1
|
Veldman-Landegent JK, van Kesteren Z, Parkes MJ, Stevens MF, van den Aardweg JG, Dieleman EM, Versteijne E, van Tienhoven G, Bel A, van Dijk IW. Noninvasive Mechanical Ventilation Is a Promising Way to Improve Lung Cancer Radiation Therapy. Adv Radiat Oncol 2025; 10:101679. [PMID: 39703719 PMCID: PMC11656083 DOI: 10.1016/j.adro.2024.101679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Accepted: 11/04/2024] [Indexed: 12/21/2024] Open
Abstract
Purpose Accurate radiation therapy (RT) for lung cancer is challenging because of the respiratory motion of the tumor and surrounding organs at risk. Recently, non-invasive mechanical ventilation (NIMV) has been investigated as a novel respiratory motion management strategy. Using NIMV, respiratory motion can be minimized, while a larger lung volume yields less overall lung dose. The purpose of this study was to determine the potential benefit of NIMV to improve lung cancer RT using magnetic resonance imaging (MRI) data of healthy volunteers. Methods and Materials Twelve healthy volunteers practiced NIMV at 60 breaths per minute (NIMV60) with added positive end-expiratory pressure (PEEP) in 2 sessions and subsequently underwent NIMV60 in 2 MRI sessions. We acquired single-slice sagittal 2-dimensional MRI images at 2.6 Hz for 6 minutes during free breathing and NIMV60. We quantified the motion of all visible cross-sections of lung arteries, as a surrogate for lung tumors, in cranio-caudal and anterior-posterior directions using deformable image registration, distinguishing between 4 quadrants in the lungs (posterior-cranial, posterior-caudal, anterior-caudal, and anterior-cranial). Also, we analyzed average lung area, as a surrogate for lung volume, on the sagittal images using automatic segmentation. Results All volunteers were successfully trained to be ventilated with NIMV60, and completed all sessions. The reduction of the median lung artery motion in each of the quadrants varied from 61% to 67% (from 10.7-29.9 to 3.8-11.7 mm) in cranio-caudal direction and from 51% to 68% (from 8.0-13.7 to 3.0-5.1 mm) in anterior-posterior direction using NIMV60. NIMV60 increased the sagittal lung area by 35% compared with free breathing. Conclusions NIMV60 with added PEEP is a promising way to improve lung cancer RT because of reduced respiratory motion and increased lung area compared with free breathing.
Collapse
Affiliation(s)
- Johannes K. Veldman-Landegent
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Zdenko van Kesteren
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Mike J. Parkes
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Markus F. Stevens
- Department of Anesthesiology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | - Joost G. van den Aardweg
- Department of Pulmonology, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | - Edith M.T. Dieleman
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Eva Versteijne
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
| | - Geertjan van Tienhoven
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Arjan Bel
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Irma W.E.M. van Dijk
- Department of Radiation Oncology, Amsterdam UMC location Free University, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| |
Collapse
|
2
|
Mitsuhashi N, Tominaga D, Ikeda H, Shiina F, Fukaya K, Nemoto Y. Effect of patient and tumor characteristics on respiratory motion in early-stage peripheral lung cancer (Tis ~ T2bN0M0) treated with stereotactic body radiation therapy (SBRT). Rep Pract Oncol Radiother 2024; 29:468-477. [PMID: 39895962 PMCID: PMC11785381 DOI: 10.5603/rpor.101531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 07/11/2024] [Indexed: 02/04/2025] Open
Abstract
Background Recent advances in stereotactic body radiation therapy (SBRT) technology for early-stage peripheral lung cancer have been remarkable and are becoming a viable alternative to surgery. However, the most important problem in performing SBRT correctly is minimizing the respiratory motion of the tumor. Materials and methods Thirty-eight patients treated with SBRT were evaluated to clarify factors affecting respiratory motion of early-stage peripheral lung cancer in the management of restrictive breathing technique (abdominal compression) to reduce respiratory tumor motion in SBRT. We investigated age, gender, body mass index (BMI), Brinkman index (BI), forced expiratory volume in 1 second (FEV 1.0), and type of ventilatory impairment as patient factors, and T-factor, stage, tumor-bearing lung lobe, and tumor pathology as tumor factors. Respiratory motion was assessed by volume differences between clinical target volume (CTV) and internal target volume (ITV). The degree of tumor motion due to respiration was compared using the formula of (ITV-CTV)/CTV as an index. Results In the results, univariate analyses showed that only age was a significant predictor of respiratory tumor motion (p = 0.048). In multi-variate analyses, only T factor was an independent significant predictor of respiratory tumor motion (p = 0.045), while there was a significant trend for age (p = 0.061), and tumor location (p = 0.067). Conclusions In late elderly patients or T1a tumor, respiratory motion in early-stage peripheral lung cancer was significantly large. However, it is not predictable by patient and tumor characteristics. Therefore, respiratory motion of the tumor should be measured in all patients in some way.
Collapse
Affiliation(s)
- Norio Mitsuhashi
- Radiation Therapy Center, Hitachinaka General Hospital, Hitachinaka, Japan
| | - Daichi Tominaga
- Radiation Therapy Center, Hitachinaka General Hospital, Hitachinaka, Japan
| | - Hajime Ikeda
- Department of Radiotherapy, Hitachinaka General Hospital, Hitachinaka, Japan
| | - Fumiya Shiina
- Radiation Therapy Center, Hitachinaka General Hospital, Hitachinaka, Japan
| | - Keiko Fukaya
- Radiation Therapy Center, Hitachinaka General Hospital, Hitachinaka, Japan
| | - Yoshitaka Nemoto
- Radiation Therapy Center, Hitachinaka General Hospital, Hitachinaka, Japan
| |
Collapse
|
3
|
Zeng Y, Gou X, Yin P, Sui X, Chen X, Hu L. The influence of respiratory movement on preoperative CT-guided localization of lung nodules. Clin Radiol 2024; 79:e963-e970. [PMID: 38589276 DOI: 10.1016/j.crad.2024.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 01/31/2024] [Accepted: 03/17/2024] [Indexed: 04/10/2024]
Abstract
AIM To evaluate the motion amplitude of lung nodules in different locations during preoperative computed tomography (CT)-guided localization, and the influence of respiratory movement on CT-guided percutaneous lung puncture. MATERIALS AND METHODS A consecutive cohort of 398 patients (123 men and 275 women with a mean age of 53.9 ± 10.7 years) who underwent preoperative CT-guided lung nodule localization from May 2021 to Apr 2022 were included in this retrospective study. The respiratory movement-related nodule amplitude in the cranial-caudal direction during the CT scan, characteristics of patients, lesions, and procedures were statistically analyzed. Univariate and multivariate logistic regression analyses were used to evaluate the influence of these factors on CT-guided localization. RESULTS The nodule motion distribution showed a statistically significant correlation within the upper/middle (lingular) and lower lobes (p<0.001). Motion amplitude was an independent risk factor for CT scan times (p=0.011) and procedure duration (p=0.016), but not for the technical failure rates or the incidence of complications. Puncture depth was an independent risk factor for the CT scan times, procedure duration, technical failure rates, and complications (p<0.01). Female, prone, and supine (as opposed to lateral) positions were significant protective factors for pneumothorax, while the supine position was an independent risk factor for parenchymal hemorrhage (p=0.025). CONCLUSION Respiratory-induced motion amplitude of nodules was greater in the lower lobes, resulting in more CT scan times/radiation dose and longer localization duration, but showed no statistically significant influence on the technical success rates or the incidence of complications during preoperative CT-guided localization.
Collapse
Affiliation(s)
- Y Zeng
- Department of Radiology, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China
| | - X Gou
- Department of Radiology, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China
| | - P Yin
- Department of Radiology, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China
| | - X Sui
- Department of Thoracic Surgery, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China
| | - X Chen
- Department of Thoracic Surgery, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China
| | - L Hu
- Department of Thoracic Surgery, Peking University People's Hospital, No.11 Xizhimen South Street, Xicheng District, Beijing, PR China.
| |
Collapse
|
4
|
Ali AM, Greenwood JB, Walls GM, Belshaw L, Agnew CE, McAleese J, Whitten G, Irvine DM, Hounsell AR, McGarry CK. Evaluation of tumour motion and internal/external correlation in lung SABR. Br J Radiol 2023; 96:20220461. [PMID: 37393541 PMCID: PMC10461274 DOI: 10.1259/bjr.20220461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 01/05/2023] [Accepted: 05/30/2023] [Indexed: 07/03/2023] Open
Abstract
OBJECTIVE This study aims to analyse lung tumour motion and to investigate the correlation between the internal tumour motion acquired from four-dimensional computed tomography (4DCT) and the motion of an external surrogate. METHODS A data set of 363 4DCT images was analysed. Tumours were classified based on their anatomical lobes. The recorded gross tumour volume (GTV) information included the centroid GTV motion in the superior-inferior, anteroposterior and left-right directions, and in three-dimensions (3D). For the internal/external correlation, the RPM surrogate breathing signals of 260 patients were analysed via an in-house script. The external motion was correlated with the 3D centroid motion, and the maximum tumour motion via Spearman's correlation. The effect of tumour volume on the amount of motion was evaluated. RESULTS The greatest 3D tumour amplitude was found for tumours located in the lower part of the lung, with a maximum of 26.7 mm. The Spearman's correlation of the internal 3D motion was weak in the upper (r = 0.21) and moderate in the middle (r = 0.51) and the lower (r = 0.52) lobes. There was no obvious difference in the correlation coefficients between the maximum tumour displacement and the centroid motion. No correlation was found between the tumour volume and the magnitude of motion. CONCLUSION Our results suggest that tumour location can be a good predictor of its motion. However, tumour size is a poor predictor of the motion. ADVANCES IN KNOWLEDGE This knowledge of the distribution of tumour motion throughout the thoracic regions will be valuable to research groups investigating the refinement of motion management strategies.
Collapse
Affiliation(s)
| | - Jason B Greenwood
- School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland
| | | | - Louise Belshaw
- Cancer Centre Belfast City Hospital, Belfast Health & Social Care Trust, Belfast, Northern Ireland
| | - Christina E Agnew
- Cancer Centre Belfast City Hospital, Belfast Health & Social Care Trust, Belfast, Northern Ireland
| | | | - Glenn Whitten
- Cancer Centre Belfast City Hospital, Belfast Health & Social Care Trust, Belfast, Northern Ireland
| | - Denise M Irvine
- Cancer Centre Belfast City Hospital, Belfast Health & Social Care Trust, Belfast, Northern Ireland
| | | | | |
Collapse
|
5
|
Jassar H, Tai A, Chen X, Keiper TD, Paulson E, Lathuilière F, Bériault S, Hébert F, Savard L, Cooper DT, Cloake S, Li XA. Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac. Med Phys 2023; 50:3103-3116. [PMID: 36893292 DOI: 10.1002/mp.16342] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/01/2023] [Accepted: 02/24/2023] [Indexed: 03/11/2023] Open
Abstract
BACKGROUND Real-time motion monitoring (RTMM) is necessary for accurate motion management of intrafraction motions during radiation therapy (RT). PURPOSE Building upon a previous study, this work develops and tests an improved RTMM technique based on real-time orthogonal cine magnetic resonance imaging (MRI) acquired during magnetic resonance-guided adaptive RT (MRgART) for abdominal tumors on MR-Linac. METHODS A motion monitoring research package (MMRP) was developed and tested for RTMM based on template rigid registration between beam-on real-time orthogonal cine MRI and pre-beam daily reference 3D-MRI (baseline). The MRI data acquired under free-breathing during the routine MRgART on a 1.5T MR-Linac for 18 patients with abdominal malignancies of 8 liver, 4 adrenal glands (renal fossa), and 6 pancreas cases were used to evaluate the MMRP package. For each patient, a 3D mid-position image derived from an in-house daily 4D-MRI was used to define a target mask or a surrogate sub-region encompassing the target. Additionally, an exploratory case reviewed for an MRI dataset of a healthy volunteer acquired under both free-breathing and deep inspiration breath-hold (DIBH) was used to test how effectively the RTMM using the MMRP can address through-plane motion (TPM). For all cases, the 2D T2/T1-weighted cine MRIs were captured with a temporal resolution of 200 ms interleaved between coronal and sagittal orientations. Manually delineated contours on the cine frames were used as the ground-truth motion. Common visible vessels and segments of target boundaries in proximity to the target were used as anatomical landmarks for reproducible delineations on both the 3D and the cine MRI images. Standard deviation of the error (SDE) between the ground-truth and the measured target motion from the MMRP package were analyzed to evaluate the RTMM accuracy. The maximum target motion (MTM) was measured on the 4D-MRI for all cases during free-breathing. RESULTS The mean (range) centroid motions for the 13 abdominal tumor cases were 7.69 (4.71-11.15), 1.73 (0.81-3.05), and 2.71 (1.45-3.93) mm with an overall accuracy of <2 mm in the superior-inferior (SI), the left-right (LR), and the anterior-posterior (AP) directions, respectively. The mean (range) of the MTM from the 4D-MRI was 7.38 (2-11) mm in the SI direction, smaller than the monitored motion of centroid, demonstrating the importance of the real-time motion capture. For the remaining patient cases, the ground-truth delineation was challenging under free-breathing due to the target deformation and the large TPM in the AP direction, the implant-induced image artifacts, and/or the suboptimal image plane selection. These cases were evaluated based on visual assessment. For the healthy volunteer, the TPM of the target was significant under free-breathing which degraded the RTMM accuracy. RTMM accuracy of <2 mm was achieved under DIBH, indicating DIBH is an effective method to address large TPM. CONCLUSIONS We have successfully developed and tested the use of a template-based registration method for an accurate RTMM of abdominal targets during MRgART on a 1.5T MR-Linac without using injected contrast agents or radio-opaque implants. DIBH may be used to effectively reduce or eliminate TPM of abdominal targets during RTMM.
Collapse
Affiliation(s)
- Hassan Jassar
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - An Tai
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Xinfeng Chen
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Timothy D Keiper
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Eric Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | | | | | | | | | | | | | - X Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| |
Collapse
|
6
|
Subashi E, Feng L, Liu Y, Robertson S, Segars P, Driehuys B, Kelsey CR, Yin FF, Otazo R, Cai J. View-sharing for 4D magnetic resonance imaging with randomized projection-encoding enables improvements of respiratory motion imaging for treatment planning in abdominothoracic radiotherapy. Phys Imaging Radiat Oncol 2023; 25:100409. [PMID: 36655213 PMCID: PMC9841273 DOI: 10.1016/j.phro.2022.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 12/24/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023] Open
Abstract
Background and Purpose The accuracy and precision of radiation therapy are dependent on the characterization of organ-at-risk and target motion. This work aims to demonstrate a 4D magnetic resonance imaging (MRI) method for improving spatial and temporal resolution in respiratory motion imaging for treatment planning in abdominothoracic radiotherapy. Materials and Methods The spatial and temporal resolution of phase-resolved respiratory imaging is improved by considering a novel sampling function based on quasi-random projection-encoding and peripheral k-space view-sharing. The respiratory signal is determined directly from k-space, obviating the need for an external surrogate marker. The average breathing curve is used to optimize spatial resolution and temporal blurring by limiting the extent of data sharing in the Fourier domain. Improvements in image quality are characterized by evaluating changes in signal-to-noise ratio (SNR), resolution, target detection, and level of artifact. The method is validated in simulations, in a dynamic phantom, and in-vivo imaging. Results Sharing of high-frequency k-space data, driven by the average breathing curve, improves spatial resolution and reduces artifacts. Although equal sharing of k-space data improves resolution and SNR in stationary features, phases with large temporal changes accumulate significant artifacts due to averaging of high frequency features. In the absence of view-sharing, no averaging and detection artifacts are observed while spatial resolution is degraded. Conclusions The use of a quasi-random sampling function, with view-sharing driven by the average breathing curve, provides a feasible method for self-navigated 4D-MRI at improved spatial resolution.
Collapse
Affiliation(s)
- Ergys Subashi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Li Feng
- Biomedical Engineering and Imaging Institute, Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Yilin Liu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Scott Robertson
- Medical Physics Graduate Program, Duke University Medical Center, Durham, NC, United States
- Department of Radiology, Duke University Medical Center, Durham, NC, United States
| | - Paul Segars
- Medical Physics Graduate Program, Duke University Medical Center, Durham, NC, United States
- Department of Radiology, Duke University Medical Center, Durham, NC, United States
| | - Bastiaan Driehuys
- Medical Physics Graduate Program, Duke University Medical Center, Durham, NC, United States
- Department of Radiology, Duke University Medical Center, Durham, NC, United States
| | - Christopher R Kelsey
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States
| | - Fang-Fang Yin
- Medical Physics Graduate Program, Duke University Medical Center, Durham, NC, United States
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| |
Collapse
|
7
|
Ohno Y, Hanamatsu S, Obama Y, Ueda T, Ikeda H, Hattori H, Murayama K, Toyama H. Overview of MRI for pulmonary functional imaging. Br J Radiol 2021; 95:20201053. [PMID: 33529053 DOI: 10.1259/bjr.20201053] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Morphological evaluation of the lung is important in the clinical evaluation of pulmonary diseases. However, the disease process, especially in its early phases, may primarily result in changes in pulmonary function without changing the pulmonary structure. In such cases, the traditional imaging approaches to pulmonary morphology may not provide sufficient insight into the underlying pathophysiology. Pulmonary imaging community has therefore tried to assess pulmonary diseases and functions utilizing not only nuclear medicine, but also CT and MR imaging with various technical approaches. In this review, we overview state-of-the art MR methods and the future direction of: (1) ventilation imaging, (2) perfusion imaging and (3) biomechanical evaluation for pulmonary functional imaging.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan.,Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Satomu Hanamatsu
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Yuki Obama
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Hirotaka Ikeda
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Hidekazu Hattori
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| | - Kazuhiro Murayama
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University, School of Medicine, Toyoake, Japan
| |
Collapse
|
8
|
Treatment planning for non-small cell lung tumours: VMAT versus 3DCRT a quantitative dosimetric study. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396919000864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurpose:The dosimetric impact of volumetric modulated arc therapy (VMAT) in lung cancer compared with 3D conformal radiotherapy (3DCRT) is well known. However, this improvement is often associated with an increase in low doses. The aim of this study is to quantify these results more accurately.Methods:For each patient treated with 3DCRT, a second VMAT treatment plan was calculated. Usual dosimetric parameters such as target coverage or dose to the organs at risk were used to achieve the comparisons.Results:For planning target volume, homogeneity and conformity indices showed superiority of VMAT (respectively 0·07 and 0·87) compared to 3DCRT (0·11 and 0·57). For spinal cord planning organ at risk volume, the median maximum dose was 45·6 Gy in 3DCRT against 19·3 Gy in VMAT. Heart volume receiving at least 35 Gy (V35) decreased from 15·64% in 3DCRT to 8·28% in VMAT. Oesophagus V50 was higher in 3DCRT (25·45%) than in VMAT (14·03%). The mean lung dose was 17·9 Gy in 3DCRT versus 15·5 Gy in VMAT. Moreover, volumes receiving 5, 10 and 15 Gy were not significantly different between the two techniques when VMAT was performed with partial arcs.Conclusion:All the dosimetric parameters were improved with VMAT compared to the 3DCRT without increasing low doses when using partial arcs.
Collapse
|
9
|
Correlating lung tumour location and motion with respiration using 4D CT scans. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396919001043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
AbstractBackground:Lung tumours, especially those in the lower lobes, can move a lot during respiration; this motion needs to be accounted for during radiotherapy. In cases where 4D CT simulation scans are not performed, the current protocol at our centre is to apply a generic (internal motion + setup) margin of 0·70 cm in the axial plane and 1·20 cm in the longitudinal plane to all lung tumours, regardless of location. We analyse the tumour motions of a cohort of our local patients and categorise them into different locations in the lung. We seek to assess the adequacy of the current margins and to derive a more accurate set of standard margins which are specific for lung tumour locations.Methods:All cases of lung tumours treated with stereotactic ablative radiotherapy between 2012 and 2016 were identified retrospectively and 4D CT scan data analysed. These tumours were grouped into the following locations: upper zone (UZ), middle zone (MZ) and lower zone (LZ). The treatment planning system was used to generate the displacements of the centre of mass of the tumours in the right–left, anterior–posterior and superior–inferior axes; these were compared with the current generic margins. Median displacements were calculated for each axis in each location. New planning target volume (PTV) margins were derived by summing the median displacement, median absolute deviation (MAD) and 0·5 cm (for setup error).Results:Sixty-three cases were eligible for analyses. Motion in the superior–inferior direction was the greatest for all tumour locations, ranging from a median of 0·17 cm (MAD 0·12 cm) in UZ to 0·77 cm (MAD 0·27 cm) in LZ. Median tumour displacements in the anterior–posterior and right–left axes were similar for all locations, <0·30 and 0·20 cm, respectively. The current generic margins were adequate for only one-third of the cases in this study. A new PTV margin of 2·10 cm in the superior–inferior axis may be required for LZ tumours, while an additional 1–2 mm should be added to the current radial margins.Conclusion:The current generic margins are inadequate for the majority of cases. Tumour motion is the greatest in LZ in the superior–inferior axis. Motion mitigation strategies are essential for large LZ tumours.
Collapse
|
10
|
Paganelli C, Portoso S, Garau N, Meschini G, Via R, Buizza G, Keall P, Riboldi M, Baroni G. Time-resolved volumetric MRI in MRI-guided radiotherapy: an in silico comparative analysis. Phys Med Biol 2019; 64:185013. [PMID: 31323645 DOI: 10.1088/1361-6560/ab33e5] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
MRI-treatment units enable 2D cine-MRI centred in the tumour for motion detection in radiotherapy, but they lack 3D information due to spatio-temporal limits. To derive time-resolved 3D information, different approaches have been proposed in the literature, but a rigorous comparison among these strategies has not yet been performed. The goal of this study is to quantitatively investigate five published strategies that derive time-resolved volumetric MRI in MRI-guided radiotherapy: Propagation, out-of-plane motion compensation, Fayad model, ROI-based model and Stemkens model. Comparisons were performed using an MRI digital phantom generated with six different patient-derived motion signals and tumour-shapes. An average 4D cycle was generated as well as 2D cine-MRI data with corresponding 3D in-room ground truth. Quantitative analysis was performed by comparing the estimated 3D volume to the ground truth available for each 2D cine-MRI sample. A grouped patient statistical analysis was performed to evaluate the performance of the selected methods, in case of tumour tracking or motion estimation of the whole anatomy. Analyses were also performed based on patient characteristics. Quantitative ranking of the investigated methods highlighted that Propagation and ROI-based model strategies achieved an overall median tumour centre of mass 3D distance from the ground truth of 1.1 mm and 1.3 mm, respectively, and a diaphragm distance below 1.6 mm. Higher errors and variabilities were instead obtained for other methods, which lack the ability to compensate for in-room variations and to account for regional changes. These results were especially evident when further analysing patient characteristics, where errors above 2 mm/5 mm in tumour/diaphragm were found for more irregular breathing patterns in case of out-of-plane motion compensation, Fayad and Stemkens models. These findings suggest the potential of the proposed in silico framework to develop and compare strategies to estimate time-resolved 3DMRI in MRI-guided radiotherapy.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Both authors contributed equally. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Knowles BR, Friedrich F, Fischer C, Paech D, Ladd ME. Beyond T2 and 3T: New MRI techniques for clinicians. Clin Transl Radiat Oncol 2019; 18:87-97. [PMID: 31341982 PMCID: PMC6630188 DOI: 10.1016/j.ctro.2019.04.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 04/11/2019] [Accepted: 04/11/2019] [Indexed: 12/12/2022] Open
Abstract
Technological advances in Magnetic Resonance Imaging (MRI) in terms of field strength and hybrid MR systems have led to improvements in tumor imaging in terms of anatomy and functionality. This review paper discusses the applications of such advances in the field of radiation oncology with regards to treatment planning, therapy guidance and monitoring tumor response and predicting outcome.
Collapse
Affiliation(s)
- Benjamin R. Knowles
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Florian Friedrich
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Carola Fischer
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Daniel Paech
- Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Mark E. Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
12
|
Chowdhury SR, Dutta J. Higher-order singular value decomposition-based lung parcellation for breathing motion management. J Med Imaging (Bellingham) 2019; 6:024004. [PMID: 31065568 DOI: 10.1117/1.jmi.6.2.024004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 04/04/2019] [Indexed: 11/14/2022] Open
Abstract
Positron emission tomography (PET) imaging of the lungs is confounded by respiratory motion-induced blurring artifacts that degrade quantitative accuracy. Gating and motion-compensated image reconstruction are frequently used to correct these motion artifacts in PET. In the absence of voxel-by-voxel deformation measures, surrogate signals from external markers are used to track internal motion and generate gated PET images. The objective of our work is to develop a group-level parcellation framework for the lungs to guide the placement of markers depending on the location of the internal target region. We present a data-driven framework based on higher-order singular value decomposition (HOSVD) of deformation tensors that enables identification of synchronous areas inside the torso and on the skin surface. Four-dimensional (4-D) magnetic resonance (MR) imaging based on a specialized radial pulse sequence with a one-dimensional slice-projection navigator was used for motion capture under free-breathing conditions. The deformation tensors were computed by nonrigidly registering the gated MR images. Group-level motion signatures obtained via HOSVD were used to cluster the voxels both inside the volume and on the surface. To characterize the parcellation result, we computed correlation measures across the different regions of interest (ROIs). To assess the robustness of the parcellation technique, leave-one-out cross-validation was performed over the subject cohort, and the dependence of the result on varying numbers of gates and singular value thresholds was examined. Overall, the parcellation results were largely consistent across these test cases with Jaccard indices reflecting high degrees of overlap. Finally, a PET simulation study was performed which showed that, depending on the location of the lesion, the selection of a synchronous ROI may lead to noticeable gains in the recovery coefficient. Accurate quantitative interpretation of PET images is important for lung cancer management. Therefore, a guided motion monitoring approach is of utmost importance in the context of pulmonary PET imaging.
Collapse
Affiliation(s)
- Samadrita Roy Chowdhury
- University of Massachusetts Lowell, Department of Electrical and Computer Engineering, Lowell, Massachusetts, United States
| | - Joyita Dutta
- University of Massachusetts Lowell, Department of Electrical and Computer Engineering, Lowell, Massachusetts, United States.,Massachusetts General Hospital and Harvard Medical School, Gordon Center for Medical Imaging, Boston, Massachusetts, United States
| |
Collapse
|
13
|
Thomas L, Schultz T, Prokic V, Guckenberger M, Tanadini-Lang S, Hohberg M, Wild M, Drzezga A, Bundschuh RA. 4D-CT-based motion correction of PET images using 3D iterative deconvolution. Oncotarget 2019; 10:2987-2995. [PMID: 31105880 PMCID: PMC6508203 DOI: 10.18632/oncotarget.26862] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 03/23/2019] [Indexed: 11/25/2022] Open
Abstract
Objectives Positron emission tomography acquisition takes several minutes representing an image averaged over multiple breathing cycles. Therefore, in areas influenced by respiratory movement, PET-positive lesions occur larger, but less intensive than they actually are, resulting in false quantitative assessment. We developed a motion-correction algorithm based on 4D-CT without the need to adapt PET-acquisition. Methods The algorithm is based on a full 3D iterative Richardson-Lucy-Deconvolution using a point-spread-function constructed using the motion information obtained from the 4D-CT. In a motion phantom study (3 different hot spheres in background activity), optimal parameters for the algorithm in terms of number of iterations and start image were estimated. Finally, the correction method was applied to 3 patient data sets. In phantom and patient data sets lesions were delineated and compared between motion corrected and uncorrected images for activity uptake and volume. Results Phantom studies showed best results for motion correction after 6 deconvolution steps or higher. In phantom studies, lesion volume improved up to 23% for the largest, 43% for the medium and 49% for the smallest sphere due to the correction algorithm. In patient data the correction resulted in a significant reduction of the tumor volume up to 33.3 % and an increase of the maximum and mean uptake of the lesion up to 62.1 and 19.8 % respectively. Conclusion In conclusion, the proposed motion correction method showed good results in phantom data and a promising reduction of detected lesion volume and a consequently increasing activity uptake in three patients with lung lesions.
Collapse
Affiliation(s)
- Lena Thomas
- Klinik und Poliklinik für Nuklearmedizin, Universitaetsklinikum Bonn, Bonn, Germany
| | - Thomas Schultz
- B-IT and Department of Computer Science, Universitaet Bonn, Bonn, Germany
| | - Vesna Prokic
- University Koblenz-Landau, Department of Physics, Koblenz, Germany.,University of Applied Sciences Koblenz, Koblenz, Germany
| | | | | | - Melanie Hohberg
- Department of Nuclear Medicine Universitaetsklinikum Köln, Cologne, Germany
| | - Markus Wild
- Department of Nuclear Medicine Universitaetsklinikum Köln, Cologne, Germany
| | - Alexander Drzezga
- Department of Nuclear Medicine Universitaetsklinikum Köln, Cologne, Germany
| | - Ralph A Bundschuh
- Klinik und Poliklinik für Nuklearmedizin, Universitaetsklinikum Bonn, Bonn, Germany
| |
Collapse
|
14
|
Sliding motion compensated low-rank plus sparse (SMC-LS) reconstruction for high spatiotemporal free-breathing liver 4D DCE-MRI. Magn Reson Imaging 2019; 58:56-66. [PMID: 30658071 DOI: 10.1016/j.mri.2019.01.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Revised: 12/06/2018] [Accepted: 01/12/2019] [Indexed: 02/03/2023]
Abstract
Liver dynamic contrast-enhanced MRI (DCE-MRI) requires high spatiotemporal resolution and large field of view to clearly visualize all relevant enhancement phases and detect early-stage liver lesions. The low-rank plus sparse (L + S) reconstruction outperforms standard sparsity-only-based reconstruction through separation of low-rank background component (L) and sparse dynamic components (S). However, the L + S decomposition is sensitive to respiratory motion so that image quality is compromised when breathing occurs during long time data acquisition. To enable high quality reconstruction for free-breathing liver 4D DCE-MRI, this paper presents a novel method called SMC-LS, which incorporates Sliding Motion Compensation into the standard L + S reconstruction. The global superior-inferior displacement of the internal abdominal organs is inferred directly from the undersampled raw data and then used to correct the breathing induced sliding motion which is the dominant component of respiratory motion. With sliding motion compensation, the reconstructed temporal frames are roughly registered before applying the standard L + S decomposition. The proposed method has been validated using free-breathing liver 4D MRI phantom data, free-breathing liver 4D DCE-MRI phantom data, and in vivo free breathing liver 4D MRI dataset. Results demonstrated that SMC-LS reconstruction can effectively reduce motion blurring artefacts and preserve both spatial structures and temporal variations at a sub-second temporal frame rate for free-breathing whole-liver 4D DCE-MRI.
Collapse
|
15
|
Paganelli C, Whelan B, Peroni M, Summers P, Fast M, van de Lindt T, McClelland J, Eiben B, Keall P, Lomax T, Riboldi M, Baroni G. MRI-guidance for motion management in external beam radiotherapy: current status and future challenges. Phys Med Biol 2018; 63:22TR03. [PMID: 30457121 DOI: 10.1088/1361-6560/aaebcf] [Citation(s) in RCA: 83] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
High precision conformal radiotherapy requires sophisticated imaging techniques to aid in target localisation for planning and treatment, particularly when organ motion due to respiration is involved. X-ray based imaging is a well-established standard for radiotherapy treatments. Over the last few years, the ability of magnetic resonance imaging (MRI) to provide radiation-free images with high-resolution and superb soft tissue contrast has highlighted the potential of this imaging modality for radiotherapy treatment planning and motion management. In addition, these advantageous properties motivated several recent developments towards combined MRI radiation therapy treatment units, enabling in-room MRI-guidance and treatment adaptation. The aim of this review is to provide an overview of the state-of-the-art in MRI-based image guidance for organ motion management in external beam radiotherapy. Methodological aspects of MRI for organ motion management are reviewed and their application in treatment planning, in-room guidance and adaptive radiotherapy described. Finally, a roadmap for an optimal use of MRI-guidance is highlighted and future challenges are discussed.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Author to whom any correspondence should be addressed. www.cartcas.polimi.it
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Li G, Sun A, Nie X, Moody J, Huang K, Zhang S, Sharma S, Deasy J. Introduction of a pseudo demons force to enhance deformation range for robust reconstruction of super-resolution time-resolved 4DMRI. Med Phys 2018; 45:5197-5207. [PMID: 30203474 DOI: 10.1002/mp.13179] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 07/30/2018] [Accepted: 08/31/2018] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The purpose of this study was to enhance the deformation range of demons-based deformable image registration (DIR) for large respiration-induced organ motion in the reconstruction of time-resolved four-dimensional magnetic resonance imaging (TR-4DMRI) for multi-breath motion simulation. METHODS A demons-based DIR algorithm was modified to enhance the deformation range for TR-4DMRI reconstruction using the super-resolution approach. A pseudo demons force was introduced to accelerate the coarse deformation in a multi-resolution (n = 3) DIR approach. The intensity gradient of a voxel was applied to its neighboring (5 × 5 × 5) voxels with a weight of Gaussian probability profile (σ = 1 voxel) to extend the demons force, especially on those voxels that have little intensity gradience but high-intensity difference. A digital 4DMRI phantom with 3-8 cm diaphragmatic motions was used for DIR comparison. Six volunteers were scanned with two high-resolution (highR: 2 × 2 × 2 mm3 ) breath-hold (BH) 3DMR images at full inhalation (BHI) and full exhalation (BHE) and low-resolution (lowR: 5 × 5 × 5 mm3 ) free-breathing (FB) 3DMR cine images (2 Hz) under an IRB-approved protocol. A cross-consistency check (CCC) (BHI→FB←BHE), with voxel intensity correlation (VIC) and inverse consistency error (ICE), was introduced for cross-verification of TR-4DMRI reconstruction. RESULTS Using the digital phantom, the maximum deformable magnitude is doubled using the modified DIR from 3 to 6 cm at the diaphragm. In six human subjects, the first 15-iteration DIR using the pseudo force deforms 200 ± 150% more than the original force, and succeeds in all 12 cases, whereas the original demons-based DIR failed in 67% of tested cases. Using the pseudo force, high VIC (>0.9) and small ICE (1.6 ± 0.6 mm) values are observed for DIR of BHI&BHE, BHI→FB, and BHE→FB. The CCC identifies four questionable cases, in which two cases need further DIR refinement, without missing true negative. CONCLUSIONS The introduction of a pseudo demons force enhances the largest deformation magnitude up to 6 cm. The cross-consistency check ensures the quality of TR-4DMRI reconstruction. Further investigation is ongoing to fully characterize TR-4DMRI for potential multi-breathing-cycle radiotherapy simulation.
Collapse
Affiliation(s)
- Guang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - August Sun
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Xingyu Nie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Jason Moody
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Kirk Huang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Shirong Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Satyam Sharma
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Joseph Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
17
|
Shahzadeh S, Gholami S, Aghamiri SMR, Mahani H, Nabavi M, Kalantari F. Evaluation of normal lung tissue complication probability in gated and conventional radiotherapy using the 4D XCAT digital phantom. Comput Biol Med 2018; 97:21-29. [PMID: 29684782 DOI: 10.1016/j.compbiomed.2018.04.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Revised: 04/10/2018] [Accepted: 04/10/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE The present study was conducted to investigate normal lung tissue complication probability in gated and conventional radiotherapy (RT) as a function of diaphragm motion, lesion size, and its location using 4D-XCAT digital phantom in a simulation study. MATERIALS AND METHODS Different time series of 3D-CT images were generated using the 4D-XCAT digital phantom. The binary data obtained from this phantom were then converted to the digital imaging and communication in medicine (DICOM) format using an in-house MATLAB-based program to be compatible with our treatment planning system (TPS). The 3D-TPS with superposition computational algorithm was used to generate conventional and gated plans. Treatment plans were generated for 36 different XCAT phantom configurations. These included four diaphragm motions of 20, 25, 30 and 35 mm, three lesion sizes of 3, 4, and 5 cm in diameter and each tumor was placed in four different lung locations (right lower lobe, right upper lobe, left lower lobe and left upper lobe). The complication of normal lung tissue was assessed in terms of mean lung dose (MLD), the lung volume receiving ≥20 Gy (V20), and normal tissue complication probability (NTCP). RESULTS The results showed that the gated RT yields superior outcomes in terms of normal tissue complication compared to the conventional RT. For all cases, the gated radiation therapy technique reduced the mean dose, V20, and NTCP of lung tissue by up to 5.53 Gy, 13.38%, and 23.89%, respectively. CONCLUSIONS The results of this study showed that the gated RT provides significant advantages in terms of the normal lung tissue complication, compared to the conventional RT, especially for the lesions near the diaphragm.
Collapse
Affiliation(s)
- Sara Shahzadeh
- Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran
| | - Somayeh Gholami
- Radiotherapy Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran.
| | | | - Hojjat Mahani
- Research Center for Molecular and Cellular Imaging, Tehran University of Medical Science, Tehran, Iran; Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
| | - Mansoure Nabavi
- Radiotherapy Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Faraz Kalantari
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
18
|
Robin P, Bourhis D, Bernard B, Abgral R, Querellou S, Le Duc-Pennec A, Le Roux PY, Salaün PY. Feasibility of Systematic Respiratory-Gated Acquisition in Unselected Patients Referred for 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography. Front Med (Lausanne) 2018. [PMID: 29516001 PMCID: PMC5826069 DOI: 10.3389/fmed.2018.00036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Objective Respiratory motion in 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) induces blurred images, leading to errors in location and quantification for lung and abdominal lesions. Various methods have been developed to correct for these artifacts, and most of current PET/CT scanners are equipped with a respiratory gating system. However, they are not routinely performed because their use is time-consuming. The aim of this study is to assess the feasibility and quantitative impact of a systematic respiratory-gated acquisition in unselected patients referred for FDG PET/CT, without increasing acquisition time. Methods Patients referred for a FDG PET/CT examination to the nuclear medicine department of Brest University Hospital were consecutively enrolled, during a 3-month period. Cases presenting lung or liver uptakes were analyzed. Two sets of images were reconstructed from data recorded during a unique acquisition with a continuous table speed of 1 mm/s of the used Biograph mCT Flow PET/CT scanner: standard free-breathing images, and respiratory-gated images. Lesion location and quantitative parameters were recorded and compared. Results From October 1 2015 to December 31 2015, 847 patients were referred for FDG PET/CT, 741 underwent a respiratory-gated acquisition. Out of them, 213 (29%) had one or more lung or liver uptake but 82 (38%) had no usable respiratory-gated signal. Accordingly, 131 (62%) patients with 183 lung or liver uptakes were analyzed. Considering the 183 lesions, 140 and 43 were located in the lungs and the liver, respectively. The median (IQR) difference between respiratory-gated images and non-gated images was 18% (4−32) for SUVmax, increasing to 30% (14−57) in lower lobes for lung lesions, and −18% (−40 to −4) for MTV (p < 0.05). Technologists’ active personal dosimetry and mean total examinations duration were not statistically different between periods with and without respiratory gating. Conclusion This study showed that a systematic respiratory-gated acquisition without increasing acquisition time is feasible in a daily routine and results in a significant impact on PET quantification. However, clinical impact on patient management remains to be determined.
Collapse
Affiliation(s)
- Philippe Robin
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - David Bourhis
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Brieuc Bernard
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Ronan Abgral
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Solène Querellou
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Alexandra Le Duc-Pennec
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Pierre-Yves Le Roux
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| | - Pierre-Yves Salaün
- Service de Médecine Nucléaire, EA 3878 (GETBO) IFR 148, Centre Hospitalier Régional et Universitaire de Brest, Université de Bretagne Occidentale, Brest, France
| |
Collapse
|
19
|
Park S, Farah R, Shea SM, Tryggestad E, Hales R, Lee J. Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning. Phys Med Biol 2018; 63:025015. [PMID: 29243669 DOI: 10.1088/1361-6560/aaa20b] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Respiration-induced tumor motion is a major obstacle for achieving high-precision radiotherapy of cancers in the thoracic and abdominal regions. Surrogate-based estimation and tracking methods are commonly used in radiotherapy, but with limited understanding of quantified correlation to tumor motion. In this study, we propose a method to simultaneously track the lung tumor and external surrogates to evaluate their spatial correlation in a quantitative way using dynamic MRI, which allows real-time acquisition without ionizing radiation exposure. To capture the lung and whole tumor, four MRI-compatible fiducials are placed on the patient's chest and upper abdomen. Two different types of acquisitions are performed in the sagittal orientation including multi-slice 2D cine MRIs to reconstruct 4D-MRI and two-slice 2D cine MRIs to simultaneously track the tumor and fiducials. A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and groupwise registration. The 4D-MRI provides 3D template volumes for different breathing phases. 3D tumor position is calculated by 3D-2D template matching in which 3D tumor templates in the 4D-MRI reconstruction and the 2D cine MRIs from the two-slice tracking dataset are registered. 3D trajectories of the external surrogates are derived via matching a 3D geometrical model of the fiducials to their segmentations on the 2D cine MRIs. We tested our method on ten lung cancer patients. Using a correlation analysis, the 3D tumor trajectory demonstrates a noticeable phase mismatch and significant cycle-to-cycle motion variation, while the external surrogate was not sensitive enough to capture such variations. Additionally, there was significant phase mismatch between surrogate signals obtained from the fiducials at different locations.
Collapse
Affiliation(s)
- Seyoun Park
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, United States of America
| | | | | | | | | | | |
Collapse
|
20
|
Blind Compressed Sensing Enables 3-Dimensional Dynamic Free Breathing Magnetic Resonance Imaging of Lung Volumes and Diaphragm Motion. Invest Radiol 2017; 51:387-99. [PMID: 26863578 DOI: 10.1097/rli.0000000000000253] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVES The objective of this study was to increase the spatial and temporal resolution of dynamic 3-dimensional (3D) magnetic resonance imaging (MRI) of lung volumes and diaphragm motion. To achieve this goal, we evaluate the utility of the proposed blind compressed sensing (BCS) algorithm to recover data from highly undersampled measurements. MATERIALS AND METHODS We evaluated the performance of the BCS scheme to recover dynamic data sets from retrospectively and prospectively undersampled measurements. We also compared its performance against that of view-sharing, the nuclear norm minimization scheme, and the l1 Fourier sparsity regularization scheme. Quantitative experiments were performed on a healthy subject using a fully sampled 2D data set with uniform radial sampling, which was retrospectively undersampled with 16 radial spokes per frame to correspond to an undersampling factor of 8. The images obtained from the 4 reconstruction schemes were compared with the fully sampled data using mean square error and normalized high-frequency error metrics. The schemes were also compared using prospective 3D data acquired on a Siemens 3 T TIM TRIO MRI scanner on 8 healthy subjects during free breathing. Two expert cardiothoracic radiologists (R1 and R2) qualitatively evaluated the reconstructed 3D data sets using a 5-point scale (0-4) on the basis of spatial resolution, temporal resolution, and presence of aliasing artifacts. RESULTS The BCS scheme gives better reconstructions (mean square error = 0.0232 and normalized high frequency = 0.133) than the other schemes in the 2D retrospective undersampling experiments, producing minimally distorted reconstructions up to an acceleration factor of 8 (16 radial spokes per frame). The prospective 3D experiments show that the BCS scheme provides visually improved reconstructions than the other schemes do. The BCS scheme provides improved qualitative scores over nuclear norm and l1 Fourier sparsity regularization schemes in the temporal blurring and spatial blurring categories. The qualitative scores for aliasing artifacts in the images reconstructed by nuclear norm scheme and BCS scheme are comparable.The comparisons of the tidal volume changes also show that the BCS scheme has less temporal blurring as compared with the nuclear norm minimization scheme and the l1 Fourier sparsity regularization scheme. The minute ventilation estimated by BCS for tidal breathing in supine position (4 L/min) and the measured supine inspiratory capacity (1.5 L) is in good correlation with the literature. The improved performance of BCS can be explained by its ability to efficiently adapt to the data, thus providing a richer representation of the signal. CONCLUSION The feasibility of the BCS scheme was demonstrated for dynamic 3D free breathing MRI of lung volumes and diaphragm motion. A temporal resolution of ∼500 milliseconds, spatial resolution of 2.7 × 2.7 × 10 mm, with whole lung coverage (16 slices) was achieved using the BCS scheme.
Collapse
|
21
|
Cho J, Cheon W, Ahn S, Jung H, Sheen H, Park HC, Han Y. Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data. JOURNAL OF RADIATION RESEARCH 2017; 58:710-719. [PMID: 28201522 PMCID: PMC5737584 DOI: 10.1093/jrr/rrw131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 06/01/2016] [Indexed: 06/06/2023]
Abstract
Target motion-induced uncertainty in particle therapy is more complicated than that in X-ray therapy, requiring more accurate motion management. Therefore, a hybrid motion-tracking system that can track internal tumor motion and as well as an external surrogate of tumor motion was developed. Recently, many correlation tests between internal and external markers in X-ray therapy have been developed; however, the accuracy of such internal/external marker tracking systems, especially in particle therapy, has not yet been sufficiently tested. In this article, the process of installing an in-house hybrid internal/external motion-tracking system is described and the accuracy level of tracking system was acquired. Our results demonstrated that the developed in-house external/internal combined tracking system has submillimeter accuracy, and can be clinically used as a particle therapy system as well as a simulation system for moving tumor treatment.
Collapse
Affiliation(s)
- Junsang Cho
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710, Korea
| | - Wonjoong Cheon
- Department of Health Sciences and Technology,
Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul 135-710, Korea
| | - Sanghee Ahn
- Department of Health Sciences and Technology,
Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul 135-710, Korea
| | - Hyunuk Jung
- Department of Health Sciences and Technology,
Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul 135-710, Korea
| | - Heesoon Sheen
- School of Medicine, Sungkyunkwan University, Seoul 135-710, Korea
- GE Healthcare Korea, Seoul, 135-100, Korea
| | - Hee Chul Park
- Department of Radiation Oncology, Samsung Medical Center, SAIHST, Sungkyunkwan University School of Medicine, Seoul 135-710, Korea
| | - Youngyih Han
- Department of Radiation Oncology, Samsung Medical Center, SAIHST, Sungkyunkwan University School of Medicine, Seoul 135-710, Korea
| |
Collapse
|
22
|
Xu Z, Yao R, Podgorsak MB, Wang IZ. Effects of collimator angle, couch angle, and starting phase on motion-tracking dynamic conformal arc therapy (4D DCAT). J Appl Clin Med Phys 2017; 18:54-63. [PMID: 28730652 PMCID: PMC5874990 DOI: 10.1002/acm2.12132] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Revised: 05/17/2017] [Accepted: 05/22/2017] [Indexed: 11/07/2022] Open
Abstract
Purpose The aim of this study was to find an optimized configuration of collimator angle, couch angle, and starting tracking phase to improve the delivery performance in terms of MLC position errors, maximal MLC leaf speed, and total beam‐on time of DCAT plans with motion tracking (4D DCAT). Method and materials Nontracking conformal arc plans were first created based on a single phase (maximal exhalation phase) of a respiratory motion phantom with a spherical target. An ideal model was used to simulate the target motion in superior‐inferior (SI), anterior‐posterior (AP), and left‐right (LR) dimensions. The motion was decomposed to the MLC leaf position coordinates for motion compensation and generating 4D DCAT plans. The plans were studied with collimator angle ranged from 0° to 90°; couch angle ranged from 350°(−10°) to 10°; and starting tracking phases at maximal inhalation (θ=π/2) and exhalation (θ=0) phases. Plan performance score (PPS) evaluates the plan complexity including the variability in MLC leaf positions, degree of irregularity in field shape and area. PPS ranges from 0 to 1, where low PPS indicates a plan with high complexity. The 4D DCAT plans with the maximal and the minimal PPS were selected and delivered on a Varian TrueBeam linear accelerator. Gafchromic‐EBT3 dosimetry films were used to measure the dose delivered to the target in the phantom. Gamma analysis for film measurements with 90% passing rate threshold using 3%/3 mm criteria and trajectory log files were analyzed for plan delivery accuracy evaluation. Results The maximal PPS of all the plans was 0.554, achieved with collimator angle at 87°, couch angle at 350°, and starting phase at maximal inhalation (θ=π/2). The maximal MLC leaf speed, MLC leaf errors, total leaf travel distance, and beam‐on time were 20 mm/s, 0.39 ± 0.16 mm, 1385 cm, and 157 s, respectively. The starting phase, whether at maximal inhalation or exhalation had a relatively small contribution to PPS (0.01 ± 0.05). Conclusions By selecting collimator angle, couch angle, and starting tracking phase, 4D DCAT plans with the maximal PPS demonstrated less MLC leaf position errors, lower maximal MLC leaf speed, and shorter beam‐on time which improved the performance of 4D motion‐tracking DCAT delivery.
Collapse
Affiliation(s)
- Zhengzheng Xu
- Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY, USA.,Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, NY, USA
| | - Rutao Yao
- Department of Nuclear Medicine, State University of New York at Buffalo, Buffalo, NY, USA.,Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, NY, USA
| | - Matthew B Podgorsak
- Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY, USA.,Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, NY, USA
| | - Iris Z Wang
- Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY, USA.,Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, NY, USA
| |
Collapse
|
23
|
Yoganathan SA, Maria Das KJ, Agarwal A, Kumar S. Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review. J Med Phys 2017; 42:101-115. [PMID: 28974854 PMCID: PMC5618455 DOI: 10.4103/jmp.jmp_22_17] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 05/31/2017] [Accepted: 07/11/2017] [Indexed: 12/11/2022] Open
Abstract
Tumors in thoracic and upper abdomen regions such as lungs, liver, pancreas, esophagus, and breast move due to respiration. Respiration-induced motion introduces uncertainties in radiotherapy treatments of these sites and is regarded as a significant bottleneck in achieving highly conformal dose distributions. Recent developments in radiation therapy have resulted in (i) motion-encompassing, (ii) respiratory gating, and (iii) tracking methods for adapting the radiation beam aperture to account for the respiration-induced target motion. The purpose of this review is to discuss the magnitude, impact, and management of respiration-induced tumor motion.
Collapse
Affiliation(s)
- S. A. Yoganathan
- Department of Radiotherapy, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - K. J. Maria Das
- Department of Radiotherapy, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Arpita Agarwal
- Department of Radiotherapy, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Shaleen Kumar
- Department of Radiotherapy, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| |
Collapse
|
24
|
Liu Y, Yin FF, Czito BG, Bashir MR, Palta M, Cai J. Retrospective four-dimensional magnetic resonance imaging with image-based respiratory surrogate: a sagittal-coronal-diaphragm point of intersection motion tracking method. J Med Imaging (Bellingham) 2017; 4:024007. [PMID: 28653014 DOI: 10.1117/1.jmi.4.2.024007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Accepted: 06/01/2017] [Indexed: 11/14/2022] Open
Abstract
A four-dimensional magnetic resonance imaging (4-D-MRI) technique with Sagittal-Coronal-Diaphragm Point-of-Intersection (SCD-PoI) as a respiratory surrogate is proposed. To develop an image-based respiratory surrogate, the SCD-PoI motion tracking method is used for retrospective 4-D-MRI reconstruction. Single-slice sagittal MR cine was acquired at a location near the center of the diaphragmatic dome. Multiple-slice coronal MR cines were acquired for 4-D-MRI reconstruction. As a motion surrogate, the diaphragm motion was measured from the PoI among the sagittal MRI cine plane, coronal MRI cine planes, and the diaphragm surface. These points were defined as the SCD-PoI. This point is used as a one-dimensional diaphragmatic navigator in our study. The 4-D-MRI technique was evaluated on a 4-D digital extended cardiac-torso (XCAT) human phantom, a motion phantom, and seven human subjects (five healthy volunteers and two cancer patients). Motion trajectories of a selected region of interest were measured on 4-D-MRI and compared with the known XCAT motion that served as references. The mean absolute amplitude difference ([Formula: see text]) and the cross-correlation coefficient (CC) of the comparisons were determined. 4-D-MRI of the XCAT phantom demonstrated highly accurate motion information ([Formula: see text], [Formula: see text]). Motion trajectories of the motion phantom measured on 4-D-MRI matched well with the references ([Formula: see text], [Formula: see text]). 4-D-MRI of human subjects showed minimal artifacts and clearly revealed the respiratory motion of organs and tumor (mean [Formula: see text]; mean [Formula: see text]). A 4-D-MRI technique with image-based respiratory surrogate has been developed and tested on phantoms and human subjects.
Collapse
Affiliation(s)
- Yilin Liu
- Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States
| | - Fang-Fang Yin
- Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States
| | - Brian G Czito
- Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States
| | - Mustafa R Bashir
- Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States.,Duke University Medical Center, Center for Advanced Magnetic Resonance Development, Durham, North Carolina, United States
| | - Manisha Palta
- Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States
| | - Jing Cai
- Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina, United States
| |
Collapse
|
25
|
Brandner ED, Chetty IJ, Giaddui TG, Xiao Y, Huq MS. Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. Med Phys 2017; 44:2595-2612. [PMID: 28317123 DOI: 10.1002/mp.12227] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 01/23/2017] [Accepted: 03/10/2017] [Indexed: 12/11/2022] Open
Abstract
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated. However, it presents unique challenges for accurate planning and delivery especially in the lungs and upper abdomen where respiratory motion can be significantly confounding accurate targeting and avoidance of normal tissues. In this paper, we review the current literature on SBRT for lung and upper abdominal tumors with particular emphasis on addressing respiratory motion and its affects. We provide recommendations on strategies to manage motion for different, patient-specific situations. Some of the recommendations will potentially be adopted to guide clinical trial protocols.
Collapse
Affiliation(s)
- Edward D Brandner
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| | - Indrin J Chetty
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, 48202, USA
| | - Tawfik G Giaddui
- Sidney Kimmel Cancer Center, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, 19107, USA
| | - Ying Xiao
- Imaging and Radiation Oncology Core (IROC), University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| |
Collapse
|
26
|
Paganelli C, Summers P, Gianoli C, Bellomi M, Baroni G, Riboldi M. A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site. Med Biol Eng Comput 2017; 55:2001-2014. [DOI: 10.1007/s11517-017-1646-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2016] [Accepted: 03/25/2017] [Indexed: 12/18/2022]
|
27
|
Demoor-Goldschmidt C, Chiavassa S, Josset S, Mahé MA, Supiot S. Respiratory-gated bilateral pulmonary radiotherapy for Ewing's sarcoma and nephroblastoma in children and young adults: Dosimetric and clinical feasibility studies. Cancer Radiother 2017; 21:124-129. [PMID: 28377061 DOI: 10.1016/j.canrad.2016.11.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 10/26/2016] [Accepted: 11/02/2016] [Indexed: 11/17/2022]
Abstract
PURPOSE Bilateral pulmonary radiotherapy in children and young adults aims to reduce the recurrence of lung metastases. The radiation field includes liver tissue, which is sensitive to even low radiation doses. We investigated the feasibility of respiratory gating radiotherapy using voluntary deep inspiration breath hold and its toxicity in these patients. PATIENTS AND METHOD A retrospective clinical review was conducted for all patients who had undergone bilateral pulmonary radiotherapy, with or without deep inspiration breath hold, treated in our institution between October 1999 and May 2012. A dosimetric study was conducted on seven consecutive children using 4D-scan data on free-breathing and a SpiroDyn'RX-system-scan on deep inspiration breath hold. A radiation treatment of 20Gy was simulated. RESULTS Concerning the clinical study, seven patients of mean age 11.9 years (range: 4.9-21.1 years) were treated with free-breathing and ten patients of mean age 15.6 years (range: 8.6-19.7 years) were treated with deep inspiration breath hold for mainly Ewing sarcoma and nephroblastoma. Within six months of radiotherapy, all patients experienced mild liver toxicity (grade 1 or 2 altered levels of alanine/aspartate aminotransferase [n=8 of 9] or cholestasis [n=1 of 9]), which resolved completely with no difference between deep inspiration breath hold and free-breathing technique. Over a median follow-up of 2.6 years (range: 0.1-9.3 years), four patients died from disease progression (mean 1.5 years post-radiotherapy [range: 1.1-1.6 years]) and three experienced grade III-V lung toxicity. Concerning the dosimetric study, the irradiated liver volume was significantly lower with deep inspiration breath hold than free-breathing, for each isodose (V5: 73.80% versus 86.74%, P<0.05; V20: 5.70% versus 26.44%, P<0.05). CONCLUSIONS The dosimetric data of respiratory-gated bilateral pulmonary radiotherapy showed a significantly spare of normal liver tissue. Clinical data showed that this technique is feasible even in young children. However, no liver toxicity difference between deep inspiration breath hold and free-breathing was shown.
Collapse
Affiliation(s)
- C Demoor-Goldschmidt
- Department of radiation oncology, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain, France; Faculté de médecine, université de Nantes, 1, rue Gaston-Veil, 44000 Nantes, France; Centre de recherche en épidémiologie et santé publique (CESP), 114, rue Édouard-Vaillant, 94805 Villejuif, France; Inserm U1018, 114, rue Édouard-Vaillant, 94805 Villejuif, France; Université Paris-Saclay, université Paris-Sud, 94807 Villejuif, France; Department of clinical research, Gustave-Roussy, 114, rue Édouard-Vaillant, 94805 Villejuif, France.
| | - S Chiavassa
- Department of medical physics, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain, France
| | - S Josset
- Department of medical physics, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain, France
| | - M-A Mahé
- Department of radiation oncology, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain, France; Faculté de médecine, université de Nantes, 1, rue Gaston-Veil, 44000 Nantes, France
| | - S Supiot
- Department of radiation oncology, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint-Herblain, France; Faculté de médecine, université de Nantes, 1, rue Gaston-Veil, 44000 Nantes, France
| |
Collapse
|
28
|
Sarudis S, Karlsson Hauer A, Nyman J, Bäck A. Systematic evaluation of lung tumor motion using four-dimensional computed tomography. Acta Oncol 2017; 56:525-530. [PMID: 28075183 DOI: 10.1080/0284186x.2016.1274049] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Respiratory-induced lung tumor motion may decrease robustness and outcome of radiation therapy (RT) if not accounted for. This study provides detailed information on the motion distribution of lung tumors for a group of 126 patients treated with stereotactic body RT. MATERIAL AND METHODS Four-dimensional computed tomography scans were reviewed to assess lung tumor motion. The tumor motion was determined by the center of mass shift based on a rigid registration of the breathing phases containing the largest positional differences in the inferior-superior (IS), left-right (LR), and anterior-posterior (AP) directions. The patients were divided into subgroups depending on tumor diameter (φ < 2.0 cm, 2.0 ≤ φ ≤ 5.0 cm, φ > 5.0 cm) and tumor location within the lung (upper, middle, or lower lobe). The observed motion distributions were evaluated for each group separately to assess the dependence on tumor size and location. For each tumor size, the motion pattern in each direction (IS, LR, and AP) was analyzed for every tumor moving >5 mm. Sinusoidal trigonometric functions were fitted to the measured data using the least mean square method to determine which type of function best describes the motion pattern. Tumor volumes between 1.6 and 52.3 cm3 were evaluated. Mann-Whitney statistical tests were used for statistical analyses. RESULTS The mean amplitude for the tumors in this study was 1.5 mm (LR), 2.5 mm (AP), and 6.9 mm (IS) while the maximum amplitude was 11.0 mm (LR), 9.0 mm (AP), and 53.0 mm (IS). In total, 95% of the tumors moved ≤20 mm in the IS direction, ≤3 mm in the LR direction, and ≤6 mm in the AP direction. The observed motion distributions showed no statistically significant correlation with tumor size or location within the lung except for motion in the IS direction, where the mean and maximum amplitudes significantly increased for tumors located in the middle and lower parts of the lung. The motion pattern of a tumor in any direction was best described using a squared trigonometric function of the type [Formula: see text], where A is the maximum amplitude of the motion in the current direction, t is the time of measurement, T is the total time of the breathing cycle and B is a constant used to synchronize the starting point of the breathing cycle. CONCLUSION Lung tumor movements were generally larger in the IS direction and the motion amplitude in this direction increased for tumors located in the middle and lower parts of the lungs. Motions in LR or AP showed no such relation. Tumor size was not found to have any correlation with the motion amplitude in any direction. The motion pattern of a lung tumor in any direction is best described with a squared sinusoidal function independently of the tumor size or tumor location.
Collapse
Affiliation(s)
- Sebastian Sarudis
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Borås, Sweden
- Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anna Karlsson Hauer
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Jan Nyman
- Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anna Bäck
- Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
29
|
Ahmed N, Venkataraman S, Johnson K, Sutherland K, Loewen SK. Does Motion Assessment With 4-Dimensional Computed Tomographic Imaging for Non-Small Cell Lung Cancer Radiotherapy Improve Target Volume Coverage? CLINICAL MEDICINE INSIGHTS-ONCOLOGY 2017; 11:1179554917698461. [PMID: 28469512 PMCID: PMC5395259 DOI: 10.1177/1179554917698461] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2016] [Accepted: 02/12/2017] [Indexed: 12/25/2022]
Abstract
Introduction: Modern radiotherapy with 4-dimensional computed tomographic (4D-CT) image acquisition for non–small cell lung cancer (NSCLC) captures respiratory-mediated tumor motion to provide more accurate target delineation. This study compares conventional 3-dimensional (3D) conformal radiotherapy (3DCRT) plans generated with standard helical free-breathing CT (FBCT) with plans generated on 4D-CT contoured volumes to determine whether target volume coverage is affected. Materials and methods: Fifteen patients with stage I to IV NSCLC were enrolled in the study. Free-breathing CT and 4D-CT data sets were acquired at the same simulation session and with the same immobilization. Gross tumor volume (GTV) for primary and/or nodal disease was contoured on FBCT (GTV_3D). The 3DCRT plans were obtained, and the patients were treated according to our institution’s standard protocol using FBCT imaging. Gross tumor volume was contoured on 4D-CT for primary and/or nodal disease on all 10 respiratory phases and merged to create internal gross tumor volume (IGTV)_4D. Clinical target volume margin was 5 mm in both plans, whereas planning tumor volume (PTV) expansion was 1 cm axially and 1.5 cm superior/inferior for FBCT-based plans to incorporate setup errors and an estimate of respiratory-mediated tumor motion vs 8 mm isotropic margin for setup error only in all 4D-CT plans. The 3DCRT plans generated from the FBCT scan were copied on the 4D-CT data set with the same beam parameters. GTV_3D, IGTV_4D, PTV, and dose volume histogram from both data sets were analyzed and compared. Dice coefficient evaluated PTV similarity between FBCT and 4D-CT data sets. Results: In total, 14 of the 15 patients were analyzed. One patient was excluded as there was no measurable GTV. Mean GTV_3D was 115.3 cm3 and mean IGTV_4D was 152.5 cm3 (P = .001). Mean PTV_3D was 530.0 cm3 and PTV_4D was 499.8 cm3 (P = .40). Both gross primary and nodal disease analyzed separately were larger on 4D compared with FBCT. D95 (95% isodose line) covered 98% of PTV_3D and 88% of PTV_4D (P = .003). Mean dice coefficient of PTV_3D and PTV_4D was 84%. Mean lung V20 was 24.0% for the 3D-based plans and 22.7% for the 4D-based plans (P = .057). Mean heart V40 was 12.1% for the 3D-based plans and 12.7% for the 4D-based plans (P = .53). Mean spinal cord Dmax was 2517 and 2435 cGy for 3D-based and 4D-based plans, respectively (P = .019). Mean esophageal dose was 1580 and 1435 cGy for 3D and 4D plans, respectively (P = .13). Conclusions: IGTV_4D was significantly larger than GTV_3D for both primary and nodal disease combined or separately. Mean PTV_3D was larger than PTV_4D, but the difference was not statistically significant. The PTV_4D coverage with 95% isodose line was inferior, indicating the importance of incorporating the true size and shape of the target volume. Relatively less dose was delivered to spinal cord and esophagus with plans based on 4D data set. Dice coefficient analysis for degree of similarity revealed that 16% of PTVs from both data sets did not overlap, indicating different anatomical positions of the PTV due to tumor/nodal motion during a respiratory cycle. All patients with lung cancer planned for radical radiotherapy should have 4D-CT simulation to ensure accurate coverage of the target volumes.
Collapse
Affiliation(s)
- Naseer Ahmed
- Department of Radiation Oncology, CancerCare Manitoba, Winnipeg, MB, Canada.,Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Sankar Venkataraman
- Department of Radiation Oncology, CancerCare Manitoba, Winnipeg, MB, Canada.,Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Kate Johnson
- Department of Radiation Oncology, CancerCare Manitoba, Winnipeg, MB, Canada.,Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Keith Sutherland
- Department of Radiation Oncology, CancerCare Manitoba, Winnipeg, MB, Canada
| | - Shaun K Loewen
- Division of Radiation Oncology, Department of Radiation Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
30
|
Arai TJ, Nofiele J, Madhuranthakam AJ, Yuan Q, Pedrosa I, Chopra R, Sawant A. Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy. Med Phys 2017; 43:2807-2820. [PMID: 27277029 DOI: 10.1118/1.4948684] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of "true" information due to greater reliance on a priori information. METHODS Lung tumor motion trajectories in the superior-inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. RESULTS In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3-0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. CONCLUSIONS The authors' initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.
Collapse
Affiliation(s)
- Tatsuya J Arai
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Joris Nofiele
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Qing Yuan
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Ivan Pedrosa
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390 and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390
| | - Amit Sawant
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75390; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas 75390; and Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, 21201
| |
Collapse
|
31
|
Glitzner M, Fast MF, de Senneville BD, Nill S, Oelfke U, Lagendijk JJW, Raaymakers BW, Crijns SPM. Real-time auto-adaptive margin generation for MLC-tracked radiotherapy. Phys Med Biol 2017; 62:186-201. [PMID: 27991457 PMCID: PMC5952335 DOI: 10.1088/1361-6560/62/1/186] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 10/16/2016] [Accepted: 11/09/2016] [Indexed: 11/12/2022]
Abstract
In radiotherapy, abdominal and thoracic sites are candidates for performing motion tracking. With real-time control it is possible to adjust the multileaf collimator (MLC) position to the target position. However, positions are not perfectly matched and position errors arise from system delays and complicated response of the electromechanic MLC system. Although, it is possible to compensate parts of these errors by using predictors, residual errors remain and need to be compensated to retain target coverage. This work presents a method to statistically describe tracking errors and to automatically derive a patient-specific, per-segment margin to compensate the arising underdosage on-line, i.e. during plan delivery. The statistics of the geometric error between intended and actual machine position are derived using kernel density estimators. Subsequently a margin is calculated on-line according to a selected coverage parameter, which determines the amount of accepted underdosage. The margin is then applied onto the actual segment to accommodate the positioning errors in the enlarged segment. The proof-of-concept was tested in an on-line tracking experiment and showed the ability to recover underdosages for two test cases, increasing [Formula: see text] in the underdosed area about [Formula: see text] and [Formula: see text], respectively. The used dose model was able to predict the loss of dose due to tracking errors and could be used to infer the necessary margins. The implementation had a running time of 23 ms which is compatible with real-time requirements of MLC tracking systems. The auto-adaptivity to machine and patient characteristics makes the technique a generic yet intuitive candidate to avoid underdosages due to MLC tracking errors.
Collapse
Affiliation(s)
- M Glitzner
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - M F Fast
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - B Denis de Senneville
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
- Mathematical Institute of Bordeaux, UMR 5251 CNRS/University of Bordeaux, 33405 Talence Cedex, France
| | - S Nill
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - U Oelfke
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - J J W Lagendijk
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - B W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - S P M Crijns
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
32
|
Ter Voert EEGW, Heijmen L, Punt CJA, de Wilt JHW, van Laarhoven HWM, Heerschap A. Reduced respiratory motion artifacts using structural similarity in fast 2D dynamic contrast enhanced MRI of liver lesions. NMR IN BIOMEDICINE 2016; 29:1526-1535. [PMID: 27598946 DOI: 10.1002/nbm.3606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 07/21/2016] [Accepted: 07/25/2016] [Indexed: 06/06/2023]
Abstract
The purpose of this work was to improve dynamic contrast enhanced MRI (DCE-MRI) of liver lesions by removing motion corrupted images as identified by a structural similarity (SSIM) algorithm, and to assess the effect of this correction on the pharmacokinetic parameter Ktrans using automatically determined arterial input functions (AIFs). Fifteen patients with colorectal liver metastases were measured twice with a T1 weighted multislice 2D FLASH sequence for DCE-MRI (time resolution 1.2 s). AIFs were automatically derived from contrast inflow in the aorta of each patient. Thereafter, SSIM identified motion corrupted images of the liver were removed from the DCE dataset. From this corrected data set Ktrans and its reproducibility were determined. Using the SSIM algorithm a median fraction of 46% (range 37-50%) of the liver images in DCE time series was labeled as motion distorted. Rejection of these images resulted in a significantly lower median Ktrans (p < 0.05) and lower coefficient of repeatability of Ktrans in liver metastases compared with an analysis without correction. SSIM correction improves the reproducibility of the DCE-MRI parameter Ktrans in liver metastasis and reduces contamination of Ktrans values of lesions by that of surrounding normal liver tissue.
Collapse
Affiliation(s)
- Edwin E G W Ter Voert
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
| | - Linda Heijmen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
- Department of Medical Oncology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Cornelis J A Punt
- Department of Medical Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Johannes H W de Wilt
- Department of Surgery, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Hanneke W M van Laarhoven
- Department of Medical Oncology, Radboud University Medical Center, Nijmegen, The Netherlands
- Department of Medical Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Arend Heerschap
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
33
|
Bourque AE, Bedwani S, Filion É, Carrier JF. A particle filter based autocontouring algorithm for lung tumor tracking using dynamic magnetic resonance imaging. Med Phys 2016; 43:5161. [DOI: 10.1118/1.4961403] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
34
|
Abstract
Computed tomography is the first-line modality for evaluation of chest diseases primarily because of its spatial resolution. Magnetic resonance (MR) imaging is used as a problem-solving tool to answer key questions that are vital to optimal patient management. MR has the potential to provide qualitative, quantitative, anatomic, and functional information without the use of ionizing radiation or nephrotoxic contrast administration. With new advances in proton MR techniques, MR imaging can overcome some of the inherent problems associated with imaging the lung. This article describes novel MR applications for evaluation of the pleura and pleural diseases.
Collapse
|
35
|
Kumar S, Liney G, Rai R, Holloway L, Moses D, Vinod SK. Magnetic resonance imaging in lung: a review of its potential for radiotherapy. Br J Radiol 2016; 89:20150431. [PMID: 26838950 DOI: 10.1259/bjr.20150431] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
MRI has superior soft-tissue definition compared with existing imaging modalities in radiation oncology; this has the added benefit of functional as well as anatomical imaging. This review aimed to evaluate the current use of MRI for lung cancer and identify the potential of a MRI protocol for lung radiotherapy (RT). 30 relevant studies were identified. Improvements in MRI technology have overcome some of the initial limitations of utilizing MRI for lung imaging. A number of commercially available and novel sequences have shown image quality to be adequate for the detection of pulmonary nodules with the potential for tumour delineation. Quantifying tumour motion is also feasible and may be more representative than that seen on four-dimensional CT. Functional MRI sequences have shown correlation with flu-deoxy-glucose positron emission tomography (FDG-PET) in identifying malignant involvement and treatment response. MRI can also be used as a measure of pulmonary function. While there are some limitations for the adoption of MRI in RT-planning process for lung cancer, MRI has shown the potential to compete with both CT and PET for tumour delineation and motion definition, with the added benefit of functional information. MRI is well placed to become a significant imaging modality in RT for lung cancer.
Collapse
Affiliation(s)
- Shivani Kumar
- 1 South Western Clinical School, School of Medicine, University of New South Wales, Liverpool, NSW, Australia.,2 Liverpool and Macarthur Cancer Therapy Centres, Liverpool Hospital, Liverpool, NSW, Australia.,3 Ingham Institute of Applied Medical Research, Liverpool, NSW, Australia
| | - Gary Liney
- 1 South Western Clinical School, School of Medicine, University of New South Wales, Liverpool, NSW, Australia.,2 Liverpool and Macarthur Cancer Therapy Centres, Liverpool Hospital, Liverpool, NSW, Australia.,3 Ingham Institute of Applied Medical Research, Liverpool, NSW, Australia.,4 Centre for Medical Radiation Physics, University of Wollongong, Liverpool, NSW, Australia
| | - Robba Rai
- 2 Liverpool and Macarthur Cancer Therapy Centres, Liverpool Hospital, Liverpool, NSW, Australia.,3 Ingham Institute of Applied Medical Research, Liverpool, NSW, Australia
| | - Lois Holloway
- 1 South Western Clinical School, School of Medicine, University of New South Wales, Liverpool, NSW, Australia.,2 Liverpool and Macarthur Cancer Therapy Centres, Liverpool Hospital, Liverpool, NSW, Australia.,3 Ingham Institute of Applied Medical Research, Liverpool, NSW, Australia.,4 Centre for Medical Radiation Physics, University of Wollongong, Liverpool, NSW, Australia.,5 Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Daniel Moses
- 1 South Western Clinical School, School of Medicine, University of New South Wales, Liverpool, NSW, Australia.,6 Department of Medical Imaging, Northern Hospital Network, Sydney, NSW, Australia.,7 Western Sydney University, Penrith, NSW, Australia
| | - Shalini K Vinod
- 1 South Western Clinical School, School of Medicine, University of New South Wales, Liverpool, NSW, Australia.,2 Liverpool and Macarthur Cancer Therapy Centres, Liverpool Hospital, Liverpool, NSW, Australia.,7 Western Sydney University, Penrith, NSW, Australia
| |
Collapse
|
36
|
Seregni M, Paganelli C, Lee D, Greer PB, Baroni G, Keall PJ, Riboldi M. Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI. Phys Med Biol 2016; 61:872-87. [DOI: 10.1088/0031-9155/61/2/872] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
37
|
Seyfi B, Santhanam AP, Ilegbusi OJ. A Biomechanical Model of Human Lung Deformation Utilizing Patient-Specific Elastic Property. ACTA ACUST UNITED AC 2016. [DOI: 10.4236/jct.2016.76043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
38
|
Kumagai M, Mori S. Movement of a small tumour in contact with the diaphragm: characterisation with four-dimensional CT. Jpn J Radiol 2015; 34:154-7. [DOI: 10.1007/s11604-015-0509-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 11/27/2015] [Indexed: 12/25/2022]
|
39
|
Abstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Collapse
Affiliation(s)
- Maria A Schmidt
- Cancer Research UK Cancer Imaging Centre, Royal Marsden Hospital and the Institute of Cancer Research, Downs Road, Sutton, Surrey, SM2 5PT, UK
| | | |
Collapse
|
40
|
Paganelli C, Lee D, Greer PB, Baroni G, Riboldi M, Keall P. Quantification of lung tumor rotation with automated landmark extraction using orthogonal cine MRI images. Phys Med Biol 2015; 60:7165-78. [DOI: 10.1088/0031-9155/60/18/7165] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
41
|
Ilegbusi O, Seyfi B, Neylon J, Santhanam AP. Analytic Intermodel Consistent Modeling of Volumetric Human Lung Dynamics. J Biomech Eng 2015; 137:101005. [PMID: 26292034 DOI: 10.1115/1.4031349] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Indexed: 12/25/2022]
Abstract
Human lung undergoes breathing-induced deformation in the form of inhalation and exhalation. Modeling the dynamics is numerically complicated by the lack of information on lung elastic behavior and fluid-structure interactions between air and the tissue. A mathematical method is developed to integrate deformation results from a deformable image registration (DIR) and physics-based modeling approaches in order to represent consistent volumetric lung dynamics. The computational fluid dynamics (CFD) simulation assumes the lung is a poro-elastic medium with spatially distributed elastic property. Simulation is performed on a 3D lung geometry reconstructed from four-dimensional computed tomography (4DCT) dataset of a human subject. The heterogeneous Young's modulus (YM) is estimated from a linear elastic deformation model with the same lung geometry and 4D lung DIR. The deformation obtained from the CFD is then coupled with the displacement obtained from the 4D lung DIR by means of the Tikhonov regularization (TR) algorithm. The numerical results include 4DCT registration, CFD, and optimal displacement data which collectively provide consistent estimate of the volumetric lung dynamics. The fusion method is validated by comparing the optimal displacement with the results obtained from the 4DCT registration.
Collapse
|
42
|
Mayer R, Liacouras P, Thomas A, Kang M, Lin L, Simone CB. 3D printer generated thorax phantom with mobile tumor for radiation dosimetry. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:074301. [PMID: 26233396 DOI: 10.1063/1.4923294] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor's trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.
Collapse
Affiliation(s)
- Rulon Mayer
- Henry Jackson Foundation, Bethesda, Maryland 20817, USA
| | - Peter Liacouras
- Walter Reed National Military Medical Center, Bethesda, Maryland 20899, USA
| | - Andrew Thomas
- ATC Healthcare, Washington, District of Columbia 20006, USA
| | - Minglei Kang
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | - Liyong Lin
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | - Charles B Simone
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| |
Collapse
|
43
|
Gou S, Wang Y, Wu J, Lee P, Sheng K. Lung dynamic MRI deblurring using low-rank decomposition and dictionary learning. Med Phys 2015; 42:1917-25. [PMID: 25832082 DOI: 10.1118/1.4915543] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
PURPOSE Lung dynamic MRI (dMRI) has emerged to be an appealing tool to quantify lung motion for both planning and treatment guidance purposes. However, this modality can result in blurry images due to intrinsically low signal-to-noise ratio in the lung and spatial/temporal interpolation. The image blurring could adversely affect the image processing that depends on the availability of fine landmarks. The purpose of this study is to reduce dMRI blurring using image postprocessing. METHODS To enhance the image quality and exploit the spatiotemporal continuity of dMRI sequences, a low-rank decomposition and dictionary learning (LDDL) method was employed to deblur lung dMRI and enhance the conspicuity of lung blood vessels. Fifty frames of continuous 2D coronal dMRI frames using a steady state free precession sequence were obtained from five subjects including two healthy volunteer and three lung cancer patients. In LDDL, the lung dMRI was decomposed into sparse and low-rank components. Dictionary learning was employed to estimate the blurring kernel based on the whole image, low-rank or sparse component of the first image in the lung MRI sequence. Deblurring was performed on the whole image sequences using deconvolution based on the estimated blur kernel. The deblurring results were quantified using an automated blood vessel extraction method based on the classification of Hessian matrix filtered images. Accuracy of automated extraction was calculated using manual segmentation of the blood vessels as the ground truth. RESULTS In the pilot study, LDDL based on the blurring kernel estimated from the sparse component led to performance superior to the other ways of kernel estimation. LDDL consistently improved image contrast and fine feature conspicuity of the original MRI without introducing artifacts. The accuracy of automated blood vessel extraction was on average increased by 16% using manual segmentation as the ground truth. CONCLUSIONS Image blurring in dMRI images can be effectively reduced using a low-rank decomposition and dictionary learning method using kernels estimated by the sparse component.
Collapse
Affiliation(s)
- Shuiping Gou
- Key Lab of Intelligent Perception and Image Understanding of Ministry of Education, Xidian University, Xi'an, Shaanxi 710071, China and Department of Radiation Oncology, University of California, Los Angeles, California 90095
| | - Yueyue Wang
- Key Lab of Intelligent Perception and Image Understanding of Ministry of Education, Xidian University, Xi'an, Shaanxi 710071, China
| | - Jiaolong Wu
- Key Lab of Intelligent Perception and Image Understanding of Ministry of Education, Xidian University, Xi'an, Shaanxi 710071, China
| | - Percy Lee
- Department of Radiation Oncology, University of California, Los Angeles, California 90095
| | - Ke Sheng
- Department of Radiation Oncology, University of California, Los Angeles, California 90095
| |
Collapse
|
44
|
Yang J, Wang H, Yin Y, Li D. Retracted: Reducing motion artifacts in 4D MR images using principal component analysis (PCA) combined with linear polynomial fitting model. J Appl Clin Med Phys 2015; 16:5165. [PMID: 26103185 PMCID: PMC5690092 DOI: 10.1120/jacmp.v16i2.5165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 11/25/2014] [Accepted: 10/24/2014] [Indexed: 11/23/2022] Open
Abstract
We have previously developed a retrospective 4D-MRI technique using body area as the respiratory surrogate, but generally, the reconstructed 4D MR images suffer from severe or mild artifacts mainly caused by irregular motion during image acquisition. Those image artifacts may potentially affect the accuracy of tumor target delineation or the shape representation of surrounding nontarget tissues and organs. So the purpose of this study is to propose an approach employing principal component analysis (PCA), combined with a linear polynomial fitting model, to remodel the displacement vector fields (DVFs) obtained from deformable image registration (DIR), with the main goal of reducing the motion artifacts in 4D MR images. Seven patients with hepatocellular carcinoma (2/7) or liver metastases (5/7) in the liver, as well as a patient with non-small cell lung cancer (NSCLC), were enrolled in an IRB-approved prospective study. Both CT and MR simulations were performed for each patient for treatment planning. Multiple-slice, multiple-phase, cine-MRI images were acquired in the axial plane for 4D-MRI reconstruction. Single-slice 2D cine-MR images were acquired across the center of the tumor in axial, coronal, and sagittal planes. For a 4D MR image dataset, the DVFs in three orthogonal direction (inferior–superior (SI), anterior–posterior (AP), and medial–lateral (ML)) relative to a specific reference phase were calculated using an in-house DIR algorithm. The DVFs were preprocessed in three temporal and spatial dimensions using a polynomial fitting model, with the goal of correcting the potential registration errors introduced by three-dimensional DIR. Then PCA was used to decompose each fitted DVF into a linear combination of three principal motion bases whose spanned subspaces combined with their projections had been validated to be sufficient to represent the regular respiratory motion. By wrapping the reference MR image using the remodeled DVFs, 'synthetic' MR images with reduced motion artifacts were generated at selected phase. Tumor motion trajectories derived from cine-MRI, 4D CT, original 4D MRI, and 'synthetic' 4D MRI were analyzed in the SI, AP, and ML directions, respectively. Their correlation coefficient (CC) and difference (D) in motion amplitude were calculated for comparison. Of all the patients, the means and standard deviations (SDs) of CC comparing 'synthetic' 4D MRI and cine-MRI were 0.98 ± 0.01, 0.98 ± 0.01, and 0.99 ± 0.01 in SI, AP, and ML directions, respectively. The mean ± SD Ds were 0.59 ± 0.09 mm, 0.29± 0.10 mm, and 0.15 ± 0.05 mm in SI, AP and ML directions, respectively. The means and SDs of CC comparing 'synthetic' 4D MRI and 4D CT were 0.96 ± 0.01, 0.95± 0.01, and 0.95 ± 0.01 in SI, AP, and ML directions, respectively. The mean ± SD Ds were 0.76 ± 0.20 mm, 0.33 ± 0.14 mm, and 0.19± 0.07 mm in SI, AP, and ML directions, respectively. The means and SDs of CC comparing 'synthetic' 4D MRI and original 4D MRI were 0.98 ± 0.01, 0.98± 0.01, and 0.97± 0.01 in SI, AP, and ML directions, respectively. The mean ± SD Ds were 0.58 ± 0.10 mm, 0.30 ± 0.09mm, and 0.17 ± 0.04 mm in SI, AP, and ML directions, respectively. In this study we have proposed an approach employing PCA combined with a linear polynomial fitting model to capture the regular respiratory motion from a 4D MR image dataset. And its potential usefulness in reducing motion artifacts and improving image quality has been demonstrated by the preliminary results in oncological patients.
Collapse
|
45
|
Martin S, Johnson C, Brophy M, Palma DA, Barron JL, Beauchemin SS, Louie AV, Yu E, Yaremko B, Ahmad B, Rodrigues GB, Gaede S. Impact of target volume segmentation accuracy and variability on treatment planning for 4D-CT-based non-small cell lung cancer radiotherapy. Acta Oncol 2015; 54:322-32. [PMID: 25350526 DOI: 10.3109/0284186x.2014.970666] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Accurate target volume segmentation is crucial for success in image-guided radiotherapy. However, variability in anatomical segmentation is one of the most significant contributors to uncertainty in radiotherapy treatment planning. This is especially true for lung cancer where target volumes are subject to varying magnitudes of respiratory motion. MATERIAL AND METHODS This study aims to analyze multiple observer target volume segmentations and subsequent intensity-modulated radiotherapy (IMRT) treatment plans defined by those segmentations against a reference standard for lung cancer patients imaged with four-dimensional computed tomography (4D-CT). Target volume segmentations of 10 patients were performed manually by six physicians, allowing for the calculation of ground truth estimate segmentations via the simultaneous truth and performance level estimation (STAPLE) algorithm. Segmentation variability was assessed in terms of distance- and volume-based metrics. Treatment plans defined by these segmentations were then subject to dosimetric evaluation consisting of both physical and radiobiological analysis of optimized 3D dose distributions. RESULTS Significant differences were noticed amongst observers in comparison to STAPLE segmentations and this variability directly extended into the treatment planning stages in the context of all dosimetric parameters used in this study. Mean primary tumor control probability (TCP) ranged from (22.6±11.9)% to (33.7±0.6)%, with standard deviation ranging from 0.5% to 11.9%. However, mean normal tissue complication probabilities (NTCP) based on treatment plans for each physician-derived target volume well as the NTCP derived from STAPLE-based treatment plans demonstrated no discernible trends and variability appeared to be patient-specific. This type of variability demonstrated the large-scale impact that target volume segmentation uncertainty can play in IMRT treatment planning. CONCLUSIONS Significant target volume segmentation and dosimetric variability exists in IMRT treatment planning amongst experts in the presence of a reference standard for 4D-CT-based lung cancer radiotherapy. Future work is needed to mitigate this uncertainty and ensure highly accurate and effective radiotherapy for lung cancer patients.
Collapse
Affiliation(s)
- Spencer Martin
- Department of Medical Biophysics, University of Western Ontario , London, Ontario , Canada
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study. Int J Radiat Oncol Biol Phys 2015; 91:840-8. [DOI: 10.1016/j.ijrobp.2014.12.013] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 10/14/2014] [Accepted: 12/08/2014] [Indexed: 12/25/2022]
|
47
|
Martin S, Brophy M, Palma D, Louie AV, Yu E, Yaremko B, Ahmad B, Barron JL, Beauchemin SS, Rodrigues G, Gaede S. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging. Phys Med Biol 2015; 60:1497-518. [DOI: 10.1088/0031-9155/60/4/1497] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
48
|
Are therapeutic radiographers able to achieve clinically acceptable verification for stereotactic lung radiotherapy treatment (SBRT)? JOURNAL OF RADIOTHERAPY IN PRACTICE 2015. [DOI: 10.1017/s1460396914000478] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurposeThe aim of this study was to assess the feasibility of radiographer led verification of cone-beam computed tomography (CBCT) images for patients with solitary lung tumours treated with stereotactic body radiotherapy treatment (SBRT).Material and methodsCBCT setup images of 20 patients from the first fraction of each patient were retrospectively registered by therapeutic radiographers. The displacements recorded were compared with the clinical oncologist’s original online match. The time taken by radiographers to verify the CBCT images was also recorded.ResultsOverall agreement for all radiographers when compared with the clinical oncologist match was 91%. Interobserver variations between radiographers were X plane 0·87 (0·76–0·94); Y plane 0·74 (0·51–0·88); and Z plane 0·88 (0·78–0·95) intraclass correlation coefficient and 95% confidence interval. The average time taken for verification was 128 seconds.ConclusionTherapeutic radiographers are able to verify CBCT images for thorax SBRT with results comparable to the ‘gold standard’ clinical oncologists’ match, however additional training will be provided for online verification. The time taken was within acceptable limits.
Collapse
|
49
|
Yang J, Yamamoto T, Mazin SR, Graves EE, Keall PJ. The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study. Med Phys 2014; 41:021718. [PMID: 24506609 DOI: 10.1118/1.4861816] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. METHODS The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈ 10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. RESULTS The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. CONCLUSIONS The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.
Collapse
Affiliation(s)
- Jaewon Yang
- Department of Electrical Engineering, Stanford University, Stanford, California 94305 and Department of Radiation Oncology, Stanford University, Stanford, California 94305
| | - Tokihiro Yamamoto
- Department of Radiation Oncology, University of California Davis, Sacramento, California 95817
| | | | - Edward E Graves
- Department of Radiation Oncology, Stanford University, Stanford, California 94305
| | - Paul J Keall
- Radiation Physics Laboratory, University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
50
|
Mori S, Dong L, Starkschall G, Mohan R, Chen GTY. A serial 4DCT study to quantify range variations in charged particle radiotherapy of thoracic cancers. JOURNAL OF RADIATION RESEARCH 2014; 55:309-319. [PMID: 24142967 PMCID: PMC3951076 DOI: 10.1093/jrr/rrt114] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Weekly serial 4DCT scans were acquired under free breathing conditions to assess water-equivalent path length (WEL) variations due to both intrafractional and interfractional changes in tissue thickness and density and to calculate proton dose distributions resulting from anatomical variations observed in serial 4DCT. A template of region of interests (ROIs) was defined on the anterior-posterior (AP) beam's eye view, and WEL measurements were made over these ROIs to quantify chest wall thickness variations. Interfractional proton dose distributions were calculated to assess changes in the expected dose distributions caused by range variations. Mean intrafractional chest wall WEL changes during respiration varied by: -4.1 mm (<-10.2 mm), -3.6 mm (<-7.1 mm), -3.2 mm (<-5.6 mm) and -2.5 mm (<-5.1 mm) during respiration in the ITV, upper, middle and lower lung regions, respectively. The mean interfractional chest wall WEL variation at Week 6 decreased by -4.0 mm (<-8.6 mm), -9.1 mm (<-17.9 mm), -9.4 mm (<-25.3 mm) and -4.5 mm (<-15.6 mm) in the ITV, upper, middle and lower lung regions, respectively. The variations were decomposed into anterior and posterior chest wall thickness changes. Dose overshoot beyond the target was observed when the initial boli was applied throughout the treatment course. This overshoot is due to chest wall thickness variations and target positional variations. The radiological path length can vary significantly during respiration as well as over the course of several weeks of charged particle therapy. Intrafractional/interfractional chest wall thickness changes can be a significant source of range variation in treatment of lung tumors with charged particle beams, resulting in dose distribution perturbations from the initial plan. Consideration of these range variations should be made in choosing the therapeutic charged particle beam range.
Collapse
Affiliation(s)
- Shinichiro Mori
- Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | | | | | | | | |
Collapse
|