1
|
Jacobson BC, Anderson JC, Burke CA, Dominitz JA, Gross SA, May FP, Patel SG, Shaukat A, Robertson DJ. Optimizing bowel preparation quality for colonoscopy: consensus recommendations by the US Multi-Society Task Force on Colorectal Cancer. Gastrointest Endosc 2025; 101:702-732. [PMID: 40047767 DOI: 10.1016/j.gie.2025.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Indexed: 04/07/2025]
Abstract
This document is an update to the 2014 recommendations for optimizing the adequacy of bowel cleansing for colonoscopy from the US Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology, the American Gastroenterological Association, and the American Society for Gastrointestinal Endoscopy. The US Multi-Society Task Force developed consensus statements and key clinical concepts addressing important aspects of bowel preparation for colonoscopy. The majority of consensus statements focus on individuals at average risk for inadequate bowel preparation. However, statements addressing individuals at risk for inadequate bowel preparation quality are also provided. The quality of a bowel preparation is defined as adequate when standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy. We recommend the use of a split-dose bowel preparation regimen and suggest that a 2 L regimen may be sufficient. A same-day regimen is recommended as an acceptable alternative for individuals undergoing afternoon colonoscopy, but we suggest that a same-day regimen is an inferior alternative for individuals undergoing morning colonoscopy. We recommend limiting dietary restrictions to the day before a colonoscopy, relying on either clear liquids or low-fiber/low-residue diets for the early and midday meals. We suggest the adjunctive use of oral simethicone for bowel preparation before colonoscopy. Routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit is also recommended, with a target of >90% for both rates.
Collapse
Affiliation(s)
- Brian C Jacobson
- Department of Medicine, Division of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA; Harvard Medical School, Boston, Massachusetts, USA
| | - Joseph C Anderson
- VA Medical Center, White River Junction, Vermont, USA; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA; University of Connecticut School of Medicine, Farmington, Connecticut, USA
| | - Carol A Burke
- Department of Gastroenterology, Hepatology and Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jason A Dominitz
- Gastroenterology Section, VA Puget Sound Health Care System, Seattle, Washington, USA; Department of Medicine, Division of Gastroenterology, University of Washington, Seattle, Washington, USA
| | | | - Folasade P May
- Department of Medicine, Division of Gastroenterology, Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California, USA; Vatche and Tamar Manoukian Division of Digestive Diseases and Jonsson Comprehensive Cancer Center, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Swati G Patel
- University of Colorado Anschutz Medical Center, Aurora, Colorado, USA; Rocky Mountain Regional Veterans Affairs Medical Center, Aurora, Colorado, USA
| | - Aasma Shaukat
- GI Section, Minneapolis VA Medical Center and University of Minnesota, Minneapolis, Minnesota, USA
| | - Douglas J Robertson
- VA Medical Center, White River Junction, Vermont, USA; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA
| |
Collapse
|
2
|
Jacobson BC, Anderson JC, Burke CA, Dominitz JA, Gross SA, May FP, Patel SG, Shaukat A, Robertson DJ. Optimizing Bowel Preparation Quality for Colonoscopy: Consensus Recommendations by the US Multi-Society Task Force on Colorectal Cancer. Am J Gastroenterol 2025; 120:738-764. [PMID: 40035345 DOI: 10.14309/ajg.0000000000003287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Indexed: 03/05/2025]
Abstract
This document is an update to the 2014 recommendations for optimizing the adequacy of bowel cleansing for colonoscopy from the US Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology, the American Gastroenterological Association, and the American Society for Gastrointestinal Endoscopy. The US Multi-Society Task Force developed consensus statements and key clinical concepts addressing important aspects of bowel preparation for colonoscopy. The majority of consensus statements focus on individuals at average risk for inadequate bowel preparation. However, statements addressing individuals at risk for inadequate bowel preparation quality are also provided. The quality of a bowel preparation is defined as adequate when standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy. We recommend the use of a split-dose bowel preparation regimen and suggest that a 2 L regimen may be sufficient. A same-day regimen is recommended as an acceptable alternative for individuals undergoing afternoon colonoscopy, but we suggest that a same-day regimen is an inferior alternative for individuals undergoing morning colonoscopy. We recommend limiting dietary restrictions to the day before a colonoscopy, relying on either clear liquids or low-fiber/low-residue diets for the early and midday meals. We suggest the adjunctive use of oral simethicone for bowel preparation before colonoscopy. Routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit is also recommended, with a target of >90% for both rates.
Collapse
Affiliation(s)
- Brian C Jacobson
- Department of Medicine, Division of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Joseph C Anderson
- VA Medical Center, White River Junction, Vermont, USA
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA
- University of Connecticut School of Medicine, Farmington, Connecticut, USA
| | - Carol A Burke
- Department of Gastroenterology, Hepatology and Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jason A Dominitz
- Gastroenterology Section, VA Puget Sound Health Care System, Seattle, Washington, USA
- Department of Medicine, Division of Gastroenterology, University of Washington, Seattle, Washington, USA
| | | | - Folasade P May
- Department of Medicine, Division of Gastroenterology, Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California, USA
- Vatche and Tamar Manoukian Division of Digestive Diseases and Jonsson Comprehensive Cancer Center, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Swati G Patel
- University of Colorado Anschutz Medical Center, Aurora, Colorado, USA
- Rocky Mountain Regional Veterans Affairs Medical Center, Aurora, Colorado, USA
| | - Aasma Shaukat
- GI Section, Minneapolis VA Medical Center and University of Minnesota, Minneapolis, Minnesota, USA
| | - Douglas J Robertson
- VA Medical Center, White River Junction, Vermont, USA
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA
| |
Collapse
|
3
|
Jacobson BC, Anderson JC, Burke CA, Dominitz JA, Gross SA, May FP, Patel SG, Shaukat A, Robertson DJ. Optimizing Bowel Preparation Quality for Colonoscopy: Consensus Recommendations by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology 2025; 168:798-829. [PMID: 40047732 DOI: 10.1053/j.gastro.2025.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/24/2025]
Abstract
This document is an update to the 2014 recommendations for optimizing the adequacy of bowel cleansing for colonoscopy from the US Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology and the American Society for Gastrointestinal Endoscopy. The US Multi-Society Task Force developed consensus statements and key clinical concepts addressing important aspects of bowel preparation for colonoscopy. The majority of consensus statements focus on individuals at average risk for inadequate bowel preparation. However, statements addressing individuals at risk for inadequate bowel preparation quality are also provided. The quality of a bowel preparation is defined as adequate when standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy. We recommend the use of a split-dose bowel preparation regimen and suggest that a 2 L regimen may be sufficient. A same-day regimen is recommended as an acceptable alternative for individuals undergoing afternoon colonoscopy, but we suggest that a same-day regimen is an inferior alternative for individuals undergoing morning colonoscopy. We recommend limiting dietary restrictions to the day before a colonoscopy, relying on either clear liquids or low-fiber/low-residue diets for the early and midday meals. We suggest the adjunctive use of oral simethicone for bowel preparation before colonoscopy. Routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit is also recommended, with a target of >90% for both rates.
Collapse
Affiliation(s)
- Brian C Jacobson
- Department of Medicine, Division of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
| | - Joseph C Anderson
- VA Medical Center, White River Junction, Vermont; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire; University of Connecticut School of Medicine, Farmington, Connecticut
| | - Carol A Burke
- Department of Gastroenterology, Hepatology and Nutrition, Cleveland Clinic, Cleveland, Ohio
| | - Jason A Dominitz
- Gastroenterology Section, VA Puget Sound Health Care System, Seattle, Washington; Department of Medicine, Division of Gastroenterology, University of Washington, Seattle, Washington
| | | | - Folasade P May
- Department of Medicine, Division of Gastroenterology, Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, California; Vatche and Tamar Manoukian Division of Digestive Diseases and Jonsson Comprehensive Cancer Center, David Geffen School of Medicine, University of California, Los Angeles, California
| | - Swati G Patel
- University of Colorado Anschutz Medical Center, Aurora, Colorado; Rocky Mountain Regional Veterans Affairs Medical Center, Aurora, Colorado
| | - Aasma Shaukat
- GI Section, Minneapolis VA Medical Center and University of Minnesota, Minneapolis, Minnesota
| | - Douglas J Robertson
- VA Medical Center, White River Junction, Vermont; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire
| |
Collapse
|
4
|
Loeffler J, Di Pietro G, Chehab H, AlSheikh M, Kandlakunta H, Al Moussawi H, Daneshvar D, Buchen Y, Gurala D, Amarnath S, Abureesh M, Elfiky A, Gumaste V, Andrawes S. Effect of Cholecystectomy on Bubble Formation and Endoscopic Visualization: A Retrospective Cohort Study. Dig Dis Sci 2025; 70:1555-1559. [PMID: 39966287 DOI: 10.1007/s10620-025-08911-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Accepted: 02/02/2025] [Indexed: 02/20/2025]
Abstract
PURPOSE This study aimed to evaluate the association between cholecystectomy and colonic bubble formation during colonoscopy, METHODS: A single-center retrospective cohort study was conducted at Staten Island University Hospital. Researchers reviewed 348 colonoscopy reports, comparing patients with (n = 56) and without (n = 292) a history of cholecystectomy. Colonic bubble formation was assessed using a 0-3 scale (0 = no bubbles, 3 = severe bubbles). Secondary endpoints included polyp and adenoma detection, withdrawal and procedure times, bowel preparation quality, and repeat procedures. Statistical analysis included t-tests, Mann-Whitney U tests, and χ2 tests. RESULTS Patients with prior cholecystectomy had significantly higher incidence of severe bubble formation (score 3; 28.6% vs. 12%, p = 0.001), longer withdrawal times (18 ± 8 vs. 15 ± 5 min, p = 0.024), and increased need for repeat colonoscopies (10.7% vs. 2.1%, p = 0.001). No significant differences were found in adenoma detection, polyp detection, or bowel preparation quality between the two groups. CONCLUSION Cholecystectomy is associated with increased colonic bubble formation during colonoscopy, leading to longer withdrawal times and higher rates of repeat procedures. While this study did not find a difference in adenoma detection rates, the impaired visualization caused by bubbles may necessitate tailored bowel preparation strategies for patients with a history of cholecystectomy to optimize colonoscopy effectiveness.
Collapse
Affiliation(s)
- Jeffrey Loeffler
- Department of Internal Medicine, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA.
| | - Gaetano Di Pietro
- Department of Internal Medicine, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Hamed Chehab
- Department of Internal Medicine, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Mira AlSheikh
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Harika Kandlakunta
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Hassan Al Moussawi
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Danial Daneshvar
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Yosef Buchen
- Department of Internal Medicine, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Dineshreddy Gurala
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Shivantha Amarnath
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Mohammad Abureesh
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Ahmed Elfiky
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Vivek Gumaste
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| | - Sherif Andrawes
- Department of Gastroenterology and Hepatology, Northwell Health-Staten Island University Hospital, Staten Island, NY, USA
| |
Collapse
|
5
|
João M, Areia M, Alves S, Elvas L, Brito D, Saraiva S, Cadime AT. The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial. GE PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2024; 31:116-123. [PMID: 38572443 PMCID: PMC10987070 DOI: 10.1159/000530866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/16/2023] [Indexed: 04/05/2024]
Abstract
Introduction Current guidelines suggest adding oral simethicone to bowel preparation for colonoscopy. However, its effect on key quality indicators for screening colonoscopy remains unclear. The primary aim was to assess the rate of adequate bowel preparation in split-dose high-volume polyethylene glycol (PEG), with or without simethicone. Methods This is an endoscopist-blinded, randomized controlled trial, including patients scheduled for colonoscopy after a positive faecal immunochemical test. Patients were randomly assigned to 4 L of PEG split dose (PEG) or 4 L of PEG split dose plus 500 mg oral simethicone (PEG + simethicone). The Boston Bowel Preparation Scale (BBPS) score, the preparation quality regarding bubbles using the Colon Endoscopic Bubble Scale (CEBuS), ADR, CIR, and the intraprocedural use of simethicone were recorded. Results We included 191 and 197 patients in the PEG + simethicone group and the PEG group, respectively. When comparing the PEG + simethicone group versus the PEG group, no significant differences in adequate bowel preparation rates (97% vs. 93%; p = 0.11) were found. However, the bubble scale score was significantly lower in the PEG + simethicone group (0 [0] versus 2 [5], p < 0.01), as well as intraprocedural use of simethicone (7% vs. 37%; p < 0.01). ADR (62% vs. 61%; p = 0.86) and CIR (98% vs. 96%, p = 0.14) did not differ between both groups. Conclusion Adding oral simethicone to a split-bowel preparation resulted in a lower incidence of bubbles and a lower intraprocedural use of simethicone but no further improvement on the preparation quality or ADR.
Collapse
Affiliation(s)
- Mafalda João
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Miguel Areia
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Susana Alves
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Luís Elvas
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Daniel Brito
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Sandra Saraiva
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Ana Teresa Cadime
- Gastroenterology Department, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| |
Collapse
|
6
|
Keating E, Leyden J, O'Connor DB, Lahiff C. Unlocking quality in endoscopic mucosal resection. World J Gastrointest Endosc 2023; 15:338-353. [PMID: 37274555 PMCID: PMC10236981 DOI: 10.4253/wjge.v15.i5.338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/24/2023] [Accepted: 04/12/2023] [Indexed: 05/16/2023] Open
Abstract
A review of the development of the key performance metrics of endoscopic mucosal resection (EMR), learning from the experience of the establishment of widespread colonoscopy quality measurements. Potential future performance markers for both colonoscopy and EMR are also evaluated to ensure continued high quality performance is maintained with a focus service framework and predictors of patient outcome.
Collapse
Affiliation(s)
- Eoin Keating
- Department of Gastroenterology, Mater Misericordiae University Hospital, Dublin 7, Ireland
- School of Medicine, University College Dublin, Dublin 4, Ireland
| | - Jan Leyden
- Department of Gastroenterology, Mater Misericordiae University Hospital, Dublin 7, Ireland
- School of Medicine, University College Dublin, Dublin 4, Ireland
| | - Donal B O'Connor
- Department of Surgery, Tallaght University Hospital, Dublin 24, Ireland
- School of Medicine, Trinity College Dublin, Dublin 2, Ireland
| | - Conor Lahiff
- Department of Gastroenterology, Mater Misericordiae University Hospital, Dublin 7, Ireland
- School of Medicine, University College Dublin, Dublin 4, Ireland
| |
Collapse
|
7
|
Sun M, Yang G, Wang Y. Cleaning effect and tolerance of 16 bowel preparation regimens on adult patients before colonoscopy: a network meta-analysis. Int J Colorectal Dis 2023; 38:69. [PMID: 36905434 DOI: 10.1007/s00384-023-04355-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/20/2023] [Indexed: 03/12/2023]
Abstract
PURPOSE Colonoscopy is the gold standard for the diagnosis of colorectal cancer (CRC). Before a colonoscopy, an adequate bowel preparation (BP) is required. Currently, more novel regimens with different effects have been proposed and used successively. This network meta-analysis aims to compare the cleaning effects and patients' tolerability of several BP regimens. METHODS We performed a network meta-analysis of randomized controlled trials including sixteen kinds of BP regimens. We searched PubMed, Cochrane Library, Embase, and Web of Science databases. The outcomes of this study were bowel cleansing effect and tolerance. RESULTS We included a total of 40 articles with 13,064 patients. For the primary outcomes, polyethylene glycol (PEG) + ascorbic acid (Asc) + simethicone (Sim) (OR, 14.27, 95%CrI, 2.68-127.87) regimen is ranked first in Boston Bowel Preparation Scale (BBPS). PEG + Sim (OR, 2.0, 95%CrI 0.64-6.4) regimen is ranked first in Ottawa Bowel Preparation Scale (OBPS), but without significant differences. For the secondary outcomes, PEG + Sodium Picosulfate/Magnesium Citrate (SP/MC) (OR, 4.88e + 11, 95%CrI, 39.56-1.82e + 35) regimen is the best in cecal intubation rate(CIR). PEG + Sim (OR,1.5, 95%CrI, 1.0-2.2) regimen is ranked first in adenoma detection rate(ADR). Senna (OR, 3.23, 95%CrI, 1.04-9.97) and SP/MC (OR, 249.91, 95%CrI, 78.49-958.19) regimens are ranked first in abdominal pain and willingness to repeat, respectively. There is no significant difference in cecal intubation time (CIT), polyp detection rate (PDR), nausea, vomiting, and abdominal bloat. CONCLUSION PEG + Asc + Sim regimen is more effective at cleaning the bowel. PEG + SP/MC will be helpful to increase CIR. For ADR, PEG + Sim regimen will be more helpful. In addition, PEG + Asc + Sim is the least likely to cause abdominal bloat, while Senna regimen is more likely to cause abdominal pain. Patients prefer to re-use the SP/MC regimen for bowel preparation.
Collapse
Affiliation(s)
- Ming Sun
- College of Life Sciences and Biopharmaceuticals, Shenyang Pharmaceutical University, Shenyang, China
- Pharmacy Department of Chinese PLA No. 463 Hospital, Shenyang, China
| | - Guangzhao Yang
- Department of Outpatient, General Hospital of Northern Theater Command, Shenyang, China
| | - Yu Wang
- College of Life Sciences and Biopharmaceuticals, Shenyang Pharmaceutical University, Shenyang, China.
- Pharmacy Department of Chinese PLA No. 463 Hospital, Shenyang, China.
| |
Collapse
|
8
|
Speer T, Vickery K, Alfa M, Sáenz R. Minimizing the Risks of Simethicone in Endoscope Reprocessing. J Clin Gastroenterol 2023; 57:153-158. [PMID: 36508253 DOI: 10.1097/mcg.0000000000001807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 10/14/2022] [Indexed: 01/05/2023]
Abstract
This statement was written under the auspices of the World Gastroenterology Organization's Guidelines Committee. The authors are members of the Review Team of the WGO Endoscope Disinfection Guideline and have experience in endoscopy, endoscope reprocessing, and microbiology, including biofilms. During the preparation of the WGO Update on Endoscope Disinfection Guidelines, concerns about simethicone on endoscope channel surfaces compromising cleaning and disinfection were raised. Publications on simethicone, including modes of delivery, effectiveness, and risks, have been reviewed. The paper was written as a companion to the new guidelines with a focus on minimizing the risks of simethicone in endoscope reprocessing.
Collapse
Affiliation(s)
- Tony Speer
- The Royal Melbourne Hospital, Melbourne, Australia
| | | | | | - Roque Sáenz
- Facultad de Medicina, Universidad del Desarrollo, Clinica Alemana de Santiago, Santiago, Chile
| |
Collapse
|
9
|
Gubbiotti A, Spadaccini M, Badalamenti M, Hassan C, Repici A. Key factors for improving adenoma detection rate. Expert Rev Gastroenterol Hepatol 2022; 16:819-833. [PMID: 36151898 DOI: 10.1080/17474124.2022.2128761] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Colonoscopy is a fundamental tool in colorectal cancer (CRC) prevention. Nevertheless, one-fourth of colorectal neoplasms are still missed during colonoscopy, potentially being the main reason for post-colonoscopy colorectal cancer (PCCRC). Adenoma detection rate (ADR) is currently known as the best quality indicator correlating with PCCRC incidence. AREAS COVERED We performed a literature review in order to summarize evidences investigating key factors affecting ADR: endoscopists education and training, patient management, endoscopic techniques, improved navigation (exposition defect), and enhanced lesions recognition (vision defect) were considered. EXPERT OPINION 'Traditional' factors, such as split dose bowel preparation, adequate withdrawal time, and right colon second view, held a significant impact on ADR. Several devices and technologies have been developed to promote high-quality colonoscopy, however artificial intelligence may be considered the most promising tool for ADR improvement, provided that endoscopists education and recording are guaranteed.
Collapse
Affiliation(s)
- Alessandro Gubbiotti
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy.,IRCCS Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, Italy
| | - Marco Spadaccini
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy.,IRCCS Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, Italy
| | - Matteo Badalamenti
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy.,IRCCS Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, Italy
| | - Cesare Hassan
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy.,IRCCS Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, Italy
| | - Alessandro Repici
- Humanitas University, Department of Biomedical Sciences, Pieve Emanuele, Italy.,IRCCS Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, Italy
| |
Collapse
|
10
|
Cao RR, Wang L, Gao C, Pan JH, Yoshida EM, Li HY, Qi XS. Effect of oral simethicone on the quality of colonoscopy: A systematic review and meta-analysis of randomized controlled trials. J Dig Dis 2022; 23:134-148. [PMID: 35075814 DOI: 10.1111/1751-2980.13084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 01/17/2022] [Accepted: 01/21/2022] [Indexed: 01/30/2023]
Abstract
OBJECTIVE In this systematic review and meta-analysis, we aimed to investigate the effect of oral simethicone (SIM), an antifoaming agent, on the quality of colonoscopy in terms of bowel preparation quality, adenoma or polyp detection rate (ADR/PDR) and cecal intubation rate (CIR). METHODS All randomized controlled trials (RCTs) on the use of SIM during bowel preparation for colonoscopy published up to 17 March 2021 were identified from the PubMed, EMBASE and Cochrane Library databases. Bowel preparation quality, ADR/PDR/CIR, cecal intubation time (CIT), withdrawal time (WT), patients' tolerability, acceptability and volume of foam and bubbles were compared between the SIM and non-SIM groups. RESULTS Thirty-eight RCTs with 10 505 patients were included. Oral SIM significantly increased the rate of total Boston bowel preparation scale (BBPS) score ≥6 (risk ratio [RR] 1.13, P < 0.0001), acceptability (RR 1.15, P = 0.01) and the rate of no or minimal foam and bubbles (RR 1.28, P < 0.00001) and decreased abdominal distension (RR 0.64, P < 0.0001). However, it had no significant impact on overall ADR, overall PDR, CIR, CIT or WT. The rate of total BBPS score ≥6 remained significantly higher in the SIM group when a single-dose laxative regimen or a SIM dosage of ≥320 mg was employed; and ADR, PDR and CIR were significantly increased in the SIM group among colonoscopy clinicians who achieved an ADR <31%, PDR <45% and CIR <96%, respectively. CONCLUSIONS Oral SIM can improve bowel preparation quality, especially in patients receiving a SIM dosage of ≥320 mg or a single-dose laxative regimen. SIM may be preferred by junior colonoscopy physicians/trainees with a lower ADR/PDR or CIR.
Collapse
Affiliation(s)
- Rong Rong Cao
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China.,Postgraduate College, Jinzhou Medical University, Jinzhou, Liaoning Province, China
| | - Le Wang
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China.,China Medical University, Shenyang, Liaoning Province, China
| | - Cong Gao
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China
| | - Jia Hui Pan
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China
| | - Eric M Yoshida
- Division of Gastroenterology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Hong Yu Li
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China
| | - Xing Shun Qi
- Department of Gastroenterology, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China
| |
Collapse
|
11
|
Taveira F, Hassan C, Kaminski MF, Ponchon T, Benamouzig R, Bugajski M, de Castelbajac F, Cesaro P, Chergui H, Goran L, Minelli Grazioli L, Janičko M, Januszewicz W, Lamonaca L, Lenz J, Negreanu L, Repici A, Spada C, Spadaccini M, State M, Szlak J, Veseliny E, Dinis-Ribeiro M, Areia M. The Colon Endoscopic Bubble Scale (CEBuS): a two-phase evaluation study. Endoscopy 2022; 54:45-51. [PMID: 33285583 DOI: 10.1055/a-1331-4325] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS). METHODS This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone). RESULTS CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2. CONCLUSION CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.
Collapse
Affiliation(s)
- Filipe Taveira
- Department of Gastroenterology, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal
| | - Cesare Hassan
- Gastroenterology and Digestive Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Michal F Kaminski
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.,Department of Cancer Prevention, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.,Department of Health Management and Health Economics, University of Oslo, Oslo, Norway
| | - Thierry Ponchon
- Department of Hepatogastroenterology, Hôpital Edouard Herriot, Lyon, France
| | - Robert Benamouzig
- Service de Gastroentérologie, Hôpital Avicenne (APHP), Bobigny, France
| | - Marek Bugajski
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland
| | | | - Paola Cesaro
- Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italy
| | - Hasnae Chergui
- Service de Gastroentérologie, Hôpital Avicenne (APHP), Bobigny, France
| | - Loredana Goran
- Department of Gastroenterology, University Hospital, 'Carol Davila' University Bucharest, Romania
| | | | - Martin Janičko
- 2nd Department of Internal Medicine, Pavol Jozef Šafárik University, Košice, Slovakia
| | - Wladyslaw Januszewicz
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland
| | - Laura Lamonaca
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS -, Rozzano, Lombardia, Italy
| | - Jamila Lenz
- Department of Hepatogastroenterology, Hôpital Edouard Herriot, Lyon, France
| | - Lucian Negreanu
- Department of Gastroenterology, University Hospital, 'Carol Davila' University Bucharest, Romania
| | - Alessandro Repici
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS -, Rozzano, Lombardia, Italy
| | - Cristiano Spada
- Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italy.,Digestive Endoscopy Unit, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Marco Spadaccini
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS -, Rozzano, Lombardia, Italy
| | - Monica State
- Department of Gastroenterology, University Hospital, 'Carol Davila' University Bucharest, Romania
| | - Jakub Szlak
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland
| | - Eduard Veseliny
- 2nd Department of Internal Medicine, Pavol Jozef Šafárik University, Košice, Slovakia
| | - Mário Dinis-Ribeiro
- Center for Research in Health Technologies and Information Systems (CINTESIS), Faculty of Medicine, Porto, Portugal.,Gastroenterology Department, Portuguese Oncology Institute of Porto, Portugal
| | - Miguel Areia
- Department of Gastroenterology, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal.,Center for Research in Health Technologies and Information Systems (CINTESIS), Faculty of Medicine, Porto, Portugal
| |
Collapse
|
12
|
Di Leo M, Iannone A, Arena M, Losurdo G, Palamara MA, Iabichino G, Consolo P, Rendina M, Luigiano C, Di Leo A. Novel frontiers of agents for bowel cleansing for colonoscopy. World J Gastroenterol 2021; 27:7748-7770. [PMID: 34963739 PMCID: PMC8661374 DOI: 10.3748/wjg.v27.i45.7748] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/23/2021] [Accepted: 11/25/2021] [Indexed: 02/06/2023] Open
Abstract
The incidence of colorectal cancer (CRC) is characterized by rapid declines in the wake of widespread screening. Colonoscopy is the gold standard for CRC screening, but its accuracy is related to high quality of bowel preparation (BP). In this review, we aimed to summarized the current strategy to increase bowel cleansing before colonoscopy. Newly bowel cleansing agents were developed with the same efficacy of previous agent but requiring less amount of liquid to improve patients’ acceptability. The role of the diet before colonoscopy was also changed, as well the contribution of educational intervention and the use of adjunctive drugs to improve patients’ tolerance and/or quality of BP. The review also described BP in special situations, as lower gastrointestinal bleeding, elderly people, patients with chronic kidney disease, patients with inflammatory bowel disease, patients with congestive heart failure, inpatient, patient with previous bowel resection, pregnant/lactating patients. The review underlined the quality of BP should be described using a validate scale in colonoscopy report and it explored the available scales. Finally, the review explored the possible contribution of bowel cleansing in post-colonoscopy syndrome that can be related by a transient alteration of gut microbiota. Moreover, the study underlined several points needed to further investigations.
Collapse
Affiliation(s)
- Milena Di Leo
- Unit of Digestive Endoscopy, San Paolo Hospital, Milan 20090, Italy
| | - Andrea Iannone
- Section of Gastroenterology, Department of Emergency and Organ Transplantation, University of Bari, Bari 70124, Italy
| | - Monica Arena
- Unit of Digestive Endoscopy, San Paolo Hospital, Milan 20090, Italy
| | - Giuseppe Losurdo
- Section of Gastroenterology, Department of Emergency and Organ Transplantation, University of Bari, Bari 70124, Italy
| | | | | | - Pierluigi Consolo
- Unit of Digestive Endoscopy, University of Messina, Hospital "G. Martino", Messina 98121, Italy
| | - Maria Rendina
- Section of Gastroenterology, Department of Emergency and Organ Transplantation, University of Bari, Bari 70124, Italy
| | - Carmelo Luigiano
- Unit of Digestive Endoscopy, San Paolo Hospital, Milan 20090, Italy
| | - Alfredo Di Leo
- Section of Gastroenterology, Department of Emergency and Organ Transplantation, University of Bari, Bari 70124, Italy
| |
Collapse
|
13
|
Liu X, Yuan M, Li Z, Fei S, Zhao G. The Efficacy of Simethicone With Polyethylene Glycol for Bowel Preparation: A Systematic Review and Meta-Analysis. J Clin Gastroenterol 2021; 55:e46-e55. [PMID: 34085989 PMCID: PMC8183475 DOI: 10.1097/mcg.0000000000001527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Simethicone (SIM) is a commonly used antifoaming agent in the clinic. However, it has not been clarified whether SIM can improve the quality of intestinal preparation and the detection rates of adenomas (ADR) and polyps (PDR). This systematic review and meta-analysis were carried out to mainly evaluate the effect of SIM in bowel preparation for colonoscopy. MATERIALS AND METHODS An electronic and a manual search of the literature for studies was conducted in PubMed, EMBASE, and Web of Science in all published data before February 1, 2020. The primary outcomes were the quality of bowel preparation and the ADR and PDR. All the data were calculated using a pooled estimate of risk ratio with 95% confidence intervals, and a random-effect model was used for the calculation. RESULTS Eighteen randomized controlled trials with 7187 patients were included in this meta-analysis. Polyethylene glycol (PEG) with SIM improved colon cleansing (P<0.00001), PDR (P=0.006) and the detection rate of lesions in the right colon (P<0.00001) when compared with PEG alone. There was no difference in the ADR (P=0.68), withdrawal time (P=0.06), cecal intubation rate (P=0.98), and cecal intubation time (P=0.65) between 2 groups. The rate of abdominal bloating rate was higher in the PEG group, but there was no significant difference in vomiting (P=0.65), and abdominal pain (P=0.25). CONCLUSIONS SIM improves the quality of bowel cleanliness and PDR but not ADR. Besides, SIM improves the detection rate of lesions in the right colon and decreased abdominal bloating, but do not affect vomiting and abdominal pain or cramping.
Collapse
Affiliation(s)
- Xin Liu
- Departments of Gastroenterology
| | | | - Zhen Li
- Neurology, Affiliated Hospital of Xuzhou Medical University, Xuzhou
| | | | - Guodong Zhao
- Zhejiang University Kunshan Biotechnology Laboratory, Zhejiang University Kunshan Innovation Institute, Kunshan, Jiangsu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| |
Collapse
|
14
|
Zhang H, Gong J, Ma LS, Jiang T, Zhang H. Effect of antifoaming agent on benign colorectal tumors in colonoscopy: A meta-analysis. World J Clin Cases 2021; 9:3607-3622. [PMID: 34046460 PMCID: PMC8130091 DOI: 10.12998/wjcc.v9.i15.3607] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 02/25/2021] [Accepted: 03/12/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Although several trials have shown that the addition of antifoaming agents to polyethylene glycol (PEG) can improve bowel preparation, whether PEG plus antifoaming agents have a beneficial role in the detection of benign tumors during colonoscopy has yet to be confirmed. Our aim was to clarify whether adding simethicone to PEG solution could improve the detection of benign colorectal tumors.
AIM To clarify whether adding simethicone to PEG solution could improve the detection of benign colorectal tumors.
METHODS The PubMed, EMBASE, and Cochrane Library databases were searched for articles published prior to September 2019. The outcomes included the detection rates of colorectal adenomas and polyps.
RESULT Twenty studies were eligible. Although there was no difference in the colorectal adenoma detection rate (ADR), a significant effect of simethicone for diminutive adenomas (< 10 mm) was revealed in the group taking simethicone. We also found that simethicone could significantly improve the ADR in the proximal colon but did not affect the colorectal polyp detection rate. Furthermore, the subgroup analyses revealed a beneficial effect of simethicone on the ADR among Asians (P = 0.005) and those with an ADR < 25% (P = 0.003). Moreover, it was a significant finding that the low dose simethicone was as effective as the high dose one with respect to the detection of benign colorectal tumors.
CONCLUSION In summary, the addition of simethicone to PEG might improve the detection of diminutive adenomas in the right colon by colonoscopy in Asia. Low-dose simethicone was recommended for the detection of benign colorectal tumors. However, large clinical trials are necessary to validate our results and determine the ideal dose of simethicone.
Collapse
Affiliation(s)
- Hu Zhang
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, China
- Department of Gastroenterology, The Eighth Hospital of Wuhan, Wuhan 430014, Hubei Province, China
| | - Jing Gong
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, China
| | - Lin-Song Ma
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, China
| | - Ting Jiang
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, China
| | - Heng Zhang
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, China
| |
Collapse
|
15
|
Li DF, Luo MH, Du QQ, Zhang HY, Tian YH, Liu TT, Shi RY, Xiong F, Lai MG, Li YX, Luo S, Song Y, Wu BH, Xu ZL, Zhang DG, Yao J, Wang LS. Efficacy of low-dose versus high-dose simethicone with polyethylene glycol for bowel preparation: A prospective randomized controlled trial. J Gastroenterol Hepatol 2020; 35:1488-1494. [PMID: 32128877 DOI: 10.1111/jgh.15022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 02/20/2020] [Accepted: 02/22/2020] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIM Additional simethicone (SIM) can improve adequate bowel preparation and adenoma detection rate (ADR). However, there is no consensus on the optimal dose of SIM. In this study, we compared the adequate bowel preparation rate with supplementation of split-dose 2 L polyethylene glycol (PEG) with low-dose SIM (200 mg) versus high-dose SIM (1200 mg). METHODS This was a prospective, randomized, observer-blinded trial involving consecutive subjects undergoing colonoscopy. The primary outcome was adequate bowel preparation as assessed by Boston Bowel Preparation Scale (BBPS) score. RESULTS Four hundred subjects were randomly allocated to low-dose SIM or high-dose SIM group. Baseline characteristics were comparable in the two groups (P > 0.05). No significant between-group differences were observed with respect to total bubble scale (BS) (8.49 ± 1.00 vs 8.39 ± 1.10, P = 0.07), total BBPS score (8.70 ± 0.81 vs 8.29 ± 1.18, P = 0.98), ADR (33.68% vs 31.79%, P = 0.69) or withdrawal time (13 [range, 10-16] min vs 13 [10-15] min, P = 0.96). The intubation time in low-dose SIM group was significantly shorter than that in high-dose SIM group (8 (4-16) min vs 10 [6-17] min, P = 0.04). In addition, BS scores as well as diminutive ADR in right colon were superior in the low-dose SIM group (2.68 ± 0.59 vs 2.52 ± 0.73, P = 0.03 and 54.29% vs 30.30%, P = 0.046, respectively). CONCLUSION Addition of low-dose SIM to split-dose 2 L PEG was as effective as addition of high-dose SIM with respect to adequate bowel preparation, ADR and patient tolerance. However, low-dose SIM was superior with respect to intubation time, right colon BS scores, right colon diminutive ADR and cost savings.
Collapse
Affiliation(s)
- De-Feng Li
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ming-Han Luo
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Qing-Qing Du
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Hai-Yang Zhang
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Yan-Hui Tian
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ting-Ting Liu
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Rui-Yue Shi
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Feng Xiong
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ming-Guang Lai
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ying-Xue Li
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Su Luo
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Yang Song
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ben-Hua Wu
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Zheng-Lei Xu
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Ding-Guo Zhang
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Jun Yao
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| | - Li-Sheng Wang
- Department of Gastroenterology, the Second Clinical Medicine College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China
| |
Collapse
|
16
|
Hernández G, Gimeno-García AZ, Quintero E. Strategies to Improve Inadequate Bowel Preparation for Colonoscopy. Front Med (Lausanne) 2019; 6:245. [PMID: 31781565 PMCID: PMC6857107 DOI: 10.3389/fmed.2019.00245] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Accepted: 10/15/2019] [Indexed: 12/26/2022] Open
Abstract
Bowel cleansing is one of the most important parameters included in the evaluation of colonoscopy quality. The available evidence suggests that inadequate bowel preparation reduces the diagnostic yield of colorectal neoplasia and increases post-colonoscopy colorectal cancer risk. Nowadays, up to 30% of patients referred for colonoscopy have a poor bowel cleansing. Recently, several studies have analyzed the risk factors for inadequate bowel cleansing as well as the strategies to optimize bowel preparation. In this review, we have focused on summarizing the available evidence in this field.
Collapse
Affiliation(s)
- Goretti Hernández
- Servicio de Gastroenterología, Hospital Universitario de Canarias, Instituto Universitario de Tecnologías Biomédicas (ITB) & Centro de Investigación Biomédica de Canarias (CIBICAN), Santa Cruz de Tenerife, Spain
| | - Antonio Z Gimeno-García
- Servicio de Gastroenterología, Hospital Universitario de Canarias, Instituto Universitario de Tecnologías Biomédicas (ITB) & Centro de Investigación Biomédica de Canarias (CIBICAN), Santa Cruz de Tenerife, Spain
| | - Enrique Quintero
- Servicio de Gastroenterología, Hospital Universitario de Canarias, Instituto Universitario de Tecnologías Biomédicas (ITB) & Centro de Investigación Biomédica de Canarias (CIBICAN), Santa Cruz de Tenerife, Spain.,Departamento de Medicina Interna, Universidad de La Laguna, Santa Cruz de Tenerife, Spain
| |
Collapse
|