1
|
Liu M, Tang B, Orlandini LC, Li J, Wang X, Peng Q, Thwaites D. Potential dosimetric error in the adaptive workflow of a 1.5 T MR-Linac from patient movement relative to immobilisation systems. Phys Eng Sci Med 2024; 47:351-359. [PMID: 38227140 DOI: 10.1007/s13246-023-01369-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 12/10/2023] [Indexed: 01/17/2024]
Abstract
In magnetic resonance- (MR-) based adaptive workflows for an MR-linac, the treatment plan is optimized and recalculated online using the daily MR images. The Unity MR-linac is supplied with a patient positioning device (ppd) using pelvic and abdomen thermoplastic masks attached to a board with high-density components. This study highlights the dosimetric effect of using this in such workflows when there are relative patient-ppd displacements, as these are not visualized on MR imaging and the treatment planning system assumes the patient is fixed relative to the ppd. The online adapted plans of two example rectum cancer patients treated at a Unity MR-linac were perturbed by introducing relative patient-ppd displacements, and the effect was evaluated on plan dosimetry. Forty-eight perturbed clinical adapted plans were recalculated, based on online MR-based synthetic computed tomography, and compared with the original plans, using dose-volume histogram parameters and gamma analysis. The target volume covered by the prescribed dose ( D pre ) and by at least 107% of D pre varied up to - 1.87% and + 3.67%, respectively for 0.5 cm displacements, and to - 3.18% and + 4.96% for 2 cm displacements; whilst 2%-2 mm gamma analysis showed a median value of 92.9%. The use of a patient positioning system with high-density components in a Unity MR-based online adaptive treatment workflow can introduce unrecognized errors in plan dosimetry and it is recommended not to use such a device for such treatments, without modifying the device and the workflow, followed by careful clinical evaluation, or alternatively to use other immobilization methods.
Collapse
Affiliation(s)
- Min Liu
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China
- Institute of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, China
| | - Bin Tang
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China
| | - Lucia Clara Orlandini
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China
| | - Jie Li
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China.
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China.
- Radiotherapy Research Group, Leeds Institute of Medical Research, St James's Hospital and University of Leeds, Leeds, UK.
| | - Xianliang Wang
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China.
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China.
- Radiotherapy Research Group, Leeds Institute of Medical Research, St James's Hospital and University of Leeds, Leeds, UK.
| | - Qian Peng
- Radiation Oncology Department, Sichuan Cancer Hospital & Institute, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China
- Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Chengdu, China
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
- Sydney West Radiation Oncology Network, Crown Princess Mary Cancer Centre, Sydney, NSW, Australia
- Radiotherapy Research Group, Leeds Institute of Medical Research, St James's Hospital and University of Leeds, Leeds, UK
| |
Collapse
|
2
|
Ben Bouchta Y, Gardner M, Sengupta C, Johnson J, Keall P. The Remove-the-Mask Open-Source head and neck Surface-Guided radiation therapy system. Phys Imaging Radiat Oncol 2024; 29:100541. [PMID: 38327762 PMCID: PMC10847032 DOI: 10.1016/j.phro.2024.100541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 12/22/2023] [Accepted: 01/24/2024] [Indexed: 02/09/2024] Open
Abstract
Background and Purpose Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 ± 0.4 mm -0.6 ± 0.6 mm and 0.3 ± 0.2 mm, and 0.0 ± 0.2° 0.0 ± 0.1° and 0.0 ± 0.2° for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.
Collapse
Affiliation(s)
| | - Mark Gardner
- The University of Sydney, Camperdown, NSW 2050, Australia
| | | | - Julia Johnson
- The University of Sydney, Camperdown, NSW 2050, Australia
| | - Paul Keall
- The University of Sydney, Camperdown, NSW 2050, Australia
| |
Collapse
|
3
|
Essers M, Mesch L, Beugeling M, Dekker J, de Kruijf W. Setup and intra-fractional motion measurements using surface scanning in head and neck cancer radiotherapy- A feasibility study. Phys Imaging Radiat Oncol 2024; 29:100563. [PMID: 38444887 PMCID: PMC10912619 DOI: 10.1016/j.phro.2024.100563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 12/30/2023] [Accepted: 02/15/2024] [Indexed: 03/07/2024] Open
Abstract
Background and purpose Surface-guided radiotherapy (SGRT) is applied to improve patient set-up and to monitor intra-fraction motion. Head and neck cancer (H&N) patients are usually fixated using 5-point thermoplastic masks, that are experienced as uncomfortable or even stressful. Therefore, the feasibility of irradiating H&N patients without a mask by using SGRT was examined. Material and methods Nineteen H&N patients were included in a simulation study. Once a week, before the standard treatment, a maskless treatment was simulated, using SGRT for setup and intrafraction motion monitoring. Initial patient setup accuracy and intrafraction motion was determined using ConeBeam CT (CBCT) images as well as SGRT before and after the (simulated) treatment. The clinical target volume to planning target volume (CTV-PTV) margin for intrafraction motion was calculated. Using patient questionnaires, the patient-friendliness H&N irradiation with and without mask was determined. Results Maskless setup with SGRT and CBCT was as accurate as with a mask. SGRT showed that intrafraction motion was gradual during the treatment. The CTV-PTV margin correcting for intrafraction motion was 1.7 mm for maskless treatment without interventions, and 1.2 mm if corrected for motions > 2 mm. For 19 % of fractions, the intrafraction motion, as detected by both SGRT and CBCT, was larger than 2 mm in at least one direction. Sixteen patients preferred maskless treatment, while 3 worried they would move too much. Conclusions Using SGRT and a standard head rest resulted in a patient-friendly treatment with accurate patient setup and acceptably small intrafraction motion for H&N patients.
Collapse
Affiliation(s)
- Marion Essers
- Institute Verbeeten, Medical Physics & Instrumentation, PO Box 90120, 5000 LA Tilburg, the Netherlands
| | - Lennart Mesch
- Institute Verbeeten, Radiotherapy, PO Box 90120, 5000 LA Tilburg, the Netherlands
| | - Maaike Beugeling
- Institute Verbeeten, Radiotherapy, PO Box 90120, 5000 LA Tilburg, the Netherlands
| | - Janita Dekker
- Institute Verbeeten, Medical Physics & Instrumentation, PO Box 90120, 5000 LA Tilburg, the Netherlands
| | - Willy de Kruijf
- Institute Verbeeten, Medical Physics & Instrumentation, PO Box 90120, 5000 LA Tilburg, the Netherlands
| |
Collapse
|
4
|
Park SY, Park JM, Kim JI, Choi CH, Chun M, Chang JH, Kim JH. Quantitative radiomics approach to assess acute radiation dermatitis in breast cancer patients. PLoS One 2023; 18:e0293071. [PMID: 37883380 PMCID: PMC10602246 DOI: 10.1371/journal.pone.0293071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 10/04/2023] [Indexed: 10/28/2023] Open
Abstract
PURPOSE We applied a radiomics approach to skin surface images to objectively assess acute radiation dermatitis in patients undergoing radiotherapy for breast cancer. METHODS A prospective cohort study of 20 patients was conducted. Skin surface images in normal, polarized, and ultraviolet (UV) modes were acquired using a skin analysis device before starting radiotherapy ('Before RT'), approximately 7 days after the first treatment ('RT D7'), on 'RT D14', and approximately 10 days after the radiotherapy ended ('After RT D10'). Eighteen types of radiomic feature ratios were calculated based on the values acquired 'Before RT'. We measured skin doses in ipsilateral breasts using optically stimulated luminescent dosimeters on the first day of radiotherapy. Clinical evaluation of acute radiation dermatitis was performed using the Radiation Therapy Oncology Group scoring criteria on 'RT D14' and 'After RT D10'. Several statistical analysis methods were used in this study to test the performance of radiomic features as indicators of radiodermatitis evaluation. RESULTS As the skin was damaged by radiation, the energy for normal mode and sum variance for polarized and UV modes decreased significantly for ipsilateral breasts, whereas contralateral breasts exhibited a smaller decrease with statistical significance. The radiomic feature ratios at 'RT D7' had strong correlations to skin doses and those at 'RT D14' and 'after RT D10' with statistical significance. CONCLUSIONS The energy for normal mode and sum variance for polarized and UV modes demonstrated the potential to evaluate and predict acute radiation, which assists in its appropriate management.
Collapse
Affiliation(s)
- So-Yeon Park
- Department of Radiation Oncology, Veterans Health Service Medical Center, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jong Min Park
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
- Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Jung-in Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Chang Heon Choi
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Minsoo Chun
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Ji Hyun Chang
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jin Ho Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| |
Collapse
|
5
|
Aoyama T, Shimizu H, Kitagawa T, Ishiguro Y, Kodaira T. Development of a device that remotely removes a mask in the head and neck immobilization system: a prototype and demonstration experiment. Radiol Phys Technol 2022; 15:249-254. [PMID: 35790662 DOI: 10.1007/s12194-022-00663-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 06/17/2022] [Accepted: 06/17/2022] [Indexed: 11/25/2022]
Abstract
In this study, a prototype device was developed to quickly remove the mask used to immobilize the head and neck by remotely releasing the quick fasteners. As a first step in investigating the usefulness of this prototype, we performed repeated removal tests and examined the accuracy of dose calculation. The results showed that the quick-release fasteners of a Type-S system (CIVCO Medical Solutions, Iowa, USA) could be removed remotely and accurately (success rate: 100%). Additionally, the dose errors in treatment planning were negligible (< 1.0%), and the gamma pass rate was equivalent (99.9%). Therefore, this prototype device with a remote system would help manage patient safety in emergencies, such as a disaster or a sudden change in the patient's condition. However, age-related deterioration with long-term clinical use or its ability to link with beam-off still requires further exploration.
Collapse
Affiliation(s)
- Takahiro Aoyama
- Department of Radiation Oncology, Aichi Cancer Centre, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, 464-8681, Japan.
- Graduate School of Medicine, Aichi Medical University, 1-1 Yazako-karimata, Nagakute, Aichi, 480-1195, Japan.
| | - Hidetoshi Shimizu
- Department of Radiation Oncology, Aichi Cancer Centre, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, 464-8681, Japan
| | - Tomoki Kitagawa
- Department of Radiation Oncology, Aichi Cancer Centre, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, 464-8681, Japan
| | - Yasunori Ishiguro
- Department of Radiation Oncology, Aichi Cancer Centre, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, 464-8681, Japan
| | - Takeshi Kodaira
- Department of Radiation Oncology, Aichi Cancer Centre, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, 464-8681, Japan
| |
Collapse
|
6
|
Comparing patient acceptability of MR-guided radiotherapy to conventional CBCT on two Elekta systems: a questionnaire-based survey. JOURNAL OF RADIOTHERAPY IN PRACTICE 2022. [DOI: 10.1017/s1460396922000206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Background and Purpose:
The magnetic resonance linear accelerator system (MR Linac) is a novel piece of radiotherapy (RT) equipment allowing the routine application of daily MR-guided treatment adaptation. The hardware design required for such technical capabilities and the increased complexity of the treatment workflow entails a notable departure from cone beam computed tomography (CBCT)-based RT. Patient tolerability of treatment is paramount to RT practice where high compliance is required. Presented is a comparative analysis of how such modality specific characteristics may ultimately impact the patient experience of treatment.
Materials and Methods:
Forty patients undergoing RT for prostate cancer (PCa) on either the MR Linac (n = 20) or a CBCT-based linac (n = 20) were provided with a validated patient reported outcomes measures (PROM’s) questionnaire at fraction 1 and fraction 20. The 18-item questionnaire provided patient responses recorded using a 4-point Likert scale, 0 denoting a response of ‘Not at all’, 1 ‘Slightly’, 2 ‘Moderately’ and 3 signifying ‘Very’. The analysis provided insight into both comparisons between modalities at singular time points (fractions 1 and 20), as well as a temporal analysis within a single modality, denoting changing patient experience.
Results:
Patients generally found the MR Linac treatment couch more comfortable, however, found the increase in treatment duration harder to tolerate. Responses for all items remained stable between first and last fraction across both cohorts, indicating minimal temporal variation within a single modality. None of the responses were statistically significant at the 0·01 level.
Conclusion:
Whether radiotherapy for PCa is delivered on a CBCT linac or the MR Linac, there is little difference in patient experience with minimal experiential variation within a single modality.
Collapse
|
7
|
Development of a new poly-ε-caprolactone with low melting point for creating a thermoset mask used in radiation therapy. Sci Rep 2021; 11:20409. [PMID: 34650081 PMCID: PMC8516973 DOI: 10.1038/s41598-021-00005-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 10/01/2021] [Indexed: 12/03/2022] Open
Abstract
This study aimed to develop a poly-ε-caprolactone (PCL) material that has a low melting point while maintaining the deformation ability. The new PCL (abbreviated as 4b45/2b20) was fabricated by mixing two types of PCL with different molecular weights, numbers of branches, and physical properties. To investigate the melting point, crystallization temperature, elastic modulus, and elongation at break for 4b45/2b20 and three commercially available masks, differential scanning calorimetry and tensile tests were performed. The melting point of 4b45/2b20 was 46.0 °C, and that of the commercially available masks was approximately 56.0 °C (55.7 °C–56.5 °C). The elastic modulus at 60 °C of 4b45/2b20 was significantly lower than the commercially available masks (1.1 ± 0.3 MPa and 46.3 ± 5.4 MPa, p = 0.0357). In addition, the elongation at break of 4b45/2b20 were significantly larger than the commercially available masks (275.2 ± 25.0% and 216.0 ± 15.2%, p = 0.0347). The crystallization temperature of 4b45/2b20 (22.1 °C) was clinically acceptable and no significant difference was found in the elastic modulus at 23 °C (253.7 ± 24.3 MPa and 282.0 ± 44.3 MPa, p = 0.4). As a shape memory-based thermoset material, 4b45/2b20 has a low melting point and large deformation ability. In addition, the crystallization temperature and strength are within the clinically acceptable standards. Because masks made using the new PCL material are formed with less pressure on the face than commercially available masks, it is a promising material for making a radiotherapy mask that can reduce the burden on patients.
Collapse
|
8
|
Cleland S, Chan P, Chua B, Crowe SB, Dawes J, Kenny L, Lin C, Obereigner E, Peet SC, Trapp JV, Poroa T, Kairn T. Dosimetric evaluation of a patient-specific 3D-printed oral positioning stent for head-and-neck radiotherapy. Phys Eng Sci Med 2021; 44:887-899. [PMID: 34110611 DOI: 10.1007/s13246-021-01025-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 06/03/2021] [Indexed: 12/21/2022]
Abstract
As head-and-neck radiotherapy treatments become more complex and sophisticated, and the need to control and stabilise the positioning of intra-oral anatomy becomes more important, leading the increasing use of oral positioning stents during head-and-neck radiotherapy simulation and delivery. As an alternative to the established practice of creating oral positioning stents using wax, this study investigated the use of a 3D printing technique. An Ender 5 3D printer (Creality 3D, Shenzhen, China) was used, with PLA+ "food-safe" polylactic acid filament (3D Fillies, Dandenong South, Australia), to produce a low-density 3D printed duplicate of a conventional wax stent. The physical and dosimetric effects of the two stents were evaluated using radiochromic film in a solid head phantom that was modified to include flexible parts. The Varian Eclipse treatment planning system (Varian Medical Systems, Palo Alto, USA) was used to calculate the dose from two different head-and-neck treatment plans for the phantom with each of the two stents. Examination of the resulting four dose distributions showed that both stents effectively pushed sensitive oral tissues away from the treatment targets, even though most of the phantom was solid. Film measurements confirmed the accuracy of the dose calculations from the treatment planning system, despite the steep density gradients in the treated volume, and demonstrated that the 3D print could be a suitable replacement for the wax stent. This study demonstrated a useful method for dosimetrically testing novel oral positioning stents. We recommend the development of flexible phantoms for future studies.
Collapse
Affiliation(s)
- Susannah Cleland
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,Queensland University of Technology, Brisbane, QLD, 4001, Australia.,Herston Bifabrication Institute, Metro North Hospital and Health Service, Herston, QLD, 4029, Australia.,Radiation Oncology Princess Alexandra Hospital Raymond Terrace, South Brisbane, QLD, 4101, Australia
| | - Philip Chan
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,University of Queensland, Brisbane, QLD, 4072, Australia
| | - Benjamin Chua
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,University of Queensland, Brisbane, QLD, 4072, Australia
| | - Scott B Crowe
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,Queensland University of Technology, Brisbane, QLD, 4001, Australia.,Herston Bifabrication Institute, Metro North Hospital and Health Service, Herston, QLD, 4029, Australia.,University of Queensland, Brisbane, QLD, 4072, Australia
| | - Jodi Dawes
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia
| | - Lizbeth Kenny
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,University of Queensland, Brisbane, QLD, 4072, Australia
| | - Charles Lin
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,University of Queensland, Brisbane, QLD, 4072, Australia
| | - Elise Obereigner
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,Herston Bifabrication Institute, Metro North Hospital and Health Service, Herston, QLD, 4029, Australia
| | - Samuel C Peet
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,Queensland University of Technology, Brisbane, QLD, 4001, Australia
| | - Jamie V Trapp
- Queensland University of Technology, Brisbane, QLD, 4001, Australia
| | - Tania Poroa
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia.,Herston Bifabrication Institute, Metro North Hospital and Health Service, Herston, QLD, 4029, Australia
| | - Tanya Kairn
- Royal Brisbane and Women's Hospital, Herston, QLD, 4029, Australia. .,Queensland University of Technology, Brisbane, QLD, 4001, Australia. .,Herston Bifabrication Institute, Metro North Hospital and Health Service, Herston, QLD, 4029, Australia. .,University of Queensland, Brisbane, QLD, 4072, Australia.
| |
Collapse
|
9
|
Individual 3D-printed fixation masks for radiotherapy: first clinical experiences. Int J Comput Assist Radiol Surg 2021; 16:1043-1049. [PMID: 34021859 PMCID: PMC8166668 DOI: 10.1007/s11548-021-02393-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 04/27/2021] [Indexed: 11/13/2022]
Abstract
Purpose To show the feasibility of 3D-printed fixation masks for whole brain radiation therapy in a clinical setting and perform a first comparison to an established thermoplastic mask system. Methods Six patients were irradiated with whole brain radiotherapy using individually 3D-printed masks. Daily image guidance and position correction were performed prior to each irradiation fraction. The vectors of the daily position correction were compared to two collectives of patients, who were irradiated using the standard thermoplastic mask system (one cohort with head masks; one cohort with head and neck masks). Results The mean systematic errors in the experimental cohort ranged between 0.59 and 2.10 mm which is in a comparable range to the control groups (0.18 mm–0.68 mm and 0.34 mm–2.96 mm, respectively). The 3D-printed masks seem to be an alternative to the established thermoplastic mask systems. Nevertheless, further investigation will need to be performed. Conclusion The prevailing study showed a reliable and reproducible interfractional positioning accuracy using individually 3D-printed masks for whole brain irradiation in a clinical routine. Further investigations, especially concerning smaller target volumes or other areas of the body, need to be performed before using the system on a larger basis.
Collapse
|
10
|
Grilo AM, Santos B, Baptista I, Monsanto F. Exploring the cancer patients' experiences during external radiotherapy: A systematic review and thematic synthesis of qualitative and quantitative evidence. Eur J Oncol Nurs 2021; 52:101965. [PMID: 34023669 DOI: 10.1016/j.ejon.2021.101965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 03/28/2021] [Accepted: 04/14/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the subjective experience of adult cancer patients undergoing external radiotherapy and provide evidence for better practices in radiotherapy services. METHODS A systematic review was performed according to the PRISMA Statement Guidelines. Qualitative and mixed studies were identified through five electronic databases (CINAHL, PsychINFO, Medline, Scopus and Web of Science), between March and April 2020, using defined criteria. Methodological quality assessment was conducted, and the data integrated into a thematic synthesis. RESULTS Of the 886 studies identified, 13 met our inclusion criteria. Patients experiences were described into four main themes: (1) Time, (2) Physical Environment, (3) Treatment Concerns and (4) Radiotherapy Team. Time refers to waiting time and treatment time; Physical Environment states temperature in the treatment room and equipment; Treatment Concerns included side effects, daily activities, positioning and immobilization and treatment preparation (e.g., bladder filling); radiotherapy team comprised patients support; response to patients needs and recognized team. The generating analytical phase of thematic analysis allowed us to recognize that the effectiveness of the radiotherapy team operates as a facilitator of the patients' experience. In contrast, time in the waiting room, the treatment preparation when is required, and the positioning and immobilization, specifically for the neck and head patients, act as barriers. CONCLUSION Four distinct themes were identified to be positively and negatively associated with patients' experience during external radiotherapy. The evidence provides valuable recommendations to improved radiotherapy services organization, as well as to the delivery of more patient-centred care adjusted to the concerns and needs of patients.
Collapse
Affiliation(s)
- Ana Monteiro Grilo
- H&TRC-Health & Technology Research Center, ESTeSL- Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, Portugal; CICPsi - Research Center for Psychological Science, Faculty of Psychology, University of Lisbon, Portugal.
| | - Bárbara Santos
- Medical Imaging and RT Degree, Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, Portugal.
| | - Inês Baptista
- Medical Imaging and RT Degree, Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, Portugal.
| | - Fátima Monsanto
- H&TRC-Health & Technology Research Center, ESTeSL- Escola Superior de Tecnologia da Saúde, Instituto Politécnico de Lisboa, Portugal.
| |
Collapse
|
11
|
Asfia A, Deepak B, Novak JI, Rolfe B, Kron T. Infill selection for 3D printed radiotherapy immobilisation devices. Biomed Phys Eng Express 2020; 6. [DOI: 10.1088/2057-1976/abb981] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 09/17/2020] [Indexed: 12/19/2022]
|
12
|
Fukao M, Okamura K, Sabu S, Akino Y, Arimura T, Inoue S, Kado R, Seo Y. Repositioning accuracy of a novel thermoplastic mask for head and neck cancer radiotherapy. Phys Med 2020; 74:92-99. [PMID: 32450542 DOI: 10.1016/j.ejmp.2020.05.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 03/05/2020] [Accepted: 05/08/2020] [Indexed: 10/24/2022] Open
Abstract
PURPOSE The aim of this study was to assess the reproducibility of patient shoulder position immobilized with a novel and innovative prototype mask (E-Frame, Engineering System). METHODS The E-frame mask fixes both shoulders and bisaxillary regions compared with that of a commercial mask (Type-S, CIVCO). Thirteen and twelve patients were immobilized with the Type-S and E-Frame mask systems, respectively. For each treatment fraction, cone-beam CT (CBCT) images of the patient were acquired and retrospectively analyzed. The CBCT images were registered to the planning CT based on the cervical spine, and then the displacements of the acromial extremity of the clavicle were measured. RESULTS The systematic and random errors between the two mask systems were evaluated. The differences of the systematic errors between the two mask systems were not statistically significant. The mean random errors in the three directions (AP, SI and LR) were 2.7 mm, 3.1 mm and 1.5 mm, respectively for the Type-S mask, and 2.8 mm 2.5 mm and 1.4 mm, respectively for the E-Frame mask. The random error of the E-Frame masks in the SI direction was significantly smaller than that of the Type-S. The number of cases showing displacements exceeding 10 mm in the SI direction for at least one fraction was eight (61% of 13 cases) and three (25% of 12 cases) for Type-S and E-Frame masks, respectively. CONCLUSIONS The E-Frame masks reduced the random displacements of patient's shoulders in the SI direction, effectively preventing large shoulder shifts that occurred frequently with Type-S masks.
Collapse
Affiliation(s)
- Mari Fukao
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Keita Okamura
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Shotaro Sabu
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Yuichi Akino
- Oncology Center, Osaka University Hospital, 2-2 (D10), Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takehiro Arimura
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Shinichi Inoue
- Department of Medical Technology, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Ryoko Kado
- Department of Nursing, Osaka University Hospital, 2-15, Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Yuji Seo
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10), Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
13
|
A comparative study between open-face and closed-face masks for head and neck cancer (HNC) in radiation therapy. Rep Pract Oncol Radiother 2020; 25:382-388. [PMID: 32322177 DOI: 10.1016/j.rpor.2020.03.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/09/2019] [Accepted: 03/12/2020] [Indexed: 11/20/2022] Open
Abstract
Aim To determine the setup reproducibility in the radiation treatment of Head and Neck (HN) patients using open face head and shoulder masks (OHSM) with customized headrest (CHR) versus standard closed head and shoulder masks (CHSM) and to determine the patient's level of comfort and satisfaction for both masks. Methods Forty patients were prospectively randomized into two groups using simple random sampling. Group 1 was assigned with CHSMs, immobilized with a standard HR (SHR) while Group 2 was assigned with OHSMs, and immobilized with CHR. Cone beam computed tomography (CBCT) was taken the first 3 days, followed by weekly CBCT (prior treatment) with results registered to the planning CT to determine translational and rotational inter-fraction shifts and to verify accuracy. Mean (M) and standard deviation (SD) of the systematic and random setup errors of the 2 arms in the translational and rotational directions were analyzed, using Independent t-test and Mann-Whitney U test. Patient comfort was measured using a Likert questionnaire. Results The vertical, lateral, longitudinal and Z/roll rotational shifts were not significantly different between the two masks. X/yaw and Y/pitch rotational shifts were significantly greater in Group 2 versus Group 1, for both systematic (p = 0.009 and 0.046, respectively) and random settings (p = 0.016 and 0.020) but still within three degrees. Patients reported higher neck and shoulder comfort (p = 0.020) and overall satisfaction (p = 0.026) using the OHSM with the CHR versus the CHSM with the SHR during CT simulation. Conclusion Open masks provide comparable yet comfortable immobilization to closed masks for HN radiotherapy.
Collapse
|
14
|
Olausson K, Sharp L, Fransson P, Nyholm T, Zackrisson B, Östlund U. What matters to you? - Free-text comments in a questionnaire from patients undergoing radiotherapy. Tech Innov Patient Support Radiat Oncol 2020; 13:11-16. [PMID: 32128457 PMCID: PMC7042152 DOI: 10.1016/j.tipsro.2019.11.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 10/13/2019] [Accepted: 11/22/2019] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Most cancer patients undergo external radiotherapy (RT) at some stage during their treatment trajectory and RT is often associated with unfamiliar procedures in a highly technical environment. The purpose of this study was to explore how patients experience RT and the related processes, as described in free-text comments in a large Swedish survey with questionnaires including items on psychosocial climate and treatment environment. METHODS The data consisted of free-text comments from one open-ended question: "Is there anything else you want us to know" and were analysed using qualitative content analysis. RESULTS Of 825 returned questionnaires, 261 contained free-text comments from patients (32%). The hand-written, free-text comments reflected the patients' experience of the RT process and were abstracted into the four major categories with sub-categories: experiencing the high-tech RT environment, understanding the RT procedures and side effects, dealing with daily life during RT, and the nurses' role and performance. The categories reflect the patients' experiences and emphasize how important it is to evaluate what really matters to the patients when changing procedures, practices, and how to minimize disturbances in the patients' daily lives. CONCLUSION The main conclusions from this study are that the involvement of patients in choosing daily appointment times, providing good information during the RT process to make the patients feel safe, experience and attitude of the staff and respect for the patient's autonomy are highly ranked values for patients. An implementation of person-centred care may help relieve many of these problems.
Collapse
Affiliation(s)
| | - Lena Sharp
- Karolinska Institute, Department of Learning, Informatics, Management and Ethics, Stockholm, Sweden
- Regional Cancer Centre, Stockholm-Gotland, Sweden
| | - Per Fransson
- Umeå University, Department of Nursing, Umeå, Sweden
| | - Tufve Nyholm
- Umeå University, Department of Radiation Sciences, Umeå, Sweden
| | | | - Ulrika Östlund
- Centre for Research & Development, Uppsala University/Region Gävleborg, Sweden
- Faculty of Medicine and Health, School of Health Sciences, Örebro University, Örebro, Sweden
- Department of Public Health and Caring Sciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|
15
|
Keast R, Sundaresan P, Burns M, Butow PN, Dhillon HM. Exploring head and neck cancer patients' experiences with radiation therapy immobilisation masks: A qualitative study. Eur J Cancer Care (Engl) 2019; 29:e13215. [PMID: 31883285 DOI: 10.1111/ecc.13215] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 10/08/2019] [Accepted: 12/11/2019] [Indexed: 12/01/2022]
Abstract
OBJECTIVE Head and neck cancer (HNC) patients commonly undergo radiation therapy requiring immobilisation by a mask. Some find the mask distressing, and this can disrupt treatment sessions. This study aimed to explore the patient experience of immobilisation masks in the Australian and New Zealand (ANZ) context, to guide possible intervention. METHODS Semi-structured interviews were conducted with HNC patients who had completed radiation therapy, recruited via hospitals and social media. Interviews continued until data saturation; then, three further interviews were conducted for member-checking purposes. Qualitative methodology with thematic analysis was used to identify themes in the data. RESULTS Twenty HNC survivors participated in interviews, and seven themes were identified: information received by participants, potential predictors of mask anxiety, participant reactions to the mask, trajectories of mask anxiety, supportive behaviour and communication of health professionals, coping with the mask, and thoughts and feelings about the mask. CONCLUSIONS Participant experiences of the immobilisation mask were diverse. The findings fit with Lazarus and Folkman's (Stress, appraisal, and coping. New York, NY: Springer Pub. Co) transactional model of stress and coping, as participants appeared to make cognitive appraisals of the mask and their coping abilities throughout treatment, resulting in varied levels of mask-related distress. Complex intervention is recommended to reduce mask anxiety in HNC patients across ANZ.
Collapse
Affiliation(s)
- Rachael Keast
- Faculty of Science, School of Psychology, Centre for Medical Psychology & Evidence-Based Decision-making, University of Sydney, Sydney, NSW, Australia
| | - Puma Sundaresan
- Radiation Oncology Network, Western Sydney Local Health District, Sydney, NSW, Australia.,Sydney Medical School, University of Sydney, Sydney, NSW, Australia
| | - Melissa Burns
- Radiation Oncology Network, Western Sydney Local Health District, Sydney, NSW, Australia
| | - Phyllis N Butow
- Faculty of Science, School of Psychology, Centre for Medical Psychology & Evidence-Based Decision-making, University of Sydney, Sydney, NSW, Australia.,Psycho-Oncology Cooperative Research Group, University of Sydney, Sydney, NSW, Australia
| | - Haryana M Dhillon
- Faculty of Science, School of Psychology, Centre for Medical Psychology & Evidence-Based Decision-making, University of Sydney, Sydney, NSW, Australia.,Psycho-Oncology Cooperative Research Group, University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
16
|
Prehabilitation for patient positioning: pelvic exercises assist in minimizing inter-fraction sacral slope variability during radiation therapy. Med Oncol 2019; 37:3. [PMID: 31713056 DOI: 10.1007/s12032-019-1322-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 10/14/2019] [Indexed: 10/25/2022]
Abstract
Reproducible patient positioning is essential for precision in radiation therapy (RT) delivery. We tested the hypothesis that a structured daily pre-treatment stretching regimen is both feasible and effective for minimizing variability in positioning, as measured by sacral slope angles (SSA). Eight female subjects undergoing pelvic radiotherapy performed a structured daily hip exercise regimen (extension and external rotation) immediately prior to both simulation imaging and daily treatment, throughout their RT course. This exercising cohort was compared to a retrospective review of 20 subjects (17 women and 3 men) undergoing RT, who had usual care. SSA measurements from daily pre-treatment imaging were compared to SSA measurements from the simulation CT. The average variation in SSA among the intervention subjects was 0.91° (± 0.58°), with a range among subjects of 0.57°-1.27°. The average variation for the control subjects was 2.27° (± 1.43°), ranging 1.22°-5.09°. The difference between the two groups was statistically significant (p = 0.0001). There was a statistically significant SSA variation between groups at each week of treatment. There was no significant variation among the intervention subjects between week 1 and later weeks, whereas subjects in the control group demonstrated significant SSA variation between week 1 and later weeks. We demonstrated a significant decrease in the variability of SSA by implementing a simple pre-treatment exercise program, while control subjects exhibited increasing variation in SSA over the course of treatment. We conclude that there is a potential benefit of prehabilitation during pelvic RT; however, a larger randomized control trial is required to confirm the findings.Clinical Trial: This research project was approved by the University of Massachusetts Medical School IRB (IRB ID H00012353) on January 21, 2017. The study is listed on ClinicalTrials.gov, provided by the U.S. National Library of Medicine, found with identifier NCT03242538.
Collapse
|
17
|
Nixon JL, Brown B, Pigott AE, Turner J, Brown E, Bernard A, Wall LR, Ward EC, Porceddu SV. A prospective examination of mask anxiety during radiotherapy for head and neck cancer and patient perceptions of management strategies. J Med Radiat Sci 2019; 66:184-190. [PMID: 31343118 PMCID: PMC6745384 DOI: 10.1002/jmrs.346] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2019] [Revised: 06/24/2019] [Accepted: 06/26/2019] [Indexed: 11/25/2022] Open
Abstract
INTRODUCTION Distress related to wearing an immobilisation mask for radiotherapy treatment (RT) is a common experience for the person undergoing RT for head and neck cancer (HNC). Described as 'mask anxiety', there is little known about the patterns of this distress through the course of the treatment or what strategies are being used by people to help alleviate mask anxiety. METHODS The study used a prospective cohort design to examine the patterns of patient-reported mask anxiety during the course of RT, using a modified Distress Thermometer (DT) and a survey to explore strategies patients used to assist their mask anxiety. RESULTS Thirty-five participants, who identified as experiencing mask anxiety, were followed throughout RT treatment. At baseline, females were more likely to experience higher mask anxiety (P = 0.03). Across the course of treatment, mask anxiety significantly (P < 0.001) reduced within the total cohort. In 72% of participants, the level of initial distress was found to reduce over time. Only 22% experienced mask anxiety that remained constant. Few (6%) experienced an increase in mask anxiety across the course of RT. Participants reported relying on intervention from health professionals, self-taught strategies, music, visualisation and medication to manage their mask anxiety. CONCLUSIONS Due to its high prevalence and variable patterns over time, it is recommended that routine screening for mask anxiety be implemented as standard care throughout the course of RT for HNC. Multiple, diverse strategies are being used by patients and studies are needed to develop effective interventions for managing mask anxiety.
Collapse
Affiliation(s)
- Jodie L. Nixon
- Occupational Therapy DepartmentPrincess Alexandra HospitalBrisbaneAustralia
- School of Health and Rehabilitation SciencesThe University of QueenslandBrisbaneAustralia
| | - Bena Brown
- School of Health and Rehabilitation SciencesThe University of QueenslandBrisbaneAustralia
- Speech Pathology DepartmentPrincess Alexandra HospitalBrisbaneAustralia
- Centre for Functioning and Health ResearchMetro South Hospital and Health ServiceWoolloongabbaAustralia
| | - Amanda E. Pigott
- Occupational Therapy DepartmentPrincess Alexandra HospitalBrisbaneAustralia
- School of Health and Rehabilitation SciencesThe University of QueenslandBrisbaneAustralia
| | - Jane Turner
- Faculty of MedicineThe University of QueenslandBrisbaneAustralia
| | - Elizabeth Brown
- Radiation Oncology DepartmentPrincess Alexandra HospitalBrisbaneAustralia
| | - Anne Bernard
- QFAB Bioinformatics, Institute for Molecular Bioscience, The University of QueenslandBrisbaneAustralia
| | - Laurelie R. Wall
- School of Health and Rehabilitation SciencesThe University of QueenslandBrisbaneAustralia
- Centre for Functioning and Health ResearchMetro South Hospital and Health ServiceWoolloongabbaAustralia
| | - Elizabeth C. Ward
- School of Health and Rehabilitation SciencesThe University of QueenslandBrisbaneAustralia
- Centre for Functioning and Health ResearchMetro South Hospital and Health ServiceWoolloongabbaAustralia
| | - Sandro V. Porceddu
- Faculty of MedicineThe University of QueenslandBrisbaneAustralia
- Radiation Oncology DepartmentPrincess Alexandra HospitalBrisbaneAustralia
| |
Collapse
|
18
|
Vulpe H, Save AV, Xu Y, Elliston CD, Garrett MD, Wu CC, Cheng SK, Jani AH, Bruce JN, McKhann GM, Wang TJC, Sisti MB. Frameless Stereotactic Radiosurgery on the Gamma Knife Icon: Early Experience From 100 Patients. Neurosurgery 2019; 86:509-516. [DOI: 10.1093/neuros/nyz227] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Accepted: 02/25/2019] [Indexed: 12/25/2022] Open
Abstract
Abstract
BACKGROUND
The Gamma Knife (GK) Icon (Elekta AB) uses a cone-beam computed tomography (CBCT) scanner and an infrared camera system to support the delivery of frameless stereotactic radiosurgery (SRS). There are limited data on patients treated with frameless GK radiosurgery (GKRS).
OBJECTIVE
To describe the early experience, process, technical details, and short-term outcomes with frameless GKRS at our institution.
METHODS
We reviewed our patient selection and described the workflow in detail, including image acquisition, treatment planning, mask-based immobilization, stereotactic CBCT localization, registration, treatment, and intrafraction monitoring. Because of the short interval of follow-up, we provide crude rates of local control.
RESULTS
Data from 100 patients are reported. Median age is 67 yr old. 56 patients were treated definitively, 21 postoperatively, and 23 had salvage GKRS for recurrence after surgery. Forty-two patients had brain metastases, 26 meningiomas, 16 vestibular schwannomas, 9 high-grade gliomas, and 7 other histologies. Median doses to metastases were 20 Gy in 1 fraction (range: 14-21), 24 Gy in 3 fractions (range: 19.5-27), and 25 Gy in 5 fractions (range: 25-30 Gy). Thirteen patients underwent repeat SRS to the same area. Median treatment time was 17.7 min (range: 5.8-61.7). We found an improvement in our workflow and a greater number of patients eligible for GKRS because of the ability to fractionate treatments.
CONCLUSION
We report a large cohort of consecutive patients treated with frameless GKRS. We look forward to studies with longer follow-up to provide valuable data on clinical outcomes and to further our understanding of the radiobiology of hypofractionation in the brain.
Collapse
Affiliation(s)
- Horia Vulpe
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
| | - Akshay V Save
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Department of Neurological Surgery, Columbia University Irving Medical Center, New York, New York
| | - Yuanguang Xu
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
| | - Carl D Elliston
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
| | - Matthew D Garrett
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
| | - Cheng-Chia Wu
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
| | - Simon K Cheng
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
- Department of Otolaryngology/Head and Neck Surgery, Columbia University Irving Medical Center, New York, New York
| | - Ashish H Jani
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
| | - Jeffrey N Bruce
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
- Department of Neurological Surgery, Columbia University Irving Medical Center, New York, New York
| | - Guy M McKhann
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
- Department of Neurological Surgery, Columbia University Irving Medical Center, New York, New York
| | - Tony J C Wang
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
- Department of Neurological Surgery, Columbia University Irving Medical Center, New York, New York
| | - Michael B Sisti
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, New York
- Herbert Irving Comprehensive Cancer Center, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York
- Department of Neurological Surgery, Columbia University Irving Medical Center, New York, New York
- Department of Otolaryngology/Head and Neck Surgery, Columbia University Irving Medical Center, New York, New York
| |
Collapse
|
19
|
Divneet M, Quoc-Anh H, Betsy W, Gia J, Denise R, Christopher W, Yi SK. Comparison of two thermoplastic immobilization mask systems in daily volumetric image guided radiation therapy for head and neck cancers. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aad574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
20
|
Hoisak JD, Pawlicki T. The Role of Optical Surface Imaging Systems in Radiation Therapy. Semin Radiat Oncol 2018; 28:185-193. [DOI: 10.1016/j.semradonc.2018.02.003] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
21
|
Massager N, Renier C, Devriendt D. Acute skin allergy to thermoplastic mask used for patient immobilization during radiation therapy: a case report. J Med Case Rep 2018; 12:181. [PMID: 29945670 PMCID: PMC6020304 DOI: 10.1186/s13256-018-1715-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 05/14/2018] [Indexed: 11/17/2022] Open
Abstract
Background Radiosurgical treatments of brain tumors, vascular malformations, and functional disorders are more and more frequently used. Gamma Knife irradiation with the Icon system necessitates the use of a thermoplastic mask for head immobilization during treatment. Acute cutaneous allergy to thermoplastic masks has never been reported. Case presentation A 71-year-old Caucasian woman treated radiosurgically for a sphenoidal meningioma using the Icon Gamma Knife system developed an acute allergic skin reaction to the thermoplastic mask used for head immobilization. Corticoids and antihistamine drugs were needed to continue the radiosurgical procedure to its end. Conclusion Allergic reaction of the skin during radiosurgery with a thermoplastic mask for head fixation can develop due to cutaneous contact of the face with the mask.
Collapse
Affiliation(s)
- Nicolas Massager
- Department of Neurosurgery, University Hospital Tivoli, avenue Max Buset 34, 7100, La Louviere, Belgium.
| | - Cécile Renier
- Department of Neurosurgery, University Hospital Tivoli, avenue Max Buset 34, 7100, La Louviere, Belgium.,Department of Radiophysics, Institut Bordet, boulevard de Waterloo 212, 1000, Brussels, Belgium
| | - Daniel Devriendt
- Department of Neurosurgery, University Hospital Tivoli, avenue Max Buset 34, 7100, La Louviere, Belgium.,Department of Radiation Therapy, Institut Bordet, boulevard de Waterloo 212, 1000, Brussels, Belgium
| |
Collapse
|
22
|
Lu Y, Ni X, Yu J, Ni X, Sun Z, Wang J, Sun S, Wang J. Lower limb immobilization device induced small setup errors in the radiotherapy. Medicine (Baltimore) 2018; 97:e0384. [PMID: 29642197 PMCID: PMC5908616 DOI: 10.1097/md.0000000000010384] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The aim of this study was to design a lower limb immobilization device and investigate its clinical application in the radiotherapy of the lower limbs.Around 38 patients who underwent lower limb radiotherapy using the designed immobilization device were included in this study. The setup errors were calculated by comparison of the portal images and the simulator films or digital reconstructed radiographs (DRRs).From all 38 patients accomplished the radiotherapy using this device, 178 anteroposterior portal images and 178 lateral portal images were used for the analysis of the positional accuracy. Significant differences were observed in the setup error of the head-foot direction compared with the left-right direction (t = 3.404, P = .002) and the anterior-posterior directions (t = 3.188, P = .003). No statistical differences were identified in the setup error in the left-right direction and anterior-posterior direction (t = 0.497, P = .622).The use of the in-house designed lower limb immobilization device allowed for relatively small setup errors. Furthermore, it showed satisfactory accuracy and repeatability.
Collapse
|
23
|
Haefner MF, Giesel FL, Mattke M, Rath D, Wade M, Kuypers J, Preuss A, Kauczor HU, Schenk JP, Debus J, Sterzing F, Unterhinninghofen R. 3D-Printed masks as a new approach for immobilization in radiotherapy - a study of positioning accuracy. Oncotarget 2018; 9:6490-6498. [PMID: 29464087 PMCID: PMC5814227 DOI: 10.18632/oncotarget.24032] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2017] [Accepted: 01/02/2018] [Indexed: 11/25/2022] Open
Abstract
We developed a new approach to produce individual immobilization devices for the head based on MRI data and 3D printing technologies. The purpose of this study was to determine positioning accuracy with healthy volunteers. 3D MRI data of the head were acquired for 8 volunteers. In-house developed software processed the image data to generate a surface mesh model of the immobilization mask. After adding an interface for the couch, the fixation setup was materialized using a 3D printer with acrylonitrile butadiene styrene (ABS). Repeated MRI datasets (n=10) were acquired for all volunteers wearing their masks thus simulating a setup for multiple fractions. Using automatic image-to-image registration, displacements of the head were calculated relative to the first dataset (6 degrees of freedom). The production process has been described in detail. The absolute lateral (x), vertical (y) and longitudinal (z) translations ranged between −0.7 and 0.5 mm, −1.8 and 1.4 mm, and −1.6 and 2.4 mm, respectively. The absolute rotations for pitch (x), yaw (y) and roll (z) ranged between −0.9 and 0.8°, −0.5 and 1.1°, and −0.6 and 0.8°, respectively. The mean 3D displacement was 0.9 mm with a standard deviation (SD) of the systematic and random error of 0.2 mm and 0.5 mm, respectively. In conclusion, an almost entirely automated production process of 3D printed immobilization masks for the head derived from MRI data was established. A high level of setup accuracy was demonstrated in a volunteer cohort. Future research will have to focus on workflow optimization and clinical evaluation.
Collapse
Affiliation(s)
- Matthias Felix Haefner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Frederik Lars Giesel
- Department of Nuclear Medicine, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Matthias Mattke
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Daniel Rath
- Department of Nuclear Medicine, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Moritz Wade
- Department of Nuclear Medicine, Heidelberg University Hospital, 69120 Heidelberg, Germany.,Institute of Antropomatics and Robotics, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany
| | - Jacob Kuypers
- Department of Nuclear Medicine, Heidelberg University Hospital, 69120 Heidelberg, Germany.,Institute of Antropomatics and Robotics, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany
| | - Alan Preuss
- Department of Nuclear Medicine, Heidelberg University Hospital, 69120 Heidelberg, Germany.,Institute of Antropomatics and Robotics, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany
| | - Hans-Ulrich Kauczor
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Jens-Peter Schenk
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Juergen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Florian Sterzing
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany.,Department of Radiation Oncology Kempten, 87439 Kempten, Germany
| | - Roland Unterhinninghofen
- Institute of Antropomatics and Robotics, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany.,Institute of Robotics and Mechatronics, German Aerospace Center, 82234 Oberpfaffenhofen-Weßling, Germany
| |
Collapse
|
24
|
Olausson K, Holst Hansson A, Zackrisson B, Edvardsson D, Östlund U, Nyholm T. Development and psychometric testing of an instrument to measure the patient's experience of external radiotherapy: The Radiotherapy Experience Questionnaire (RTEQ). Tech Innov Patient Support Radiat Oncol 2017; 3-4:7-12. [PMID: 32095560 PMCID: PMC7033812 DOI: 10.1016/j.tipsro.2017.06.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 02/14/2017] [Accepted: 06/29/2017] [Indexed: 12/03/2022] Open
Abstract
A new instrument to measure the patient’s comfort and experiences during RT. The instrument gains the patients’ perspectives of the RT procedures. RTEQ has a possible application for evaluation of newly introduced techniques.
Background The patient’s perception of external radiotherapy (RT) procedures and equipment is important to evaluate as a complement to endpoints such as treatment outcome and reproducibility. There is a lack of a proper, psychometrically robust instrument to evaluate the patient’s comfort and experience of the external RT procedure. Hence, this study aimed to develop and test an instrument to measure the patient’s experience during external RT. Material and Methods A preliminary 34-item questionnaire was generated from research literature, expert consultations and patient interviews, and it was distributed to patients (n = 825) at 8 RT units in Sweden. The answers were subjected to item analysis and reduction by using exploratory factor analysis. The reliability of the final questionnaire was evaluated using Cronbach’s alpha. Mean scale scores were compared across gender, length of RT and treatment area. Results Most items were highly skewed towards positive responses. Scree plot analyses of the 34-item correlation matrix identified six underlying themes explaining 68% of the total variance. After item reduction, the 6 themes explained 73% of the variance in a 23-item questionnaire. Cronbach’s alpha was satisfactory for all themes (between 0.79 and 0.9). Significant differences between treatment areas were found for two scales: situational unease and situational repose. Conclusion The RT Experience Questionnaire is a tentatively valid and reliable instrument to measure how patients experience the external RT session process and the environment in the treatment room.
Collapse
Affiliation(s)
- Kristina Olausson
- Umeå University, Department of Radiation Sciences, Umeå, Sweden
- Corresponding author at: Department of Radiation Sciences, Umeå University Hospital, SE 901 87 Umeå, Sweden.
| | - Annette Holst Hansson
- Department of Care Sciences, Faculty of Health and Society, Malmö, Sweden
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | | | - David Edvardsson
- La Trobe University/Austin Health Clinical School of Nursing, Melbourne, Australia
- Umeå University, Department of Nursing, Umeå, Sweden
| | - Ulrika Östlund
- Centre for Research & Development, Uppsala University/Region Gävleborg, Sweden
- Centre for Collaborative Palliative Care, Linnaeus University, Kalmar, Sweden
| | - Tufve Nyholm
- Umeå University, Department of Radiation Sciences, Umeå, Sweden
- Department of Immunology, Genetics and Pathology, Medical Radiation Science, Uppsala University, Uppsala, Sweden
| |
Collapse
|
25
|
Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient's pain and anxiety. Radiat Oncol 2017; 12:72. [PMID: 28449698 PMCID: PMC5408424 DOI: 10.1186/s13014-017-0807-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 04/13/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In patients with head-neck cancer treated with IMRT, immobility of the upper part of the body during radiation is maintained by means of customised immobilisation devices. The main purpose of this study was to determine how the procedures for preparation of customised immobilisation systems and the patients characteristics influence the extent of setup errors. METHODS A longitudinal, prospective study involving 29 patients treated with IMRT. Data were collected before CT simulation and during all the treatment sessions (528 setup errors analysed overall); the correlation with possible risk factors for setup errors was explored using a linear mixed model. RESULTS Setup errors were not influenced by the patient's anxiety and pain. Temporary removal of the thermoplastic mask before carrying out the CT simulation shows statistically borderline, clinically relevant, increase of setup errors (+24.7%, 95% CI: -0.5% - 55.8%). Moreover, a unit increase of radiation therapists who model the customised thermoplastic mask is associated to a -18% (-29.2% - -4.9%) reduction of the errors. The setup error is influenced by the patient's physical features; in particular, it increases both in patients in whom the treatment position is obtained with 'Shoulder down' (+27.9%, 2.2% - 59.7%) and in patients with 'Scoliosis/kyphosis' problems (+65.4%, 2.3% - 164.2%). Using a 'Small size standard plus customized neck support device' is associated to a -52.3% (-73.7% - -11.2%) reduction. The increase in number of radiation therapists encountered during the entire treatment cycle does not show associations. Increase in the body mass index is associated with a slight reduction in setup error by (-2.8%, -5% - -0.7%). CONCLUSION The position of the patient obtained by forcing the shoulders downwards, clinically significant scoliosis or kyphosis and the reduction of the number of radiation therapists who model the thermoplastic mask are found to be statistically significant risk factors that can cause an increase in setup errors, while the use of 'Small size' neck support device and patient BMI can diminish them.
Collapse
|
26
|
Sato K, Takeda K, Dobashi S, Kadoya N, Ito K, Chiba M, Kishi K, Yanagawa I, Jingu K. Evaluation of the Positional Accuracy and Dosimetric Properties of a Three-dimensional Printed Device for Head and Neck Immobilization. Nihon Hoshasen Gijutsu Gakkai Zasshi 2017; 73:57-65. [PMID: 28111399 DOI: 10.6009/jjrt.2017_jsrt_73.1.57] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Our aim was to investigate the feasibility of a three-dimensional (3D) -printed head-and-neck (HN) immobilization device by comparing its positional accuracy and dosimetric properties with those of a conventional immobilization device (CID). We prepared a 3D-printed immobilization device (3DID) consisting of a mask and headrest with acrylonitrile-butadiene-styrene resin developed from the computed tomography data obtained by imaging a HN phantom. For comparison, a CID comprising a thermoplastic mask and headrest was prepared using the same HN phantom. We measured the setup error using the ExacTrac X-ray image system. Furthermore, using the ionization chamber and the water-equivalent phantom, we measured the changes in the dose due to the difference in the immobilization device material from the photon of 4 MV and 6 MV. The positional accuracy of the two devices were almost similar in each direction except in the vertical, lateral, and pitch directions (t-test, p<0.0001), and the maximum difference was 1 mm, and 1°. The standard deviations were not statistically different in each direction except in the longitudinal (F-test, p=0.034) and roll directions (F-test, p<0.0001). When the thickness was the same, the dose difference was almost similar at a 50 mm depth. At a 1 mm depth, the 3DID-plate had a 2.9-4.2% lower dose than the CID-plate. This study suggested that the positional accuracy and dosimetric properties of 3DID were almost similar to those of CID.
Collapse
|
27
|
Thondykandy BA, Swamidas JV, Agarwal J, Gupta T, Laskar SG, Mahantshetty U, Iyer SS, Mukherjee IU, Shrivastava SK, Deshpande DD. Setup error analysis in helical tomotherapy based image-guided radiation therapy treatments. J Med Phys 2016; 40:233-9. [PMID: 26865760 PMCID: PMC4728895 DOI: 10.4103/0971-6203.170796] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
The adequacy of setup margins for various sites in patients treated with helical tomotherapy was investigated. A total of 102 patients were investigated. The breakdown of the patients were as follows: Twenty-five patients each in brain, head and neck (H and N), and pelvis, while 12 patients in lung and 15 in craniospinal irradiation (CSI). Patients were immobilized on the institutional protocol. Altogether 2686 megavoltage computed tomography images were analyzed with 672, 747, 622, 333, and 312 fractions, respectively, from brain, H and N, pelvis, lung, and CSI. Overall systematic and random errors were calculated in three translational and three rotational directions. Setup margins were evaluated using van Herk formula. The calculated margins were compared with the margins in the clinical use for various directions and sites. We found that the clinical isotropic margin of 3 mm was adequate for brain patients. However, in the longitudinal direction it was found to be out of margin by 0.7 mm. In H and N, the calculated margins were well within the isotropic margin of 5 mm which is in clinical use. In pelvis, the calculated margin was within the limits, 8.3 mm versus 10 mm only in longitudinal direction, however, in vertical and lateral directions the calculated margins were out of clinical margins 11 mm versus 10 mm, and 8.7 mm versus 7.0, mm respectively. In lung, all the calculated margins were well within the margins used clinically. In CSI, the variation was found in the middle spine in the longitudinal direction. The clinical margins used in our hospital are adequate enough for sites H and N, lung, and brain, however, for CSI and pelvis the margins were found to be out of clinical margins.
Collapse
Affiliation(s)
| | - Jamema V Swamidas
- Department of Medical Physics, Advanced Center for Treatment, Research, and Education in Cancer, Navi Mumbai, Maharashtra, India
| | - Jayprakash Agarwal
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Tejpal Gupta
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Sarbani G Laskar
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Umesh Mahantshetty
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Shrinivasan S Iyer
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Indrani U Mukherjee
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Shyam K Shrivastava
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
| | - Deepak D Deshpande
- Department of Medical Physics, Tata Memorial Hospital, Mumbai, Maharashtra, India
| |
Collapse
|
28
|
Mullaney T, Olausson K, Sharp L, Zackrisson B, Edvardsson D, Nyholm T. The influence of a department's psychosocial climate and treatment environment on cancer patients' anxiety during radiotherapy. Eur J Oncol Nurs 2016; 20:113-8. [DOI: 10.1016/j.ejon.2015.06.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2014] [Revised: 05/05/2015] [Accepted: 06/19/2015] [Indexed: 11/27/2022]
|
29
|
Huang CJ, Hou MF, Luo KH, Wei SY, Huang MY, Su SJ, Kuo HY, Yuan SSF, Chen GS, Chu-Sung Hu S, Chuang HY. RTOG, CTCAE and WHO criteria for acute radiation dermatitis correlate with cutaneous blood flow measurements. Breast 2015; 24:230-6. [DOI: 10.1016/j.breast.2015.01.008] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2014] [Revised: 12/09/2014] [Accepted: 01/28/2015] [Indexed: 11/28/2022] Open
|
30
|
McLaren N, Mackereth P, Hackman E, Holland F. Working out of the 'tool box': an exploratory study with complementary therapists in acute cancer care. Complement Ther Clin Pract 2014; 20:207-12. [PMID: 25486855 DOI: 10.1016/j.ctcp.2013.11.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Accepted: 11/12/2013] [Indexed: 11/18/2022]
Abstract
AIMS The aim of this research was to explore and capture complementary therapists' experiences of and preparation for working with patients in an acute cancer care setting. METHOD Semi structured interviews with therapists (n = 18) in an acute cancer hospital in the North West of England. The interviews were transcribed and analysed using thematic coding. RESULTS Key themes identified included; the need for a 'tool box' of skills that develop beyond those taught in initial training, building confidence when adapting these new skills in practice, helping patients to become empowered, the need to support carers, research evidence and resources issues, and the role of supervision. CONCLUSION This study was limited by being set in a single acute cancer site. Therapists valued having a 'tool box' but needed confidence and support to navigate the challenges of clinical practice.
Collapse
|
31
|
Towards the production of radiotherapy treatment shells on 3D printers using data derived from DICOM CT and MRI: preclinical feasibility studies. JOURNAL OF RADIOTHERAPY IN PRACTICE 2014. [DOI: 10.1017/s1460396914000326] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractBackground:Immobilisation for patients undergoing brain or head and neck radiotherapy is achieved using perspex or thermoplastic devices that require direct moulding to patient anatomy. The mould room visit can be distressing for patients and the shells do not always fit perfectly. In addition the mould room process can be time consuming. With recent developments in three-dimensional (3D) printing technologies comes the potential to generate a treatment shell directly from a computer model of a patient. Typically, a patient requiring radiotherapy treatment will have had a computed tomography (CT) scan and if a computer model of a shell could be obtained directly from the CT data it would reduce patient distress, reduce visits, obtain a close fitting shell and possibly enable the patient to start their radiotherapy treatment more quickly.Purpose:This paper focuses on the first stage of generating the front part of the shell and investigates the dosimetric properties of the materials to show the feasibility of 3D printer materials for the production of a radiotherapy treatment shell.Materials and methods:Computer algorithms are used to segment the surface of the patient’s head from CT and MRI datasets. After segmentation approaches are used to construct a 3D model suitable for printing on a 3D printer. To ensure that 3D printing is feasible the properties of a set of 3D printing materials are tested.Conclusions:The majority of the possible candidate 3D printing materials tested result in very similar attenuation of a therapeutic radiotherapy beam as the Orfit soft-drape masks currently in use in many UK radiotherapy centres. The costs involved in 3D printing are reducing and the applications to medicine are becoming more widely adopted. In this paper we show that 3D printing of bespoke radiotherapy masks is feasible and warrants further investigation.
Collapse
|
32
|
Middleton M, Nguyen H, Plank A, Jones M, Shannon D, Sisson T. An analysis of stabilisation for head and neck image guided IMRT. Radiography (Lond) 2014. [DOI: 10.1016/j.radi.2013.08.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
33
|
Leitzen C, Wilhelm-Buchstab T, Garbe S, Lütter C, Müdder T, Simon B, Schild H, Schüller H. Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems. Strahlenther Onkol 2013; 190:382-5. [DOI: 10.1007/s00066-013-0496-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Accepted: 10/24/2013] [Indexed: 12/25/2022]
|
34
|
Li G, Lovelock DM, Mechalakos J, Rao S, Della-Biancia C, Amols H, Lee N. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer. J Appl Clin Med Phys 2013; 14:243-54. [PMID: 24036878 PMCID: PMC5714571 DOI: 10.1120/jacmp.v14i5.4400] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Revised: 05/20/2013] [Accepted: 04/29/2013] [Indexed: 11/23/2022] Open
Abstract
To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an “open‐face” thermoplastic mask was evaluated using video‐based optical surface imaging (OSI) and kilovoltage (kV) X‐ray radiography. A three‐point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real‐time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15 minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open‐face and full‐head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open‐face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real‐time OSI. With the open‐face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre‐/post‐treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask‐locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open‐face and full‐head masks were found to be similar. Most (80%) of the volunteers preferred the open‐face mask to the full‐head mask, while claustrophobic patients could only tolerate the open‐face mask. The open‐face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open‐face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full‐head mask. PACS numbers: 87.19.xj, 87.63.L‐, 87.59.‐e, 87.55.tg, 87.55.‐x
Collapse
Affiliation(s)
- Guang Li
- Memorial Sloan-Kettering Cancer Center.
| | | | | | | | | | | | | |
Collapse
|
35
|
Hackman E, Tomlinson L, Mehrez A, Mackereth P. Reducing patient distress: a model for dementia care. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2013; 22:S13-S18. [PMID: 23448949 DOI: 10.12968/bjon.2013.22.sup2.s13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
More than 750000 people in the UK have some form of dementia; with a rise expected over the next 25 years. With early diagnosis of cancer, more patients with dementia will attend for cancer treatment. Immobilisation masks, used to ensure accurate head and neck radiotherapy, may trigger panic in patients, even without prior mental health problems. This single case study reports on the care provided to a patient with dementia and his carer, his wife Betty, during cancer treatment. Bert was diagnosed with dementia 10 years prior to his cancer diagnosis. The use of sedation appeared to trigger confusion rather than facilitate procedures. Bert's case illustrates how an individualised contract of care could be developed to help maximise interactions, ensure ongoing consent and maintain dignity during difficult and challenging medical procedures.
Collapse
|
36
|
Outhwaite JA, McDowall WR, Marquart L, Rattray G, Fielding A, Hargrave C. Training programme impact on thermoplastic immobilization for head and neck radiation therapy. Radiography (Lond) 2013. [DOI: 10.1016/j.radi.2012.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
37
|
Frequency and severity of skin reactions in patients with breast cancer undergoing adjuvant radiotherapy, the usefulness of two assessment instruments – A pilot study. Eur J Cancer 2011; 47:2665-72. [DOI: 10.1016/j.ejca.2011.06.039] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2011] [Revised: 06/19/2011] [Accepted: 06/17/2011] [Indexed: 11/19/2022]
|
38
|
Calming panic states in the Mould Room and beyond: A pilot complementary therapy head and neck cancer service. JOURNAL OF RADIOTHERAPY IN PRACTICE 2011. [DOI: 10.1017/s1460396911000148] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractPurpose: The service was piloted in response to requests for assistance with patients experiencing severe anxiety undergoing head and neck radiotherapy. This paper describes the aims of the service, interventions provided and the recorded responses of patients to the support given.Data: Information about who referred, patient demographics, the interventions provided and patient feedback (n = 112) was extracted from treatment records over a 15-month period.Findings: All referred patients successfully completed procedures and treatment. About 43 patients voluntarily disclosed past trauma, for example, sexual abuse, assault, childhood trauma, which they judged to have been linked to their claustrophobic responses. Advice and support was given to 40 patients also referred for smoking cessation; an additional three patients requested support when cravings returned.Conclusion: There is a paucity of information about the extent of the distress triggered by radiotherapy procedures and what interventions could be offered in practice. Further work is required to include an economic assessment and longer term effects on patient compliance with treatment and smoking cessation. Training needs for complementary therapists and radiotherapy staff at this centre were also identified; these are being addressed.
Collapse
|
39
|
Velec M, Waldron JN, O'Sullivan B, Bayley A, Cummings B, Kim JJ, Ringash J, Breen SL, Lockwood GA, Dawson LA. Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks. Int J Radiat Oncol Biol Phys 2010; 76:949-55. [PMID: 20056344 DOI: 10.1016/j.ijrobp.2009.07.004] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2009] [Revised: 07/01/2009] [Accepted: 07/01/2009] [Indexed: 10/20/2022]
|
40
|
Bednarz G, Machtay M, Werner-Wasik M, Downes B, Bogner J, Hyslop T, Galvin J, Evans J, Curran W, Andrews D. Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy. Med Phys 2009; 36:12-7. [PMID: 19235368 DOI: 10.1118/1.3030950] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Fractionated stereotactic radiotherapy (SRT) requires accurate and reproducible immobilization of the patient's head. This randomized study compared the efficacy of two commonly used forms of immobilization used for SRT. Two routinely used methods of immobilization, which differ in their approach to reproduce the head position from day to day, are the Gill-Thomas-Cosman (GTC) frame and the BrainLab thermoplastic mask. The GTC frame fixates on the patient's upper dentition and thus is in direct mechanical contact with the cranium. The BrainLab mask is a two-part masking system custom fitted to the front and back of the patient's head. After patients signed an IRB-approved informed consent form, eligible patients were randomized to either GTC frame or mask for their course of SRT. Patients were treated as per standard procedure; however, prior to each treatment a set of digital kilovolt images (ExacTrac, BrainLabAB, Germany) was taken. These images were fused with reference digitally reconstructed radiographs obtained from treatment planning CT to yield lateral, longitudinal, and vertical deviations of isocenter and head rotations about respective axes. The primary end point of the study was to compare the two systems with respect to mean and standard deviations using the distance to isocenter measure. A total of 84 patients were enrolled (69 patients evaluable with detailed positioning data). A mixed-effect linear regression and two-tiled t test were used to compare the distance measure for both the systems. There was a statistically significant (p < 0.001) difference between mean distances for these systems, suggesting that the GTC frame was more accurate. The mean 3D displacement and standard deviations were 3.17+1.95 mm for mask and 2.00+1.04 mm for frame. Both immobilization techniques were highly effective, but the GTC frame was more accurate. To optimize the accuracy of SRT, daily kilovolt image guidance is recommended with either immobilization system.
Collapse
Affiliation(s)
- Greg Bednarz
- Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Philadelphia, Pennsylvania 19107, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Court LE, Wolfsberger L, Allen AM, James S, Tishler RB. Clinical experience of the importance of daily portal imaging for head and neck IMRT treatments. J Appl Clin Med Phys 2008; 9:26-33. [PMID: 18716586 PMCID: PMC5722295 DOI: 10.1120/jacmp.v9i3.2756] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2007] [Accepted: 02/14/2008] [Indexed: 12/25/2022] Open
Abstract
The purpose of this study was to evaluate patient setup in head and neck IMRT using daily portal imaging. At our institution, orthogonal digital portal images are taken daily to check patient positioning prior to head and neck IMRT treatment. Isocenter misalignments are corrected using a couch shift (3mm action level). Therapists also compare the DRRs and portal images looking at points more distant from the isocenter, particular in the supraclavicular region, and re-position the patient's shoulders in the mask if considered necessary. The daily isocenter shifts (C2 region) and frequency of patient repositioning were investigated by review of record-and-verify records for 15 patients. The magnitude of the shoulder repositioning was evaluated for 10 of these patients by comparing portal images and plan DRRs for a point 8 cm inferior of isocenter (T2-T4). For all patients, pretreatment isocenter discrepancies 3mm or smaller were recorded for a median of 92.5% of fractions (range: 71.4 -100%). Patients were repositioned in the immobilization mask before treatment for a median of 14% of fractions (3-34%). Thirty percent of these were for shoulder shifts of 1cm or larger. Twenty percent of patients needed shoulder shifts of 1cm or more for more than 7/35 fractions, meaning that without setup based on daily imaging, parts of the CTV would have received less than 95% of the prescribed dose. In conclusion, with our current immobilization, isocenter positioning accuracy is excellent, while correct shoulder position is more variable, particularly for a small subset of patients. Frequent imaging of head and neck IMRT patients is essential to accurate delivery of therapy, with shoulder position an important factor.
Collapse
Affiliation(s)
- Laurence E Court
- Department of Radiation OncologyDana‐Farber / Brigham & Women's Cancer CenterBostonMAUSA
| | - Luciant Wolfsberger
- Department of Radiation OncologyDana‐Farber / Brigham & Women's Cancer CenterBostonMAUSA
| | - Aaron M Allen
- Department of Radiation OncologyDana‐Farber / Brigham & Women's Cancer CenterBostonMAUSA
| | - Steven James
- Department of Radiation OncologyDana‐Farber / Brigham & Women's Cancer CenterBostonMAUSA
| | - Roy B Tishler
- Department of Radiation OncologyDana‐Farber / Brigham & Women's Cancer CenterBostonMAUSA
| |
Collapse
|
42
|
Court LE, Allen A, Tishler R. Evaluation of the precision of portal-image-guided head-and-neck localization: An intra- and interobserver study. Med Phys 2007; 34:2704-7. [PMID: 17821978 DOI: 10.1118/1.2747050] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
There is increasing evidence that, for some patients, image-guided intensity-modulated radiation therapy (IMRT) for head-and-neck cancer patients may maintain target dose coverage and critical organ (e.g., parotids) dose closer to the planned doses than setup using lasers alone. We investigated inter- and intraobserver uncertainties in patient setup in head-and-neck cancer patients. Twenty-two sets of orthogonal digital portal images (from five patients) were selected from images used for daily localization of head-and-neck patients treated with IMRT. To evaluate interobserver variations, five radiation therapists compared the portal images with the plan digitally reconstructed radiographs and reported shifts for the isocenter (approximately C2) and for a supraclavicular reference point. One therapist repeated the procedure a month later to evaluate intraobserver variations. The procedure was then repeated with teams of two therapists. The frequencies for which agreement between the shift reported by the observer and the daily mean shift (average of all observers for a given image set) were less than 1.5 and 2.5 mm were calculated. Standard errors of measurement for the intra- and interobserver uncertainty (SEMintra and SEMinter) for the individual and teams were calculated. The data showed that there was very little difference between individual therapists and teams. At isocenter, 80%-90% of all reported shifts agreed with the daily average within 1.5 mm, showing consistency in the ways both individuals and teams interpret the images (SEMinter approximately 1 mm). This dropped to 65% for the supraclavicular point (SEMinter approximately 1.5 mm). Uncertainties increased for larger setup errors. In conclusion, image-guided patient positioning allows head-and-neck patients to be controlled within 3-4 mm. This is similar to the setup uncertainties found for most head-and-neck patients, but may provide some improvement for the subset of patients with larger setup uncertainties.
Collapse
Affiliation(s)
- Laurence E Court
- Department of Radiation Oncology, Dana-Farber/Brigham & Women's Cancer Center, Boston, Massachusetts 02115, USA.
| | | | | |
Collapse
|
43
|
Zhang L, Garden AS, Lo J, Ang KK, Ahamad A, Morrison WH, Rosenthal DI, Chambers MS, Zhu XR, Mohan R, Dong L. Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy. Int J Radiat Oncol Biol Phys 2006; 64:1559-69. [PMID: 16580505 DOI: 10.1016/j.ijrobp.2005.12.023] [Citation(s) in RCA: 152] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2005] [Revised: 12/02/2005] [Accepted: 12/09/2005] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyze three-dimensional setup uncertainties for multiple regions of interest (ROIs) in head-and-neck region. METHODS AND MATERIALS In-room computed tomography (CT) scans were acquired using a CT-on-rails system for 14 patients. Three separate bony ROIs were defined: C2 and C6 vertebral bodies and the palatine process of the maxilla. Translational shifts of 3 ROIs were calculated relative to the marked isocenter on the immobilization mask. RESULTS The shifts for all 3 ROIs were highly correlated. However, noticeable differences on the order of 2-6 mm existed between any 2 ROIs, indicating the flexibility and/or rotational effect in the head-and-neck region. The palatine process of the maxilla had the smallest right-left shifts because of the tight lateral fit in the face mask, but the largest superior-inferior movement because of in-plane rotation and variations in jaw positions. The neck region (C6) had the largest right-left shifts. The positioning mouthpiece was found effective in reducing variations in the superior-inferior direction. There was no statistically significant improvement for using the S-board (8 out of 14 patients) vs. the short face mask. CONCLUSIONS We found variability in setup corrections for different regions of head-and-neck anatomy. These relative positional variations should be considered when making setup corrections or designing treatment margins.
Collapse
Affiliation(s)
- Lifei Zhang
- Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Linthout N, Verellen D, Tournel K, Storme G. Six dimensional analysis with daily stereoscopic x-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks. Med Phys 2006; 33:504-13. [PMID: 16532958 DOI: 10.1118/1.2165417] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The safety margins used to define the Planning Target Volume (PTV) should reflect the accuracy of the target localization during treatment that comprises both the reproducibility of the patient positioning and the positional uncertainty of the target, so both the inter- and intrafraction motion of the target. Our first aim in this study was to determine the intrafraction motion of patients immobilized with a five-point thermoplastic mask for head and neck treatments. The five-point masks have the advantage that the patient's shoulders as well as the cranial part of the patient's head is covered with the thermoplastic material that improves the overall immobilization of the head and neck region of the patient. Thirteen patients were consecutively assigned to use a five-point thermoplastic mask. The patients were positioned by tracking of infrared markers (IR) fixed to the immobilization device and stereoscopic x-ray images were used for daily on-line setup verification. Repositioning was carried out prior to treatment as needed; rotations were not corrected. Movements during treatment were monitored by real-time IR tracking. Intrafraction motion and rotation was supplementary assessed by a six-degree-of-freedom (6-D) fusion of x-ray images, taken before and after all 385 treatments, with DRR images generated from the planning CT data. The latter evaluates the movement of the patient within the thermoplastic mask independent from the mask movement, where IR tracking evaluates the movement of the mask caused by patient movement in the mask. These two movements are not necessarily equal to each other. The maximum intrafraction movement detected by IR tracking showed a shift [mean (SD; range)] of -0.1(0.7; 6.0), 0.1(0.6; 3.6), -0.2(0.8;5.5) mm in the vertical, longitudinal, and lateral direction, respectively, and rotations of 0.0(0.2; 1.6), 0.0(0.2; 1.7) and 0.2(0.2; 2.4) degrees about the vertical, longitudinal, and lateral axis, respectively. The standard deviations and ranges found with the 6-D fusion demonstrate intrafraction patient displacements of -0.5(1.2; 7.4), 0.3(0.7; 5.3), 0.0(0.7; 5.7) mm in the vertical, longitudinal, and lateral direction, respectively, and rotations of -0.1(0.6; 4.1), 0.1(0.7; 8.3) and -0.2(0.8; 8.2) degrees about the vertical, longitudinal, and lateral axis, respectively. The 6-D fusions are considerably larger (p < 0.05) than detected by IR tracking. This indicates that the external marker tracking underestimates the magnitude of the actual intrafraction motion and rotation of the patient. The intrafraction motion detected for the patients immobilized with a conventional thermoplastic mask was relatively large. The feasibility to reduce this intrafraction movement by the application of alternative five-point thermoplastic mask types was evaluated as a second aim of this study. The preliminary results showed a clear reduction in the range, being an indication for the random movements, of both the intrafraction shift and rotation for both alternative mask types. The 6-D fusion is found a useful tool for a fast evaluation of the actual patient's intrafraction shift and rotation and shows the latter is not negligible and needs to be taken into account additional to the initial setup accuracy when determining the PTV margin.
Collapse
Affiliation(s)
- Nadine Linthout
- Department of Radiotherapy, Oncology Center, Academic Hospital-Free University, Brussels (AZ-VUB), Belgium.
| | | | | | | |
Collapse
|
45
|
Roques T, Dagless M, Tomes J. Randomized trial on two types of thermoplastic masks for patient immobilization during radiation therapy for head-and-neck cancer: In regard to Sharp et al. (Int J Radiat Oncol Biol Phys 2005;61:250–256). Int J Radiat Oncol Biol Phys 2005; 62:942; author reply 943. [PMID: 15936583 DOI: 10.1016/j.ijrobp.2005.03.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2005] [Accepted: 03/09/2005] [Indexed: 11/16/2022]
|