1
|
Macías M, Jiménez JA, Rodríguez de San Miguel E, Moreira-Santos M. Appraisal on the role of passive sampling for more integrative frameworks on the environmental risk assessment of contaminants. CHEMOSPHERE 2023; 324:138352. [PMID: 36898436 DOI: 10.1016/j.chemosphere.2023.138352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/20/2023] [Accepted: 03/07/2023] [Indexed: 06/18/2023]
Abstract
Over time multiple lines of research have been integrated as important components of evidence for assessing the ecological quality status of water bodies within the framework of Environmental Risk Assessment (ERA) approaches. One of the most used integrative approaches is the triad which combines, based on the weight-of-evidence, three lines of research, the chemical (to identify what is causing the effect), the ecological (to identify the effects at the ecosystem level) and the ecotoxicological (to ascertain the causes of ecological damage), with the agreement between the different lines of risk evidence increasing the confidence in the management decisions. Although the triad approach has proven greatly strategic in ERA processes, new assessment (and monitoring) integrative and effective tools are most welcome. In this regard, the present study is an appraisal on the boost that passive sampling, by allowing to increase information reliability, can give within each of the triad lines of evidence, for more integrative ERA frameworks. In parallel to this appraisal, examples of works that used passive samplers within the triad are presented providing support for the use of these devices in a complementary form to generate holistic information for ERA and ease the process of decision-making.
Collapse
Affiliation(s)
- Mariana Macías
- Departamento de Química Analítica, Facultad de Química, UNAM, Ciudad Universitaria, 04510, Cd.Mx., Mexico
| | - Jesús A Jiménez
- Departamento de Química Analítica, Facultad de Química, UNAM, Ciudad Universitaria, 04510, Cd.Mx., Mexico
| | | | - Matilde Moreira-Santos
- CFE-Centre for Functional Ecology - Science for People and the Planet, Associate Laboratory TERRA, Department of Life Sciences, University of Coimbra, Calçada Martim de Freitas, 3000-456, Coimbra, Portugal
| |
Collapse
|
2
|
González-Albarrán R, de Gyves J, Rodríguez de San Miguel E. Influence of some physicochemical parameters on the passive sampling of copper (II) from aqueous medium using a polymer inclusion membrane device. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 258:113474. [PMID: 31859125 DOI: 10.1016/j.envpol.2019.113474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/02/2019] [Accepted: 10/22/2019] [Indexed: 06/10/2023]
Abstract
Recently polymer inclusion membranes (PIMs) have been proposed as materials for passive sampling, nonetheless a theoretical base to describe the mass transfer process through those materials, under such conditions of monitoring, has not been elucidated. Under the assumption that: (i) the transport of the metal ion occurs at steady state conditions, (ii) the concentration gradients are linear, and (iii) the kinetics of the chemical reactions in the extraction process on the membrane are elemental; an equation for the passive sampling of copper (II) using a PIM system containing Kelex-100 as carrier is derived. The prediction capacity of this sampler under different conditions of temperature, metal concentration, flow velocity, ionic strength and pH is analyzed as well. Among the dependencies of the PIM on the physicochemical conditions, effects of concentration, temperature and flow velocity tend to increment copper (II) flux across the membrane, being the parameter temperature the one with the most pronounced effect at T ≥ 30 °C. Ionic strength had no great effect on passive sampler response, however the sampler is dependent on the acidity of the medium. The comparable metal ion concentrations estimated from the PIM sampler to those obtained by direct measurements of the sampling medium suggest that PIMs can be robust materials when used as passive sampler devices.
Collapse
Affiliation(s)
- René González-Albarrán
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510, CdMx, Mexico
| | - Josefina de Gyves
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510, CdMx, Mexico
| | - Eduardo Rodríguez de San Miguel
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510, CdMx, Mexico.
| |
Collapse
|
3
|
González-Álvarez RJ, Pinto JJ, López-López JA, Mendiguchía C, Moreno C. Selective solvent bar micro-extraction as a single-step approach for the measurement of Cu fractions in seawater. Anal Bioanal Chem 2020; 412:1863-1870. [PMID: 31975154 DOI: 10.1007/s00216-020-02433-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 01/10/2020] [Accepted: 01/16/2020] [Indexed: 12/17/2022]
Abstract
Hollow fibre-supported liquid membrane was used for Cu fractionation in marine waters, using di-2-pyridylketone benzoylhydrazone (dPKBH) as a carrier due to its capacity to transport dissolved inorganic Cu at natural seawater pH. Optimized conditions were dPKBH (0.5 mmol L-1), HNO3 (0.5 mol L-1) as acceptor agent, extraction time of 120 min and stirring speed of 800 rpm. Additionally, the selectivity of the method for the extraction of the inorganic Cu fraction was validated by comparing the experimental results with theoretical data, and a mathematical model was obtained for estimation of Cu linked to dissolved organic matter. The method was applied for the measurement of Cu fractions in real seawater samples. Results were successfully compared with the reference material BCR 403 and recovery analysis in waters from the Gulf of Cádiz, showing that it could be used as a simple approach for the study of different Cu fractions in marine waters. Graphical abstract.
Collapse
Affiliation(s)
- Rafael J González-Álvarez
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto de Investigación Marina (INMAR), University of Cádiz, Puerto Real, 11510, Cádiz, Spain
| | - Juan J Pinto
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto de Investigación Marina (INMAR), University of Cádiz, Puerto Real, 11510, Cádiz, Spain
| | - José A López-López
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto de Investigación Marina (INMAR), University of Cádiz, Puerto Real, 11510, Cádiz, Spain.
| | - Carolina Mendiguchía
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto de Investigación Marina (INMAR), University of Cádiz, Puerto Real, 11510, Cádiz, Spain
| | - Carlos Moreno
- Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto de Investigación Marina (INMAR), University of Cádiz, Puerto Real, 11510, Cádiz, Spain
| |
Collapse
|
4
|
Design of a Hollow Fiber Supported Liquid Membrane System for Zn Speciation in Natural Waters. MEMBRANES 2018; 8:membranes8040088. [PMID: 30262757 PMCID: PMC6316088 DOI: 10.3390/membranes8040088] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 09/16/2018] [Accepted: 09/25/2018] [Indexed: 11/17/2022]
Abstract
A supported liquid membrane-hollow fiber system (HFSLM) has been developed to determine zinc speciation in aquatic environments. The liquid membrane consisted of an organic solution of bis-(2-ethylhexyl)phosphoric acid (D2EHPA) impregnated in the microporous of a polypropylene hollow fiber. The membrane contacted both the donor solution, that contained the metal and the stripping solution, placed in the lumen of the hollow fiber, where the metal was preconcentrated. Different parameters affecting the Zn2+ transport efficiency have been evaluated such as the composition of both the donor and stripping solutions as well as the membrane phase. Extraction and transport efficiencies of free Zn(II) higher than 90% were obtained with a liquid membrane consisting of a 0.1 M D2EHPA solution in dodecane and a 0.1 M HNO3 solution as the stripping phase. The developed HFSLM was used to study the effect of different ligands (EDTA and citric acid) in the donor phase of Zn(II) transport and to investigate the selectivity of the membrane towards Zn when other metals were also present. Finally, the HFSLM system was successfully applied to estimate the free Zn(II) concentrations in three water samples from a mining area. Moreover, the HFSLM system facilitates the analytical determination of trace Zn(II) levels allowing the achievement of enrichment factors of around 700 in the stripping phase.
Collapse
|
5
|
Vera R, Fontàs C, Galceran J, Serra O, Anticó E. Polymer inclusion membrane to access Zn speciation: Comparison with root uptake. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 622-623:316-324. [PMID: 29220759 DOI: 10.1016/j.scitotenv.2017.11.316] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2017] [Revised: 11/27/2017] [Accepted: 11/27/2017] [Indexed: 06/07/2023]
Abstract
Metal speciation studies can be performed with a new technique based on a functionalized membrane. The estimation of not only the total amount of metal, but also the metal available to living organisms is very important. In this context, we have investigated the use of a polymer inclusion membrane (PIM) in a new tool for the determination of free metal ion concentration. In order to check the usefulness of PIM devices in metal speciation studies and metal availability to potato plants (Solanum tuberosum), Zn has been chosen as a case study. The PIM designed for Zn transport uses polyvinyl chloride (PVC) as polymer and di-(2-ethylhexyl) phosphoric acid (D2EHPA) as carrier, with 0.01M nitric acid in the receiving solution. The stability of the PIM has been demonstrated and good linearity of PIM-device fluxes (JPIM) with free metal concentration was observed for total metal concentrations ranging from 3μM up to 70μM. The presence of different ligands, such as ethylenediaminetetraacetic acid (EDTA), humic acid (HA) and citrate, greatly influences the measured JPIM because the formation of metal complexes in the donor phase decreases the free Zn concentration in the sample. Good correlation has been found when comparing PIM fluxes and metal accumulation in potato plants roots in the presence of EDTA. But, the root uptake did not change when adding citrate and HA to the hydroponic medium, so the uptake does not always follows the Free Ion Activity Model (FIAM). These ligands might induce physiological changes in the roots and enhance metal uptake.
Collapse
Affiliation(s)
- Ruben Vera
- Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003 Girona, Spain
| | - Clàudia Fontàs
- Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003 Girona, Spain
| | - Josep Galceran
- Departament de Química, Universitat de Lleida and AGROTECNIO, Rovira Roure 191, 25198 Lleida, Spain
| | - Olga Serra
- Laboratori del Suro, Biology Department, C/ Maria Aurèlia Capmany, 69, 17003 Girona, Spain
| | - Enriqueta Anticó
- Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003 Girona, Spain.
| |
Collapse
|