzel
- Section Paediatric Radiology, Department of Radiology, Jena University Hospital, Am Klinikum 1, Jena, Germany
| | - Katja Glutig
- Section Paediatric Radiology, Department of Radiology, Jena University Hospital, Am Klinikum 1, Jena, Germany
- Clinic for Radiology – Focus Pediatric Radiology, University of Münster and University Hospital Münster, Albert-Schweitzer-Campus 1 – Building A1, Münster, Germany
| |
Collapse
|
3
|
Larsen SKA, Sivesgaard K, Pedersen EM. Multi-band whole-body diffusion-weighted imaging with inversion recovery fat saturation: Effects of respiratory compensation. Eur J Radiol Open 2021; 8:100374. [PMID: 34485628 PMCID: PMC8403743 DOI: 10.1016/j.ejro.2021.100374] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/20/2021] [Accepted: 08/22/2021] [Indexed: 10/25/2022] Open
Abstract
Purpose To prospectively compare artefacts and image quality in testicular stage I cancer patients using different combinations of breathing schemes and Multi-band (MB) in whole-body DWIBS at 1.5 T.Diffusion-Weighted whole-body Imaging with Background body signal Suppression (DWIBS) using inversion recovery (IR) fat saturation is a cornerstone in oncologic whole-body MRI, but implementation is restrained by long acquisition times. The new Multi-Band (MB) technique reduces scan time which can be reinvested in respiratory compensation. Methods Thirty testicular cancer stage I patients were included. Three variations of whole-body DWIBS were tested: Standard free Breathing (FB)-DWIBS, FB-MB-DWIBS and Respiratory triggered (RT)-MB-DWIBS. Artefacts and image quality of b = 800 s/mm2 images were evaluated using a Likert scale. No pathology was revealed. SNR was calculated in a healthy volunteer. Results RT-MB-DWIBS was rated significantly better than FB-DWIBS in the thorax (p < 0.001) and abdomen (p < 0.001), but not in the pelvis (p = 0.569). FB-MB-DWIBS was ranked significantly lower than both FB-DWIBS (p < 0.001) and RT-MB-DWIBS (p < 0.001) at all locations. However, FB-MB-DWIBS was scanned in half the time without being less than "satisfactory". Few artefacts were encountered. SNR was similar for low-intensity tissues, but the SNR in high-intensity and respiratory-prone tissue (spleen) was slightly lower for FB-DWIBS than the other sequences. Conclusion Images produced by the sequences were similar. MB enables the use of respiratory trigger or can be used to produce very fast free-breathing DWI with acceptable image quality.
Collapse
Key Words
- ADC, apparent diffusion coefficient
- CT, computed tomography
- DWI, diffusion-weighted imaging
- DWIBS, diffusion-weighted whole-body imaging with background body signal suppression
- Diffusion magnetic resonance imaging
- EPI, echo planar imaging
- FB, free-breathing
- IR, inversion recovery
- MB, multi-band
- MRI, magnetic resonance imaging
- Multi-band
- NSA, number of signal averages
- Pet, positron emission tomography
- RF, radio frequency
- ROI, region of interest
- RT, respiratory triggered
- Respiratory compensation
- SAR, specific absorption rate
- SMS, simultaneous multislice
- SNR, signal-to-noise ratio
- SPAIR, spectral attenuated inversion recovery
- T, tesla
- TE, echo time
- TR, repetition time
- Testicular neoplasm
- WB, whole-body
Collapse
Affiliation(s)
| | - Kim Sivesgaard
- Department of Radiology, Aarhus University Hospital, Denmark
| | | |
Collapse
|
4
|
Van Nieuwenhove S, Van Damme J, Padhani AR, Vandecaveye V, Tombal B, Wuts J, Pasoglou V, Lecouvet FE. Whole-body magnetic resonance imaging for prostate cancer assessment: Current status and future directions. J Magn Reson Imaging 2020; 55:653-680. [PMID: 33382151 DOI: 10.1002/jmri.27485] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 12/08/2020] [Accepted: 12/08/2020] [Indexed: 12/20/2022] Open
Abstract
Over the past decade, updated definitions for the different stages of prostate cancer and risk for distant disease, along with the advent of new therapies, have remarkably changed the management of patients. The two expectations from imaging are accurate staging and appropriate assessment of disease response to therapies. Modern, next-generation imaging (NGI) modalities, including whole-body magnetic resonance imaging (WB-MRI) and nuclear medicine (most often prostate-specific membrane antigen [PSMA] positron emission tomography [PET]/computed tomography [CT]) bring added value to these imaging tasks. WB-MRI has proven its superiority over bone scintigraphy (BS) and CT for the detection of distant metastasis, also providing reliable evaluations of disease response to treatment. Comparison of the effectiveness of WB-MRI and molecular nuclear imaging techniques with regard to indications and the definition of their respective/complementary roles in clinical practice is ongoing. This paper illustrates the evolution of WB-MRI imaging protocols, defines the current state-of-the art, and highlights the latest developments and future challenges. The paper presents and discusses WB-MRI indications in the care pathway of men with prostate cancer in specific key situations: response assessment of metastatic disease, "all in one" cancer staging, and oligometastatic disease.
Collapse
Affiliation(s)
- Sandy Van Nieuwenhove
- Department of Radiology and Medical Imaging, Cliniques Universitaires Saint-Luc, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium
| | - Julien Van Damme
- Department of Urology, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Anwar R Padhani
- Mount Vernon Cancer Centre, Mount Vernon Hospital, London, UK
| | - Vincent Vandecaveye
- Department of Radiology and Pathology, University Hospitals Leuven, Leuven, Belgium
| | - Bertrand Tombal
- Department of Urology, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Joris Wuts
- Department of Radiology and Medical Imaging, Cliniques Universitaires Saint-Luc, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium.,Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel, Brussels, Belgium
| | - Vassiliki Pasoglou
- Department of Radiology and Medical Imaging, Cliniques Universitaires Saint-Luc, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium
| | - Frederic E Lecouvet
- Department of Radiology and Medical Imaging, Cliniques Universitaires Saint-Luc, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium
| |
Collapse
|