1
|
de Lima Gonçalves V, Ribeiro CT, Cavalheiro GL, Zaruz MJF, da Silva DH, Milagre ST, de Oliveira Andrade A, Pereira AA. A hybrid linear discriminant analysis and genetic algorithm to create a linear model of aging when performing motor tasks through inertial sensors positioned on the hand and forearm. Biomed Eng Online 2023; 22:98. [PMID: 37845723 PMCID: PMC10580547 DOI: 10.1186/s12938-023-01161-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 10/01/2023] [Indexed: 10/18/2023] Open
Abstract
BACKGROUND During the aging process, cognitive functions and performance of the muscular and neural system show signs of decline, thus making the elderly more susceptible to disease and death. These alterations, which occur with advanced age, affect functional performance in both the lower and upper members, and consequently human motor functions. Objective measurements are important tools to help understand and characterize the dysfunctions and limitations that occur due to neuromuscular changes related to advancing age. Therefore, the objective of this study is to attest to the difference between groups of young and old individuals through manual movements and whether the combination of features can produce a linear correlation concerning the different age groups. METHODS This study counted on 99 participants, these were divided into 8 groups, which were grouped by age. The data collection was performed using inertial sensors (positioned on the back of the hand and on the back of the forearm). Firstly, the participants were divided into groups of young and elderly to verify if the groups could be distinguished through the features alone. Following this, the features were combined using the linear discriminant analysis (LDA), which gave rise to a singular feature called the LDA-value that aided in verifying the correlation between the different age ranges and the LDA-value. RESULTS The results demonstrated that 125 features are able to distinguish the difference between the groups of young and elderly individuals. The use of the LDA-value allows for the obtaining of a linear model of the changes that occur with aging in the performance of tasks in line with advancing age, the correlation obtained, using Pearson's coefficient, was 0.86. CONCLUSION When we compare only the young and elderly groups, the results indicate that there is a difference in the way tasks are performed between young and elderly individuals. When the 8 groups were analyzed, the linear correlation obtained was strong, with the LDA-value being effective in obtaining a linear correlation of the eight groups, demonstrating that although the features alone do not demonstrate gradual changes as a function of age, their combination established these changes.
Collapse
Affiliation(s)
- Veronica de Lima Gonçalves
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Caio Tonus Ribeiro
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Guilherme Lopes Cavalheiro
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Maria José Ferreira Zaruz
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Daniel Hilário da Silva
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Selma Terezinha Milagre
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Adriano de Oliveira Andrade
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil
| | - Adriano Alves Pereira
- Postgraduate Program in Electrical and Biomedical Engineering, Faculty of Electrical Engineering, Centre for Innovation and Technology Assessment in Health, Federal University of Uberlândia, Uberlândia, Brazil.
| |
Collapse
|
2
|
Ortega-Bastidas P, Gómez B, Aqueveque P, Luarte-Martínez S, Cano-de-la-Cuerda R. Instrumented Timed Up and Go Test (iTUG)-More Than Assessing Time to Predict Falls: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:3426. [PMID: 37050485 PMCID: PMC10098780 DOI: 10.3390/s23073426] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 06/19/2023]
Abstract
The Timed Up and Go (TUG) test is a widely used tool for assessing the risk of falls in older adults. However, to increase the test's predictive value, the instrumented Timed Up and Go (iTUG) test has been developed, incorporating different technological approaches. This systematic review aims to explore the evidence of the technological proposal for the segmentation and analysis of iTUG in elderlies with or without pathologies. A search was conducted in five major databases, following PRISMA guidelines. The review included 40 studies that met the eligibility criteria. The most used technology was inertial sensors (75% of the studies), with healthy elderlies (35%) and elderlies with Parkinson's disease (32.5%) being the most analyzed participants. In total, 97.5% of the studies applied automatic segmentation using rule-based algorithms. The iTUG test offers an economical and accessible alternative to increase the predictive value of TUG, identifying different variables, and can be used in clinical, community, and home settings.
Collapse
Affiliation(s)
- Paulina Ortega-Bastidas
- Health Sciences PhD Programme, International Doctoral School, Universidad Rey Juan Carlos, 28922 Madrid, Spain
- Kinesiology Department, Faculty of Medicine, Universidad de Concepción, Concepción, 151 Janequeo St., Concepcion 4030000, Chile
| | - Britam Gómez
- Biomedical Engineering, Faculty of Engineering, Universidad de Santiago de Chile, Libertador Bernardo O’Higgins Av., Santiago 9170022, Chile
| | - Pablo Aqueveque
- Department of Electrical Engineering, Faculty of Engineering, Universidad de Concepción, 219 Edmundo Larenas St., Concepción 4030000, Chile
| | - Soledad Luarte-Martínez
- Kinesiology Department, Faculty of Medicine, Universidad de Concepción, Concepción, 151 Janequeo St., Concepcion 4030000, Chile
| | - Roberto Cano-de-la-Cuerda
- Physiotherapy, Occupational Therapy, Rehabilitation and Physical Medicine Department, Universidad Rey Juan Carlos, 28922 Madrid, Spain
| |
Collapse
|
3
|
Detecting subtle mobility changes among older adults: the Quantitative Timed Up and Go test. Aging Clin Exp Res 2021; 33:2157-2164. [PMID: 33098079 DOI: 10.1007/s40520-020-01733-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 10/01/2020] [Indexed: 01/08/2023]
Abstract
BACKGROUND The Quantitative Timed Up and Go (QTUG) test uses wearable sensors, containing a triaxial accelerometer and an add-on triaxial gyroscope, to quantify performance during the TUG test with potential to capture more minor changes in mobility. AIMS To examine the responsiveness, minimum detectable change (MDC) and observed effect size of QTUG in a cohort of socially active adults aged 50 years and over participating in a structured community exercise program. METHODS 54 participants (91% females, mean age 63.6 ± 6.5 years) completed repeated QTUG testing under single- and dual-task conditions. Responsiveness of the QTUG was assessed by correlation of change in standard TUG with QTUG change (Pearson's correlation coefficient). MDC and effect sizes (standardized mean difference and Cohen's d) were also calculated for QTUG. RESULTS There was a strong positive correlation between change in the standard TUG and change in QTUG (single task r = 0.91, p < 0.001). MDC in QTUG was calculated as 0.77 (Sd, 1.39; ICC 0.96) seconds (single task) and 2.33 (Sd 2.18; ICC 0.85) seconds (dual task). Several QTUG parameters showed improvements in mean values with small effect sizes (sit -to-stand transition time d = 0.418; walk time d = 0.398; cadence d = 0.306, swing time d = 0.314; step time d = 0.479; gait velocity d = 0.365; time to reach turn d = 0.322) under single-task conditions and with a moderate effect size (d = 0.549) in time taken to turn under the dual-task condition. CONCLUSION Initial evidence of QTUG's responsiveness to change in mobility in active middle to older age adults has been demonstrated with small to moderate effect sizes observed in specific QTUG parameters.
Collapse
|
4
|
Fudickar S, Kiselev J, Stolle C, Frenken T, Steinhagen-Thiessen E, Wegel S, Hein A. Validation of a Laser Ranged Scanner-Based Detection of Spatio-Temporal Gait Parameters Using the aTUG Chair. SENSORS 2021; 21:s21041343. [PMID: 33668682 PMCID: PMC7918763 DOI: 10.3390/s21041343] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 12/15/2022]
Abstract
This article covers the suitability to measure gait-parameters via a Laser Range Scanner (LRS) that was placed below a chair during the walking phase of the Timed Up&Go Test in a cohort of 92 older adults (mean age 73.5). The results of our study demonstrated a high concordance of gait measurements using a LRS in comparison to the reference GAITRite walkway. Most of aTUG's gait parameters demonstrate a strong correlation coefficient with the GAITRite, indicating high measurement accuracy for the spatial gait parameters. Measurements of velocity had a correlation coefficient of 99%, which can be interpreted as an excellent measurement accuracy. Cadence showed a slightly lower correlation coefficient of 96%, which is still an exceptionally good result, while step length demonstrated a correlation coefficient of 98% per leg and stride length with an accuracy of 99% per leg. In addition to confirming the technical validation of the aTUG regarding its ability to measure gait parameters, we compared results from the GAITRite and the aTUG for several parameters (cadence, velocity, and step length) with results from the Berg Balance Scale (BBS) and the Activities-Specific Balance Confidence-(ABC)-Scale assessments. With confidence coefficients for BBS and velocity, cadence and step length ranging from 0.595 to 0.798 and for ABC ranging from 0.395 to 0.541, both scales demonstrated only a medium-sized correlation. Thus, we found an association of better walking ability (represented by the measured gait parameters) with better balance (BBC) and balance confidence (ABC) overall scores via linear regression. This results from the fact that the BBS incorporates both static and dynamic balance measures and thus, only partly reflects functional requirements for walking. For the ABC score, this effect was even more pronounced. As this is to our best knowledge the first evaluation of the association between gait parameters and these balance scores, we will further investigate this phenomenon and aim to integrate further measures into the aTUG to achieve an increased sensitivity for balance ability.
Collapse
Affiliation(s)
- Sebastian Fudickar
- Assistance Systems and Medical Device Technology, Carl von Ossietzky University Oldenburg, 26129 Oldenburg, Germany; (C.S.); (A.H.)
- Correspondence:
| | - Jörn Kiselev
- Geriatrics Research Group, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany; (J.K.); (E.S.-T.); (S.W.)
- Department of Anesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany
| | - Christian Stolle
- Assistance Systems and Medical Device Technology, Carl von Ossietzky University Oldenburg, 26129 Oldenburg, Germany; (C.S.); (A.H.)
| | - Thomas Frenken
- IT Services Thomas Frenken, Loyerweg 62a, 26180 Rastede, Germany;
| | - Elisabeth Steinhagen-Thiessen
- Geriatrics Research Group, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany; (J.K.); (E.S.-T.); (S.W.)
- Divison of Lipid Metabolism of the Department of Endocrinology and Metabolic Medicine, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany
| | - Sandra Wegel
- Geriatrics Research Group, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany; (J.K.); (E.S.-T.); (S.W.)
- Department of Surgery (CCM, CVK), Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, D-10117 Berlin, Germany
| | - Andreas Hein
- Assistance Systems and Medical Device Technology, Carl von Ossietzky University Oldenburg, 26129 Oldenburg, Germany; (C.S.); (A.H.)
| |
Collapse
|
5
|
|
6
|
Viteckova S, Cejka V, Dusek P, Krupicka R, Kutilek P, Szabo Z, Růžička E. Extended Timed Up & Go test: Is walking forward and returning back to the chair equivalent gait? J Biomech 2019; 89:110-114. [PMID: 30982536 DOI: 10.1016/j.jbiomech.2019.04.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 03/22/2019] [Accepted: 04/02/2019] [Indexed: 10/27/2022]
Abstract
The Timed Up & Go test (TUG) is functional test and is a part of routine clinical examinations. The instrumented Timed Up & Go test enables its segmentation to sub-tasks: sit-to-stand, walking forward, turning, walking back, stand-to-sit, and consequently the computation of task-specific parameters and sub-tasks separately. However, there are no data on whether walking forward parameters differ from the walking back parameters. This study tested the differences between walking forward and walking back in the TUG extended to 10 m for 17 spatio-temporal gait parameters. All parameters were obtained from a GAITRite® pressure sensitive walkway (CIR Systems, Inc.). The differences were assessed for healthy controls and Parkinson's disease (PD) patients. None of investigated parameters exhibited a difference between both gait subtasks for healthy subjects group. Five parameters of interest, namely velocity, step length, stride length, stride velocity, and the proportion of the double support phase with respect to gait cycle duration, showed a statistically significant difference between gait for walking forward and walking back in PD patients. Therefore, we recommend a separate assessment for walking forward and walking back rather than averaging both gaits together.
Collapse
Affiliation(s)
- Slavka Viteckova
- Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic.
| | - Vaclav Cejka
- Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic.
| | - Petr Dusek
- Department of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.
| | - Radim Krupicka
- Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic.
| | - Patrik Kutilek
- Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic.
| | - Zoltan Szabo
- Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic.
| | - Evžen Růžička
- Department of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic.
| |
Collapse
|
7
|
Lebel K, Nguyen H, Duval C, Plamondon R, Boissy P. Capturing the Cranio-Caudal Signature of a Turn with Inertial Measurement Systems: Methods, Parameters Robustness and Reliability. Front Bioeng Biotechnol 2017; 5:51. [PMID: 28879179 PMCID: PMC5572419 DOI: 10.3389/fbioe.2017.00051] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 08/04/2017] [Indexed: 11/30/2022] Open
Abstract
Background Turning is a challenging mobility task requiring coordination and postural stability. Optimal turning involves a cranio-caudal sequence (i.e., the head initiates the motion, followed by the trunk and the pelvis), which has been shown to be altered in patients with neurodegenerative diseases, such as Parkinson’s disease as well as in fallers and frails. Previous studies have suggested that the cranio-caudal sequence exhibits a specific signature corresponding to the adopted turn strategy. Currently, the assessment of cranio-caudal sequence is limited to biomechanical labs which use camera-based systems; however, there is a growing trend to assess human kinematics with wearable sensors, such as attitude and heading reference systems (AHRS), which enable recording of raw inertial signals (acceleration and angular velocity) from which the orientation of the platform is estimated. In order to enhance the comprehension of complex processes, such as turning, signal modeling can be performed. Aim The current study investigates the use of a kinematic-based model, the sigma-lognormal model, to characterize the turn cranio-caudal signature as assessed with AHRS. Methods Sixteen asymptomatic adults (mean age = 69.1 ± 7.5 years old) performed repeated 10-m Timed-Up-and-Go (TUG) with 180° turns, at varying speed. Head and trunk kinematics were assessed with AHRS positioned on each segments. Relative orientation of the head to the trunk was then computed for each trial and relative angular velocity profile was derived for the turn phase. Peak relative angle (variable) and relative velocity profiles modeled using a sigma-lognormal approach (variables: Neuromuscular command amplitudes and timing parameters) were used to extract and characterize the cranio-caudal signature of each individual during the turn phase. Results The methodology has shown good ability to reconstruct the cranio-caudal signature (signal-to-noise median of 17.7). All variables were robust to speed variations (p > 0.124). Peak relative angle and commanded amplitudes demonstrated moderate to strong reliability (ICC between 0.640 and 0.808). Conclusion The cranio-caudal signature assessed with the sigma-lognormal model appears to be a promising avenue to assess the efficiency of turns.
Collapse
Affiliation(s)
- Karina Lebel
- Faculty of Medicine and Health Sciences, Orthopedic Service, Department of Surgery, Université de Sherbrooke, Sherbrooke, QC, Canada.,Research Centre on Aging, Sherbrooke, QC, Canada
| | - Hung Nguyen
- Département des Sciences de l'activité Physique, Université du Québec à Montréal, Montreal, QC, Canada.,Centre de Recherche Institut Universitaire de Gériatrie de Montréal, Montreal, QC, Canada
| | - Christian Duval
- Département des Sciences de l'activité Physique, Université du Québec à Montréal, Montreal, QC, Canada.,Centre de Recherche Institut Universitaire de Gériatrie de Montréal, Montreal, QC, Canada
| | - Réjean Plamondon
- Laboratoire Scribens, Département de génie Électrique, École Polytechnique de Montréal, Montréal, QC, Canada
| | - Patrick Boissy
- Faculty of Medicine and Health Sciences, Orthopedic Service, Department of Surgery, Université de Sherbrooke, Sherbrooke, QC, Canada.,Research Centre on Aging, Sherbrooke, QC, Canada
| |
Collapse
|
8
|
Tedesco S, Barton J, O'Flynn B. A Review of Activity Trackers for Senior Citizens: Research Perspectives, Commercial Landscape and the Role of the Insurance Industry. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1277. [PMID: 28587188 PMCID: PMC5492436 DOI: 10.3390/s17061277] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 05/31/2017] [Accepted: 05/31/2017] [Indexed: 12/18/2022]
Abstract
The objective assessment of physical activity levels through wearable inertial-based motion detectors for the automatic, continuous and long-term monitoring of people in free-living environments is a well-known research area in the literature. However, their application to older adults can present particular constraints. This paper reviews the adoption of wearable devices in senior citizens by describing various researches for monitoring physical activity indicators, such as energy expenditure, posture transitions, activity classification, fall detection and prediction, gait and balance analysis, also by adopting consumer-grade fitness trackers with the associated limitations regarding acceptability. This review also describes and compares existing commercial products encompassing activity trackers tailored for older adults, thus providing a comprehensive outlook of the status of commercially available motion tracking systems. Finally, the impact of wearable devices on life and health insurance companies, with a description of the potential benefits for the industry and the wearables market, was analyzed as an example of the potential emerging market drivers for such technology in the future.
Collapse
Affiliation(s)
- Salvatore Tedesco
- Tyndall National Institute, University College Cork/Lee Maltings, Prospect Row, Cork T12R5CP, Ireland.
| | - John Barton
- Tyndall National Institute, University College Cork/Lee Maltings, Prospect Row, Cork T12R5CP, Ireland.
| | - Brendan O'Flynn
- Tyndall National Institute, University College Cork/Lee Maltings, Prospect Row, Cork T12R5CP, Ireland.
| |
Collapse
|
9
|
Similä H, Immonen M, Ermes M. Accelerometry-based assessment and detection of early signs of balance deficits. Comput Biol Med 2017; 85:25-32. [PMID: 28432935 DOI: 10.1016/j.compbiomed.2017.04.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 04/12/2017] [Accepted: 04/12/2017] [Indexed: 11/28/2022]
Abstract
Falls are the cause for more than half of the injury-related hospitalizations among older people. Accurate assessment of individuals' fall risk could enable targeted interventions to reduce the risk. This paper presents a novel method for using wearable accelerometers to detect early signs of deficits in balance from gait. Gait acceleration data were analyzed from 35 healthy female participants (73.86±5.40 years). The data were collected with waist-mounted accelerometer and the participants performed three supervised balance tests: Berg Balance Scale (BBS), Timed-Up-and-Go (TUG) and 4m walk. The follow-up tests with the same protocol were performed after one year. Altogether 43 features were extracted from the accelerometer signals. Sequential forward floating selection and ten-fold cross-validation were applied to determine models for 1) estimating the outcomes of BBS, TUG and 4m walk tests and 2) predicting decline in balance during one-year follow-up indicated as decline in BBS total score and one leg stance. Normalized root-mean-square errors (RMSE) of the assessment scale result estimates were 0.28 for BBS score, 0.18 for TUG time, and 0.22 for 4m walk test. Area under curve (AUC) was 0.78 for predicting decline in BBS total score and 0.82 for one leg stance, respectively. The results suggest that the gait features can be used to estimate the result of a clinical balance assessment scale and predict decline in balance. A simple walk test with wearable monitoring could be applicable as an initial screening tool to identify people with early signs of balance deficits.
Collapse
Affiliation(s)
- Heidi Similä
- VTT Technical Research Centre of Finland Ltd, Kaitoväylä 1, P.O.Box 1100, FI-90571 Oulu, Finland.
| | - Milla Immonen
- VTT Technical Research Centre of Finland Ltd, Kaitoväylä 1, P.O.Box 1100, FI-90571 Oulu, Finland.
| | - Miikka Ermes
- VTT Technical Research Centre of Finland Ltd, Tekniikankatu 1, P.O.Box 1300, 33101 Tampere, Finland.
| |
Collapse
|
10
|
Use of Wearable Inertial Sensor in the Assessment of Timed-Up-and-Go Test: Influence of Device Placement on Temporal Variable Estimation. LECTURE NOTES OF THE INSTITUTE FOR COMPUTER SCIENCES, SOCIAL INFORMATICS AND TELECOMMUNICATIONS ENGINEERING 2017. [DOI: 10.1007/978-3-319-58877-3_40] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
11
|
Vervoort D, Vuillerme N, Kosse N, Hortobágyi T, Lamoth CJC. Multivariate Analyses and Classification of Inertial Sensor Data to Identify Aging Effects on the Timed-Up-and-Go Test. PLoS One 2016; 11:e0155984. [PMID: 27271994 PMCID: PMC4894562 DOI: 10.1371/journal.pone.0155984] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Accepted: 05/06/2016] [Indexed: 11/17/2022] Open
Abstract
Many tests can crudely quantify age-related mobility decrease but instrumented versions of mobility tests could increase their specificity and sensitivity. The Timed-up-and-Go (TUG) test includes several elements that people use in daily life. The test has different transition phases: rise from a chair, walk, 180° turn, walk back, turn, and sit-down on a chair. For this reason the TUG is an often used test to evaluate in a standardized way possible decline in balance and walking ability due to age and or pathology. Using inertial sensors, qualitative information about the performance of the sub-phases can provide more specific information about a decline in balance and walking ability. The first aim of our study was to identify variables extracted from the instrumented timed-up-and-go (iTUG) that most effectively distinguished performance differences across age (age 18-75). Second, we determined the discriminative ability of those identified variables to classify a younger (age 18-45) and older age group (age 46-75). From healthy adults (n = 59), trunk accelerations and angular velocities were recorded during iTUG performance. iTUG phases were detected with wavelet-analysis. Using a Partial Least Square (PLS) model, from the 72-iTUG variables calculated across phases, those that explained most of the covariance between variables and age were extracted. Subsequently, a PLS-discriminant analysis (DA) assessed classification power of the identified iTUG variables to discriminate the age groups. 27 variables, related to turning, walking and the stand-to-sit movement explained 71% of the variation in age. The PLS-DA with these 27 variables showed a sensitivity and specificity of 90% and 85%. Based on this model, the iTUG can accurately distinguish young and older adults. Such data can serve as a reference for pathological aging with respect to a widely used mobility test. Mobility tests like the TUG supplemented with smart technology could be used in clinical practice.
Collapse
Affiliation(s)
- Danique Vervoort
- University of Groningen, University Medical Center Groningen, Center for Human Movement Sciences, Groningen, The Netherlands
| | - Nicolas Vuillerme
- University Grenoble-Alpes, AGEIS, La Tronche, France.,Institut Universitaire de France, Paris, France
| | - Nienke Kosse
- University of Groningen, University Medical Center Groningen, Center for Human Movement Sciences, Groningen, The Netherlands.,University Grenoble-Alpes, AGEIS, La Tronche, France
| | - Tibor Hortobágyi
- University of Groningen, University Medical Center Groningen, Center for Human Movement Sciences, Groningen, The Netherlands
| | - Claudine J C Lamoth
- University of Groningen, University Medical Center Groningen, Center for Human Movement Sciences, Groningen, The Netherlands
| |
Collapse
|