• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623447)   Today's Articles (3197)   Subscriber (49408)
For: Cedraro A, Cappello A, Chiari L. A portable system for in-situ re-calibration of force platforms: theoretical validation. Gait Posture 2008;28:488-94. [PMID: 18450453 DOI: 10.1016/j.gaitpost.2008.03.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2007] [Revised: 02/14/2008] [Accepted: 03/05/2008] [Indexed: 02/02/2023]
Number Cited by Other Article(s)
1
Bartlett KA, Forth KE, Layne CS, Madansingh S. Validating a low-cost, consumer force-measuring platform as an accessible alternative for measuring postural sway. J Biomech 2019;90:138-142. [PMID: 31097188 DOI: 10.1016/j.jbiomech.2019.04.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 03/24/2019] [Accepted: 04/27/2019] [Indexed: 10/26/2022]
2
In-situ force plate calibration: 12 years' experience with an approach for correcting the point of force application. Gait Posture 2017;58:98-102. [PMID: 28763716 DOI: 10.1016/j.gaitpost.2017.07.111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 07/19/2017] [Accepted: 07/20/2017] [Indexed: 02/02/2023]
3
Anatomical calibration for wearable motion capture systems: Video calibrated anatomical system technique. Med Eng Phys 2015;37:813-9. [PMID: 26077101 DOI: 10.1016/j.medengphy.2015.05.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2015] [Revised: 05/05/2015] [Accepted: 05/18/2015] [Indexed: 11/24/2022]
4
Cappello A, Bagalà F, Chiari L. Re: A new device for in situ static and dynamic calibration of force platforms by Hsieh et al. [Gait and Posture 33 (2011) 701-705]. Gait Posture 2012;36:653-4. [PMID: 22727719 DOI: 10.1016/j.gaitpost.2012.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2011] [Accepted: 05/30/2012] [Indexed: 02/02/2023]
5
Cappello A, Bagalà F, Cedraro A, Chiari L. Non-linear re-calibration of force platforms. Gait Posture 2011;33:724-6. [PMID: 21392999 DOI: 10.1016/j.gaitpost.2011.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2010] [Revised: 02/04/2011] [Accepted: 02/14/2011] [Indexed: 02/02/2023]
6
Blanchard Sanhueza G. Test system for clinical force platforms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010;2010:5772-5775. [PMID: 21097339 DOI: 10.1109/iembs.2010.5627840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
7
Cedraro A, Cappello A, Chiari L. A portable system for in-situ re-calibration of force platforms: experimental validation. Gait Posture 2009;29:449-53. [PMID: 19111467 DOI: 10.1016/j.gaitpost.2008.11.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Revised: 09/26/2008] [Accepted: 11/04/2008] [Indexed: 02/02/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA