Cantore I. Combined Endoscopic/Microscopic Cochlear Implantation Through the Oval Window.
J Audiol Otol 2021;
26:103-107. [PMID:
34748696 PMCID:
PMC8996086 DOI:
10.7874/jao.2021.00388]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/16/2021] [Indexed: 11/29/2022] Open
Abstract
Standard round window (RW) cochlear implantation is a well-described technique. Implantation might be difficult in patients with inner and middle ear anomalies, in some cases because of not achieving adequate exposure to the RW, with a related higher risk of complications such as facial nerve injury. It is proposed a combined microscopic/endoscopic oval window approach in a 63 year old man affected by bilateral Menière disease, with bilateral severe sensorineural hearing loss, speech discrimination score for bysillabic words under 40% and a hidden RW by anomalous facial nerve course. All electrodes entered the cochlear with good freefield thresholds and auditory ability results. A partial marginalis nerve palsy occurred at the second postoperative day and completely reversed at 2 months from surgery. Endoscopicassisted oval window cochlear implantation may be a safe alternative surgical technique in cases where surgeons are not able to access RW.