1
|
Kamble BB, Sharma KK, Sonawane KD, Tayade SN, Grammatikos S, Reddy YVM, Reddy SL, Shin JH, Park JP. Graphitic carbon nitride-based electrochemical sensors: A comprehensive review of their synthesis, characterization, and applications. Adv Colloid Interface Sci 2024; 333:103284. [PMID: 39226798 DOI: 10.1016/j.cis.2024.103284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 08/02/2024] [Accepted: 08/24/2024] [Indexed: 09/05/2024]
Abstract
Graphitic carbon nitride (g-C3N4) has garnered much attention as a promising 2D material in the realm of electrochemical sensors. It contains a polymeric matrix that can serve as an economical and non-toxic electrode material for the detection of a diverse range of analytes. However, its performance is impeded by a relatively limited active surface area and inherent instability. Although electrochemistry involving metal-doped g-C3N4 nanomaterials is rapidly progressing, it remains relatively unexplored. The metal doping of g-C3N4 augments the electrochemically active surface area of the resulting electrode, which has the potential to significantly enhance electrode kinetics and bolster catalytic activity. Consequentially, the main objective of this review is to provide insight into the intricacies of synthesizing and characterizing metal-doped g-C3N4. Furthermore, we comprehensively delve into the fundamental attributes of electrochemical sensors based on metal-doped g-C3N4, with a specific focus on healthcare and environmental applications. These applications encompass a meticulous exploration of detecting biomolecules, drug molecules, and organic pollutants.
Collapse
Affiliation(s)
- Bhagyashri B Kamble
- Department of Chemistry, Shivaji University, Kolhapur 416004, Maharashtra, India.
| | - Kiran Kumar Sharma
- School of Nanoscience and Biotechnology, Shivaji University, Kolhapur, Maharashtra 416004, India
| | - Kailas D Sonawane
- Department of Microbiology, Shivaji University, Kolhapur, Maharashtra 416004, India
| | - Shivaji N Tayade
- Department of Chemistry, Shivaji University, Kolhapur 416004, Maharashtra, India
| | - Sotirios Grammatikos
- ASEMlab - Laboratory of Advanced and Sustainable Engineering Materials, Department of Manufacturing and Civil Engineering, Norwegian University of Science and Technology (NTNU), Gjøvik, Norway
| | - Y Veera Manohara Reddy
- Department of Manufacturing and Civil Engineering, Norwegian University of Science and Technology (NTNU), Gjøvik, Norway; Department of Chemistry, Sri Venkateswara College, University of Delhi, New Delhi 110026, India.
| | - S Lokeswara Reddy
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi 630003, TN, India
| | - Jae Hwan Shin
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group, BK21 Four, Chung-Ang University, 4726 Seodongdaero, Anseong 17546, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group, BK21 Four, Chung-Ang University, 4726 Seodongdaero, Anseong 17546, Republic of Korea.
| |
Collapse
|
2
|
Gheorghe DC, Stefan-van Staden RI, van Staden JKF. Mini-Review: Electrochemical Sensors Used for the Determination of Water- and Fat-Soluble Vitamins: B, D, K. Crit Rev Anal Chem 2024; 54:1-10. [PMID: 35225092 DOI: 10.1080/10408347.2022.2045557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Vitamins are one of the most essential organic compounds that are necessary for the human body, in order to develop and grow in a healthy way. The aim of this mini-review is to bring together a series of electrochemical sensors (voltametric and amperometric) developed for the determination of vitamins from the families of B, D and K in biological, pharmaceutical or food-related samples. For this mini-review, 16 articles published between 2016 and 2021 were taken into consideration.
Collapse
Affiliation(s)
- Damaris-Cristina Gheorghe
- National Institute of Research for Electrochemistry and Condensed Matter, Timisoara - Laboratory of Electrochemistry and PATLAB, Bucharest, Romania
- Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, Bucharest, Romania
| | - Raluca-Ioana Stefan-van Staden
- National Institute of Research for Electrochemistry and Condensed Matter, Timisoara - Laboratory of Electrochemistry and PATLAB, Bucharest, Romania
- Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, Bucharest, Romania
| | - Jacobus Koos Frederick van Staden
- National Institute of Research for Electrochemistry and Condensed Matter, Timisoara - Laboratory of Electrochemistry and PATLAB, Bucharest, Romania
| |
Collapse
|
3
|
Dourandish Z, Sheikhshoaie I, Maghsoudi S. Molybdenum Disulfide/Nickel-Metal Organic Framework Hybrid Nanosheets Based Disposable Electrochemical Sensor for Determination of 4-Aminophenol in Presence of Acetaminophen. BIOSENSORS 2023; 13:bios13050524. [PMID: 37232885 DOI: 10.3390/bios13050524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
The toxicity of commonly used drugs, such as acetaminophen (ACAP) and its degradation-derived metabolite of 4-aminophenol (4-AP), underscores the need to achieve an effective approach in their simultaneous electrochemical determination. Hence, the present study attempts to introduce an ultra-sensitive disposable electrochemical 4-AP and ACAP sensor based on surface modification of a screen-printed graphite electrode (SPGE) with a combination of MoS2 nanosheets and a nickel-based metal organic framework (MoS2/Ni-MOF/SPGE sensor). A simple hydrothermal protocol was implemented to fabricate MoS2/Ni-MOF hybrid nanosheets, which was subsequently tested for properties using valid techniques including X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDX), Fourier transformed infrared spectroscopy (FTIR), and N2 adsorption-desorption isotherm. The 4-AP detection behavior on MoS2/Ni-MOF/SPGE sensor was followed by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV). Our experimental findings on the generated sensor confirmed a broad linear dynamic range (LDR) for 4-AP from 0.1 to 600 μM with a high sensitivity of 0.0666 μA/μM and a low limit of detection (LOD) of 0.04 μM. In addition, an analysis of real specimens such as tap water sample as well as a commercial sample (acetaminophen tablets) illuminated the successful applicability of as-developed sensor in determining ACAP and 4-AP, with an impressive recovery rate.
Collapse
Affiliation(s)
- Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| | - Shahab Maghsoudi
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| |
Collapse
|
4
|
He JY, Li Q, Xu HX, Zheng QY, Zhang QH, Zhou LD, Wang CZ, Yuan CS. Recognition and analysis of biomarkers in tumor microenvironments based on promising molecular imprinting strategies with high selectivity. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
|
5
|
Tripathi A, Bonilla-Cruz J. Review on Healthcare Biosensing Nanomaterials. ACS APPLIED NANO MATERIALS 2023; 6:5042-5074. [DOI: 10.1021/acsanm.3c00941] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Affiliation(s)
- Alok Tripathi
- Department of Chemical and Biochemical Engineering, School of Engineering, Indrashil University, Rajpur 382715, Gujarat India
| | - José Bonilla-Cruz
- Advanced Functional Materials and Nanotechnology Group, Centro de Investigación en Materiales Avanzados S. C. (CIMAV-Subsede Monterrey), Avenida Alianza Norte Autopista Monterrey-Aeropuerto Km 10, PIIT, Apodaca, Nuevo León, México C.P. 66628
| |
Collapse
|
6
|
Zaimbashi R, Tajik S, Beitollahi H, Torkzadeh-Mahani M. Fabrication of a Novel and Ultrasensitive Label-Free Electrochemical Aptasensor Based on Gold Nanostructure for Detection of Homocysteine. BIOSENSORS 2023; 13:bios13020244. [PMID: 36832010 PMCID: PMC9953955 DOI: 10.3390/bios13020244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/18/2023] [Accepted: 02/01/2023] [Indexed: 06/12/2023]
Abstract
The current attempt was made to detect the amino acid homocysteine (HMC) using an electrochemical aptasensor. A high-specificity HMC aptamer was used to fabricate an Au nanostructured/carbon paste electrode (Au-NS/CPE). HMC at high blood concentration (hyperhomocysteinemia) can be associated with endothelial cell damage leading to blood vessel inflammation, thereby possibly resulting in atherogenesis leading to ischemic damage. Our proposed protocol was to selectively immobilize the aptamer on the gate electrode with a high affinity to the HMC. The absence of a clear alteration in the current due to common interferants (methionine (Met) and cysteine (Cys)) indicated the high specificity of the sensor. The aptasensor was successful in sensing HMC ranging between 0.1 and 30 μM, with a narrow limit of detection (LOD) as low as 0.03 μM.
Collapse
Affiliation(s)
- Reza Zaimbashi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631818356, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631818356, Iran
| | - Masoud Torkzadeh-Mahani
- Biotechnology Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631818356, Iran
| |
Collapse
|
7
|
Graphene Oxide-PAMAM Nanocomposite and Ionic Liquid Modified Carbon Paste Electrode: An Efficient Electrochemical Sensor for Simultaneous Determination of Catechol and Resorcinol. Diagnostics (Basel) 2023; 13:diagnostics13040632. [PMID: 36832120 PMCID: PMC9954798 DOI: 10.3390/diagnostics13040632] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/03/2023] [Accepted: 02/05/2023] [Indexed: 02/11/2023] Open
Abstract
In this paper, a simple strategy was proposed for the analysis of catechol by a carbon paste electrode (CPE) modified with graphene oxide-third generation of poly(amidoamine) dendrimer (GO/G3-PAMAM) nanocomposite and ionic liquid (IL). The synthesis of GO-PAMAM nanocomposite was confirmed using X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), field emission scanning electron microscopy (FE-SEM), and Fourier transform infrared spectroscopy (FT-IR) techniques. The prepared modified electrode (GO-PAMAM/ILCPE) exhibited good performance to detect catechol with a notable decrease in overpotential and increase in current compared with an unmodified CPE. Under optimum experimental conditions, GO-PAMAM/ILCPE electrochemical sensors indicated a lower limit of detection (LOD) of 0.034 μM and a linear response in the concentration range of 0.1 to 200.0 µM for the quantitative measurement of catechol in aqueous solutions. In addition, GO-PAMAM/ILCPE sensor exhibited an ability to simultaneously determine catechol and resorcinol. It can be found that catechol and resorcinol could be completely separated on the GO-PAMAM/ILCPE with the differential pulse voltammetry (DPV) technique. Finally, a GO-PAMAM/ILCPE sensor was utilized to detect catechol and resorcinol in water samples with recoveries of 96.2% to 103.3% and relative standard deviations (RSDs) of less than 1.7%.
Collapse
|
8
|
Tajik S, Sharifi F, Aflatoonian B, Di Bartolomeo A. A New Electrochemical Sensor for the Detection of Ketoconazole Using Carbon Paste Electrode Modified with Sheaf-like Ce-BTC MOF Nanostructure and Ionic Liquid. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:523. [PMID: 36770482 PMCID: PMC9920814 DOI: 10.3390/nano13030523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/21/2023] [Accepted: 01/22/2023] [Indexed: 06/18/2023]
Abstract
An ultrasensitive and selective voltammetric sensor with an ultratrace-level detection limit is introduced for ketoconazole (KTC) determination in real samples using a modified carbon paste electrode with a sheaf-like Ce-BTC MOF nanostructure and ionic liquid. The as-synthesized nanostructure was characterized by several techniques, including energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), and field emission scanning electron microscopy (FE-SEM). The electrocatalytic performance of the developed electrode was observed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and chronoamperometry. The limit of detection (LOD) of the developed sensor for KTC is 0.04 μM, and the response was found to be in the dynamic concentration range of 0.1-110.0 μM in a phosphate buffer solution. The proposed electrode exhibits acceptable electrocatalytic activity for KTC oxidation with a high sensitivity of 0.1342 μA·μM-1. The ability of the fabricated sensor to monitor KTC in real aqueous samples is demonstrated using standard addition data.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman P.O. Box 76169-13555, Iran
| | - Fatemeh Sharifi
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman P.O. Box 76169-13555, Iran
| | - Behnaz Aflatoonian
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman P.O. Box 76169-13555, Iran
| | - Antonio Di Bartolomeo
- Department of Physics “E.R. Caianaiello”, University of Salerno, Fisciano, 84084 Salerno, Italy
| |
Collapse
|
9
|
Development of Stripping Voltammetry using Glassy Carbon Electrode Modified with Electrochemical Reduced Graphene Oxide for the Determination of Amaranth in Soft Drink and Candy Samples. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
10
|
Karami-Kolmoti P, Beitollahi H, Modiri S. Voltammetric detection of catechol in real samples using MnO2 nanorods-graphene oxide nanocomposite modified electrode. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2022. [DOI: 10.1007/s11694-022-01692-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
11
|
A review on rapid detection of modified quartz crystal microbalance sensors for food: Contamination, flavour and adulteration. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Beitollahi H, Garkani Nejad F, Dourandish Z, Tajik S. A novel voltammetric amaranth sensor based on screen printed electrode modified with polypyrrole nanotubes. ENVIRONMENTAL RESEARCH 2022; 214:113725. [PMID: 35732202 DOI: 10.1016/j.envres.2022.113725] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 05/01/2022] [Accepted: 06/15/2022] [Indexed: 05/26/2023]
Abstract
Azo dyes are the most used type of dye in the textile industry. Some of these dyes have the potential to be extremely toxic to both human health and the environment. The purpose of this study was to develope an electrochemical sensor for detection of amaranth. The electrochemical sensor based on the modification of a screen-printed electrode via polypyrrole nanotubes (PPy NTs/SPE) for detection of amaranth was developed. The preparation of PPy NTs was performed through the pyrrole monomer oxidation with iron (III) chloride in exposure to methyl orange as structure-guiding agent. Findings exhibited an excellent electrocatalytic activity of as-fabricated sensor for amaranth detection. Our sensor under the optimized circumstances also had a broad linear dynamic range (between 0.03 μM and 290.0 μM) and a narrow limit of detection (0.01 μM) towards the amaranth detection. Moreover, the proposed sensor could practically and successfully determine the amaranth content present in the real food specimens, with acceptable recovery rates.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran
| |
Collapse
|
13
|
Beitollahi H, Tajik S, Dourandish Z, Garkani Nejad F. Simple Preparation and Characterization of Hierarchical Flower-like NiCo 2O 4 Nanoplates: Applications for Sunset Yellow Electrochemical Analysis. BIOSENSORS 2022; 12:bios12110912. [PMID: 36354421 PMCID: PMC9688067 DOI: 10.3390/bios12110912] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/07/2022] [Accepted: 10/14/2022] [Indexed: 06/12/2023]
Abstract
The current work was performed to construct a novel electrochemical sensing system for determination of sunset yellow via the modification of screen-printed graphite electrode modified with hierarchical flower-like NiCo2O4 nanoplates (NiCo2O4/SPGE). The prepared material (hierarchical flower-like NiCo2O4 nanoplates) was analyzed by diverse microscopic and spectroscopic approaches for the crystallinity, composition, and morphology. Chronoamperometry, differential pulse voltammetry, linear sweep voltammetry, and cyclic voltammetry were used for determination of the electrochemical behavior of sunset yellow. The as-fabricated sensor had appreciable electro-catalytic performance and current sensitivity in detecting the sunset yellow. There were some advantages for NiCo2O4/SPGE under the optimized circumstances of sunset yellow determination, including a broad dynamic linear between 0.02 and 145.0 µM, high sensitivity of 0.67 μA/(μM.cm2), and a narrow limit of detection of 0.008 μM. The practical applicability of the proposed sensor was verified by determining the sunset yellow in real matrices, with satisfactory recoveries.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman P.O. Box 76169-13555, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| |
Collapse
|
14
|
Beitollahi H, Dourandish Z, Tajik S, Sharifi F, Jahani PM. Electrochemical Sensor Based on Ni-Co Layered Double Hydroxide Hollow Nanostructures for Ultrasensitive Detection of Sumatriptan and Naproxen. BIOSENSORS 2022; 12:bios12100872. [PMID: 36291009 PMCID: PMC9599541 DOI: 10.3390/bios12100872] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/02/2022] [Accepted: 10/06/2022] [Indexed: 06/12/2023]
Abstract
In this work, Ni-Co layered double hydroxide (Ni-Co LDH) hollow nanostructures were synthesized and characterized by X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM), and Fourier-transform infrared spectroscopy (FT-IR) techniques. A screen-printed electrode (SPE) surface was modified with as-fabricated Ni-Co LDHs to achieve a new sensing platform for determination of sumatriptan. The electrochemical behavior of the Ni-Co LDH-modified SPE (Ni-CO LDH/SPE) for sumatriptan determination was investigated using voltammetric methods. Compared with bare SPE, the presence of Ni-Co LDH was effective in the enhancement of electron transport rate between the electrode and analyte, as well as in the significant reduction of the overpotential of sumatriptan oxidation. Differential pulse voltammetry (DPV) was applied to perform a quantitative analysis of sumatriptan. The linearity range was found to be between 0.01 and 435.0 μM. The limits of detection (LOD) and sensitivity were 0.002 ± 0.0001 μM and 0.1017 ± 0.0001 μA/μM, respectively. In addition, the performance of the Ni-CO LDH/SPE for the determination of sumatriptan in the presence of naproxen was studied. Simultaneous analysis of sumatriptan with naproxen showed well-separated peaks leading to a quick and selective analysis of sumatriptan. Furthermore, the practical applicability of the prepared Ni-CO LDH/SPE sensor was examined in pharmaceutical and biological samples with satisfactory recovery results.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | - Fatemeh Sharifi
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | | |
Collapse
|
15
|
Poursoltani Zarandi M, Beitollahi H. Design of electrochemical sensor based on N-doped reduced graphene oxide/copper oxide nanocomposite and ionic liquid for the simultaneous determination of 4-aminophenol and acetaminophen. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
16
|
Jahani PM, Nejad FG, Dourandish Z, Zarandi MP, Safizadeh MM, Tajik S, Beitollahi H. A modified carbon paste electrode with N-rGO/CuO nanocomposite and ionic liquid for the efficient and cheap voltammetric sensing of hydroquinone in water specimens. CHEMOSPHERE 2022; 302:134712. [PMID: 35487364 DOI: 10.1016/j.chemosphere.2022.134712] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/10/2022] [Accepted: 04/21/2022] [Indexed: 06/14/2023]
Abstract
This paper reports a voltammetric sensor based on copper oxide nanoparticles on nitrogen-doped reduced graphene oxide nanocomposite (N-rGO/CuO)-ionic liquid modified carbon paste electrode (N-rGO/CuO-ILCPE) for determining the hydroquinone (HQ). The N-rGO/CuO was prepared by a facile protocol, followed by characterization via fourier transform-infrared (FT-IR) patterns, field emission-scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), and X-ray diffraction (XRD) analysis. The electrochemical behaviour was linearly symmetrical to various hydroquinone levels (1.0-600.0 μM) with a narrow limit of detection (LOD = 0.25 μM). The diffusion coefficient was also estimated to be 4.1 × 10-6 cm2/s. The N-rGO/CuO-ILCPE was impressively applicable in determination of hydroquinone in the real specimens.
Collapse
Affiliation(s)
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Mostafa Poursoltani Zarandi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | | | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran.
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| |
Collapse
|
17
|
A Voltammetric Sensor for the Determination of Hydroxylamine Using a Polypyrrole Nanotubes-Modified Electrode. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157485] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In this work, we develop an electrochemical sensor using a polypyrrole nanotubes-modified graphite screen-printed electrode (PPy NTs/GSPE) for sensing hydroxylamine. The PPy NTs/GSPE-supported sensor has an appreciable electrocatalytic performance and great stability for hydroxylamine oxidation. Compared to a bare graphite screen-printed electrode, we demonstrate that using the PPy NTs/GSPE leads to a significant reduction in the oxidation potential of hydroxylamine. The standard curve shows a linear relationship ranging from 0.005 to 290.0 μM (R2 = 0.9998), with a high sensitivity (0.1349 μA/μM) and a narrow limit of detection (LOD) of 0.001 μM. In addition, the PPy NTs/GSPE has satisfactory outcomes for hydroxylamine detection in real specimens.
Collapse
|
18
|
Jahani PM, Beitollahi H, Nejad FG, Dourandish Z, Di Bartolomeo A. Screen-printed graphite electrode modified with Co 3O 4nanoparticles and 2D graphitic carbon nitride as an effective electrochemical sensor for 4-aminophenol detection. NANOTECHNOLOGY 2022; 33:395702. [PMID: 35688102 DOI: 10.1088/1361-6528/ac779f] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/10/2022] [Indexed: 06/15/2023]
Abstract
We fabricated a new electrochemical 4-aminophenol sensor based on a nanocomposite of Co3O4nanoparticles and graphite carbon nitride (Co3O4@g-C3N4), used for the modification of a screen-printed electrode (Co3O4@g-C3N4/SPE). The synthesized nanocomposite was characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, x-ray diffraction and Fourier transform-infrared (FT-IR) techniques. The electro-oxidation of 4-aminophenol in phosphate buffer solution (pH = 7.0) was investigated via cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The peak current of oxidation in the optimized conditions had a linear relationship with various 4-aminophenol contents (0.05-780.0μM) with a correlation coefficient of 0.9996 and the limit of detection (S/N = 3) of 1.5 × 10-8M. The developed method was successful to determine 4-aminophenol in real specimens, with acceptable outcomes.
Collapse
Affiliation(s)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Antonio Di Bartolomeo
- Department of Physics 'E.R. Caianiello', University of Salerno, I-84084 Fisciano, Salerno, Italy
| |
Collapse
|
19
|
Garkani Nejad F, Asadi MH, Sheikhshoaie I, Dourandish Z, Zaimbashi R, Beitollahi H. Construction of modified screen-printed graphite electrode for the application in electrochemical detection of sunset yellow in food samples. Food Chem Toxicol 2022; 166:113243. [PMID: 35728724 DOI: 10.1016/j.fct.2022.113243] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/07/2022] [Accepted: 06/15/2022] [Indexed: 01/10/2023]
Abstract
The current work introduced a novel electrochemical sensor (screen-printed graphite electrode (SPGE) modified with MnO2 nanorods anchored graphene oxide nanocomposite (MnO2 NRs/GO) for sensitive determination of sunset yellow. The characterization of MnO2 NRs/GO nanocomposite synthesized through a simple hydrothermal approach was determined employing varied analytical equipment like Field emission-scanning electron microscopy (FE-SEM), Fourier transform infrared spectroscopy (FT-IR), and X-ray diffraction (XRD). Chronoamperometric measurements, differential pulse voltammetry (DPV), cyclic voltammetry (CV) and linear sweep voltammetry (LSV) were recruited to recognize the electrochemical oxidation of sunset yellow on the MnO2 NRs/GO/SPGE. The results of CV proved that the as-synthesized MnO2 NRs/GO nanocomposite has a good electrocatalytic activity toward sunset yellow. The MnO2 NRs/GO/SPGE electrode under optimized conditions using the DPV possessed a linear response for different concentrations of sunset yellow (between 0.01 and 115.0 μM) with a low limit of detection (LOD) (0.008 μM). Finally, the impressive applicability of this sensor was confirmed via real sample analysis with excellent recoveries (between 97.3 and 104.6%).
Collapse
Affiliation(s)
- Fariba Garkani Nejad
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, 76175-133, Iran
| | - Malek Hossein Asadi
- Department of Biotechnology, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, 76175-133, Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, 76175-133, Iran
| | - Reza Zaimbashi
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, 76175-133, Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| |
Collapse
|
20
|
A brief review on the recent achievements in electrochemical detection of folic acid. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2022. [DOI: 10.1007/s11694-022-01421-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
A reusable and sensitive electrochemical sensor for determination of Allura red in the presence of Tartrazine based on functionalized nanodiamond@SiO2@TiO2; an electrochemical and molecular docking investigation. Food Chem Toxicol 2022; 164:113080. [DOI: 10.1016/j.fct.2022.113080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/17/2022] [Accepted: 04/23/2022] [Indexed: 12/27/2022]
|
22
|
Kaleeswarran P, Koventhan C, Chen SM, Arumugam A. Coherent design of indium doped copper bismuthate-encapsulated graphene nanocomposite for sensitive electrochemical detection of Rutin. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.128740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
23
|
Karimi F, Hamidian Y, Behrouzifar F, Mostafazadeh R, Ghorbani-HasanSaraei A, Alizadeh M, Mortazavi SM, Janbazi M, Naderi Asrami P. An applicable method for extraction of whole seeds protein and its determination through Bradford's method. Food Chem Toxicol 2022; 164:113053. [PMID: 35460823 DOI: 10.1016/j.fct.2022.113053] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 04/12/2022] [Accepted: 04/16/2022] [Indexed: 01/15/2023]
Abstract
Analysis of protein content of food is necessary for quality control and is essential for precise labeling. Protein analysis is an issue of great economic and social fondness. Cereals are one of the most important sources of protein in food, livestock and poultry feed. In this article, the technique of extracting protein in 4 types of grains and measuring it by the Bradford method is discussed. The results obtained from this method are compared with the data obtained by the Kjeldahl method. This comparison showed that the Bradford method is more accurate in measuring proteins. Extraction of protein using NaOH at pH 13 can be used as a modified method to release proteins in soybean meal and consequently a Fast and accurate high-performance laboratory determination method for protein content via the Bradford method. The optimum pH value was identified as that of 13 in optimum temperature 40 °C for maximum protein extraction yield (43.6%, w/w). The new method used in this paper has resulted in the measurement of grain protein in the shortest time and with the least toxicity and the highest accuracy.
Collapse
Affiliation(s)
- Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran.
| | - Yasamin Hamidian
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran.
| | - Fatemeh Behrouzifar
- Skills and Entrepreneurship College, Qaemshahr Branch, Islamic Azad University, Qaemshahr, Iran; Nikan Salamat Kemend Khazar, Sari, Iran.
| | - Reza Mostafazadeh
- Department of Chemistry, Iran University of Science and Technology (IUST), Tehran, Iran
| | | | - Marzieh Alizadeh
- Pharmaceutical Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz, 71348-14336, Iran.
| | - Seyed-Morteza Mortazavi
- Department of Food Science and Technology, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran.
| | - Mobina Janbazi
- Department of Chemistry, Golestan University, Gorgan, Iran
| | | |
Collapse
|
24
|
Tajik S, Beitollahi H. Hydrothermal synthesis of CuFe 2O 4 nanoparticles for highly sensitive electrochemical detection of sunset yellow. Food Chem Toxicol 2022; 165:113048. [PMID: 35523384 DOI: 10.1016/j.fct.2022.113048] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 04/10/2022] [Accepted: 04/15/2022] [Indexed: 12/27/2022]
Abstract
The sunset yellow, as a synthetic food coloring azo dye, was detected in the present work using a new sensitive and selective sensor based on the modification of screen-printed electrode surface with Copper ferrite nanoparticles (CuFe2O4/SPE). Thus, a facile hydrothermal protocol was performed to prepare the CuFe2O4 nanoparticles, followed by characterization applying valid techniques, including Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS) and field-emission scanning electron microscopy (FE-SEM). Chronoamperometry, differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were employed to determine the electrochemical behavior of as-fabricated sensor. According to the electrochemical findings, a greater anodic peak current was found for the sunset yellow oxidation on the CuFe2O4/SPE than that on the unmodified SPE. The electrocatalytic response for the sunset yellow oxidation on the CuFe2O4/SPE in phosphate buffer (0.1 M, pH = 7.0) was effective, with an excellent sensitivity (0.1919 μA μM-1). There was a linear relationship between the voltammetric current and different sunset yellow concentrations (0.03-100.0 μM). The calculated limit of detection (LOD = 3Sb/m) for the sunset yellow was 0.009 μM.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran.
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| |
Collapse
|
25
|
Karimi F, Demir E, Aydogdu N, Shojaei M, Taher MA, Asrami PN, Alizadeh M, Ghasemi Y, Cheraghi S. Advancement in electrochemical strategies for quantification of Brown HT and Carmoisine (Acid Red 14) Drom Azo Dyestuff class. Food Chem Toxicol 2022; 165:113075. [PMID: 35487338 DOI: 10.1016/j.fct.2022.113075] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/16/2022] [Accepted: 04/22/2022] [Indexed: 12/24/2022]
Abstract
Brown HT and carmoisine, which are the most used dyestuffs in pharmaceuticals, textiles, cosmetics and foods, are important components of the Azo family. Although the Azo group is not toxic or carcinogenic under normal conditions, these dyestuffs require great care due to the reduction of the Azo functional group to amines. In particular, fast, reliable, easy, on-site and precise determinations of these substances are extremely necessary and important. In this review, the properties, applications, and electrochemical determinations of brown HT and carmoisine, which are used as synthetic food colorants, are discussed in detail. Up to now, sensor types, detection limits (LOD and LOQ), and analytical applications in the developed electrochemical strategies for both substances were compared. In addition, the validation parameters such as the variety of the sensors, sensitivity, selectivity and electrochemical technique in these studies were clarified one by one. While the electrochemical techniques recommended for brown HT were mostly used for the removal of dyestuff, for carmoisine they included fully quantitative centered studies. The percentiles of voltammetric techniques, which are the most widely used among these electroanalytical methods, were determined. The benefits of a robust electrochemical strategy for the determination of both food colors are summed up in this review. Finally, the brown HT and carmoisine suggestions for future perspectives in electrochemical strategy are given according to all their applications.
Collapse
Affiliation(s)
- Fatemeh Karimi
- Department of Chemical Engineering, Quhchan University of Technology, Quchan, Iran.
| | - Ersin Demir
- Afyonkarahisar Health Sciences University, Faculty of Pharmacy, Department of Analytical Chemistry, 03030, Afyonkarahisar, Turkey.
| | - Nida Aydogdu
- Afyonkarahisar Health Sciences University, Faculty of Pharmacy, Department of Analytical Chemistry, 03030, Afyonkarahisar, Turkey
| | - Moein Shojaei
- Department of Chemistry, Shahid Bahonar University of Kerman, Iran
| | - Mohammad A Taher
- Department of Chemistry, Shahid Bahonar University of Kerman, Iran
| | | | - Marzieh Alizadeh
- Department of Pharmaceutical Biotechnology and Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Younes Ghasemi
- Department of Pharmaceutical Biotechnology and Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Somaye Cheraghi
- Department of Chemistry, Shahid Bahonar University of Kerman, Iran.
| |
Collapse
|
26
|
Moradpour H, Beitollahi H, Nejad FG, Di Bartolomeo A. Glassy Carbon Electrode Modified with N-Doped Reduced Graphene Oxide Sheets as an Effective Electrochemical Sensor for Amaranth Detection. MATERIALS 2022; 15:ma15093011. [PMID: 35591345 PMCID: PMC9105645 DOI: 10.3390/ma15093011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 04/12/2022] [Accepted: 04/18/2022] [Indexed: 02/06/2023]
Abstract
Amaranth is one of the synthetic azo colorants used to improve the appearance and to increase the appeal of some foods and soft drinks. The excessive consumption of amaranth can be associated with health side effects, emphasizing the need to monitor this food dye. Accordingly, the present study aimed to introduce an electrochemical sensor of glassy carbon electrode (GCE) modified with N-doped reduced graphene oxide (N-rGO), N-rGO/GCE, to detect the amaranth sensitively and rapidly. Several electrochemical techniques such as differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), chronoamperometry (CHA), and cyclic voltammetry (CV) are exploited for the evaluation of the efficiency of the developed electrode for the detection of amaranth. We found that N-rGO/GCE enhanced amaranth oxidation, thus significantly elevating the current signal. Amaranth showed that calibration curves ranged from 0.1 to 600.0 µM, and the limit of detection (LOD) (S/N = 3) was 0.03 μM. Finally, the developed sensor was effectively applied for real samples (tap water, apple juice, and orange juice) with acceptable recovery values from 96.0 to 104.3%.
Collapse
Affiliation(s)
- Hediyeh Moradpour
- Department of Chemistry, Graduate University of Advanced Technology, Kerman 7631885356, Iran; (H.M.); (F.G.N.)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran
- Correspondence: (H.B.); (A.D.B.)
| | - Fariba Garkani Nejad
- Department of Chemistry, Graduate University of Advanced Technology, Kerman 7631885356, Iran; (H.M.); (F.G.N.)
| | - Antonio Di Bartolomeo
- Department of Physics “E.R. Caianaiello”, University of Salerno, 84084 Fisciano, Salerno, Italy
- Correspondence: (H.B.); (A.D.B.)
| |
Collapse
|
27
|
Şenocak A, Sanko V, Tümay SO, Orooji Y, Demirbas E, Yoon Y, Khataee A. Ultrasensitive electrochemical sensor for detection of rutin antioxidant by layered Ti 3Al 0.5Cu 0.5C 2 MAX phase. Food Chem Toxicol 2022; 164:113016. [PMID: 35430329 DOI: 10.1016/j.fct.2022.113016] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/06/2022] [Accepted: 04/11/2022] [Indexed: 12/12/2022]
Abstract
MAX phases have attracted great attention due to unique features such as thermal and electrical conductivity, easy fabrication, heat resistant, and lightweight. In this study, an easy and green method was employed to successfully develop a Ti3Al0.5Cu0.5C2 MAX phase structure, and a Ti3Al0.5Cu0.5C2 based glassy carbon electrode (GCE) was applied for the electrochemical determination of rutin antioxidants in mandarin and kiwi samples. The developed Ti3Al0.5Cu0.5C2 MAX phase was characterized by different techniques such as X-ray photoelectron spectroscopy (XPS), thermogravimetry and differential scanning calorimetry (TG-DSC), X-ray diffraction (XRD), Brunauer-Emmett-Teller (BET), diffuse reflectance spectroscopy (DRS), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) to obtain information on the structural and morphological properties. Electrochemical methods such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were employed for the determination of rutin using Ti3Al0.5Cu0.5C2/GCE. The GCE modified with Ti3Al0.5Cu0.5C2 demonstrated amplified electrochemical response (ca. 4.25 times) in comparison to the bare GCE towards rutin, and exhibited ultra-sensitivity and selectivity in the presence of other interfering antioxidants. Under the optimum conditions, good linearity in the range of 0.02-50.00 μmol L-1 was obtained for rutin analysis by the Ti3Al0.5Cu0.5C2-based sensor with a limit of detection (LOD, 3σ/K) as low as 0.015 μmol L-1. The fabricated Ti3Al0.5Cu0.5C2 MAX phase was applied to determine trace levels of rutin in mandarin and kiwi samples with validation by high-performance liquid chromatography (HPLC), thus highlighting its potential for the electrochemical determination of small molecules in the agricultural field.
Collapse
Affiliation(s)
- Ahmet Şenocak
- Department of Chemistry, Gebze Technical University, 41400, Gebze, Turkey
| | - Vildan Sanko
- Department of Chemistry, Gebze Technical University, 41400, Gebze, Turkey
| | - Süreyya Oğuz Tümay
- Department of Chemistry, Gebze Technical University, 41400, Gebze, Turkey
| | - Yasin Orooji
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China; Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, 210037, PR China.
| | - Erhan Demirbas
- Department of Chemistry, Gebze Technical University, 41400, Gebze, Turkey
| | - Yeojoon Yoon
- Department of Environmental and Energy Engineering, Yonsei University, Wonju, Republic of Korea.
| | - Alireza Khataee
- Department of Environmental Engineering, Gebze Technical University, 41400, Gebze, Turkey; Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran.
| |
Collapse
|
28
|
Beitollahi H, Tajik S, Di Bartolomeo A. Application of MnO2 Nanorod–Ionic Liquid Modified Carbon Paste Electrode for the Voltammetric Determination of Sulfanilamide. MICROMACHINES 2022; 13:mi13040598. [PMID: 35457903 PMCID: PMC9028730 DOI: 10.3390/mi13040598] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 04/03/2022] [Accepted: 04/08/2022] [Indexed: 02/01/2023]
Abstract
The current work introduced a convenient single-phase hydrothermal protocol to fabricate MnO2 nanorods (MnO2 NRs). Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Energy-dispersive X-ray spectroscopy (EDX) and field-emission scanning electron microscopy (FE-SEM) were used to determine the characteristics of MnO2 NR. Then, ionic liquid (IL) and MnO2 NRs were utilized to modify a carbon paste electrode (CPE) surface (MnO2NR-IL/CPE) to voltammetrically sense the sulfanilamide (SAA). An enhanced voltammetric sensitivity was found for the as-developed modified electrode toward SAA when compared with a bare electrode. The optimization experiments were designed to achieve the best analytical behavior of the SAA sensor. Differential pulse voltammetry (DPV) in the optimized circumstances portrayed a linear dependence on various SAA levels (between 0.07 and 100.0 μM), possessing a narrow detection limit (0.01 μM). The ability of the modified electrode to be used in sensor applications was verified in the determination of SAA present in the actual urine and water specimens, with impressive recovery outcomes.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran;
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
- Correspondence: (S.T.); (A.D.B.)
| | - Antonio Di Bartolomeo
- Physics Department “E.R. Caianiello”, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, Italy
- Correspondence: (S.T.); (A.D.B.)
| |
Collapse
|
29
|
Wen T, Nie Q, Han L, Gong Z, Li D, Ma Q, Wang Z, He W, Wen L, Peng H. Molecularly imprinted polymers-based piezoelectric coupling sensor for the rapid and nondestructive detection of infested citrus. Food Chem 2022; 387:132905. [PMID: 35447512 DOI: 10.1016/j.foodchem.2022.132905] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 03/22/2022] [Accepted: 04/04/2022] [Indexed: 11/04/2022]
Affiliation(s)
- Tao Wen
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Qiyi Nie
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Longbo Han
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Zhongliang Gong
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Dapeng Li
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Qiang Ma
- College of Science, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Zhiyu Wang
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Weitao He
- School of Mechanical and Electrical Engineering, Central South University of Forestry and Technology, Changsha, Hunan 410004, China
| | - Liang Wen
- College of Life Sciences, South China Normal University, Guangzhou, Guangdong 510630, China
| | - Hailong Peng
- Department of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, Jiangxi, China.
| |
Collapse
|
30
|
Jahani PM, Aflatoonian MR, Rayeni RA, Di Bartolomeo A, Mohammadi SZ. Graphite carbon nitride-modified screen-printed electrode as a highly sensitive and selective sensor for detection of amaranth. Food Chem Toxicol 2022; 163:112962. [DOI: 10.1016/j.fct.2022.112962] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/12/2022] [Accepted: 03/22/2022] [Indexed: 12/27/2022]
|
31
|
Alizadeh M, Demir E, Aydogdu N, Zare N, Karimi F, Kandomal SM, Rokni H, Ghasemi Y. Recent advantages in electrochemical monitoring for the analysis of amaranth and carminic acid food colors. Food Chem Toxicol 2022; 163:112929. [PMID: 35307455 DOI: 10.1016/j.fct.2022.112929] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 03/09/2022] [Accepted: 03/15/2022] [Indexed: 12/19/2022]
Abstract
This study provides a comprehensive review of the latest developments in the electrochemical impressions of the important dyestuffs including amaranth and carminic acid. Food colors are organic substances that have important effects on human health and food safety. While these substances do not pose a problem when used in the daily intake (ADI) amounts, they harm human health when consumed excessively. Amaranth and carminic acid are synthetic and natural food colors ingredients, respectively. Analysis of these substances in food, pharmaceutical, cosmetic and textile samples is extremely important because of their genotoxicity, cytostatic and cytotoxic effects. Electroanalytical methods, which have great advantages over traditional analytical methods, shed light on the scientific world. Electrochemical monitoring modules, which are fast, simple, accurate, reliable, and highly selective, are promising for the determination of both substances. Until now, amaranth and carminic acid food determinations have been carried out successfully with electrochemical monitoring techniques in many numbers in the literature. Voltammetric techniques are the most widely used among these electroanalytical methods. In particular, square wave and differential pulse voltammetric techniques, which have extraordinary properties, have been heavily preferred. Limits of detection (LOD) comparable to the standard analytical method have been achieved using these methods, which have very quick analysis durations, high precision and accuracy, do not require long preprocessing, and have great selectivity. In addition, more sensitive and selective analyses of amaranth and carminic acid in natural samples were carried out with numerous indicator electrodes. The merits of powerful electrochemical monitoring studies for the determination of both food colors during the last decade are presented in this study. Moreover, parameters such as analytical applications, detection limits, electrochemical methods, selectivity, working electrodes, and working ranges are summarized in detail.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Pharmaceutical Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz, 71348-14336, Iran
| | - Ersin Demir
- Afyonkarahisar Health Sciences University, Faculty of Pharmacy, Department of Analytical Chemistry, 03030, Afyonkarahisar, Turkey.
| | - Nida Aydogdu
- Afyonkarahisar Health Sciences University, Faculty of Pharmacy, Department of Analytical Chemistry, 03030, Afyonkarahisar, Turkey
| | - Najmeh Zare
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran
| | - Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - S Masoud Kandomal
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran
| | - Hassan Rokni
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran
| | - Younes Ghasemi
- Pharmaceutical Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
32
|
Determination of Lorazepam Using the Electrocatalytic Effect of NiO/SWCNTs Modified Carbon Paste Electrode as a Powerful Sensor. Top Catal 2022. [DOI: 10.1007/s11244-022-01561-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
33
|
Afshar EA, Taher MA. New fabrication of CuFe2O4/PAMAM nanocomposites by an efficient removal performance for organic dyes: Kinetic study. ENVIRONMENTAL RESEARCH 2022; 204:112048. [PMID: 34536375 DOI: 10.1016/j.envres.2021.112048] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 09/01/2021] [Accepted: 09/05/2021] [Indexed: 06/13/2023]
Abstract
Today, removing pollutants from water sources is essential because of the population increase and the growing need for safe drinking water. Dyes are one of the most critical pollutants from industrial effluents such as paper and textile industries that profoundly affect the environment. There are several ways to remove environmental contaminants. Magnetic nanoparticles have a high ability to adsorb dyes. Of course, increasing the interaction between magnetic nanomaterials and pollutants is also essential, which can be done using porous materials such as dendrimers. In this work, the synthesis of CuFe2O4 magnetite nanoparticles within the polyamidoamine dendrimers structure was used as an efficient sorbent to remove both alizarin reds (ARS) and brilliant green (BG) dyes. Moreover, various parameters for dyes removal were studied. The optimum removal conditions were obtained for ARS within 30 min at a sorbent dose of 2 mg per 5 mL for the initial dye concentration of 7.0 ppm in pH 6 at 25 °C, and for BG within 45 min at a sorbent dose of 5 mg per 5 mL for the initial dye concentration of 17.0 ppm in pH 8 at 25 °C. At the optimum values of the above parameters, both dyes' removal efficiency was more than 97%. Also, the obtained results showed that the adsorption isotherm follows the Langmuir model and Temkin model for ARS and BG, respectively. This method was successfully used for the removal of both dyes in water samples.
Collapse
Affiliation(s)
- Elham Ashrafzadeh Afshar
- Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran; Young Research Societies, Shahid Bahonar University of Kerman, Kerman, Iran.
| | - Mohammad Ali Taher
- Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran.
| |
Collapse
|
34
|
Mehmandoust M, Uzcan F, Soylak M, Erk N. Dual-response electrochemical electrode for sensitive monitoring of topotecan and mitomycin as anticancer drugs in real samples. CHEMOSPHERE 2022; 291:132809. [PMID: 34785182 DOI: 10.1016/j.chemosphere.2021.132809] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/25/2021] [Accepted: 11/04/2021] [Indexed: 06/13/2023]
Abstract
This research paper employed an innovative electrochemical electrode to simultaneously determine topotecan (TPT) and mitomycin (MMC) as anticancer agents. For this purpose, a novel nanocomposite was synthesized using a hydrothermal procedure. The nanocomposites were characterized using FTIR, STEM, FESEM, mapping analysis, EDX, and XRD methods. The novelty of this work is the successful synthesis of Fe3O4 decorated on the surface of CuCo2S4 (Fe3O4@CuCo2S4) nanocomposites showed two separate anodic peaks at 0.8 V for TPT and 1.0 V for MMC with potential separation of 0.2 V. This was enough for the simultaneous electrochemical determination of topotecan and mitomycin on a glassy carbon electrode (GCE), simultaneously. At optimized conditions, the developed electrode exhibited linear responses with TPT and MMC concentration in the ranges of 0.01-0.89 and 0.89-8.95 μM for topotecan and 0.1-19.53 μM for mitomycin. The detection limits were observed as 6.94 nM and 80.00 nM for topotecan and mitomycin, respectively. The fabricated Fe3O4@CuCo2S4/GCE showed high sensitivity, long-term stability, and repeatability towards the sensing of TPT and MMC simultaneously and can be utilized in real samples. The obtained results confirmed that the fabricated Fe3O4@CuCo2S4/GCE nanocomposites can be utilize in the simultaneous electrochemical determination of topotecan and mitomycin in real samples.
Collapse
Affiliation(s)
- Mohammad Mehmandoust
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey; Sakarya University, Biomaterials, Energy, Photocatalysis, Enzyme Technology, Nano & Advanced Materials, Additive Manufacturing, Environmental Applications, and Sustainability Research & Development Group (BIOENAMS R&D Group), 54187, Sakarya, Turkey.
| | - Furkan Uzcan
- Erciyes University, Faculty of Sciences, Department of Chemistry, 38039, Kayseri, Turkey; Technology Research & Application Center (TAUM), Erciyes University, 38039, Kayseri, Turkey
| | - Mustafa Soylak
- Erciyes University, Faculty of Sciences, Department of Chemistry, 38039, Kayseri, Turkey; Technology Research & Application Center (TAUM), Erciyes University, 38039, Kayseri, Turkey; Turkish Academy of Sciences (TUBA), Cankaya, Ankara, Turkey
| | - Nevin Erk
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey; Sakarya University, Biomaterials, Energy, Photocatalysis, Enzyme Technology, Nano & Advanced Materials, Additive Manufacturing, Environmental Applications, and Sustainability Research & Development Group (BIOENAMS R&D Group), 54187, Sakarya, Turkey.
| |
Collapse
|
35
|
Piezoelectric sensing of glucose oxidase activity of Aspergillus niger spores pretreated by different methods. Food Chem 2022; 370:130901. [PMID: 34500289 DOI: 10.1016/j.foodchem.2021.130901] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 08/14/2021] [Accepted: 08/16/2021] [Indexed: 11/23/2022]
Abstract
The development of Aspergillus niger (A. niger) spores as glucose oxidase (GOD) biocatalysts to produce gluconic acid is highly anticipated in the food industry. Herein, a piezoelectric sensor (PIS) method has been developed for the detection of GOD activity and better application of rapid screening of GOD activity in A. niger spores. The GOD activity detection is based on GOD catalyzing β-d-glucose to produce gluconic acid, which results in frequency shift changes recorded by the PIS device in real-time. Using the PIS method, the kinetic parameter 6.5 mg/mL, the correlation equation υ0=31.92CGOD+1.04, the recoveries (89.4%-93.9%, and their RSDs were all within 6.1%) and the optimal GOD activity in A. niger spores under different treatment conditions was obtained. Compared with the classical methods, the proposed method is accurate, rapid, convenient and does not require additional reagents. It has a broad range of potential applications for exploring new GOD biocatalysts.
Collapse
|
36
|
El-Said WA, Qaisi RM, Placide V, Choi JW. A stable naked-eye colorimetric sensor for monitoring release of extracellular gamma-aminobutyric acid (GABA) neurotransmitter from SH-SY5Y cells. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120517. [PMID: 34739892 DOI: 10.1016/j.saa.2021.120517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 10/04/2021] [Accepted: 10/14/2021] [Indexed: 06/13/2023]
Abstract
A novel optical γ-aminobutyric acid (GABA)-based sensor was developed on interacting thiol compounds and o-phthalaldehyde (OPA) to form thiacetal compounds. Then, the thiacetal interacts with the GABA molecule to form an isoindole compound. The effects of four thiol compounds on the stability of the resulting isoindole compound were assessed. The 2-mercaptoethanol, "one of the most used derivatizing agents," is unexpectedly the least stable; while, 16-mercaptohexadecanoic acid resulted in the most durable isoindole compound. The developed sensor showed the capability for detecting GABA within a wide concentration range spanning from 500 nmol L-1 to 100 µmol L-1. The detection limit was about 330 nmol L-1, which indicated the high sensitivity of the developed sensor compared with those previously reported. The findings illustrated the ability to detect GABA at the physiological pH (pH = 7.4) without adjusting the pH value, opening the door for real applications. Furthermore, the sensor could detect various GABA concentrations in human serum with good recovery percentages (98% to 101.4%). In addition, this assay was applied to monitor GABA release from the SH-SY5Y cell line to convert glutamate into GABA. This result indicates the capability of the proposed assay for visually monitoring the release of GABA neurotransmitters.
Collapse
Affiliation(s)
- Waleed A El-Said
- Department of Chemistry, College of Science, University of Jeddah, P.O. Box 80327, Jeddah 21589, Saudi Arabia; Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 121-742, Republic of Korea; Department of Chemistry, Faculty of Science, Assiut University, Assiut 71516, Egypt
| | - Ramy M Qaisi
- University of Jeddah, College of Engineering, Department of Electrical and Electronic Engineering, P.O. Box 80327, Jeddah 21589, Saudi Arabia
| | - Virginie Placide
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 121-742, Republic of Korea
| | - Jeong-Woo Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 121-742, Republic of Korea.
| |
Collapse
|
37
|
Tabrizi M, Shahidi SA, Chekin F, Ghorbani-HasanSaraei A, Raeisi SN. Reduce Graphene Oxide/Fe3O4 Nanocomposite Biosynthesized by Sour Lemon Peel; Using as Electro-catalyst for Fabrication of Vanillin Electrochemical Sensor in Food Products Analysis and Anticancer Activity. Top Catal 2022. [DOI: 10.1007/s11244-021-01541-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
38
|
Fe3O4@Au-rGO Nanocomposite/Ionic Liquid Modified Sensor for Ultrasensitive and Selective Sensing of Doxorubicin. Top Catal 2022. [DOI: 10.1007/s11244-021-01504-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
39
|
Shahsavari M, Mortazavi M, Tajik S, Sheikhshoaie I, Beitollahi H. Synthesis and Characterization of GO/ZIF-67 Nanocomposite: Investigation of Catalytic Activity for the Determination of Epinine in the Presence of Dobutamine. MICROMACHINES 2022; 13:88. [PMID: 35056253 PMCID: PMC8781755 DOI: 10.3390/mi13010088] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/24/2021] [Accepted: 01/03/2022] [Indexed: 02/04/2023]
Abstract
In this study, we prepared graphene oxide (GO)/ZIF-67 nanocomposites. Therefore, GO/ZIF-67 nanocomposites were used as a modifier on a screen-printed electrode (GO/ZIF-67/SPE) for studying the electrochemical behavior of epinine in phosphate buffer saline (PBS) at pH 7.0 with voltammetry techniques. The GO/ZIF-67/SPE showed greater electrocatalytic activities than the bare SPE. As a result, the GO/ZIF-67/SPE was utilized for additional electrochemical examinations. The epinine concentration determination was in the range 9.0 × 10-8 M to 5.0 × 10-4 M, and the limit of detection (LOD) as well as the limit of quantification (LOQ) equaled 2.0 and 6.6 nM, respectively. From the scan rate study, the oxidation of epinine was found to be diffusion-controlled, and the simultaneous detection of epinine and dobutamine were well achieved with the differential pulse voltammetric (DPV) technique. Moreover, the stability and reproducibility of epinine at the GO/ZIF-67/SPE was studied, and the use of the GO/ZIF-67/SPE to detect epinine and dobutamine in real samples was furthermore successfully demonstrated.
Collapse
Affiliation(s)
- Mahboobeh Shahsavari
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 7616914111, Iran; (M.S.); (I.S.)
| | - Mojtaba Mortazavi
- Biotechnology Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran;
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 7616913555, Iran
| | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 7616914111, Iran; (M.S.); (I.S.)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran
| |
Collapse
|
40
|
Liu G, Yang X, Ye W, Zhu J, Xie K, Fu L. Application of Solid-state Electrochemical Analysis in Ancient Ceramic
Identification and Characterization: A Review. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999200806155426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Ceramics can reflect ancient technology and art, therefore, it has a very important position in
archaeology. However, it is far from enough just to study the shape of pottery and porcelain. It is necessary to use advanced
scientific and technological means to conduct a comprehensive analysis of pottery and porcelain, so as to study the
information hidden deep in the remains of ceramic objects.
Methods:
The solid voltammetric method can be used to obtain information about the composition of materials used in
ancient ceramics. This new method can be applied to insoluble solids for example, providing qualitative and quantitative
information and structural information with little soluble solids. The method requires only ng-μg sample.
Results:
In this review, we first describe the development of solid-state voltammetric method and our work in this field.
Then, we describe in detail the application of this method in archaeology, especially in the analysis of ceramics. Finally, we
describe the analytical applications of other electrochemical techniques for ceramics analysis.
Conclusion:
Due to the low demand for samples and the high-cost performance of analytical instruments, this method has
been widely studied in Europe. To sum up, we propose to establish a microsampling method for ancient ceramics. A new
method for the protection of fine ancient ceramics by the suitable carrier and the fixation on the surface of the electrode.
These improvements can enable solid-state electroanalytical chemistry technology to achieve more comprehensive and
accurate quantitative analysis of ancient ceramics particles. We also propose the current challenges and future directions of
solid-state electroanalytical chemistry.
Collapse
Affiliation(s)
- Guangfu Liu
- Henan Key Laboratory of Research for Central Plains Ancient Ceramics, Pingdingshan University, Pingdingshan
Henan, 467000 P.R. China
| | - Xinghua Yang
- Henan Key Laboratory of Research for Central Plains Ancient Ceramics, Pingdingshan University, Pingdingshan
Henan, 467000 P.R. China
| | - Weiting Ye
- College of Materials and Environmental Engineering, Hangzhou Dianzi University,
Hangzhou 310018, P.R. China
| | - Jiangwei Zhu
- Collaborative Innovation Center of Sustainable Forestry in Southern China of Jiangsu Province, (Nanjing Forestry University), Nanjing 210037,China
| | - Kefeng Xie
- School of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, 730070,China
| | - Li Fu
- Henan Key Laboratory of Research for Central Plains Ancient Ceramics, Pingdingshan University, Pingdingshan
Henan, 467000 P.R. China
| |
Collapse
|
41
|
Montazarolmahdi M, Masrournia M, Nezhadali A. Determination of Salicylic Acid Using a Highly Sensitive and New
Electroanalytical Sensor. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411017666210111095822] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
A drug sensor (salicylic acid, in this case) was designed and made up of this research. The senor
was made by modification of paste electrode (MPE) with CuO-SWCNTs and 1-hexyl-3-methylimidazolium chloride
(HMICl). The MPE/CuO-SWCNTs/HMICl showed catalytic activity for the oxidation signal of salicylic acid in
phosphate buffer solution.
Methods:
Electrochemical methods were used as a powerful strategy for the determination of salicylic acid in
pharmaceutical samples. Aiming at this goal, carbon paste electrode was amplified with conductive materials and used as
a working electrode.
Results:
The MPE/CuO-SWCNTs/HMICl was used for the determination of salicylic acid in the concentration range of
1.0 nM – 230 µM using differential pulse voltammetric (DPV) method. At pH=7.0, as optimum condition, the MPE/CuOSWCNTs/HMICl displayed a high-quality ability for the determination of salicylic acid in urine, pharmaceutical serum,
and water samples.
Conclusion:
The MPE/CuO-SWCNTs/HMICl was successfully used as a new and high performance working electrode
for the determination of salicylic acid at a nanomolar level and in real samples.
Collapse
|
42
|
Mousazadeh F, Mohammadi SZ, Akbari S, Mofidinasab N, Aflatoonian MR, Shokooh-Saljooghi A. Recent Advantages of Mediator Based Chemically Modified Electrodes;
Powerful Approach in Electroanalytical Chemistry. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411017999201224124347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Modified electrodes have advanced from the initial studies aimed at understanding
electron transfer in films to applications in areas such as energy production and analytical
chemistry. This review emphasizes the major classes of modified electrodes with mediators
that are being explored for improving analytical methodology. Chemically modified electrodes
(CMEs) have been widely used to counter the problems of poor sensitivity and selectivity faced in
bare electrodes. We have briefly reviewed the organometallic and organic mediators that have been
extensively employed to engineer adapted electrode surfaces for the detection of different compounds.
Also, the characteristics of the materials that improve the electrocatalytic activity of the
modified surfaces are discussed.
Objective:
Improvement and promotion of pragmatic CMEs have generated a diversity of novel
and probable strong detection prospects for electroanalysis. While the capability of handling the
chemical nature of the electrode/solution interface accurately and creatively increases , it is predictable
that different mediators-based CMEs could be developed with electrocatalytic activity and
completely new applications be advanced.
Collapse
Affiliation(s)
| | | | - Sedighe Akbari
- Islamic Azad University, Shahrbabak Branch, Shahrbabak,Iran
| | | | - Mohammad Reza Aflatoonian
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman,Iran
| | | |
Collapse
|
43
|
Alizadeh M, Nodehi M, Salmanpour S, Karimi F, Sanati AL, Malekmohammadi S, Zakariae N, Esmaeili R, Jafari H. Properties and Recent Advantages of N,N’-dialkylimidazolium-ion Liquids
Application in Electrochemistry. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999201022141930] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
:
N,Nʹ-dialkylimidazolium-ion liquids is one of the important ionic liquids with a wide range of application as
conductive electrolyte and in electrochemistry. The modified electrodes create a new view in fabrication of
electroanalytical sensors. Many modifiers have beeen suggested for modification of electroanalytical sensor since many
years ago. Over these years, ionic liquids and especially room temperature ionic liquids have attracted more attention due
to their wide range of electrochemical windows and high electrical conductivity. N,Nʹ-dialkylimidazolium-ion liquids are
one of the main important ionic liquids suggested for modification of bare electrodes and especially carbon paste
electrodes. Although many review articles have reported onthe use of ionic liquids in electrochemical sensors, no review
article has been specifically introduced so far on the review of the advantages of N,Nʹ-dialkylimidazolium ionic liquid.
Therefore, in this review paper we focused on the introduction of recent advantages of N,Nʹ-dialkyl imidazolium ionic
liquid in electrochemistry.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz,
PO Box: 71348-14336, Iran
| | - Marzieh Nodehi
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, PO. Box 397, Sabzevar,Iran
| | - Sadegh Salmanpour
- Department of Chemistry, Sari Branch, Islamic Azad University, Sari,Iran
| | - Fatemeh Karimi
- Nanostructure Based Biosensors Research Group, Ton Duc Thang University, Ho Chi Minh City,Vietnam
| | - Afsaneh L. Sanati
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Technology, Quchan,Iran
| | - Samira Malekmohammadi
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Technology, Quchan,Iran
| | - Nilofar Zakariae
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran,Iran
| | - Roghayeh Esmaeili
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran,Iran
| | - Hedayat Jafari
- Traditional and Complementary Medicine Research Center, Addiction Institute, Mazandaran University of Medical Sciences, Sari,Iran
| |
Collapse
|
44
|
Shahraki S, Masrournia M, Karimi-Maleh H. Fabrication of Electrochemical Sensor for Epinine Determination
Amplified with MgO/CNTs Nanocomposite and Ionic Liquid. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411017666210303091301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Catecholamines are a large group of pharmacological and biological compounds
that are widely used in biological systems. These compounds are prepared both naturally
and synthetically with many key roles in the human body and its activities. Therefore, many researchers
focused on the identification and determination of catecholamines in biological samples.
Methods:
MgO/SWCNTs were synthesized through the chemical precipitation method. In addition,
cyclic voltammetry, differential pulse voltammetry, and chronoamperometric methods were used
for the electro-oxidation reaction study of epinine at the surface of the modified electrode.
Results:
Carbon paste electrode (CPE) modified with MgO/SWCNTs nanocomposite and 1-butyl-
3-methylimidazolium methanesulfonate (BMMS) was used as an electrochemical sensor for the
determination of epinine. The results showed a linear dynamic range of 5.0 nM-250 μM with a
detection limit of 0.1 nM for epinine determination using MgO/SWCNTs/BMMS/CPE as a sensor.
Conclusion:
In the present study, a highly sensitive electrochemical sensor was designed and fabricated
as an analytical tool for the determination of epinine. MgO/SWCNTs/BMMS/CPE was
successfully used for the determination of epinine in water and dextrose saline with an acceptable
recovery range of 98.7%-102.72%.
Collapse
Affiliation(s)
- Shirin Shahraki
- Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad,Iran
| | | | - Hassan Karimi-Maleh
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Advanced Technology, Quchan,Iran
| |
Collapse
|
45
|
Baghbaderani SS, Mokarian P, Moazzam P. A Review on Electrochemical Sensing of Cancer Biomarkers Based on
Nanomaterial - Modified Systems. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999200917161657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Diagnosis of cancer in the early stages can help treat efficiently and reduce cancerrelated
death. Cancer biomarkers can respond to the presence of cancer in body fluids before the
appearance of any other symptoms of cancer. The integration of nanomaterials into biosensors as
electrochemical platforms offer rapid, sensitive detection for cancer biomarkers. The use of surface-
modified electrodes by carbon nanomaterials and metal nanoparticles enhances the performance
of electrochemical analysis in biosensing systems through the increase of bioreceptors loading
capacity on the surface. In this review, novel approaches based on nanomaterial-modified systems
in the point of care diagnostics are highlighted.
Collapse
Affiliation(s)
- Sorour Salehi Baghbaderani
- Department of Nanotechnology Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan 81746-73441,Iran
| | - Parastou Mokarian
- Department of Biology, Faculty of Sciences, Central Tehran Branch, Islamic Azad University, Tehran 14676-86831,Iran
| | - Parisa Moazzam
- School of Chemistry, University of New South Wales, Sydney, 2052,Australia
| |
Collapse
|
46
|
Shokouhi M, Vahidi M, Abbasghorbani M. Investigation of H2S Solubility in Aqueous N- Methyldiethanolamine + Amine Functionalized UiO-66 as a nano solvent. MAIN GROUP CHEMISTRY 2021. [DOI: 10.3233/mgc-210086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
In this paper, the experimental solubility of hydrogen sulfide in aqueous N- Methyldiethanolamine + Amine Functionalized UiO-66 (UiO-66-NH2) was studied. UiO-66-NH2 was produced using solvothermal process, and its physicochemical properties were investigated by different techniques including XRD, TGA, TEM, BET, and FTIR to realize its crystalline structure, morphology, thermal stability, and porous structure. The Zeta potential of the solution was turned out to be about 26.6 mV (millivolt), meaning that UiO-66-NH2 particles are moderately stable in aqueous 40 wt.% MDEA. The solubility of hydrogen sulfide has been carried out using the isochoric saturation / or static method in two concentration grades of 0.1 and 0.5 wt.% of UiO-66-NH2 in the aqueous solution of 40 wt.% MDEA known as nanofluid. Experimental measurements were carried out at temperatures of 303.15 through 333.15 K, and pressures up 1100 kPa. Results showed that the addition of UiO-66-NH2 nanoparticles to the MDEA solution altered the results less than 3% , while the mean value of uncertainty reported in this work is about 4% , meaning that the addition of nanoparticles do not have remarkable effect on H2S solubility. In contrast, it causes an increased capacity of CO2 absorption of that solution up to 10% .
Collapse
Affiliation(s)
- Mohammad Shokouhi
- Gas Science Department, Gas Research Division, Research Institute of Petroleum Industry (RIPI), Tehran, Iran
| | - Mehdi Vahidi
- Gas Science Department, Gas Research Division, Research Institute of Petroleum Industry (RIPI), Tehran, Iran
| | - Maryam Abbasghorbani
- Gas Science Department, Gas Research Division, Research Institute of Petroleum Industry (RIPI), Tehran, Iran
| |
Collapse
|
47
|
Zhao X, Shen Y, Yan M, Yuan Z. Flavonoid profiles in peels and arils of pomegranate cultivars. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2021. [DOI: 10.1007/s11694-021-01216-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
48
|
Huang C, Wang H, Ma S, Bo C, Ou J, Gong B. Recent application of molecular imprinting technique in food safety. J Chromatogr A 2021; 1657:462579. [PMID: 34607292 DOI: 10.1016/j.chroma.2021.462579] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 09/21/2021] [Accepted: 09/22/2021] [Indexed: 12/22/2022]
Abstract
Due to the extensive use of chemical substances such as pesticides, antibiotics and food additives, food safety issues have gradually attracted people's attention. The extensive use of these chemicals seriously damages human health. In order to detect trace chemical residues in food, researchers have to find several simple, economical and effective tools for qualitative and quantitative analysis. As a kind of material that specifically and selectively recognize template molecules from real samples, molecular imprinting technique (MIT) has widely applied in food samples analysis. This article mainly reviews the application of molecularly imprinted polymer (MIP) in the detection of chemical residues from food in the past five years. Some recent and novel methods for fabrication of MIP are reviewed. Their application of sample pretreatment, sensors, etc. in food analysis is reviewed. The application of molecular imprinting in chromatographic stationary phase is referred. Additionally, the challenges faced by MIP are discussed.
Collapse
Affiliation(s)
- Chao Huang
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan 750021, China
| | - Hongwei Wang
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan 750021, China
| | - Shujuan Ma
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Chunmiao Bo
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan 750021, China
| | - Junjie Ou
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan 750021, China; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China; University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Bolin Gong
- School of Chemistry and Chemical Engineering, Key Laboratory for Chemical Engineering and Technology, State Ethnic Affairs Commission, North Minzu University, Yinchuan 750021, China.
| |
Collapse
|
49
|
A novel, sensitive and selective nanosensor based on graphene nanoribbon–cobalt ferrite nanocomposite and 1-methyl-3-butylimidazolium bromide for detection of vanillin in real food samples. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2021. [DOI: 10.1007/s11694-021-01180-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
50
|
Hareesha N, Manjunatha J, Amrutha B, Sreeharsha N, Basheeruddin Asdaq S, Anwer MK. A fast and selective electrochemical detection of vanillin in food samples on the surface of poly(glutamic acid) functionalized multiwalled carbon nanotubes and graphite composite paste sensor. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127042] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|