1
|
Kirshenbaum M, Ziv-Baran T, Katorza E. Amniotic fluid index measurements in the second and third trimester and correlation to fetal biometric parameters - new reference based on a big retrospective data. J Matern Fetal Neonatal Med 2021; 35:8176-8180. [PMID: 34470112 DOI: 10.1080/14767058.2021.1965981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Estimation of amniotic fluid volume (AFV) is part of routine obstetric sonography which reflects maternal-fetal circulation efficiency, fetal hemodynamic status, and a parameter for predicting adverse neonatal outcome. Fetal weight is positively correlated with AFV. Therefore, our objective is to provide a new nomogram of AFV indices and to evaluate the relation between AFV and fetal biometric parameters. MATERIALS AND METHODS Retrospective cohort study between 2011 and 2018, at a large tertiary medical center. Data were collected from medical charts of prenatal sonographic evaluation of normal pregnancies, including routine estimation of AFV by using amniotic fluid index (AFI). Generalized estimating equations model was used to study the association between AFI, gestational age and fetal biometric parameters. Centiles were calculated using the Generalized Additive Models for Location, Scale, and Shape model. Box-Cox-t distribution and smoothing splines were used. RESULTS Analysis included 28,650 pregnancies. From 25 to 41 weeks gestation, the median and fifth percentile AFI gradually decreased from 174 (IQR 157-193) to 138 mm (IQR 107-173) and from 125 to 68 mm, respectively. The change in the 95th percentile was less significant, ranging around 230 mm throughout pregnancy. Multivariate regression analysis demonstrated a significant correlation between AFI and maternal body mass index (B = -0.147; CI = -0.27 to -0.02), gestational age (B = -11.8; CI = -12.5 to -11.4), estimated fetal weight (EFW) (B = 0.05; CI = 0.049-0.053) and abdominal circumference (AC) (B = 0.94; CI = 0.95-1). There was no correlation between AFI and other fetal biometric parameters. CONCLUSIONS We suggest new AFI indices of singleton pregnancies. We found a positive correlation between AFI and EFW and AC.
Collapse
Affiliation(s)
- Michal Kirshenbaum
- Department of Obstetrics and Gynecology, Sheba Medical Center, Ramat-Gan, Israel.,Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Tomer Ziv-Baran
- Department of Epidemiology and Preventive Medicine, School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Eldad Katorza
- Department of Obstetrics and Gynecology, Sheba Medical Center, Ramat-Gan, Israel.,Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| |
Collapse
|
2
|
Weissbach T, Kassif E, Kushnir A, Shust‐Barequet S, Leibovitch L, Eliasi E, Elkan‐Miller T, Zajicek M, Yinon Y, Weisz B. Esophageal atresia in twins compared to singletons: In utero manifestation and characteristics. Prenat Diagn 2020; 40:1418-1425. [DOI: 10.1002/pd.5785] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/29/2020] [Accepted: 07/07/2020] [Indexed: 12/17/2022]
Affiliation(s)
- Tal Weissbach
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Eran Kassif
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Anya Kushnir
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Shir Shust‐Barequet
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Leah Leibovitch
- Department of Neonatology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Elior Eliasi
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Tal Elkan‐Miller
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Michal Zajicek
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Yoav Yinon
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| | - Boaz Weisz
- Department of Obstetrics and Gynecology, Sheba Medical Center, Tel Hashomer, Sackler School of Medicine Tel Aviv University Tel Aviv Israel
| |
Collapse
|
3
|
Seaman RD, Cassady CI, Yepez Donado MC, Espinoza J, Shamshirsaz AA, Nassr AA, Whitehead WE, Belfort MA, Sanz Cortes M. Postoperative imaging following fetal open myelomeningocele repair: The clinical utility of magnetic resonance imaging and sonographic amniotic fluid volumes in detecting suspected hysterotomy scar dehiscence. Prenat Diagn 2019; 40:66-70. [PMID: 31600420 DOI: 10.1002/pd.5565] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 08/20/2019] [Accepted: 09/07/2019] [Indexed: 11/10/2022]
Abstract
OBJECTIVES Hysterotomy scar disruption, ranging from myometrial thinning to complete dehiscence, is a well-established complication of open-hysterotomy fetal myelomeningocele (MMC) repair. This study sought to (a) determine the feasibility of postoperative magnetic resonance imaging (MRI) in detecting signs of hysterotomy scar disruption and (b) identify the sonographic and clinical signs suggestive of subacute scar dehiscence, including decreasing amniotic fluid index (AFI) and uterine contractions, respectively. METHOS A unique index case of suspected hysterotomy dehiscence following MMC repair prompted a retrospective review of 31 total open-hysterotomy fetal MMC repairs performed at our center, including 21 cases found to have intact hysterotomy scarring and 10 cases of non intact scarring detected at subsequent cesarean delivery. In each case, routine post operative MRI, performed 6 weeks after the MMC repair, was reviewed to evaluate the thickness of the hysterotomy site. Cases were also reviewed for sonographic and clinical patterns preceding delivery, including changes in AFI and the presence or absence of uterine contractions. RESULTS Of the 31 total reviewed cases, 21 cases were found to have intact hysterotomy scar sites at the time of cesarean delivery. Among the intact cases, the net change in AFI from the time of MRI to delivery ranged from -45% to 47%, with a mean increase in fluid levels of 8% over an average of 5.6 weeks. The other 11 cases, including the index case, were found to have signs of scar disruption at delivery, including seven with thinned scar sites and four with grossly dehiscent sites. Amongst non-intact cases, AFI predominately decreased, with a net change ranging from -56% to 9% for a mean change of -24% over an average of 5.4 weeks. Regular uterine contractions close to the time of delivery occurred in 82% of the non intact cases. CONCLUSION Hysterotomy scar disruption can rarely be detected by MRI following MMC repair. Decreasing AFI and contractions may serve as early warning signs of scar dehiscence and should be taken into consideration for obstetric management.
Collapse
Affiliation(s)
- Rachel D Seaman
- Department of Obstetrics and Gynecology, Eastern Virginia Medical School, Norfolk, VA, USA.,Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - Christopher I Cassady
- Department of Pediatric Radiology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | | | - Jimmy Espinoza
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - Alireza A Shamshirsaz
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - Ahmed A Nassr
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - William E Whitehead
- Department of Pediatric Neurosurgery, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - Michael A Belfort
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| | - Magdalena Sanz Cortes
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA
| |
Collapse
|
4
|
Owen J, Albert PS, Buck Louis GM, Fuchs KM, Grobman WA, Kim S, D'Alton ME, Wapner R, Wing DA, Grantz KL. A contemporary amniotic fluid volume chart for the United States: The NICHD Fetal Growth Studies-Singletons. Am J Obstet Gynecol 2019; 221:67.e1-67.e12. [PMID: 30790566 PMCID: PMC6592729 DOI: 10.1016/j.ajog.2019.02.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 02/11/2019] [Accepted: 02/14/2019] [Indexed: 11/20/2022]
Abstract
BACKGROUND Amniotic fluid is essential to normal fetal development and is estimated clinically with ultrasound scanning to identify pregnancies that are at risk for poor perinatal outcome. OBJECTIVE Our goal was to develop a United States standard for amniotic fluid volume that is estimated by the amniotic fluid index and single deepest pocket. STUDY DESIGN We performed a planned secondary analysis of a multicenter observational study of 2334 low-risk women with normal singleton gestations from 1 of 4 self-reported racial/ethnic groups. Eligible women had confirmed first-trimester dating criteria with health status, lifestyles, and medical and obstetric histories that were associated with normal fetal growth. Consenting women underwent serial (up to 5) sonographic evaluations of amniotic fluid between 15 and 40 weeks of gestation after being assigned randomly to 1 of 4 gestational age observation schedules. Twelve United States perinatal centers participated, and all sonograms were performed by credentialed sonographers who used identical, high-resolution equipment; caregivers were unaware of results but were notified for oligohydramnios. Women (n=597) who were subsequently found to have clinically significant antepartum complications were excluded. Racial/ethnic-specific nomograms for amniotic fluid index and single deepest pocket across gestation were developed with the use of linear mixed models with cubic splines; racial/ethnic differences were evaluated both with global and between-group tests. Median, 3rd, 5th, 10th, 90th, 95th and 97th percentile values were also estimated. We further considered the possible confounding effects of selected maternal characteristics and the estimated fetal weight at each sonogram. RESULTS A total of 1719 pregnant women met inclusion criteria and had available data. These included 480 non-Hispanic white women, 418 non-Hispanic black women, 485 Hispanic women, and 336 Asian women. Both the amniotic fluid index and the single deepest pocket varied across gestation with maximal values at 26 and 33 weeks of gestation, respectively. Statistically significant differences were observed by maternal race/ethnicity. The between-group differences that were observed at 17-22 and 35-40 weeks of gestation remained statistically significant after adjustment for maternal characteristics and estimated fetal weight. These between-group racial/ethnic differences were most prominent after 35 weeks of gestation and at the extremes of dispersion (3rd and 97th percentiles). All 3rd and 97th percentile amniotic fluid index values were within the range of commonly used cutoffs to define oligohydramnios (≤5 cm) and polyhydramnios (≥25 cm). However, the 3rd percentile values ranged between 5.9 cm at 40 weeks of gestation and 10.1 cm at 25-27 weeks of gestation; the 97th percentile values ranged between 24.8 cm at 38 weeks of gestation and 15.7 cm at 15 weeks of gestation. CONCLUSION Sonographic amniotic fluid volume estimates vary by racial/ethnic group, but the absolute differences appear to be small and may not be clinically significant. Selected maternal characteristics and estimated fetal weight did not affect the racial/ethnic differences. Between-group differences are maximal after 35 weeks of gestation and at the extremes of the upper and lower dispersion estimates. Given the observed variability in extreme (3rd and 97th percentile) dispersion values over the gestation, use of single cutoffs to define out-of-range measurements may not be appropriate clinically. These data might form a contemporary United States standard for amniotic fluid estimation that uses the amniotic fluid index and the single deepest pocket.
Collapse
Affiliation(s)
- John Owen
- University of Alabama at Birmingham School of Medicine, Center for Women's Reproductive Health, Maternal Fetal Medicine Division, Department of Obstetrics and Gynecology, Birmingham, AL.
| | - Paul S Albert
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD
| | - Germaine M Buck Louis
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD
| | | | | | - Sungduk Kim
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD
| | | | | | - Deborah A Wing
- University of California, Irvine, Miller Children's Hospital/Long Beach Memorial Medical Center, Orange, CA
| | - Katherine L Grantz
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD
| |
Collapse
|
5
|
Luntsi G, Burabe FA, Ogenyi PA, Zira JD, Chigozie NI, Nkubli FB, Dauda M. Sonographic Estimation of Amniotic Fluid Volume Using the Amniotic Fluid Index and the Single Deepest Pocket in a Resource-Limited Setting. J Med Ultrasound 2018; 27:63-68. [PMID: 31316214 PMCID: PMC6607887 DOI: 10.4103/jmu.jmu_26_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 06/18/2018] [Indexed: 11/04/2022] Open
Abstract
Objective To determine the normal value of amniotic fluid (AF) volume among pregnant women in a Northern Nigerian population and to determine if there is a relationship between AF index (AFI) and single deepest pocket (SDP) with anthropometric variables. Materials and Methods A prospective cross-sectional study was conducted among singleton pregnant women at late second and third trimester attending the antenatal clinic in Abubakar Tafawa Balewa Teaching Hospital, Bauchi, from December 2016 to April 2017. The mean AFI and SDP were measured by sonography. Ethical approval was obtained from the institution and informed consent was sought for from all the participants. Descriptive statistics, i.e. mean, standard deviation, and correlation coefficient, were used for the analysis. Results A total of 206 women, aged between 18 and 40 years, with fetal gestational ages between 22 and 39 weeks were included in the study. The values for AFI in the study ranged from 12 to 28.7 cm, with a mean value of 19.84 ± 3.64 cm, and SDP ranged from 3.7 to 9.1 cm with a mean value of 6.04 ± 1.12 cm. This study found a weak relationship between the anthropometric variables and AFI and SDP and a strong relationship between AFI and SDP with a correlation coefficient of R = 0.901 and P = 0.014. Conclusion This study found the mean values for AF volume using AFI and SDP in the studied population to be 19.84 ± 3.64 cm and 6.04 ± 1.12 cm, respectively; a strong positive relationship between AFI and SDP; and a negative relationship between body mass index with AFI and SDP.
Collapse
Affiliation(s)
- Geofery Luntsi
- Department of Medical Radiography, College of Medical Sciences, University of Maiduguri, Maiduguri, Nigeria
| | - Falmata Ali Burabe
- Department of Medical Radiography, College of Medical Sciences, University of Maiduguri, Maiduguri, Nigeria
| | - Prince Ame Ogenyi
- Department of Radiology, Abubakar Tafawa Balewa University Teaching Hospital, Bauchi, Nigeria
| | - Joseph Dlama Zira
- Department of Radiology, Abubakar Tafawa Balewa University Teaching Hospital, Bauchi, Nigeria
| | - Nwobi Ivor Chigozie
- Department of Medical Radiography, College of Medical Sciences, University of Maiduguri, Maiduguri, Nigeria
| | - Flavious Bobuin Nkubli
- Department of Medical Radiography, College of Medical Sciences, University of Maiduguri, Maiduguri, Nigeria
| | - Maikudi Dauda
- Department of Medical Radiography, College of Medical Sciences, University of Maiduguri, Maiduguri, Nigeria
| |
Collapse
|
6
|
Agwu EJ, Ugwu AC, Shem SL, Abba M. Relationship of amniotic fluid index (AFI) in third trimester with fetal weight and gender in a southeast Nigerian population. Acta Radiol Open 2016; 5:2058460116652651. [PMID: 27570636 PMCID: PMC4984320 DOI: 10.1177/2058460116652651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Accepted: 05/10/2016] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Amniotic fluid (AF) is one of the major determinants of fetal biophysical profile and can predict pregnancy outcome. Abnormal value of amniotic fluid index (AFI) may indicate fetal and maternal disorders. PURPOSE To establish reference standards for AFI for this population after 28 weeks of pregnancy and evaluate the relationship between AFI, the estimated fetal weight (EFWT), and fetal gender. MATERIAL AND METHODS A prospective cross-sectional estimation of AFI and FWT was done in 385 apparently healthy pregnant women in the gestational age range of 28-42 weeks. General scanning in longitudinal, transverse, and oblique directions of the abdomen was done to assess the fetal wellbeing and determine the fetal gender for each participant. AF was measured in each of the quadrants of the abdomen. The four values of the AF were summed to get the AFI. Measurement of the head circumference, biparietal diameter, abdominal circumference, and femoral length of the fetus were obtained. The EFWT was calculated using Hadlock's formula. The data were divided into five groups: 28-30 weeks 6 days; 31-33 weeks 6 days; 34-36 weeks 6 days; 37-39 weeks 6 days; and 40-42 weeks. AFI for the different gestational age group studied and their percentiles were obtained. RESULTS AFI normogram for the local population was established. Positive and significant correlations of AF and EFWT were seen in all the gestational age groups of the women. No significant correlations between AF and EFWT was seen in male fetuses. Regression equations of EFWT and AFI were obtained for female fetuses. CONCLUSION The normal range for AFI values for the third trimester was established and could be used to evaluate AFI in the studied population. Established fetal weight should be taken into account when interpreting AFI for female fetuses but this need not be applied for male fetuses.
Collapse
Affiliation(s)
- Emeka John Agwu
- Radiology Unit, New Hope Hospital, Onitsha Anambra State, Nigeria
| | - Anthony C Ugwu
- Department of Radiography and Radiological Sciences, Faculty of Health Sciences and Technology, Nnamdi Azikiwe University Nnewi Campus, Nigeria
| | - Samuel L Shem
- Radiology Department, State Hospital, Gombe, Nigeria
| | - Muhammed Abba
- Department of Radiography and Radiological Sciences, College of Health Sciences, Bayero University, Kano, Nigeria
| |
Collapse
|
7
|
An experimental approach to a simplified model of human birth. J Biomech 2016; 49:2313-2317. [DOI: 10.1016/j.jbiomech.2015.11.046] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Accepted: 11/03/2015] [Indexed: 11/18/2022]
|
8
|
Onwuzu S, Eze C, Ugwu L, Abonyi O, Adejoh T. Ultrasound biometry of normal human amniotic fluid index in a Nigerian population. Radiography (Lond) 2016. [DOI: 10.1016/j.radi.2015.11.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Peixoto AB, Caldas TMRDC, Martins WP, Da Silva Costa F, Araujo Júnior E. Unconditional reference values for the amniotic fluid index measurement between 26w0d and 41w6d of gestation in low-risk pregnancies. J Matern Fetal Neonatal Med 2015; 29:3243-8. [PMID: 26586609 DOI: 10.3109/14767058.2015.1123246] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To establish reference values for the amniotic fluid index (AFI) measurement between 26w0d and 41w6d of gestation in a Brazilian population. METHODS We performed a cross-sectional study with 1984 low-risk singleton pregnant women between 26w0d and 41w6d of gestation. AFI was measured according to the technique proposed by Phelan et al. Maternal abdomen was divided into four quadrants using the umbilicus and linea nigra as landmarks. Single vertical pocket in each quadrant was measured and the AFI was generated by the sum of these four values without umbilical cord or fetal parts. All ultrasound exams were performed by only two experienced examiners. AFI was expressed as median, interquartile range, mean and ranges in each gestational age (GA) interval. Polynomial regressions were performed to obtain the best fit with adjustment by the determination coefficient (R(2)). RESULTS Mean of AFI ranged from 14.0 ± 4.1 cm (range, 9.7-14.0) at 26w0d to 8.3 ± 4.7 cm (range, 1.9-16.5) at 41w6d, respectively. The best polynomial regression fit curve was a first-degree: AFI = 16.29-0.125*GA (R(2) = 0.01). According the scatterplot, AFI values practically did not vary with advancing GA. CONCLUSION Reference values for the AFI measurement between 26w0d and 41w6d of gestation in a low-risk Brazilian population were established.
Collapse
Affiliation(s)
- Alberto Borges Peixoto
- a Mário Palmério University Hospital, University of Uberaba (UNIUBE) , Uberaba , MG , Brazil .,b Radiologic Clinic of Uberaba (CRU) , Uberaba , MG , Brazil
| | - Taciana Mara Rodrigues da Cunha Caldas
- a Mário Palmério University Hospital, University of Uberaba (UNIUBE) , Uberaba , MG , Brazil .,b Radiologic Clinic of Uberaba (CRU) , Uberaba , MG , Brazil
| | - Wellington P Martins
- c Department of Obstetrics and Gynecology , Ribeirão Preto Medical School, University of São Paulo (DGO-FMRP-USP) , Ribeirão Preto, SP , Brazil
| | - Fabricio Da Silva Costa
- d Department of Perinatal Medicine , Royal Women's Hospital and Department of Obstetrics and Gynaecology, University of Melbourne , Melbourne , Victoria , Australia , and
| | - Edward Araujo Júnior
- e Department of Obstetrics , Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP) , São Paulo, SP , Brazil
| |
Collapse
|
10
|
Reference ranges of amniotic fluid index in late third trimester of pregnancy: what should the optimal interval between two ultrasound examinations be? J Pregnancy 2015; 2015:319204. [PMID: 25685558 PMCID: PMC4312643 DOI: 10.1155/2015/319204] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 11/18/2014] [Accepted: 11/20/2014] [Indexed: 11/18/2022] Open
Abstract
Background. Amniotic fluid index (AFI) is one of the major and deciding components of fetal biophysical profile and by itself it can predict pregnancy outcome. Very low values are associated with intrauterine growth restriction and renal anomalies of fetus, whereas high values may indicate fetal GI anomalies, maternal diabetes mellitus, and so forth. However, before deciding the cut-off standards for abnormal values for a local population, what constitutes a normal range for specific gestational age and the ideal interval of testing should be defined. Objectives. To establish reference standards for AFI for local population after 34 weeks of pregnancy and to decide an optimal scan interval for AFI estimation in third trimester in low risk antenatal women. Materials and Methods. A prospective estimation of AFI was done in 50 healthy pregnant women from 34 to 40 weeks at weekly intervals. The trend of amniotic fluid volume was studied with advancing gestational age. Only low risk singleton pregnancies with accurately established gestational age who were available for all weekly scan from 34 to 40 weeks were included in the study. Women with gestational or overt diabetes mellitus, hypertensive disorders of the pregnancy, prelabour rupture of membranes, and congenital anomalies in the foetus and those who delivered before 40 completed weeks were excluded from the study. For the purpose of AFI measurement, the uterine cavity was arbitrarily divided into four quadrants by a vertical and horizontal line running through umbilicus. Linear array transabdominal probe was used to measure the largest vertical pocket (in cm) in perpendicular plane to the abdominal skin in each quadrant. Amniotic fluid index was obtained by adding these four measurements. Statistical analysis was done using SPSS software (Version 16, Chicago, IL). Percentile curves (5th, 50th, and 95th centiles) were constructed for comparison with other studies. Cohen's d coefficient was used to examine the magnitude of change at different time intervals. Results. Starting from 34 weeks till 40 weeks, 50 ultrasound measurements were available at each gestational age. The mean (standard deviation) of AFI values (in cms) were 34 W: 14.59 (1.79), 35 W: 14.25 (1.57), 36 W: 13.17 (1.56), 37 W: 12.48 (1.52), 38 W: 12.2 (1.7), and 39 W: 11.37 (1.71). The 5th percentile cut-off was 8.7 cm at 40 weeks. There was a gradual decline of AFI values as the gestational age approached term. Significant drop in AFI was noted at two-week intervals. AFI curve generated from the study varied significantly when compared with already published data, both from India and abroad. Conclusion. Normative range for AFI values for late third trimester was established. Appreciable changes occurred in AFI values as gestation advanced by two weeks. Hence, it is recommended to follow up low risk antenatal women every two weeks after 34 weeks of pregnancy. The percentile curves of AFI obtained from the present study may be used to detect abnormalities of amniotic fluid for our population.
Collapse
|
11
|
Zhang G, Sun Y, Yu J, Dong L, Mu N, Liu X, Liu L, Zhang Y, Wang X, Liang P. Microwave coagulation therapy and drug injection to treat splenic injury. J Surg Res 2013; 186:226-33. [PMID: 23992856 DOI: 10.1016/j.jss.2013.07.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 07/17/2013] [Accepted: 07/18/2013] [Indexed: 10/26/2022]
Abstract
BACKGROUND The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. MATERIALS AND METHODS In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, <1 mm and B, between 1 and 2 mm), hemostatic therapy was performed using 915- and 2450-MHz microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. RESULTS The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P < 0.05). Hemostatic time, bleeding index, and bleeding volume were significantly less in the 915-MHz microwave group than those in the 2450-MHz microwave and drug injection groups (P < 0.05). Obvious degeneration and necrosis of parenchyma and large intravascular thrombosis were observed in the cavity of larger vessels in the 915-MHz microwave group, but pathologic changes of light injury could be seen in the other groups. CONCLUSIONS The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves.
Collapse
Affiliation(s)
- Guoming Zhang
- Department of Cardiology, The General Hospital of Jinan Military Region, Jinan, China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Nabhan AF, Abdelmoula YA. Amniotic fluid index versus single deepest vertical pocket: a meta-analysis of randomized controlled trials. Int J Gynaecol Obstet 2008; 104:184-8. [PMID: 19046586 DOI: 10.1016/j.ijgo.2008.10.018] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2008] [Revised: 10/07/2008] [Accepted: 10/21/2008] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To compare the use of the amniotic fluid index with the single deepest vertical pocket measurement, during antepartum fetal surveillance, in preventing adverse pregnancy outcome. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (January 2008), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2008, Issue 2), MEDLINE (1966 to May 2008), and the metaRegister of Controlled Trials (May 2008). We handsearched the citation lists of relevant publications, review articles, and included studies. SELECTION CRITERIA Randomized controlled trials involving women with a singleton pregnancy, whether at low or high risk, undergoing ultrasound measurement of amniotic fluid volume as part of antepartum assessment of fetal well-being that compared the amniotic fluid index and the single deepest vertical pocket measurement. DATA COLLECTION AND ANALYSIS Both authors independently assessed eligibility and quality, and extracted the data. RESULTS Four trials (3125 women) met the inclusion criteria. When the amniotic fluid index was used, significantly more cases of oligohydramnios were diagnosed (risk ratio (RR) 2.33, 95% CI 1.67-3.24), and more women had inductions of labor (RR 2.10, 95% CI 1.60-2.76) and cesarean delivery for fetal distress (RR 1.45, 95% CI 1.07-1.97). There is no evidence that one method is superior to the other in the prevention of poor peripartum outcomes, including: admission to a neonatal intensive care unit; an umbilical artery pH of less than 7.1; the presence of meconium; an Apgar score of less than 7 at 5 minutes; or cesarean delivery. CONCLUSION Single deepest vertical pocket measurement is the method of choice for the assessment of amniotic fluid volume.
Collapse
|
13
|
Nabhan AF, Abdelmoula YA. Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database Syst Rev 2008; 2008:CD006593. [PMID: 18646160 PMCID: PMC6464731 DOI: 10.1002/14651858.cd006593.pub2] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Amniotic fluid volume is an important parameter in the assessment of fetal well-being. Oligohydramnios occurs in many high-risk conditions and is associated with poor perinatal outcomes. Many caregivers practice planned delivery by induction of labor or caesarean section after diagnosis of decreased amniotic fluid volume at term. There is no clear consensus on the best method to assess amniotic fluid adequacy. OBJECTIVES To compare the use of the amniotic fluid index with the single deepest vertical pocket measurement as a screening tool for decreased amniotic fluid volume in preventing adverse pregnancy outcome. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (January 2008), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 2), MEDLINE (1966 to May 2007) and the metaRegister of Controlled Trials (May 2007). We handsearched the citation lists of relevant publications, review articles, and included studies. SELECTION CRITERIA Randomised controlled trials involving women with a singleton pregnancy, whether at low or high risk, undergoing ultrasound measurement of amniotic fluid volume as part of antepartum assessment of fetal well-being that compared the amniotic fluid index and the single deepest vertical pocket measurement. DATA COLLECTION AND ANALYSIS Both authors independently assessed eligibility and quality, and extracted the data. MAIN RESULTS Four trials (3125 women) met the inclusion criteria. There is no evidence that one method is superior to the other in the prevention of poor peripartum outcomes, including: admission to a neonatal intensive care unit; an umbilical artery pH of less than 7.1; the presence of meconium; an Apgar score of less than 7 at five minutes; or caesarean delivery. When the amniotic fluid index was used, significantly more cases of oligohydramnios were diagnosed (risk ratio (RR, random) 2.33, 95% CI 1.67 to 3.24), and more women had inductions of labor (RR (fixed) 2.10, 95% CI 1.60 to 2.76) and caesarean delivery for fetal distress (RR (fixed) 1.45, 95% CI 1.07 to 1.97). AUTHORS' CONCLUSIONS The single deepest vertical pocket measurement in the assessment of amniotic fluid volume during fetal surveillance seems a better choice since the use of the amniotic fluid index increases the rate of diagnosis of oligohydramnios and the rate of induction of labor without improvement in peripartum outcomes. A systematic review of the diagnostic accuracy of both methods in detecting decreased amniotic fluid volume is required.
Collapse
Affiliation(s)
- Ashraf F Nabhan
- Department of Obstetrics and Gynecology, Ain Shams University, 16 Ali Fahmi Kamel Street, Heliopolis, Cairo, Egypt, 11351.
| | | |
Collapse
|