1
|
Arul P, Nandhini C, Huang ST, Gowthaman NSK, Huang CH. Tailoring of peroxidase mimetics bifunctional nanocomposite: Dual mode electro-spectroscopic screening of cholesterol and hydrogen peroxide in real food samples and live cells. Food Chem 2023; 414:135747. [PMID: 36841102 DOI: 10.1016/j.foodchem.2023.135747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/06/2023] [Accepted: 02/16/2023] [Indexed: 02/22/2023]
Abstract
A simple and rapid screening of biomarkers in clinical and food matrices is urgently needed to diagnose cardiovascular diseases. The cholesterol (Chol) and hydrogen peroxide (H2O2) are critical bio-indicators, which require more inventive detection techniques to be applied to real food, and bio-samples. In this study, a robust dual sensor was developed for Chol and H2O2 using hybrid catalyst. Bovine serum albumin (BSA)-capped nanocatalyst was potentially catalyzed 3,3',5,5'-tetramethylbenzidine (TMB), and H2O2. The enzymatic nanoelectrocatalyst delivered a wide range of signaling concentrations from 250 nM to 3.0 mM and 100 nM to 10 mM, limit of detection (LOD) of 53.2 nM and 18.4 nM for Chol and H2O2. The cholesterol oxidase-BSA-AuNPs-metal-free organic framework (ChOx-BSA-AuNPs-MFOF) based electrode surface effectively operated in live-cells and real-food samples. The enzymatic sensor exhibits adequate recovery of real-food samples (96.96-99.44%). Finally, the proposed system is a suitable choice for the potential applications of Chol and H2O2 in clinical and food chemistry.
Collapse
Affiliation(s)
- P Arul
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC.
| | - C Nandhini
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC.
| | - Sheng-Tung Huang
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC.
| | - N S K Gowthaman
- School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor, Malaysia.
| | - Chih-Hung Huang
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC.
| |
Collapse
|
2
|
Vinoth S, Wang SF. Lanthanum vanadate-based carbon nanocomposite as an electrochemical probe for amperometric detection of theophylline in real food samples. Food Chem 2023; 427:136623. [PMID: 37364311 DOI: 10.1016/j.foodchem.2023.136623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 05/25/2023] [Accepted: 06/11/2023] [Indexed: 06/28/2023]
Abstract
Theophylline (THP) is an emerging drug for chronic obstructive pulmonary disease whose side effects can be greatly affected by caffeine-containing real foods. Because an overdose of this substance can cause respiratory and neurological damage, producing a fast and accurate analytical procedure is critical. Based on a cutting-edge hybrid nanocomposite, this study was used to construct an electrochemical sensor for the accurate detection of THP. Spectroscopy and morphological investigation supported the easy synthesis of tetragonal-LaVO4 (t-LV) nanopellets and LV@CNF hybrid nanocomposite. To detect THP, a highly dispersed LV@CNF nanocomposite was modified on a glassy carbon electrode as a sensing substrate. By amperometric technique, the sensor shows a wide linear range of 0.01-1070 μM, low limit of detection (2.63 nM), and sensitivity (0.228 μA μM-1 cm-2). Finally, the current technique was successfully used to identify THP in real food samples (chocolate, coffee and black tea).
Collapse
Affiliation(s)
- Subramaniyan Vinoth
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung-Hsiao East Rd., Taipei 106, Taiwan
| | - Sea-Fue Wang
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung-Hsiao East Rd., Taipei 106, Taiwan.
| |
Collapse
|
3
|
Shahbazi-Derakhshi P, Mahmoudi E, Majidi MM, Sohrabi H, Amini M, Majidi MR, Niaei A, Shaykh-Baygloo N, Mokhtarzadeh A. An Ultrasensitive miRNA-Based Genosensor for Detection of MicroRNA 21 in Gastric Cancer Cells Based on Functional Signal Amplifier and Synthesized Perovskite-Graphene Oxide and AuNPs. BIOSENSORS 2023; 13:172. [PMID: 36831939 PMCID: PMC9953341 DOI: 10.3390/bios13020172] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/12/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
In the present research work, the state-of-art label-free electrochemical genosensing platform was developed based on the hybridization process in the presence of [Fe(CN)6]3-/4- as an efficient redox probe for sensitive recognition of the miRNA-21 in human gastric cell lines samples. To attain this aim, perovskite nanosheets were initially synthesized. Afterward, the obtained compound was combined with the graphene oxide resulting in an effective electrochemical modifier, which was dropped on the surface of the Au electrode. Then, AuNPs (Gold Nano Particles) have been electrochemically-immobilized on perovskite-graphene oxide/Au-modified electrode surface through the chronoamperometry (CA) technique. Finally, a self-assembling monolayer reaction of ss-capture RNA ensued by the thiol group at the end of the probe with AuNPs on the modified electrode surface. miRNA-21 has been cast on the Au electrode surface to apply the hybridization process. To find out the effectiveness of the synthesized modifier agent, the electrochemical behavior of the modified electrode has been analyzed through DPV (differential pulse voltammetry) and CV (cyclic voltammetry) techniques. The prepared biomarker-detection bioassay offers high sensitivity and specificity, good performance, and appropriate precision and accuracy for the highly-sensitive determination of miRNA-21. Different characterization methods have been used, such as XRD, Raman, EDS, and FE-SEM, for morphological characterization and investigation of particle size. Based on optimal conditions, the limit of detection and quantification have been acquired at 2.94 fM and 8.75 fM, respectively. Furthermore, it was possible to achieve a wide linear range which is between 10-14 and 10-7 for miRNA-21. Moreover, the selectivity of the proposed biosensing assay was investigated through its potential in the detection of one, two, and three-base mismatched sequences. Moreover, it was possible to investigate the repeatability and reproducibility of the related bio-assay. To evaluate the hybridization process, it is important that the planned biomarker detection bio-assay could be directly re-used and re-generated.
Collapse
Affiliation(s)
- Payam Shahbazi-Derakhshi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 5166-616471, Iran
- Department of Biology, Faculty of Science, Urmia University, Urmia 5756-151818, Iran
- Immunology Research Center, Medical Science University of Tabriz, Tabriz 5166-15731, Iran
| | - Elham Mahmoudi
- Catalyst and Reactor Research Lab, Department of Chemical & Petroleum Engineering, University of Tabriz, Tabriz 5166-616471, Iran
| | - Mir Mostafa Majidi
- Catalyst and Reactor Research Lab, Department of Chemical & Petroleum Engineering, University of Tabriz, Tabriz 5166-616471, Iran
- Department of Chemical Engineering, Amirkabir University of Technology, Tehran 1591-634311, Iran
| | - Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 5166-616471, Iran
| | - Mohammad Amini
- Immunology Research Center, Medical Science University of Tabriz, Tabriz 5166-15731, Iran
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 5166-616471, Iran
| | - Aligholi Niaei
- Catalyst and Reactor Research Lab, Department of Chemical & Petroleum Engineering, University of Tabriz, Tabriz 5166-616471, Iran
| | - Nima Shaykh-Baygloo
- Department of Biology, Faculty of Science, Urmia University, Urmia 5756-151818, Iran
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Medical Science University of Tabriz, Tabriz 5166-15731, Iran
| |
Collapse
|
4
|
Xiao J, Shi S, Yao L, Feng J, Zuo J, He Q. Fast and Ultrasensitive Electrochemical Detection for Antiviral Drug Tenofovir Disoproxil Fumarate in Biological Matrices. BIOSENSORS 2022; 12:1123. [PMID: 36551090 PMCID: PMC9775179 DOI: 10.3390/bios12121123] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/23/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
Tenofovir disoproxil fumarate (TDF) is an antiretroviral medication with significant curative effects, so its quantitative detection is important for human health. At present, there are few studies on the detection of TDF by electrochemical sensors. This work can be a supplement to the electrochemical detection of TDF. Moreover, bare electrodes are susceptible to pollution, and have high overvoltage and low sensitivity, so it is crucial to find a suitable electrode material. In this work, zirconium oxide (ZrO2) that has a certain selectivity to phosphoric acid groups was synthesized by a hydrothermal method with zirconyl chloride octahydrate as the precursor. A composite modified glassy carbon electrode for zirconium oxide-chitosan-multiwalled carbon nanotubes (ZrO2-CS-MWCNTs/GCE) was used for the first time to detect the TDF, and achieved rapid, sensitive detection of TDF with a detection limit of sub-micron content. The ZrO2-CS-MWCNTs composite was created using sonication of a mixture of ZrO2 and CS-MWCNTs solution. The composite was characterized using scanning electron microscopy (SEM) and cyclic voltammetry (CV). Electrochemical analysis was performed using differential pulse voltammetry (DPV). Compared with single-material electrodes, the ZrO2-CS-MWCNTs/GCE significantly improves the electrochemical sensing of TDF due to the synergistic effect of the composite. Under optimal conditions, the proposed method has achieved good results in linear range (0.3~30 μM; 30~100 μM) and detection limit (0.0625 μM). Moreover, the sensor has the merits of simple preparation, good reproducibility and good repeatability. The ZrO2-CS-MWCNTs/GCE has been applied to the determination of TDF in serum and urine, and it may be helpful for potential applications of other substances with similar structures.
Collapse
Affiliation(s)
- Jingyun Xiao
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
- Geriatric Rehabilitation Department, Zhuzhou People’s Hospital, Zhuzhou 421007, China
| | - Shuting Shi
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Liangyuan Yao
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
| | - Jinxia Feng
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Jinsong Zuo
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Quanguo He
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
- Geriatric Rehabilitation Department, Zhuzhou People’s Hospital, Zhuzhou 421007, China
| |
Collapse
|