Siddiqi N, Tchou P, Niebauer MJ, Wilkoff BL, Varma N. Influence of "high" defibrillation thresholds on patient survival and impact of system modification. J Cardiovasc Electrophysiol 2021; 33:234-240. [PMID: 34911148 DOI: 10.1111/jce.15326] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 08/20/2021] [Accepted: 10/20/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To test whether a high defibrillation threshold (DFT) marks patients with poor outcomes which are improved when DFT is decreased by system modification (subcutaneous coil implant; SM). BACKGROUND The electrical substrate generating fast ventricular arrhythmias may generate poor outcomes among patients treated with implantable cardioverter-defibrillators (ICDs), even when arrhythmias are treated successfully. Since patients with high DFTs have increased mortality, we contrasted survival among patients with high DFT treated with and without SM. METHODS We studied consecutive patients undergoing ICD implantation and DFT testing at Cleveland Clinic over a 14-year period. High DFT was defined as successful defibrillation by shock strength >25 J or ≤10 J of maximal device output. Mortality was recorded using the Social Security Death Index. Survival was compared among those high DFT patients receiving SM versus the remainder. RESULTS Out of 6353 patients tested, 191 (3%) had high DFT (32.1 ± 3.7 J) versus 13.9 ± 4.9 J in the remainder ("acceptable DFT," p < .001). One hundred twenty-one high DFT patients (63%; 33.3 ± 3.4 J) underwent SM, which significantly decreased DFT (24.8 ± 5.9 J; p < .001). Seventy patients (37%; 30.3 ± 3.3 J) did not undergo SM. During follow-up, 38% (2363/6162; 7.8 yrs) patients with acceptable DFT died versus 48% high DFT patients (91/191; 5.6 yrs.; p < .001). Concomitantly, 48% patients with SM (58/121) died, as compared to 47% patients (33/70) without SM (p = .91); median follow-up 4.9 yrs). CONCLUSION Patients with high DFT have a higher mortality than those with acceptable DFT. The additional subcutaneous coil implant decreases DFT to an acceptable range but does not appear to improve survival. The electrical substrate underlying high DFT appears to determine survival.
Collapse
Affiliation(s)
- Najmul Siddiqi
- Department of Cardiovascular Medicine, Cleveland Clinic, Section of Cardiac Pacing and Electrophysiology, Cleveland, Ohio, USA
| | - Patrick Tchou
- Department of Cardiovascular Medicine, Cleveland Clinic, Section of Cardiac Pacing and Electrophysiology, Cleveland, Ohio, USA
| | - Mark J Niebauer
- Department of Cardiovascular Medicine, Cleveland Clinic, Section of Cardiac Pacing and Electrophysiology, Cleveland, Ohio, USA
| | - Bruce L Wilkoff
- Department of Cardiovascular Medicine, Cleveland Clinic, Section of Cardiac Pacing and Electrophysiology, Cleveland, Ohio, USA
| | - Niraj Varma
- Department of Cardiovascular Medicine, Cleveland Clinic, Section of Cardiac Pacing and Electrophysiology, Cleveland, Ohio, USA
| |
Collapse
|
2
|
Burri H, Starck C, Auricchio A, Biffi M, Burri M, D'Avila A, Deharo JC, Glikson M, Israel C, Lau CP, Leclercq C, Love CJ, Nielsen JC, Vernooy K, Dagres N, Boveda S, Butter C, Marijon E, Braunschweig F, Mairesse GH, Gleva M, Defaye P, Zanon F, Lopez-Cabanillas N, Guerra JM, Vassilikos VP, Martins Oliveira M. EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS). Europace 2021; 23:983-1008. [PMID: 33878762 DOI: 10.1093/europace/euaa367] [Citation(s) in RCA: 94] [Impact Index Per Article: 31.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
With the global increase in device implantations, there is a growing need to train physicians to implant pacemakers and implantable cardioverter-defibrillators. Although there are international recommendations for device indications and programming, there is no consensus to date regarding implantation technique. This document is founded on a systematic literature search and review, and on consensus from an international task force. It aims to fill the gap by setting standards for device implantation.
Collapse
Affiliation(s)
- Haran Burri
- Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva, Switzerland
| | - Christoph Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Center, Berlin, Augustenburger Pl. 1, 13353 Berlin, Germany.,German Center of Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany.,Steinbeis University Berlin, Institute (STI) of Cardiovascular Perfusion, Berlin, Germany
| | - Angelo Auricchio
- Fondazione Cardiocentro Ticino, Via Tesserete 48, CH-6900 Lugano, Switzerland
| | - Mauro Biffi
- Azienda Ospedaliero-Universitaria di Bologna, Policlinico S.Orsola-Malpighi, Università di Bologna, Bologna, Italy
| | - Mafalda Burri
- Division of Scientific Information, University of Geneva, Rue Michel Servet 1, 1211 Geneva, Switzerland
| | - Andre D'Avila
- Serviço de Arritmia Cardíaca-Hospital SOS Cardio, 2 Florianópolis, SC, Brazil.,Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | | | - Carsten Israel
- Department of Cardiology, Bethel-Clinic Bielefeld, Burgsteig 13, 33617, Bielefeld, Germany
| | - Chu-Pak Lau
- Division of Cardiology, University of Hong Kong, Queen Mary Hospital, Pok Fu Lam, Hong Kong
| | | | - Charles J Love
- Johns Hopkins Hospital and School of Medicine, Baltimore, MD, USA
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 161, 8200 Aarhus, Denmark
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands.,Department of Cardiology, Radboud University Medical Center (Radboudumc), Nijmegen, The Netherlands
| | | | - Nikolaos Dagres
- Department of Electrophysiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany
| | - Serge Boveda
- Heart Rhythm Department, Clinique Pasteur, 31076 Toulouse, France
| | - Christian Butter
- Department of Cardiology, Heart Center Brandenburg, Chefarzt, Abteilung Kardiologie, Berlin, Germany
| | - Eloi Marijon
- University of Paris, Head of Cardiac Electrophysiology Section, European Georges Pompidou Hospital, 20 Rue Leblanc, 75908 Paris Cedex 15, France
| | | | - Georges H Mairesse
- Department of Cardiology-Electrophysiology, Cliniques du Sud Luxembourg-Vivalia, rue des Deportes 137, BE-6700 Arlon, Belgium
| | - Marye Gleva
- Washington University in St Louis, St Louis, MO, USA
| | - Pascal Defaye
- CHU Grenoble Alpes, Unite de Rythmologie, Service De Cardiologie, CS10135, 38043 Grenoble Cedex 09, France
| | - Francesco Zanon
- Arrhythmia and Electrophysiology Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy
| | | | - Jose M Guerra
- Department of Cardiology, Hospital de la Santa Creu i Sant Pau, Universidad Autonoma de Barcelona, CIBERCV, Barcelona, Spain
| | - Vassilios P Vassilikos
- Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece.,3rd Cardiology Department, Hippokrateio General Hospital, Thessaloniki, Greece
| | - Mario Martins Oliveira
- Department of Cardiology, Hospital Santa Marta, Rua Santa Marta, 1167-024 Lisbon, Portugal
| |
Collapse
|
3
|
Cheng Y, Li H, Wang L, Li J, Kang W, Rao P, Zhou F, Wang X, Huang C. Optogenetic approaches for termination of ventricular tachyarrhythmias after myocardial infarction in rats in vivo. JOURNAL OF BIOPHOTONICS 2020; 13:e202000003. [PMID: 32246523 DOI: 10.1002/jbio.202000003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 03/24/2020] [Accepted: 03/25/2020] [Indexed: 06/11/2023]
Abstract
Cardiac optogenetics facilitates the painless manipulation of the heart with optical energy and was recently shown to terminate ventricular tachycardia (VT) in explanted mice heart. This study aimed to evaluate the optogenetic-based termination of induced VT under ischemia in an open-chest rat model and to develop an optimal, optical-manipulation procedure. VT was induced by burst stimulation after ligation of the left anterior descending coronary artery, and the termination effects of the optical manipulation, including electrical anti-tachycardia pacing (ATP) and spontaneous recovery, were tested. Among different multisegment optical modes, four repeated illuminations of 1000 ms in duration with 1-second interval at a 20-times intensity threshold on the right ventricle achieved the highest termination rate of 86.14% ± 4.145%, higher than that achieved by ATP and spontaneous termination. We demonstrated that optogenetic-based cardioversion is feasible and effective in vivo, with the underlying mechanism involving the light-triggered, ChR2-induced depolarization of the illuminated myocardium, in turn generating an excitation that disrupts the preexisting reentrant wave front.
Collapse
Affiliation(s)
- Yue Cheng
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People's Republic of China
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
| | - Haitao Li
- Department of Cardiology, Hainan General Hospital, Hainan Affiliated Hospital of Hainan Medical University, Haikou, China
| | - Long Wang
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
- Department of Anesthesiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Jianyi Li
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People's Republic of China
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
| | - Wen Kang
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
- Department of Anesthesiology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Panpan Rao
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People's Republic of China
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
| | - Fang Zhou
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
- Department of Cardiology, Hainan General Hospital, Hainan Affiliated Hospital of Hainan Medical University, Haikou, China
| | - Xi Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People's Republic of China
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
| | - Congxin Huang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People's Republic of China
- Cardiovascular Research Institute, Wuhan University, Wuhan, People's Republic of China
- Hubei Key Laboratory of Cardiology, Wuhan, People's Republic of China
| |
Collapse
|
4
|
The Saga of Defibrillation Testing: When Less Is More. Curr Cardiol Rep 2018; 20:44. [DOI: 10.1007/s11886-018-0987-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
5
|
Garg J, Chaudhary R, Shah N, Palaniswamy C, Bozorgnia B, Nazir T, Natale A, Kutyifa V. Right ventricular apical versus non-apical implantable cardioverter defibrillator lead: A systematic review and meta-analysis. J Electrocardiol 2017; 50:591-597. [DOI: 10.1016/j.jelectrocard.2017.05.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Indexed: 10/19/2022]
|
6
|
Temporal Trends in and Factors Associated With Use of Single- Versus Dual-Coil Implantable Cardioverter-Defibrillator Leads. JACC Clin Electrophysiol 2017; 3:612-619. [DOI: 10.1016/j.jacep.2016.11.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 11/29/2016] [Accepted: 11/29/2016] [Indexed: 11/22/2022]
|
7
|
Amit G, Wang J, Connolly SJ, Glikson M, Hohnloser S, Wright DJ, Brachmann J, Defaye P, Neuzner J, Mabo P, Vanerven L, Vinolas X, O'Hara G, Kautzner J, Appl U, Gadler F, Stein K, Konstantino Y, Healey JS. Apical versus Non-Apical Lead: Is ICD Lead Position Important for Successful Defibrillation? J Cardiovasc Electrophysiol 2016; 27:581-6. [PMID: 26888558 DOI: 10.1111/jce.12952] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2015] [Revised: 12/25/2015] [Accepted: 01/04/2016] [Indexed: 11/27/2022]
Abstract
INTRODUCTION We aim to compare the acute and long-term success of defibrillation between non-apical and apical ICD lead position. METHODS AND RESULTS The position of the ventricular lead was recorded by the implanting physician for 2,475 of 2,500 subjects in the Shockless IMPLant Evaluation (SIMPLE) trial, and subjects were grouped accordingly as non-apical or apical. The success of intra-operative defibrillation testing and of subsequent clinical shocks were compared. Propensity scoring was used to adjust for the impact of differences in baseline variables between these groups. There were 541 leads that were implanted at a non-apical position (21.9%). Patients implanted with a non-apical lead had a higher rate of secondary prevention indication. Non-apical location resulted in a lower mean R-wave amplitude (14.0 vs. 15.2, P < 0.001), lower mean pacing impedance (662 ohm vs. 728 ohm, P < 0.001), and higher mean pacing threshold (0.70 V vs. 0.66 V, P = 0.01). Single-coil leads and cardiac resynchronization devices were used more often in non-apical implants. The success of intra-operative defibrillation was similar between propensity score matched groups (89%). Over a mean follow-up of 3 years, there were no significant differences in the yearly rates of appropriate shock (5.5% vs. 5.4%, P = 0.98), failed appropriate first shock (0.9% vs. 1.0%, P = 0.66), or the composite of failed shock or arrhythmic death (2.8% vs. 2.3% P = 0.35) according to lead location. CONCLUSION We did not detect any reduction in the ICD efficacy at the time of implant or during follow-up in patients receiving a non-apical RV lead.
Collapse
Affiliation(s)
- Guy Amit
- Hamilton Health Sciences, Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Jia Wang
- Hamilton Health Sciences, Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Stuart J Connolly
- Hamilton Health Sciences, Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Michael Glikson
- Leviev Heart Center, Sheba Medical Center, Tel Hashomer, Israel
| | | | | | | | | | | | | | | | | | - Gilles O'Hara
- Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Canada
| | - Josef Kautzner
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Ursula Appl
- Boston Scientific, Minneapolis, Minnesota, USA.,Boston Scientific, Brussels, Belgium
| | | | - Kenneth Stein
- Boston Scientific, Minneapolis, Minnesota, USA.,Boston Scientific, Brussels, Belgium
| | | | - Jeff S Healey
- Hamilton Health Sciences, Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
8
|
Defibrillation Threshold Testing: Who Doesn't Get It? Card Electrophysiol Clin 2016; 4:135-41. [PMID: 26939810 DOI: 10.1016/j.ccep.2012.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Defibrillation testing has been routinely performed as part of the implantable cardioverter-defibrillator (ICD) implantation procedure, and is currently supported by practice guidelines; however, more recently, this practice has been called into question. Such testing is safe, and serious complications are rare. With modern ICD systems, physicians will rarely encounter a patient in whom defibrillation will fail. This article reviews the literature regarding the utility, necessity, complications, and cost of routine operative and follow-up defibrillation testing, and, it is hoped, clarifies the issue of "Who doesn't get it?"
Collapse
|
9
|
Kaye GC, Eng LK, Hunt BJ, Dauber KM, Hill J, Gould PA. A Comparison of Right Ventricular Non-apical Defibrillator Lead Position with Traditional Right Ventricular Apical Position: A Single Centre Experience. Heart Lung Circ 2015; 24:179-84. [DOI: 10.1016/j.hlc.2014.08.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Revised: 08/08/2014] [Accepted: 08/19/2014] [Indexed: 11/25/2022]
|
10
|
Abstract
In patients with advanced systolic heart failure and mechanical dyssynchrony, cardiac resynchronization therapy (CRT) is an effective means of improving symptoms and reducing mortality. There are now several recognized approaches to optimize CRT. Imaging modalities can assist with identifying the myocardium with the latest mechanical activation for targeted left ventricular lead implantation. Device programming can be tailored to maximize biventricular pacing, and thereby is its benefit. Cardiac imaging has shown that atrioventricular and interventricular intervals can be adjusted to further reduce dyssynchrony. We review these various approaches that maximize the benefit derived from CRT.
Collapse
|
11
|
Daubert JC, Saxon L, Adamson PB, Auricchio A, Berger RD, Beshai JF, Breithard O, Brignole M, Cleland J, DeLurgio DB, Dickstein K, Exner DV, Gold M, Grimm RA, Hayes DL, Israel C, Leclercq C, Linde C, Lindenfeld J, Merkely B, Mont L, Murgatroyd F, Prinzen F, Saba SF, Shinbane JS, Singh J, Tang AS, Vardas PE, Wilkoff BL, Zamorano JL, Anand I, Blomström-Lundqvist C, Boehmer JP, Calkins H, Cazeau S, Delgado V, Estes NAM, Haines D, Kusumoto F, Leyva P, Ruschitzka F, Stevenson LW, Torp-Pedersen CT. 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Europace 2013; 14:1236-86. [PMID: 22930717 DOI: 10.1093/europace/eus222] [Citation(s) in RCA: 201] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
12
|
|
13
|
Daubert JC, Saxon L, Adamson PB, Auricchio A, Berger RD, Beshai JF, Breithard O, Brignole M, Cleland J, Delurgio DB, Dickstein K, Exner DV, Gold M, Grimm RA, Hayes DL, Israel C, Leclercq C, Linde C, Lindenfeld J, Merkely B, Mont L, Murgatroyd F, Prinzen F, Saba SF, Shinbane JS, Singh J, Tang AS, Vardas PE, Wilkoff BL, Zamorano JL. 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Heart Rhythm 2012; 9:1524-76. [PMID: 22939223 DOI: 10.1016/j.hrthm.2012.07.025] [Citation(s) in RCA: 186] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2012] [Indexed: 11/30/2022]
|
14
|
Kroll MW. To the Editor: End of the apex era? Heart Rhythm 2011; 8:e9-10. [DOI: 10.1016/j.hrthm.2011.01.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2010] [Indexed: 10/18/2022]
|
15
|
Reynolds CR, Gold MR. To the Editor: Optimizing right ventricular lead position for defibrillation. Heart Rhythm 2011; 9:e26-7. [PMID: 21255677 DOI: 10.1016/j.hrthm.2011.01.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2011] [Indexed: 11/18/2022]
|