1
|
Burke MC, Aasbo JD, El-Chami MF, Weiss R, Dinerman J, Hanon S, Kalahasty G, Bass E, Gold MR. 1-Year Prospective Evaluation of Clinical Outcomes and Shocks: The Subcutaneous ICD Post Approval Study. JACC Clin Electrophysiol 2020; 6:1537-1550. [PMID: 33213814 DOI: 10.1016/j.jacep.2020.05.036] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 05/24/2020] [Accepted: 05/26/2020] [Indexed: 11/24/2022]
Abstract
OBJECTIVES This study evaluated spontaneous arrhythmias and clinical outcomes in the S-ICD System PAS (Subcutaneous Implantable Cardioverter-Defibrillator Post Approval Study) cohort. BACKGROUND The U.S. S-ICD PAS trial patient population more closely resembles transvenous ICD cohorts than earlier studies, which included many patients with little structural heart disease and few comorbidities. Early outcomes and low peri-operative complication rates were demonstrated in the S-ICD PAS cohort, but there are no data detailing spontaneous arrhythmias and clinical outcomes. METHODS The S-ICD PAS prospective registry included 1,637 de novo patients from 86 U.S. centers. Descriptive statistics, Kaplan-Meier time to event, and multivariate logistic regression were performed using data out to 365 days. RESULTS Patients (68.5% men; mean ejection fraction of 32.0%; 42.9% ischemic; 13.4% on dialysis) underwent implantation for primary (76.6%) or secondary prevention indication. The complication-free rate was 92.5%. The appropriate shock (AS) rate was 5.3%. A total of 395 ventricular tachycardia (VT) or fibrillation (VF) episodes were appropriately sensed, with 131 (33.2%) self-terminating. First and final shock efficacy (up to 5 shocks) for the 127 discrete AS episodes were 91.3% and 100.0%, respectively. Discrete AS episodes included 67 monomorphic VT (MVT) and 60 polymorphic VT (PVT)/VF, with first shock efficacy of 95.2% and 86.7%, respectively. There were 19 storm events in 18 subjects, with 84.2% conversion success. Storm episodes were more likely PVT/VF (98 of 137). CONCLUSIONS In the first year after implantation, a predominantly primary prevention population with low ejection fraction demonstrated a high complication-free rate and spontaneous event shock efficacy for MVT and PVT/VF arrhythmias at rapid ventricular rates. (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study [S-ICD PAS; NCT01736618).
Collapse
Affiliation(s)
| | - Johan D Aasbo
- Department of Cardiac Electrophysiology, Baptist Health Lexington, Lexington, Kentucky, USA
| | - Mikhael F El-Chami
- Department of Medicine, Emory University Hospital, Atlanta, Georgia, USA
| | - Raul Weiss
- Department of Medicine, Ohio State University, Columbus, Ohio, USA
| | - Jay Dinerman
- Heart Center Research, LLC, Huntsville, Alabama, USA
| | - Sam Hanon
- Department of Medicine, Beth Israel Medical Center, New York, New York, USA
| | - Gauthem Kalahasty
- Department of Internal Medicine, Virginia Commonwealth University Health System, Richmond, Virginia, USA
| | - Eric Bass
- NAMSA (Biostatistics), Minneapolis, Minnesota, USA
| | - Michael R Gold
- Department of Medicine, Medical University of South Carolina, Charleston, South Carolina, USA.
| |
Collapse
|
2
|
Progressive implantable cardioverter-defibrillator therapies for ventricular tachycardia: The efficacy and safety of multiple bursts, ramps, and low-energy shocks. Heart Rhythm 2020; 17:2072-2077. [PMID: 32739474 DOI: 10.1016/j.hrthm.2020.07.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 07/16/2020] [Accepted: 07/22/2020] [Indexed: 11/24/2022]
Abstract
BACKGROUND The Heart Rhythm Society, the European Heart Rhythm Association, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society expert consensus statement on optimal implantable cardioverter-defibrillator programming recommends burst antitachycardia pacing (ATP) for the treatment of ventricular tachycardia (VT) up to high rates. The number of bursts is not specified, and treatment by ramps or low-energy shocks is not recommended. OBJECTIVES We investigated the efficacy and safety of progressive therapies for VTs between 150 and 200 beats/min. After 3 failed bursts, we compared 3 ramps vs 3 bursts followed by a low-energy shock vs high-energy shock. METHODS Using remote monitoring, we included monomorphic VT episodes treated with ≥1 burst. RESULTS A total of 1126 VT episodes were included. A single burst was as likely to terminate VT between 150 and 200 beats/min as VT between 200 and 230 beats/min (63% vs 64%; P=.41), but was more likely to accelerate the latter (3.2% vs 0.25%; P<.01). For VT <200 beats/min, the likelihood of ATP success increased progressively (73% with 2 bursts, 78% with 3 bursts). Three additional bursts further increased VT termination to 89%, similar to the success rate with 3 additional ramps (88%; P=.17). Programming 6 bursts is associated with the probability of acceleration requiring shock of 6.6%. A low-energy first shock was less successful than a high-energy shock (66% vs 86%; P<.01) and more likely to accelerate VT (17% vs 0%; P<.01). CONCLUSION Programming up to 6 burst ATP therapies for VTs 150-200 beats/min can avoid implantable cardioverter-defibrillator shocks in most patients. Ramp ATP after failed bursts were similarly effective. Low-energy shocks are less effective and more arrhythmogenic than high-energy shocks.
Collapse
|
3
|
Bögeholz N, Willy K, Niehues P, Rath B, Dechering DG, Frommeyer G, Kochhäuser S, Löher A, Köbe J, Reinke F, Eckardt L. Spotlight on S-ICD™ therapy: 10 years of clinical experience and innovation. Europace 2019; 21:1001-1012. [DOI: 10.1093/europace/euz029] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 02/09/2019] [Indexed: 11/14/2022] Open
Abstract
Abstract
Subcutaneous ICD (S-ICD™) therapy has been established in initial clinical trials and current international guideline recommendations for patients without demand for pacing, cardiac resynchronization, or antitachycardia pacing. The promising experience in ‘ideal’ S-ICD™ candidates increasingly encourages physicians to provide the benefits of S-ICD™ therapy to patients in clinical constellations beyond ‘classical’ indications of S-ICD™ therapy, which has led to a broadening of S-ICD™ indications in many centres. However, the decision for S-ICD™ implantation is still not covered by controlled randomized trials but rather relies on patient series or observational studies. Thus, this review intends to give a contemporary update on available empirical evidence data and technical advancements of S-ICD™ technology and sheds a spotlight on S-ICD™ therapy in recently discovered fields of indication beyond ideal preconditions. We discuss the eligibility for S-ICD™ therapy in Brugada syndrome as an example for an adverse and dynamic electrocardiographic pattern that challenges the S-ICD™ sensing and detection algorithms. Besides, the S-ICD™ performance and defibrillation efficacy in conditions of adverse structural remodelling as exemplified for hypertrophic cardiomyopathy is discussed. In addition, we review recent data on potential device interactions between S-ICD™ systems and other implantable cardio-active systems (e.g. pacemakers) including specific recommendations, how these could be prevented. Finally, we evaluate limitations of S-ICD™ therapy in adverse patient constitutions, like distinct obesity, and present contemporary strategies to assure proper S-ICD™ performance in these patients. Overall, the S-ICD™ performance is promising even for many patients, who may not be ‘classical’ candidates for this technology.
Collapse
Affiliation(s)
- Nils Bögeholz
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Kevin Willy
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Philipp Niehues
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Benjamin Rath
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Dirk G Dechering
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Gerrit Frommeyer
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Simon Kochhäuser
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Andreas Löher
- Department of Cardiothoracic Surgery, University Hospital of Muenster, Muenster, Germany
| | - Julia Köbe
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Florian Reinke
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| | - Lars Eckardt
- Division of Electrophysiology, Department of Cardiology and Angiology, University Hospital of Muenster, Muenster, Germany
| |
Collapse
|
4
|
Kanagasundram AN, John RM, Stevenson WG. Ventricular tachycardia induced by antitachycardia pacing for ventricular tachycardia: Not so pain-free? Heart Rhythm 2018; 16:551-552. [PMID: 30465904 DOI: 10.1016/j.hrthm.2018.11.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2018] [Indexed: 11/26/2022]
Affiliation(s)
- Arvindh N Kanagasundram
- Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Roy M John
- Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee
| | - William G Stevenson
- Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee.
| |
Collapse
|
5
|
Frankel DS, Burke MC, Callans DJ, Stivland TM, Duffy E, Epstein AE. Impact of Body Mass Index on Safety and Efficacy of the Subcutaneous Implantable Cardioverter-Defibrillator. JACC Clin Electrophysiol 2018; 4:652-659. [DOI: 10.1016/j.jacep.2017.11.019] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 11/27/2017] [Accepted: 11/30/2017] [Indexed: 11/26/2022]
|
6
|
Burri H, Moretti F, Meyer P. Low-energy cardioversion of ventricular tachycardia: When less is more. Indian Pacing Electrophysiol J 2017; 17:44-47. [PMID: 29072992 PMCID: PMC5405749 DOI: 10.1016/j.ipej.2017.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Accepted: 02/13/2017] [Indexed: 11/23/2022] Open
Abstract
Herein we report the case of a patient who was admitted in ventricular tachycardia after having received multiple ineffective (and sometimes pro-arrhythmic) high-energy internal shocks from his ICD and who was finally successfully treated by a commanded low-energy internal cardioversion of 0.6 J. This article revisits the use of low-energy shocks and discusses their electrophysiogical mechanisms and clinical implications.
Collapse
Affiliation(s)
- Haran Burri
- Cardiology Department, Geneva University Hospital, Geneva, Switzerland.
| | - Francesco Moretti
- Cardiology Department, Geneva University Hospital, Geneva, Switzerland
| | - Philippe Meyer
- Cardiology Department, Geneva University Hospital, Geneva, Switzerland
| |
Collapse
|
7
|
Arenal A, Proclemer A, Kloppe A, Lunati M, Martìnez Ferrer JB, Hersi A, Gulaj M, Wijffels MCEF, Santi E, Manotta L, Mangoni L, Gasparini M. Different impact of long-detection interval and anti-tachycardia pacing in reducing unnecessary shocks: data from the ADVANCE III trial. Europace 2016; 18:1719-1725. [PMID: 27485577 PMCID: PMC5408998 DOI: 10.1093/europace/euw032] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Accepted: 02/02/2016] [Indexed: 11/14/2022] Open
Abstract
AIMS A long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial. METHODS AND RESULTS A total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections). A total of 346 fast ventricular tachycardias (FVT) were detected in 169 patients: 208 in 105 patients with SDI and 138 in 64 patients with LDI. Setting LDI determined a significant reduction in appropriate but unnecessary therapies [208 in SDI vs. 138 in LDI; incidence rate ratio (IRR): 0.61 (95% CI 0.45-0.83), P = 0.002]. Anti-tachycardia pacing determined another 52% reduction in unnecessary shocks [208 in SDI with hypothetical shock-only programming vs. 66 in LDI with ATP; IRR: 0.37 (95% CI 0.25-0.53, P < 0.001)]. The efficacy of ATP in terminating FVT was 63% in SDI and 52% in LDI (P = 0.022). No difference in the safety profile (acceleration/degeneration and death/cardiovascular hospitalizations) was observed between the two groups. CONCLUSION The combination of LDI and ATP during charging is extremely effective and significantly reduces appropriate but unnecessary therapies. The use of LDI alone yielded a 39% reduction in appropriate but unnecessary therapies; ATP on top of LDI determined another 52% reduction in unnecessary shocks. The strategy of associating ATP and LDI could be considered in the majority of ICD recipients.
Collapse
Affiliation(s)
- Angel Arenal
- Hospital General Universitario Gregorio Marañón, C/Dr. Esquerdo 46, 28007 Madrid, Spain
| | - Alessandro Proclemer
- Azienda Ospedaliero Universitaria S. Maria della Misericordia, Piazzale S. Maria della Misericordia, 33100 Udine, Italy
| | - Axel Kloppe
- Medizinische Klinik II, Kardiologie und Angiologie, Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil, Ruhr-Universität-Bochum, Bochum, Germany
| | - Maurizio Lunati
- Azienda Ospedaliera Niguarda Ca' Granda, Piazza Ospedale Maggiore, 3-20162 Milano, Italy
| | | | - Ahmad Hersi
- College of Medicine, King Saud University, 11472 Riyadh, Saudi Arabia
| | | | | | - Elisabetta Santi
- MEDTRONIC Clinical Research Center, Via Aurelia 475/477-00165, Roma, Italy
| | - Laura Manotta
- MEDTRONIC Clinical Research Center, Via Varesina, 162-20156 Milano, Italy
| | - Lorenza Mangoni
- MEDTRONIC Clinical Research Center, Via Aurelia 475/477-00165, Roma, Italy
| | | |
Collapse
|
8
|
Digital monitoring and care: Virtual medicine. Trends Cardiovasc Med 2016; 26:722-730. [PMID: 27373351 DOI: 10.1016/j.tcm.2016.05.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 05/13/2016] [Accepted: 05/19/2016] [Indexed: 01/29/2023]
Abstract
Remote digital health monitoring technologies can be synergistically organized to create a virtual medical system providing more continuous care centered on the patient rather than the bricks and mortar medical complex. Utilization of the digitalized patient health monitoring can facilitate diagnosis, treatment plans, physician-patient interaction, and accelerate the progress of medical research, education, and training. The field of cardiac electrophysiology has been an early adopter of this shift in care and serves as a paradigm applicable to all areas of medicine. The overall impact of this remote virtual care model on the quality of medical care and patient experience requires greater study, as well as vigilance as to the differences between technology and care in order to preserve the intangible and immeasurable factors that bring humanity to the art and science of medicine.
Collapse
|
9
|
Bertomeu-González V, Moreno-Arribas J, Castillo-Castillo J, Martínez-Ferrer J, Viñolas X, Rodríguez A, Díaz-Infante E, Fernández-Lozano I, Alzueta J, Fontenla A. Etiology and Programming Effects on Shock Efficacy in ICD Recipients. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2015; 39:73-80. [PMID: 26450114 DOI: 10.1111/pace.12765] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2015] [Revised: 08/20/2015] [Accepted: 09/24/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND We sought to assess the efficacy of high-energy shocks to restore rhythm and predictors of success in patients with sustained ventricular arrhythmias and implantable cardioverter defibrillator (ICD). METHODS AND RESULTS Data from 162 patients included in the UMBRELLA study that experienced one or more episodes of ventricular tachycardia (VT) for which ICD shocks of at least 30 Joules were delivered (appropriate high-energy shocks) were analyzed. In total, 456 ventricular arrhythmia episodes were registered. Forty four episodes (9.6%) from 39 patients (24%) had at least one ineffective high-energy shock delivered. Hypertrophic cardiomyopathy was more frequent among patients with unsuccessful shocks (10.3% vs 2.4%). Patients with ineffective shocks had higher proportion of sustained monomorphic ventricular arrhythmias (86.4%; the other 13.6% were sustained polymorphic and ventricular fibrillation [VF]) compared with patients with all their shocks effective (62.9%, P = 0.02). No statistical differences were found between groups in time from detection to the high-energy shock delivery, in tachycardia cycle length, or in antitachycardia pacing, but patients with ineffective high-energy shocks had higher proportion of previously ineffective low-energy shock (9.1% vs 0.5%, P = 0.01). CONCLUSION We found a substantial rate of ineffective high-energy shocks for the treatment of VT or VF in patients with ICD. High-energy shock efficacy seems to be reduced by hypertrophic cardiomyopathy and by the administration of previous low-energy shocks.
Collapse
Affiliation(s)
| | - José Moreno-Arribas
- Hospital Universitario de San Juan, Universidad Miguel Hernandez, Alicante, Spain
| | | | | | | | - Aníbal Rodríguez
- Hospital Universitario de Canarias, Santa Cruz de Tenerife, Spain
| | | | | | - Javier Alzueta
- Hospital Clínico Universitario Virgen de la Victoria, Málaga, Spain
| | | |
Collapse
|
10
|
Kramer DB, Mitchell SL, Monteiro J, Jones PW, Normand SL, Hayes DL, Reynolds MR. Patient Activity and Survival Following Implantable Cardioverter-Defibrillator Implantation: The ALTITUDE Activity Study. J Am Heart Assoc 2015; 4:JAHA.115.001775. [PMID: 25979902 PMCID: PMC4599410 DOI: 10.1161/jaha.115.001775] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Background Physical activity data are collected automatically by implantable cardioverter-defibrillators (ICDs). Though these data potentially provide a quantifiable and easily accessible measure of functional status, its relationship with survival has not been well studied. Methods and Results Patients enrolled in the Boston Scientific LATITUDE remote monitoring system from 2008 to 2012 with ICDs were eligible. Remote monitoring data were used to calculate mean daily activity at baseline (30 to 60 days after implantation), and longitudinally. Cox regression was used to examine the association between survival and increments of 30 minutes/day in both (1) mean baseline activity and (2) time-varying activity, with both adjusted for demographic and device characteristics. A total of 98 437 patients were followed for a median of 2.2 years (mean age of 67.7±13.1 years; 71.7% male). Mean baseline daily activity was 107.5±66.2 minutes/day. The proportion of patients surviving after 4 years was significantly higher among those in the most versus least active quintile of mean baseline activity (90.5% vs. 50.0%; log-rank P value, <0.001). Lower mean baseline activity (i.e., incremental difference of 30-minutes/day) was independently associated with a higher risk of death (adjusted hazard ratio [AHR], 1.44; 95% confidence interval [CI], 1.427 to 1.462). Time-varying activity was similarly associated with a higher risk of death (AHR, 1.48; 95% CI, 1.451 to 1.508), indicating that a patient having 30 minutes per day less activity in a given month has a 48% increased hazard for death when compared to a similar patient in the same month. Conclusions Patient activity measured by ICDs strongly correlates with survival following ICD implantation.
Collapse
Affiliation(s)
- Daniel B Kramer
- Beth Israel Deaconess Medical Center, Boston, MA (D.B.K., S.L.M.) Harvard Medical School, Boston, MA (D.B.K., S.L.M., S.L.N.) Hebrew SeniorLife Institute for Aging Research, Boston, MA (D.B.K., S.L.M.)
| | - Susan L Mitchell
- Beth Israel Deaconess Medical Center, Boston, MA (D.B.K., S.L.M.) Harvard Medical School, Boston, MA (D.B.K., S.L.M., S.L.N.) Hebrew SeniorLife Institute for Aging Research, Boston, MA (D.B.K., S.L.M.)
| | - Joao Monteiro
- North American Science Associates, Inc, Minneapolis, MN (J.M.)
| | | | - Sharon-Lise Normand
- Harvard Medical School, Boston, MA (D.B.K., S.L.M., S.L.N.) Harvard School of Public Health, Boston, MA (S.L.N.)
| | | | - Matthew R Reynolds
- Lahey Clinic, Burlington, MA (M.R.R.) Harvard Clinical Research Institute, Boston, MA (M.R.R.)
| |
Collapse
|
11
|
Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator. J Am Coll Cardiol 2015; 65:1605-1615. [DOI: 10.1016/j.jacc.2015.02.047] [Citation(s) in RCA: 393] [Impact Index Per Article: 43.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 02/01/2015] [Accepted: 02/16/2015] [Indexed: 11/20/2022]
|
12
|
Guédon-Moreau L, Mabo P, Kacet S. Current clinical evidence for remote patient management. ACTA ACUST UNITED AC 2013; 15 Suppl 1:i6-i10. [DOI: 10.1093/europace/eut119] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|