1
|
Miescher I, Schaffner N, Rieber J, Bürgisser GM, Ongini E, Yang Y, Milionis A, Vogel V, Snedeker JG, Calcagni M, Buschmann J. Hyaluronic acid/PEO electrospun tube reduces tendon adhesion to levels comparable to native tendons - An in vitro and in vivo study. Int J Biol Macromol 2024; 273:133193. [PMID: 38885859 DOI: 10.1016/j.ijbiomac.2024.133193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 06/10/2024] [Accepted: 06/13/2024] [Indexed: 06/20/2024]
Abstract
A major problem after tendon injury is adhesion formation to the surrounding tissue leading to a limited range of motion. A viable strategy to reduce adhesion extent is the use of physical barriers that limit the contact between the tendon and the adjacent tissue. The purpose of this study was to fabricate an electrospun bilayered tube of hyaluronic acid/polyethylene oxide (HA/PEO) and biodegradable DegraPol® (DP) to improve the anti-adhesive effect of the implant in a rabbit Achilles tendon full laceration model compared to a pure DP tube. Additionally, the attachment of rabbit tenocytes on pure DP and HA/PEO containing scaffolds was tested and Scanning Electron Microscopy, Fourier-transform Infrared Spectroscopy, Differential Scanning Calorimetry, Water Contact Angle measurements, and testing of mechanical properties were used to characterize the scaffolds. In vivo assessment after three weeks showed that the implant containing a second HA/PEO layer significantly reduced adhesion extent reaching levels comparable to native tendons, compared with a pure DP implant that reduced adhesion formation only by 20 %. Tenocytes were able to attach to and migrate into every scaffold, but cell number was reduced over two weeks. Implants containing HA/PEO showed better mechanical properties than pure DP tubes and with the ability to entirely reduce adhesion extent makes this implant a promising candidate for clinical application in tendon repair.
Collapse
Affiliation(s)
- Iris Miescher
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| | - Nicola Schaffner
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| | - Julia Rieber
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| | - Gabriella Meier Bürgisser
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| | - Esteban Ongini
- University Clinic Balgrist, Orthopaedic Biomechanics, Forchstrasse 340, 8008 Zurich, Switzerland.
| | - Yao Yang
- Department of Health Sciences & Technology & Department of Materials, Schmelzbergstrasse 9, LFO, 8092 Zürich, Switzerland.
| | - Athanasios Milionis
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland.
| | - Viola Vogel
- Laboratory of Applied Mechanobiology, Institute of Translational Medicine, and Department of Health Sciences and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Jess G Snedeker
- University Clinic Balgrist, Orthopaedic Biomechanics, Forchstrasse 340, 8008 Zurich, Switzerland.
| | - Maurizio Calcagni
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| | - Johanna Buschmann
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland.
| |
Collapse
|
2
|
Wei S, Li Q, Wu H, Kong C, Xu F, Cai X. All-inside endoscopic semiautomatic running locked stitch technique shows favourable outcomes for acute Achilles tendon ruptures. Knee Surg Sports Traumatol Arthrosc 2024; 32:1615-1621. [PMID: 38578228 DOI: 10.1002/ksa.12177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 03/12/2024] [Accepted: 03/17/2024] [Indexed: 04/06/2024]
Abstract
PURPOSE The safety and reliability of endoscopic Achilles tendon rupture repair are still concerning aspects. This study's aim is to evaluate an all-inside endoscopic semiautomatic running locked stitch (Endo-SARLS) technique. METHODS Forty cases with acute Achilles tendon rupture were treated with the all-inside Endo-SARLS technique between 2020 and 2021. Under endoscopic control, the proximal tendon stumps were stitched with the running locked method using a semiautomatic flexible suture passer. The threads of the high-strength suture were grasped through the paratenon subspace and then fixed into calcaneal insertion with a knotless anchor. Magnetic resonance imaging (MRI), surgical time and complications were assessed. Achilles Tendon Total Rupture Score (ATRS), Achilles Tendon Resting Angle (ATRA) and Heel Rise Height Scale (HRHS) were utilised to evaluate final outcomes. RESULTS The average follow-up time was 25.4 ± 0.4 (range: 24-32) months. Appropriate tendon regeneration was observed on MRI after 12 months. At the final follow-up, the median value of ATRS score was 95 (interquartile range: 94, 98). Furthermore, there is no significant difference between the injured and contralateral side in the average ATRA (18.2 ± 1.8 vs. 18.3 ± 1.9°, ns) and median value of HRHS [14.5 (13.3, 15.5) vs. 14.8 (13.5, 15.6) cm, ns]. No infection and nerve injuries were encountered. Thirty-nine patients reported that they resumed casual sports activity after 6 months. One patient had a slight anchor cut-out, due to an addition injury, which was removed after 5 months. CONCLUSIONS An all-inside Endo-SARLS technique showed promising clinical results for acute Achilles tendon ruptures. This procedure reduces the risk of sural nerve injuries while establishing a reliable connection between the tendon stumps. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Shijun Wei
- Department of Orthopaedics, General Hospital of Central Theater Command, Wuhan, China
- The First Clinical Medical School, Southern Medical University, Guangzhou, China
| | - Qing Li
- Department of Orthopaedics, General Hospital of Central Theater Command, Wuhan, China
| | - Helin Wu
- Department of Orthopaedics, General Hospital of Central Theater Command, Wuhan, China
- The First Clinical Medical School, Southern Medical University, Guangzhou, China
| | - Changwang Kong
- Department of Orthopaedics, General Hospital of Central Theater Command, Wuhan, China
| | - Feng Xu
- Department of Orthopaedics, General Hospital of Central Theater Command, Wuhan, China
- The First Clinical Medical School, Southern Medical University, Guangzhou, China
| | - Xianhua Cai
- Department of Orthopaedics, South China Hospital of Shenzhen University, Shenzhen, China
| |
Collapse
|
3
|
Rodriguez-Materon S, Trynz S, Ahmed MA, SanGiovanni TP, Chapman C, Hodgkins CW. First 30 Days Wound-Related Complications in Young Smokers Following Primary Achilles Repair. J Foot Ankle Surg 2024; 63:9-12. [PMID: 37855794 DOI: 10.1053/j.jfas.2022.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 08/23/2022] [Accepted: 08/28/2022] [Indexed: 10/20/2023]
Abstract
The Achilles tendon is frequently injured in the young to middle aged population. Previous studies have shown that there is an increased risk of delay in postsurgical wound healing amongst tobacco smoking patients with Achilles tendon injury. This study utilized the American College of Surgeons National Surgical Quality Improvement Project (ACS-NSQIP) database. We included patients between the ages of 18 and 35 years who underwent primary Achilles tendon repair between years 2011 and 2020. The procedure type (with or without graft, CPT 27650 and 27652), patient demographics, and comorbidities were included. Primary outcomes of interest were 30-day readmission, minor complications, outcomes related to wound healing (wound disruption, superficial surgical site infection, deep incisional surgical site infection, organ-space site infections) and reoperations within 30 days of index surgery. A total of 1944 patients met the inclusion criteria for this study. One thousand six hundred and fifty-nine patients were nonsmokers, while 285 were smokers. Logistic regression showed no differences between smokers and nonsmokers (reference group) for 30-day readmission, reoperation, and minor complications. However, Black non-Hispanic patients were found to be 0.3 times (95% confidence interval: 0.1, 0.98) as likely to develop minor complications as compared to the White non-Hispanic patients. Wound-related complications after Achilles tendon repair remain low in younger (18-35 years) patients. When comparing clinical outcomes between nonsmokers and smokers, we found no statistically significant difference in this retrospective study.
Collapse
Affiliation(s)
| | - Samantha Trynz
- Herbert Wertheim College of Medicine, Florida International University, Miami, FL
| | - Md Ashfaq Ahmed
- Center for Advanced Analytics, Baptist Health South Florida, Coral Gables, FL
| | - Thomas P SanGiovanni
- Orthopedic Surgeon, Foot and Ankle Specialist, Baptist Health Orthopaedic Care, Baptist Health South Florida, Coral Gables, FL
| | - Cary Chapman
- Orthopedic Surgeon, Foot and Ankle Specialist, Baptist Health Orthopaedic Care, Baptist Health South Florida, Coral Gables, FL
| | - Christopher W Hodgkins
- Orthopedic Surgeon, Foot and Ankle Specialist, Baptist Health Orthopaedic Care, Baptist Health South Florida, Coral Gables, FL
| |
Collapse
|
4
|
Rieber J, Meier-Bürgisser G, Miescher I, Weber FE, Wolint P, Yao Y, Ongini E, Milionis A, Snedeker JG, Calcagni M, Buschmann J. Bioactive and Elastic Emulsion Electrospun DegraPol Tubes Delivering IGF-1 for Tendon Rupture Repair. Int J Mol Sci 2023; 24:10272. [PMID: 37373418 DOI: 10.3390/ijms241210272] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/14/2023] [Accepted: 06/14/2023] [Indexed: 06/29/2023] Open
Abstract
Tendon injuries can result in two major drawbacks. Adhesions to the surrounding tissue may limit the range of motion, while fibrovascular scar formation can lead to poor biomechanical outcomes. Prosthetic devices may help to mitigate those problems. Emulsion electrospinning was used to develop a novel three-layer tube based on the polymer DegraPol (DP), with incorporated insulin-like growth factor-1 (IGF-1) in the middle layer. Scanning electron microscopy was utilized to assess the fiber diameter in IGF-1 containing pure DP meshes. Further characterization was performed with Fourier Transformed Infrared Spectroscopy, Differential Scanning Calorimetry, and water contact angle, as well as through the assessment of mechanical properties and release kinetics from ELISA, and the bioactivity of IGF-1 by qPCR of collagen I, ki67, and tenomodulin in rabbit Achilles tenocytes. The IGF-1-containing tubes exhibited a sustained release of the growth factor up to 4 days and showed bioactivity by significantly upregulated ki67 and tenomodulin gene expression. Moreover, they proved to be mechanically superior to pure DP tubes (significantly higher fracture strain, failure stress, and elastic modulus). The novel three-layer tubes intended to be applied over conventionally sutured tendons after a rupture may help accelerate the healing process. The release of IGF-1 stimulates proliferation and matrix synthesis of cells at the repair site. In addition, adhesion formation to surrounding tissue can be reduced due to the physical barrier.
Collapse
Affiliation(s)
- Julia Rieber
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Gabriella Meier-Bürgisser
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Iris Miescher
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Franz E Weber
- Oral Biotechnology & Bioengineering, Center for Dental Medicine, Cranio-Maxillofacial and Oral Surgery, University of Zurich, 8032 Zurich, Switzerland
| | - Petra Wolint
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Yang Yao
- Department of Health Sciences & Technology & Department of Materials, Schmelzbergstrasse 9, LFO, 8092 Zurich, Switzerland
| | - Esteban Ongini
- Orthopaedic Biomechanics, University Clinic Balgrist, Forchstrasse 340, 8008 Zurich, Switzerland
| | - Athanasios Milionis
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland
| | - Jess G Snedeker
- Orthopaedic Biomechanics, University Clinic Balgrist, Forchstrasse 340, 8008 Zurich, Switzerland
| | - Maurizio Calcagni
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Johanna Buschmann
- Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| |
Collapse
|
5
|
Diniz P, Ferreira AS, Figueiredo L, Batista JP, Abdelatif N, Pereira H, Kerkhoffs GMMJ, Finkelstein SN, Ferreira FC. Early analysis shows that endoscopic flexor hallucis longus transfer has a promising cost-effectiveness profile in the treatment of acute Achilles tendon ruptures. Knee Surg Sports Traumatol Arthrosc 2022; 31:2001-2014. [PMID: 36149468 DOI: 10.1007/s00167-022-07146-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 08/30/2022] [Indexed: 11/28/2022]
Abstract
PURPOSE Current options for treating an Achilles tendon rupture (ATR) include conservative and surgical approaches. Endoscopic flexor hallucis longus (FHL) transfer has been recently proposed to treat acute ruptures, but its cost-effectiveness potential remains to be evaluated. Therefore, the objective of this study was to perform an early cost-effectiveness analysis of endoscopic FHL transfer for acute ATRs, comparing the costs and benefits of current treatments from a societal perspective. METHODS A conceptual model was created, with a decision tree, to outline the main health events during the treatment of an acute ATR. The model was parameterized using secondary data. A systematic review of the literature was conducted to gather information on the outcomes of current treatments. Data related to outcomes of endoscopic FHL transfers in acute Achilles ruptures was obtained from a single prospective study. Analysis was limited to the two first years. The incremental cost-effectiveness ratio was the main outcome used to determine the preferred strategy. A willingness-to-pay threshold of $100,000 per quality-adjusted life-year was used. Sensitivity analyses were performed to determine whether changes in input parameters would cause significant deviation from the reference case results. Specifically, a probability sensitivity analysis was conducted using Monte Carlo simulations, and a one-way sensitivity analysis was conducted by sequentially varying each model parameter within a given range. RESULTS For the reference case, incremental cost-effectiveness ratios exceeded the willingness-to-pay threshold for all the surgical approaches. Overall, primary treatment was the main cost driver. Conservative treatment showed the highest direct costs related to the treatment of complications. In the probabilistic sensitivity analysis, at a willingness-to-pay threshold of $100,000, open surgery was cost-effective in 50.9%, minimally invasive surgery in 55.8%, and endoscopic FHL transfer in 72% of the iterations. The model was most sensitive to parameters related to treatment utilities, followed by the costs of primary treatments. CONCLUSION Surgical treatments have a moderate likelihood of being cost-effective at a willingness-to-pay threshold of $100,000, with endoscopic FHL transfer showing the highest likelihood. Following injury, interventions to improve health-related quality of life may be better suited for improved cost-effectiveness. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Pedro Diniz
- Department of Orthopaedic Surgery, Hospital de Sant'Ana, Rua de Benguela, 501, 2775-028, Parede, Lisbon, Portugal. .,Department of Bioengineering and iBB, Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal. .,Associate Laboratory i4HB, Institute for Health and Bioeconomy, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal. .,Fisiogaspar, Lisbon, Portugal.
| | - André Soares Ferreira
- Department of Orthopaedic Surgery, Hospital de Sant'Ana, Rua de Benguela, 501, 2775-028, Parede, Lisbon, Portugal
| | - Lígia Figueiredo
- Clinical Department Club Atletico Boca Juniors, CAJB Centro Artroscopico, Buenos Aires, Argentina
| | - Jorge Pablo Batista
- Head of Orthopedic Department, Dr Nasef OrthoClinic, Private Practice, Cairo, Egypt
| | - Nasef Abdelatif
- Orthopaedic Department, Centro Hospitalar Póvoa de Varzim, Vila Do Conde, Portugal
| | - Hélder Pereira
- Ripoll y De Prado Sports Clinic: FIFA Medical Centre of Excellence, Murcia/Madrid, Spain.,PT Government Associate Laboratory, University of Minho ICVS/3B's, Braga/Guimarães, Portugal.,Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Academic Center for Evidence Based Sports Medicine (ACES), Amsterdam University Medical Centers, Amsterdam Collaboration for Health and Safety in Sports (ACHSS), Amsterdam, The Netherlands
| | - Gino M M J Kerkhoffs
- Institute for Data, Systems and Society, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Stan N Finkelstein
- Division of Clinical Informatics, Beth Israel Deaconess Medical Center, Boston, MA, USA.,Bioceramed - Cerâmicos para Aplicações Médicas S.A., Loures, Portugal
| | - Frederico Castelo Ferreira
- Department of Bioengineering and iBB, Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.,Associate Laboratory i4HB, Institute for Health and Bioeconomy, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| |
Collapse
|