1
|
Lin YH, Lin CT, Chang YH, Lin YY, Chen JJ, Huang CR, Hsu YW, You WC. Development and Validation of a 3D Resnet Model for Prediction of Lymph Node Metastasis in Head and Neck Cancer Patients. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024; 37:679-687. [PMID: 38343258 PMCID: PMC11031546 DOI: 10.1007/s10278-023-00938-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 09/26/2023] [Accepted: 09/26/2023] [Indexed: 04/20/2024]
Abstract
The accurate diagnosis and staging of lymph node metastasis (LNM) are crucial for determining the optimal treatment strategy for head and neck cancer patients. We aimed to develop a 3D Resnet model and investigate its prediction value in detecting LNM. This study enrolled 156 head and neck cancer patients and analyzed 342 lymph nodes segmented from surgical pathologic reports. The patients' clinical and pathological data related to the primary tumor site and clinical and pathology T and N stages were collected. To predict LNM, we developed a dual-pathway 3D Resnet model incorporating two Resnet models with different depths to extract features from the input data. To assess the model's performance, we compared its predictions with those of radiologists in a test dataset comprising 38 patients. The study found that the dimensions and volume of LNM + were significantly larger than those of LNM-. Specifically, the Y and Z dimensions showed the highest sensitivity of 84.6% and specificity of 72.2%, respectively, in predicting LNM + . The analysis of various variations of the proposed 3D Resnet model demonstrated that Dual-3D-Resnet models with a depth of 34 achieved the highest AUC values of 0.9294. In the validation test of 38 patients and 86 lymph nodes dataset, the 3D Resnet model outperformed both physical examination and radiologists in terms of sensitivity (80.8% compared to 50.0% and 91.7%, respectively), specificity(90.0% compared to 88.5% and 65.4%, respectively), and positive predictive value (77.8% compared to 66.7% and 55.0%, respectively) in detecting individual LNM + . These results suggest that the 3D Resnet model can be valuable for accurately identifying LNM + in head and neck cancer patients. A prospective trial is needed to evaluate further the role of the 3D Resnet model in determining LNM + in head and neck cancer patients and its impact on treatment strategies and patient outcomes.
Collapse
Affiliation(s)
- Yi-Hui Lin
- Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung City, Taiwan
| | - Chieh-Ting Lin
- College of Artificial Intelligence, National Yang-Ming Chiao Tung University, Hsinchu City, Taiwan
| | - Ya-Han Chang
- Department of Computer Science, National Yang-Ming Chiao Tung University, Hsinchu City, Taiwan
| | - Yen-Yu Lin
- Department of Computer Science, National Yang-Ming Chiao Tung University, Hsinchu City, Taiwan
| | - Jen-Jee Chen
- College of Artificial Intelligence, National Yang-Ming Chiao Tung University, Hsinchu City, Taiwan
| | - Chun-Rong Huang
- Academy of Innovative Semiconductor and Sustainable Manufacturing, National Cheng Kung University, Tainan City, Taiwan
| | - Yu-Wei Hsu
- Cancer Prevention and Control Center, Taichung Veterans General Hospital, Taichung City, Taiwan
| | - Weir-Chiang You
- Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung City, Taiwan.
| |
Collapse
|
2
|
Karimipourfard M, Sina S, Mahani H, Alavi M, Yazdi M. Impact of deep learning-based multiorgan segmentation methods on patient-specific internal dosimetry in PET/CT imaging: A comparative study. J Appl Clin Med Phys 2024; 25:e14254. [PMID: 38214349 PMCID: PMC10860559 DOI: 10.1002/acm2.14254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/29/2023] [Accepted: 11/30/2023] [Indexed: 01/13/2024] Open
Abstract
PURPOSE Accurate and fast multiorgan segmentation is essential in image-based internal dosimetry in nuclear medicine. While conventional manual PET image segmentation is widely used, it suffers from both being time-consuming as well as subject to human error. This study exploited 2D and 3D deep learning (DL) models. Key organs in the trunk of the body were segmented and then used as a reference for networks. METHODS The pre-trained p2p-U-Net-GAN and HighRes3D architectures were fine-tuned with PET-only images as inputs. Additionally, the HighRes3D model was alternatively trained with PET/CT images. Evaluation metrics such as sensitivity (SEN), specificity (SPC), intersection over union (IoU), and Dice scores were considered to assess the performance of the networks. The impact of DL-assisted PET image segmentation methods was further assessed using the Monte Carlo (MC)-derived S-values to be used for internal dosimetry. RESULTS A fair comparison with manual low-dose CT-aided segmentation of the PET images was also conducted. Although both 2D and 3D models performed well, the HighRes3D offers superior performance with Dice scores higher than 0.90. Key evaluation metrics such as SEN, SPC, and IoU vary between 0.89-0.93, 0.98-0.99, and 0.87-0.89 intervals, respectively, indicating the encouraging performance of the models. The percentage differences between the manual and DL segmentation methods in the calculated S-values varied between 0.1% and 6% with a maximum attributed to the stomach. CONCLUSION The findings prove while the incorporation of anatomical information provided by the CT data offers superior performance in terms of Dice score, the performance of HighRes3D remains comparable without the extra CT channel. It is concluded that both proposed DL-based methods provide automated and fast segmentation of whole-body PET/CT images with promising evaluation metrics. Between them, the HighRes3D is more pronounced by providing better performance and can therefore be the method of choice for 18F-FDG-PET image segmentation.
Collapse
Affiliation(s)
| | - Sedigheh Sina
- Department of Ray‐Medical EngineeringShiraz UniversityShirazIran
- Radiation Research CenterShiraz UniversityShirazIran
| | - Hojjat Mahani
- Radiation Applications Research SchoolNuclear Science and Technology Research InstituteTehranIran
| | - Mehrosadat Alavi
- Department of Nuclear MedicineShiraz University of Medical SciencesShirazIran
| | - Mehran Yazdi
- School of Electrical and Computer EngineeringShiraz UniversityShirazIran
| |
Collapse
|
3
|
Singhrao K, Dugan CL, Calvin C, Pelayo L, Yom SS, Chan JW, Scholey JE, Singer L. Evaluating the Hounsfield unit assignment and dose differences between CT-based standard and deep learning-based synthetic CT images for MRI-only radiation therapy of the head and neck. J Appl Clin Med Phys 2024; 25:e14239. [PMID: 38128040 PMCID: PMC10795453 DOI: 10.1002/acm2.14239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 11/22/2023] [Accepted: 11/29/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND Magnetic resonance image only (MRI-only) simulation for head and neck (H&N) radiotherapy (RT) could allow for single-image modality planning with excellent soft tissue contrast. In the MRI-only simulation workflow, synthetic computed tomography (sCT) is generated from MRI to provide electron density information for dose calculation. Bone/air regions produce little MRI signal which could lead to electron density misclassification in sCT. Establishing the dosimetric impact of this error could inform quality assurance (QA) procedures using MRI-only RT planning or compensatory methods for accurate dosimetric calculation. PURPOSE The aim of this study was to investigate if Hounsfield unit (HU) voxel misassignments from sCT images result in dosimetric errors in clinical treatment plans. METHODS Fourteen H&N cancer patients undergoing same-day CT and 3T MRI simulation were retrospectively identified. MRI was deformed to the CT using multimodal deformable image registration. sCTs were generated from T1w DIXON MRIs using a commercially available deep learning-based generator (MRIplanner, Spectronic Medical AB, Helsingborg, Sweden). Tissue voxel assignment was quantified by creating a CT-derived HU threshold contour. CT/sCT HU differences for anatomical/target contours and tissue classification regions including air (<250 HU), adipose tissue (-250 HU to -51 HU), soft tissue (-50 HU to 199 HU), spongy (200 HU to 499 HU) and cortical bone (>500 HU) were quantified. t-test was used to determine if sCT/CT HU differences were significant. The frequency of structures that had a HU difference > 80 HU (the CT window-width setting for intra-cranial structures) was computed to establish structure classification accuracy. Clinical intensity modulated radiation therapy (IMRT) treatment plans created on CT were retrospectively recalculated on sCT images and compared using the gamma metric. RESULTS The mean ratio of sCT HUs relative to CT for air, adipose tissue, soft tissue, spongy and cortical bone were 1.7 ± 0.3, 1.1 ± 0.1, 1.0 ± 0.1, 0.9 ± 0.1 and 0.8 ± 0.1 (value of 1 indicates perfect agreement). T-tests (significance set at t = 0.05) identified differences in HU values for air, spongy and cortical bone in sCT images compared to CT. The structures with sCT/CT HU differences > 80 HU of note were the left and right (L/R) cochlea and mandible (>79% of the tested cohort), the oral cavity (for 57% of the tested cohort), the epiglottis (for 43% of the tested cohort) and the L/R TM joints (occurring > 29% of the cohort). In the case of the cochlea and TM joints, these structures contain dense bone/air interfaces. In the case of the oral cavity and mandible, these structures suffer the additional challenge of being positionally altered in CT versus MRI simulation (due to a non-MR safe immobilizing bite block requiring absence of bite block in MR). Finally, the epiglottis HU assignment suffers from its small size and unstable positionality. Plans recalculated on sCT yielded global/local gamma pass rates of 95.5% ± 2% (3 mm, 3%) and 92.7% ± 2.1% (2 mm, 2%). The largest mean differences in D95, Dmean , D50 dose volume histogram (DVH) metrics for organ-at-risk (OAR) and planning tumor volumes (PTVs) were 2.3% ± 3.0% and 0.7% ± 1.9% respectively. CONCLUSIONS In this cohort, HU differences of CT and sCT were observed but did not translate into a reduction in gamma pass rates or differences in average PTV/OAR dose metrics greater than 3%. For sites such as the H&N where there are many tissue interfaces we did not observe large scale dose deviations but further studies using larger retrospective cohorts are merited to establish the variation in sCT dosimetric accuracy which could help to inform QA limits on clinical sCT usage.
Collapse
Affiliation(s)
- Kamal Singhrao
- Department of Radiation OncologyBrigham and Women's Hospital, Dana‐Farber Cancer Institute, Harvard Medical SchoolBostonMassachusettsUSA
| | - Catherine Lu Dugan
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| | - Christina Calvin
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| | - Luis Pelayo
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| | - Sue Sun Yom
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| | - Jason Wing‐Hong Chan
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| | | | - Lisa Singer
- Department of Radiation OncologyUniversity of California, San FranciscoSan FranciscoCaliforniaUSA
| |
Collapse
|
4
|
Weisman AJ, Huff DT, Govindan RM, Chen S, Perk TG. Multi-organ segmentation of CT via convolutional neural network: impact of training setting and scanner manufacturer. Biomed Phys Eng Express 2023; 9:065021. [PMID: 37725928 DOI: 10.1088/2057-1976/acfb06] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/19/2023] [Indexed: 09/21/2023]
Abstract
Objective. Automated organ segmentation on CT images can enable the clinical use of advanced quantitative software devices, but model performance sensitivities must be understood before widespread adoption can occur. The goal of this study was to investigate performance differences between Convolutional Neural Networks (CNNs) trained to segment one (single-class) versus multiple (multi-class) organs, and between CNNs trained on scans from a single manufacturer versus multiple manufacturers.Methods. The multi-class CNN was trained on CT images obtained from 455 whole-body PET/CT scans (413 for training, 42 for testing) taken with Siemens, GE, and Phillips PET/CT scanners where 16 organs were segmented. The multi-class CNN was compared to 16 smaller single-class CNNs trained using the same data, but with segmentations of only one organ per model. In addition, CNNs trained on Siemens-only (N = 186) and GE-only (N = 219) scans (manufacturer-specific) were compared with CNNs trained on data from both Siemens and GE scanners (manufacturer-mixed). Segmentation performance was quantified using five performance metrics, including the Dice Similarity Coefficient (DSC).Results. The multi-class CNN performed well compared to previous studies, even in organs usually considered difficult auto-segmentation targets (e.g., pancreas, bowel). Segmentations from the multi-class CNN were significantly superior to those from smaller single-class CNNs in most organs, and the 16 single-class models took, on average, six times longer to segment all 16 organs compared to the single multi-class model. The manufacturer-mixed approach achieved minimally higher performance over the manufacturer-specific approach.Significance. A CNN trained on contours of multiple organs and CT data from multiple manufacturers yielded high-quality segmentations. Such a model is an essential enabler of image processing in a software device that quantifies and analyzes such data to determine a patient's treatment response. To date, this activity of whole organ segmentation has not been adopted due to the intense manual workload and time required.
Collapse
Affiliation(s)
- Amy J Weisman
- AIQ Solutions, Madison, WI, United States of America
| | - Daniel T Huff
- AIQ Solutions, Madison, WI, United States of America
| | | | - Song Chen
- Department of Nuclear Medicine, The First Hospital of China Medical University, Shenyang, Liaoning, People's Republic of China
| | | |
Collapse
|
5
|
Martinez-Zubiaurre I, Hellevik T. Cancer-associated fibroblasts in radiotherapy: Bystanders or protagonists? Cell Commun Signal 2023; 21:108. [PMID: 37170098 PMCID: PMC10173661 DOI: 10.1186/s12964-023-01093-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 02/26/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND The primary goal of radiotherapy (RT) is to induce cellular damage on malignant cells; however, it is becoming increasingly recognized the important role played by the tumor microenvironment (TME) in therapy outcomes. Therapeutic irradiation of tumor lesions provokes profound cellular and biological reconfigurations within the TME that ultimately may influence the fate of the therapy. MAIN CONTENT Cancer-associated fibroblasts (CAFs) are known to participate in all stages of cancer progression and are increasingly acknowledged to contribute to therapy resistance. Accumulated evidence suggests that, upon radiation, fibroblasts/CAFs avoid cell death but instead enter a permanent senescent state, which in turn may influence the behavior of tumor cells and other components of the TME. Despite the proposed participation of senescent fibroblasts on tumor radioprotection, it is still incompletely understood the impact that RT has on CAFs and the ultimate role that irradiated CAFs have on therapy outcomes. Some of the current controversies may emerge from generalizing observations obtained using normal fibroblasts and CAFs, which are different cell entities that may respond differently to radiation exposure. CONCLUSION In this review we present current knowledge on the field of CAFs role in radiotherapy; we discuss the potential tumorigenic functions of radiation-induced senescent fibroblasts and CAFs and we make an effort to integrate the knowledge emerging from preclinical experimentation with observations from the clinics. Video Abstract.
Collapse
Affiliation(s)
- Inigo Martinez-Zubiaurre
- Department of Clinical Medicine, Faculty of Health Sciences, UiT The Arctic University of Norway, Postbox 6050, 9037, Langnes, Tromsö, Norway.
| | - Turid Hellevik
- Department of Radiation Oncology, University Hospital of North Norway, Postbox 100, 9038, Tromsö, Norway
| |
Collapse
|
6
|
Volpe S, Isaksson LJ, Zaffaroni M, Pepa M, Raimondi S, Botta F, Lo Presti G, Vincini MG, Rampinelli C, Cremonesi M, de Marinis F, Spaggiari L, Gandini S, Guckenberger M, Orecchia R, Jereczek-Fossa BA. Impact of image filtering and assessment of volume-confounding effects on CT radiomic features and derived survival models in non-small cell lung cancer. Transl Lung Cancer Res 2022; 11:2452-2463. [PMID: 36636424 PMCID: PMC9830263 DOI: 10.21037/tlcr-22-248] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/31/2022] [Indexed: 11/24/2022]
Abstract
Background No evidence supports the choice of specific imaging filtering methodologies in radiomics. As the volume of the primary tumor is a well-recognized prognosticator, our purpose is to assess how filtering may impact the feature/volume dependency in computed tomography (CT) images of non-small cell lung cancer (NSCLC), and if such impact translates into differences in the performance of survival modeling. The role of lesion volume in model performances was also considered and discussed. Methods Four-hundred seventeen CT images NSCLC patients were retrieved from the NSCLC-Radiomics public repository. Pre-processing and features extraction were implemented using Pyradiomics v3.0.1. Features showing high correlation with volume across original and filtered images were excluded. Cox proportional hazards (PH) with least absolute shrinkage and selection operator (LASSO) regularization and CatBoost models were built with and without volume, and their concordance (C-) indices were compared using Wilcoxon signed-ranked test. The Mann Whitney U test was used to assess model performances after stratification into two groups based on low- and high-volume lesions. Results Radiomic models significantly outperformed models built on only clinical variables and volume. However, the exclusion/inclusion of volume did not generally alter the performances of radiomic models. Overall, performances were not substantially affected by the choice of either imaging filter (overall C-index 0.539-0.590 for Cox PH and 0.589-0.612 for CatBoost). The separation of patients with high-volume lesions resulted in significantly better performances in 2/10 and 7/10 cases for Cox PH and CatBoost models, respectively. Both low- and high-volume models performed significantly better with the inclusion of radiomic features (P<0.0001), but the improvement was largest in the high-volume group (+10.2% against +8.7% improvement for CatBoost models and +10.0% against +5.4% in Cox PH models). Conclusions Radiomic features complement well-known prognostic factors such as volume, but their volume-dependency is high and should be managed with vigilance. The informative content of radiomic features may be diminished in small lesion volumes, which could limit the applicability of radiomics in early-stage NSCLC, where tumors tend to be small. Our results also suggest an advantage of CatBoost models over the Cox PH models.
Collapse
Affiliation(s)
- Stefania Volpe
- Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy;,Department of Oncology and Hemato-Oncology, University of Milan, Milan, Italy
| | | | - Mattia Zaffaroni
- Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Matteo Pepa
- Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Sara Raimondi
- Department of Experimental Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Francesca Botta
- Medical Physics Unit, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Giuliana Lo Presti
- Department of Experimental Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Maria Giulia Vincini
- Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Cristiano Rampinelli
- Department of Radiology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Marta Cremonesi
- Radiation Research Unit, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Filippo de Marinis
- Division of Thoracic Oncology, European Institute of Oncology, IRCCS, Milan, Italy
| | - Lorenzo Spaggiari
- Department of Oncology and Hemato-Oncology, University of Milan, Milan, Italy;,Division of Thoracic Surgery, European Institute of Oncology IRCCS, Milan, Italy
| | - Sara Gandini
- Department of Experimental Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Roberto Orecchia
- Scientific Direction, IEO, European Institute of Oncology IRCCS, Milan, Italy
| | - Barbara Alicja Jereczek-Fossa
- Division of Radiation Oncology, IEO, European Institute of Oncology IRCCS, Milan, Italy;,Department of Oncology and Hemato-Oncology, University of Milan, Milan, Italy
| |
Collapse
|
7
|
van Dijk LV, Fuller CD. Artificial Intelligence and Radiomics in Head and Neck Cancer Care: Opportunities, Mechanics, and Challenges. Am Soc Clin Oncol Educ Book 2021; 41:1-11. [PMID: 33929877 DOI: 10.1200/edbk_320951] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The advent of large-scale high-performance computing has allowed the development of machine-learning techniques in oncologic applications. Among these, there has been substantial growth in radiomics (machine-learning texture analysis of images) and artificial intelligence (which uses deep-learning techniques for "learning algorithms"); however, clinical implementation has yet to be realized at scale. To improve implementation, opportunities, mechanics, and challenges, models of imaging-enabled artificial intelligence approaches need to be understood by clinicians who make the treatment decisions. This article aims to convey the basic conceptual premises of radiomics and artificial intelligence using head and neck cancer as a use case. This educational overview focuses on approaches for head and neck oncology imaging, detailing current research efforts and challenges to implementation.
Collapse
Affiliation(s)
- Lisanne V van Dijk
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, TX.,Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Clifton D Fuller
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
8
|
Luo HC, Fu ZC, Wang XP, Cai LJ, Wang FM, Yin Q, Lin G, Chen ZH, Liao SG. Treating the primary in low burden metastatic prostate cancer: Where do we stand? Medicine (Baltimore) 2020; 99:e23715. [PMID: 33371121 PMCID: PMC7748322 DOI: 10.1097/md.0000000000023715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 11/16/2020] [Indexed: 11/30/2022] Open
Abstract
On the basis of endocrine therapy for patients with low burden metastatic prostate cancer (LBMP), the clinical efficacy and quality of life were compared between prostate-only directed radiotherapy (PODT) and prostate and metastasis radiotherapy (PMRT).From November 2009 to November 2015, total 91 patients newly diagnosed with LBMP were retrospectively analyzed, of which 52 patients received PODT and 39 patients received PMRT. The biochemical failure free interval (IBF), prostate specific survival (PCSS), and overall survival (OS) time were compared between the 2 groups, and expanded prostate cancer index composite (EPIC) scale was used to evaluate the difference in quality of life between the 2 groups.The median IBF of the PODT group was 31 months, which was significantly lower than the 39 months of the PMRT group (P < .05); the 5-year OS and PCSS were 58.9%, 65.3% in PODT group, and 58.9%, 71.79% in PMRT group, respectively. There was no significant between the 2 groups (P > .05); the side effects of acute radiotherapy in PMRT group were significantly higher than PODT group (P < .05), especially in bone marrow suppression and gastrointestinal reactions; The scores of urinary system function and intestinal system function in PMRT group were significantly higher than PODT group at the end of radiotherapy, 3 months after radiotherapy, and 6 months after radiotherapy (P < .05). The score of sexual function in PMRT group was significantly lower than that in PODT group after radiotherapy (P < .05), and higher than that in PORT group at other follow-up time points (P < .05). The hormone function was decreased at each follow-up time point in 2 groups, and there was no significant difference between the 2 groups (P > .05).Patients with LBMP receiving PMRT can improve IBF, but cannot increase PCSS and OS, and increase the incidence of acute radiation injury.
Collapse
Affiliation(s)
| | | | | | | | - Feng-Mei Wang
- Department of Gynaecology and Obstetrics, The 900th Hospital of Joint Logistics Force (Xiamen Dongfang Hospital), Fuzhou
| | - Qin Yin
- Department of Oncology, Longyan People's Hospital, Longyan
| | - Guishan Lin
- Department of Radiation Oncology, Fujian Province's Hospital, Fujian
| | | | - Shao-Guang Liao
- Department of Oncology, Taizhou First People's Hospital (Huangyan Hospital, Wenzhou Medical University), Taizhou, Zhejiang, China
| |
Collapse
|