1
|
Chen X, Dong J. Stylet-driven leads compared with lumenless leads for left bundle branch area pacing: a systematic review and meta-analysis. BMC Cardiovasc Disord 2024; 24:598. [PMID: 39462327 PMCID: PMC11514867 DOI: 10.1186/s12872-024-04273-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 10/17/2024] [Indexed: 10/29/2024] Open
Abstract
OBJECTIVE Left bundle branch area pacing (LBBAP) is a novel physiological pacing method for treating left ventricular dyssynchrony. LBBAP is often delivered using lumenless leads (LLL). However, recent studies have also reported the use of style-driven leads (SDL). This study is the first systematic review comparing the outcomes of LBBAP with SDL vs. LLL. METHODS The review and meta-analysis included all available comparative studies published on Embase, PubMed, Web of Science, CENTRAL, and Scopus up to 6th March 2024. RESULTS Eight observational studies were included in the review. Meta-analysis showed that success rates of LBBAP performed with LLL and SDL were comparable (OR: 1.72 95% CI: 0.94, 3.17 I2 = 38%). Duration of implantation and total procedural duration were significantly lower in LBBAP performed with SDL. The pacing threshold was significantly higher, while pacing impedance was significantly lower in the SDL compared to the LLL group. Pacing QRS interval, R-wave amplitude, and stimulus to peak left ventricular activation time were similar in the two groups. Intra-operative and post-operative dislodgement were significantly higher in the SDL group, but no difference was noted in intra-operative perforation and pneumothorax risk. CONCLUSION Limited evidence from observational studies with inherent selection bias shows that success rates for LBBAP may not differ between SDL and LLL. While implantation of SDL may be significantly faster, it carries a higher risk of lead dislodgement. Both SDL and LLL are associated with comparable pacing characteristics except for reduced pacing impedance with SDL.
Collapse
Affiliation(s)
- Xuezhi Chen
- Department of Cardiology, Capital Medical University Affiliated Anzhen Hospital, No.2 of Anzhen Road, Chaoyang District, 100029, Beijing, People's Republic of China
- Department of Cardiology, Peking University International Hospital, Beijing, China
| | - Jianzeng Dong
- Department of Cardiology, Capital Medical University Affiliated Anzhen Hospital, No.2 of Anzhen Road, Chaoyang District, 100029, Beijing, People's Republic of China.
| |
Collapse
|
2
|
Cano Ó, Pooter JD, Zanon F. Stylet-driven Leads or Lumenless Leads for Conduction System Pacing. Arrhythm Electrophysiol Rev 2024; 13:e14. [PMID: 39385772 PMCID: PMC11462514 DOI: 10.15420/aer.2024.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 05/30/2024] [Indexed: 10/12/2024] Open
Abstract
Stylet-driven leads have been recently introduced for conduction system pacing, while most of the previous experience has been obtained with lumenless leads. Design and structural characteristics of both lead types are significantly different, resulting in different implant techniques and independent learning curves. Lead performance appears to be comparable, whereas data on direct comparison of clinical outcomes are scarce. Currently, there are no specific clinical scenarios favouring the use of one lead type over another and the decision should rely on the individual experience of the implanter.
Collapse
Affiliation(s)
- Óscar Cano
- Unidad de Arritmias, Hospital Universitario y Politécnico La FeValencia, Spain
- Centro de Investigaciones Biomédicas en Red en Enfermedades Cardiovasculares (CIBERCV)Madrid, Spain
| | - Jan De Pooter
- Heart Centre, University Hospital GhentGhent, Belgium
| | - Francesco Zanon
- Department of Cardiology, Santa Maria della Misericordia General HospitalRovigo Italy
| |
Collapse
|
3
|
Ju C, Zhou Y, Cheng K, Xie X. Observational study of left bundle branch area pacing: implantation of the solia S lead using the selectra 3D sheath at an inclined angle. BMC Cardiovasc Disord 2024; 24:446. [PMID: 39182047 PMCID: PMC11344286 DOI: 10.1186/s12872-024-04107-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 08/08/2024] [Indexed: 08/27/2024] Open
Abstract
BACKGROUND Left Bundle Branch Area Pacing (LBBaP) is a cardiac pacing technique designed to mimic the natural conduction system of the heart. Traditional right ventricular apical pacing has been associated with increased risks of heart failure and atrial fibrillation. This study investigates the stability and safety of LBBaP using the Selectra 3D sheath (Biotronik) with an inclined angle for implanting the Solia S lead (Biotronik, SE & Co, KG). METHODS A single-center retrospective study was conducted on 25 patients who underwent LBBaP implantation using the Selectra 3D sheath at our hospital. The procedure involved inserting the Solia S lead into the interventricular septum at an inclined angle. Surgical and postoperative data were collected, including the success rate, depth and angle of electrode insertion, complications, and follow-up data. RESULTS The success rate of LBBaP implantation was 92%. The length of electrode insertion into the interventricular septum ranged from 12 to 23.0 mm, with an average of 18.1 ± 3.08 mm. The angle formed between the electrode and the septum ranged from 0° to 57.3°, with an average of 35.14°±14.31°. During the 3-month follow-up period, pacing parameters remained stable, and no complications were reported. CONCLUSIONS LBBaP implantation using the Selectra 3D sheath with an inclined angle for the Solia S implantation demonstrates stability and safety. The procedure boasts a high success rate and offers an effective option for LBBaP implantation.
Collapse
Affiliation(s)
- Changlin Ju
- Department of Cardiology, The First Affiliated Hospital of Wannan Medical College, Wuhu, 241000, Anhui, China
| | - Yu Zhou
- Department of Emergency, The First Affiliated Hospital of Wannan Medical College, Wuhu, 241000, Anhui, China
| | - Keng Cheng
- Department of Cardiology, The First Affiliated Hospital of Wannan Medical College, Wuhu, 241000, Anhui, China
| | - Xiangrong Xie
- Department of Cardiology, The First Affiliated Hospital of Wannan Medical College, Wuhu, 241000, Anhui, China.
| |
Collapse
|
4
|
Ghosh A, Ka MA, Sriram CS, Pandurangi UM. Caveats related to conduction system pacing utilizing a proprietary deflectable mapping catheter with a stylet-driven lead. J Interv Card Electrophysiol 2024; 67:759-771. [PMID: 37840120 DOI: 10.1007/s10840-023-01637-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 09/01/2023] [Indexed: 10/17/2023]
Abstract
BACKGROUND Hitherto, lumen less leads (LLLs) were routinely utilized for conduction system pacing (CSP). We report the largest experience using stylet-driven leads (SDLs) with a deflectable mapping catheter for CSP. METHODS Patients were prospectively and sequentially enrolled for CSP with SDL between June, 2021 and November, 2022 to (i) a novel deflectable mapping catheter (AgilisHisProTM, Abbott) (Group A) or (ii) a fixed curve sheath (Selectra3D, Biotronik) (Group B) in a 1:1 non-randomized fashion. The primary aim was to evaluate safety, feasibility, and efficacy of the CSP using SDL and deflectable mapping catheter (Group A) while reporting procedural success and intermediate-term follow-up. RESULTS Seventy-nine patients (59.4%M, mean age 67.2+/-10.6 years) were allocated to either (i) Group A (n = 40) or (ii) Group B (n = 39). In Group A (n = 40, 50% M, mean age 67.2+/-9.5 years, follow-up 210.7 + 25.1days), His bundle pacing (HBP) was the default strategy with left bundle branch area pacing (LBBaP) for bailout. Procedural success with HBP was feasible in 17/40 (42.5%) patients with remaining 23/40 (57.5%) needing LBBaP bailout. After initial learning curve, a manual septal curve was introduced to successfully aid LBBaP in 6/23 (26.1%) cases. Procedural and follow-up parameters did not differ significantly in HBP vs. LBBaP. Head-to-head comparison was not performed between the groups owing to different default protocols (HBP-Group A, Discretionary-Group B). CONCLUSIONS Use of SDL with single-curve deflectable mapping catheter was safe, feasible and yielded moderate procedural success with HBP and frequently needed a LBBaP bailout strategy. In approximately one-fourth of the latter, an out-of-plane manual septal curve was needed to optimize LBBaP.
Collapse
Affiliation(s)
- Anindya Ghosh
- Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, 4-A, Dr. JJ Nagar, Mogappair, Chennai, Tamil Nadu, India
| | - Mohamed Akram Ka
- Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, 4-A, Dr. JJ Nagar, Mogappair, Chennai, Tamil Nadu, India
| | - Chenni S Sriram
- Division of Cardiology, Sub-section of Electrophysiology, Children's Hospital of Michigan and Detroit Medical Center, Detroit, MI, USA
| | - Ulhas M Pandurangi
- Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, 4-A, Dr. JJ Nagar, Mogappair, Chennai, Tamil Nadu, India.
| |
Collapse
|
5
|
De Pooter J, Bulava A, Gras D, Timmer S, Chin-Pang Chan G, Clementy N, Pathak RK, Healy S, Lüsebrink U, Zanon F. Utility of a guiding catheter for conduction system pacing: An early multicenter experience. Heart Rhythm O2 2024; 5:8-16. [PMID: 38312208 PMCID: PMC10837172 DOI: 10.1016/j.hroo.2023.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2024] Open
Abstract
Background Conduction system pacing (CSP), either as His bundle pacing (HBP) or as left bundle branch area pacing (LBBAP), may be superior to right ventricular apical or septal pacing. Objective The study sought to present acute results for a new guiding catheter (Biotronik Selectra 3D) designed for CSP implantations of a retractable screw-in lead (Biotronik Solia S). Methods The primary endpoint of the prospective, international nonrandomized BIO|MASTER.Selectra 3D study was freedom from catheter-related serious adverse device effects (SADEs) within 1 week of lead implantation. Results Of 157 enrolled patients, CSP was achieved in 147 (93.6%) patients. No SADEs occurred within 7 days. LBBAP was achieved in 82 patients (45 as crossover from an HBP attempt) and HBP in 65 (44.2%) patients. In centers considering both HBP and LBBAP, the CSP implantation success approached 99%. Successful CSP implantations lasted on average ∼50 minutes (fluoroscopy ∼6 minutes). Most procedures (87.9%) needed only 1 catheter, even after switch from HBP to LBBAP. The catheter's handling was rated largely positive. In patients without bundle branch block, mean QRS duration increased from 106 ms (intrinsic) to 122 ms (CSP) (P = .001). In patients with bundle branch block, mean QRS duration decreased from 151 ms (intrinsic) to 137 ms (CSP) (P = .004). Conclusion The Selectra 3D catheter is a valuable tool for HBP and LBBAP implantations of the stylet-supported pacemaker leads. When implanters considered both HBP and LBBAP, the success rate was ∼99%. Flexibility to change between different approaches may be advisable in heterogeneous and challenging areas, such as CSP implantations.
Collapse
Affiliation(s)
| | - Alan Bulava
- České Budějovice Hospital, Faculty of Health and Social Sciences, Cardiology, University of South Bohemia, České Budějovice, Czech Republic
| | - Daniel Gras
- Hôpital Privé du Confluent, Cardiology, Nantes, France
| | - Stefan Timmer
- Noordwest Ziekenhuisgroep, Cardiology, Alkmaar, the Netherlands
| | | | - Nicolas Clementy
- Centre Hospitalier Régional Universitaire de Tours, Cardiology, Chambray-lès-Tours, France
| | - Rajeev K Pathak
- Canberra Heart Rhythm, Australian National University, Cardiology, Garran, Australian Capital Territory, Australia
| | - Stewart Healy
- Monash Medical Centre, Cardiology, Melbourne, Victoria, Australia
| | - Ulrich Lüsebrink
- Universitätsklinikum Gießen und Marburg, Kardiologie, Marburg, Germany
| | - Francesco Zanon
- Santa Maria della Misericordia, Arrhythmia and Electrophysiology Unit, Rovigo, Italy
| |
Collapse
|
6
|
Daniëls F, Adiyaman A, Aarnink KM, Oosterwerff FJ, Verbakel JRA, Ghani A, Smit JJJ, Kanters MA, Delnoy PPHM, Elvan A. The Zwolle experience with left bundle branch area pacing using stylet-driven active fixation leads. Clin Res Cardiol 2023; 112:1738-1747. [PMID: 35716195 PMCID: PMC9206214 DOI: 10.1007/s00392-022-02048-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 05/30/2022] [Indexed: 11/29/2022]
Abstract
AIMS Left bundle branch area pacing (LBBAP) is a novel physiological pacing modality and is regarded as a viable alternative to His bundle pacing. LBBAP has mostly been performed with the lumen-less permanent pacing lead (SelectSecure™ Model 3830, Medtronic, Inc.) with a fixed helix. The aim of this study was to compare the non-stylet driven lumen-less lead (LLL) (Medtronic 3830) with a standard stylet-driven active fixation lead (SDL) (Tendril™ STS Model 2088TC-38, Abbott Laboratories) in terms of lead parameters, procedural success and complication rates. METHODS Patients receiving a LBBA pacemaker in the Isala Hospital, The Netherlands, were prospectively enrolled. The majority received a standard right ventricular (RV) lead as backup, the implanter chose between LLL and SDL for the LBBAP lead. RESULTS The study included 94 patients with a mean follow-up of 30 weeks. 30/31 LLL procedures were successful, compared with 62/63 in the SDL group. Including the participants that lost LBBAP during follow-up resulted in success rates of 90.3% for LLL versus 96.8% for SDL, P = 0.199. Mean number of deployments was significantly lower in the SDL group compared with the LLL group (2 ± 2.3 versus 4 ± 3.4, P = 0.005), implantation and procedural times were comparable. Pacing thresholds were low and remained low in both groups (at last follow-up 0.8 ± 0.30 V for LLL versus 0.6 ± 0.20 V for SDL). Complication rates did not differ significantly between both groups, P = 0.805. CONCLUSION LBBAP using SDL is feasible and has comparable success rates with lower number of deployments of the active fixation screw.
Collapse
Affiliation(s)
- F Daniëls
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - A Adiyaman
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - K M Aarnink
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - F J Oosterwerff
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - J R A Verbakel
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - A Ghani
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - J J J Smit
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - M A Kanters
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - P P H M Delnoy
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | - A Elvan
- Department of Cardiology, Isala Heart Center, Dr. van Heesweg 2, 8025 AB, Zwolle, The Netherlands.
| |
Collapse
|
7
|
Padala SK, Ellenbogen KA. Pacing of Specialized Conduction System. Cardiol Clin 2023; 41:463-489. [PMID: 37321695 DOI: 10.1016/j.ccl.2023.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Right ventricular pacing for bradycardia remains the mainstay of pacing therapy. Chronic right ventricular pacing may lead to pacing-induced cardiomyopathy. We focus on the anatomy of the conduction system and the clinical feasibility of pacing the His bundle and/or left bundle conduction system. We review the hemodynamics of conduction system pacing, the techniques to capture the conduction system and the electrocardiogram and pacing definitions of conduction system capture. Clinical studies of conduction system pacing in the setting of atrioventricular block and after AV junction ablation are reviewed and the evolving role of conduction system pacing is compared with biventricular pacing.
Collapse
Affiliation(s)
- Santosh K Padala
- Department of Cardiac Electrophysiology, Virginia Commonwealth University, Gateway Building, 3 Road Floor, 3-216, 1200 East Marshall Street, Richmond, VA, USA
| | - Kenneth A Ellenbogen
- Department of Cardiac Electrophysiology, Virginia Commonwealth University, Gateway Building, 3 Road Floor, 3-216, 1200 East Marshall Street, Richmond, VA, USA.
| |
Collapse
|
8
|
Physiologic Pacing Targeting the His Bundle and Left Bundle Branch: a Review of the Literature. Curr Cardiol Rep 2022; 24:959-978. [PMID: 35678938 DOI: 10.1007/s11886-022-01723-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/18/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE OF REVIEW Conduction system pacing (CSP) has emerged as a means to preserve or restore physiological ventricular activation via pacing at the His bundle or at more distal targets in the conduction system, including the left bundle branch area. This review examines strengths, weaknesses, and clinical applications of CSP performed via these approaches. RECENT FINDINGS His bundle pacing (HBP) has been successfully utilized for standard bradyarrhythmia indications and for QRS correction among patients receiving devices for cardiac resynchronization therapy (CRT). Limitations of HBP pacing have included implant complexity and rising pacing thresholds over time. Left bundle branch area pacing (LBBAP) appears to deliver similar physiological benefits with shorter implant times and more stable thresholds. More recently, hybrid systems utilizing HBP or LBBAP in combination with left ventricular leads have been used to treat heart failure (HF) patients, and may be useful in multilevel or mixed conduction blocks. There is growing interest in CSP for bradycardia and HF indications, although high quality data with randomized controlled trials are needed to help guide future treatment paradigms.
Collapse
|
9
|
Sun Y, Yao X, Zhou X, Jiang C, Zhang J, Sheng X, Wang M, Yang Y, Pan Y, Su L, Chen X, Fu G. Preliminary experience of permanent left bundle branch area pacing using stylet-directed pacing lead without delivery sheath. Pacing Clin Electrophysiol 2022; 45:993-1003. [PMID: 35437783 DOI: 10.1111/pace.14504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 03/18/2022] [Accepted: 04/01/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Left bundle branch area pacing (LBBAP) aims to capture the cardiac conduction system in area of the left bundle branch. Currently, LBBAP is mainly performed using lumen-less pacing leads (LLLs) with pre-shaped sheath. However, the data on LBBAP with stylet-driven leads (SDLs) without sheath is limited. OBJECTIVE This study presents the feasibility, safety, and pacing characteristics of LBBAP using stylet-driven leads (SDLs) without the support of sheath. METHODS A total of 25 patients with bradycardia indications who received LBBAP implantation with an attempt of SDL (FINELINE II 4471 lead, Boston Scientific, MA, US) between August 2020 and April 2021 at Sir Run Run Shaw Hospital were included in this retrospective cohort study. Twenty of them finally were paced with SDL in priority (SDL-LBBAP group). Twenty propensity score matching patients who underwent LBBAP with LLL (Select Secure 3830 lead, Medtronic, MN, US) and 20 right ventricular septal pacing (RVSP) with regular active fixation lead respectively in the same period (the LLL-LBBAP group and RVSP group) were compared using ECG characteristics, pacing parameters and complications during 6-month follow-up. RESULTS LBBAP was successful with SDL in 23 of 25 patients (92%) and 20 of them were paced with SDL first. In the SDL-LBBAP group, the average age was 70.4 ± 8.2 years, and 55% of patients were male. Paced QRS duration and the stimulus to peak left ventricular activation time (Sti-LVAT) in SDL-LBBAP group were similar with those in LLL-LBBAP group and significantly shorter than those in RVSP group (126.1±14.1ms vs 124.8±10.9ms, P = 1.00; 77.7±11.2ms vs 73.5±9.3ms, P = 0.75; 126.1±14.1ms vs 147.7±22.5ms, P<0.001; 77.7±11.2ms vs 97.0±13.2ms, P<0.001). The pacing threshold and R-wave amplitude of SDL-LBBAP group were 0.53±0.18V and 11.53±3.63mV at baseline respectively, which were comparable with the other two groups. During the 6-month follow-up, the pacing parameters remained stable and no lead-related complication was recorded. CONCLUSION It is feasible and safe to use stylet-directed pacing lead for permanent LBBAP without a delivery sheath. Similar to LLL, LBBAP using SDL showed stable parameters and narrower paced QRS duration compared with RVSP, which could be an alternative to LLL in LBBAP. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Yaxun Sun
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Xiaofeng Yao
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Xiang Zhou
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Chenyang Jiang
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Jiefang Zhang
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Xia Sheng
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Min Wang
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Ying Yang
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Yiwen Pan
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Lan Su
- Department of Cardiology, First Affiliated Hospital of Wenzhou Medical University, Key Lab of Cardiovascular Disease of Wenzhou, Wenzhou, China
| | - Xueying Chen
- Department of Cardiology, Shanghai Institution of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Guosheng Fu
- Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
10
|
Ferrari ADL, Gazzoni GF, Domingues LML, Willes JCF, Cabral GC, Ferreira FVC, Lodi LO, Reis G. Sincronia Ventricular na Estimulação Cardíaca Parahissiana: Alternativa por Ativação Cardíaca Fisiológica (Estimulação Indireta do Feixe de His)? Arq Bras Cardiol 2021; 118:488-502. [PMID: 35262586 PMCID: PMC8856677 DOI: 10.36660/abc.20201233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 02/24/2021] [Indexed: 11/23/2022] Open
Abstract
Fundamento A estimulação cardíaca artificial (ECA) por captura direta ou indireta do feixe de His resulta em contração ventricular sincrônica (ECA fisiológica). Objetivos Comparar sincronia cardíaca, características técnicas e resultados de parâmetros eletrônicos entre duas técnicas de ECA indireta do feixe de His: a não seletiva e a parahissiana. Métodos Intervenção experimental (novembro de 2019 a abril de 2020) com implante de marca-passo definitivo (MPd) DDD em pacientes com fração de ejeção ventricular esquerda > 35%. Foram comparadas a sincronia cardíaca resultante mediante algoritmo de análise eletrocardiográfica da variância espacial do QRS e as características técnicas associadas a cada método entre ECA hissiana não seletiva (DDD-His) e parahissiana (DDD-Var). Resultados De 51 pacientes (28 homens), 34 (66,7%) foram alocados no grupo DDD-Var e 17 (33,3%), no grupo DDD-His, com idade média de 74 e 79 anos, respectivamente. No grupo DDD-Var, a análise da variância espacial do QRS (índice de sincronia ventricular) mostrou melhora após o implante de MPd (p < 0,001). Ao ECG pós-implante, 91,2% dos pacientes do grupo DDD-Var mostraram padrão fisiológico de ECA, comprovando ativação similar à do DDD-His (88,2%; p = 0,999). O eixo do QRS estimulado também foi similar (fisiológico) para ambos os grupos. A mediana do tempo de fluoroscopia do implante foi de 7 minutos no grupo DDD-Var e de 21 minutos no DDD-His (p < 0,001), favorecendo a técnica parahissiana. A duração média do QRS aumentou nos pacientes do DDD-Var (114,7 ms pré-MPd e 128,2 ms pós-implante, p = 0,044). A detecção da onda R foi de 11,2 mV no grupo DDD-Var e de 6,0 mV no DDD-His (p = 0,001). Conclusão A ECA parahissiana comprova recrutamento indireto do feixe de His, mostrando-se uma estratégia eficaz e comparável à ECA fisiológica ao resultar em contração ventricular sincrônica similar à obtida por captura hissiana não seletiva.
Collapse
|
11
|
Abstract
Right ventricular pacing for bradycardia remains the mainstay of pacing therapy. Chronic right ventricular pacing may lead to pacing-induced cardiomyopathy. We focus on the anatomy of the conduction system and the clinical feasibility of pacing the His bundle and/or left bundle conduction system. We review the hemodynamics of conduction system pacing, the techniques to capture the conduction system and the electrocardiogram and pacing definitions of conduction system capture. Clinical studies of conduction system pacing in the setting of atrioventricular block and after AV junction ablation are reviewed and the evolving role of conduction system pacing is compared with biventricular pacing.
Collapse
|
12
|
Shah RL, Kapoor R, Badhwar N. Deformation of stylet-driven leads & helix unraveling during acute explant after conduction system pacing. Indian Pacing Electrophysiol J 2021; 21:321-323. [PMID: 34118434 PMCID: PMC8414328 DOI: 10.1016/j.ipej.2021.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/27/2021] [Accepted: 06/04/2021] [Indexed: 10/25/2022] Open
Affiliation(s)
- Rajan L Shah
- Section of Cardiac Electrophysiology, Stanford University Medicine Partners, Oakland, CA, USA; Stanford Health Care, Palo Alto, CA, USA.
| | - Ridhima Kapoor
- Department of Medicine, Stanford University School of Medicine, Stanford, CA, USA.
| | - Nitish Badhwar
- Stanford Health Care, Palo Alto, CA, USA; Department of Medicine, Stanford University School of Medicine, Stanford, CA, USA.
| |
Collapse
|
13
|
Zingarini G, Notaristefano F, Spighi L, Bagliani G, Cavallini C. Permanent His bundle pacing using a new tridimensional delivery sheath and a standard active fixation pacing lead: The telescopic technique. J Cardiovasc Electrophysiol 2021; 32:449-457. [DOI: 10.1111/jce.14869] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/20/2020] [Accepted: 12/28/2020] [Indexed: 12/27/2022]
Affiliation(s)
| | | | - Lorenzo Spighi
- Department of Cardiology University Hospital of Perugia Italy
| | - Giuseppe Bagliani
- Department of Arrhythmology, IRCCS San Donato Hospital San Raffaele University Milan Italy
| | | |
Collapse
|
14
|
De Pooter J, Calle S, Timmermans F, Van Heuverswyn F. Left bundle branch area pacing using stylet‐driven pacing leads with a new delivery sheath: A comparison with lumen‐less leads. J Cardiovasc Electrophysiol 2021; 32:439-448. [DOI: 10.1111/jce.14851] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 11/26/2020] [Accepted: 12/13/2020] [Indexed: 11/30/2022]
Affiliation(s)
- Jan De Pooter
- Heart Center Ghent University Hospital Ghent Belgium
| | - Simon Calle
- Heart Center Ghent University Hospital Ghent Belgium
| | | | | |
Collapse
|
15
|
Hua W, Zhang S, Huang D. The implantation technique in His-bundle pacing: evolution and perspectives. Europace 2020; 22:ii3-ii9. [PMID: 33370796 DOI: 10.1093/europace/euaa331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Wei Hua
- The Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167, Beilishi Road, Xicheng District, Beijing 100037, China
| | - Shu Zhang
- The Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167, Beilishi Road, Xicheng District, Beijing 100037, China
| | - Dejia Huang
- Department of Cardiology, Huaxi Hospital of Sichuan University, Chengdu 610041, China
| |
Collapse
|
16
|
Arnold AD, Whinnett ZI, Vijayaraman P. His-Purkinje Conduction System Pacing: State of the Art in 2020. Arrhythm Electrophysiol Rev 2020; 9:136-145. [PMID: 33240509 PMCID: PMC7675135 DOI: 10.15420/aer.2020.14] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 06/30/2020] [Indexed: 01/02/2023] Open
Abstract
Conduction system pacing involves directly stimulating the specialised His-Purkinje cardiac conduction system with the aim of activating the ventricles physiologically, in contrast to the dyssynchronous activation produced by conventional myocardial pacing. Since the first report of permanent His bundle pacing (HBP) in 2000, the stylet-driven technique of its earliest incarnation has been superseded by a more successful stylet-less approach. Widespread uptake has led to a much greater evidence base. Single-centre observational studies have now been supported by large multicentre, international registries, mechanistic studies and the first randomised controlled trials. New evidence has elucidated mechanisms of HBP and illustrated the nature and magnitude of its potential benefits for preventing pacing-induced cardiomyopathy and correcting bundle branch block. Left bundle branch pacing (LBBP) is a newer technique in which the lead is fixed deep into the left side of the intraventricular septum to allow capture of the left bundle, distal to the His bundle. LBBP holds promise as a method for physiological pacing that overcomes some of the fixation, threshold and sensing challenges of HBP. In this state-of-the-art review of His-Purkinje conduction system pacing, the authors assess recent evidence and current practice and explore emerging and future directions in this rapidly evolving field.
Collapse
Affiliation(s)
- Ahran D Arnold
- National Heart and Lung Institute, Imperial College London, London, UK
| | | | - Pugazhendhi Vijayaraman
- Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, Pennsylvania, US
| |
Collapse
|
17
|
Carter SV, Jameria Z, Karagodin I, Tung R, Upadhyay GA. Real-world safety of magnetic resonance imaging after His bundle pacemaker implantation. HeartRhythm Case Rep 2020; 6:697-701. [PMID: 33101935 PMCID: PMC7573342 DOI: 10.1016/j.hrcr.2020.06.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
18
|
Stylet-directed His bundle lead placement: Early days of an emerging contender. Heart Rhythm 2019; 16:1832-1833. [PMID: 31476411 DOI: 10.1016/j.hrthm.2019.08.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Indexed: 11/21/2022]
|