1
|
Santos AM, Wong A, Feitosa MHA, Cardenas-Riojas AA, Calderon-Zavaleta SL, Baena-Moncada AM, Sotomayor MDPT, Moraes FC. Voltammetric Sensing of Nifedipine Using a Glassy Carbon Electrode Modified with Carbon Nanofibers and Gold Nanoparticles. BIOSENSORS 2023; 13:829. [PMID: 37622915 PMCID: PMC10452116 DOI: 10.3390/bios13080829] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/14/2023] [Accepted: 08/18/2023] [Indexed: 08/26/2023]
Abstract
Nifedipine, a widely utilized medication, plays a crucial role in managing blood pressure in humans. Due to its global prevalence and extensive usage, close monitoring is necessary to address this widespread concern effectively. Therefore, the development of an electrochemical sensor based on a glassy carbon electrode modified with carbon nanofibers and gold nanoparticles in a Nafion® film was performed, resulting in an active electrode surface for oxidation of the nifedipine molecule. This was applied, together with a voltammetric methodology, for the analysis of nifedipine in biological and environmental samples, presenting a linear concentration range from 0.020 to 2.5 × 10-6 µmol L-1 with a limit of detection 2.8 nmol L-1. In addition, it presented a good recovery analysis in the complexity of the samples, a low deviation in the presence of interfering potentials, and good repeatability between measurements.
Collapse
Affiliation(s)
- Anderson M. Santos
- Department of Chemistry, Federal University of São Carlos (UFSCar), São Carlos 13560-970, Brazil
| | - Ademar Wong
- Institute of Chemistry, São Paulo State University (UNESP), Araraquara 14801-970, Brazil
| | - Maria H. A. Feitosa
- Department of Chemistry, Federal University of São Carlos (UFSCar), São Carlos 13560-970, Brazil
| | - Andy A. Cardenas-Riojas
- Laboratorio de Investigación de Electroquímica Aplicada, Facultad de Ciencias, Universidad Nacional de Ingeniería, Av. Túpac Amaru 210, Rímac 15333, Peru
| | - Sandy L. Calderon-Zavaleta
- Laboratorio de Investigación de Electroquímica Aplicada, Facultad de Ciencias, Universidad Nacional de Ingeniería, Av. Túpac Amaru 210, Rímac 15333, Peru
| | - Angélica M. Baena-Moncada
- Laboratorio de Investigación de Electroquímica Aplicada, Facultad de Ciencias, Universidad Nacional de Ingeniería, Av. Túpac Amaru 210, Rímac 15333, Peru
| | | | - Fernando C. Moraes
- Department of Chemistry, Federal University of São Carlos (UFSCar), São Carlos 13560-970, Brazil
| |
Collapse
|
2
|
Li Z, Shen F, Mishra RK, Wang Z, Zhao X, Zhu Z. Advances of Drugs Electroanalysis Based on Direct Electrochemical Redox on Electrodes: A Review. Crit Rev Anal Chem 2022; 54:269-314. [PMID: 35575782 DOI: 10.1080/10408347.2022.2072679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The strong development of mankind is inseparable from the proper use of drugs, and the electroanalytical research of drugs occupies an important position in the field of analytical chemistry. This review mainly elaborates the research progress of drugs electroanalysis based on direct electrochemical redox on various electrodes for the recent decade from 2011 to 2021. At first, we summarize some frequently used electrochemical data processing and electrochemical mechanism research derivation methods in the literature. Then, according to the drug therapeutic and application/usage purposes, the research progress of drugs electrochemical analysis is classified and discussed, where we focus on drugs electrochemical reaction mechanism. At the same time, the comparisons of electrochemical sensing performance of the drugs on various electrodes from recent studies are listed, so that readers can more intuitively compare and understand the electroanalytical sensing performance of each modified electrode for each of the drug. Finally, this review discusses the shortcomings and prospects of the drugs electroanalysis based on direct electrochemical redox research.
Collapse
Affiliation(s)
- Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Feichen Shen
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| | - Rupesh K Mishra
- Identify Sensors Biologics at Bindley Bioscience Center, West Lafayette, Indiana, USA
- School of Material Science and Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Zifeng Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Xueling Zhao
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| |
Collapse
|
3
|
Agrawal N, Savalia R, Chatterjee S. Nanostructured zinc oxide film amalgamated with functionalized carbon nanotubes for facile electrochemical determination of nifedipine. Colloids Surf B Biointerfaces 2021; 201:111635. [PMID: 33647712 DOI: 10.1016/j.colsurfb.2021.111635] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 02/02/2021] [Accepted: 02/13/2021] [Indexed: 11/25/2022]
Abstract
An innovative approach has been employed for the detection of nifedipine at glassy carbon electrode fabricated with zinc oxide nanoparticles embedded on functionalized multi walled carbon nanotubes. Herein, square wave voltammetry being an expeditious electrochemical technique has been utilized for the first time for the determination of nifedipine. Instrumental variables were altered to acquire optimized operational parameters. The electrochemical oxidation peak of nifedipine was procured at ∼ 807 mV which was recorded versus Ag/AgCl reference electrode. The oxidation peak was used to quantify the analyte in the dynamic linear range of 1 nM to 40 μM with highest sensitivity and lowest detection limit of 21.8 μA μM-1 and 0.49 nM respectively. The influence of common physiological interferents on the current signal of the analyte was examined. Pronounced stability and reproducibility of fabricated sensor was attained by the neoteric electrochemical approach. The developed protocol was efficaciously applied to quantify nifedipine in pharmaceutical formulations. The urine and blood serum sample of patients being treated for hypertension was effectively detected with nifedipine for the first time. The biological sample assay without the interference of the metabolites coexisting in the samples outlined the insight of selectivity of the developed sensor.
Collapse
Affiliation(s)
- Nikita Agrawal
- Department of Chemistry, Institute of Chemical Technology, Matunga, Mumbai, 400019, India
| | - Rutesh Savalia
- Department of Chemistry, Institute of Chemical Technology, Matunga, Mumbai, 400019, India
| | - Sanghamitra Chatterjee
- Department of Chemistry, Institute of Chemical Technology, Matunga, Mumbai, 400019, India.
| |
Collapse
|
4
|
Electrochemical reduction of Procardia drug with aid of silver phosphate/strontium phosphate nanoparticles (AgP/SrP NPs) modified glassy carbon electrode. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105565] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
5
|
Ağın F, Öztürk G, Kul D. Voltammetric Analysis of Ephedrine in Pharmaceutical Dosage Forms and Urine Using poly(Nile Blue A) Modified Glassy Carbon Electrode. Comb Chem High Throughput Screen 2020; 24:366-375. [PMID: 32718283 DOI: 10.2174/1386207323666200727100231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 05/21/2020] [Accepted: 06/12/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The electrochemical analysis of ephedrine which is a sympathometric drug has been studied using poly(Nile blue A) modified glassy carbon electrodes, cyclic voltammetry, differential pulse voltammetry and square wave voltammetry. METHODS The modified electrodes were prepared by potential cycling electropolymerization of Nile blue A in 0.1 M phosphate buffer solution at pH 6.0. The redox behavior of ephedrine was investigated in different buffer solutions at pH values between 5.5 and 9.0. RESULTS Scan rate studies showed that the electron transfer reaction of ephedrine was diffusion controlled. A linear response was obtained between the peak current and the ephedrine concentration in the range of 0.6 to 100 μM with a limit of detection of 2.91×10-3 μM for differential pulse voltammetry in Britton-Robinson buffer solution at pH 9.0. The linearity range of ephedrine in human urine was between 1.0 and 100 μM with a detection limit of 8.16 nM. CONCLUSION The recovery studies in both pharmaceutical dosage forms and urine showed that the proposed method ensured good selectivity, precision and accuracy without any interference from inactive excipients.
Collapse
Affiliation(s)
- Fatma Ağın
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| | - Gökçe Öztürk
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| | - Dilek Kul
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Ortahisar, 61080, Trabzon, Turkey
| |
Collapse
|
6
|
Zhang Y, Ma Y, Wang L. Simple Copper Nanoparticle/Polyfurfural Film Modified Electrode for the Determination of 2, 4, 6-Trinitrotoluene (TNT). ANAL LETT 2020. [DOI: 10.1080/00032719.2020.1751182] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Yunlong Zhang
- College of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, China
| | - Ya Ma
- College of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, China
| | - Lishi Wang
- College of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, China
| |
Collapse
|
7
|
Abstract
Background:Calcium Channel Blockers (CCBs) are widely used in the treatment of cardiovascular and ischemic heart diseases in recent years. They treat arrhythmias by reducing cardiac cycle contraction and also benefit ischemic heart diseases. Electroanalytical methods are very powerful analytical methods used in the pharmaceutical industry because of the determination of therapeutic agents and/or their metabolites in clinical samples at extremely low concentrations (10-50 ng/ml). The purpose of this review is to gather electroanalytical methods used for the determination of calcium channel blocker drugs in pharmaceutical dosage forms and biological media selected mainly from current articles.Methods:This review mainly includes recent determination studies of calcium channel blockers by electroanalytical methods from pharmaceutical dosage forms and biological samples. The studies of calcium channel blockers electroanalytical determination in the literature were reviewed and interpreted.Results:There are a lot of studies on amlodipine and nifedipine, but the number of studies on benidipine, cilnidipine, felodipine, isradipine, lercanidipine, lacidipine, levamlodipine, manidipine, nicardipine, nilvadipine, nimodipine, nisoldipine, nitrendipine, diltiazem, and verapamil are limited in the literature. In these studies, DPV and SWV are the most used methods. The other methods were used less for the determination of calcium channel blocker drugs.Conclusion:Electroanalytical methods especially voltammetric methods supply reproducible and reliable results for the analysis of the analyte. These methods are simple, more sensitive, rapid and inexpensive compared to the usually used spectroscopic and chromatographic methods.
Collapse
Affiliation(s)
- Fatma Ağın
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Trabzon, Turkey
| |
Collapse
|
8
|
Sundaresan P, Karthik R, Chen SM, Vinoth Kumar J, Muthuraj V, Nagarajan ER. Ultrasonication-assisted synthesis of sphere-like strontium cerate nanoparticles (SrCeO 3 NPs) for the selective electrochemical detection of calcium channel antagonists nifedipine. ULTRASONICS SONOCHEMISTRY 2019; 53:44-54. [PMID: 30559078 DOI: 10.1016/j.ultsonch.2018.12.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 12/05/2018] [Accepted: 12/08/2018] [Indexed: 06/09/2023]
Abstract
In this work, strontium cerate nanoparticles (SrCeO3 NPs, SC NPs) were developed through facile synthetic techniques (Ultrasound-Assisted (UA) and Stirring-Assisted (SA) synthesis) and utilized as an electrocatalyst for the selective and sensitive electrochemical detection of calcium channel blocker nifedipine (NDF). The as-prepared UASC NPs and SASC NPs were characterized using XRD, Raman, TEM, EDS, mapping, XPS and BET analysis which exposed the formation of SC NPs in the form of spherical in shape and well crystalline in nature. BET studies reveal that UASC NPs have maximum surface area than that of SASC NPs. Further, the use of the as-developed UASC NPs and SASC NPs as an electrocatalyst for the detection of NDF. Interestingly, the UASC NPs modified screen printed carbon electrode (UASC NPs/SPCE) exhibited an excellent electrocatalytic activity in terms of lower reduction potential and enhanced reduction peak current when compared to SASC NPs and unmodified SPCE. Moreover, as-prepared UASC NPs/SPCE displayed wide linear response range (LR, 0.02-174 µM), lower detection limit (LOD, 5 nM) and good sensitivity (1.31 µA µM-1 cm-2) than that of SASC NPs (LR = 0.02-157 µM, LOD = 6.4 nM, sensitivity - 1.27 µA µM-1cm-2). Furthermore, UASC NPs/SPCE showed an excellent selectivity even in the existence of potentially co-interfering compounds such as similar functional group containing drugs, pollutants, biological substances and some common cations/anions. The developed sensor was successfully employed for the determination of NDF in real lake water, commercial NDF tablet and urine samples with acceptable recovery.
Collapse
Affiliation(s)
- Periyasamy Sundaresan
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, ROC
| | - Raj Karthik
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, ROC
| | - Shen-Ming Chen
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, ROC.
| | - Jeyaraj Vinoth Kumar
- Department of Chemistry, VHNSN College, Virudhunagar 626001, Tamil Nadu, India; Department of Chemistry, Nanomaterials Laboratory, IRC, Kalasalingam Academy of Research and Education, Krishnankoil 626 126, Tamil Nadu, India
| | - Velluchamy Muthuraj
- Department of Chemistry, VHNSN College, Virudhunagar 626001, Tamil Nadu, India
| | - E R Nagarajan
- Department of Chemistry, Nanomaterials Laboratory, IRC, Kalasalingam Academy of Research and Education, Krishnankoil 626 126, Tamil Nadu, India
| |
Collapse
|
9
|
Mokhtari B, Nematollahi D, Salehzadeh H. Electrochemical simultaneous determination of nifedipine and its main metabolite dehydronifedipine using MWCNT modified glassy carbon electrode. J Mol Liq 2018. [DOI: 10.1016/j.molliq.2018.05.082] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Ye F, Huang J, Xu Y, Zeng Q, Nan J, Wang L. Polyfurfural-Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode for the Direct Determination of Nitrofurazone. ANAL LETT 2017. [DOI: 10.1080/00032719.2017.1360898] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Fang Ye
- School of Chemistry and Environment Engineering, Shaoguan College, Shaoguan, P. R. China
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, P. R. China
| | - Jianzhi Huang
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, P. R. China
| | - Yongqun Xu
- School of Chemistry and Environment Engineering, Shaoguan College, Shaoguan, P. R. China
| | - Qiang Zeng
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, P. R. China
| | - Junmin Nan
- School of Chemistry and Environment, South China Normal University, Guangzhou, P. R. China
| | - Lishi Wang
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, P. R. China
| |
Collapse
|
11
|
Huang J, Shen X, Wang R, Zeng Q, Wang L. A highly sensitive metronidazole sensor based on a Pt nanospheres/polyfurfural film modified electrode. RSC Adv 2017. [DOI: 10.1039/c6ra25106d] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
A sensitively electrochemical metronidazole sensor basing on a Pt nanospheres/polyfurfural modified glassy carbon electrode.
Collapse
Affiliation(s)
- Jianzhi Huang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Xiaolei Shen
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Ruili Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Qiang Zeng
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
- State Key Laboratory of Pulp and Paper Engineering
| | - Lishi Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| |
Collapse
|
12
|
Huang J, Bai S, Yue G, Cheng W, Wang L. Coordination matrix/signal amplifier strategy for simultaneous electrochemical determination of cadmium(ii), lead(ii), copper(ii), and mercury(ii) ions based on polyfurfural film/multi-walled carbon nanotube modified electrode. RSC Adv 2017. [DOI: 10.1039/c7ra04029f] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Coordination matrix/signal amplifier strategy for simultaneous electrochemical determination of cadmium(ii), lead(ii), copper(ii) and mercury(ii) ions based on polyfurfural film/multi-walled carbon nanotubes modified electrode.
Collapse
Affiliation(s)
- Jianzhi Huang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Silan Bai
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Guoqing Yue
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Wenxue Cheng
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Lishi Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| |
Collapse
|
13
|
Cheng W, Huang J, Liu C, Zeng Q, Tong Y, Wang L, Cheng F. High sensitivity chlorogenic acid detection based on multiple layer-by-layer self-assembly films of chitosan and multi-walled carbon nanotubes on a glassy carbon electrode. RSC Adv 2017. [DOI: 10.1039/c6ra26378j] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
A chlorogenic acid sensor based on a chitosan (CS) and multi-walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (GCE) was fabricated via a layer-by-layer (LBL) self-assembly method.
Collapse
Affiliation(s)
- Wenxue Cheng
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
| | - Jianzhi Huang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Cheng Liu
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Qiang Zeng
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Yanli Tong
- Guangdong No. 2 Provincial People's Hospital
- Guangzhou 510317
- People's Republic of China
| | - Lishi Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Faliang Cheng
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
- Dongguan University of Technology
- Dongguan 523808
- People's Republic of China
| |
Collapse
|
14
|
Cheng W, Liu P, Zhang M, Huang J, Cheng F, Wang L. A highly sensitive morin sensor based on PEDT–Au/rGO nanocomposites modified glassy carbon electrode. RSC Adv 2017. [DOI: 10.1039/c7ra08292d] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
A facilely prepared PEDT–Au/rGO/GC sensor shows high sensitivity for electrochemical determination of morin.
Collapse
Affiliation(s)
- Wenxue Cheng
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
- Dongguan University of Technology
- Dongguan 523808
- People's Republic of China
- School of Chemistry and Chemical Engineering
| | - Peng Liu
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
- Dongguan University of Technology
- Dongguan 523808
- People's Republic of China
| | - Min Zhang
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
- Dongguan University of Technology
- Dongguan 523808
- People's Republic of China
| | - Jianzhi Huang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Faliang Cheng
- Guangdong Engineering and Technology Research Center for Advanced Nanomaterials
- Dongguan University of Technology
- Dongguan 523808
- People's Republic of China
| | - Lishi Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| |
Collapse
|
15
|
Huang J, Shen X, Hu Q, Ma Y, Bai S, Yue G, Yu X, Zeng Q, Wang L. High sensitivity simultaneous determination of myricetin and rutin using a polyfurfural film modified glassy carbon electrode. RSC Adv 2016. [DOI: 10.1039/c6ra20459g] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Simultaneous determination of myricetin and rutin by polyfurfural film modified glassy carbon electrode.
Collapse
Affiliation(s)
- Jianzhi Huang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Xiaolei Shen
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Qiong Hu
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Ya Ma
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Silan Bai
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Guoqing Yue
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Xiongtao Yu
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| | - Qiang Zeng
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
- State Key Laboratory of Pulp and Paper Engineering
| | - Lishi Wang
- School of Chemistry and Chemical Engineering
- South China University of Technology
- Guangzhou 510641
- People's Republic of China
| |
Collapse
|