1
|
Ledesma F, Nishitani S, Cunningham FJ, Hubbard JD, Yim D, Lui A, Chio L, Murali A, Landry MP. Covalent Attachment of Horseradish Peroxidase to Single-Walled Carbon Nanotubes for Hydrogen Peroxide Detection. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.12.14.571773. [PMID: 38168430 PMCID: PMC10760104 DOI: 10.1101/2023.12.14.571773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
Single-walled carbon nanotubes (SWCNTs) are desirable nanoparticles for sensing biological analytes due to their photostability and intrinsic near-infrared fluorescence. Previous strategies for generating SWCNT nanosensors have leveraged nonspecific adsorption of sensing modalities to the hydrophobic SWCNT surface that often require engineering new molecular recognition elements. An attractive alternate strategy is to leverage pre-existing molecular recognition of proteins for analyte specificity, yet attaching proteins to SWCNT for nanosensor generation remains challenging. Towards this end, we introduce a generalizable platform to generate protein-SWCNT-based optical sensors and use this strategy to synthesize a hydrogen peroxide (H 2 O 2 ) nanosensor by covalently attaching horseradish peroxidase (HRP) to the SWCNT surface. We demonstrate a concentration-dependent response to H 2 O 2 , confirm the nanosensor can image H 2 O 2 in real-time, and assess the nanosensor's selectivity for H 2 O 2 against a panel of biologically relevant analytes. Taken together, these results demonstrate successful covalent attachment of enzymes to SWCNTs while preserving both intrinsic SWCNT fluorescence and enzyme function. We anticipate this platform can be adapted to covalently attach other proteins of interest including other enzymes for sensing or antibodies for targeted imaging and cargo delivery.
Collapse
|
2
|
Blanco E, Vázquez L, del Pozo M, Roy R, Petit-Domínguez MD, Quintana C, Casero E. Evaluation of oxidative stress: Nanoparticle-based electrochemical sensors for hydrogen peroxide determination in human semen samples. Bioelectrochemistry 2020; 135:107581. [DOI: 10.1016/j.bioelechem.2020.107581] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Revised: 05/28/2020] [Accepted: 05/31/2020] [Indexed: 11/25/2022]
|
3
|
Ahoulou S, Vilà N, Pillet S, Schaniel D, Walcarius A. Non‐covalent Immobilization of Iron‐triazole (Fe(Htrz)
3
) Molecular Mediator in Mesoporous Silica Films for the Electrochemical Detection of Hydrogen Peroxide. ELECTROANAL 2019. [DOI: 10.1002/elan.201900444] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Samuel Ahoulou
- Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME), UMR7564 CNRS –Université de Lorraine 405 rue de Vandoeuvre 54600 Villers-les-Nancy France
- Université de Lorraine, CNRS, CRM2 UMR7036 54000 Nancy France
| | - Neus Vilà
- Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME), UMR7564 CNRS –Université de Lorraine 405 rue de Vandoeuvre 54600 Villers-les-Nancy France
| | | | | | - Alain Walcarius
- Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME), UMR7564 CNRS –Université de Lorraine 405 rue de Vandoeuvre 54600 Villers-les-Nancy France
| |
Collapse
|
4
|
Kitte SA, Zafar MN, Zholudov YT, Ma X, Nsabimana A, Zhang W, Xu G. Determination of Concentrated Hydrogen Peroxide Free from Oxygen Interference at Stainless Steel Electrode. Anal Chem 2018; 90:8680-8685. [PMID: 29923395 DOI: 10.1021/acs.analchem.8b02038] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
H2O2 is frequently used at high concentrations in various applications. It is very challenging to detect high concentrations of H2O2 and to eliminate oxygen interference for H2O2 detection through electrochemical reduction. In the present investigation, the electrochemistry of H2O2 at stainless steel electrode has been carried out for the first time. A cathodic peak for H2O2 reduction was observed at about -0.40 V, and no cathodic peak for dissolved oxygen reduction was observed on type 304 stainless steel electrode. Amperometric determination of H2O2 on type 304 stainless steel electrode displayed a linear range from 0.05 up to 733 mM with a detection limit of 0.02 mM (S/N = 3) and a sensitivity of 16.7 μA mM-1 cm-2. The type 304 stainless steel electrode not only shows much higher upper limit than other reported electrodes for the detection of concentrated H2O2 but also is free from oxygen interference, which is of great importance for practical applications. This method could detect H2O2 in wound wash and lake water with excellent recoveries. Moreover, we successfully applied the stainless steel electrode to determine glucose using glucose oxidase to catalyze the oxidation of glucose to generate hydrogen peroxide. The linear range for glucose is between 0.5 and 25 mM, which covers clinically important blood glucose concentrations well.
Collapse
Affiliation(s)
- Shimeles Addisu Kitte
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China.,Department of Chemistry, College of Natural Sciences , Jimma University , P.O. Box 378, Jimma , Ethiopia
| | - Muhammad Nadeem Zafar
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,Department of Chemistry , University of Gujrat , Gujrat , Punjab 50700 Pakistan
| | - Yuriy T Zholudov
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,Laboratory of Analytical Optochemotronics , Kharkiv National University of Radio Electronics , 14 Nauka Ave. , Kharkiv , 61166 , Ukraine
| | - Xiangui Ma
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China
| | - Anaclet Nsabimana
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China
| | - Wei Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China
| |
Collapse
|
6
|
Xu Z, Cheng X, Tan J, Gan X. Fabrication of multiwalled carbon nanotube-polyaniline/platinum nanocomposite films toward improved performance for a cholesterol amperometric biosensor. Biotechnol Appl Biochem 2015; 63:757-764. [DOI: 10.1002/bab.1447] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Accepted: 09/25/2015] [Indexed: 11/10/2022]
Affiliation(s)
- ZeHong Xu
- College of Chemistry and Chemical Engineering; Yibin University; Yibin Sichuan People's Republic of China
| | - XiaoDan Cheng
- College of Chemistry and Chemical Engineering; Yibin University; Yibin Sichuan People's Republic of China
| | - JianHong Tan
- College of Chemistry and Chemical Engineering; Yibin University; Yibin Sichuan People's Republic of China
| | - Xianxue Gan
- College of Chemistry and Chemical Engineering; Yibin University; Yibin Sichuan People's Republic of China
| |
Collapse
|
7
|
Cheng H, Chen HT, Hsien KC, Lu CY, Chen PY. New copper complexes incorporated with the one-step preparation of ionic liquid carbon paste electrode for highly selectively reducing hydrogen peroxide. Electrochem commun 2014. [DOI: 10.1016/j.elecom.2013.12.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
10
|
Cañete-Rosales P, Ortega V, Álvarez-Lueje A, Bollo S, González M, Ansón A, Martínez MT. Influence of size and oxidative treatments of multi-walled carbon nanotubes on their electrocatalytic properties. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2011.12.043] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
11
|
Prussian Blue Modified Solid Carbon Nanorod Whisker Paste Composite Electrodes: Evaluation towards the Electroanalytical Sensing ofH2O2. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY 2012. [DOI: 10.1155/2012/238419] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Metallic impurity free solid carbon nanorod “Whiskers” (SCNR Whiskers), a derivative of carbon nanotubes, are explored in the fabrication of a Prussian Blue composite electrode and critically evaluated towards the mediated electroanalytical sensing of H2O2. The sensitivity and detection limits for H2O2on the paste electrodes containing 20% (w/w) Prussian Blue, mineral oil, and carbon nanorod whiskers were explored and found to be 120 mA/(M cm2) and 4.1 μM, respectively, over the concentration range 0.01 to 0.10 mM. Charge transfer constant for the 20% Prussian Blue containing SCNR Whiskers paste electrode was calculated, for the reduction of Prussian Blue to Prussian White, to reveal a value of1.8±0.2 1/s (α=0.43,N=3). Surprisingly, our studies indicate that these metallic impurity-free SCNR Whiskers, in this configuration, behave electrochemically similar to that of an electrode constructed from graphite.
Collapse
|