1
|
Budoff MJ, Lee HS, Roy SK, Shekar C. Efficacy and Safety of Iodixanol in Computed Coronary Tomographic Angiography and Cardiac Catheterization. J Cardiovasc Dev Dis 2023; 10:449. [PMID: 37998507 PMCID: PMC10671983 DOI: 10.3390/jcdd10110449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/26/2023] [Accepted: 10/26/2023] [Indexed: 11/25/2023] Open
Abstract
Iodixanol is an iso-osmolar non-ionic dimeric hydrophilic contrast agent with a higher viscosity than the monomeric agents. It is the only Food and Drug Administration (FDA)-approved iso-osmolar agent in the United States, and it is the only contrast agent with an FDA-approved indication for use in cardiac computed tomographic angiography (CCTA), to assist in the diagnostic evaluation of patients with suspected coronary artery disease. In clinical studies, it has been noted to have fewer side effects and similar image quality when compared to low-osmolar contrast media. This can be attributed to the pharmacological properties of iodixanol. These contrast agents are used for coronary computed tomography angiography and cardiac catheterization. In this article, the use, tolerability, and efficacy of iodixanol are reviewed, specifically evaluating the use of CCTA and coronary angiography, including outcome studies, randomized trials, and comparisons to other contrast agents.
Collapse
Affiliation(s)
- Matthew J. Budoff
- Department of Cardiology, Lundquist Institute, Harbor-UCLA Medical Center, 1124 W Carson Street, Torrance, CA 90502, USA;
| | | | - Sion K. Roy
- Department of Cardiology, Lundquist Institute, Harbor-UCLA Medical Center, 1124 W Carson Street, Torrance, CA 90502, USA;
| | - Chandana Shekar
- Department of Cardiology, College of Medicine, Banner-University of Arizona, 1111 E McDowell Road, Phoenix, AZ 85006, USA;
| |
Collapse
|
2
|
Im DJ, Kim YH, Choo KS, Kang JW, Jung JI, Won Y, Kim HR, Chung MH, Han K, Choi BW. Comparison of Coronary Computed Tomography Angiography Image Quality With High-concentration and Low-concentration Contrast Agents: The Randomized CONCENTRATE Trial. J Thorac Imaging 2023; 38:120-127. [PMID: 36821380 DOI: 10.1097/rti.0000000000000633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To confirm that the image quality of coronary computed tomography (CT) angiography with a low tube voltage (80 to 100 kVp), iterative reconstruction, and low-concentration contrast agents (iodixanol 270 to 320 mgI/mL) was not inferior to that with conventional high tube voltage (120 kVp) and high-concentration contrast agent (iopamidol 370 mgI/mL). MATERIALS AND METHODS This prospective, multicenter, noninferiority, randomized trial enrolled a total of 318 patients from 8 clinical sites. All patients were randomly assigned 1: 1: 1 for each contrast medium of 270, 320, and 370 mgI/mL. CT scans were taken with a standard protocol in the high-concentration group (370 mgI/mL) and with 20 kVp lower protocol in the low-concentration group (270 or 320 mgI/mL). Image quality and radiation dose were compared between the groups. Image quality was evaluated with a score of 1 to 4 as subject image quality. RESULTS The mean HU, signal-to-noise ratio, and contrast-to-noise ratio of the 3 groups were significantly different (all P<0.0001). The signal-to-noise ratio and contrast-to-noise ratio of the low-concentration groups were significantly lower than those of the high-concentration group (P<0.05). However, the image quality scores were not significantly different among the 3 groups (P=0.745). The dose length product and effective dose of the high-concentration group were significantly higher than those of the low-concentration group (P<0.0001 and 0.003, respectively). CONCLUSIONS The CT protocol with iterative reconstruction and lower tube voltage for low-concentration contrast agents significantly reduced the effective radiation dose (mean: 3.7±2.7 to 4.1±3.1 mSv) while keeping the subjective image quality as good as the standard protocol (mean: 5.7±3.4 mSv).
Collapse
Affiliation(s)
- Dong Jin Im
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| | - Yun-Hyeon Kim
- Department of Radiology, Chonnam National University Hospital, Chonnam University Medical School, Gwangju
| | - Ki Seok Choo
- Department of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan
| | - Joon-Won Kang
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital
| | - Yoodong Won
- Department of Radiology, Uijeongbu St. Mary's Hospital, Catholic University of Korea, Uijeongbu
| | - Hyo Rim Kim
- Department of Radiology, Yeouido St. Mary's Hospital, Catholic University of Korea, Seoul
| | - Myung Hee Chung
- Department of Radiology, Bucheon St. Mary's Hospital, Catholic University of Korea, Bucheon, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| | - Byoung Wook Choi
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine
| |
Collapse
|
3
|
The effect of scan and patient parameters on the diagnostic performance of AI for detecting coronary stenosis on coronary CT angiography. Clin Imaging 2022; 84:149-158. [DOI: 10.1016/j.clinimag.2022.01.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 01/21/2022] [Accepted: 01/24/2022] [Indexed: 11/23/2022]
|
4
|
Pop M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation-Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. CHILDREN (BASEL, SWITZERLAND) 2021; 8:children8110949. [PMID: 34828662 PMCID: PMC8623802 DOI: 10.3390/children8110949] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 10/14/2021] [Accepted: 10/20/2021] [Indexed: 11/16/2022]
Abstract
Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compare the contrast enhancement achieved by four CAs when taking into consideration CA injection parameters and patient characteristics. Methods: We performed a retrospective assessment of forty-eight consecutive cardiothoracic CTAs performed for aortic arch evaluation on children aged 0–1 year. All examinations were performed using the same 64-slice scanner and power injector using the bolus tracking technique. Axial 0.6 mm slices were used to measure large vessel enhancement using regions of interest at the level of the main pulmonary artery, ascending and descending aorta. The recorded variables included anthropometric measurements, CA type, flow rate, volume, and the average Hounsfield unit (HU) values of the blood pool. Descriptive statistics are presented as averages and standard deviations (SD) for normal distributed data or otherwise as medians and interquartile ranges (IQRs). Results: We found no statistically significant differences between age and anthropometric parameters when looking at different CAs. The median CA volume was 7 (IQR, 7–9) mL with the average flow rate of 0.94 (SD, 0.23) mL/s. Ascending aorta average HU values were 605.9 (SD, 177.23) for Iomeprol 350, 626 (SD, 183.83) for Ioversol 350, 530.83 (SD, 175.56) for Iopromide 370 and 354.91 (SD, 115.81) for Iodixanol 320. The difference in HU value for Iodixanol 320 compared to the other CAs was statistically significant. Similar differences were found for the other vascular structures. Conclusion: In CTA of infants suspected of aortic arch hypoplasia/coarctation, Iodixanol 320 provided up to 40% less enhancement of the great vessels when compared to Iomeprol 350, Ioversol 350 and Iopromide 370.
Collapse
Affiliation(s)
- Marian Pop
- ME1 Department, “George Emil Palade” University of Medicine Pharmacy Sciences and Technology of Tirgu Mures, 540142 Tirgu Mures, Romania; ; Tel.: +40-749-260-920
- Radiology and Medical Imaging Department, Tirgu Mures Emergency Institute for Cardiovascular Diseases and Heart Transplant, 540136 Tirgu Mures, Romania
| |
Collapse
|
5
|
Garcia AM, Assunção-Jr AN, Dantas-Jr RN, Parga JR, Ganem F. Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts. Br J Radiol 2020; 93:20200078. [PMID: 32816561 DOI: 10.1259/bjr.20200078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Qualitative and quantitative image analysis between Iopamidol-370 and Ioversol-320 in stents´ evaluation by coronary computed tomography angiography (CTA). METHODS Sixty-five patients with low-risk stable angina undergoing stent follow-up with coronary CTA were assigned to Iopamidol I-370 (n = 33) or Ioversol I-320 (n = 32) in this prospective, double-blind, non-inferiority, randomized trial. Stent lumen image quality was graded by 5-point Likert Scale. Lumen mean attenuation was measured at native coronary segments: pre-stent, post-stent, distal segments and at coronary plaques. Lumen attenuation increase (LAI) ratio was calculated for all stents. Heart rate (HR) variation, premature heart beats (PHB), heat sensation (HS), blooming and beam hardening were also assessed. RESULTS Image quality was similar between groups, with no significant difference (Likert score 4.48 ± 0.75 vs 4.54 ± 0.65, p = 0.5). There were similarities in LAI ratio between I-370 and I-320 (0.39 ± 0.42 vs 0.48 ± 0.44 HU, p = 0.08). Regarding lumen mean attenuation at native coronary segments, a significant difference was observed, with I-320 presenting lower values, including contrast mean attenuation in distal segments. After statistical multivariate analysis, three variables correlated with stent image quality: 1) stent diameter, 2) HR variation and 3) stent lumen LAI ratio. CONCLUSIONS There was no significant difference between Iopamidol-370 mgI ml-1 and Ioversol-320 mgI ml-1 contrasts regarding overall stent lumen image quality, which was mainly influenced by stent diameter, HR and LAI ratio.Advances in knowledge:Coronary CTA allows adequate stents' visualization and image quality is influenced by stent diameter, HR variation and LAI ratio.Stents' image quality showed no difference between different concentration contrasts (I-370 vs. I-320); however, higher concentration contrasts may provide an improved overall visualization, especially regarding coronary distal segments.
Collapse
|
6
|
Alhelaly MM, Abdelhakim AM, Ellotf H, Khaled A, Soliman AM, Attia MM. Comparative effect of iso-osmolar versus low-osmolar contrast media on vascular attenuation, image quality, and heart rate changes in coronary CT angiography: A systematic review and meta-analysis. Clin Imaging 2020; 61:69-79. [PMID: 31982704 DOI: 10.1016/j.clinimag.2020.01.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 01/14/2020] [Accepted: 01/15/2020] [Indexed: 12/01/2022]
Abstract
OBJECTIVES Comparison of iso-osmolar contrast media (IOCM) and low-osmolar contrast media (LOCM) for vascular attenuation, image quality, heart rate changes, and common patient discomfort symptoms. METHODS We searched PubMed, Web of Science, Scopus, and Cochrane Central Register of Controlled Trials (CENTRAL). We included only randomized controlled trials. Screening, data extraction, and quality assessment were done by three independent authors. RevMan 5.3 software was used for meta-analysis. RESULTS Nine studies (n = 1831 participants) were found eligible and included in the meta-analysis. There was no difference between the both contrast media for vascular attenuation (mean difference = -21.31; 95% confidence interval -49.81 to 7.19; p = 0.14), image quality (standardized mean difference = 0.13; 95% confidence interval -0.07 to 0.33; p = 0.19), heart rate variability (standardized mean difference = -0.61; 95% confidence interval -1.30 to 0.09; p = 0.09), heat sensation (risk ratio = 0.79; 95% confidence interval 0.56 to 1.11; p = 0.17), and nausea or vomiting (risk ratio = 0.82; 95% confidence interval 0.52 to 1.28; p = 0.38). Moreover, IOCM resulted in a heart rate that was lower by 0.9 beat per minute (bpm) compared to LOCM (mean difference = -0.92; 95% confidence interval -1.81 to -0.03; p = 0.04). CONCLUSIONS Both IOCM and LOCM have similar vascular enhancement, image quality, heart rate variability, and similar risk for patient discomfort. Furthermore, IOCM resulted in a slightly lower heart rate by 0.9 bpm.
Collapse
Affiliation(s)
- Mohamed M Alhelaly
- Al-Azhar University, Damietta Faculty of Medicine, New Damietta City, Damietta, Egypt.
| | | | - Hamed Ellotf
- Al-Azhar University, Damietta Faculty of Medicine, New Damietta City, Damietta, Egypt
| | - Anas Khaled
- Al-Azhar University, Damietta Faculty of Medicine, New Damietta City, Damietta, Egypt
| | - Ahmed M Soliman
- Al-Azhar University, Damietta Faculty of Medicine, New Damietta City, Damietta, Egypt
| | - Mahmoud M Attia
- Al-Azhar University, Damietta Faculty of Medicine, New Damietta City, Damietta, Egypt
| |
Collapse
|
7
|
Yuan N, Zhang X, Cao Y, Jiang X, Zhao S, Feng Y, Fan Y, Lu Z, Gao H. Contrast-enhanced computerized tomography combined with a targeted nanoparticle contrast agent for screening for early-phase non-small cell lung cancer. Exp Ther Med 2017; 14:5063-5068. [PMID: 29201215 DOI: 10.3892/etm.2017.5140] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Accepted: 05/11/2017] [Indexed: 12/13/2022] Open
Abstract
Non-small cell lung cancer (NSCLC) is a major cause of morbidity and mortality, and patients with NSCLC are frequently diagnosed at an advanced stage. This is primarily due to a lack of advanced and sensitive protocols for the detection of early stage NSCLC. Therefore, methods for the accurate diagnosis of early stage NSCLC are urgently required to improve survival rates. The present study investigated the use of contrast-enhanced computerized tomography (CECT) combined with a targeted nanoparticle contrast agent (TNCA) to diagnose early-stage NSCLC in a mice xenograft model. The TNCA used was lenvatinib, a multi-target tyrosine kinase inhibitor that inhibits vascular endothelial growth factor receptor 1-3, fibroblast growth factor receptor 1-4, platelet-derived growth factor receptor β, proto-oncogene tyrosine-protein kinase receptor Ret and mast/stem cell growth factor receptor Kit. Xenograft NSCLC mice were established and used to analyze the efficacy of CECT-TNCA compared with CT scanning alone. The TNCA was inhaled with the use of an atomizer. The results demonstrated that CECT-TNCA improved the sensitivity of the diagnosis of early stage NSCLC. In addition, imaging using the TNCA enabled the visualization of nodules in the lung in mice with early stage NSCLC. In addition, lung nodule signal enhancement was increased in CECT-TNCA compared with CT, suggesting a high accurate accumulation of the TNCA in tumor nodules. Mice diagnosed with early stage NSCLC exhibited a higher eradication rate of NSCLC after treatment with cisplatin compared with mice with advanced stage NSCLC. These data indicate that the sensitivity and accuracy of CT imaging for the diagnosis of early stage NSCLC was improved through combination with the liposome-encapsulated TNCA.
Collapse
Affiliation(s)
- Ninglu Yuan
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Xiaohe Zhang
- Department of Cardiothoracic Surgery, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Yonghui Cao
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Xiaojie Jiang
- Department of Computerized Tomography, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Si Zhao
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Yingying Feng
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Yimeng Fan
- Department of Computerized Tomography, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Zhitao Lu
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| | - Hongmei Gao
- Department of Radiology, The First Hospital of Shijiazhuang City, Shijiazhuang, Hebei 050011, P.R. China
| |
Collapse
|
8
|
Patient Comfort During Contrast Media Injection in Coronary Computed Tomographic Angiography Using Varying Contrast Media Concentrations and Flow Rates: Results From the EICAR Trial. Invest Radiol 2017; 51:810-815. [PMID: 27164459 DOI: 10.1097/rli.0000000000000284] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE Pain sensation and extravasation are potential drawbacks of contrast media (CM) injection during computed tomographic angiography. The purpose was to evaluate safety and patient comfort of higher flow rates in different CM protocols during coronary computed tomographic angiography. METHODS Two hundred consecutive patients of a double-blind randomized controlled trial (NCT02462044) were analyzed. Patients were randomized to receive 94 mL of prewarmed iopromide 240 mg I/mL at 8.3 mL/s (group I), 75 mL of 300 mg I/mL at 6.7 mL/s (group II), or 61 mL of 370 mg I/mL at 5.4 mL/s (group III), respectively. Iodine delivery rate (2.0 g I/s) and total iodine load (22.5 g I) were kept identical. Outcome was defined as intravascular enhancement, patient comfort during injection, and injection safety, expressed as the occurrence of extravasation. Patients completed a questionnaire for comfort, pain, and stress during CM injection. Comfort was graded using a 5-point scale, 1 representing "very bad" and 5 "very well." Pain was graded using a 10-point scale, 0 representing "no pain" and 10 "severe pain." Stress was graded using a 5-point scale, 1 representing "no stress" and 5 "unsustainable stress." RESULTS Mean enhancement levels within the coronary arteries were as follows: 437 ± 104 Hounsfield units (HU) (group I), 448 ± 111 HU (group II), and 447 ± 106 HU (group III), with P ≥ 0.18. Extravasation occurred in none of the patients. Median (interquartile range) for comfort, pain, and stress was, respectively, 4 (4-5), 0 (0-0), and 1 (1-2), with P ≥ 0.68. CONCLUSIONS High flow rates of prewarmed CM were safely injected without discomfort, pain, or stress. Therefore, the use of high flow rates should not be considered a drawback for CM administration in clinical practice.
Collapse
|
9
|
Hur J, Choi BW. Cardiac CT Imaging for Ischemic Stroke: Current and Evolving Clinical Applications. Radiology 2017; 283:14-28. [DOI: 10.1148/radiol.2016152043] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Jin Hur
- From the Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemungu, 120-752, Seoul, Republic of Korea
| | - Byoung Wook Choi
- From the Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemungu, 120-752, Seoul, Republic of Korea
| |
Collapse
|
10
|
Chian TC, Nassir NM, Ibrahim MI, Yusof AKM, Sabarudin A. Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings. Quant Imaging Med Surg 2017; 7:48-58. [PMID: 28275559 DOI: 10.21037/qims.2017.02.02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. METHODS Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. RESULTS Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. CONCLUSIONS There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.
Collapse
Affiliation(s)
- Teo Chee Chian
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Norziana Mat Nassir
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | - Mohd Izuan Ibrahim
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| | | | - Akmal Sabarudin
- Diagnostic Imaging & Radiotherapy Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 50300 Kuala Lumpur, Malaysia
| |
Collapse
|
11
|
Im DJ, Kim YH, Choo KS, Kang JW, Jung JI, Won Y, Kim HR, Chung MH, Han K, Choi BW. Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial. Trials 2016; 17:315. [PMID: 27418333 PMCID: PMC4946231 DOI: 10.1186/s13063-016-1441-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 06/13/2016] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND With the development of computed tomography (CT) technology, coronary CT angiography can be acquired with low doses of radiation and contrast agent without a loss of diagnostic performance. The primary objective of the CONCENTRATE study is to prove the noninferiority of the enhancement effect of low-concentration contrast agents compared to a high-concentration contrast agent of the coronary artery and myocardium with coronary CT angiography. METHODS/DESIGN The CONCENTRATE study is a prospective, multicenter, noninferiority, randomized trial evaluating the enhancement effect of low-concentration contrast agents (270 and 320 mg iodine/ml) compared with a high-concentration contrast agent (370 mg iodine/ml) in the coronary artery and myocardium of coronary artery CT angiography. The primary efficacy measurement is the enhancement of coronary arteries as measured in Hounsfield units. The target population comprises 318 patients with suspected coronary artery disease who have been referred for clinically indicated nonemergent coronary CT angiography. Eligible participants are randomized for three different concentrations of the contrast agent in a 1:1:1 allocation ratio to one of three arms. The CONCENTRATE trial is a double-blind study, where the subjects and the outcome assessor are blinded to the concentration of the contrast agent used for coronary the CT angiography. Eight clinical sites in Korea are participating in this trial. DISCUSSION The CONCENTRATE study will determine whether low-concentration contrast agents are able to provide diagnostic image quality in coronary CT angiography. TRIAL REGISTRATION NCT02549794 . Registered on 14 September 2015.
Collapse
Affiliation(s)
- Dong Jin Im
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Yun-Hyeon Kim
- Department of Radiology, Chonnam National University Hospital, Chonnam University Medical School, Gwangju, Republic of Korea
| | - Ki Seok Choo
- Department of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Pusan, Republic of Korea
| | - Joon-Won Kang
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Jung Im Jung
- Department of Radiology, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Yoodong Won
- Department of Radiology, Uijeongbu St. Mary's Hospital, Catholic University of Korea, Uijeongbu, Republic of Korea
| | - Hyo Rim Kim
- Department of Radiology, Yeouido St. Mary's Hospital, Catholic University of Korea, Seoul, Republic of Korea
| | - Myung Hee Chung
- Department of Radiology, Bucheon St. Mary's Hospital, Catholic University of Korea, Bucheon, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Byoung Wook Choi
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea. .,Department of Radiology, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|