1
|
Rufo JC, Annesi-Maesano I, Carreiro-Martins P, Moreira A, Sousa AC, Pastorinho MR, Neuparth N, Taborda-Barata L. Issue 2 - "Update on adverse respiratory effects of indoor air pollution" Part 1): Indoor air pollution and respiratory diseases: A general update and a Portuguese perspective. Pulmonology 2024; 30:378-389. [PMID: 37230882 DOI: 10.1016/j.pulmoe.2023.03.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 03/27/2023] [Accepted: 03/28/2023] [Indexed: 05/27/2023] Open
Abstract
OBJECTIVE To quantify the impact of different air pollutants on respiratory health based on robust estimates based on international data and to summarise the evidence of associations between indoor exposure to those pollutants and respiratory morbidity in the Portuguese population. RESULTS Several systematic reviews and meta-analyses (MA) at the world level demonstrate the impact of indoor air quality on respiratory health, with indoor particulate matter and gasses exerting a significant effect on the airways. Volatile organic compounds (VOC) have been related to asthma and lung cancer. However, only meta-analyses on biomass use allowed documentation of long-term respiratory effects. While early publications concerning Portuguese-based populations mainly focused on indoor exposure to environmental tobacco smoke, later studies relocated the attention to relevant exposure environments, such as day care buildings, schools, residences and nursing homes. Looking at the pooled effects from the reviewed studies, high levels of carbon dioxide and particulate matter in Portuguese buildings were significantly associated with asthma and wheezing, with VOC and fungi showing a similar effect in some instances. CONCLUSIONS Despite the significant reduction of indoor air pollution effects after the 2008 indoor smoking prohibition in public buildings, studies show that several indoor air parameters are still significantly associated with respiratory health in Portugal. The country shares the worldwide necessity of standardisation of methods and contextual data to increase the reach of epidemiological studies on household air pollution, allowing a weighted evaluation of interventions and policies focused on reducing the associated respiratory morbidity.
Collapse
Affiliation(s)
- J C Rufo
- EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal; Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Universidade do Porto, Rua das Taipas, n° 135, 4050-600 Porto, Portugal
| | - I Annesi-Maesano
- Institute Desbrest of Epidemiology and Public Health, University of Montpellier and INSERM, Montpellier, France
| | - P Carreiro-Martins
- Comprehensive Health Research Center (CHRC), NOVA Medical School, Faculdade de Ciências Médicas, NMS, FCM, Universidade NOVA de Lisboa, Lisboa, Portugal; Immunoallergology Service, Dona Estefânia Hospital, Centro Hospitalar e Universitário de Lisboa Central (CHULC), Lisbon, Portugal.
| | - A Moreira
- EPIUnit - Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal; Laboratório para a Investigação Integrativa e Translacional em Saúde Populacional (ITR), Universidade do Porto, Rua das Taipas, n° 135, 4050-600 Porto, Portugal; Serviço de Imunoalergologia, Centro Hospitalar Universitário São João, Porto, Portugal; Basic and Clinical Immunology Unit, Department of Pathology, Faculty of Medicine, University of Porto, Porto, Portugal
| | - A C Sousa
- Comprehensive Health Research Centre (CHRC) and Department of Biology, University of Évora, Évora, Portugal; NuESA-Health and Environment Study Unit, Faculty of Health Sciences, University of Beira Interior, Covilhã, Portugal
| | - M R Pastorinho
- NuESA-Health and Environment Study Unit, Faculty of Health Sciences, University of Beira Interior, Covilhã, Portugal; Comprehensive Health Research Centre (CHRC) and Department of Medical and Health Sciences, University of Évora, Évora, Portugal
| | - N Neuparth
- Comprehensive Health Research Center (CHRC), NOVA Medical School, Faculdade de Ciências Médicas, NMS, FCM, Universidade NOVA de Lisboa, Lisboa, Portugal; Immunoallergology Service, Dona Estefânia Hospital, Centro Hospitalar e Universitário de Lisboa Central (CHULC), Lisbon, Portugal
| | - L Taborda-Barata
- NuESA-Health and Environment Study Unit, Faculty of Health Sciences, University of Beira Interior, Covilhã, Portugal; UBIAir-Clinical & Experimental Lung Centre, University of Beira Interior, CACB - Clinical Academic Centre of Beiras, Covilhã, Portugal; CICS-Health Sciences Research Centre, University of Beira Interior, CACB - Clinical Academic Centre of Beiras, Covilhã, Portugal; Immunoallergology Service, Centro Hospitalar Universitário Cova da Beira, CACB - Clinical Academic Centre of Beiras, Covilhã, Portugal
| |
Collapse
|
2
|
Tomazin R, Matos T. Mycological Methods for Routine Air Sampling and Interpretation of Results in Operating Theaters. Diagnostics (Basel) 2024; 14:288. [PMID: 38337804 PMCID: PMC10855394 DOI: 10.3390/diagnostics14030288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024] Open
Abstract
Many infectious diseases are transmitted via the air and are, therefore, particularly difficult to combat. These infections include various invasive mycoses caused by molds. The usual route of infection is the inhalation of conidia. In hospitals, infection can also occur through the deposition of conidia in otherwise sterile anatomical sites during surgical and other invasive procedures. Therefore, knowledge of airborne mold concentrations can lead to measures to protect patients from fungal infections. The literature on this topic contains insufficient and sometimes ambiguous information. This is evidenced by the fact that there are no international recommendations or guidelines defining the methodology of air sampling and the interpretation of the results obtained. Surgical departments, intensive care units and medical mycology laboratories are, therefore, left to their own devices, leading to significant differences in the implementation of mycological surveillance in hospitals. The aim of this mini-review is to provide an overview of the current methods of air sampling and interpretation of results used in medical mycology laboratories.
Collapse
Affiliation(s)
| | - Tadeja Matos
- Institute of Microbiology and Immunology, Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia;
| |
Collapse
|
3
|
Viegas C, Dias M, Viegas S. Electrostatic Dust Cloth: A Useful Passive Sampling Method When Assessing Exposure to Fungi Demonstrated in Studies Developed in Portugal (2018–2021). Pathogens 2022; 11:pathogens11030345. [PMID: 35335669 PMCID: PMC8955157 DOI: 10.3390/pathogens11030345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/23/2022] [Accepted: 03/10/2022] [Indexed: 11/16/2022] Open
Abstract
Electrostatic dust cloths (EDC) have been widely used for microbiologic contamination assessment in different indoor and occupational environments. This paper reviews sixteen studies performed in Portugal between 2018 and 2021 for evaluating the exposure to microbiological agents and focusing on fungi using EDC as a passive sampling method. The findings suggest that EDC can be applied as a screening method for particulate matter-exposure assessment and as a complementary method to characterize microbial exposures in occupational environments. Overall, EDC should be included, side by side with other sampling methods, in sampling campaigns focused on exposure assessments due to the advantages such as the straightforward extraction protocol favoring the employment of different assays, which allows us to assess exposure to a wide range of microbial agents, and presents higher accuracy regarding the fungal diversity.
Collapse
Affiliation(s)
- Carla Viegas
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1990-096 Lisbon, Portugal; (M.D.); (S.V.)
- Public Health Research Centre, NOVA National School of Public Health, Universidade NOVA de Lisboa, 1099-085 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), NOVA Medical School, Universidade NOVA de Lisboa, 1169-056 Lisbon, Portugal
- Correspondence:
| | - Marta Dias
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1990-096 Lisbon, Portugal; (M.D.); (S.V.)
- Public Health Research Centre, NOVA National School of Public Health, Universidade NOVA de Lisboa, 1099-085 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), NOVA Medical School, Universidade NOVA de Lisboa, 1169-056 Lisbon, Portugal
| | - Susana Viegas
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1990-096 Lisbon, Portugal; (M.D.); (S.V.)
- Public Health Research Centre, NOVA National School of Public Health, Universidade NOVA de Lisboa, 1099-085 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), NOVA Medical School, Universidade NOVA de Lisboa, 1169-056 Lisbon, Portugal
| |
Collapse
|
4
|
Indoor Air Quality in Healthcare Units—A Systematic Literature Review Focusing Recent Research. SUSTAINABILITY 2022. [DOI: 10.3390/su14020967] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The adequate assessment and management of indoor air quality in healthcare facilities is of utmost importance for patient safety and occupational health purposes. This study aims to identify the recent trends of research on the topic through a systematic literature review following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology. A total of 171 articles published in the period 2015–2020 were selected and analyzed. Results show that there is a worldwide growing research interest in this subject, dispersed in a wide variety of scientific journals. A textometric analysis using the IRaMuTeQ software revealed four clusters of topics in the sampled articles: physicochemical pollutants, design and management of infrastructures, environmental control measures, and microbiological contamination. The studies focus mainly on hospital facilities, but there is also research interest in primary care centers and dental clinics. The majority of the analyzed articles (85%) report experimental data, with the most frequently measured parameters being related to environmental quality (temperature and relative humidity), microbiological load, CO2 and particulate matter. Non-compliance with the WHO guidelines for indoor air quality is frequently reported. This study provides an overview of the recent literature on this topic, identifying promising lines of research to improve indoor air quality in healthcare facilities.
Collapse
|
5
|
Cytotoxicity of Aspergillus Section Fumigati Isolated from Health Care Environments. J Fungi (Basel) 2021; 7:jof7100839. [PMID: 34682260 PMCID: PMC8539694 DOI: 10.3390/jof7100839] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 10/05/2021] [Accepted: 10/05/2021] [Indexed: 01/04/2023] Open
Abstract
This study analyzed 57 Aspergillus section Fumigati (AF) isolates collected by active and passive sampling (N = 450) in several health care facilities and from biological sampling of health care workers (N = 25) and controls (N = 22) in Portugal. All isolates were cultured in different media and screened for azole resistance. Cytotoxicity was assessed for 40 isolates in lung epithelial cells and kidney cells using the MTT assay. Aspergillus section Fumigati was prevalent in the health care facilities and in nasal swabs from health care workers and controls. All AF isolates reduced cell viability and presented medium to high cytotoxicity, with cytotoxicity being significantly higher in A549 lung epithelial cells. The cytotoxicity of isolates from air and nasal swab samples suggested the inhalation route as a risk factor. Notably, 42% of AF isolates exhibited a pattern of reduced susceptibility to some of the most used antifungals available for the treatment of patients infected with these fungi. In sum, the epidemiology and clinical relevance of Aspergillus section Fumigati should continue to be addressed. A deeper understanding of the mechanisms underlying Aspergillus-mediated cytotoxicity is necessary.
Collapse
|
6
|
Aspergillus Section Fumigati in Firefighter Headquarters. Microorganisms 2021; 9:microorganisms9102112. [PMID: 34683433 PMCID: PMC8541501 DOI: 10.3390/microorganisms9102112] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 09/28/2021] [Accepted: 10/05/2021] [Indexed: 01/05/2023] Open
Abstract
Background: Aspergillus section Fumigati is one of the Aspergillus sections more frequently related to respiratory symptoms and by other health outcomes. This study aimed to characterize Aspergillus section Fumigati distribution in eleven firefighter headquarters (FFHs) to obtain an accurate occupational exposure assessment. Methods: A sampling approach protocol was performed using active (impaction method) and passive sampling methods (floor surfaces swabs, electrostatic dust collectors (EDCs), and settled dust). All samples were analysed by culture-based methods and passive sampling was used for molecular detection of Aspergillus section Fumigati. Results: Of all the matrices, the highest counts of Aspergillus sp. were obtained on settled dust filters (3.37% malt extract agar—MEA, 19.09% dichloran glycerol—DG18) followed by cleaning cloths (1.67% MEA; 7.07% DG18). Among the Aspergillus genus, the Fumigati section was predominant in Millipore and EDC samples in MEA (79.77% and 28.57%, respectively), and in swabs and settled dust filters in DG18 (44.76% and 30%, respectively). The Fumigati section was detected more frequently in DG18 (33.01%) compared to MEA (0.33%). The Fumigati section was observed in azole supplemented media (itraconazole and voriconazole) in several passive sampling methods employed and detected by qPCR in almost all passive samples, with EDCs being the matrix with the highest prevalence (n = 61; 67.8%). Conclusion: This study confirms that Aspergillus sp. is widespread and the Fumigati section is present in all FFHs. The presence of fungi potentially resistant to azoles in the FFHs was also observed. Further studies are needed to identify the best corrective and preventive measures to avoid this section contamination in this specific occupational environment.
Collapse
|
7
|
Monteiro A, Almeida B, Paciência I, Cavaleiro Rufo J, Ribeiro E, Carolino E, Viegas C, Uva AS, Verde SC. Bacterial Contamination in Health Care Centers: Differences between Urban and Rural Settings. ATMOSPHERE 2021; 12:450. [DOI: 10.3390/atmos12040450] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the majority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria.
Collapse
Affiliation(s)
- Ana Monteiro
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1600-560 Lisbon, Portugal
- Escola Nacional de Saúde Pública, Universidade NOVA de Lisboa, 1600-560 Lisbon, Portugal
- Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, 1600-560 Lisbon, Portugal
| | - Beatriz Almeida
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1600-560 Lisbon, Portugal
| | - Inês Paciência
- Portugal & Centro Hospitalar São João, Faculdade de Medicina da Universidade de Porto, 4099-002 Porto, Portugal
- Instituto de Ciência e Inovação em Engenharia Mecânica e Engenharia Industrial, 4200-465 Porto, Portugal
| | - João Cavaleiro Rufo
- Portugal & Centro Hospitalar São João, Faculdade de Medicina da Universidade de Porto, 4099-002 Porto, Portugal
- EPIUnit—Instituto de Saúde Pública, Universidade do Porto, 4050-600 Porto, Portugal
| | - Edna Ribeiro
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1600-560 Lisbon, Portugal
| | - Elisabete Carolino
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1600-560 Lisbon, Portugal
| | - Carla Viegas
- H&TRC—Health & Technology Research Center, ESTeSL—Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, 1600-560 Lisbon, Portugal
- Centro de Investigação em Saúde Pública, Universidade NOVA de Lisboa, 1600-560 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), 1600-560 Lisbon, Portugal
| | - António Sousa Uva
- Escola Nacional de Saúde Pública, Universidade NOVA de Lisboa, 1600-560 Lisbon, Portugal
- Centro de Investigação em Saúde Pública, Universidade NOVA de Lisboa, 1600-560 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), 1600-560 Lisbon, Portugal
| | - Sandra Cabo Verde
- Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, 1600-560 Lisbon, Portugal
| |
Collapse
|
8
|
Azole-Resistant Aspergillus fumigatus Harboring the TR 34/L98H Mutation: First Report in Portugal in Environmental Samples. Microorganisms 2020; 9:microorganisms9010057. [PMID: 33379247 PMCID: PMC7823791 DOI: 10.3390/microorganisms9010057] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/06/2020] [Accepted: 12/23/2020] [Indexed: 02/07/2023] Open
Abstract
Introduction: The frequency in detection of azole-resistant Aspergillus fumigatus isolates has increased since 2010. In Portugal, the section Fumigati is one of the most frequent, and resistant strains to have been found in clinical and environmental contexts. Although several cryptic species within the Fumigati section show intrinsic resistance to azoles, one factor driving (acquired) resistance is selective pressure deriving from the extensive use of azoles. This is particularly problematic in occupational environments where high fungal loads are expected, and where there is an increased risk of human exposure and infection, with impact on treatment success and disease outcome. The mechanisms of resistance are diverse, but mainly associated with mutations in the cyp51A gene. Despite TR34/L98H being the most frequent mutation described, it has only been detected in clinical specimens in Portugal. Methods: We analyzed 99 A. fumigatus isolates from indoor environments (healthcare facilities, spas, one dairy and one waste sorting unit) collected from January 2018 to February 2019 in different regions of Portugal. Isolates were screened for resistance to itraconazole, voriconazole and posaconazole by culture, and resistance was confirmed by broth microdilution. Sequencing of the cyp51A gene and its promoter was performed to detect mutations associated with resistance. Results: Overall, 8.1% of isolates were able to grow in the presence of at least one azole, and 3% (isolated from the air in a dairy and from filtering respiratory protective devices in a waste sorting industry) were pan-azole-resistant, bearing the TR34/L98H mutation. Conclusion: For the first time in Portugal, we report environmental isolates bearing the TR34/L98H mutation, isolated from occupational environments. Environmental surveillance of the emergence of azole-resistant A. fumigatus sensu stricto strains is needed, to ensure proper and timely implementation of control policies that may have a positive impact on public and occupational health.
Collapse
|