1
|
Bodur SE, Ayan GN, Bodur S, Günkara ÖT, Bakırdere S. Determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry after its preconcentration by simple liquid-phase microextraction. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:454. [PMID: 38622372 DOI: 10.1007/s10661-024-12544-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 03/16/2024] [Indexed: 04/17/2024]
Abstract
This work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 μg kg-1, 150.6 μg kg-1, 45.2 μg kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.
Collapse
Affiliation(s)
- Sezin Erarpat Bodur
- Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye
| | - Gizem Nur Ayan
- Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye
| | - Süleyman Bodur
- Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye
- Faculty of Pharmacy, Department of Analytical Chemistry, İstinye University, 34010, İstanbul, Türkiye
- Scientific and Technological Research Application and Research Center, İstinye University, 34010, İstanbul, Türkiye
| | - Ömer Tahir Günkara
- Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye.
| | - Sezgin Bakırdere
- Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye.
- Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, Çankaya, 06670, Ankara, Türkiye.
| |
Collapse
|
2
|
Development and Factorial Experimental Design Optimization of Deep Eutectic Solvent‐Based Microextraction of Carmoisine (E122) in Candy and Water Samples. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2158194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
3
|
Gösterişli TU, Oflu S, Keyf S, Bakırdere S. Development of a double monitoring system for the determination of Cr(VI) in different water matrices by HPLC-UV and digital image-based colorimetric detection method with the help of a metal sieve-linked double syringe system in complexation. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:691. [PMID: 35984528 DOI: 10.1007/s10661-022-10392-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 08/12/2022] [Indexed: 06/15/2023]
Abstract
This study reports a cheap, efficient, sensitive, and simple double monitoring analytical method for trace determination of Cr(VI), which is toxic and harmful even at very low concentrations. A metal sieve-linked double syringe (MSLDS) system was used to help the formation of chromium complex (Cr-diphenyl carbazide, DPC) subsequently determined by high-performance liquid chromatography-ultraviolet (HPLC-UV) and digital image-based colorimetry (DIC) systems. The metal complex was eluted through a Phenomenex-Aqua C18 with a mobile phase comprising of 50 mM ammonium formate solution (pH 4.0):acetonitrile (78:22, v/v) and detected by the UV detector at the wavelength of 581 nm. Under their optimum conditions, the HPLC-UV and DIC systems exhibited good linearity in ranges of 10-500 µg L-1 and 100-1000 µg L-1, respectively. The percent relative standard deviations (RSD%s) calculated for the lowest concentrations of both systems fell below 10%, and this confirmed good repeatability for replicate measurements. The accuracy of the proposed methods was evaluated by performing spike recovery experiments on wastewater, river water, and tap water samples. The calculated recovery results were in the range of 81.5-105.5% for HPLC-UV system and 93.8-111.1% for the DIC system. These results indicate that the proposed methods are suitable for routine Cr(VI) determination in terms of their rapidness, simplicity, good repeatability, and low cost.
Collapse
Affiliation(s)
| | - Sude Oflu
- Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye
| | - Seyfullah Keyf
- Department of Chemical Engineering, Yıldız Technical University, 34220, İstanbul, Türkiye
| | - Sezgin Bakırdere
- Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye.
- Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Ankara, Türkiye.
| |
Collapse
|
4
|
Liu W, Chen Y, Yin X, Liu F, Li W, Yu J, Jing G, Li W. A Rapid and on-Site detection of Pesticide Residue from Fruit Samples based on Surface Swab-Electrospray Ionization-Ion Mobility Spectrometry. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
5
|
Wang X, Han Y, Cao J, Yan H. Headspace solid-phase-microextraction using a graphene aerogel for gas chromatography–tandem mass spectrometry quantification of polychlorinated naphthalenes in shrimp. J Chromatogr A 2022; 1672:463012. [DOI: 10.1016/j.chroma.2022.463012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/27/2022] [Accepted: 03/30/2022] [Indexed: 10/18/2022]
|