1
|
Yao W, He H, Wang F. CTAB-Modulated Electroplating of Copper Micropillar Arrays for Non-Enzymatic Glucose Sensing with Improved Sensitivity. SENSORS (BASEL, SWITZERLAND) 2024; 24:1603. [PMID: 38475139 DOI: 10.3390/s24051603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/05/2024] [Accepted: 01/07/2024] [Indexed: 03/14/2024]
Abstract
Micropillar array electrodes represent a promising avenue for enhancing detection sensitivity and response current. However, existing methods for depositing electrode materials on micropillar arrays often result in uneven distribution, with the thin sidewall layer being less conductive and prone to corrosion. In addressing this issue, this study introduces electroplating to enhance the copper layer on the sidewall of micropillar array electrodes. These electrodes, fabricated through standard microelectronics processes and electroplating, are proposed for non-enzymatic glucose detection, with the copper layer deposited via electroplating significantly enhancing sensitivity. Initially, the impact of cetyltrimethylammonium bromide (CTAB) concentration as an inhibitor on the surface morphology and sensitivity of the plated layer was investigated. It was discovered that CTAB could decrease surface roughness, hinder the development of large and coarse grains, generate small particles, and boost sensitivity. Compared to the uncoated electrode and plating without CTAB, sensitivity was elevated by a factor of 1.66 and 1.62, respectively. Subsequently, the alterations in plating morphology and detection performance within a range of 0.3 ASD to 3 ASD were examined. Sensitivity demonstrated a tendency to increase initially and then decrease. The electrode plated at 0.75 ASD achieved a maximum sensitivity of 3314 μA·mM-1·cm-2 and a detection limit of 15.9 μM. Furthermore, a potential mechanism explaining the impact of different morphology on detection performance due to CTAB and current density was discussed. It was believed that the presented effective strategy to enhance the sensitivity of micropillar array electrodes for glucose detection would promote the related biomedical detection applications.
Collapse
Affiliation(s)
- Wenhao Yao
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Hu He
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Fuliang Wang
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
2
|
Bharti K, Sadhu KK. Syntheses of metal oxide-gold nanocomposites for biological applications. RESULTS IN CHEMISTRY 2022. [DOI: 10.1016/j.rechem.2022.100288] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
3
|
Patella B, Sortino A, Mazzara F, Aiello G, Drago G, Torino C, Vilasi A, O'Riordan A, Inguanta R. Electrochemical detection of dopamine with negligible interference from ascorbic and uric acid by means of reduced graphene oxide and metals-NPs based electrodes. Anal Chim Acta 2021; 1187:339124. [PMID: 34753568 DOI: 10.1016/j.aca.2021.339124] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/31/2021] [Accepted: 09/28/2021] [Indexed: 01/22/2023]
Abstract
Dopamine is an important neurotransmitter involved in many human biological processes as well as in different neurodegenerative diseases. Monitoring the concentration of dopamine in biological fluids, i.e., blood and urine is an effective way of accelerating the early diagnosis of these types of diseases. Electrochemical sensors are an ideal choice for real-time screening of dopamine as they can achieve fast, portable inexpensive and accurate measurements. In this work, we present electrochemical dopamine sensors based on reduced graphene oxide coupled with Au or Pt nanoparticles. Sensors were developed by co-electrodeposition onto a flexible substrate, and a systematic investigation concerning the electrodeposition parameters (concentration of precursors, deposition time and potential) was carried out to maximize the sensitivity of the dopamine detection. Square wave voltammetry was used as an electrochemical technique that ensured a high sensitive detection in the nM range. The sensors were challenged against synthetic urine in order to simulate a real sample detection scenario where dopamine concentrations are usually lower than 600 nM. Our sensors show a negligible interference from uric and ascorbic acids which did not affect sensor performance. A wide linear range (0.1-20 μm for gold nanoparticles, 0.1-10 μm for platinum nanoparticles) with high sensitivity (6.02 and 7.19 μA μM-1 cm-2 for gold and platinum, respectively) and a low limit of detection (75 and 62 nM for Au and Pt, respectively) were achieved. Real urine samples were also assayed, where the concentrations of dopamine detected aligned very closely to measurements undertaken using conventional laboratory techniques. Sensor fabrication employed a cost-effective production process with the possibility of also being integrated into flexible substrates, thus allowing for the possible development of wearable sensing devices.
Collapse
Affiliation(s)
- Bernardo Patella
- Dipartimento di Ingegneria, Università Degli Studi di Palermo, Italy
| | - Alessia Sortino
- Dipartimento di Ingegneria, Università Degli Studi di Palermo, Italy
| | - Francesca Mazzara
- Dipartimento di Ingegneria, Università Degli Studi di Palermo, Italy
| | - Giuseppe Aiello
- Dipartimento di Ingegneria, Università Degli Studi di Palermo, Italy
| | - Giuseppe Drago
- Dipartimento di Ingegneria, Università Degli Studi di Palermo, Italy
| | - Claudia Torino
- Istituto di Fisiologia Clinica (IFC)-Consiglio Nazionale Delle Ricerche-Reggio Calabria-Italy, Italy
| | - Antonio Vilasi
- Istituto di Fisiologia Clinica (IFC)-Consiglio Nazionale Delle Ricerche-Reggio Calabria-Italy, Italy
| | - Alan O'Riordan
- Nanotechnology Group, Tyndall National Institute, University College Cork, Dyke Prade, Cork, Ireland
| | | |
Collapse
|
4
|
Liu X, Chang AY, Ma Y, Hua L, Yang Z, Wang S. Robust three-dimensional nanotube-in-micropillar array electrodes to facilitate size independent electroporation in blood cell therapy. LAB ON A CHIP 2021; 21:4196-4207. [PMID: 34546271 DOI: 10.1039/d1lc00690h] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Blood is an attractive carrier for plasmid and RNA-based medicine in cell therapy. Electroporation serves as a favorable delivery tool for simple operation, quick internalization, minimum cell culture involvement, and low contamination risk. However, the delivery outcome of electroporation heavily depends on the treated cells such as their type, size, and orientation to the electric field, not ideal for highly heterogeneous blood samples. Herein, a new electroporation system was developed towards effective transfection to cells in blood regardless of their large diversity. By coupling replica molding and infiltration-coating processes, we successfully configured a three-dimensional electrode comprised of a polymer micropillar array on which carbon nanotubes (CNTs) are partially embedded. During electroporation, cells sag between micropillars and deform to form a conformal contact with their top and side surfaces. The implanted CNTs not only provide a robust conductive coating for polymer micropattern but also have their protruded ends face the cell membrane vertically everywhere with maximum transmembrane potential. Regardless of their largely varied sizes and random dispersion, both individual blood cell type and whole blood samples were effectively transfected with plasmid DNA (85% after 24 h and 95% after 72 h, or 2.5-3.0 folds enhancement). High-dose RNA probes were also introduced, which regulate better the expression levels of exogenous and endogenous genes in blood cells. Besides its promising performance on non-viral delivery routes to cell-related studies and therapy, the involved new fabrication method also provides a convenient and effective way to construct flexible electronics with stable micro/nano features on the surface.
Collapse
Affiliation(s)
- Xuan Liu
- Center for Biomedical Engineering and Rehabilitations, Institute for Micromanufacturing, Louisiana Tech University, PO Box 10137, Ruston, LA, 71272, USA.
| | - An-Yi Chang
- Center for Biomedical Engineering and Rehabilitations, Institute for Micromanufacturing, Louisiana Tech University, PO Box 10137, Ruston, LA, 71272, USA.
| | - Yifan Ma
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.
| | - Liping Hua
- Center for Biomedical Engineering and Rehabilitations, Institute for Micromanufacturing, Louisiana Tech University, PO Box 10137, Ruston, LA, 71272, USA.
| | - Zhaogang Yang
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.
| | - Shengnian Wang
- Center for Biomedical Engineering and Rehabilitations, Institute for Micromanufacturing, Louisiana Tech University, PO Box 10137, Ruston, LA, 71272, USA.
| |
Collapse
|
5
|
Chang AY, Siddiqui S, Arumugam PU. Nafion and Multiwall Carbon Nanotube Modified Ultrananocrystalline Diamond Microelectrodes for Detection of Dopamine and Serotonin. MICROMACHINES 2021; 12:523. [PMID: 34066363 PMCID: PMC8148102 DOI: 10.3390/mi12050523] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 04/28/2021] [Accepted: 05/03/2021] [Indexed: 01/21/2023]
Abstract
Neurochemicals play a critical role in the function of the human brain in healthy and diseased states. Here, we have investigated three types of microelectrodes, namely boron-doped ultrananocrystalline diamond (BDUNCD), nafion-modified BDUNCD, and nafion-multi-walled carbon nanotube (MWCNT)-modified BDUNCD microelectrodes for long-term neurochemical detection. A ~50 nm-thick nafion-200-nm-thick MWCNT-modified BDUNCD microelectrode provided an excellent combination of sensitivity and selectivity for the detection of dopamine (DA; 6.75 μA μM-1 cm-2) and serotonin (5-HT; 4.55 μA μM-1 cm-2) in the presence of excess amounts of ascorbic acid (AA), the most common interferent. Surface stability studies employing droplet-based microfluidics demonstrate rapid response time (<2 s) and low limits of detection (5.4 ± 0.40 nM). Furthermore, we observed distinguishable DA and 5-HT current peaks in a ternary mixture during long-term stability studies (up to 9 h) with nafion-MWCNT-modified BDUNCD microelectrodes. Reduced fouling on the modified BDUNCD microelectrode surface offers significant advantages for their use in long-term neurochemical detection as compared to those of prior-art microelectrodes.
Collapse
Affiliation(s)
- An-Yi Chang
- Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA;
- Center for Biomedical Engineering and Rehabilitation Science (CBERS), Louisiana Tech University, Ruston, LA 71272, USA
| | - Shabnam Siddiqui
- Department of Chemistry and Physics, Louisiana State University Shreveport, Shreveport, LA 71115, USA;
| | - Prabhu U. Arumugam
- Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA;
- Center for Biomedical Engineering and Rehabilitation Science (CBERS), Louisiana Tech University, Ruston, LA 71272, USA
| |
Collapse
|