1
|
Rockette-Wagner B, Aggarwal R. A review of the evidence for the utility of physical activity monitor use in patients with idiopathic inflammatory myopathies. Rheumatology (Oxford) 2024; 63:1815-1824. [PMID: 38243707 DOI: 10.1093/rheumatology/keae004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/13/2023] [Accepted: 12/13/2023] [Indexed: 01/21/2024] Open
Abstract
Few proven therapies exist for patients with idiopathic inflammatory myopathies (IIMs), partly due to the lack of reliable and valid outcome measures for assessing treatment responses. The current core set measures developed by the International Myositis Assessment and Clinical Studies group were developed to standardize assessments of disease activity and treatment effect. None of the current measures address functional improvement in muscle weakness. Therefore, supplemental measures to more objectively assess physical activity levels and fatiguability in free-living settings are needed to assess disease activity more comprehensively. Validated physical activity monitors (PAMs) have the potential to serve as an objective functional outcome measure in clinical trials and observational studies. This review examines the current evidence for the use of body-worn PAMs in clinical settings with IIM patients. A practical overview of methods for PAM use in clinical patient populations (including measurement details and data processing) that focuses on IIM patients is also presented.
Collapse
Affiliation(s)
- Bonny Rockette-Wagner
- Department of Epidemiology, University of Pittsburgh School of Public Health, Pittsburgh, PA, USA
| | - Rohit Aggarwal
- Division of Rheumatology and Clinical Immunology, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| |
Collapse
|
2
|
Strick JA, Farris RJ, Sawicki JT. A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information. J Biomech Eng 2024; 146:044502. [PMID: 38183222 DOI: 10.1115/1.4064435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 12/27/2023] [Indexed: 01/07/2024]
Abstract
This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.
Collapse
Affiliation(s)
- Jacob A Strick
- Center for Rotating Machinery Dynamics and Control (RoMaDyC), Washkewicz College of Engineering, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115
| | - Ryan J Farris
- Department of Engineering, Messiah University, One University Avenue, Mechanicsburg, PA 17055
| | - Jerzy T Sawicki
- Center for Rotating Machinery Dynamics and Control (RoMaDyC), Washkewicz College of Engineering, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115
| |
Collapse
|
3
|
Yang S, Koo B, Lee S, Jang DJ, Shin H, Choi HJ, Kim Y. Determination of Gait Events and Temporal Gait Parameters for Persons with a Knee-Ankle-Foot Orthosis. SENSORS (BASEL, SWITZERLAND) 2024; 24:964. [PMID: 38339681 PMCID: PMC10857118 DOI: 10.3390/s24030964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/22/2024] [Accepted: 01/30/2024] [Indexed: 02/12/2024]
Abstract
Gait event detection is essential for controlling an orthosis and assessing the patient's gait. In this study, patients wearing an electromechanical (EM) knee-ankle-foot orthosis (KAFO) with a single IMU embedded in the thigh were subjected to gait event detection. The algorithm detected four essential gait events (initial contact (IC), toe off (TO), opposite initial contact (OIC), and opposite toe off (OTO)) and determined important temporal gait parameters such as stance/swing time, symmetry, and single/double limb support. These gait events were evaluated through gait experiments using four force plates on healthy adults and a hemiplegic patient who wore a one-way clutch KAFO and a pneumatic cylinder KAFO. Results showed that the smallest error in gait event detection was found at IC, and the largest error rate was observed at opposite toe off (OTO) with an error rate of -2.8 ± 1.5% in the patient group. Errors in OTO detection resulted in the largest error in determining the single limb support of the patient with an error of 5.0 ± 1.5%. The present study would be beneficial for the real-time continuous monitoring of gait events and temporal gait parameters for persons with an EM KAFO.
Collapse
Affiliation(s)
- Sumin Yang
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea; (S.Y.); (B.K.); (S.L.)
| | - Bummo Koo
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea; (S.Y.); (B.K.); (S.L.)
| | - Seunghee Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea; (S.Y.); (B.K.); (S.L.)
| | - Dae-Jin Jang
- Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea; (D.-J.J.); (H.S.); (H.-J.C.)
| | - Hyunjun Shin
- Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea; (D.-J.J.); (H.S.); (H.-J.C.)
| | - Hyuk-Jae Choi
- Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea; (D.-J.J.); (H.S.); (H.-J.C.)
| | - Youngho Kim
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea; (S.Y.); (B.K.); (S.L.)
| |
Collapse
|
4
|
Jamsrandorj A, Jung D, Kumar KS, Arshad MZ, Lim H, Kim J, Mun KR. View-independent gait events detection using CNN-transformer hybrid network. J Biomed Inform 2023; 147:104524. [PMID: 37838288 DOI: 10.1016/j.jbi.2023.104524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 09/11/2023] [Accepted: 10/10/2023] [Indexed: 10/16/2023]
Abstract
Accurate gait detection is crucial in utilizing the ample health information embedded in it. Vision-based approaches for gait detection have emerged as an alternative to the exacting sensor-based approaches, but their application has been rather limited due to complicated feature engineering processes and heavy reliance on lateral views. Thus, this study aimed to find a simple vision-based approach that is view-independent and accurate. A total of 22 participants performed six different actions representing standard and peculiar gaits, and the videos acquired from these actions were used as the input of the deep learning networks. Four networks, including a 2D convolutional neural network and an attention-based deep learning network, were trained with standard gaits, and their detection performance for both standard and peculiar gaits was assessed using measures including F1-scores. While all networks achieved remarkable detection performance, the CNN-Transformer network achieved the best performance for both standard and peculiar gaits. Little deviation by the speed of actions or view angles was found. The study is expected to contribute to the wider application of vision-based approaches in gait detection and gait-based health monitoring both at home and in clinical settings.
Collapse
Affiliation(s)
- Ankhzaya Jamsrandorj
- Department of Human Computer Interface & Robotics Engineering, KIST School, University of Science & Technology, Seoul, Republic of Korea; Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Dawoon Jung
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Konki Sravan Kumar
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Muhammad Zeeshan Arshad
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Hwasup Lim
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Jinwook Kim
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea.
| | - Kyung-Ryoul Mun
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, Republic of Korea; KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Hafer JF, Mihy JA, Hunt A, Zernicke RF, Johnson RT. Lower Extremity Inverse Kinematics Results Differ Between Inertial Measurement Unit- and Marker-Derived Gait Data. J Appl Biomech 2023; 39:133-142. [PMID: 37024103 DOI: 10.1123/jab.2022-0194] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 11/30/2022] [Accepted: 02/07/2023] [Indexed: 04/08/2023]
Abstract
In-lab, marker-based gait analyses may not represent real-world gait. Real-world gait analyses may be feasible using inertial measurement units (IMUs) in combination with open-source data processing pipelines (OpenSense). Before using OpenSense to study real-world gait, we must determine whether these methods estimate joint kinematics similarly to traditional marker-based motion capture (MoCap) and differentiate groups with clinically different gait mechanics. Healthy young and older adults and older adults with knee osteoarthritis completed this study. We captured MoCap and IMU data during overground walking at 2 speeds. MoCap and IMU kinematics were computed with OpenSim workflows. We tested whether sagittal kinematics differed between MoCap and IMU, whether tools detected between-group differences similarly, and whether kinematics differed between tools by speed. MoCap showed more anterior pelvic tilt (0%-100% stride) and joint flexion than IMU (hip: 0%-38% and 61%-100% stride; knee: 0%-38%, 58%-89%, and 95%-99% stride; and ankle: 6%-99% stride). There were no significant tool-by-group interactions. We found significant tool-by-speed interactions for all angles. While MoCap- and IMU-derived kinematics differed, the lack of tool-by-group interactions suggests consistent tracking across clinical cohorts. Results of the current study suggest that IMU-derived kinematics with OpenSense may enable reliable evaluation of gait in real-world settings.
Collapse
Affiliation(s)
- Jocelyn F Hafer
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE,USA
- School of Kinesiology, University of Michigan, Ann Arbor, MI,USA
| | - Julien A Mihy
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE,USA
| | - Andrew Hunt
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE,USA
| | - Ronald F Zernicke
- School of Kinesiology, University of Michigan, Ann Arbor, MI,USA
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI,USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI,USA
| | - Russell T Johnson
- Division of Biokinesiology and Physical Therapy, University of Southern California, Los Angeles, CA,USA
| |
Collapse
|
6
|
Bach MM, Dominici N, Daffertshofer A. Predicting vertical ground reaction forces from 3D accelerometry using reservoir computers leads to accurate gait event detection. Front Sports Act Living 2022; 4:1037438. [PMID: 36385782 PMCID: PMC9644164 DOI: 10.3389/fspor.2022.1037438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 10/04/2022] [Indexed: 11/06/2022] Open
Abstract
Accelerometers are low-cost measurement devices that can readily be used outside the lab. However, determining isolated gait events from accelerometer signals, especially foot-off events during running, is an open problem. We outline a two-step approach where machine learning serves to predict vertical ground reaction forces from accelerometer signals, followed by force-based event detection. We collected shank accelerometer signals and ground reaction forces from 21 adults during comfortable walking and running on an instrumented treadmill. We trained one common reservoir computer using segmented data using both walking and running data. Despite being trained on just a small number of strides, this reservoir computer predicted vertical ground reaction forces in continuous gait with high quality. The subsequent foot contact and foot off event detection proved highly accurate when compared to the gold standard based on co-registered ground reaction forces. Our proof-of-concept illustrates the capacity of combining accelerometry with machine learning for detecting isolated gait events irrespective of mode of locomotion.
Collapse
|
7
|
Meyer BM, Tulipani LJ, Gurchiek RD, Allen DA, Solomon AJ, Cheney N, McGinnis RS. Open-source dataset reveals relationship between walking bout duration and fall risk classification performance in persons with multiple sclerosis. PLOS DIGITAL HEALTH 2022; 1:e0000120. [PMID: 36812538 PMCID: PMC9931255 DOI: 10.1371/journal.pdig.0000120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 09/02/2022] [Indexed: 11/06/2022]
Abstract
Falls are frequent and associated with morbidity in persons with multiple sclerosis (PwMS). Symptoms of MS fluctuate, and standard biannual clinical visits cannot capture these fluctuations. Remote monitoring techniques that leverage wearable sensors have recently emerged as an approach sensitive to disease variability. Previous research has shown that fall risk can be identified from walking data collected by wearable sensors in controlled laboratory conditions however this data may not be generalizable to variable home environments. To investigate fall risk and daily activity performance from remote data, we introduce a new open-source dataset featuring data collected from 38 PwMS, 21 of whom are identified as fallers and 17 as non-fallers based on their six-month fall history. This dataset contains inertial-measurement-unit data from eleven body locations collected in the laboratory, patient-reported surveys and neurological assessments, and two days of free-living sensor data from the chest and right thigh. Six-month (n = 28) and one-year repeat assessment (n = 15) data are also available for some patients. To demonstrate the utility of these data, we explore the use of free-living walking bouts for characterizing fall risk in PwMS, compare these data to those collected in controlled environments, and examine the impact of bout duration on gait parameters and fall risk estimates. Both gait parameters and fall risk classification performance were found to change with bout duration. Deep learning models outperformed feature-based models using home data; the best performance was observed with all bouts for deep-learning and short bouts for feature-based models when evaluating performance on individual bouts. Overall, short duration free-living walking bouts were found to be the least similar to laboratory walking, longer duration free-living walking bouts provided more significant differences between fallers and non-fallers, and an aggregation of all free-living walking bouts yields the best performance in fall risk classification.
Collapse
Affiliation(s)
- Brett M. Meyer
- Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, Vermont, United States of America
- Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, Massachusetts, United States of America
| | - Lindsey J. Tulipani
- Department of Bioengineering, Stanford University, Stanford, California, United States of America
| | - Reed D. Gurchiek
- Department of Neurological Sciences, Larner College of Medicine at the University of Vermont, Burlington, Vermont, United States of America
| | - Dakota A. Allen
- Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, Vermont, United States of America
| | - Andrew J. Solomon
- Department of Computer Science, University of Vermont, Burlington, Vermont, United States of America
| | - Nick Cheney
- Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, Massachusetts, United States of America
| | - Ryan S. McGinnis
- Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, Vermont, United States of America
- * E-mail:
| |
Collapse
|
8
|
Kim YK, Visscher RMS, Viehweger E, Singh NB, Taylor WR, Vogl F. A deep-learning approach for automatically detecting gait-events based on foot-marker kinematics in children with cerebral palsy-Which markers work best for which gait patterns? PLoS One 2022; 17:e0275878. [PMID: 36227847 PMCID: PMC9562216 DOI: 10.1371/journal.pone.0275878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 09/25/2022] [Indexed: 11/06/2022] Open
Abstract
Neuromotor pathologies often cause motor deficits and deviations from typical locomotion, reducing the quality of life. Clinical gait analysis is used to effectively classify these motor deficits to gain deeper insights into resulting walking behaviours. To allow the ensemble averaging of spatio-temporal metrics across individuals during walking, gait events, such as initial contact (IC) or toe-off (TO), are extracted through either manual annotation based on video data, or through force thresholds using force plates. This study developed a deep-learning long short-term memory (LSTM) approach to detect IC and TO automatically based on foot-marker kinematics of 363 cerebral palsy subjects (age: 11.8 ± 3.2). These foot-marker kinematics, including 3D positions and velocities of the markers located on the hallux (HLX), calcaneus (HEE), distal second metatarsal (TOE), and proximal fifth metatarsal (PMT5), were extracted retrospectively from standard barefoot gait analysis sessions. Different input combinations of these four foot-markers were evaluated across three gait subgroups (IC with the heel, midfoot, or forefoot). For the overall group, our approach detected 89.7% of ICs within 16ms of the true event with a 18.5% false alarm rate. For TOs, only 71.6% of events were detected with a 33.8% false alarm rate. While the TOE|HEE marker combination performed well across all subgroups for IC detection, optimal performance for TO detection required different input markers per subgroup with performance differences of 5-10%. Thus, deep-learning LSTM based detection of IC events using the TOE|HEE markers offers an automated alternative to avoid operator-dependent and laborious manual annotation, as well as the limited step coverage and inability to measure assisted walking for force plate-based detection of IC events.
Collapse
Affiliation(s)
- Yong Kuk Kim
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- * E-mail:
| | - Rosa M. S. Visscher
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Elke Viehweger
- Laboratory for Movement Analysis, Department of Orthopedics, University Children’s Hospital Basel, Basel, Switzerland
| | - Navrag B. Singh
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - William R. Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Florian Vogl
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
9
|
Meyer BM, Depetrillo P, Franco J, Donahue N, Fox SR, O’Leary A, Loftness BC, Gurchiek RD, Buckley M, Solomon AJ, Ng SK, Cheney N, Ceruolo M, McGinnis RS. How Much Data Is Enough? A Reliable Methodology to Examine Long-Term Wearable Data Acquisition in Gait and Postural Sway. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22186982. [PMID: 36146348 PMCID: PMC9503816 DOI: 10.3390/s22186982] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/10/2022] [Accepted: 09/13/2022] [Indexed: 06/12/2023]
Abstract
Wearable sensors facilitate the evaluation of gait and balance impairment in the free-living environment, often with observation periods spanning weeks, months, and even years. Data supporting the minimal duration of sensor wear, which is necessary to capture representative variability in impairment measures, are needed to balance patient burden, data quality, and study cost. Prior investigations have examined the duration required for resolving a variety of movement variables (e.g., gait speed, sit-to-stand tests), but these studies use differing methodologies and have only examined a small subset of potential measures of gait and balance impairment. Notably, postural sway measures have not yet been considered in these analyses. Here, we propose a three-level framework for examining this problem. Difference testing and intra-class correlations (ICC) are used to examine the agreement in features computed from potential wear durations (levels one and two). The association between features and established patient reported outcomes at each wear duration is also considered (level three) for determining the necessary wear duration. Utilizing wearable accelerometer data continuously collected from 22 persons with multiple sclerosis (PwMS) for 6 weeks, this framework suggests that 2 to 3 days of monitoring may be sufficient to capture most of the variability in gait and sway; however, longer periods (e.g., 3 to 6 days) may be needed to establish strong correlations to patient-reported clinical measures. Regression analysis indicates that the required wear duration depends on both the observation frequency and variability of the measure being considered. This approach provides a framework for evaluating wear duration as one aspect of the comprehensive assessment, which is necessary to ensure that wearable sensor-based methods for capturing gait and balance impairment in the free-living environment are fit for purpose.
Collapse
Affiliation(s)
- Brett M. Meyer
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Paolo Depetrillo
- Medidata Solutions, A Dassault Systèmes Company, New York, NY 10014, USA
| | - Jaime Franco
- Medidata Solutions, A Dassault Systèmes Company, New York, NY 10014, USA
| | - Nicole Donahue
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Samantha R. Fox
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Aisling O’Leary
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Bryn C. Loftness
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Reed D. Gurchiek
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Maura Buckley
- Medidata Solutions, A Dassault Systèmes Company, New York, NY 10014, USA
| | - Andrew J. Solomon
- Department of Neurological Sciences, University of Vermont, Burlington, VT 05405, USA
| | - Sau Kuen Ng
- Medidata Solutions, A Dassault Systèmes Company, New York, NY 10014, USA
| | - Nick Cheney
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| | - Melissa Ceruolo
- Medidata Solutions, A Dassault Systèmes Company, New York, NY 10014, USA
| | - Ryan S. McGinnis
- M-Sense Research Group, University of Vermont, Burlington, VT 05405, USA
| |
Collapse
|
10
|
Foot-to-Ground Phases Detection: A Comparison of Data Representation Formatting Methods with Respect to Adaption of Deep Learning Architectures. COMPUTERS 2022. [DOI: 10.3390/computers11050058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Identifying the foot stance and foot swing phases, also known as foot-to-ground (FTG) detection, is a branch of Human Activity Recognition (HAR). Our study aims to detect two main phases of the gait (i.e., foot-off and foot-contact) corresponding to the moments when each foot is in contact with the ground or not. This will allow the medical professionals to characterize and identify the different phases of the human gait and their respective patterns. This detection process is paramount for extracting gait features (e.g., step width, stride width, gait speed, cadence, etc.) used by medical experts to highlight gait anomalies, stance issues, or any other walking irregularities. It will be used to assist health practitioners with patient monitoring, in addition to developing a full pipeline for FTG detection that would help compute gait indicators. In this paper, a comparison of different training configurations, including model architectures, data formatting, and pre-processing, was conducted to select the parameters leading to the highest detection accuracy. This binary classification provides a label for each timestamp informing whether the foot is in contact with the ground or not. Models such as CNN, LSTM, and ConvLSTM were the best fits for this study. Yet, we did not exclude DNNs and Machine Learning models, such as Random Forest and XGBoost from our work in order to have a wide range of possible comparisons. As a result of our experiments, which included 27 senior participants who had a stroke in the past wearing IMU sensors on their ankles, the ConvLSTM model achieved a high accuracy of 97.01% for raw windowed data with a size of 3 frames per window, and each window was formatted to have two superimposed channels (accelerometer and gyroscope channels). The model was trained to have the best detection without any knowledge of the participants’ personal information including age, gender, health condition, the type of activity, or the used foot. In other words, the model’s input data only originated from IMU sensors. Overall, in terms of FTG detection, the combination of the ConvLSTM model and the data representation had an important impact in outperforming other start-of-the-art configurations; in addition, the compromise between the model’s complexity and its accuracy is a major asset for deploying this model and developing real-time solutions.
Collapse
|
11
|
Wristbands Containing Accelerometers for Objective Arm Swing Analysis in Patients with Parkinson's Disease. SENSORS 2020; 20:s20154339. [PMID: 32759667 PMCID: PMC7436032 DOI: 10.3390/s20154339] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 07/29/2020] [Accepted: 07/29/2020] [Indexed: 11/24/2022]
Abstract
In patients with Parkinson’s disease (PD), arm swing changes are common, even in the early stages, and these changes are usually evaluated subjectively by an expert. In this article, hypothesize that arm swing changes can be detected using a low-cost, cloud-based, wearable, sensor system that incorporates triaxial accelerometers. The aim of this work is to develop a low-cost, assistive diagnostic tool for use in quantifying the arm swing kinematics of patients with PD. Ten patients with PD and 11 age-matched, healthy subjects are included in the study. Four feature extraction techniques were applied: (i) Asymmetry estimation based on root mean square (RMS) differences between arm movements; (ii) posterior–anterior phase and cycle regularity through autocorrelation; (iii) tremor energy, established using Fourier transform analysis; and (iv) signal complexity through the fractal dimension by wavelet analysis. The PD group showed significant (p < 0.05) reductions in arm swing RMS values, higher arm swing asymmetry, higher anterior–posterior phase regularities, greater “high energy frequency” signals, and higher complexity in their XZ plane signals. Therefore, the novel, portable system provides a reliable means to support clinical practice in PD assessment.
Collapse
|