1
|
Gordeeva EO, Roslyakov IV, Leontiev AP, Klimenko AA, Napolskii KS. Uniform arrays of gold nanoelectrodes with tuneable recess depth. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2021; 12:957-964. [PMID: 34621609 PMCID: PMC8450946 DOI: 10.3762/bjnano.12.72] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 08/16/2021] [Indexed: 06/13/2023]
Abstract
Nanoelectrode arrays are much in demand in electroanalytical chemistry, electrocatalysis, and bioelectrochemistry. One of the promising approaches for the preparation of such systems is templated electrodeposition. In the present study, porous anodic alumina templates are used to prepare Au nanoelectrode arrays. Multistage electrodeposition is proposed for the formation of recessed electrodes with the ability to tune the distance between the surface of the porous template and the top surface of the nanoelectrodes. A set of complementary techniques, including chronoamperometry, coulometry, and scanning electron microscopy, are used to characterize the nanoelectrode arrays. The number of active nanoelectrodes is experimentally measured. The pathways to further improve the recessed nanoelectrode arrays based on anodic alumina templates are discussed.
Collapse
Affiliation(s)
- Elena O Gordeeva
- Lomonosov Moscow State University, Leninskie Gory, Moscow 199991, Russia
| | - Ilya V Roslyakov
- Lomonosov Moscow State University, Leninskie Gory, Moscow 199991, Russia
- Kurnakov Institute of General and Inorganic Chemistry RAS, Leninsky av., Moscow 119991, Russia
| | - Alexey P Leontiev
- Lomonosov Moscow State University, Leninskie Gory, Moscow 199991, Russia
| | - Alexey A Klimenko
- Lomonosov Moscow State University, Leninskie Gory, Moscow 199991, Russia
- Institute of Nanotechnology of Microelectronics RAS, Leninsky av., Moscow 115487, Russia
| | - Kirill S Napolskii
- Lomonosov Moscow State University, Leninskie Gory, Moscow 199991, Russia
- Moscow Institute of Physics and Technology, Institutskiy per., Dolgoprudny 141701, Russia
| |
Collapse
|
2
|
Jiang F, Qi L, Song G, Yu HZ. Carbon tape-assisted electrodeposition and characterization of arrayed micro-/nanostructures. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
3
|
Yang X, Wei Y, Du Y, Qi H, Gao Q, Zhang C. Electrogenerated Chemiluminescence Immunoassays on Nanoelectrode Ensembles Platform with Magnetic Microbeads for the Determination of Carbohydrate Antigen. Anal Chem 2020; 92:15837-15844. [PMID: 33269595 DOI: 10.1021/acs.analchem.0c03047] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
This work reports a gold nanoelectrode ensembles (Au-NEE) platform taken as a disposable electrogenerated chemiluminescence (ECL) platform with immunomagnetic microbeads for ECL immunoassays for the first time. The peak-shaped voltammograms were obtained at the Au-NEE, attributed to the total diffusional overlap. The ECL intensity at Au-NEE was 12.9 folds in the Ru(bpy)32+-tri-n-propylamine (TPA) ECL system and 19.6 folds in the luminol-H2O2 system, compared with that at the Au macroelectrode using the normalized active area of the electrodes, mainly attributed to the diffusion overlap of the Au-NEE and the edge effect of the individual gold nanodisks of the Au-NEE. The ECL immunoassay on the Au-NEE platform with magnetic microbeads for the determination of cancer biomarkers was developed. Carbohydrate antigen 19-9 (CA 19-9) was chosen as a model analyte while CA 19-9 antibody on the magnetic microbeads was taken as the capture probe, and ruthenium complex-labeled CA 19-9 antibody was used as the signal probe. A "sandwich" bioconjugates on the magnetic beads were transferred onto the ECL platform, and then the ECL measurements were performed in TPA solution. The developed method showed that the ECL peak intensity was directly in proportion to the concentration of CA 19-9 in the range from 0.5 to 20 U/mL with a limit of detection of 0.4 U/mL. This work demonstrates that the Au-NEE can be employed as a useful disposable ECL platform with the merits of cheapness, low nonspecific adsorption and practical application. The proposed approach will open a new avenue in the point-of-care test for the determination of protein biomarkers.
Collapse
Affiliation(s)
- Xiaolin Yang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| | - Yuxi Wei
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| | - Yujin Du
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| | - Honglan Qi
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| | - Qiang Gao
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| | - Chengxiao Zhang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P.R. China
| |
Collapse
|
4
|
Liu Y, Li X, Chen J, Yuan C. Micro/Nano Electrode Array Sensors: Advances in Fabrication and Emerging Applications in Bioanalysis. Front Chem 2020; 8:573865. [PMID: 33324609 PMCID: PMC7726471 DOI: 10.3389/fchem.2020.573865] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 10/26/2020] [Indexed: 01/24/2023] Open
Abstract
Due to the rapid development of micro/nano manufacturing techniques and the greater understanding in electrochemical principles and methods, micro/nano electrode array sensing has received much attention in recent years, especially in bioanalysis. This review aims to explore recent progress in innovative techniques for the construction of micro/nano electrode array sensor and the unique applications of various types of micro/nano electrode array sensors in biochemical analysis. Moreover, the new area of smart sensing benefited from miniaturization of portable micro/nano electrode array sensors as well as wearable intelligent devices are further discussed.
Collapse
Affiliation(s)
- Yang Liu
- Institute for Advanced Study, Shenzhen University, Shenzhen, China
- College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| | - Xiuting Li
- Institute for Advanced Study, Shenzhen University, Shenzhen, China
| | - Jie Chen
- Institute for Advanced Study, Shenzhen University, Shenzhen, China
| | - Chonglin Yuan
- Institute for Advanced Study, Shenzhen University, Shenzhen, China
| |
Collapse
|
5
|
High-index {hk0} facets platinum concave nanocubes loaded on multiwall carbon nanotubes and graphene oxide nanocomposite for highly sensitive simultaneous detection of dopamine and uric acid. Talanta 2020; 207:120296. [DOI: 10.1016/j.talanta.2019.120296] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 08/21/2019] [Accepted: 08/24/2019] [Indexed: 11/18/2022]
|
6
|
Sasya M, Devi KSS, Babu JK, Balaguru Rayappan JB, Krishnan UM. Metabolic Syndrome-An Emerging Constellation of Risk Factors: Electrochemical Detection Strategies. SENSORS (BASEL, SWITZERLAND) 2019; 20:E103. [PMID: 31878023 PMCID: PMC6982738 DOI: 10.3390/s20010103] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 11/15/2019] [Accepted: 12/11/2019] [Indexed: 02/07/2023]
Abstract
Metabolic syndrome is a condition that results from dysfunction of different metabolic pathways leading to increased risk of disorders such as hyperglycemia, atherosclerosis, cardiovascular diseases, cancer, neurodegenerative disorders etc. As this condition cannot be diagnosed based on a single marker, multiple markers need to be detected and quantified to assess the risk facing an individual of metabolic syndrome. In this context, chemical- and bio-sensors capable of detecting multiple analytes may provide an appropriate diagnostic strategy. Research in this field has resulted in the evolution of sensors from the first generation to a fourth generation of 'smart' sensors. A shift in the sensing paradigm involving the sensing element and transduction strategy has also resulted in remarkable advancements in biomedical diagnostics particularly in terms of higher sensitivity and selectivity towards analyte molecule and rapid response time. This review encapsulates the significant advancements reported so far in the field of sensors developed for biomarkers of metabolic syndrome.
Collapse
Affiliation(s)
- Madhurantakam Sasya
- Department of Molecular Physiology, School of Medicine, Niigata University, Niigata-9518510, Japan;
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed-to-be University, Thanjavur 613401, India; (K.S.S.D.); (J.K.B.); (J.B.B.R.)
- School of Chemical & Biotechnology, SASTRA Deemed-to-be University, Thanjavur 613401, India
| | - K. S. Shalini Devi
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed-to-be University, Thanjavur 613401, India; (K.S.S.D.); (J.K.B.); (J.B.B.R.)
- School of Chemical & Biotechnology, SASTRA Deemed-to-be University, Thanjavur 613401, India
| | - Jayanth K. Babu
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed-to-be University, Thanjavur 613401, India; (K.S.S.D.); (J.K.B.); (J.B.B.R.)
- School of Electrical & Electronics Engineering, SASTRA Deemed-to-be University, Thanjavur 613401, India
| | - John Bosco Balaguru Rayappan
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed-to-be University, Thanjavur 613401, India; (K.S.S.D.); (J.K.B.); (J.B.B.R.)
- School of Electrical & Electronics Engineering, SASTRA Deemed-to-be University, Thanjavur 613401, India
| | - Uma Maheswari Krishnan
- Department of Molecular Physiology, School of Medicine, Niigata University, Niigata-9518510, Japan;
- School of Chemical & Biotechnology, SASTRA Deemed-to-be University, Thanjavur 613401, India
- School of Arts, Science & Humanities, SASTRA Deemed-to-be University, Thanjavur 613401, India
| |
Collapse
|
7
|
Zhao Y, Zhou J, Jia Z, Huo D, Liu Q, Zhong D, Hu Y, Yang M, Bian M, Hou C. In-situ growth of gold nanoparticles on a 3D-network consisting of a MoS2/rGO nanocomposite for simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid. Mikrochim Acta 2019; 186:92. [DOI: 10.1007/s00604-018-3222-7] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Accepted: 12/29/2018] [Indexed: 12/23/2022]
|
8
|
Madhurantakam S, Babu KJ, Rayappan JBB, Krishnan UM. Nanotechnology-based electrochemical detection strategies for hypertension markers. Biosens Bioelectron 2018; 116:67-80. [DOI: 10.1016/j.bios.2018.05.034] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 05/18/2018] [Accepted: 05/21/2018] [Indexed: 12/15/2022]
|
9
|
Recent Advances in Biosensing for Neurotransmitters and Disease Biomarkers using Microelectrodes. ChemElectroChem 2017. [DOI: 10.1002/celc.201600810] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
10
|
Kashyap H, Singh PK, Verma F, Rai VK, Rai A, Singh M. Facile construction of AuNP modulated SDS-wrapped G-TC-tailored electrode for sensitive detection of ascorbic acid. NEW J CHEM 2017. [DOI: 10.1039/c7nj01032j] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
AuNP modulated SDS wrapped G-TC electrode was fabricated for electrocatalytic oxidation of ascorbic acid with high sensitivity of 4017.0 μA mM−1. The LOD was calculated to be 0.07 μM and the sensor was investigated for determination of AcA in real sample (Vit. C tablets) with satisfactory results.
Collapse
Affiliation(s)
- Hemant Kashyap
- Department of Chemistry
- School of Physical Sciences
- Guru Ghasidas Vishwavidyalaya
- Bilaspur-495009
- India
| | - Puneet K. Singh
- School of Physical Science
- Jawaharlal Nehru University
- New Delhi-110027
- India
| | - Fooleswar Verma
- Department of Chemistry
- School of Physical Sciences
- Guru Ghasidas Vishwavidyalaya
- Bilaspur-495009
- India
| | - Vijai K. Rai
- Department of Chemistry
- School of Physical Sciences
- Guru Ghasidas Vishwavidyalaya
- Bilaspur-495009
- India
| | - Ankita Rai
- School of Physical Science
- Jawaharlal Nehru University
- New Delhi-110027
- India
| | - Manorama Singh
- Department of Chemistry
- School of Physical Sciences
- Guru Ghasidas Vishwavidyalaya
- Bilaspur-495009
- India
| |
Collapse
|
11
|
Karimian N, Moretto LM, Ugo P. Nanobiosensing with Arrays and Ensembles of Nanoelectrodes. SENSORS 2016; 17:s17010065. [PMID: 28042840 PMCID: PMC5298638 DOI: 10.3390/s17010065] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Revised: 12/26/2016] [Accepted: 12/27/2016] [Indexed: 01/01/2023]
Abstract
Since the first reports dating back to the mid-1990s, ensembles and arrays of nanoelectrodes (NEEs and NEAs, respectively) have gained an important role as advanced electroanalytical tools thank to their unique characteristics which include, among others, dramatically improved signal/noise ratios, enhanced mass transport and suitability for extreme miniaturization. From the year 2000 onward, these properties have been exploited to develop electrochemical biosensors in which the surfaces of NEEs/NEAs have been functionalized with biorecognition layers using immobilization modes able to take the maximum advantage from the special morphology and composite nature of their surface. This paper presents an updated overview of this field. It consists of two parts. In the first, we discuss nanofabrication methods and the principles of functioning of NEEs/NEAs, focusing, in particular, on those features which are important for the development of highly sensitive and miniaturized biosensors. In the second part, we review literature references dealing the bioanalytical and biosensing applications of sensors based on biofunctionalized arrays/ensembles of nanoelectrodes, focusing our attention on the most recent advances, published in the last five years. The goal of this review is both to furnish fundamental knowledge to researchers starting their activity in this field and provide critical information on recent achievements which can stimulate new ideas for future developments to experienced scientists.
Collapse
Affiliation(s)
- Najmeh Karimian
- Department of Molecular Sciences and Nanosystems, University Ca' Foscari of Venice, Via Torino 155-Mestre, 30172 Venice, Italy.
| | - Ligia M Moretto
- Department of Molecular Sciences and Nanosystems, University Ca' Foscari of Venice, Via Torino 155-Mestre, 30172 Venice, Italy.
| | - Paolo Ugo
- Department of Molecular Sciences and Nanosystems, University Ca' Foscari of Venice, Via Torino 155-Mestre, 30172 Venice, Italy.
| |
Collapse
|