1
|
Meijer HJA, Stellingsma K, Vissink A, Raghoebar GM. Two adjacent implant-supported restorations in the aesthetic region: A 10-year prospective case series. Clin Implant Dent Relat Res 2023; 25:1216-1224. [PMID: 37670074 DOI: 10.1111/cid.13274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 07/01/2023] [Accepted: 08/21/2023] [Indexed: 09/07/2023]
Abstract
INTRODUCTION The treatment outcome of two adjacent implant-supported restorations in the maxillary aesthetic region was assessed regarding peri-implant soft and hard tissues, and satisfaction during a 10-year follow-up period. METHODS Twenty patients missing two adjacent teeth in the maxillary aesthetic region and treated with two implant-supported restorations were followed prospectively. The patients' clinical and radiographic parameters, as well as their satisfaction, were scored for a 10-year follow-up period. RESULTS Seventeen patients' data were available for the 10-year follow-up. The survival rate of the implants and restorations was 100%. The 10-year mean peri-implant bone change at the side facing the adjacent tooth was +0.11 ± 0.57 mm and at the side facing the adjacent implant was -0.08 ± 0.50 mm. The peri-implant soft tissues were healthy and the patients' satisfaction was high, but the papilla-index showed compromised inter-implant papillae and low Pink Esthetic Scores. These figures were of the same magnitude at all time points. CONCLUSION While it is difficult to obtain sufficient inter-implant papillae and satisfactory Pink Esthetic Scores, the initial treatment results remained stable and the patients were satisfied with the final result throughout the 10-year follow-up period.
Collapse
Affiliation(s)
- Henny J A Meijer
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Department of Restorative Dentistry, Dental School, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Kees Stellingsma
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Arjan Vissink
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Gerry M Raghoebar
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
2
|
Wu H, Chen X, Kong L, Liu P. Mechanical and Biological Properties of Titanium and Its Alloys for Oral Implant with Preparation Techniques: A Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6860. [PMID: 37959457 PMCID: PMC10649385 DOI: 10.3390/ma16216860] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/23/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023]
Abstract
Dental implants have revolutionised restorative dentistry, offering patients a natural-looking and durable solution to replace missing or severely damaged teeth. Titanium and its alloys have emerged as the gold standard among the various materials available due to their exceptional properties. One of the critical advantages of titanium and its alloys is their remarkable biocompatibility which ensures minimal adverse reactions within the human body. Furthermore, they exhibit outstanding corrosion resistance ensuring the longevity of the implant. Their mechanical properties, including hardness, tensile strength, yield strength, and fatigue strength, align perfectly with the demanding requirements of dental implants, guaranteeing the restoration's functionality and durability. This narrative review aims to provide a comprehensive understanding of the manufacturing techniques employed for titanium and its alloy dental implants while shedding light on their intrinsic properties. It also presents crucial proof-of-concept examples, offering tangible evidence of these materials' effectiveness in clinical applications. However, despite their numerous advantages, certain limitations still exist necessitating ongoing research and development efforts. This review will briefly touch upon these restrictions and explore the evolving trends likely to shape the future of titanium and its alloy dental implants.
Collapse
Affiliation(s)
| | | | | | - Ping Liu
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China; (H.W.); (X.C.); (L.K.)
| |
Collapse
|
3
|
Kiechle S, Liebermann A, Mast G, Heitzer M, Möhlhenrich SC, Hölzle F, Kniha H, Kniha K. Evaluation of one-piece zirconia dental implants: An 8-year follow-up study. Clin Oral Investig 2023:10.1007/s00784-023-04935-1. [PMID: 37277537 DOI: 10.1007/s00784-023-04935-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 02/25/2023] [Indexed: 06/07/2023]
Abstract
OBJECTIVES Long-term studies of modern zirconia implants are still insufficient. This prospective 8-year follow-up study investigated one-piece zirconia implants. MATERIALS AND METHODS Patients who had received a one-piece zirconia dental implant (PURE ceramic implant, Institut Straumann GmbH, Basel, Switzerland) were included in this study. Next to the implant survival and success rates, the radiographic and clinical implant parameters were assessed. RESULTS The overall survival rate of 67 zirconia implants in 39 patients was 100%. The overall success rate was 89.6%. Around the immediate zirconia implants, the success rate was 94.7%, and around the delayed implants, 87.5%. The immediate implants showed a significantly higher bone crest compared to the delayed implants (p = 0.0120). According to the pink esthetic score, the immediate implants revealed more favorable esthetic results compared to the delayed implants after an 8-year follow-up (p = 0.0002). CONCLUSIONS After 8 years, the one-piece zirconia implants presented an 89.6% success rate. Regarding the timing of implantation, in individual cases, immediate implantation can have slight advantages over delayed implantation. CLINICAL RELEVANCE Immediate implants can also be considered for zirconia implants and should not be excluded on principle.
Collapse
Affiliation(s)
- Stella Kiechle
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital, Ludwig Maximilian University of Munich, Munich, Germany
| | - Anja Liebermann
- Department of Prosthetic Dentistry, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Strasse 32, 50931, Cologne, Germany
| | - Gerson Mast
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital, Ludwig Maximilian University of Munich, Munich, Germany
| | - Marius Heitzer
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, Aachen, Germany
| | | | - Frank Hölzle
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, Aachen, Germany
| | - Heinz Kniha
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital, Ludwig Maximilian University of Munich, Munich, Germany
- Private Clinic for Oral Surgery, Dres. Kniha, Rosental 6, Munich, Germany
| | - Kristian Kniha
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, Aachen, Germany.
- Private Clinic for Oral Surgery, Dres. Kniha, Rosental 6, Munich, Germany.
| |
Collapse
|
4
|
Wang D, Dong W. Application Effect of New Material after Surface Modification of Zirconia Ceramics and Analysis of Patient Evaluation. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:1589209. [PMID: 35837209 PMCID: PMC9276471 DOI: 10.1155/2022/1589209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/10/2022] [Accepted: 06/15/2022] [Indexed: 01/10/2023]
Abstract
Objective To explore the application effect of new material after surface modification of zirconia ceramics and patient evaluation. Methods A total of 60 patients with tooth defect treated in our hospital from April 2020 to April 2021 were selected as the study subjects and randomly divided into the control group and experimental group, with 30 cases each. The patients in the control group were treated with glass-ceramics, and those in the experimental group received LiSi surface treatment, so as to compare the application effect and patients' evaluation between the two groups. Results Between the two groups, no obvious differences in surface loss, adhesive strength, and transmittance at 3 months, 6 months, and 1 year were not observed (P > 0.05); and after intervention, the score on dental aesthetics, hardness value, and occlusal force were obviously higher in the experimental group than in the control group (P < 0.001). Conclusion The new material enables forming an acid etchable coating on the zirconia surface, increases the adhesive strength, and achieves an aesthetic degree that is welcomed by the patients; meanwhile, after grinding, the edge is defect free and the tightness is higher. Further research will help to establish a better solution for patients.
Collapse
Affiliation(s)
- Dongjiang Wang
- Department of Stomatology, Tianjin Second Hospital, Tianjin 300010, China
| | - Wenjie Dong
- Department of Stomatology, The Second Affiliated Hospital of Mudanjiang Medical College, Mudanjiang 157000, Heilongjiang, China
| |
Collapse
|
5
|
Heitzer M, Kniha K, Katz MS, Winnand P, Peters F, Möhlhenrich SC, Hölzle F, Modabber A. The primary stability of two dental implant systems in low-density bone. Int J Oral Maxillofac Surg 2022; 51:1093-1100. [PMID: 35339332 DOI: 10.1016/j.ijom.2022.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 02/18/2022] [Accepted: 02/23/2022] [Indexed: 11/19/2022]
Abstract
Primary stability in low-density bone is crucial for the long-term success of implants. Tapered implants have shown particularly favourable properties under such conditions. The aim of this study was to compare the primary stability of tapered titanium and novel cylindrical zirconia dental implant systems in low-density bone. Fifty implants (25 tapered, 25 cylindrical) were placed in the anterior maxillary bone of cadavers meeting the criteria of low-density bone. The maximum insertion (ITV) and removal (RTV) torque values were recorded, and the implant stability quotients (ISQ) determined. To establish the isolated influence of cancellous bone on primary stability, the implantation procedure was performed in standardized low-density polyurethane foam bone blocks (cancellous bone model) using the same procedure. The primary stability parameters of both implant types showed significant positive correlations with bone density (Hounsfield units) and cortical thickness. In the cadaver, the cylindrical zirconia implants showed a significantly higher mean ISQ when compared to the tapered titanium implants (50.58 vs 37.26; P < 0.001). Pearson analysis showed significant positive correlations between ITV and ISQ (P = 0.016) and between RTV and ISQ (P = 0.035) for the cylindrical zirconia implants; no such correlations were observed for the tapered titanium implants. Within the limitations of this study, the results indicate that cylindrical zirconia implants represent a comparable viable treatment option to tapered titanium implants in terms of primary implant stability in low-density human bone.
Collapse
Affiliation(s)
- M Heitzer
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany.
| | - K Kniha
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - M S Katz
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - P Winnand
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - F Peters
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - S C Möhlhenrich
- Department of Orthodontics, University of Witten/Herdecke, Witten, Germany
| | - F Hölzle
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - A Modabber
- Department of Oral and Craniomaxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
6
|
Average and Maximum Papilla Heights around Dental Implants in the Anterior Maxillary Region: A Retrospective Clinical Study. Int J Dent 2022; 2022:4235946. [PMID: 35186085 PMCID: PMC8856823 DOI: 10.1155/2022/4235946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 12/26/2021] [Accepted: 01/20/2022] [Indexed: 11/24/2022] Open
Abstract
Objective The aim of this study was to determine the average and maximum height of the papilla around maxillary anterior implants in respect of neighboring structures and location of implants. Materials and Methods 92 dental implants from 63 patients were investigated in this study. Those implants were placed in the anterior maxillary region and had been loaded for a minimum of one year. After receiving written consent, clinical data including the height of interproximal papillae adjacent to the tooth/implant/pontic were obtained through clinical observation. The independent t-test or ANOVA, the regression modeling, and generalized estimating equation (GEE) models were used for statistical analysis (p < 0.05). Results Papilla height was calculated as 2.8 mm (1–5.5 mm) for implant-tooth sites, 2.6 mm (1–4 mm) in implants beside pontics, and 2.5 mm (1–3.5 mm) for implants adjacent to implants. Despite the lack of a significant difference in the mean papilla height in the studied groups, the maximum values of papilla heights were significantly different. Conclusions In this study, no significant differences were found in papilla height mean values in relation to neighboring structures or location of implants in the anterior maxilla. However, the maximum values of papilla heights were observed around implants next to natural teeth.
Collapse
|
7
|
Kniha K, Buhl EM, Möhlhenrich SC, Bock A, Hölzle F, Hellwig E, Al-Ahmad A, Modabber A. In vivo and in vitro analysis in a rat model using zoledronate and alendronate medication: microbiological and scanning electron microscopy findings on peri-implant rat tissue. BMC Oral Health 2021; 21:672. [PMID: 34972519 PMCID: PMC8720220 DOI: 10.1186/s12903-021-02031-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 12/21/2021] [Indexed: 11/20/2022] Open
Abstract
Background The aim of the present study was to assess the development of bacterial deposits and morphological parameters around dental zirconia and titanium implants compared with natural teeth during systemic bisphosphonate medication. Materials and methods Fifty-four rats were randomly allocated into one control group and two experimental groups (drug application of zoledronic and alendronic acid), with 18 animals in each group. After 4 weeks of drug delivery, either a zirconia or a titanium implant was immediately inserted. Microbiological analysis conducted 1 week, 8 weeks, and 12 weeks after surgery included total bacterial count and composition measurements. Samples were analyzed in a scanning electron microscope (SEM) equipped with energy-dispersive X-ray spectroscopy (EDX). Bone cell morphology was analyzed by transmission electron microscopy (TEM). Results One week after surgery, titanium and zirconia implants of the alendronic acid and control group showed a significantly higher bacterial count when compared to natural teeth in rats with zoledronic acid administration (p < 0.01). Less significant differences were recorded after 3 months, at which time no inter-material differences were evaluated (p > 0.05). I
n the control group, TEM analysis showed that the osteoblasts had a strongly developed endoplasmic reticulum. In contrast, the endoplasmic reticulum of the osteoblasts in drug-treated animals was significantly less developed, indicating less activity. Conclusions Within the limits of this study, neither implant material was superior to the other at 3-month follow-up. With regard to the treatment and complications of patients with bisphosphonates, the implant material should not be an influencing factor. Bisphosphonates can be used in the rat model to reduce not only the activity of osteoclasts but also osteoblasts of the peri-implant bone.
Collapse
Affiliation(s)
- Kristian Kniha
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - Eva Miriam Buhl
- Institute of Pathology, Electron Microscopy Facility, University Hospital Aachen, Aachen, Germany
| | | | - Anna Bock
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Frank Hölzle
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Elmar Hellwig
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, Albert-Ludwigs-University, 79106, Freiburg, Germany
| | - Ali Al-Ahmad
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, Albert-Ludwigs-University, 79106, Freiburg, Germany
| | - Ali Modabber
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| |
Collapse
|
8
|
Pjetursson BE, Sailer I, Latyshev A, Rabel K, Kohal RJ, Karasan D. A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns. Clin Oral Implants Res 2021; 32 Suppl 21:254-288. [PMID: 34642991 PMCID: PMC9293296 DOI: 10.1111/clr.13863] [Citation(s) in RCA: 65] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 08/04/2021] [Indexed: 12/28/2022]
Abstract
Objective To assess the survival, failure, and complication rates of veneered and monolithic all‐ceramic implant‐supported single crowns (SCs). Methods Literature search was conducted in Medline (PubMed), Embase, and Cochrane Central Register of Controlled Trials until September 2020 for randomized, prospective, and retrospective clinical trials with follow‐up time of at least 1 year, evaluating the outcome of veneered and/or monolithic all‐ceramic SCs supported by titanium dental implants. Survival and complication rates were analyzed using robust Poisson's regression models. Results Forty‐nine RCTs and prospective studies reporting on 57 material cohorts were included. Meta‐analysis of the included studies indicated an estimated 3‐year survival rate of veneered‐reinforced glass‐ceramic implant‐supported SCs of 97.6% (95% CI: 87.0%–99.6%). The estimated 3‐year survival rates were 97.0% (95% CI: 94.0%–98.5%) for monolithic‐reinforced glass‐ceramic implant SCs, 96.9% (95% CI: 93.4%–98.6%) for veneered densely sintered alumina SCs, 96.3% (95% CI: 93.9%–97.7%) for veneered zirconia SCs, 96.1% (95% CI: 93.4%–97.8%) for monolithic zirconia SCs and only 36.3% (95% CI: 0.04%–87.7%) for resin‐matrix‐ceramic (RMC) SCs. With the exception of RMC SCs (p < 0.0001), the differences in survival rates between the materials did not reach statistical significance. Veneered SCs showed significantly (p = 0.017) higher annual ceramic chipping rates (1.65%) compared with monolithic SCs (0.39%). The location of the SCs, anterior vs. posterior, did not influence survival and chipping rates. Conclusions With the exception of RMC SCs, veneered and monolithic implant‐supported ceramic SCs showed favorable short‐term survival and complication rates. Significantly higher rates for ceramic chipping, however, were reported for veneered compared with monolithic ceramic SCs.
Collapse
Affiliation(s)
- Bjarni Elvar Pjetursson
- Department of Reconstructive Dentistry, Faculty of Odontology, University of Iceland, Reykjavik, Iceland.,Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Andrey Latyshev
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Maxillofacial, Oral and Plastic Surgery, Faculty of Dentistry, Moscow State University of Medicine and Dentistry, Moscow, Russia
| | - Kerstin Rabel
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, Freiburg, Germany
| | - Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
9
|
Ibrahim A, Heitzer M, Bock A, Peters F, Möhlhenrich SC, Hölzle F, Modabber A, Kniha K. Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E4349. [PMID: 33007841 PMCID: PMC7579538 DOI: 10.3390/ma13194349] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 09/25/2020] [Accepted: 09/27/2020] [Indexed: 12/12/2022]
Abstract
AIM This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. METHODS Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each implant was evaluated. RESULTS With an increased defect size, all implant types presented reduced implant stability values measured by the implant stability quotient (ISQ) values. Loss of stability was the most pronounced around circular defects. Zirconia and bone-level implants showed the highest ISQ values, whereas tissue level titanium implants presented the lowest stability parameters. The implant insertion without any thread cut led to a small improvement in primary implant stability in all bone densities. CONCLUSIONS Compared with implants with no peri-implant defects, the three-wall and one-wall defect usually did not provide significant loss of primary stability. A significant loss of stability should be expected when inserting implants into circular defects. Implants with a more aggressive thread distance could increase primary stability.
Collapse
Affiliation(s)
- Ahmad Ibrahim
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | - Marius Heitzer
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | - Anna Bock
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | - Florian Peters
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | | | - Frank Hölzle
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | - Ali Modabber
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| | - Kristian Kniha
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074 Aachen, Germany; (A.I.); (M.H.); (A.B.); (F.P.); (F.H.); (A.M.)
| |
Collapse
|