1
|
Nakao Y, Yoshida K, Inaba S, Tanabe Y, Kurata A, Uetani T, Kido T, Inoue K, Mochizuki T, Yamaguchi O. Plaque Characterization with Computed Tomography Angiography Based on a Diluted-contrast Injection Protocol. Intern Med 2021; 60:3671-3678. [PMID: 34853256 PMCID: PMC8710393 DOI: 10.2169/internalmedicine.6683-20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Objective Coronary plaques with low attenuation on computed tomography (CT) angiography may indicate vulnerable plaques. However, plaque CT attenuation is reported to be significantly affected by intracoronary attenuation. Recently, the diluted-contrast injection protocol was established to facilitate more uniform intracoronary attenuation than can be achieved with the generally used body-weight-adjusted protocol. We validated the relationship between low-attenuation plaque on CT and lipid-rich plaque using integrated backscatter-intravascular ultrasound (IB-IVUS) as the standard reference. Methods Plaques were divided into tertiles (T1, T2, and T3) according to the plaque CT attenuation, calculated as the average of five intra-plaque regions of interest, and compared with the plaque characteristics noted on IB-IVUS. Patients Patients who underwent both CT angiography using a diluted-contrast injection protocol and IB-IVUS were retrospectively analyzed. Results Thirty-nine plaques in 32 patients were analyzed by CT angiography and IB-IVUS. The median plaque CT attenuation (Hounsfield units) of each tertile was 30 (T1), 48 (T2), and 68 (T3). Although no significant difference was noted in conventional quantitative IVUS parameters (e.g. plaque burden), the T1 with lowest plaque CT attenuation had the highest percentage lipid area by IB-IVUS [75.1% (T1), 57.8% (T2), and 50.8% (T3), respectively, p<0.01]. Furthermore, the plaque CT attenuation had a significant negative correlation with the percentage lipid area (r=-0.59, p<0.01). Conclusion CT angiography-based plaque characterization using a diluted-contrast injection protocol may aid in the quantitative detection of lipid-rich plaque.
Collapse
Affiliation(s)
- Yasuhisa Nakao
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Japan
| | - Kazuki Yoshida
- Department of Radiology, Ehime University Graduate School of Medicine, Japan
| | - Shinji Inaba
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Japan
| | - Yuki Tanabe
- Department of Radiology, Ehime University Graduate School of Medicine, Japan
| | - Akira Kurata
- Department of Radiology, Ehime University Graduate School of Medicine, Japan
| | - Teruyoshi Uetani
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Japan
| | - Katsuji Inoue
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Japan
| | - Teruhito Mochizuki
- Department of Radiology, Ehime University Graduate School of Medicine, Japan
| | - Osamu Yamaguchi
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Japan
| |
Collapse
|
2
|
Does the Tube Voltage Affect the Characterization of Coronary Plaques on 100- and 120-kVp Computed Tomography Scans. J Comput Assist Tomogr 2019; 43:416-422. [PMID: 30762654 DOI: 10.1097/rct.0000000000000845] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of this study was to compare the diagnostic performance of 100- and 120-kVp coronary computed tomography (CT) angiography (CCTA) scans for the identification of coronary plaque components. METHODS We included 116 patients with coronary plaques who underwent CCTA and integrated backscatter intravascular ultrasound studies. On 100-kVp scans, we observed 24 fibrous and 24 fatty/fibrofatty plaques; on 120-kVp scans, we noted 27 fibrous and 41 fatty/fibrofatty plaques. We compared the fibrous and the fatty/fibrofatty plaques, the CT number of the coronary lumen, and the radiation dose on scans obtained at 100 and 120 kVp. We also compared the area under the receiver operating characteristic (ROC) curve of the coronary plaques on 100- and 120-kVp scans with their ROC curves on integrated backscatter intravascular ultrasound images. RESULTS The mean CT numbers of fatty and fatty/fibrofatty plaques were 5.71 ± 36.5 and 76.6 ± 33.7 Hounsfield units (HU), respectively, on 100-kVp scans; on 120-kVp scans, they were 13.9 ± 29.4 and 54.5 ± 22.3 HU, respectively. The CT number of the coronary lumen was 323.1 ± 81.2 HU, and the radiation dose was 563.7 ± 81.2 mGy-cm on 100-kVp scans; these values were 279.3 ± 61.8 HU and 819.1 ± 115.1 mGy-cm on 120-kVp scans. The results of ROC curve analysis identified 30.5 HU as the optimal diagnostic cutoff value for 100-kVp scans (area under the curve = 0.93, 95% confidence interval = 0.87-0.99, sensitivity = 95.8%, specificity = 78.9%); for 120-kVp plaque images, the optimal cutoff was 37.4 HU (area under the curve = 0.87, 95% confidence interval = 0.79-0.96, sensitivity = 82.1%, specificity = 85.7%). CONCLUSIONS For the discrimination of coronary plaque components, the diagnostic performance of 100- and 120-kVp CCTA scans is comparable.
Collapse
|
3
|
Jin CD, Kim MH, Kang EJ, Cho YR, Park TH, Lee KN, Serebruany V. Assessing Vessel Tone during Coronary Artery Spasm by Dual-Acquisition Multidetector Computed Tomography Angiography. Cardiology 2017; 139:25-32. [PMID: 29166637 DOI: 10.1159/000478926] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Accepted: 06/21/2017] [Indexed: 12/29/2022]
Abstract
BACKGROUND Diminished vascular tone is an established biomarker of heart damage. Little is known about the extent of coronary vessel tone (CVT) with spasm as assessed by dual-acquisition multidetector computed tomography angiography (MCTA) in patients with vasospastic angina (VSA). OBJECTIVE We evaluated the CVT modulated by intravenous nitrate injection (INI) using MCTA imaging in VSA patients. METHODS Twenty-one VSA patients (60 ± 9 years; 76% males) who underwent initial MCTA (without morning vasodilation), followed by an intracoronary ergonovine provocation test were included. Within 3 days after the initial MCTA patients received INI followed by 28-vessel segment spasm analyzed by MCTA 3D software, applying the following formula as the definition of CVT index (CVTI): (CSAIV nitrate - CSAinitial/CSAIV nitrate) ×100 %, where CSA is the cross-sectional area. RESULTS Compared to the initial MCTA measures, the INI provocation resulted in the significant increase of average diameter and CSA at the spasm site (2.60 mm [2.11-3.16] vs. 1.42 mm [1.13-2.13]; 5.37 mm2 [3.67-7.54] vs. 1.62 mm2 [1.02-3.02]; p < 0.001). The CVTI at the spastic segments was higher than at the proximal reference segments (41.0% [21.8-52.3] vs. 18.8% [5.9-26.6] for CVTI diameter; 65.1% [38.6-77.0] vs. 33.9% [5.2-48.1] for CVTI CSA, respectively). To predict VSA, the cut-off value for CVTI diameter was 38.6% (AUC 0.777; 95% CI 0.653-0.901) and 62.5% (AUC 0.779; 95% CI 0.657-0.902) for CVTI CSA in a receiver-operating characteristic curve analysis, with 57.1% sensitivity and 92.9% specificity. CONCLUSIONS This novel imaging technique for assessing CVT by dual-acquisition MCTA after applying INI provocation is suitable for the detection of coronary artery spasm in patients with VSA.
Collapse
Affiliation(s)
- Cai De Jin
- Department of Cardiology, Nanjing Medical University Affiliated Wuxi Second Hospital, Wuxi, PR China
| | | | | | | | | | | | | |
Collapse
|
4
|
Iterative Image Reconstruction Improves the Accuracy of Automated Plaque Burden Assessment in Coronary CT Angiography: A Comparison With Intravascular Ultrasound. AJR Am J Roentgenol 2017; 208:777-784. [PMID: 28177655 DOI: 10.2214/ajr.16.17187] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE The purpose of this study was to determine whether use of iterative image reconstruction algorithms improves the accuracy of coronary CT angiography (CCTA) compared with intravascular ultrasound (IVUS) in semiautomated plaque burden assessment. MATERIALS AND METHODS CCTA and IVUS images of seven coronary arteries were acquired ex vivo. CT images were reconstructed with filtered back projection (FBP) and adaptive statistical (ASIR) and model-based (MBIR) iterative reconstruction algorithms. Cross-sectional images of the arteries were coregistered between CCTA and IVUS in 1-mm increments. In CCTA, fully automated (without manual corrections) and semiautomated (allowing manual corrections of vessel wall boundaries) plaque burden assessments were performed for each of the reconstruction algorithms with commercially available software. In IVUS, plaque burden was measured manually. Agreement between CCTA and IVUS was determined with Pearson correlation. RESULTS A total of 173 corresponding cross sections were included. The mean plaque burden measured with IVUS was 63.39% ± 10.63%. With CCTA and the fully automated technique, it was 54.90% ± 11.70% with FBP, 53.34% ± 13.11% with ASIR, and 55.35% ± 12.22% with MBIR. With CCTA and the semiautomated technique mean plaque burden was 54.90% ± 11.76%, 53.40% ± 12.85%, 57.09% ± 11.05%. Manual correction of the semiautomated assessments was performed in 39% of all cross sections and improved plaque burden correlation with the IVUS assessment independently of reconstruction algorithm (p < 0.0001). Furthermore, MBIR was superior to FBP and ASIR independently of assessment method (semiautomated, r = 0.59 for FBP, r = 0.52 for ASIR, r = 0.78 for MBIR, all p < 0.001; fully automated, r = 0.40 for FBP, r = 0.37 for ASIR, r = 0.53 for MBIR, all p < 0.001). CONCLUSION For the quantification of plaque burden with CCTA, MBIR led to better correlation with IVUS than did traditional reconstruction algorithms such as FBP, independently of the use of a fully automated or semiautomated assessment approach. The highest accuracy for quantifying plaque burden with CCTA can be achieved by using MBIR data with semiautomated assessment.
Collapse
|
5
|
Sandfort V, Lima JAC, Bluemke DA. Noninvasive Imaging of Atherosclerotic Plaque Progression: Status of Coronary Computed Tomography Angiography. Circ Cardiovasc Imaging 2015; 8:e003316. [PMID: 26156016 DOI: 10.1161/circimaging.115.003316] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The process of coronary artery disease progression is infrequently visualized. Intravascular ultrasound has been used to gain important insights but is invasive and therefore limited to high-risk patients. For low-to-moderate risk patients, noninvasive methods may be useful to quantitatively monitor plaque progression or regression and to understand and personalize atherosclerosis therapy. This review discusses the potential for coronary computed tomography angiography to evaluate the extent and subtypes of coronary plaque. Computed tomographic technology is evolving and image quality of the method approaches the level required for plaque progression monitoring. Methods to quantify plaque on computed tomography angiography are reviewed as well as a discussion of their use in clinical trials. Limitations of coronary computed tomography angiography compared with competing modalities include limited evaluation of plaque subcomponents and incomplete knowledge of the value of the method especially in patients with low-to-moderate cardiovascular risk.
Collapse
Affiliation(s)
- Veit Sandfort
- From the Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD (V.S., D.A.B.); and Department of Radiology (J.A.C.L.) and Cardiology Division, Department of Medicine (J.A.C.L.), Johns Hopkins University, Baltimore, MD
| | - Joao A C Lima
- From the Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD (V.S., D.A.B.); and Department of Radiology (J.A.C.L.) and Cardiology Division, Department of Medicine (J.A.C.L.), Johns Hopkins University, Baltimore, MD
| | - David A Bluemke
- From the Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD (V.S., D.A.B.); and Department of Radiology (J.A.C.L.) and Cardiology Division, Department of Medicine (J.A.C.L.), Johns Hopkins University, Baltimore, MD.
| |
Collapse
|
6
|
Specific organized substrates of ventricular fibrillation: Comparison of 320-slice CT heart images in non-ischemic ventricular fibrillation subjects with non-ischemic sustained and non-sustained ventricular tachycardia subjects. Int J Cardiol 2013; 168:1472-8. [DOI: 10.1016/j.ijcard.2012.12.052] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2012] [Revised: 12/15/2012] [Accepted: 12/24/2012] [Indexed: 02/01/2023]
|
7
|
Effect of statin treatment on coronary plaque progression - a serial coronary CT angiography study. Atherosclerosis 2013; 231:198-204. [PMID: 24267226 DOI: 10.1016/j.atherosclerosis.2013.08.019] [Citation(s) in RCA: 122] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Revised: 07/31/2013] [Accepted: 08/19/2013] [Indexed: 11/20/2022]
Abstract
OBJECTIVES Statins have been shown to reduce plaque progression using data on intravascular ultrasound, carotid intima-media thickness and coronary artery calcium scans. However, there is little data on effects of statins on plaque progression using Coronary CTA. The objective is to evaluate the effect of statin therapy on plaque progression using serial Coronary CTA (CCTA). METHODS The study included 100 consecutive patients who underwent serial Coronary CTA (mean follow up: 406 ± 92 days) for evaluation of CAD without known prior heart disease or revascularization. We performed volumetric assessment of low attenuation plaque (LAP < 30 Hounsfield units), non-calcified (NCP) and calcified plaque volumes at baseline and follow up scans for vessels >2 mm in diameter. Patients who received statins were compared to those that did not. RESULTS Total plaque progression was significantly reduced among statin user compared to non-statin users (-33.3 mm(3) ± 90.5 vs. 31.0 mm(3) ± 84.5, p = 0.0006). Statin users had significantly reduced progression of NCP volume (-47.7 mm(3) ± 71.9 vs. 13.8 mm(3) ± 76.6, p < 0.001) and significantly reduced progression of LAP volume (-12.2 mm(3) ± 19.2 vs. 5.9 mm(3) ± 23.1, p < 0.0001). When we compared for remodeling index, no statistical difference was found between the two groups (p = 0.25) and a non-significant trend toward calcium progression (29.3 mm(3) ± 67.9 vs. 10.0 mm(3) ± 53.2, p = 0.133). After adjustment for cardiovascular risk factors, mean plaque volume difference between statin and non-statin users was statistically significant for both LAP and NCP volumes (-18.1, 95% CI: -26.4, -9.8 for LAP; -101.7, 95% CI: -162.1, -41.4 for NCP; p < 0.001) respectively. CONCLUSION Statin therapy resulted in significantly lower progression of LAP and NCP plaques compared to non-statin users.
Collapse
|
8
|
Kozuki A, Shinke T, Otake H, Shite J, Matsumoto D, Kawamori H, Nakagawa M, Nagoshi R, Hariki H, Inoue T, Nishio R, Hirata KI. Feasibility of a novel radiofrequency signal analysis for in-vivo plaque characterization in humans: Comparison of plaque components between patients with and without acute coronary syndrome. Int J Cardiol 2013; 167:1591-6. [DOI: 10.1016/j.ijcard.2012.04.102] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2011] [Revised: 04/09/2012] [Accepted: 04/15/2012] [Indexed: 12/01/2022]
|
9
|
Fischer C, Hulten E, Belur P, Smith R, Voros S, Villines TC. Coronary CT angiography versus intravascular ultrasound for estimation of coronary stenosis and atherosclerotic plaque burden: A meta-analysis. J Cardiovasc Comput Tomogr 2013; 7:256-66. [DOI: 10.1016/j.jcct.2013.08.006] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Revised: 05/23/2013] [Accepted: 08/16/2013] [Indexed: 10/26/2022]
|
10
|
Evaluation of coronary artery stent patency by using 64-slice multi-detector computed tomography and conventional coronary angiography: A comparison with intravascular ultrasonography. Int J Cardiol 2013; 166:90-5. [DOI: 10.1016/j.ijcard.2011.10.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2011] [Revised: 09/19/2011] [Accepted: 10/09/2011] [Indexed: 11/21/2022]
|
11
|
Tsujita K, Sakamoto K, Kojima S, Kojima S, Takaoka N, Nagayoshi Y, Sakamoto T, Tayama S, Kaikita K, Hokimoto S, Sumida H, Sugiyama S, Nakamura S, Ogawa H. Coronary plaque component in patients with vasospastic angina: a virtual histology intravascular ultrasound study. Int J Cardiol 2013; 168:2411-5. [PMID: 23453453 DOI: 10.1016/j.ijcard.2013.02.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2012] [Revised: 11/01/2012] [Accepted: 02/05/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Coronary spasm plays an important role in the pathogenesis of ischemic heart disease. However, tissue components of coronary plaque in patients with vasospastic angina (VSA) have been unknown. This study used virtual histology (VH)-intravascular ultrasound (IVUS) to elucidate the tissue component of spastic coronary arteries and its gender differences in patients with VSA. METHODS According to acetylcholine provocation tests, the study subjects (42 patients [19 men, 23 women, 61 ± 13 years]) were divided into 2 groups: the VSA group of 26 patients and the non-VSA group of 16 patients. After nitrate injection, IVUS volumetric analysis was done, and the parameters were compared between the groups. RESULTS Although clinical demographics were almost identical between the groups, VSA group had lower plasma adiponectin level (5.9 ± 3.3 μg/ml vs. 11.2 ± 7.6 μg/ml, p=0.007) and tended to have higher high-sensitivity C-reactive protein (0.15 ± 0.24 mg/dl vs. 0.06 ± 0.04 mg/dl, p=0.1) than non-VSA group. VSA group had diffusely thickened intima (% plaque volume, 34 ± 11% vs. 27 ± 7%, p=0.01) compared with non-VSA group. However, plaque components of patients with VSA were similar with that of non-VSA patients (dense calcium, 4 ± 6% vs. 3 ± 4%; necrotic core, 10 ± 9% vs. 8 ± 6%; fibrofatty, 19 ± 16% vs. 22 ± 11%; and fibrous, 67 ± 16% vs. 67 ± 9%). Although male patients with VSA had atherogenic lipid and metabolic profiles than female VSA patients, there were no significant gender differences in the volumetric IVUS parameters and plaque components. CONCLUSIONS Compared with non-VSA patients, VSA patients had diffusely thickened fibrous-dominant coronary plaque without gender difference, and that might suggest the role of vasospasm in the development of atherosclerosis.
Collapse
Affiliation(s)
- Kenichi Tsujita
- Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Association of inflammatory markers with the morphology and extent of coronary plaque as evaluated by 64-slice multidetector computed tomography in patients with stable coronary artery disease. Int J Cardiovasc Imaging 2013; 29:1149-58. [PMID: 23358918 DOI: 10.1007/s10554-013-0181-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Accepted: 01/04/2013] [Indexed: 01/06/2023]
Abstract
We evaluated the association between inflammatory markers and coronary artery plaque assessed by 64-slice multidetector computed tomography. Coronary computed tomography angiography was performed in patients with chest discomfort suggestive of coronary artery disease (CAD). Individuals with an acute coronary syndrome were excluded from the study. Coronary plaque morphology, the number of artery segments exhibiting plaque, and the number of vessels with >50% stenosis were evaluated. Plasma levels of high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), plasminogen activator inhibitor-1, and vascular endothelial growth factor were measured. Among the 178 patients studied (age 65 ± 10 years; 70% men), 125 were diagnosed with CAD. Hs-CRP and IL-6 concentrations were significantly higher in patients with CAD than in patients without (2.73 ± 4.7 vs. 1.32 ± 2.6 mg/L, P = 0.018, and 3.06 ± 3.3 vs. 2.19 ± 2.4 pg/mL, P = 0.036). The IL-6 level was high in patients with predominantly calcified plaque, and was significantly higher in patients with 4-9 plaque segments than in those with no or 1-3 plaque segments (4.07 ± 5.3 vs. 2.19 ± 2.4 pg/mL and 2.43 ± 2.0 pg/mL, respectively, P = 0.025). The number of stenotic vessels was not significantly related to inflammatory markers. Multivariate logistic analysis revealed that plasma levels of hs-CRP but not IL-6 were associated with the presence of coronary plaque with calcification (OR 3.37, P = 0.026). This study supports the usefulness of inflammatory markers for the evaluation of coronary plaque in patients with stable CAD.
Collapse
|
13
|
Cheng L, Ma L, Schoenhagen P, Ye H, Lou X, Gao Y, Zhao X, Wang X, Dong W. Comparison of three-dimensional volume-targeted thin-slab FIESTA magnetic resonance angiography and 64-multidetector computed tomographic angiography for the identification of proximal coronary stenosis. Int J Cardiol 2012; 167:2969-76. [PMID: 22999342 DOI: 10.1016/j.ijcard.2012.08.058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2012] [Revised: 08/17/2012] [Accepted: 08/31/2012] [Indexed: 10/27/2022]
Abstract
BACKGROUND Based on recent clinical data, an imaging strategy of identifying proximal coronary disease allows further management decisions in patients with stable angina pectoris. We aimed to compare diagnostic accuracy of non-contrast fast steady-state (FIESTA) magnetic resonance angiography (MRA) with 64-multidetector computed tomographic angiography (CTA), using conventional coronary angiography (CA) as the reference standard. METHODS Thirty patients with suspected coronary artery disease consented to participate in an institutional review board-approved protocol. Coronary MRA was performed at 1.5 T using a respiratory navigator and electrocardiogram-gated three-dimensional FIESTA pulse sequence. CTA images were acquired using a 64-multidetector computed tomographic scanner, using beta blockade to reduce the heart rate to less than 70 bpm. Coronary luminal stenosis >50% was identified. Plaques were classified as non-calcified, mixed, or calcified on CTA, and as high-, intermediate-, or low-signal on FIESTA MRA. RESULTS Compared to CA, the sensitivity, specificity, and overall accuracy for detection of >50% proximal coronary stenoses were 83.0%, 86.9%, and 86.1% for MRA and 85.1%, 87.2%, and 86.8% for CTA, respectively. For the 24 calcified stenoses, MRA corrected 16 segments that overestimated on CTA and MRA had an accuracy of 75% in evaluating calcified plaques. CONCLUSIONS High-resolution three-dimensional FIESTA MRA and CTA have a similar accuracy in detecting proximal coronary stenosis. The clinical impact of identification of proximal disease in patients with stable CAD needs to be examined in future studies.
Collapse
Affiliation(s)
- Liuquan Cheng
- Department of Radiology, Chinese PLA General Hospital, Beijing, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Papaioannou TG, Schizas D, Vavuranakis M, Katsarou O, Soulis D, Stefanadis C. Quantification of new structural features of coronary plaques by computational post-hoc analysis of virtual histology-intravascular ultrasound images. Comput Methods Biomech Biomed Engin 2012; 17:643-51. [DOI: 10.1080/10255842.2012.713940] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
15
|
Sun ZH, Liu YP, Zhou DJ, Qi Y. Use of coronary CT angiography in the diagnosis of patients with suspected coronary artery disease: findings and clinical indications. J Geriatr Cardiol 2012; 9:115-22. [PMID: 22916056 PMCID: PMC3418899 DOI: 10.3724/sp.j.1263.2012.01041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2012] [Revised: 02/06/2012] [Accepted: 05/03/2012] [Indexed: 01/10/2023] Open
Abstract
Objective To investigate the clinical applications of coronary CT angiography in patients with suspected coronary artery disease and identify factors that affect CT findings. Methods Medical records of patients suspected of coronary artery disease over a period of 12 months from a tertiary teaching hospital were retrospectively reviewed. Patient age, sex (male/female), duration of symptoms and abnormal rates of coronary CT angiography scans were analysed to investigate the relationship among these parameters. The patients by age were characterized into five groups: under 36 years, 36–45 years, 46–55 years, 56–65 years and more than 66 years, respectively; while the duration of symptoms was also classified into five groups: less than one week, one week to one month, one to three months, three to six months and more than six months. Results Of the 880 patient records reviewed, 800 met the above study criteria. Five hundred and forty nine patients demonstrated abnormal CT findings (68.6%). There was no significant difference in the percentage of abnormal CT findings based on patient sex and the duration of symptoms (P = 0.14). The abnormal rates of coronary CT angiography, however, increased significantly with increasing age (P < 0.001); with patients over 65 years of age 2.5 times more likely to have an abnormal CT scan relative to a patient under 45 years. A significant difference was found between abnormal coronary CT angiography and the duration of symptoms (P = 0.012). Conclusions Our results indicate coronary CT angiography findings are significantly related to the patient age group and duration of symptoms. Clinical referral for coronary CT angiography of patients with suspected coronary artery disease needs to be justified with regard to the judicious use of this imaging modality.
Collapse
Affiliation(s)
- Zhong-Hua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, GPO Box, U1987, Perth, Western Australia 6845, Australia
| | | | | | | |
Collapse
|
16
|
Yamaki T, Kawasaki M, Jang IK, Raffel OC, Ishihara Y, Okubo M, Kubota T, Hattori A, Nishigaki K, Takemura G, Fujiwara H, Minatoguchi S. Comparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques. Cardiovasc Ultrasound 2012; 10:33. [PMID: 22867277 PMCID: PMC3495226 DOI: 10.1186/1476-7120-10-33] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2012] [Accepted: 07/29/2012] [Indexed: 11/10/2022] Open
Abstract
Background The purpose of this study was to determine the cut-off values of Hounsfield units (HU) for the discrimination of plaque components and to evaluate the feasibility of measurement of the volume of plaque components using multi-detector row computed tomography (MDCT). Methods Coronary lesions (125 lesions in 125 patients) were visualized by both integrated backscatter intravascular ultrasound (IB-IVUS) and 64-slice MDCT at the same site. The IB values were used as a gold standard to determine the cut off values of HU for the discrimination of plaque components. Results Plaques were classified as lipid pool (n =50), fibrosis (n =65) or calcification (n =35) by IB-IVUS. The HU of lipid pool, fibrosis and calcification were 18 ± 18 HU (−19 to 58 HU), 95 ± 24 HU (46 to 154 HU) and 378 ± 99 HU (188 to 605 HU), respectively. Using receiver operating characteristic curve analysis, a threshold of 50 HU was the optimal cutoff values to discriminate lipid pool from fibrosis. Lipid volume measured by MDCT was correlated with that measured by IB-IVUS (r =0.66, p <0.001), whereas fibrous volume was not (r =0.21, p =0.059). Conclusion Lipid volume measured by MDCT was moderately correlated with that measured by IB-IVUS. MDCT may be useful for volumetric assessment of the lipid volume of coronary plaques, whereas the assessment of fibrosis volume was unstable.
Collapse
Affiliation(s)
- Takahiko Yamaki
- Department of Cardiology, Gifu University Graduate School of Medicine, Yanagido, Japan
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Uehara M, Takaoka H, Kobayashi Y, Funabashi N. Diagnostic accuracy of 320-slice computed-tomography for detection of significant coronary artery stenosis in patients with various heart rates and heart rhythms compared with conventional coronary-angiography. Int J Cardiol 2012; 167:809-15. [PMID: 22429616 DOI: 10.1016/j.ijcard.2012.02.017] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2011] [Revised: 01/17/2012] [Accepted: 02/17/2012] [Indexed: 12/16/2022]
Abstract
PURPOSE To evaluate the diagnostic accuracy of 320-slice CT for detection of significant coronary artery stenosis in patients with various heart rates (HR) and heart rhythms, including tachycardia and chronic atrial-fibrillation (CAF) compared with conventional-coronary-angiography (CAG). MATERIALS AND METHODS One-hundred-six consecutive patients underwent both 320-slice CT and CAG within 3 months (normal-sinus-rhythm [NSR] 91.5%, CAF 8.5%, mean HR 65 ± 15 beats/min). There were no cardiac events between the 2 procedures. Patients were divided in 2 groups: Group 1 (HR <65 with NSR at CT scan, n=62), and Group 2 (HR >64 with NSR or heart rhythm irregularities at CT scan, n=44). Patients with >50% or >75% luminal stenosis on CT were compared with those with >50% or >75% stenosis on CAG, respectively. RESULTS In a segment-by-segment analysis, in all patients, sensitivity, specificity, positive (PPV) and negative predictive value (NPV) of >50% stenosis on CT for predicting >50% stenosis on CAG were 69, 98, 78, and 97%, respectively, and those of >75% stenosis on CT for predicting >75% stenosis on CAG were 78, 98, 64, and 99%, respectively. Sensitivity, specificity, PPV, and NPV of >50% and 75% stenosis on CT for predicting >50% and >75% stenosis, respectively, on CAG were comparable. Diagnostic accuracy was essentially the same in both groups. CONCLUSION 320-slice CT had high diagnostic accuracy for the detection of significant coronary artery stenosis compared with CAG. Even though the numbers were small, patients with high HR or heart rhythm irregularities might have essentially equivalent results to those with low HR with NSR.
Collapse
Affiliation(s)
- Masae Uehara
- Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba 260-8670, Japan
| | | | | | | |
Collapse
|
18
|
Wong KK, Thavornpattanapong P, Cheung SC, Sun Z, Tu J. Effect of calcification on the mechanical stability of plaque based on a three-dimensional carotid bifurcation model. BMC Cardiovasc Disord 2012; 12:7. [PMID: 22336469 PMCID: PMC3310807 DOI: 10.1186/1471-2261-12-7] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Accepted: 02/15/2012] [Indexed: 11/28/2022] Open
Abstract
Background This study characterizes the distribution and components of plaque structure by presenting a three-dimensional blood-vessel modelling with the aim of determining mechanical properties due to the effect of lipid core and calcification within a plaque. Numerical simulation has been used to answer how cap thickness and calcium distribution in lipids influence the biomechanical stress on the plaque. Method Modelling atherosclerotic plaque based on structural analysis confirms the rationale for plaque mechanical examination and the feasibility of our simulation model. Meaningful validation of predictions from modelled atherosclerotic plaque model typically requires examination of bona fide atherosclerotic lesions. To analyze a more accurate plaque rupture, fluid-structure interaction is applied to three-dimensional blood-vessel carotid bifurcation modelling. A patient-specific pressure variation is applied onto the plaque to influence its vulnerability. Results Modelling of the human atherosclerotic artery with varying degrees of lipid core elasticity, fibrous cap thickness and calcification gap, which is defined as the distance between the fibrous cap and calcification agglomerate, form the basis of our rupture analysis. Finite element analysis shows that the calcification gap should be conservatively smaller than its threshold to maintain plaque stability. The results add new mechanistic insights and methodologically sound data to investigate plaque rupture mechanics. Conclusion Structural analysis using a three-dimensional calcified model represents a more realistic simulation of late-stage atherosclerotic plaque. We also demonstrate that increases of calcium content that is coupled with a decrease in lipid core volume can stabilize plaque structurally.
Collapse
Affiliation(s)
- Kelvin Kl Wong
- School of Aerospace, Mechanical and Manufacturing Engineering, and Health Innovations Research Institute (HIRi), RMIT University, Australia
| | | | | | | | | |
Collapse
|
19
|
Ohota M, Kawasaki M, Ismail TF, Hattori K, Serruys PW, Ozaki Y. A Histological and Clinical Comparison of New and Conventional Integrated Backscatter Intravascular Ultrasound (IB-IVUS). Circ J 2012; 76:1678-86. [DOI: 10.1253/circj.cj-11-1157] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Masaya Ohota
- Department of Cardiology, Fujita Health University Hospital
- Department of Cardiology, Fujita Health University Hospital
| | - Masanori Kawasaki
- Department of Cardiology, Graduate School of Medicine, Gifu University
- Department of Cardiology, Graduate School of Medicine, Gifu University
| | - Tevfik F. Ismail
- Royal Brompton Hospital & Imperial College
- Royal Brompton Hospital & Imperial College
| | - Kousuke Hattori
- Department of Cardiology, Fujita Health University Hospital
- Department of Cardiology, Fujita Health University Hospital
| | | | - Yukio Ozaki
- Department of Cardiology, Fujita Health University Hospital
- Department of Cardiology, Fujita Health University Hospital
| |
Collapse
|
20
|
Choi YH, Hong YJ, Park IH, Jeong MH, Ahmed K, Hwang SH, Lee MG, Park KH, Sim DS, Kim JH, Ahn Y, Cho JG, Park JC, Kang JC. Relationship between coronary artery calcium score by multidetector computed tomography and plaque components by virtual histology intravascular ultrasound. J Korean Med Sci 2011; 26:1052-60. [PMID: 21860556 PMCID: PMC3154341 DOI: 10.3346/jkms.2011.26.8.1052] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Accepted: 05/11/2011] [Indexed: 11/20/2022] Open
Abstract
The aim of this study was to evaluate the relationship between coronary artery calcium score (CACS) assessed by multidetector computed tomography (MDCT) and plaque components assessed by virtual histology-intravascular ultrasound (VH-IVUS) in 172 coronary artery disease (CAD) patients with 250 coronary lesions. CACS was assessed according to Agatston scoring method by MDCT and patients were divided into four groups: Group I (CACS = 0 [n = 52]); Group II (CACS = 1-100 [n = 99]); Group III (CACS = 101-400 [n = 84]); and Group IV (CACS > 400 [n = 15]). Total atheroma volume was greatest in Group IV (152 ± 132 µL vs 171 ± 114 µL vs 195 ± 149 µL vs 321±182 µL, P < 0.001). The absolute dense calcium (DC) and necrotic core (NC) volumes were greatest, and relative DC volume was greatest in Group IV (5.5 ± 6.6 µL vs 11.0 ± 10.3 µL vs 15.6 ± 13.6 µL vs 36.6 ± 18.2 µL, P < 0.001, and 14.8 ± 18.2 µL vs 19.5 ± 18.9 µL vs 22.5 ± 19.1 µL vs 41.7 ± 27.9 µL, P < 0.001, and 6.4 ± 5.3% vs 11.0 ± 6.2% vs 14.0 ± 6.5% vs 20.0 ± 7.8%, P < 0.001, respectively). The absolute plaque and DC and NC volumes and the relative DC volume correlated positively with calcium score. CAD patients with high calcium score have more vulnerable plaque components (greater DC and NC-containing plaques) than those with low calcium score.
Collapse
Affiliation(s)
- Yun Ha Choi
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Young Joon Hong
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - In Hyae Park
- College of Nursing, Chonnam National University, Gwangju, Korea
| | - Myung Ho Jeong
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Khurshid Ahmed
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Seung Hwan Hwang
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Min Goo Lee
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Keun-Ho Park
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Doo Sun Sim
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Ju Han Kim
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Youngkeun Ahn
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Jeong Gwan Cho
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Jong Chun Park
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| | - Jung Chaee Kang
- The Heart Center, Chonnam National University Hospital, Gwangju, Korea
| |
Collapse
|