1
|
Trujillo-González A, Thuo DN, Divi U, Sparks K, Wallenius T, Gleeson D. Detection of Khapra Beetle Environmental DNA Using Portable Technologies in Australian Biosecurity. FRONTIERS IN INSECT SCIENCE 2022; 2:795379. [PMID: 38468794 PMCID: PMC10926498 DOI: 10.3389/finsc.2022.795379] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 01/12/2022] [Indexed: 03/13/2024]
Abstract
Khapra beetle, Trogoderma granarium Everts, 1898, is a serious pest of stored grain products globally. Environmental DNA (eDNA)-based methods offer sensitive detection tools used to inform biosecurity officers on the presence of high-risk pests. This study tested laboratory and portable molecular technologies to detect khapra beetle environmental DNA extracted from dust samples collected during biosecurity responses (Tuggeranong and Fyshwick) to khapra beetle incursions in Australia. Airborne and floor dust samples were collected opportunistically using handheld vacuum cleaners and eDNA was extracted using either field or laboratory-based extraction methods and analyzed using laboratory benchtop real time PCR machines and portable machines with two TaqMan and one LAMP-based assay. We successfully collected, extracted, and amplified khapra beetle eDNA from dust samples by qPCR, but failed to amplify T. granarium eDNA using LAMP. The Laboratory qPCR machine showed significantly higher mean Ct values (p < 0.001) and significantly higher positive detections for both assays (p < 0.001) compared to the portable thermocycler. DNA yield was significantly higher in samples extracted using laboratory-based kits compared to field kits (p < 0.001) for both vacuumed and airborne samples (Mean DNA ± S.D. = 5.52 ± 4.45 and 4.77 ± 1.68 ng/μL, respectively), compared to field kits, (1.75 ± 1.17 and 1.36± 1.29 ng/μL for vacuumed and airborne samples, respectively). There were no significant differences in DNA yield between collection methods or differences in amplification associated to extraction or collection methods in either platform tested in this study. Portable technologies tested in this study (Franklin™ Real Time Thermocycler and Genie III) accurately amplified all tissue derived DNA during assay optimisation and field testing, highlighting the capacity of these technologies to complement biosecurity in confirming specimen ID. There was a high incidence of positive detections in field negative controls (Tuggeranong = 12.3 % and Fyshwick = 50 %), mostly attributed to the use of contaminated vacuum cleaners. We discuss suitable methods to minimize sample cross-contamination, the potential of portable molecular technologies as tools for biosecurity applications, and the suitability of eDNA-based molecular detection methods to complement global trade biosecurity for one of the most invasive and important grain pests worldwide.
Collapse
Affiliation(s)
- Alejandro Trujillo-González
- EcoDNA Group, Centre for Conservation Ecology and Genomics, University of Canberra, Canberra, ACT, Australia
| | - David N. Thuo
- EcoDNA Group, Centre for Conservation Ecology and Genomics, University of Canberra, Canberra, ACT, Australia
| | - Uday Divi
- Biosecurity Strategy and Reform Division, Department of Agriculture, Water, and the Environment, Canberra, ACT, Australia
| | - Kate Sparks
- Science and Surveillance Group, Biosecurity Plant Division, Department of Agriculture, Water and the Environment, Canberra, ACT, Australia
| | - Thomas Wallenius
- Science and Surveillance Group, Biosecurity Plant Division, Department of Agriculture, Water and the Environment, Canberra, ACT, Australia
| | - Dianne Gleeson
- EcoDNA Group, Centre for Conservation Ecology and Genomics, University of Canberra, Canberra, ACT, Australia
| |
Collapse
|
2
|
Advances in Directly Amplifying Nucleic Acids from Complex Samples. BIOSENSORS-BASEL 2019; 9:bios9040117. [PMID: 31574959 PMCID: PMC6955841 DOI: 10.3390/bios9040117] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 09/23/2019] [Accepted: 09/26/2019] [Indexed: 12/15/2022]
Abstract
Advances in nucleic acid amplification technologies have revolutionized diagnostics for systemic, inherited, and infectious diseases. Current assays and platforms, however, often require lengthy experimental procedures and multiple instruments to remove contaminants and inhibitors from clinically-relevant, complex samples. This requirement of sample preparation has been a bottleneck for using nucleic acid amplification tests (NAATs) at the point of care (POC), though advances in “lab-on-chip” platforms that integrate sample preparation and NAATs have made great strides in this space. Alternatively, direct NAATs—techniques that minimize or even bypass sample preparation—present promising strategies for developing POC diagnostic tools for analyzing real-world samples. In this review, we discuss the current status of direct NAATs. Specifically, we surveyed potential testing systems published from 1989 to 2017, and analyzed their performances in terms of robustness, sensitivity, clinical relevance, and suitability for POC diagnostics. We introduce bubble plots to facilitate our analysis, as bubble plots enable effective visualization of the performances of these direct NAATs. Through our review, we hope to initiate an in-depth examination of direct NAATs and their potential for realizing POC diagnostics, and ultimately transformative technologies that can further enhance healthcare.
Collapse
|
3
|
Simultaneous Detection of Different Zika Virus Lineages via Molecular Computation in a Point-of-Care Assay. Viruses 2018; 10:v10120714. [PMID: 30558136 PMCID: PMC6316447 DOI: 10.3390/v10120714] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2018] [Revised: 12/08/2018] [Accepted: 12/11/2018] [Indexed: 02/06/2023] Open
Abstract
We have developed a generalizable “smart molecular diagnostic” capable of accurate point-of-care (POC) detection of variable nucleic acid targets. Our isothermal assay relies on multiplex execution of four loop-mediated isothermal amplification reactions, with primers that are degenerate and redundant, thereby increasing the breadth of targets while reducing the probability of amplification failure. An easy-to-read visual answer is computed directly by a multi-input Boolean OR logic gate (gate output is true if either one or more gate inputs is true) signal transducer that uses degenerate strand exchange probes to assess any combination of amplicons. We demonstrate our methodology by using the same assay to detect divergent Asian and African lineages of the evolving Zika virus (ZIKV), while maintaining selectivity against non-target viruses. Direct analysis of biological specimens proved possible, with crudely macerated ZIKV-infected Aedes aegypti mosquitoes being identified with 100% specificity and sensitivity. The ease-of-use with minimal instrumentation, broad programmability, and built-in fail-safe reliability make our smart molecular diagnostic attractive for POC use.
Collapse
|
4
|
Williams MR, Stedtfeld RD, Engle C, Salach P, Fakher U, Stedtfeld T, Dreelin E, Stevenson RJ, Latimore J, Hashsham SA. Isothermal amplification of environmental DNA (eDNA) for direct field-based monitoring and laboratory confirmation of Dreissena sp. PLoS One 2017; 12:e0186462. [PMID: 29036210 PMCID: PMC5643059 DOI: 10.1371/journal.pone.0186462] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Accepted: 10/02/2017] [Indexed: 02/01/2023] Open
Abstract
Loop-mediated isothermal amplification (LAMP) of aquatic invasive species environmental DNA (AIS eDNA) was used for rapid, sensitive, and specific detection of Dreissena sp. relevant to the Great Lakes (USA) basin. The method was validated for two uses including i) direct amplification of eDNA using a hand filtration system and ii) confirmation of the results after DNA extraction using a conventional thermal cycler run at isothermal temperatures. Direct amplification eliminated the need for DNA extraction and purification and allowed detection of target invasive species in grab or concentrated surface water samples, containing both free DNA as well as larger cells and particulates, such as veligers, eggs, or seeds. The direct amplification method validation was conducted using Dreissena polymorpha and Dreissena bugensis and uses up to 1 L grab water samples for high target abundance (e.g., greater than 10 veligers (larval mussels) per L for Dreissena sp.) or 20 L samples concentrated through 35 μm nylon screens for low target abundance, at less than 10 veligers per liter water. Surface water concentrate samples were collected over a period of three years, mostly from inland lakes in Michigan with the help of a network of volunteers. Field samples collected from 318 surface water locations included i) filtered concentrate for direct amplification validation and ii) 1 L grab water sample for eDNA extraction and confirmation. Though the extraction-based protocol was more sensitive (resulting in more positive detections than direct amplification), direct amplification could be used for rapid screening, allowing for quicker action times. For samples collected between May and August, results of eDNA direct amplification were consistent with known presence/absence of selected invasive species. A cross-platform smartphone application was also developed to disseminate the analyzed results to volunteers. Field tests of the direct amplification protocol using a portable device (Gene-Z) showed the method could be used in the field to obtain results within one hr (from sample to result). Overall, the direct amplification has the potential to simplify the eDNA-based monitoring of multiple aquatic invasive species. Additional studies are warranted to establish quantitative correlation between eDNA copy number, veliger, biomass or organismal abundance in the field.
Collapse
Affiliation(s)
- Maggie R. Williams
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Robert D. Stedtfeld
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Cathrine Engle
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Paul Salach
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Umama Fakher
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Tiffany Stedtfeld
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
| | - Erin Dreelin
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, Michigan, United States of America
- Center for Water Sciences, Michigan State University, East Lansing, Michigan, United States of America
| | - R. Jan Stevenson
- Center for Water Sciences, Michigan State University, East Lansing, Michigan, United States of America
- Department of Integrative Biology, Michigan State University, East Lansing, Michigan, United States of America
| | - Jo Latimore
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, Michigan, United States of America
| | - Syed A. Hashsham
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, United States of America
- Center for Microbial Ecology, Michigan State University, East Lansing, Michigan, United States of America
- * E-mail:
| |
Collapse
|
5
|
Shi Y, Feng Y, Xu C, Xu Z, Cheng D, Lu Y. Loop-Mediated Isothermal Amplification Assays for the Rapid Identification of Duck-Derived Ingredients in Adulterated Meat. FOOD ANAL METHOD 2017. [DOI: 10.1007/s12161-016-0767-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
6
|
The detection of Atlantic cod (Gadus morhua) using loop mediated isothermal amplification in conjunction with a simplified DNA extraction process. Food Control 2016. [DOI: 10.1016/j.foodcont.2015.05.038] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Stedtfeld RD, Liu YC, Stedtfeld TM, Kostic T, Kronlein M, Srivannavit O, Khalife WT, Tiedje JM, Gulari E, Hughes M, Etchebarne B, Hashsham SA. Static self-directed sample dispensing into a series of reaction wells on a microfluidic card for parallel genetic detection of microbial pathogens. Biomed Microdevices 2015; 17:89. [PMID: 26260693 PMCID: PMC4531140 DOI: 10.1007/s10544-015-9994-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A microfluidic card is described for simultaneous and rapid genetic detection of multiple microbial pathogens. The hydrophobic surface of native acrylic and a novel microfluidic mechanism termed "airlock" were used to dispense sample into a series of 64 reaction wells without the use of valves, external pumping peripherals, multiple layers, or vacuum assistance. This airlock mechanism was tested with dilutions of whole human blood, saliva, and urine, along with mock samples of varying viscosities and surface tensions. Samples spiked with genomic DNA (gDNA) or crude lysates from clinical bacterial isolates were tested with loop mediated isothermal amplification assays (LAMP) designed to target virulence and antibiotic resistance genes. Reactions were monitored in real time using the Gene-Z, which is a portable smartphone-driven system. Samples loaded correctly into the microfluidic card in 99.3% of instances. Amplification results confirmed no carryover of pre-dispensed primer between wells during sample loading, and no observable diffusion between adjacent wells during the 60 to 90 min isothermal reaction. Sensitivity was comparable between LAMP reactions tested within the microfluidic card and in conventional vials. Tests demonstrate that the airlock card works with various sample types, manufacturing techniques, and can potentially be used in many point-of-care diagnostics applications.
Collapse
Affiliation(s)
- Robert D. Stedtfeld
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
| | - Yen-Cheng Liu
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
| | - Tiffany M. Stedtfeld
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
| | - Tanja Kostic
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
- />Bioresources Unit, AIT Austrian Institute of Technology GmbH, Konrad Lorenz Strasse 24, A-3430 Tulln, Austria
| | - Maggie Kronlein
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
| | - Onnop Srivannavit
- />Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109 USA
| | - Walid T. Khalife
- />Department of Microbiology, Sparrow Laboratories, Sparrow Health System, Lansing, MI 48912 USA
| | - James M. Tiedje
- />The Center for Microbial Ecology, Michigan State University, East Lansing, MI 48824 USA
- />Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, MI 48824 USA
| | - Erdogan Gulari
- />Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109 USA
| | - Mary Hughes
- />Department of Osteopathic Medical Specialties, Section of Emergency Medicine, College of Osteopathic Medicine, Michigan State University, East Lansing, MI 48824 USA
| | - Brett Etchebarne
- />Department of Osteopathic Medical Specialties, Section of Emergency Medicine, College of Osteopathic Medicine, Michigan State University, East Lansing, MI 48824 USA
| | - Syed A. Hashsham
- />Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824 USA
- />The Center for Microbial Ecology, Michigan State University, East Lansing, MI 48824 USA
| |
Collapse
|
8
|
Stedtfeld RD, Stedtfeld TM, Kronlein M, Seyrig G, Steffan RJ, Cupples AM, Hashsham SA. DNA extraction-free quantification of Dehalococcoides spp. in groundwater using a hand-held device. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:13855-63. [PMID: 25360694 DOI: 10.1021/es503472h] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Nucleic acid amplification of biomarkers is increasingly used to measure microbial activity and predict remedial performance in sites with trichloroethene (TCE) contamination. Field-based genetic quantification of microorganisms associated with bioremediation may help increase accuracy that is diminished through transport and processing of groundwater samples. Sterivex cartridges and a previously undescribed mechanism for eluting biomass was used to concentrate cells. DNA extraction-free loop mediated isothermal amplification (LAMP) was monitored in real-time with a point of use device (termed Gene-Z). A detection limit of 10(5) cells L(–1) was obtained, corresponding to sensitivity between 10 to 100 genomic copies per reaction for assays targeting the Dehalococcoides spp. specific 16S rRNA gene and vcrA gene, respectively. The quantity of Dehalococcoides spp. genomic copies measured from two TCE contaminated groundwater samples with conventional means of quantification including filtration, DNA extraction, purification, and qPCR was comparable to the field ready technique. Overall, this method of measuring Dehalococcoides spp. and vcrA genes in groundwater via direct amplification without intentional DNA extraction and purification is demonstrated, which may provide a more accurate mechanism of predicting remediation rates.
Collapse
Affiliation(s)
- Robert D Stedtfeld
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan 48824, United States
| | | | | | | | | | | | | |
Collapse
|
9
|
Moradi A, Almasi MA, Jafary H, Mercado-Blanco J. A novel and rapid loop-mediated isothermal amplification assay for the specific detection of Verticillium dahliae. J Appl Microbiol 2013; 116:942-54. [PMID: 24329885 DOI: 10.1111/jam.12407] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Revised: 11/21/2013] [Accepted: 11/22/2013] [Indexed: 11/29/2022]
Abstract
AIMS In this study, a loop-mediated isothermal amplification (LAMP) assay has been developed and evaluated for the rapid and sensitive detection of Verticillium dahliae Kleb., the causal agent of vascular wilts in many economically important crops. METHODS AND RESULTS LAMP primers were designed based on a previously described RAPD marker, and the LAMP assay was applied for direct detection of V. dahliae grown on medium and from soil samples without DNA purification steps (direct-LAMP). Thirty-two agricultural soil samples from various olive orchards were collected, and the presence of pathogen was detected by LAMP, direct-LAMP and nested-PCR methods. The LAMP methodology could successfully detect V. dahliae with high specificity, and cross-reaction was not observed with different pathogenic and nonpathogenic fungi and bacteria. The LAMP assay was capable of detecting a minimum of 500 and 50 fg of purified target DNA per reaction of V. dahliae ND and D pathotypes, respectively. In contrast, nested-PCR could only detect 5 pg reaction(-1) for both pathotypes. In artificially infested soil samples, the LAMP method detected 5 microsclerotia per gram of soil. Conversely, nested-PCR assay detected 50 microsclerotia g(-1) soil. The detection ratios of LAMP and direct-LAMP protocols were better (26 and 24 positive samples out of 32 agricultural soils analysed, respectively) than that obtained for nested-PCR method (22 positive results). Moreover, direct-LAMP yielded positive detection of V. dahliae in agricultural soil samples within 60-80 min. CONCLUSIONS The newly developed LAMP method was proved to be an effective, simple and rapid method to detect V. dahliae without the need for either expensive equipment or DNA purification. SIGNIFICANCE AND IMPACT OF STUDY This technique can be considered as an excellent standard alternative to plating and nested-PCR assays for the early, sensitive and low-cost detection of V. dahliae as well as other soilborne pathogens in the field.
Collapse
Affiliation(s)
- A Moradi
- Department of Biotechnology, Research Institute of Physiology and Biotechnology, University of Zanjan, Zanjan, Iran
| | | | | | | |
Collapse
|
10
|
Boyle DS, Lehman DA, Lillis L, Peterson D, Singhal M, Armes N, Parker M, Piepenburg O, Overbaugh J. Rapid detection of HIV-1 proviral DNA for early infant diagnosis using recombinase polymerase amplification. mBio 2013; 4:e00135-13. [PMID: 23549916 PMCID: PMC3622927 DOI: 10.1128/mbio.00135-13] [Citation(s) in RCA: 187] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Accepted: 02/22/2013] [Indexed: 12/12/2022] Open
Abstract
Early diagnosis and treatment of human immunodeficiency virus type 1 (HIV-1) infection in infants can greatly reduce mortality rates. However, current infant HIV-1 diagnostics cannot reliably be performed at the point of care, often delaying treatment and compromising its efficacy. Recombinase polymerase amplification (RPA) is a novel technology that is ideal for an HIV-1 diagnostic, as it amplifies target DNA in <20 min at a constant temperature, without the need for complex thermocycling equipment. Here we tested 63 HIV-1-specific primer and probe combinations and identified two RPA assays that target distinct regions of the HIV-1 genome (long terminal repeat [LTR] and pol) and can reliably detect 3 copies of proviral DNA by the use of fluorescence detection and lateral-flow strip detection. These pol and LTR primers amplified 98.6% and 93%, respectively, of the diverse HIV-1 variants tested. This is the first example of an isothermal assay that consistently detects all of the major HIV-1 global subtypes.
Collapse
Affiliation(s)
- David S Boyle
- Program for Appropriate Technology in Health, Seattle, WA, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|