1
|
Chen T, Liu C, Liu X, Zhu C, Zheng D. Simultaneous Electrochemical Detection of Catechol and Hydroquinone Based on a Carbon Nanotube Paste Electrode Modified with Electro-Reduced Graphene Oxide. Int J Mol Sci 2024; 25:9829. [PMID: 39337317 PMCID: PMC11432359 DOI: 10.3390/ijms25189829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Revised: 09/06/2024] [Accepted: 09/10/2024] [Indexed: 09/30/2024] Open
Abstract
Effectively detecting catechol (CC) and hydroquinone (HQ) simultaneously is crucial for environmental protection and human health monitoring. In the study presented herein, a novel electrochemical sensor for the sensitive simultaneous detection of CC and HQ was constructed based on an electrochemically reduced graphene oxide (ERGO)-modified multi-walled carbon nanotube paste electrode (MWCNTPE). Scanning electron microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy and electrochemical techniques were utilized to characterize the sensing interface and investigate the sensing mechanism. Under the optimal detection conditions, the oxidation peak currents of CC and HQ show a good linear relationship with their concentrations in the range of 0.4-400 μM with a detection limit of 0.083 μM for CC and 0.028 μM for HQ (S/N = 3). Moreover, the sensor exhibits good performance and can be applied successfully in the simultaneous detection of CC and HQ in tap water samples and urine samples with satisfactory results, indicating its promising application prospects.
Collapse
Affiliation(s)
- Tingfei Chen
- School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; (T.C.); (C.L.); (X.L.); (C.Z.)
| | - Chao Liu
- School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; (T.C.); (C.L.); (X.L.); (C.Z.)
- Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China
- Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China
| | - Xiaojun Liu
- School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; (T.C.); (C.L.); (X.L.); (C.Z.)
- Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China
- Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China
| | - Chunnan Zhu
- School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; (T.C.); (C.L.); (X.L.); (C.Z.)
- Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China
- Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China
| | - Dongyun Zheng
- School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; (T.C.); (C.L.); (X.L.); (C.Z.)
- Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China
- Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China
| |
Collapse
|
2
|
Pornea AG, Dinh DK, Hanif Z, Yanar N, Choi KI, Kwak MS, Kim J. Preparations and Thermal Properties of PDMS-AlN-Al 2O 3 Composites through the Incorporation of Poly(Catechol-Amine)-Modified Boron Nitride Nanotubes. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:847. [PMID: 38786803 PMCID: PMC11123707 DOI: 10.3390/nano14100847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 04/23/2024] [Accepted: 05/08/2024] [Indexed: 05/25/2024]
Abstract
As one of the emerging nanomaterials, boron nitride nanotubes (BNNTs) provide promising opportunities for diverse applications due to their unique properties, such as high thermal conductivity, immense inertness, and high-temperature durability, while the instability of BNNTs due to their high surface induces agglomerates susceptible to the loss of their advantages. Therefore, the proper functionalization of BNNTs is crucial to highlight their fundamental characteristics. Herein, a simplistic low-cost approach of BNNT surface modification through catechol-polyamine (CAPA) interfacial polymerization is postulated to improve its dispersibility on the polymeric matrix. The modified BNNT was assimilated as a filler additive with AlN/Al2O3 filling materials in a PDMS polymeric matrix to prepare a thermal interface material (TIM). The resulting composite exhibits a heightened isotropic thermal conductivity of 8.10 W/mK, which is a ~47.27% increase compared to pristine composite 5.50 W/mK, and this can be ascribed to the improved BNNT dispersion forming interconnected phonon pathways and the thermal interface resistance reduction due to its augmented compatibility with the polymeric matrix. Moreover, the fabricated composite manifests a fire resistance improvement of ~10% in LOI relative to the neat composite sample, which can be correlated to the thermal stability shift in the TGA and DTA data. An enhancement in thermal permanence is stipulated due to a melting point (Tm) shift of ∼38.5 °C upon the integration of BNNT-CAPA. This improvement can be associated with the good distribution and adhesion of BNNT-CAPA in the polymeric matrix, integrated with its inherent thermal stability, good charring capability, and free radical scavenging effect due to the presence of CAPA on its surface. This study offers new insights into BNNT utilization and its corresponding incorporation into the polymeric matrix, which provides a prospective direction in the preparation of multifunctional materials for electric devices.
Collapse
Affiliation(s)
- Arni Gesselle Pornea
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| | - Duy Khoe Dinh
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| | - Zahid Hanif
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| | - Numan Yanar
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| | - Ki-In Choi
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| | - Min Seok Kwak
- CMT Co., Ltd., 322 Teheran-ro, Hanshin Intervalley 24 Esat Bldg., Gangnam-gu, Seoul 06211, Republic of Korea;
| | - Jaewoo Kim
- R&D Center, Naieel Technology, 6-2 Yuseongdaero 1205, 2nd FL, Daejeon 34104, Republic of Korea; (A.G.P.); (D.K.D.); (Z.H.); (N.Y.); (K.-I.C.)
| |
Collapse
|
3
|
Ahmed YM, Eldin MA, Galal A, Atta NF. Electrochemical sensor based on PEDOT/CNTs-graphene oxide for simultaneous determination of hazardous hydroquinone, catechol, and nitrite in real water samples. Sci Rep 2024; 14:5654. [PMID: 38454022 PMCID: PMC10920748 DOI: 10.1038/s41598-024-54683-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 02/15/2024] [Indexed: 03/09/2024] Open
Abstract
Hydroquinone (HQ), catechol (CC) and nitrite (NT) are considered aquatic environmental pollutants. They are highly toxic, harm humans' health, and damage the environment. Thus, in the present work we introduce a simple and efficient electrochemical sensor for determination of HQ, CC, and NT simultaneously in wastewater sample. The sensor is fabricated by modifying the surface of a glassy carbon electrode (GCE) by two successive thin films from poly(3,4-ethylenedioxythiophene) (PEDOT) and a mixture of carbon nanotubes-graphene oxide (CNT-GRO). Under optimized conditions the HQ, CC, and NT are successfully detected simultaneously in wastewater sample with changing their concentrations in the ranges (0.04 → 100 µM), (0.01 → 100 µM) and (0.05 → 120 µM), the detection limits are 8.5 nM, 3.8 nM and 6.1 nM, respectively. Good potential peak separations: 117 mV and 585 mV are obtained between the HQ-CC, and CC-NT. The sensor has an excellent catalytic capability toward the oxidation of HQ, CC, and NT due to good synergism between its composite components: PEDOT, GRO and CNTs. The features of the sensor are large active surface area, good electrical conductivity, perfect storage stability, good reproducibility, anti-interference capability and accepted recovery rate for HQ, CC, and NT determination in wastewater sample.
Collapse
Affiliation(s)
- Yousef M Ahmed
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Mahmoud A Eldin
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Ahmed Galal
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Nada F Atta
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
| |
Collapse
|
4
|
Muttaqien SE, Khoris IM, Suryanggono J, Sadhukhan PC, Pambudi S, Chowdhury AD, Park EY. Point-of-care dengue detection: polydopamine-modified electrode for rapid NS1 protein testing for clinical samples. Mikrochim Acta 2024; 191:174. [PMID: 38436801 DOI: 10.1007/s00604-024-06259-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 02/12/2024] [Indexed: 03/05/2024]
Abstract
Early diagnosis of dengue infection by detecting the dengue virus non-structural protein 1 (DENV-NS1) is important to the patients to initiate speedy treatment. Enzyme-linked immunosorbent assay (ELISA)-based NS1 detection and RT-PCR are time-consuming and too complex to be employed in remote areas of dengue-endemic countries. Meanwhile, those of NS1 rapid test by lateral flow assay suffer from low detection limit. Electrochemical-based biosensors using screen-printed gold electrodes (SPGEs) have become a reliable detection method to convey both ELISA's high sensitivity and rapid test portability. In this research, we developed an electrochemical biosensor for DENV-NS1 detection by employing polydopamine (PDA)-modified SPGE. The electrodeposition of PDA on the surface of SPGE serves as a bioconjugation avenue for anti-NS1 antibody through a simple and low-cost immobilization procedure. The biosensor performance was evaluated to detect DENV-NS1 protein in PBS and human serum through a differential pulse voltammetric (DPV) technique. The developed sensing platform displayed a low limit of detection (LOD) of 1.63 pg mL-1 and a wide linear range of 10 pg mL-1 to 1 ng mL-1 (R2 ∼ 0.969). The sensing platform also detected DEV-NS1 from four different serotypes in the clinical samples collected from dengue patients in India and Indonesia, with acceptable sensitivity, specificity, and accuracy values of 90.00%, 80.95%, and 87.65%, respectively. This result showcased the facile and versatile method of PDA coating onto the surface of screen-printed gold electrodes for a miniaturized point-of-care (PoC) detection device.
Collapse
Affiliation(s)
- Sjaikhurrizal El Muttaqien
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan
- Research Center for Vaccine and Drugs, National Research and Innovation Agency (BRIN), LAPTIAB 1, PUSPIPTEK, Tangerang Selatan, 15314, Indonesia
| | - Indra Memdi Khoris
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan
- Nanomaterials Research Division, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8565, Japan
| | - Jodi Suryanggono
- Research Center for Vaccine and Drugs, National Research and Innovation Agency (BRIN), LAPTIAB 1, PUSPIPTEK, Tangerang Selatan, 15314, Indonesia
| | - Provash C Sadhukhan
- ICMR-NICED Virus Laboratory, Kolkata, I.D. & B.G. Hospital, Banerjee Road, Kolkata, 700010, West Bengal, India
| | - Sabar Pambudi
- Research Center for Vaccine and Drugs, National Research and Innovation Agency (BRIN), LAPTIAB 1, PUSPIPTEK, Tangerang Selatan, 15314, Indonesia
| | - Ankan Dutta Chowdhury
- Amity Institute of Nanotechnology, Amity University Kolkata, Kolkata, 700084, West Bengal, India
| | - Enoch Y Park
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan.
| |
Collapse
|
5
|
Hareesha N, Manjunatha J, Tighezza AM, Albaqami MD, Sillanpää M. Electrochemical detection and quantification of catechol based on a simple and sensitive poly(riboflavin) modified carbon nanotube paste electrode. Heliyon 2023; 9:e14378. [PMID: 36942251 PMCID: PMC10023950 DOI: 10.1016/j.heliyon.2023.e14378] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/09/2023] Open
Abstract
In the present research work, selective and sensitive catechol (CT) detection and quantification were shown in the presence of resorcinol (RS) in 0.2 M phosphate buffer (PB) solution by preparing a low-cost, simple, and green carbon nanotube paste electrode (CNTPE) surface activated with electropolymerized riboflavin (PRF). The morphological, conductivity, and electrochemical features of the modified electrode (PRFMCNTPE) and bare carbon nanotube paste electrode (BCNTPE) materials were analyzed using electrochemical impedance spectroscopy (EIS), field emission scanning electron microscopy (FE-SEM), cyclic voltammetry (CV), and differential pulse voltammetry (DPV). The PRF-activated electrode displays outstanding sensitivity, stability, selectivity, reproducibility, and repeatability for the redox feature of CT with improved electrochemical current and declined electrochemical potential compared to BCNTPE. The peak currents of CT are correlated to the different CT concentrations (CV method: 6.0-60.0 μM & DPV method: 0.5-7.0 μM), and the obtained detection limit (DL) and quantification limit (QL) are found to be 0.025 μM and 0.085 μM (CV method) and 0.0039 μM and 0.0132 μM (DPV method), respectively. The prepared PRFMCNTPE material was advantageous for the examination of CT in environmentally important tap water sample as a real-time application.
Collapse
Affiliation(s)
- N. Hareesha
- Department of Chemistry, FMKMC College, Constituent College of Mangalore University, Madikeri, Karnataka, India
| | - J.G. Manjunatha
- Department of Chemistry, FMKMC College, Constituent College of Mangalore University, Madikeri, Karnataka, India
- Corresponding author.
| | - Ammar M. Tighezza
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Munirah D. Albaqami
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Mika Sillanpää
- Department of Biological and Chemical Engineering, Aarhus University, Norrebrogade 44, 8000 Aarhus C, Denmark
| |
Collapse
|
6
|
Moyseowicz A, Minta D, Gryglewicz G. Conductive Polymer/Graphene‐based Composites for Next Generation Energy Storage and Sensing Applications. ChemElectroChem 2023. [DOI: 10.1002/celc.202201145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Affiliation(s)
- Adam Moyseowicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| | - Daria Minta
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| | - Grażyna Gryglewicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| |
Collapse
|
7
|
Dewangan J, Mahamiya V, Shukla A, Chakraborty B. An ab initiostudy of catechol sensing in pristine and transition metal decorated γ-graphyne. NANOTECHNOLOGY 2023; 34:175503. [PMID: 36762606 DOI: 10.1088/1361-6528/acb59d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 12/02/2022] [Indexed: 06/18/2023]
Abstract
Catechol is a toxic biomolecule due to its low degradability to the ecosystem and unpredictable impact on human health. In this work, we have investigated the catechol sensing properties of pristine and transition metal (Ag, Au, Pd, and Ti) decoratedγ-graphyne (GY) systems by employing the density functional theory and first-principles molecular dynamics approach. Simulation results revealed that Pd and Ti atom is more suitable than Ag and Au atom for the decoration of the GY structure with a large charge transfer of 0.29e and 1.54e from valence d-orbitals of the Pd/Ti atom to the carbon-2p orbitals of GY. The GY + Ti system offers excellent electrochemical sensing towards catechol with charge donation of 0.14e from catechol O-p orbitals to Ti-d orbitals, while the catechol molecule is physisorbed to pristine GY with only 0.04e of charge transfer. There exists an energy barrier of 5.19 eV for the diffusion of the Ti atom, which prevents the system from metal-metal clustering. To verify the thermal stability of the sensing material, we have conducted the molecular dynamics simulations at 300 K. We have reported feasible recovery times of 2.05 × 10-5s and 4.7 × 102s for sensing substrate GY + Pd and GY + Ti, respectively, at 500 K of UV light.
Collapse
Affiliation(s)
- Juhee Dewangan
- Department of Physics, Indian Institute of Technology Bombay, 400076 Mumbai, India
| | - Vikram Mahamiya
- Department of Physics, Indian Institute of Technology Bombay, 400076 Mumbai, India
| | - Alok Shukla
- Department of Physics, Indian Institute of Technology Bombay, 400076 Mumbai, India
| | - Brahmananda Chakraborty
- High Pressure and Synchrotron Radiation Physics Division, Bhabha Atomic Research Centre, Bombay, Mumbai 40085, India
- Homi Bhabha National Institute, Mumbai 400094, India
| |
Collapse
|
8
|
Tuning Pore Structure and Specific Surface Area of Graphene Frameworks via One-Step Fast Pyrolysis Strategy: Impact on Electrochemical Sensing Behavior of Catechol. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
9
|
Karami-Kolmoti P, Beitollahi H, Modiri S. Voltammetric detection of catechol in real samples using MnO2 nanorods-graphene oxide nanocomposite modified electrode. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2022. [DOI: 10.1007/s11694-022-01692-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
10
|
Wang Y, Fu Q, Chen J, Lin Y, Yang Y, Wang C, Xie Y, Zhao P, Fei J. Temperature-controlled electrochemical sensor based on environmentally responsive polymer/BiPO4/BiOCl/multi-walled carbon nanotube composite for the detection of catechol in water. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.130543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
11
|
Zhang HJ, Zou X, Chen WY, Sun Q, Gao EQ. A Cu-functionalized MOF and multi-walled carbon nanotube composite modified electrode for the simultaneous determination of hydroquinone and catechol. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3961-3969. [PMID: 36173377 DOI: 10.1039/d2ay01230h] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Designing MOF-based materials with desired electrochemical activity and high electron conductivity may yield a novel electrochemical sensor that effectively detects various organic pollutants and conducts health monitoring. This study developed a facile and versatile electrochemical sensor for simultaneously monitoring the environmental pollutants hydroquinone (HQ) and catechol (CT). The electrodes are fabricated by modifying a GCE with a Cu-functionalized MOF (UiO-bpydc-Cu) and multi-walled carbon nanotubes (MWCNTs). The Cu-functionalized MOF effectively improved the electronic conductivity by metalating the 2,2'-bipyridyl-derived UiO-bpydc with Cu2+ ions. Moreover, due to the synergic effect, the composite electrode exhibits a significant voltammetric response to HQ's and CT's electro-redox. A rapid and sensitive method of synchronously detecting HQ and CT has been established by differential pulse voltammetry (DPV). The experiments reveal that the linear response ranges were 0.5-565 μM and 1-1350 μM for HQ and CT, respectively, with low detection limits of 0.361 μM and 0.245 μM. The proposed UiO-bpydc-Cu/MWCNTs/GCE electrochemical sensor shows high sensitivity, good anti-interference, reproducibility, and stability. It can also be applied for detecting HQ and CT in actual samples.
Collapse
Affiliation(s)
- Hong-Jing Zhang
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, P. R. China.
| | - Xin Zou
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, P. R. China.
| | - Wen-Yi Chen
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, P. R. China.
| | - Qian Sun
- School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, P. R. China.
| | - En-Qing Gao
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200062, P. R. China
| |
Collapse
|
12
|
Al-Shekaili A, Al-Shukaili W, Khudaish EA. A surface network based on oxidative graphene oxide for the determination of hydroquinone and catechol in ground and wastewater samples. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
13
|
Prinith N, Manjunatha JG, Al-Kahtani AA, Tighezza AM, Sillanpää M. Highly Selective and Sensitive Voltammetric Method for the Detection of Catechol in Tea and Water Samples Using Poly(gibberellic acid)-Modified Carbon Paste Electrode. ACS OMEGA 2022; 7:24679-24687. [PMID: 35874207 PMCID: PMC9301953 DOI: 10.1021/acsomega.2c02553] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Despite the wide range of applications of catechol (CC) in agrochemical, petrochemical, textile, cosmetics, and pharmaceutical industries, its exposure to the environment leads to health issues as it is carcinogenic. This increased the concern over the risk of exposure level of CC in the environment, and monitoring its level has become critical. In this work, we report the fabrication of poly-gibberellic acid-modified carbon paste electrode (PGBAMCPE) to be a simple, viable, and effective electrochemical electrode for the determination of CC. This was synthesized by a simple electropolymerization method by the cyclic voltammetry (CV) technique. The electrodes were characterized by field emission electron microscopy, energy-dispersive X-ray spectroscopy, and electrochemical impedance spectroscopy. Compared to the bare carbon paste electrode, the sensitivity for CC fortified at PGBAMCPE in both CV and differential pulse voltammetry (DPV). We succeeded attaining a lower detection limit of 0.57 μM by the DPV method. The developed electrode was observed to be highly conductive, transducing, stable, and reproducible and was highly selective with anti-interfering properties from the determination of CC with hydroquinone simultaneously. The applicability of the electrode was confirmed from the detection CC in tea and water samples with good recoveries. This substantiates that PGBAMCPE is promising and consistent for the rapid monitoring of CC-contaminated area and clinical diagnosis.
Collapse
Affiliation(s)
- Nambudumada
S. Prinith
- Department
of Chemistry, FMKMC College, Constituent
College of Mangalore University, Madikeri 571201, Karnataka, India
| | - J. G. Manjunatha
- Department
of Chemistry, FMKMC College, Constituent
College of Mangalore University, Madikeri 571201, Karnataka, India
| | | | - Ammar M. Tighezza
- Chemistry
Department King Saud University, P.O. box 2455, Riyadh 11451, Saudi Arabia
| | - Mika Sillanpää
- Chemistry
Department, College of Science and Chemical Engineering, Aarhus University, Norrebrogade 44, Aarhus C 8000, Denmark
| |
Collapse
|
14
|
Ramu P, Vimal SP, Suresh P, Sanmugam A, Saravanakumar U, Kumar RS, Almansour AI, Arumugam N, Vikraman D. Investigation of the one-step electrochemical deposition of graphene oxide-doped poly(3,4-ethylenedioxythiophene)-polyphenol oxidase as a dopamine sensor. RSC Adv 2022; 12:15575-15583. [PMID: 35685176 PMCID: PMC9125988 DOI: 10.1039/d2ra00791f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Accepted: 03/14/2022] [Indexed: 12/04/2022] Open
Abstract
In this paper, we fabricated poly(3,4-ethylenedioxythiophene) (PEDOT)-graphene oxide-polyphenol oxidase (PEDOT-GO-PPO) as a dopamine sensor. The morphology of PEDOT-GO-PPO was observed using scanning electron microscopy. Cyclic voltammetry was conducted to study the oxidation-reduction characteristics of dopamine. To optimize the pH, potential and limit of detection of dopamine, the amperometric technique was employed. The found limit of detection was 8 × 10-9 M, and the linear range was from 5 × 10-8 to 8.5 × 10-5 M. The Michaelis-Menten constant (K m) was calculated to be 70.34 μM, and the activation energy of the prepared electrode was 32.75 kJ mol-1. The electrode shows no significant change in the interference study. The modified electrode retains up to 80% of its original activity after 2 months. In the future, the biosensor can be used for the quantification of dopamine in human urine samples. The present modified electrode constitutes a tool for the electrochemical analysis of dopamine.
Collapse
Affiliation(s)
- P Ramu
- Department of Electronics and Communication Engineering, Jaya Institute of Technology Tamilnadu India
| | - S P Vimal
- Department of Electronics and Communication Engineering, Jaya Institute of Technology Tamilnadu India
- Department of Electronics and Communication Engineering, Sri Ramakrishna Engineering College Coimbatore India
| | - P Suresh
- Department of Electronics and Communication Engineering, Vel Tech Rangarajan Dr Sagunthala R & D Institute of Science and Technology Chennai Tamilnadu 600062 India
| | - Anandhavelu Sanmugam
- Department of Applied Chemistry, Sri Vanketeswara College of Engineering Pennalur, Sriperambudur 602117 Chennai India
| | - U Saravanakumar
- Department of Electronics and Communication Engineering, Muthayammal Engineering College Rasipuram Tamilnadu India
| | - Raju Suresh Kumar
- Department of Chemistry, College of Science, King Saud University Riyadh 11451 Saudi Arabia
| | | | - Natarajan Arumugam
- Department of Chemistry, College of Science, King Saud University Riyadh 11451 Saudi Arabia
| | - Dhanasekaran Vikraman
- Division of Electronics and Electrical Engineering, Dongguk University-Seoul Seoul 04620 Korea
| |
Collapse
|
15
|
Liu B, Guo H, Sun L, Pan Z, Peng L, Wang M, Wu N, Chen Y, Wei X, Yang W. Electrochemical sensor based on covalent organic frameworks/MWCNT for simultaneous detection of catechol and hydroquinone. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.128335] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
16
|
Ganesh PS, Kim SY, Kaya S, Salim R. An experimental and theoretical approach to electrochemical sensing of environmentally hazardous dihydroxy benzene isomers at polysorbate modified carbon paste electrode. Sci Rep 2022; 12:2149. [PMID: 35140315 PMCID: PMC8828899 DOI: 10.1038/s41598-022-06207-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 01/19/2022] [Indexed: 12/20/2022] Open
Abstract
It is well known that, surfactants provide a neutral, positive and/or negative charge on the electrode surface by forming a monolayer, which in turn affects the charge transfer and redox potential during the electroanalysis process. However, the molecular level understanding of these surfactant-modified electrodes is worth investigating because the interaction of the analyte with the electrode surface is still unclear. In this report, we used quantum chemical models based on computational density functional theory (DFT) to investigate the polysorbate 80 structure as well as the locations of energy levels and electron transfer sites. Later, the bare carbon paste electrode (bare/CPE) was modified with polysorbate 80 and used to resolve the overlapped oxidation signals of dihydroxy benzene isomers. The m/n values obtained at polysorbate/CPE was approximately equal to 1, signifying the transfer of same number of protons and electrons. Moreover, the analytical applicability of the modified electrode for the determination of catechol (CC) and hydroquinone (HQ) in tap water samples gave an acceptable recovery result. Overall, the application of DFT to understand the molecular level interaction of modifiers for sensing applications laid a new foundation for fabricating electrochemical sensors.
Collapse
Affiliation(s)
- Pattan-Siddappa Ganesh
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, 31253, Chungcheongnam-do, Republic of Korea
| | - Sang-Youn Kim
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, 31253, Chungcheongnam-do, Republic of Korea.
| | - Savas Kaya
- Department of Pharmacy, Health Services Vocational School, Sivas Cumhuriyet University, Sivas, 58140, Turkey
| | - Rajae Salim
- Laboratory of Engineering, Organometallic, Molecular and Environment (LIMOME), Faculty of Science, University Sidi Mohamed Ben Abdellah, Fez, Morocco
| |
Collapse
|
17
|
Rao Q, Hu FX, Gan LY, Guo C, Liu Y, Zhang C, Chen C, Yang HB, Li CM. Boron-Nitrogen-Co-Doping Nanocarbons to Create Rich Electroactive Defects toward Simultaneous Sensing Hydroquinone and Catechol. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139427] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
18
|
Imanzadeh H, Bakirhan NK, Kuralay F, Amiri M, Ozkan SA. Achievements of Graphene and Its Derivatives Materials on Electrochemical Drug Assays and Drug-DNA Interactions. Crit Rev Anal Chem 2021; 53:1263-1284. [PMID: 34941476 DOI: 10.1080/10408347.2021.2018568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Graphene, emerging as a true two-dimensional (2D) material, has attracted increasing attention due to its unique physical and electrochemical properties such as high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass production. The entire scientific community recognizes the significance and potential impact of graphene. Electrochemical detection strategies have advantages such as being simple, fast, and low-cost. The use of graphene as an excellent interface for electrode modification provides a promising way to construct more sensitive and stable electrochemical (bio)sensors. The review presents sensors based on graphene and its derivatives for electrochemical drug assays from pharmaceutical dosage forms and biological samples. Future perspectives in this rapidly developing field are also discussed. In addition, the interaction of several important anticancer drug molecules with deoxyribonucleic acid (DNA) that was immobilized onto graphene-modified electrodes has been detailed in terms of dosage regulation and utility purposes.
Collapse
Affiliation(s)
- Hamideh Imanzadeh
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| | - Nurgul K Bakirhan
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Filiz Kuralay
- Department of Chemistry, Faculty of Science, Hacettepe University, Ankara, Turkey
| | - Mandana Amiri
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Sibel A Ozkan
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| |
Collapse
|
19
|
Conjugated Polymer/Graphene Oxide Nanocomposites—State-of-the-Art. JOURNAL OF COMPOSITES SCIENCE 2021. [DOI: 10.3390/jcs5110292] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Graphene oxide is an imperative modified form of graphene. Similar to graphene, graphene oxide has gained vast interest for the myriad of industrial applications. Conjugated polymers or conducting polymers are well known organic materials having conducting backbone. These polymers have semiconducting nature due to π-conjugation along the main chain. Doping and modification have been used to enhance the electrical conductivity of the conjugated polymers. The nanocomposites of the conjugated polymers have been reported with the nanocarbon nanofillers including graphene oxide. This review essentially presents the structure, properties, and advancements in the field of conducting polymer/graphene oxide nanocomposites. The facile synthesis, processability, and physical properties of the polymer/graphene oxide nanocomposites have been discussed. The conjugated polymer/graphene oxide nanocomposites have essential significance for the supercapacitors, solar cells, and anti-corrosion materials. Nevertheless, the further advanced properties and technical applications of the conjugated polymer/graphene oxide nanocomposites need to be explored to overcome the challenges related to the high performance.
Collapse
|
20
|
Xu Y, Yu Y, Xue S, Ma X, Tao H. Innovative electrochemical sensor based on graphene oxide aerogel wrapped copper centered metal-organic framework to detect catechol. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115686] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
21
|
Sultana S, Noroozifar M, Kerman K. Ruthenium Red-functionalized sol-gel and multi-walled carbon nanotubes for electrochemical simultaneous detection of three dihydroxybenzene isomers. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115644] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
22
|
Coomassie brilliant blue G 250 modified carbon paste electrode sensor for the voltammetric detection of dihydroxybenzene isomers. Sci Rep 2021; 11:15933. [PMID: 34354155 PMCID: PMC8342535 DOI: 10.1038/s41598-021-95347-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 07/22/2021] [Indexed: 11/26/2022] Open
Abstract
In this present study, coomassie brilliant blue G-250 (CBBG) modified electrode was fabricated for the specific and simultaneous detection of three dihydroxybenzene isomers such as resorcinol (RS), catechol (CC) and hydroquinone (HQ). The fabrication of the modified electrode was carried out by electrochemical polymerization of CBBG on the surface of unmodified electrode. The surface structures of bare and fabricated electrode were studied by scanning electron microscope (SEM). The established electrode portrays the very fine interface with these isomers and displayed the sufficient sensitivity and selectivity. The specific parameters of pH solution, scan rate and varying the concentration of analytes were optimized at the modified electrode. The sensor process was originated to be adsorption-controlled activity and the low limit of detection (LOD) for RS and CC was attained at 0.24 and 0.21 µM respectively. In the simultaneous study, designed sensor clearly implies the three well separated anodic peaks for RS, HQ and CC nevertheless in unmodified electrode it failed. Also, the constructed electrode was applied for the real sample analysis in tap water and obtained results are agreeable and it consistent in-between 92.80–99.48%.
Collapse
|
23
|
Selvi SV, Lincy V, Chen SM, Hong PD, Prasannan A. Highly soluble polythiophene-based strontium-doped NiO nanocomposite for effective electrochemical detection of catechol in contaminated water. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2021.116490] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
24
|
Salhi O, Ez‐zine T, El Rhazi M. Hybrid Materials Based on Conducting Polymers for Nitrite Sensing: A Mini Review. ELECTROANAL 2021. [DOI: 10.1002/elan.202100033] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Ouissal Salhi
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| | - Tarik Ez‐zine
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| | - Mama El Rhazi
- Laboratory of Materials Membranes and Environment Morocco Faculty of Sciences and Technologies University Hassan II Casablanca P.B. 146 Mohammedia 20800 Morocco
| |
Collapse
|
25
|
Ponnaiah SK, Prakash P, Balasubramanian J. Effective and reliable platform for nonenzymatic nanomolar-range quinol detection in water samples using ceria doped polypyrrole nanocomposite embedded on graphitic carbon nitride nanosheets. CHEMOSPHERE 2021; 271:129533. [PMID: 33421911 DOI: 10.1016/j.chemosphere.2021.129533] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 12/18/2020] [Accepted: 12/29/2020] [Indexed: 06/12/2023]
Abstract
A glassy carbon electrode modification by a novel ternary nanocomposite of advantageously united ceria, polypyrrole, and graphitic carbon nitride (CeO2/Ppy@g-C3N4) is reported here. It can be used to tailor the sensor surface for the electrochemical detection of nanomolar-level quinol (Qnl), a chemical widely used as a developing agent in photography and lithography, as a cosmetic, and as an antioxidant in rubber and food industries. The occupational exposure of Qnl may occur by inhalation or dermal contact, leading to lot of health hazards. The synthesized nanocomposite was characterized by various analytical techniques such as UV-Vis, Fourier transformed infrared (FTIR), X-ray powder diffraction, field emission scanning electron microscopy, high-resolution transmission electron microscopy, Raman, thermogravimetric analysis, energy-dispersive X-ray spectroscopy, selected area electron diffraction, and elemental mapping analyses. The oxidation current of Qnl is linear to its concentration in the range of 0.01-260 μM and the lowest detection and quantification limit are found to be 1.5 nM and 0.004 μM, respectively, with a sensitivity of 283.33 μA mM-1 cm-2. The performance of the modified electrode was compared with those of high-performance liquid chromatography, which indicates that the proposed sensor can be used as an effective and reliable platform for nano-molar detection of Qnl in various environmental and biological fluids.
Collapse
Affiliation(s)
- Sathish Kumar Ponnaiah
- Department of Chemistry, Thiagarajar College, Madurai, 625 009, Tamil Nadu, India; National Centre of Excellence, MHRD, Thiagarajar College, Madurai, 625 009, Tamil Nadu, India
| | - P Prakash
- Department of Chemistry, Thiagarajar College, Madurai, 625 009, Tamil Nadu, India.
| | - Jeyaprabha Balasubramanian
- Department of Civil Engineering, Sethu Institute of Technology, Virudhunagar, 626 115, Tamil Nadu, India
| |
Collapse
|
26
|
Ganesh PS, Shimoga G, Lee SH, Kim SY, Ebenso EE. Simultaneous electrochemical sensing of dihydroxy benzene isomers at cost-effective allura red polymeric film modified glassy carbon electrode. J Anal Sci Technol 2021. [DOI: 10.1186/s40543-021-00270-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Abstract
Background
A simple and simultaneous electrochemical sensing platform was fabricated by electropolymerization of allura red on glassy carbon electrode (GCE) for the interference-free detection of dihydroxy benzene isomers.
Methods
The modified working electrode was characterized by electrochemical and field emission scanning electron microscopy methods. The modified electrode showed excellent electrocatalytic activity for the electrooxidation of catechol (CC) and hydroquinone (HQ) at physiological pH of 7.4 by cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques.
Results
The effective split in the overlapped oxidation signal of CC and HQ was achieved in a binary mixture with peak to peak separation of 0.102 V and 0.103 V by CV and DPV techniques. The electrode kinetics was found to be adsorption-controlled. The oxidation potential directly depends on the pH of the buffer solution, and it witnessed the transfer of equal number of protons and electrons in the redox phenomenon.
Conclusions
The limit of detection (LOD) for CC and HQ was calculated to be 0.126 μM and 0.132 μM in the linear range of 0 to 80.0 μM and 0 to 110.0 μM, respectively, by ultra-sensitive DPV technique. The practical applicability of the proposed sensor was evaluated for tap water sample analysis, and good recovery rates were observed.
Graphical abstract
Electrocatalytic interaction of ALR/GCE with dihydroxy benzene isomers.
Collapse
|
27
|
Abu Nayem SM, Shaheen Shah S, Sultana N, Aziz MA, Saleh Ahammad AJ. Electrochemical Sensing Platforms of Dihydroxybenzene: Part 1 – Carbon Nanotubes, Graphene, and their Derivatives. CHEM REC 2021; 21:1039-1072. [DOI: 10.1002/tcr.202100043] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/07/2021] [Indexed: 12/12/2022]
Affiliation(s)
- S. M. Abu Nayem
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh 9583794
| | - Syed Shaheen Shah
- Center of Research Excellence in Nanotechnology King Fahd University of Petroleum & Minerals, KFUPM Box 5040 Dhahran 31261 Saudi Arabia
- Physics Department King Fahd University of Petroleum & Minerals, KFUPM Box 5047 Dhahran 31261 Saudi Arabia
| | - Nasrin Sultana
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh 9583794
| | - Md. Abdul Aziz
- Center of Research Excellence in Nanotechnology King Fahd University of Petroleum & Minerals, KFUPM Box 5040 Dhahran 31261 Saudi Arabia
| | | |
Collapse
|
28
|
Lu Z, Wang Y, Hasebe Y, Zhang Z. Electrochemical Sensing Platform Based on Lotus Stem‐derived Porous Carbon for the Simultaneous Determination of Hydroquinone, Catechol and Nitrite. ELECTROANAL 2020. [DOI: 10.1002/elan.202060478] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Zhenyong Lu
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech zone, Anshan Liaoning 114051 China
| | - Yue Wang
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech zone, Anshan Liaoning 114051 China
| | - Yasushi Hasebe
- Department of Life Science and Green Chemistry Saitama Institute of Technology 1690 Fusaiji, Fukaya Saitama 369-0293 Japan
| | - Zhiqiang Zhang
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech zone, Anshan Liaoning 114051 China
| |
Collapse
|
29
|
Kaur G, Kaur A, Kaur H. Review on nanomaterials/conducting polymer based nanocomposites for the development of biosensors and electrochemical sensors. POLYM-PLAST TECH MAT 2020. [DOI: 10.1080/25740881.2020.1844233] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Gagandeep Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| | - Anupreet Kaur
- Basic and Applied Sciences Department, Punjabi University, Patiala, India
| | - Harpreet Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| |
Collapse
|
30
|
Batista LCD, Santos TIS, Santos JEL, Silva DR, Martínez‐Huitle CA. Metal Organic Framework‐235 (MOF‐235) Modified Carbon Paste Electrode for Catechol Determination in Water. ELECTROANAL 2020. [DOI: 10.1002/elan.201800811] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Luiz Carlos Domingos Batista
- Universidade Federal do Rio Grande do Norte Instituto de Química, Laboratório de Eletroquímica Ambiental e Aplicada CEP 59078-970 Natal (RN) Brazil
| | - Thiago Izidoro Silva Santos
- Universidade Federal do Rio Grande do Norte Instituto de Química, Laboratório de Eletroquímica Ambiental e Aplicada CEP 59078-970 Natal (RN) Brazil
| | - José E. Lima Santos
- Universidade Federal do Rio Grande do Norte Instituto de Química, Laboratório de Eletroquímica Ambiental e Aplicada CEP 59078-970 Natal (RN) Brazil
| | - Djalma Ribeiro Silva
- Universidade Federal do Rio Grande do Norte Instituto de Química, Laboratório de Eletroquímica Ambiental e Aplicada CEP 59078-970 Natal (RN) Brazil
| | - Carlos A. Martínez‐Huitle
- Universidade Federal do Rio Grande do Norte Instituto de Química, Laboratório de Eletroquímica Ambiental e Aplicada CEP 59078-970 Natal (RN) Brazil
- Unesp National Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) Institute of Chemistry P.O. Box 355 14800-900 Araraquara SP Brazil
| |
Collapse
|
31
|
Yan L, Yan X, Li H, Zhang X, Wang M, Fu S, Zhang G, Qian C, Yang H, Han J, Xiao F. Reduced graphene oxide nanosheets and gold nanoparticles covalently linked to ferrocene-terminated dendrimer to construct electrochemical sensor with dual signal amplification strategy for ultra-sensitive detection of pesticide in vegetable. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105016] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
32
|
Khalifa Z, Hassan K, Abo Oura MF, Hathoot A, Azzem MA. Individual and Simultaneous Voltammetric Determination of Ultra-Trace Environmental Contaminant Dihydroxybenzene Isomers Based on a Composite Electrode Sandwich-like Structure. ACS OMEGA 2020; 5:18950-18957. [PMID: 32775896 PMCID: PMC7408232 DOI: 10.1021/acsomega.0c02228] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 07/07/2020] [Indexed: 06/11/2023]
Abstract
An advanced electroanalytical technique for the simultaneous assessment of environmental contaminant dihydroxybenzene isomers, catechol (CC), hydroquinone (HQ), and resorcinol (RC), has been investigated using palladium nanoparticles (PdNPs) incorporated onto a poly(1,5-diaminonaphthalene) (DAN) matrix over a glassy carbon electrode (GCE). Concurrently, these types of phenols can be assessed by the PdDAN/GCE modified electrode employing square wave voltammetry and cyclic voltammetry (CV) techniques under optimal conditions. This modified electrode has demonstrated linear responses for CC, HQ, and RC from 50.0 to 1000.0 mM; concomitantly, low detection limits of 0.22, 0.22, and 0.47 nM and low quantification limits of 0.740, 0.758, and 1.590 nM, have been, respectively, shown. Successfully, the simultaneous assessment of the three isomers in river stream water, tap water, and underground water has been implemented via the modified electrode under investigation. In comparison to reported studies, the PdDAN catalytic electrode has shown an effective sensitivity, leverage reproducibility, long-term stability, and excellent anti-interference capability for the determination of dihydroxybenzene isomers.
Collapse
Affiliation(s)
- Ziad Khalifa
- Chemical
Engineering Department, Faculty of Engineering, The British University in Egypt, El Sherouk City 11837 Egypt
| | - Khalid Hassan
- Chemistry
Research Laboratory, Physics and Mathematics Engineering Department,
Faculty of Electronic Engineering, El-Menoufia
University, Menof 23952 Egypt
| | - Mohamed Fathi Abo Oura
- Department
of Chemistry, Faculty of Science, El-Menoufia
University, Shibin
El-Kom, Menoufia 32512 Egypt
| | - Abla Hathoot
- Department
of Chemistry, Faculty of Science, El-Menoufia
University, Shibin
El-Kom, Menoufia 32512 Egypt
| | - Magdi Abdel Azzem
- Department
of Chemistry, Faculty of Science, El-Menoufia
University, Shibin
El-Kom, Menoufia 32512 Egypt
| |
Collapse
|
33
|
Hsu CC, Cheng YW, Liu CC, Peng XY, Yung MC, Liu TY. Anti-Bacterial and Anti-Fouling Capabilities of Poly(3,4-Ethylenedioxythiophene) Derivative Nanohybrid Coatings on SUS316L Stainless Steel by Electrochemical Polymerization. Polymers (Basel) 2020; 12:polym12071467. [PMID: 32629863 PMCID: PMC7407191 DOI: 10.3390/polym12071467] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/23/2020] [Accepted: 06/28/2020] [Indexed: 12/16/2022] Open
Abstract
We have successfully fabricated poly(3,4-ethylenedioxythiophene) (PEDOT) derivative nanohybrid coatings on flexible SUS316L stainless steel by electrochemical polymerization, which can offer anti-fouling and anti-bacterial capabilities. PEDOT derivative nanohybrids were prepared from polystyrene sulfonates (PSS) and graphene oxide (GO) incorporated into a conducting polymer of PEDOT. Additionally, the negative charge of the PEDOT/GO substrate was further modified by poly-diallyldimethylammonium chloride (PDDA) to form a positively charged surface. These PEDOT derivative nanohybrid coatings could provide a straightforward means of controlling the surface energy, roughness, and charges with the addition of various derivatives in the electrochemical polymerization and electrostatically absorbed process. The characteristics of the PEDOT derivative nanohybrid coatings were evaluated by Raman spectroscopy, scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), water contact angle, and surface potential (zeta potential). The results show that PEDOT/PSS and PEDOT/GO nanohybrid coatings exhibit excellent anti-fouling capability. Only 0.1% of bacteria can be adhered on the surface due to the lower surface roughness and negative charge surface by PEDOT/PSS and PEDOT/GO modification. Furthermore, the anti-bacterial capability (7 mm of inhibition zone) was observed after adding PDDA on the PEDOT/GO substrates, suggesting that the positive charge of the PEDOT/GO/PDDA substrate can effectively kill bacteria (Staphylococcus aureus). Given their anti-fouling and anti-bacterial capabilities, PEDOT derivative nanohybrid coatings have the potential to be applied to biomedical devices such as cardiovascular stents and surgical apparatus.
Collapse
Affiliation(s)
- Chuan-Chih Hsu
- Division of Cardiovascular Surgery, Department of Surgery, Taipei Medical University Hospital, Taipei Heart Institute, Taipei Medical University, Taipei 11031, Taiwan;
| | - Yu-Wei Cheng
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan; (C.-C.L.); (X.-Y.P.)
- Correspondence: (Y.-W.C.); (M.-C.Y.); (T.-Y.L.)
| | - Che-Chun Liu
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan; (C.-C.L.); (X.-Y.P.)
| | - Xin-Yao Peng
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan; (C.-C.L.); (X.-Y.P.)
| | - Ming-Chi Yung
- Department of Cardiovascular Surgery, Taiwan Adventist Hospital, and School of Medicine, National Yang Ming University, Taipei 105, Taiwan
- Correspondence: (Y.-W.C.); (M.-C.Y.); (T.-Y.L.)
| | - Ting-Yu Liu
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan; (C.-C.L.); (X.-Y.P.)
- Correspondence: (Y.-W.C.); (M.-C.Y.); (T.-Y.L.)
| |
Collapse
|
34
|
Chetankumar K, Kumara Swamy B. Electrochemically nitric acid pre-treated glassy carbon electrode sensor for catechol and hydroquinone: A voltammetric study. SENSORS INTERNATIONAL 2020. [DOI: 10.1016/j.sintl.2020.100001] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|
35
|
Xiao F, Li H, Yan X, Yan L, Zhang X, Wang M, Qian C, Wang Y. Graphitic carbon nitride/graphene oxide(g-C 3N 4/GO) nanocomposites covalently linked with ferrocene containing dendrimer for ultrasensitive detection of pesticide. Anal Chim Acta 2019; 1103:84-96. [PMID: 32081192 DOI: 10.1016/j.aca.2019.12.066] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 12/18/2019] [Accepted: 12/23/2019] [Indexed: 12/23/2022]
Abstract
We report herein the design of a novel electrochemical sensing strategy for sensitive detection of pesticide based on graphitic carbon nitride (g-C3N4)/graphene oxide(GO) nanocomposite covalently bound to a ferrocene containing dendrimer(Fc-TED). The g-C3N4 with sufficient N atoms for providing lone pairs of electrons to an electron acceptor so as to enhance the adsorption towards organic molecules. The Fc-TED dendrimers with the native redox signaling center (Fe3+/Fe2+) can increase the electron transition of g-C3N4 from valence to conduction band. While GO can accelerate the electron transfer from g-C3N4 surface and Fc-TED to glassy carbon electrode(GCE), which would amplify the electrochemical signal of g-C3N4/GO/Fc-TED/GCE sensor and then improve the sensing performance. It is found that the fabricated electrode demonstrated an admirable electrochemical sensing performance towards metolcarb in terms of low detection limit (8.3 nM), wide concentration range (0.045-213 μM) and rapid response time (2s). The proposed sensor can selectively detect the metolcarb and easily discriminated metolcarb from the possible interfering species. The practical applicability of the sensor was successfully evaluated in real vegetable sample and achieved satisfactory recoveries with good precision and accuracy.
Collapse
Affiliation(s)
- Fengjuan Xiao
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China.
| | - Hongli Li
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Xinrui Yan
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Lu Yan
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Xuefei Zhang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Meng Wang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Cheng Qian
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| | - Yiqi Wang
- School of Material Science and Engineering, Hebei Provincial Key Laboratory of Traffic Engineering Materials, Shijiazhuang Tiedao University, No. 17 North 2nd-Ring East Road, Shijiazhuang, Hebei, China
| |
Collapse
|
36
|
Aydoğdu Tığ G, Pekyardımcı Ş. An electrochemical sandwich-type aptasensor for determination of lipocalin-2 based on graphene oxide/polymer composite and gold nanoparticles. Talanta 2019; 210:120666. [PMID: 31987191 DOI: 10.1016/j.talanta.2019.120666] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 12/16/2019] [Accepted: 12/20/2019] [Indexed: 01/05/2023]
Abstract
In this work, we reported an electrochemical aptasensor based on the poly-3-amino-1,2,4-triazole-5-thiol/graphene oxide composite (P(ATT)-GO) and gold nanoparticles (AuNPs) modified graphite screen-printed electrode (GSPE) (GSPE/P(ATT)-GO/AuNPs) for determination of lipocalin-2 (LCN2) (neutrophil gelatinase-associated lipocalin). A sandwich based strategy was utilized to enhance the electrochemical signal. First, a thiol tethered DNA aptamer was immobilized onto the composite electrode. Then, the LCN2 solution was incubated with the aptamer modified GSPE/P(ATT)-GO/AuNPs. Secondary aptamer (Apt2) peculiar to the LCN2 and labeled with biotin was interacted with the LCN2. A streptavidin-alkaline phosphatase conjugate was then applied to the surface. The determination of LCN2 was performed by using the electroactive property of α-naphthol which is acquired the product from the interaction between alkaline phosphatase and α-naphthyl phosphate. The constructed electrode was characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The aptamer modified GSPE/P(ATT)-GO/AuNPs showed the superior electrocatalytic performance towards the voltammetric determination of LCN2 with a wide linear range (1.0-1000.0 ng/mL) and a low limit of detection (LOD) (0.3 ng/mL). The proposed aptasensor revealed the excellent sensitivity, anti-interference ability and reproducibility which approved that the GSPE/P (ATT)-GO/AuNPs is a promising composite for the sensitive detection of LCN2. The fabricated aptasensor was applied for the determination of LCN2 in fetal bovine serum samples using the standard addition method and the recovery values were in the range of 99.2% and 103.22%.
Collapse
Affiliation(s)
- Gözde Aydoğdu Tığ
- Ankara University, Faculty of Science, Department of Chemistry, Ankara, 06100, Turkey.
| | - Şule Pekyardımcı
- Ankara University, Faculty of Science, Department of Chemistry, Ankara, 06100, Turkey
| |
Collapse
|
37
|
Pd nanoparticles decorated poly-methyldopa@GO/Fe3O4 nanocomposite modified glassy carbon electrode as a new electrochemical sensor for simultaneous determination of acetaminophen and phenylephrine. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 105:110112. [DOI: 10.1016/j.msec.2019.110112] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 08/05/2019] [Accepted: 08/21/2019] [Indexed: 12/15/2022]
|
38
|
Dinesh B, Vilian AE, Kwak CH, Huh YS, Saraswathi R, Han YK. The facile and simple synthesis of poly(3,4ethylenedioxythiophene) anchored reduced graphene oxide nanocomposite for biochemical analysis. Anal Chim Acta 2019; 1077:150-159. [DOI: 10.1016/j.aca.2019.05.053] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 05/21/2019] [Accepted: 05/23/2019] [Indexed: 10/26/2022]
|
39
|
Electrochemical Polymerization of PEDOT-Graphene Oxide-Heparin Composite Coating for Anti-fouling and Anti-clotting of Cardiovascular Stents. Polymers (Basel) 2019; 11:polym11091520. [PMID: 31540544 PMCID: PMC6780510 DOI: 10.3390/polym11091520] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 09/08/2019] [Accepted: 09/16/2019] [Indexed: 11/17/2022] Open
Abstract
In this study, a novel hemocompatible coating on stainless steel substrates was prepared by electrochemically copolymerizing 3,4-ethylenedioxythiophene (EDOT) with graphene oxide (GO), polystyrene sulfonate (PSS), or heparin (HEP) on SUS316L stainless steel, producing an anti-fouling (anti-protein adsorption and anti-platelet adhesion) surface to avoid the restenosis of blood vessels. The negative charges of GO, PSS, and HEP repel negatively charged proteins and platelets to achieve anti-fouling and anti-clotting. The results show that the anti-fouling capability of the poly(3,4-ethylenedioxythiophene) (PEDOT)/PSS coating is similar to that of the PEDOT/HEP coating. The anti-fouling capability of PEDOT/GO is higher than those of PEDOT/HEP and PEDOT/PSS. The reason for this is that GO exhibits negatively charged functional groups (COO−). The highest anti-fouling capability was found with the PEDOT/GO/HEP coating, indicating that electrochemical copolymerization of PEDOT with GO and HEP enhances the anti-fouling capability. Furthermore, the biocompatibility of the PEDOT coatings was tested with 3T3 cells for 1–5 days. The results show that all PEDOT composite coatings exhibited biocompatibility. The blood clotting time (APTT) of PEDOT/GO/HEP was prolonged to 225 s, much longer than the 40 s of pristine SUS316L stainless steel (the control), thus greatly improving the anti-blood-clotting capability of cardiovascular stents.
Collapse
|
40
|
Nishiyama K, Hoshikawa K, Maeki M, Ishida A, Tani H, Tokeshi M. A Concentric Ring Electrode for a Wall‐jet Cell in a Microfluidic Device. ELECTROANAL 2019. [DOI: 10.1002/elan.201900109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Keine Nishiyama
- Graduate School of Chemical Sciences and EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
| | - Koki Hoshikawa
- Graduate School of Chemical Sciences and EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of EngineeringHokkaido University, Kita 13 Nishi 8, Kita-ku Sapporo 060-8628 Japan
- ImPACT Research Center for Advanced NanobiodevicesNagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 Japan
| |
Collapse
|
41
|
Chetankumar K, Swamy BK, Sharma S. Poly (benzoguanamine) modified sensor for catechol in presence of hydroquinone: A voltammetric study. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113365] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
42
|
Simultaneous voltammetric determination of hydroquinone and catechol by using a glassy carbon electrode modified with a ternary nanocomposite prepared from oxidized multiwalled carbon nanotubes, manganese dioxide and manganese ferrite. Mikrochim Acta 2019; 186:643. [PMID: 31444572 DOI: 10.1007/s00604-019-3750-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 08/10/2019] [Indexed: 10/26/2022]
Abstract
An electrochemical sensor is described for simultaneous determination of hydroquinone (HQ) and catechol (CT) via differential pulse voltammetry (DPV). It is making use of a ternary composite material prepared from oxidized multiwalled carbon nanotubes, manganese dioxide (MnO2) and manganese ferrite (MnFe2O4). The material was obtained by a one-step hydrothermal reaction and used to modify a glassy carbon electrode (GCE). The composite was characterized by Fourier transform infrared spectroscopy, X-ray powder diffraction, thermogravimetric analysis, X-ray photoelectron spectroscopy and scanning electron microscopy. The peak currents for HQ and CT are highest at 172 and 276 mV (vs. Ag/AgCl) at a pH value of 6.0. Response increases linearly in the 1-400 μM HQ and CT concentration ranges, and the detection limits are 0.64 and 0.48 μM, respectively. The modified GCE is highly selective, repeatable and reproducible. A single sensor was used to make 23 subsequent measurements, and the relative standard deviations were 1.8% and 2.3% for HQ and CT, respectively. Graphical abstract Schematic representation of the preparation of ternary nanocomposite and its electrochemical behavior towards hydroquinone and catechol.
Collapse
|
43
|
Manjunatha JG. Electrochemical Polymerised Graphene Paste Electrode and Application to Catechol Sensing. ACTA ACUST UNITED AC 2019. [DOI: 10.2174/1874123101913010081] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Objective:
To build up an advantageous strategy for sensitive determination of catechol (CC), a poly (proline) modified graphene paste electrode (PPMGPE) was fabricated and used as a voltammetric sensor for the determination of CC.
Methods:
The performance of the modified electrode was studied using cyclic voltammetric (CV) and differential pulse voltammetric method (DPV). The modified electrode was characterized by CV and DPV. The surface of the modified electrode was examined by FESEM. The electrochemical behavior of CC in phosphate buffer solution (pH 7.5) was inspected using bare graphene paste electrode (BGPE) and PPMGPE.
Results & Conclusion:
The PPMGPE shows a lower limit of detection, calculated to be 8.7×10–7mol L−1 (S/N=3). This modified electrode was applied successfully for the determination of CC in water samples without applying any sample pretreatment.
Collapse
|
44
|
Ahmadi Tabr F, Salehiravesh F, Adelnia H, Gavgani JN, Mahyari M. High sensitivity ammonia detection using metal nanoparticles decorated on graphene macroporous frameworks/polyaniline hybrid. Talanta 2019; 197:457-464. [PMID: 30771962 DOI: 10.1016/j.talanta.2019.01.060] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 01/10/2019] [Accepted: 01/16/2019] [Indexed: 11/17/2022]
Abstract
In this paper, we presented the fabrication and properties of new ammonia (NH3) sensors with sensitive layer of nickel nanoparticles decorated on three-dimensional nitrogen-doped graphene-based frameworks/polyaniline (NiNPs@3D-(N)GFs/PANI) hybrid. The hybrid are synthesized through in-situ oxidative polymerization on flexible thin substrate. Synergetic behavior between both components manifested outstanding sensitivity (750.2 at 1000 ppm NH3) and quick response (95 s) and recovery (25 s) times and a lower limit of detection (~ 45 ppb) at room temperature. The sensitivity of NiNPs@3D-(N)GFs/PANI hybrid sensor was shown to be about 14 times more than its of pure PANI sensor at 1000 ppm of NH3. The excellent sensitivity of the as-prepared hybrid is mainly originated from the substantial rise of hole-like carriers by NiNPs@3D-(N)GFs as well as improved inter-molecule interactions via π- π electron networks. The obtained results revealed significant advantages for the synthesized hybrid sensor, making it a suitable choice for real-world applications of NH3 detection.
Collapse
Affiliation(s)
- Fatemeh Ahmadi Tabr
- Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Iran
| | - Farah Salehiravesh
- Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Iran
| | - Hossein Adelnia
- Australian Institute for Bioengineering and Nanotechnology, University of Queensland, Brisbane, Australia
| | - Jaber Nasrollah Gavgani
- Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Iran.
| | - Mojtaba Mahyari
- Malek-Ashtar University of Technology, P.O. Box 16765-3454, Tehran, Iran.
| |
Collapse
|
45
|
Krzyczmonik P, Skrzypek S. Composites of Poly (3,4-Ethylenedioxythiophene) with Nanostructures as Electrochemical Sensors for Application in Bioelectroanalysis. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411014666180423150941] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Background:
The article presents the state of research on conductive composite materials
constructed on the basis of poly (3,4-ethylenedioxythiophene) (PEDOT), a conductive polymer, as
well as selected nanoparticles and nanostructures. Combining two or more materials in a composite
which is later used in electrode modification can result in obtaining an electrode with new, more desirable
properties. One of such fields is pharmacological analysis which, due to the continuous emergence
of new substances and often also a need for analyte determination in complex samples, requires
newer instruments in the form of suitably sensitive and selective sensors.
Contents:
The review contains the description of properties of PEDOT and composite PEDOT with
polystyrenesulfonates. In the following part, composite materials are described: PEDOT-CNT, PEDOT-
nanoparticles, PEDOT-graphene. The review closes with the examples of multi-component
composite materials.
Conclusion:
The on-going development of new substances used in medicine, pharmacy and related
fields, as well as the continuous increase in the production and consumption of this type of substances,
necessitates constant development and modernization of analytical techniques used for their determination.
:
Biomedical assays require being able to carry out determinations in different systems, including in
vitro ones, without separating individual compounds. It is necessary to be able to identify several substances
simultaneously or determine one compound in the presence of chemically similar substances.
Modern electrode materials such as PEDOT and nanostructured materials allow for the development
of sensors which are getting increasingly better at meeting the requirements of the analysts.
Collapse
Affiliation(s)
- Paweł Krzyczmonik
- Department of Inorganic and Analytical Chemistry, University of Lodz ul. Tamka 12, 91-403 Lodz, Poland
| | - Sławomira Skrzypek
- Department of Inorganic and Analytical Chemistry, University of Lodz ul. Tamka 12, 91-403 Lodz, Poland
| |
Collapse
|
46
|
Simultaneous HPLC-MS determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene after online in-tube solid phase microextraction using a graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composite. Mikrochim Acta 2019; 186:300. [PMID: 31025201 DOI: 10.1007/s00604-019-3429-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 04/10/2019] [Indexed: 12/30/2022]
Abstract
The exploration of monohydroxy polycyclic aromatic hydrocarbons and 8-hydroxy-2'-deoxyguanosine (8-OHdG) produced by oxidative stress and DNA damage is a powerful and non-invasive tool to study the health risk of exposure to polycyclic aromatic hydrocarbons (PAHs). A nanocomposite prepared from graphene oxide, poly(3,4-ethylenedioxythiophene) and polypyrrole was electrodeposited on the internal surface of a stainless-steel tube for online in-tube solid phase microextraction (IT-SPME) of 8-OHdG, 3-hydroxyphenanthrene and 1-hydroxypyrene from urine. The coating possesses excellent chemical and mechanical stability, high extraction efficiency, good resistance to matrix interference, and a long lifespan. An online IT-SPME-high performance liquid chromatography-mass spectrometry method was developed for the determination of these three metabolite biomarkers in human urine. Figures of merit include (a) enrichment factors of 30-48; (b) low limits of detection (4-41 pg·mL-1 at S/N = 3); (c) wide linear ranges (0.05-50 ng·mL-1); (d) good recoveries from spiked samples (71.6-109.5%); and (e) acceptable repeatability (2.3-14.6%). The method offers the advantages of low cost, simplicity, sensitivity, rapidity and automation. Graphical abstract Schematic illustration of online in-tube solid phase microextraction using graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composites as adsorbent in a stainless-steel (SS) tube for the enrichment and simultaneous determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene prior to HPLC-MS analysis.
Collapse
|
47
|
Voltammetric simultaneous determination of catechol and hydroquinone using a glassy carbon electrode modified with a ternary hybrid material composed of reduced graphene oxide, magnetite nanoparticles and gold nanoparticles. Mikrochim Acta 2019; 186:177. [DOI: 10.1007/s00604-019-3273-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 01/20/2019] [Indexed: 01/17/2023]
|
48
|
A novel electrochemical sensor for the selective determination of hydroquinone and catechol using synergic effect of electropolymerized nicotinic acid film and Cd-doped ZnWO4 nanoneedle. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.12.059] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
49
|
Anantha-Iyengar G, Shanmugasundaram K, Nallal M, Lee KP, Whitcombe MJ, Lakshmi D, Sai-Anand G. Functionalized conjugated polymers for sensing and molecular imprinting applications. Prog Polym Sci 2019. [DOI: 10.1016/j.progpolymsci.2018.08.001] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
50
|
Kuskur CM, Kumara Swamy B, Jayadevappa H. Poly (Evans blue) sensor for catechol and hydroquinone: A voltammetric study. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.12.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|