1
|
Bartlett GK, Njeh CF, Huang KC, DesRosiers C, Guo G. VMAT partial arc technique decreases dose to organs at risk in whole pelvic radiotherapy for prostate cancer when compared to full arc VMAT and IMRT. Med Dosim 2022; 48:8-15. [PMID: 36319515 DOI: 10.1016/j.meddos.2022.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 09/16/2022] [Indexed: 11/05/2022]
Abstract
Whole pelvic radiotherapy (WPRT) can sterilize microscopic lymph node metastases in treatment of prostate cancer. WPRT, compared to prostate only radiotherapy (PORT), is associated with increased acute gastrointestinal, and hematological toxicities. To further explore minimizing normal tissue toxicities associated with WPRT in definitive IMRT for prostate cancer, this planning study compared dosimetric differences between static 9-field-IMRT, full arc VMAT, and mixed partial-full arc VMAT techniques. In this retrospective study, 12 prostate cancer patients who met the criteria for WPRT were randomly selected for this study. The initial volume, PTV46, included the prostate, seminal vesicles, and pelvic nodes with margin and was prescribed to 4600 cGy. The cone-down volume, PTV78, included the prostate and proximal seminal vesicles with margin to a total dose of 7800 cGy. For each CT image set, 3 plans were generated for each of the PTVs: an IMRT plan, a full arc (FA) VMAT plan, and a mixed partial-full arc (PFA) VMAT plan, using 6MV photons energy. According to RTOG protocols none of the plans had a major Conformity Index (CI) violation by any of the 3 planning techniques. PFA plan had the best mean CI index of 1.00 and significantly better than IMRT (p = 0.03) and FA (p = 0.007). For equivalent PTV coverage, the average composite gradient index of the PFA plans was better than the IMRT and the FA plans with values 1.92, 2.03, and 2.01 respectively. The defference was statistically significant between PFA/IMRT and PFA/FA, with p- values of < 0.001. The IMRT plans and the PFA plans provided very similar doses to the rectum, bladder, sigmoid colon, and femoral heads, which were lower than the dose in the FA plans. There was a significant decrease in the mean dose to the rectum from 4524 cGy with the FA to 4182 cGy with the PFA and 4091 cGy with IMRT (p < 0.001). The percent of rectum receiving 4000 cGy was also the highest with FA at 66.1% compared to 49.9% (PFA) and 47.5% (IMRT). There was a significant decrease in the mean dose to the bladder from 3922 cGy (FA) to 3551 cGy (PFA) and 3612 cGy (IMRT) (p < 0.001). The percent of bladder receiving 4000 cGy was also the highest with FA at 45.4% compared to 36.6% (PFA) and 37.4% (IMRT). The average mean dose to the sigmoid colon decreased from 4177 cGy (FA) to 3893 cGy (PFA) and 3819 cGy (IMRT). The average mean dose to the femoral heads decreased from 2091 cGy (FA) to 2026 cGy (PFA) and 1987 cGy (IMRT). Considering the improvement in plan quality indices recorded in this study including the dose gradient and the dose to organs at risk, mixed partial-full arc plans may be the preferred VMAT treatment technique over full arc plans for prostate cancer treatments that include nodal volumes.
Collapse
Affiliation(s)
- Gregory K Bartlett
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Christopher F Njeh
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202.
| | - Ke C Huang
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Colleen DesRosiers
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Gordon Guo
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| |
Collapse
|
2
|
Impact of split X-jaw technique on target volume coverage and organ at risk sparing in prostate cancer: a comparative dosimetric study. JOURNAL OF RADIOTHERAPY IN PRACTICE 2022. [DOI: 10.1017/s1460396922000103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Introduction:
The Varian Trilogy linear accelerator’s multi-leaf collimator moves on a carriage with a maximum leaf span of 15 cm. The traditional open and limited X-jaw technique of volumetric-modulated arc radiotherapy (VMAT) yields a relatively compromised dose distribution within the planning target volume (PTV) region. This study aimed to determine whether the split X-jaw planning technique for VMAT improves plan quality regarding target dose coverage and organs at risk (OAR) sparing for PTVs that require a field size of more than 15 cm in the X-jaw direction in prostate cancer patients.
Method:
Computed tomography data sets from 15 patients with prostate cancer were enrolled in the study. Only the PTVs requiring a field size larger than 18 cm in the X-jaw position were considered, and a dose of 4500 cGy in 25 fractions was prescribed. For each case, three separate treatment plans were generated: open, limited and split X-jaw planning techniques with similar planning objectives
Results:
The split X-jaw technique resulted in statistically significant superior coverage of PTV when compared with the open (P < 0·0001) and limited methods (P < 0·001). The split technique delivered a lower dose to the OARs, although statistical significance could not be achieved. D2% (cGy) was lowest for the PTV in the split technique (4684·8 ± 18·16) and highest for the open technique (4710 ± 18·75), P < 0·001.
Conclusion:
The x-split jaw technique can replace the traditional open X-jaw practice of VMAT for PTVs requiring an X-jaw width of more than 15 cm in the Varian linear accelerator.
Collapse
|
3
|
Mirjolet C, Diallo I, Bertaut A, Veres C, Sargos P, Helfre S, Sunyach MP, Truc G, Le Pechoux C, Paumier A, Ducassou A, Jolnerovski M, Thariat J, Lapeyre M, Cordoba A, Mahé MA, Maingon P. Treatment related factors associated with the risk of breast radio-induced-sarcoma. Radiother Oncol 2022; 171:14-21. [DOI: 10.1016/j.radonc.2022.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 03/14/2022] [Accepted: 04/03/2022] [Indexed: 10/18/2022]
|
4
|
Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment. Med Dosim 2021; 47:48-53. [PMID: 34538693 DOI: 10.1016/j.meddos.2021.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/05/2021] [Accepted: 08/08/2021] [Indexed: 11/21/2022]
Abstract
The aim of this study was to compare the quality of dynamic wave arc (DWA) and coplanar volumetric modulated arc therapy (co-VMAT) plans for the treatment of localized prostate cancer. The planning target volume (PTV)-rectum, a section of the PTV comprising the PTV minus that of the rectum, received 78 Gy in 39 fractions as the mean dose to the PTV-rectum. The DWA and co-VMAT plans were generated for each patient using the RayStation treatment planning system for the Vero4DRT system. The PTV-rectum dose (D95%: the percent dose irradiating 95% of the volume), homogeneity index (HI), conformity index (CI), as well as doses to the bladder wall, rectum wall (V10-70 Gy: the percent volume receiving 10-70 Gy), and bilateral femoral heads of the DWA and co-VMAT plans were compared. The output monitor unit (MU) and delivery time obtained for each set of plans were also investigated. In terms of target coverage, the DWA plans provided an average D95% of 75.5 Gy, which was comparable to the co-VMAT-plan D95% of 75.2 Gy (p < 0.05). The HI was significantly better with the DWA. As for the DWA plans, the bladder-wall volume receiving 10, 20, 30, and 40 Gy (V10-40 Gy) was significantly smaller than that of the co-VMAT plans, and the volume of the rectal wall receiving 10 Gy (V10Gy) was significantly larger than that of the co-VMAT plans. The DWA plans yielded a reduced dose to the bilateral femoral heads compared with the co-VMAT plans (p < 0.05). The values of the CI and MU, and the delivery time exhibited no significant differences between the DWA and co-VMAT plans. The DWA plan is a feasible treatment option for prostate cancer radiotherapy.
Collapse
|
5
|
An institutional review: dosimetry comparison between simultaneous integrated boost IMRT and VMAT for prostate cancer. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396920000370] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
AbstractPurpose:A comparative study was performed about the plan parameters and quality indices between volumetric arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for the treatment of high-risk prostate cancer patients. The aim of this retrospective study was to compare the two methods of external beam radiotherapy IMRT and VMAT in terms of plan quality and efficacy.Material and method:Fifteen high-risk prostate patients were planned for radiotherapy using 6 MV photon. Three dose levels were contoured having Planning Tumour Volume 1 (PTV1 = 48 Gy), Planning Tumour Volume 2 (PTV2 = 57.6 Gy) and Planning Tumour Volume 3 (PTV3 = 60 Gy). Setup margins were given using the CHIP trial method. The prescribed PTV3 dose was 60 Gy in 20 fractions which is biologically equivalent to 74 Gy in 37 fractions using α/β = 3. In case of IMRT, seven fixed beam angles 30, 60, 105, 180, 255, 300 and 330 were used and the dose was optimised using the sliding window method. In case of rapid arc technique, one or two full arcs were used for dose optimisation while keeping all the dose constraints and other planning parameters same used in IMRT. The plan evaluation parameters and Organ at risks (OARs) doses were calculated using a dose volume histogram (DVH).Results:The average D2, D5, D95 and PTVmean for PTV3 were 61.22, 61.13, 58.12, 60.00 Gy and 62.41 62.24 59.53 61.12 Gy for IMRT and VMAT, respectively. The averages V60 for bladder and V30 for rectum were 22.81, 25 and 67, 65% for IMRT and VMAT, respectively. The average homogeneity index (HI), conformity index (CI) and gradient index (GI) were 1.04, 1.4833, 14.79 and 1.04, 1.704, 7.89 for IMRT and VMAT, respectively.Conclusion:VMAT takes less dose-delivery time and lesser number of monitoring units than IMRT, thus it compensates the intrafractional movements during dose delivery. The Dose GI in VMAT was much better than IMRT. This indicates sharper dose fall off near the normal tissue. No other major differences were observed in terms of plan evaluation parameters between IMRT and VMAT techniques. So, we conclude that VMAT technique is more efficient than IMRT in terms of plan quality and dose delivery.
Collapse
|
6
|
Kilian-Meneghin J, Ma T, Kumaraswamy L. Impact of prostate focused alignment on planned pelvic lymph node dose. J Appl Clin Med Phys 2021; 22:27-35. [PMID: 34231945 PMCID: PMC8292696 DOI: 10.1002/acm2.13092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 09/13/2019] [Accepted: 10/06/2019] [Indexed: 11/11/2022] Open
Abstract
Purpose Prostate patients with positive lymph node margins receive an initial course of 45 Gy to the planning target volume (PTV) comprised of prostate, seminal vesicles, and lymph nodes with a 1‐cm margin. The prostate is localized via implanted fiducial markers before each fraction is delivered using portal‐imaging. However, the pelvic lymph nodes are affixed to the bony anatomy and are not mobile in concert with the prostate. The aim of this study was to determine whether a significant difference in pelvic lymph node coverage exists between planned and delivered external beam therapy treatments for these patients. Methods The recorded prostate motions were gathered for 19 patients; conjointly the pelvic lymph node motions were determined by manual registration of the bony anatomy in the kV‐images. The difference between the prostate and the bony anatomy coordinates was input into Eclipse as field shifts to represent the deviation in planned vs delivered pelvic lymph node coverage. Results Structure volume at V(100) was recorded for each patient for two structures: summed pelvic lymph nodes (LN CTV) and pelvic lymph nodes +1 cm margin (LN PTV) to express their contribution to the PTV. For the LN PTV, the average difference between the planned coverage and calculated delivered coverage was 3.5%, with a paired t‐test value of P = 0.005. Based upon bony anatomy registration, 26% of patients received less than 95% dose coverage using V(100) criteria for LN PTV. Dose value differences between the two plans at minimum were 6.96 ± 6.23 Gy, at mean were 0.54 ± 0.40 Gy, and at maximum were 0.10 ± 0.29 Gy. For the LN CTV, the average difference between the planned coverage and calculated delivered coverage was 1%, with a paired t‐test value of P = 0.53. Conclusions The results indicate a significant difference exists between the planned coverage and calculated delivered coverage for the LN PTV. There was no significant difference found for the LN CTV. We conclude that lymph node motion must be considered with the prostate motion when aligning patients before each fraction.
Collapse
Affiliation(s)
| | - Tianjun Ma
- Roswell Park Comprehensive Cancer Center, Buffalo, NY, USA
| | | |
Collapse
|
7
|
Kang S, Kim KH, Kang SW, Shin DS, Lee S, Chung JB. Evaluation of a new foetal shielding device for pregnant brain tumour patients. Radiat Oncol 2021; 16:109. [PMID: 34120633 PMCID: PMC8201726 DOI: 10.1186/s13014-021-01836-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 06/10/2021] [Indexed: 11/29/2022] Open
Abstract
Background The present study aimed to propose a new foetal shielding device for pregnant cancer patients to reduce the foetal dose associated with treatment techniques using multiple gantry angles, such as intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT). Methods Three shielding structures were designed to minimise the scattered and leaked radiation from various gantry angles and radiation scattering within the patient. The base-plate part that can be placed on the treatment couch was designed to reduce the scattered and leaked radiation generated at gantry angles located near 180°. A body shielding part that can cover the lower chest and abdomen was designed, and a neck-shielding structure was added to reduce the internal and external radiation scattering from the treatment area. Evaluation plans were generated to assess the foetal dose reduction by the foetal shielding device in terms of the shielding material thickness, distance from the field edge, and shielding component using the flattened 6 MV photon beam (6MV) and flattening filter-free 6 MV photon beam (6MV-FFF). In addition, the effectiveness of the foetal shielding device was evaluated in a pregnant brain tumour patient. Results The shielding material consisting of three parts was placed on frames composed of four arch shapes with a vertical curved structure, connection bar at the top position, and base plate. Each shielding part resulted in reductions in the radiation dose according to the treatment technique, as the thickness of the shielding material increased and the foetal dose decreased. In addition, a foetal dose reduction of approximately 50% was confirmed at 50 cm from the field edge by using the designed shielding device in most delivery techniques. In patients, the newly designed shielding structures can effectively eliminate up to about 49% of the foetal dose generated from various gantry angles used in VMAT or IMRT. Conclusions We designed a foetal shielding device consisting of three parts to effectively reduce the dose delivered to the foetus, and evaluated the device with various treatment techniques for a pregnant patient with brain tumour. The foetal shielding device shielded the scattered/leaked radiation from the treatment machine, and also effectively reduced internal scattering from the treatment area in the patient.
Collapse
Affiliation(s)
- Seonghee Kang
- Department of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, 13620, Gyeonggi-do, Korea.,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Kyeong-Hyeon Kim
- Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Sang-Won Kang
- Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Dong-Seok Shin
- Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Seungwan Lee
- Department of Radiological Science, Konyang University, Daejeon, Korea
| | - Jin-Beom Chung
- Department of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, 13620, Gyeonggi-do, Korea.
| |
Collapse
|
8
|
Jensen PJ, Zhang J, Koontz BF, Wu QJ. A Novel Machine Learning Model for Dose Prediction in Prostate Volumetric Modulated Arc Therapy Using Output Initialization and Optimization Priorities. Front Artif Intell 2021; 4:624038. [PMID: 33969289 PMCID: PMC8103207 DOI: 10.3389/frai.2021.624038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 03/18/2021] [Indexed: 11/20/2022] Open
Abstract
Treatment planning for prostate volumetric modulated arc therapy (VMAT) can take 5–30 min per plan to optimize and calculate, limiting the number of plan options that can be explored before the final plan decision. Inspired by the speed and accuracy of modern machine learning models, such as residual networks, we hypothesized that it was possible to use a machine learning model to bypass the time-intensive dose optimization and dose calculation steps, arriving directly at an estimate of the resulting dose distribution for use in multi-criteria optimization (MCO). In this study, we present a novel machine learning model for predicting the dose distribution for a given patient with a given set of optimization priorities. Our model innovates upon the existing machine learning techniques by utilizing optimization priorities and our understanding of dose map shapes to initialize the dose distribution before dose refinement via a voxel-wise residual network. Each block of the residual network individually updates the initialized dose map before passing to the next block. Our model also utilizes contiguous and atrous patch sampling to effectively increase the receptive fields of each layer in the residual network, decreasing its number of layers, increasing model prediction and training speed, and discouraging overfitting without compromising on the accuracy. For analysis, 100 prostate VMAT cases were used to train and test the model. The model was evaluated by the training and testing errors produced by 50 iterations of 10-fold cross-validation, with 100 cases randomly shuffled into the subsets at each iteration. The error of the model is modest for this data, with average dose map root-mean-square errors (RMSEs) of 2.38 ± 0.47% of prescription dose overall patients and all optimization priority combinations in the patient testing sets. The model was also evaluated at iteratively smaller training set sizes, suggesting that the model requires between 60 and 90 patients for optimal performance. This model may be used for quickly estimating the Pareto set of feasible dose objectives, which may directly accelerate the treatment planning process and indirectly improve final plan quality by allowing more time for plan refinement.
Collapse
Affiliation(s)
- P James Jensen
- Department of Radiation Oncology, Duke Cancer Institute, Durham, NC, United States
| | - Jiahan Zhang
- Department of Radiation Oncology, Duke Cancer Institute, Durham, NC, United States
| | - Bridget F Koontz
- Department of Radiation Oncology, Duke Cancer Institute, Durham, NC, United States
| | - Q Jackie Wu
- Department of Radiation Oncology, Duke Cancer Institute, Durham, NC, United States
| |
Collapse
|
9
|
Adaptive sequential plan-on-plan optimization during prostate-specific antigen response guided radiotherapy of recurrent prostate cancer. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 18:5-10. [PMID: 34258401 PMCID: PMC8254191 DOI: 10.1016/j.phro.2021.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 02/24/2021] [Accepted: 03/12/2021] [Indexed: 12/24/2022]
Abstract
Background Treatment adaptation based on tumour biomarker response during radiotherapy of prostate cancer, could be used for both escalation and de-escalation of radiation doses and volumes. To execute an adaptation involving extension of treatment volumes during radiation can however be restricted by the doses already delivered. The aim of this work was to develop a treatment planning method that addresses this challenge. Material and methods A volumetric-modulated-arc-therapy (VMAT) planning method with sequential plan-on-plan optimization was developed for a prospective phase II trial including 100 patients on salvage radiotherapy (SRT) for prostate cancer recurrence. A treatment adaptation was performed after five weeks of SRT based on prostate-specific antigen response during this phase of the treatment. This involved extension of treatment volumes for non-responders (n = 64) to include pelvic lymph nodes and boost to 68Gallium-Prostate-Specific-Membrane-Antigen-Positron-Emission-Tomography positive lesions. This method was evolved by introducing an EQD2 (equivalent dose in 2.0 Gy fractions) correction of the base plan for improved dose coverage. Results All dose-volume criteria for target coverage were met for the non-responders when based on physical dose. An EQD2 correction of the base plan for non-responders, implemented for the final 29 patients, led to a statistically significant improvement in dose coverage as compared to the 35 patients treated without EQD2 correction. Conclusions This is to our knowledge the only study presented on biomarker-guided sequential VMAT radiotherapy using a plan-on-plan technique in the pelvis. By using a biologically adapted technique an improved target coverage was achieved without compromising doses to organs at risk.
Collapse
|
10
|
Chao M, Coburn N, Cosgriff E, Brown C, Van Tilburg K, Hayden A. A predictive model for determining rectum and bladder dose constraints in prostate volumetric modulated arc therapy. Med Dosim 2021; 46:269-273. [PMID: 33726940 DOI: 10.1016/j.meddos.2021.02.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 11/22/2020] [Accepted: 02/05/2021] [Indexed: 10/21/2022]
Abstract
Generic dose-volume constraints of the rectum/bladder (R/B) are used in inverse planning to reduce doses to these organs for patients undergoing prostate radiotherapy. A retrospective study was undertaken to assess correlations between the overlap of the R/B with the planning target volume (PTV) and the dose received during planning to organs at risk (OARs). Data for 105 prostate cancer patients who had volumetric modulated arc therapy (VMAT) to the intact prostate and proximal seminal vesicles at Nepean Cancer Care Centre from 2011 to 2015 were analyzed. R/B volume, R/B-PTV overlap volume, and R/B-PTV overlap percent metrics were collected with VMAT planning objectives. Characteristics were evaluated for correlation with different planning outcomes. The percentage overlap between the R/B and PTV were highly correlated to the doses to the relevant OAR, with a coefficient of determination (R2) of 0.63 for the rectum volume percentage receiving more than 75 Gy (RV75Gy) and R2 of 0.91 for the bladder volume percentage receiving more than 70 Gy (BV70Gy). We identified a cut-off value of 10.14% (sensitivity 84.62%, specificity 80.43%) as predictive of RV75Gy < 10% and a cut-off of 7.95% (sensitivity 97.62%, specificity 92.06%) as predictive of BV70Gy < 15%. A 95% prediction interval assisted in identifying individualized R/B planning goals. The R/B-PTV percentage overlap has a high reliability in estimating sparing of the R/B. This prediction model can be used to improve planning efficiency and create customised automated OAR planning goals in prostate VMAT plans. By doing this, the radiation doses received by these OARs can be minimized.
Collapse
Affiliation(s)
- Menglei Chao
- Nepean Cancer Care Centre, Nepean Hospital, Kingswood, New South Wales, 2747, Australia.
| | - Natalie Coburn
- Nepean Cancer Care Centre, Nepean Hospital, Kingswood, New South Wales, 2747, Australia
| | - Eireann Cosgriff
- Nepean Cancer Care Centre, Nepean Hospital, Kingswood, New South Wales, 2747, Australia
| | - Chris Brown
- NHMRC Clinical Trials Centre, The University of Sydney, Campbelltown, New South Wales, Australia
| | - Kevin Van Tilburg
- Nepean Cancer Care Centre, Nepean Hospital, Kingswood, New South Wales, 2747, Australia
| | - Amy Hayden
- Nepean Cancer Care Centre, Nepean Hospital, Kingswood, New South Wales, 2747, Australia; Crown Princess Mary Cancer Centre, Westmead Hospital, Westmead, New South Wales, Australia
| |
Collapse
|
11
|
VMAT treatment plan acceptability and quality assurance study for prostate cancer in radiotherapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396919001031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractAim:The aim of this work was to study the acceptability of plans prepared for prostate patients treated by volumetric modulated arc therapy (VMAT) with the vision to evaluate the quality of plans and test pre-treatment quality assurance (QA).Material methods:VMAT plans of 35 patients, planned on the Eclipse Treatment Planning System (Aria 15), were included in the study. Plan acceptability was checked using statistical analysis, which includes homogeneity index, radical and median homogeneity index, coverage and uniformity index. Dose–volume histograms (DVH) of the plans were also studied to check prescribed dose (PD), Dmax, Dmin, D5 and D95. Portal dosimetry was also done by gamma analysis using 3%/3 mm criterion. SD and mean SD error were also calculated and analysed.Results:Statistical analysis showed a mean HI of 1·054, coverage 0·959, UI 1·055, mDHI 0·962 and rDHI 0·866. SD of HI, coverage, UI, mDHI and rDHI was 0·019, 0·019, 0·014, 0·013 and 0·030, respectively. From the DVHs, mean of D5, D95, Dmin and Dmax was calculated at 6,252·9, 5,757·4, 6,413·3 and 5,657·7 cGy, respectively, with a prescribed dose of 6,000 cGy. According to gamma analysis, area gamma < 1 was 99·12% with a tolerance limit of 95%, maximum gamma was 1·466 with a tolerance limit of 3·5, average gamma was 0·388 with a tolerance limit of 0·5, area gamma > 1·2 was 0·242% with a tolerance limit of 0·5%, maximum dose difference was 0·6 with a tolerance limit of 1·0 and average dose difference was 0·029 with a tolerance limit of 0·2.Conclusion:All three computations showed the results to be within acceptable limits. VMAT possesses a unique feature of delivering the whole treatment with only two rotations of the gantry. VMAT has an improved efficiency of delivery for equivalent dosimetric quality.
Collapse
|
12
|
Altundal Y, Cifter F, Mu G, Lee J, Wu EJ, Yeung V, Katz A. Prostate Stereotactic Body Radiation Therapy With Halcyon 2.0: Treatment Plans Comparison Based on RTOG 0938 Protocol. Cureus 2020; 12:e11660. [PMID: 33391899 PMCID: PMC7772112 DOI: 10.7759/cureus.11660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Purpose The aim of this study is to investigate the feasibility of prostate stereotactic body radiation therapy treatment with a newly developed Varian HalcyonTM 2.0 machine by comparing radiotherapy plans with previously delivered CyberKnife G4 plans created with the previous version of CyberKnife Treatment Planning System Multiplan 4.6.1. Methods Fifteen previously treated prostate stereotactic body radiation therapy treatment CyberKnife plans were re-planned retrospectively according to the Radiation Therapy Oncology Group 0938 protocol on a HalcyonTM 2.0 machine with a prescription of 3625 cGy in five fractions. Results All re-plans on a HalcyonTM 2.0 were able to meet the Radiation Therapy Oncology Group 0938 protocol goals and constraints. The re-plans decreased the maximum dose to skin and urethra, mean doses to the bladder and rectum, and also improve the conformity index and the Planning Target Volume coverage. However, D1cc to the rectum, D1cc and D10% to the bladder increased with no statistically significant differences (p > 0.05) with the re-plans. Conclusion The HalcyonTM 2.0 can generate stereotactic body radiation therapy treatment prostate plans created based on the Radiation Therapy Oncology Group 0938 protocol by delivering adequate coverage to the target while sparing healthy tissues.
Collapse
Affiliation(s)
- Yücel Altundal
- Medical Physics, Flushing Radiation Oncology Services, Flushing, USA
| | - Fulya Cifter
- Medical Physics, Precess Medical, Short Hills, USA
| | - Guangwei Mu
- Medical Physics, Flushing Radiation Oncology Services, Flushing, USA
| | - James Lee
- Radiation Oncology, Flushing Radiation Oncology Services, Flushing, USA
| | - Elisa J Wu
- Radiation Oncology, Flushing Radiation Oncology Services, Flushing, USA
| | - Vincent Yeung
- Radiation Oncology, Flushing Radiation Oncology Services, Flushing, USA
| | - Alan Katz
- Radiation Oncology, St. Francis Hospital, Roslyn, USA
| |
Collapse
|
13
|
Dosimetric characteristics of VMAT plans with respect to a different increment of gantry angle size for Ca cervix. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s146039692000093x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractAim:We have investigated the influence in volumetric-modulated arc therapy (VMAT) plans by a sequence of increment of gantry angle (IGA) in definitive radiotherapy treatment for cervical cancer. The plans are quantitatively analysed in terms of conformity index (CI), heterogeneity index (HI), dose–gradient index (DGI), target coverage (TC) by prescription dose, monitor unit (MU) usage, control points (CPs) and dose to organs.Materials and Methods:In this retrospective study, we selected 27 patients with cervical cancer having aged between 54 and 69. All the patients enrolled in this study were at T3N1M0 stage of cervical cancer. The prescription dose to planning target volume (PTV) was 50 Gy and was administered in 2 Gy/fraction through VMAT technique. VMAT plans were optimised by varying the parameter ‘IGA’ as 10, 20, 30 and 40°.Results:Homogenous dose distribution within PTV and TC by prescription dose was significantly enhanced (p < 0·05) with larger IGA. The difference between volume receiving 15 Gy (V15Gy) in bowel was up to 10% with larger IGA (30 and 40°) and V25Gy in femoral head was up to 3% with smaller IGA (10 and 20°). CPs were enhanced and MU usage was reduced with larger IGA (30 and 40°). IGA 40° had reduced the MU usage than IGA 30° but the CI and DGI were compromised due to large MLC field segments.Conclusion:This study recommends that the larger IGA could yield better results when the number of sectors is even, for a cervical cancer patient. However, more data from more patients need to be obtained and analysed to make this an evidence-based hypothesis.
Collapse
|
14
|
Intensity-Modulated Radiation Therapy Optimization for Acceptable and Remaining-One Unacceptable Dose-Volume and Mean-Dose Constraint Planning. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2020; 2020:3096067. [PMID: 32963584 PMCID: PMC7492683 DOI: 10.1155/2020/3096067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 06/15/2020] [Accepted: 06/22/2020] [Indexed: 11/17/2022]
Abstract
We give a novel approach for obtaining an intensity-modulated radiation therapy (IMRT) optimization solution based on the idea of continuous dynamical methods. The proposed method, which is an iterative algorithm derived from the discretization of a continuous-time dynamical system, can handle not only dose-volume but also mean-dose constraints directly in IMRT treatment planning. A theoretical proof for the convergence to an equilibrium corresponding to the desired IMRT planning is given by using the Lyapunov stability theorem. By introducing the concept of "acceptable," which means the existence of a nonempty set of beam weights satisfying the given dose-volume and mean-dose constraints, and by using the proposed method for an acceptable IMRT planning, one can resolve the issue that the objective and evaluation are different in the conventional planning process. Moreover, in the case where the target planning is totally unacceptable and partly acceptable except for one group of dose constraints, we give a procedure that enables us to obtain a nearly optimal solution close to the desired solution for unacceptable planning. The performance of the proposed approach for an acceptable or unacceptable planning is confirmed through numerical experiments simulating a clinical setup.
Collapse
|
15
|
Role of fiducial markers in the assessment of prostate bed motion in post-prostatectomy patients treated with volumetric modulated arc therapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396919000785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractAim:Accurate localisation of target position is crucial when using techniques with sharp dose fall off such as volumetric modulated arc therapy (VMAT). Gold seed fiducial markers have been used for target localisation in image-guided radiation therapy for various tumors including intact prostate cancers. However, their role for target localisation in post-prostatectomy radiotherapy is unclear. This study was undertaken to determine the feasibility and effectiveness of gold seed fiducial markers in patients undergoing prostate bed VMAT.Materials and methods:The institutional radiation oncology database was used to analyse the treatment data of 18 post-prostatectomy patients with implanted gold seed fiducial markers. The shifts of the fiducial markers were reviewed, tabulated and statistically analysed.Results:Three hundred and eighty-six orthogonal pair images for 18 patients were reviewed. Specifically, the average gold seed fiducial shifts were 0·34 cm in the superior–inferior (S/I) axis (0·31 SD), 0·31 cm (0·29 SD) in the anterior–posterior (A/P) axis and 0·28 cm (0·25 SD) in the lateral axis (R/L). As a result, the 95% probability of fiducial marker displacement was 0·96 cm in the S/I, 0·89 cm in the A/P and 0·78 cm in the R/L axes. The most frequent shifts occurred in the inferior, left and posterior directions. The percentage of shifts more than 0·5 cm were 19·74, 21·56 and 12·47% for the S/I, A/P and R/L axes, respectively.Conclusion:In the absence of fiducial markers, non-uniform planning target volume (PTV) margins of 1 cm for S/I, 9 mm for A/P and 8 mm for the lateral direction are necessary for target localisation in post-prostatectomy radiotherapy. By improving prostate bed localisation, gold seed fiducial markers can decrease PTV margins, reduce normal tissue radiation exposure and allow for dose-escalated and/or hypofractionated radiotherapy to be considered in appropriate clinical scenarios.
Collapse
|
16
|
Haciislamoglu E, Gungor G, Aydin G, Canyilmaz E, Guler OC, Zengin AY, Yenice KM. Estimation of secondary cancer risk after radiotherapy in high-risk prostate cancer patients with pelvic irradiation. J Appl Clin Med Phys 2020; 21:82-89. [PMID: 32671989 PMCID: PMC7497909 DOI: 10.1002/acm2.12972] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 05/13/2020] [Accepted: 06/22/2020] [Indexed: 12/21/2022] Open
Abstract
We aimed to estimate the risk of secondary cancer after radiotherapy (RT) in high‐risk prostate cancer (HRPC) patients with pelvic irradiation. Computed tomography data of five biopsy‐proven HRPC patients were selected for this study. Two different planning target volumes (PTV1 and PTV2) were contoured for each patient. The PTV1 included the prostate, seminal vesicles, and pelvic lymphatics, while the PTV2 included only the prostate and seminal vesicles. The prescribed dose was 54 Gy for the PTV1 with a sequential boost (24 Gy for the PTV2). Intensity‐modulated RT (IMRT) and volumetric modulated arc therapy (VMAT) techniques were used to generate treatment plans with 6 and 10 MV photon energies with the flattening filter (FF) or flattening filter‐free (FFF) irradiation mode. The excess absolute risks (EARs) were calculated and compared for the bladder, rectum, pelvic bone, and soft tissue based on the linear‐exponential, plateau, full mechanistic, and specific mechanistic sarcoma dose‐response model. According to the models, all treatment plans resulted in similar risks of secondary bladder or rectal cancer and pelvic bone or soft tissue sarcoma except for the estimated risk of the bladder according to the full mechanistic model using IMRT(6MV;FF) technique compared with VMAT techniques with FFF options. The overall estimation of EAR indicated that the radiation‐induced cancer risk due to RT in HRPC was lower for bladder than the rectum. EAR values ranged from 1.47 to 5.82 for bladder and 6.36 to 7.94 for rectum, depending on the dose–response models used. The absolute risks of the secondary pelvic bone and soft tissue sarcoma were small for the plans examined. We theoretically predicted the radiation‐induced secondary cancer risk in HRPC patients with pelvic irradiation. Nevertheless, prospective clinical trials, with larger patient cohorts with a long‐term follow‐up, are needed to validate these model predictions.
Collapse
Affiliation(s)
- Emel Haciislamoglu
- Department of Radiation Oncology, Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey
| | - Gorkem Gungor
- Department of Radiation Oncology, Acibadem University, Istanbul, Turkey
| | - Gokhan Aydin
- Department of Radiation Oncology, Acibadem University, Istanbul, Turkey
| | - Emine Canyilmaz
- Department of Radiation Oncology, Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey
| | - Ozan Cem Guler
- Department of Radiation Oncology, Faculty of Medicine, Baskent University, Adana, Turkey
| | - Ahmet Yasar Zengin
- Department of Radiation Oncology, Kanuni Research and Education Hospital, Trabzon, Turkey
| | - Kamil Mehmet Yenice
- Department of Radiation and Cellular Oncology, University of Chicago Medicine, Chicago, IL, USA
| |
Collapse
|
17
|
Park JI, Lee S, Kim IH, Ye SJ. Artifact-free CT images for electron beam therapy using a patient-specific non metallic shield. Phys Med 2020; 75:92-99. [PMID: 32559651 DOI: 10.1016/j.ejmp.2020.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 05/10/2020] [Accepted: 06/01/2020] [Indexed: 10/24/2022] Open
Abstract
Patient's CT images taken with metallic shields for radiotherapy suffer from artifacts. Furthermore, the treatment planning system (TPS) has a limitation on accurate dose calculations for high density materials. In this study, a Monte Carlo (MC)-based method was developed to accurately evaluate the dosimetric effect of the metallic shield. Two patients with a commercial tungsten shield of lens and two patients with a custom-made lead shield of lip were chosen to produce their non-metallic dummy shields using 3D scanner and printer. With these dummy shields, we generated artifact-free CT images. The maximum CT number allowed in TPS was assigned to metallic shields. MC simulations with real material information were carried out. In addition, clinically relevant dose-volumetric parameters were calculated for the comparison between MC and TPS. Relative dosimetry was performed using radiochromic films. The dose reductions below metallic structures were shown on MC dose distributions, but not evident on TPS dose distributions. The differences in dose-volumetric parameters of PTV between TPS and MC for eye shield cases were not clearly shown. However, the mean dose of lens from TPS and MC was different. The MC results were in superior agreement with measured data in relative dosimetry. The lens dose could be overestimated by TPS. The differences in dose-volumetric parameters of PTV between TPS and MC were generally larger in lip cases than in eye cases. The developed method is useful in predicting the realistic dose distributions around the organs blocked by the metallic shields.
Collapse
Affiliation(s)
- Jong In Park
- Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, South Korea.
| | - Sangmin Lee
- Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, South Korea
| | - Il Han Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, South Korea
| | - Sung-Joon Ye
- Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, South Korea; Department of Radiation Oncology, Seoul National University Hospital, Seoul, South Korea; Robotics Research Laboratory for Extreme Environment, Advanced Institutes of Convergence Technology, Seoul National University, Suwon, Gyeonggi-do, South Korea
| |
Collapse
|
18
|
Urethra-Sparing Stereotactic Body Radiation Therapy for Prostate Cancer: Quality Assurance of a Randomized Phase 2 Trial. Int J Radiat Oncol Biol Phys 2020; 108:1047-1054. [PMID: 32535161 DOI: 10.1016/j.ijrobp.2020.06.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 05/12/2020] [Accepted: 06/01/2020] [Indexed: 02/05/2023]
Abstract
PURPOSE To present the radiation therapy quality assurance results from a prospective multicenter phase 2 randomized trial of short versus protracted urethra-sparing stereotactic body radiation therapy (SBRT) for localized prostate cancer. METHODS AND MATERIALS Between 2012 and 2015, 165 patients with prostate cancer from 9 centers were randomized and treated with SBRT delivered either every other day (arm A, n = 82) or once a week (arm B, n = 83); 36.25 Gy in 5 fractions were prescribed to the prostate with (n = 92) or without (n = 73) inclusion of the seminal vesicles (SV), and the urethra planning-risk volume received 32.5 Gy. Patients were treated either with volumetric modulated arc therapy (VMAT; n = 112) or with intensity modulated radiation therapy (IMRT; n = 53). Deviations from protocol dose constraints, planning target volume (PTV) homogeneity index, PTV Dice similarity coefficient, and number of monitor units for each treatment plan were retrospectively analyzed. Dosimetric results of VMAT versus IMRT and treatment plans with versus without inclusion of SV were compared. RESULTS At least 1 major protocol deviation occurred in 51 patients (31%), whereas none was observed in 41. Protocol violations were more frequent in the IMRT group (P < .001). Furthermore, the use of VMAT yielded better dosimetric results than IMRT for urethra planning-risk volume D98% (31.1 vs 30.8 Gy, P < .0001), PTV D2% (37.9 vs 38.7 Gy, P < .0001), homogeneity index (0.09 vs 0.10, P < .0001), Dice similarity coefficient (0.83 vs 0.80, P < .0001), and bladder wall V50% (24.5% vs 33.5%, P = .0001). To achieve its goals volumetric modulated arc therapy required fewer monitor units than IMRT (2275 vs 3378, P <.0001). The inclusion of SV in the PTV negatively affected the rectal wall V90% (9.1% vs 10.4%, P = .0003) and V80% (13.2% vs 15.7%, P = .0003). CONCLUSIONS Protocol deviations with potential impact on tumor control or toxicity occurred in 31% of patients in this prospective clinical trial. Protocol deviations were more frequent with IMRT. Prospective radiation therapy quality assurance protocols should be strongly recommended for SBRT trials to minimize potential protocol deviations.
Collapse
|
19
|
Murakami Y, Magome T, Matsumoto K, Sato T, Yoshioka Y, Oguchi M. Fully automated dose prediction using generative adversarial networks in prostate cancer patients. PLoS One 2020; 15:e0232697. [PMID: 32365088 PMCID: PMC7197852 DOI: 10.1371/journal.pone.0232697] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 04/19/2020] [Indexed: 12/20/2022] Open
Abstract
Purpose Although dose prediction for intensity modulated radiation therapy (IMRT) has been accomplished by a deep learning approach, delineation of some structures is needed for the prediction. We sought to develop a fully automated dose-generation framework for IMRT of prostate cancer by entering the patient CT datasets without the contour information into a generative adversarial network (GAN) and to compare its prediction performance to a conventional prediction model trained from patient contours. Methods We propose a synthetic approach to translate patient CT datasets into a dose distribution for IMRT. The framework requires only paired-images, i.e., patient CT images and corresponding RT-doses. The model was trained from 81 IMRT plans of prostate cancer patients, and then produced the dose distribution for 9 test cases. To compare its prediction performance to that of another trained model, we created a model trained from structure images. Dosimetric parameters for the planning target volume (PTV) and organs at risk (OARs) were calculated from the generated and original dose distributions, and mean differences of dosimetric parameters were compared between the CT-based model and the structure-based model. Results The mean differences of all dosimetric parameters except for D98% and D95% for PTV were within approximately 2% and 3% of the prescription dose for OARs in the CT-based model, while the differences in the structure-based model were within approximately 1% for PTV and approximately 2% for OARs, with a mean prediction time of 5 seconds per patient. Conclusions Accurate and rapid dose prediction was achieved by the learning of patient CT datasets by a GAN-based framework. The CT-based dose prediction could reduce the time required for both the iterative optimization process and the structure contouring, allowing physicians and dosimetrists to focus their expertise on more challenging cases.
Collapse
Affiliation(s)
- Yu Murakami
- Graduate Division of Health Sciences, Komazawa University, Komazawa, Setagaya-ku, Tokyo, Japan
- Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Ariake, Koto-ku, Tokyo, Japan
| | - Taiki Magome
- Graduate Division of Health Sciences, Komazawa University, Komazawa, Setagaya-ku, Tokyo, Japan
- * E-mail:
| | - Kazuki Matsumoto
- Graduate Division of Health Sciences, Komazawa University, Komazawa, Setagaya-ku, Tokyo, Japan
| | - Tomoharu Sato
- Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Ariake, Koto-ku, Tokyo, Japan
| | - Yasuo Yoshioka
- Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Ariake, Koto-ku, Tokyo, Japan
| | - Masahiko Oguchi
- Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Ariake, Koto-ku, Tokyo, Japan
| |
Collapse
|
20
|
Soda R, Hatanaka S, Hariu M, Shimbo M, Yamano T, Nishimura K, Kondo S, Utsumi N, Takahashi T. Evaluation of geometrical uncertainties on localized prostate radiotherapy of patients with bilateral metallic hip prostheses using 3D-CRT, IMRT and VMAT: A planning study. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:243-254. [PMID: 31985486 DOI: 10.3233/xst-190598] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
OBJECTIVE Since most radiation treatment plans are based on computed tomography (CT) images, which makes it difficult to define the targeted tumor volume located near a metal implant, this study aims to evaluate and compare three treatment plans in order to optimally reduce geometrical uncertainty in external radiation treatment of localized prostate cancer. METHODS Experimental subjects were three prostate patients with bilateral hip prosthesis who had undergone radical radiotherapy. The treatment plans were five-field three-dimensional conformal radiation therapy (3D-CRT), fixed 5-field intensity-modulated radiation therapy (IMRT) using similar gantry angles, and single-arc volumetric modulated arc therapy (VMAT). The monitor units (MUs), dose volume histograms (DVHs), the dose indices of planning target volume (PTV), clinical target volume (CTV) and rectum were compared among the three techniques. The geometrical uncertainties were evaluated by shifting the iso-center (2- 10 mm in the anterior, posterior, left, right, superior, and inferior directions). The CTV and rectum dose indexes with and without the iso-center shifts were compared in each plan. RESULTS The Conformity Index of PTV were 1.35 in 3D-CRT, 1.12 in IMRT, and 1.04 in VMAT, respectively. The rectum doses in 3D-CRT are also higher than those in IMRT and VMAT. The iso-center shift little affected the CTV dose when smaller than the margin size. The rectum dose increased especially after a posterior shift. Additionally, this dose increase was larger in the VMAT plan than in the 3D- CRT plan. However, the VMAT achieved a superior rectum DVH to that of 3D- CRT, and this effect clearly exceeded the rectum-dose increase elicited by the iso-center shift. CONCLUSION For radiotherapy treatment of localized prostate cancer in patients with hip prosthesis, the dose distribution was better in the VMAT and Metal Artifact Reduction (MAR)-CT image methods than the conventional methods. Because the anatomical structure of the male pelvic region is relatively constant among individuals, we consider that VMAT is a valid treatment plan despite analyzing just three cases.
Collapse
Affiliation(s)
- Rikana Soda
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Shogo Hatanaka
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Masatsugu Hariu
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Munefumi Shimbo
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Takafumi Yamano
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Keiichiro Nishimura
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Shuichi Kondo
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| | - Nobuko Utsumi
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
- Department of Radiology, JCHO Tokyo Shinjuku Medical Center, Tsukudocho, Shinjuku-Ku, Tokyo, Japan
| | - Takeo Takahashi
- Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kamoda, Kawagoe City, Saitama, Japan
| |
Collapse
|
21
|
Koike Y, Ohira S, Akino Y, Sagawa T, Yagi M, Ueda Y, Miyazaki M, Sumida I, Teshima T, Ogawa K. Deep learning‐based virtual noncontrast CT for volumetric modulated arc therapy planning: Comparison with a dual‐energy CT‐based approach. Med Phys 2019; 47:371-379. [DOI: 10.1002/mp.13925] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 11/11/2019] [Accepted: 11/11/2019] [Indexed: 12/12/2022] Open
Affiliation(s)
- Yuhei Koike
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Shingo Ohira
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Yuichi Akino
- Oncology center Osaka University Hospital Suita 565‐0871Japan
| | - Tomohiro Sagawa
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Masashi Yagi
- Department of Carbon Ion Radiotherapy Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Iori Sumida
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Teruki Teshima
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| |
Collapse
|
22
|
Kim ST, An HJ, Kim JI, Yoo JR, Kim HJ, Park JM. Non-coplanar VMAT plans for lung SABR to reduce dose to the heart: a planning study. Br J Radiol 2019; 93:20190596. [PMID: 31625759 DOI: 10.1259/bjr.20190596] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVE This study aimed to compare the plan quality of non-coplanar partial arc (NPA) volumetric modulated arc therapy (VMAT) to that of coplanar partial arc (CPA) VMAT for stereotactic ablative radiotherapy (SABR) for lung cancer. METHODS A total of 20 patients treated for lung cancer with the SABR VMAT technique and whose lung tumors were close to the heart were retrospectively selected for this study. For the CPA VMAT, three coplanar half arcs were used while two coplanar half arcs and one noncoplanar arc rotating 315°-45° with couch rotations of 315° ± 5° were used for the NPA VMAT. For each patient, identical CT image sets and identical structures were used for both the CPA and NPA VMAT plans. Dose-volumetric parameters of each plan were analyzed. RESULTS For the planning target volume and both lungs, no statistically significant differences between the CPA and NPA VMAT plans were observed in general. For the heart, average values of D0.1cc of the CPA and NPA VMAT plans were 29.42 ± 13.37 and 21.71 ± 9.20 Gy, respectively (p < 0.001). For whole body, the mean dose and the gradient index of the CPA VMAT plans were 1.2 ± 0.5 Gy and 4.356 ± 0.608 while those of the NPA VMAT plans were 1.1 ± 0.5 Gy and 4.111 ± 0.480, respectively (both with p < 0.001). CONCLUSION The NPA VMAT proposed in this study showed more favorable plan quality than the CPA VMAT plans for lung SABR with tumors located close to the heart. ADVANCES IN KNOWLEDGE For lung SABR, NPA VMAT can reduce doses to the heart as well as whole-body irradiation.
Collapse
Affiliation(s)
- Sang-Tae Kim
- Nuclear Emergency Division, Radiation Protection and Emergency Preparedness Bureau, Nuclear Safety and Security Commission, Seoul, Korea
| | - Hyun Joon An
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea.,Department of Biomedical Sciences, Seoul National University, Seoul, Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Jae-Ryong Yoo
- Radiation Emergency Medicine Regulation Team, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea
| | - Hak Jae Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea.,Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea.,Robotics Research Laboratory for Extreme Environments, Advanced Institute of Convergence Technology, Suwon, Korea
| |
Collapse
|
23
|
Palmer JD, Sebastian NT, Chu J, DiCostanzo D, Bell EH, Grecula J, Arnett A, Blakaj DM, McGregor J, Elder JB, Lu L, Zoller W, Addington M, Lonser R, Chakravarti A, Brown PD, Raval R. Single-Isocenter Multitarget Stereotactic Radiosurgery Is Safe and Effective in the Treatment of Multiple Brain Metastases. Adv Radiat Oncol 2019; 5:70-76. [PMID: 32051892 PMCID: PMC7004936 DOI: 10.1016/j.adro.2019.08.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 08/14/2019] [Accepted: 08/22/2019] [Indexed: 12/20/2022] Open
Abstract
Purpose Multiple studies have reported favorable outcomes for stereotactic radiosurgery (SRS) in the treatment of limited brain metastases. An obstacle of SRS in the management of numerous metastases is the longer treatment time using traditional radiosurgery. Single-isocenter multitarget (SIMT) SRS is a novel technique that permits rapid therapy delivery to multiple metastases. There is a lack of clinical evidence regarding its efficacy and safety. We report the outcomes of patients treated with this technique. Methods and Materials We reviewed the records of patients with intact or resected brain metastases treated with SRS in 1 to 5 fractions using SIMT technique at our institution, with at least 1 available follow-up brain magnetic resonance imaging. Survival, disease control, and toxicity were evaluated using Cox regression, logistic regression, and Kaplan-Meier analysis. Results We identified 173 patients with 1014 brain metastases. Median follow up was 12.7 months. Median beam-on time was 4.1 minutes. The median dose to the brain was 219.4 cGy. Median overall survival and freedom from intracranial progression were 13.2 and 6.3 months, respectively. Overall survival did not differ between patients treated with greater than or less than 4 lesions (hazard ratio, 1.03; 95% confidence interval 0.66-1.61; P = .91). Actuarial 1- and 2-year local control were 99.0% and 95.1%, respectively. Rates of grade 2 and grade 3 or higher radionecrosis were 1.4% and 0.9%, respectively. Conclusions SIMT radiosurgery delivered in 1 to 5 fractions offers excellent local control and acceptable toxicity in the treatment of multiple intact and postoperative brain metastases. This technique should be evaluated prospectively.
Collapse
Affiliation(s)
- Joshua D Palmer
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio.,Department of Neurosurgery, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus, Ohio
| | - Nikhil T Sebastian
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Jacquline Chu
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Dominic DiCostanzo
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Erica H Bell
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - John Grecula
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Andrea Arnett
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Dukagjin M Blakaj
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - John McGregor
- Department of Neurosurgery, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus, Ohio
| | - James B Elder
- Department of Neurosurgery, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus, Ohio
| | - Lanchun Lu
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Wesley Zoller
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Mark Addington
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Russell Lonser
- Department of Neurosurgery, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus, Ohio
| | - Arnab Chakravarti
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| | - Paul D Brown
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota
| | - Raju Raval
- Department of Radiation Oncology, The Ohio State University Comprehensive Cancer Center, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, Columbus Ohio
| |
Collapse
|
24
|
Dose verification of volumetric-modulated arc therapy using one-dimensional and two-dimensional dosimeters. JOURNAL OF RADIOTHERAPY IN PRACTICE 2019. [DOI: 10.1017/s1460396918000559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractPurposeTo verify dose delivery and quality assurance of volumetric-modulated arc therapy (VMAT) for head and neck (H&N) cancer.MethodThe Imaging and Radiation Oncology Core Houston (IROC-H) H&N phantom with thermoluminescent dosimeters (TLDs) and films, were imaged with computed tomography scan and the reconstructed image was transferred to pinnacle treatment planning system (TPS). On TPS, the planning target volume (PTV), secondary target volume (STV) and organ at risk (OAR) were delineated manually and a treatment plan was made. The dose constraints were determined for the concerned organs according to IROC-H prescription. The treatment plan was optimised using adoptive convolution algorithm to improve dose homogeneity and conformity. The dose calculation was performed using C.C Convolution algorithm and a Varian True Beam linear accelerator was used to deliver the treatment plan to the H&N phantom. The delivered radiation dose to the phantom was measured through TLDs and GafChromic external beam radiotherapy 2 (EBT2) films. The dosimetric performance of the VMAT delivery was studied by analysing percent dose difference, isodose line profile and gamma analysis of the TPS-computed dose and linac-delivered doses.ResultThe percent dose difference of 3.8% was observed between the planned and measured doses of TLDs and a 1.5-mm distance to agreement (DTA) was observed by comparing isodose line profiles. Passed the gamma criteria of 3%/3 mm was with good percentages.ConclusionThe dosimetric performance of VMAT delivery for a challenging H&N radiotherapy can be verified using TLDs and films embedded in an anthropomorphic H&N phantom.
Collapse
|
25
|
Choi CH, Kim JH, Kim JI, Park JM. Comparison of treatment plan quality among MRI-based IMRT with a linac, MRI-based IMRT with tri-Co-60 sources, and VMAT for spine SABR. PLoS One 2019; 14:e0220039. [PMID: 31329641 PMCID: PMC6645671 DOI: 10.1371/journal.pone.0220039] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Accepted: 07/08/2019] [Indexed: 11/18/2022] Open
Abstract
PURPOSE This study compares the plan quality of magnetic-resonance image (MRI)-based intensity modulated radiation therapy (IMRT) using a linac (MR-linac-IMRT), MRI-based IMRT using tri-Co-60 sources (MR-Co-60-IMRT), and volumetric modulated arc therapy (VMAT) for spine stereotactic ablative radiotherapy (SABR). METHODS Twenty patients with thoracic spine metastasis were retrospectively selected for this study. For each patient, the MR-linac-IMRT, MR-Co-60-IMRT, and VMAT plans were generated using an identical CT image set and structures, except for the spinal cord and spinal cord planning organ-at-risk volume (PRV). Those two structures were contoured based on CT image sets for VMAT planning while those were contoured based on MR image sets for MR-linac-IMRT and MR-Co-60-IMRT planning. The initial prescription doses were 18 Gy in a single fraction for every plan in this study. If the tolerance level of the spinal cord was not met, the prescription doses were reduced to meet the tolerance level of the spinal cord. Dose-volumetric parameters of each plan were analyzed. RESULTS The average spinal cord volumes contoured based on the CT and MR images were 3.8±1.6 cm3 and 1.1±1.0 cm3, respectively (p<0.001). For four patients, the prescription doses of VMAT plans were reduced to 16 Gy to satisfy the spinal cord tolerance level. For thirteen patients, the prescription doses of MR-Co-60-IMRT plans were reduced to be less than 16 Gy to meet the spinal cord tolerance level. However, for every MR-linac-IMRT plan, the initial prescription doses of 18 Gy could be delivered to the target volume while satisfying the spinal cord tolerance. The average values of D10%, V10Gy, and V14Gy of the spinal cord PRV consistently indicated that the doses to the spinal cord PRV in the MR-linac-IMRT plans were the lowest among three types of plans in this study (all with p≤0.003). CONCLUSION MR-linac-IMRT appears promising for spine SABR.
Collapse
Affiliation(s)
- Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Radiation Oncology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah, United Arab Emirates
| | - Jin Ho Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Jung-in Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
- * E-mail: (JMP); (JK)
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
- Robotics Research Laboratory for Extreme Environments, Advanced Institute of Convergence Technology, Suwon, Korea
- * E-mail: (JMP); (JK)
| |
Collapse
|
26
|
Hatano K, Tohyama N, Kodama T, Okabe N, Sakai M, Konoeda K. Current status of intensity‐modulated radiation therapy for prostate cancer: History, clinical results and future directions. Int J Urol 2019; 26:775-784. [DOI: 10.1111/iju.14011] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 04/07/2019] [Indexed: 01/05/2023]
Affiliation(s)
- Kazuo Hatano
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| | - Naoki Tohyama
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| | - Takashi Kodama
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| | - Naoyuki Okabe
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| | - Mitsuhiro Sakai
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| | - Koichi Konoeda
- Division of Radiation Oncology Tokyo‐Bay Advanced Imaging & Radiation Oncology Clinic/Makuhari Chiba Japan
| |
Collapse
|
27
|
Chun M, Joon An H, Kwon O, Oh DH, Park JM, Kim JI. Impact of plan parameters and modulation indices on patient-specific QA results for standard and stereotactic VMAT. Phys Med 2019; 62:83-94. [PMID: 31153402 DOI: 10.1016/j.ejmp.2019.05.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 05/03/2019] [Accepted: 05/04/2019] [Indexed: 12/30/2022] Open
Abstract
PURPOSE To demonstrate the impact of modulation indices and plan parameters on the gamma passing rates (GPR) of patient-specific quality assurance of standard and stereotactic volumetric modulated arc therapy (VMAT) plans. METHODS A total of 758 patients' QA plans were utilized, including standard VMAT plans with Trilogy (n = 87, group A) and TreuBeam STx (n = 332, group B), and 339 stereotactic VMAT plans with TrueBeam STx (group C). Modulation indices were obtained considering the speed and acceleration of the multileaf collimator (MLC) (MIs, MIa), and MLC, gantry speed, and dose rate changes (MIt). The mean aperture size (MA), monitor unit (MU), and amount of jaw tracking (%JT) were acquired. Gamma analysis was performed with 2 mm/2% and 1 mm/2% for the standard and stereotactic VMAT plans, respectively. Statistical analyses were performed to investigate the correlation between modulation index/plan parameters and GPR. RESULTS Spearman's rank correlation to GPRs with MIs, MIa, and MIt, were -0.44, -0.45, and -0.46 for group A; -0.39, -0.37, and -0.38 for group B; and -0.04, -0.11, and -0.10 for group C, respectively. While MU and MA showed significant correlations in all groups, %JT showed a significant correlation only with stereotactic VMAT plans. The most influential parameter combinations were MU-MA (rs = 0.50), MIs-%JT (rs = 0.43), and MU-%JT (rs = 0.38) for groups A, B, and C, respectively. CONCLUSIONS MLC modulation mostly affected the GPR in the delivery of standard VMAT plans, while MU and %JT showed more importance in stereotactic VMAT plans.
Collapse
Affiliation(s)
- Minsoo Chun
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Hyun Joon An
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Ohyun Kwon
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Do Hoon Oh
- Department of Radiation Oncology, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea; Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
| |
Collapse
|
28
|
Hoffmann M, Pacey J, Goodworth J, Laszcyzk A, Ford R, Chick B, Greenham S, Westhuyzen J. Analysis of a volumetric-modulated arc therapy (VMAT) single phase prostate template as a class solution. Rep Pract Oncol Radiother 2018; 24:92-96. [PMID: 30505239 DOI: 10.1016/j.rpor.2018.10.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 09/26/2018] [Accepted: 10/28/2018] [Indexed: 12/31/2022] Open
Abstract
Aim To assess a class solution template for volumetric-modulated arc therapy (VMAT) for prostate cancer using plan analysis software. Background VMAT is a development of intensity-modulated radiotherapy (IMRT) with potential advantages for the delivery of radiotherapy (RT) in prostate cancer. Class solutions are increasingly used for facilitating RT planning. Plan analysis software provides an objective tool for evaluating class solutions. Materials and methods The class solution for VMAT was based on the current static field IMRT template. The plans of 77 prostate cancer patients were evaluated using a set of in-house plan quality metrics (scores) (PlanIQ™, Sun Nuclear Corporation). The metrics compared the class solution for VMAT planning with the IMRT template and the delivered clinical plan (CP). Eight metrics were associated with target coverage and ten with organs-at-risk (OAR). Individual metrics were summed and the combined scores were subjected to non-parametric analysis. The low-dose wash for both static IMRT and VMAT plans were evaluated using 40 Gy and 25 Gy isodose volumes. Results VMAT plans were of equal or better quality than the IMRT template and CP for target coverage (combined score) and OAR combined score. The 40 Gy isodose volume was marginally higher with VMAT than IMRT (4.9%) but lower than CP (-6.6%)(P = 0.0074). The 25 Gy volume was significantly lower with VMAT than both IMRT (-32.7%) and CP (-34.4%)(P < 0.00001). Conclusions Automated VMAT planning for prostate cancer is feasible and the plans are equal to or better than the current IMRT class solution and the delivered clinical plan.
Collapse
Affiliation(s)
- Matthew Hoffmann
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales, Australia
| | - Jacqueline Pacey
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Josie Goodworth
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Andrea Laszcyzk
- Department of Radiation Oncology, Northern New South Wales Cancer Institute, Lismore, New South Wales, Australia
| | - Richard Ford
- Department of Radiation Oncology, Northern New South Wales Cancer Institute, Lismore, New South Wales, Australia
| | - Brendon Chick
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Port Macquarie, New South Wales, Australia
| | - Stuart Greenham
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| | - Justin Westhuyzen
- Department of Radiation Oncology, Mid-North Coast Cancer Institute, Coffs Harbour, New South Wales, Australia
| |
Collapse
|
29
|
Park JM, Kim JI, Park SY, Oh DH, Kim ST. Reliability of the gamma index analysis as a verification method of volumetric modulated arc therapy plans. Radiat Oncol 2018; 13:175. [PMID: 30217163 PMCID: PMC6137931 DOI: 10.1186/s13014-018-1123-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 08/31/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND We investigate the gamma passing rate (GPR) consistency when applying different types of gamma analyses, linacs, and dosimeters for volumetric modulated arc therapy (VMAT). METHODS A total of 240 VMAT plans for various treatment sites, which were generated with Trilogy (140 plans) and TrueBeam STx (100 plans), were retrospectively selected. For each VMAT plan, planar dose distributions were measured with both MapCHECK2 and ArcCHECK dosimeters. During the planar dose distribution measurements, the actual multileaf collimator (MLC) positions, gantry angles, and delivered monitor units were recorded and compared to the values in the original VMAT plans to calculate mechanical errors. For each VMAT plan, both the global and local gamma analyses were performed with 3%/3 mm, 2%/2 mm, 2%/1 mm, 1%/2 mm, and 1%/1 mm. The Pearson correlation coefficients (r) were calculated 1) between the global and the local GPRs, 2) between GPRs with the MapCHECK2 and the ArcCHECK dosimeters, 3) and between GPRs and the mechanical errors during the VMAT delivery. RESULTS For the MapCHECK2 measurements, strong correlations between the global and local GPRs were observed only with 1%/2 mm and 1%/1 mm (r > 0.8 with p < 0.001), while weak or no correlations were observed for the ArcCHECK measurement. Between the MapCHECK2 and ArcCHECK measurements, the global GPRs showed no correlations (all with p > 0.05), while the local GPRs showed moderate correlations only with 2%/1 mm and 1%/1 mm for TrueBeam STx (r > 0.5 with p < 0.001). Both the global and local GPRs always showed weak or no correlations with the MLC positional errors except for the GPRs of MapCHECK2 with 1%/2 mm and 1%/1 mm for TrueBeam STx and the GPR of ArcCHECK with 1%/2 mm for Trilogy (r < - 0.5 with p < 0.001). CONCLUSIONS The GPRs varied according to the types of gamma analyses, dosimeters, and linacs. Therefore, each institution should carefully establish their own gamma analysis protocol by determining the type of gamma index analysis and the gamma criterion with their own linac and their own dosimeter.
Collapse
Affiliation(s)
- Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, South Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, South Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, South Korea.,Institute for Smart System, Robotics Research Laboratory for Extreme Environments, Advanced Institutes of Convergence Technology, Suwon, South Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, South Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, South Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, South Korea
| | - So-Yeon Park
- Department of Radiation Oncology, Veterans Health Service Medical Center, Seoul, South Korea
| | - Do Hoon Oh
- Department of Radiation Oncology, Myongji Hospital, Goyang, South Korea.
| | - Sang-Tae Kim
- Nuclear Emergency Division, Radiation Protection and Emergency Preparedness Bureau, Nuclear Safety and Security Commission, Seoul, South Korea.
| |
Collapse
|
30
|
Gurdal N, Fayda M, Alishev N, Bakir B, Tastekin D, Aykan F, Gezer U, Balik E, Saglam EK, Oral EN, Gulluoglu M, Kizir A. Neoadjuvant volumetric modulated arc therapy in rectal cancer and the correlation of pathological response with diffusion-weighted MRI and apoptotic markers. TUMORI JOURNAL 2018; 104:266-272. [PMID: 29218690 DOI: 10.5301/tj.5000702] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE In this prospective observational study, we aimed to report the applicability and tolerability of neoadjuvant volumetric modulated arc therapy with simultaneous integrated boost (SIB-VMAT) and concurrent chemotherapy in patients with locally advanced rectal cancer (LARC), and to evaluate the correlation of pathological response with apparent diffusion coefficient (ADC) measurements on diffusion-weighted magnetic resonance imaging (DW-MRI) and apoptotic markers. METHODS The study enrolled 30 patients with T3 to T4 and/or N+ rectal cancer who preoperatively received SIB-VMAT and concurrent chemotherapy. Before and after the neoadjuvant treatment, apoptotic markers including the nucleosomes and cell-free DNA fragments in the serum samples were examined; DNA integrity was assessed by amplifying the ACTB gene; and the ADC measurements on the DW-MRI were analyzed. RESULTS No patients had acute or chronic grade III-IV toxicity. Pathologic complete response (pCR) was achieved in 8 patients (27%), while in 10 patients (33%) near-complete pathological response was obtained. Posttreatment ADC was significantly higher in patients with pCR compared with the others (1.28 vs. 1.10, p = 0.017). ROC curve analysis showed that posttreatment ADC values had a sensitivity of 75% and a specificity of 77.3% for distinguishing the patients with pCR from other responders. On the other hand, posttreatment DNA integrity values were revealed lower than the pretreatment values (p = 0.36). Also, the results revealed an insignificant increase in the posttreatment serum level of nucleosomes (p = 0.72). CONCLUSIONS Neoadjuvant SIB-VMAT with concurrent chemotherapy was proved to be a feasible treatment regimen in LARC with tolerable side effects, and improved local control rate and pCR rate.
Collapse
Affiliation(s)
- Necla Gurdal
- 1 Department of Radiation Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Merdan Fayda
- 2 Department of Radiation Oncology, Istinye University, Faculty of Medicine, Istanbul - Turkey
| | - Nijat Alishev
- 3 Department of Radiology, Istanbul University, Istanbul Faculty of Medicine, Istanbul - Turkey
| | - Baris Bakir
- 3 Department of Radiology, Istanbul University, Istanbul Faculty of Medicine, Istanbul - Turkey
| | - Didem Tastekin
- 4 Department of Medical Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Faruk Aykan
- 4 Department of Medical Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Ugur Gezer
- 5 Department of Basic Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Emre Balik
- 6 Department of General Surgery, Istanbul University, Istanbul Faculty of Medicine, Istanbul - Turkey
| | - Esra Kaytan Saglam
- 1 Department of Radiation Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Ethem Nezih Oral
- 1 Department of Radiation Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| | - Mine Gulluoglu
- 7 Deparment of Pathology, Istanbul University, Istanbul Faculty of Medicine, Istanbul - Turkey
| | - Ahmet Kizir
- 1 Department of Radiation Oncology, Institute of Oncology, Istanbul University, Istanbul - Turkey
| |
Collapse
|
31
|
Sánchez-Nieto B, Romero-Expósito M, Terrón JA, Irazola L, Paiusco M, Cagni E, Ghetti C, Filice S, Sánchez-Doblado F. Intensity-modulated radiation therapy and volumetric modulated arc therapy versus conventional conformal techniques at high energy: Dose assessment and impact on second primary cancer in the out-of-field region. Rep Pract Oncol Radiother 2018; 23:251-259. [PMID: 29991929 PMCID: PMC6035902 DOI: 10.1016/j.rpor.2018.04.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Revised: 01/19/2018] [Accepted: 04/12/2018] [Indexed: 12/22/2022] Open
Abstract
The aim of this work was to estimate peripheral neutron and photon doses associated with the conventional 3D conformal radiotherapy techniques in comparison to modern ones such as Intensity modulated radiation therapy and volumetric modulated arc therapy. Assessment in terms of second cancer incidence ought to peripheral doses was also considered. For that, a dosimetric methodology proposed by the authors has been applied beyond the region where there is no CT information and, thus, treatment planning systems do not calculate and where, nonetheless, about one third of second primary cancers occurs.
Collapse
Affiliation(s)
- Beatriz Sánchez-Nieto
- Instituto de Física, Pontificia Universidad Católica de Chile, Santiago, Chile
- Center UC Investigation in Oncology at Pontificia Universidad Católica de Chile, Pontificia Universidad Católica de Chile, Santiago, Chile
| | | | - José Antonio Terrón
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - Leticia Irazola
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla, Spain
| | - Marta Paiusco
- Veneto Institute of Oncology IOV – IRCCS, Padua, Italy
| | | | - Caterina Ghetti
- Servizio di Fisica Sanitaria, Azienda Ospedaliera Universitaria di Parma, Italy
| | - Silvano Filice
- Servizio di Fisica Sanitaria, Azienda Ospedaliera Universitaria di Parma, Italy
| | - Francisco Sánchez-Doblado
- Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla, Spain
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla, Spain
| |
Collapse
|
32
|
Effect of translational couch shifts in volumetric modulated arc therapy (VMAT) plans and predicting its impact on daily dose delivery. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s146039691700053x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractAimTo evaluate the impact of couch translational shifts on dose–volume histogram (DVH) and radiobiological parameters [tumour control probability (TCP), equivalent uniform dose (EUD) and normal tissue complication probability (NTCP)] of volumetric modulated arc therapy (VMAT) plans and to develop a simple and swift method to predict the same online, on a daily basis.MethodsIn total, ten prostate patients treated with VMAT technology were selected for this study. The plans were generated using Eclipse TPS and delivered using Clinac ix LINAC equipped with a Millennium 120 multileaf collimator. In order to find the effect of systematic translational couch shifts on the DVH and radiobiological parameters, errors were introduced in the clinically accepted base plan with an increment of 1 mm and up to 5 mm from the iso-centre in both positive and negative directions of each of the three axis, x [right–left (R-L)], y [superior–inferior (S-I)] and z [anterior–posterior (A-P)]. The percentages of difference in these parameters (∆D, ∆TCP, ∆EUD and ∆NTCP) were analyzed between the base plan and the error introduced plans. DVHs of the base plan and the error plans were imported into the MATLAB software (R2013a) and an in-house MATLAB code was generated to find the best curve fitted polynomial functions for each point on the DVH, there by generating predicted DVH for planning target volume (PTV), clinical target volume (CTV) and organs at risks (OARs). Functions f(x, vj), f(y, vj) and f(z, vj) were found to represent the variation in the dose when there are couch translation shifts in R-L, S-I and A-P directions, respectively. The validation of this method was done by introducing daily couch shifts and comparing the treatment planning system (TPS) generated DVHs and radiobiological parameters with MATLAB code predicted parameters.ResultsIt was noted that the variations in the dose to the CTV, due to both systematic and random shifts, were very small. For CTV and PTV, the maximum variations in both DVH and radiobiological parameters were observed in the S-I direction than in the A-P or R-L directions. ∆V70 Gy and ∆V60 Gy of the bladder varied more due to S-I shift whereas, ∆V40 Gy, ∆EUD and ∆NTCP varied due to A-P shifts. All the parameters in rectum were most affected by the A-P shifts than the shifts in other two directions. The maximum percentage of deviation between the TPS calculated and MATLAB predicted DVHs of plans were calculated for targets and OARs and were found to be less than 0·5%.ConclusionThe variations in the parameters depend upon the direction and magnitude of the shift. The DVH curves generated by the TPS and predicted by the MATLAB showed good correlation.
Collapse
|
33
|
Ippolito E, Guido A, Macchia G, Deodato F, Giaccherini L, Farioli A, Arcelli A, Cuicchi D, Frazzoni L, Cilla S, Buwenge M, Mantini G, Alitto AR, Nuzzo M, Valentini V, Ingrosso M, Morganti AG, Fuccio L. Predictive Factors of Late-onset Rectal Mucosal Changes After Radiotherapy of Prostate Cancer. ACTA ACUST UNITED AC 2018; 31:961-966. [PMID: 28882966 DOI: 10.21873/invivo.11154] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 07/03/2017] [Accepted: 07/06/2017] [Indexed: 12/19/2022]
Abstract
BACKGROUND/AIM The Vienna Rectoscopy Score (VRS; from 0, absence of rectal mucosal changes, to 5) assessed 1 year after radiotherapy is a surrogate end-point of late rectal toxicity. The aim of this study was to investigate the association between treatment-related factors and 1-year VRS. PATIENTS AND METHODS We performed a retrospective analysis of prospectively collected data. Patients with prostate adenocarcinoma treated with definitive or postoperative radiotherapy (RT) underwent endoscopy 1 year after RT. Relationships between VRS of 2 or more and treatment parameters were investigated by univariate and multivariate logistic analyses. RESULTS One hundred and ninety-five patients (mean age=69 years; range=43-81 years) were considered eligible for the study. At univariate analysis, patients treated with hypofractionation plus radiosurgery boost (p<0.001) and an equivalent dose in 2 Gy per fraction (EQD2) (α/β=3) ≥75 Gy (p<0.001) was associated with a significantly higher incidence of VRS ≥2 after 1 year of follow-up. At multivariate analysis, radiosurgery boost was an independent risk factor for developing rectal mucosal lesions (VRS ≥2), yielding an odds ratio (OR) of 4.14 (95% confidence interval (CI)=1.2-13.8), while pelvic surgery was inversely associated with VRS ≥2 (OR=0.39; 95% CI=0.17-0.94). CONCLUSION Hypofractionation followed by radiosurgery boost significantly increased the risk of developing late-onset rectal mucosal changes. Therefore, special care and preventative treatment strategies are needed when using radiosurgery boost after hypofractionated RT.
Collapse
Affiliation(s)
- Edy Ippolito
- Radiotherapy Unit, Campus Bio-Medico University, Rome, Italy
| | - Alessandra Guido
- Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine DIMES, University of Bologna, Bologna, Italy
| | - Gabriella Macchia
- Radiotherapy Unit, Giovanni Paolo II Research and Care Foundation, Campobasso, Italy
| | - Francesco Deodato
- Radiotherapy Unit, Giovanni Paolo II Research and Care Foundation, Campobasso, Italy
| | - Lucia Giaccherini
- Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine DIMES, University of Bologna, Bologna, Italy
| | - Andrea Farioli
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Alessandra Arcelli
- Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine DIMES, University of Bologna, Bologna, Italy
| | - Dajana Cuicchi
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Leonardo Frazzoni
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Savino Cilla
- Medical Physics Unit, Giovanni Paolo II Research and Care Foundation, Campobasso, Italy
| | - Milly Buwenge
- Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine DIMES, University of Bologna, Bologna, Italy
| | - Giovanna Mantini
- Department of Radiotherapy, A. Gemelli Hospital, Sacred Heart Catholic University, Rome, Italy
| | - Anna R Alitto
- Department of Radiotherapy, A. Gemelli Hospital, Sacred Heart Catholic University, Rome, Italy
| | - Marianna Nuzzo
- Radiotherapy Unit, Giovanni Paolo II Research and Care Foundation, Campobasso, Italy
| | - Vincenzo Valentini
- Department of Radiotherapy, A. Gemelli Hospital, Sacred Heart Catholic University, Rome, Italy
| | - Marcello Ingrosso
- Endoscopy Unit, Giovanni Paolo II Research and Care Foundation, Campobasso, Italy
| | - Alessio G Morganti
- Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine DIMES, University of Bologna, Bologna, Italy
| | - Lorenzo Fuccio
- Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| |
Collapse
|
34
|
Hirashima H, Miyabe Y, Nakamura M, Mukumoto N, Mizowaki T, Hiraoka M. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation. J Appl Clin Med Phys 2018; 19:234-242. [PMID: 29633542 PMCID: PMC5978977 DOI: 10.1002/acm2.12324] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 12/28/2017] [Accepted: 03/02/2018] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to develop a simple verification method for the routine quality assurance (QA) of Dynamic WaveArc (DWA) irradiation using electronic portal imaging device (EPID) images and log data analysis. First, an automatic calibration method utilizing the outermost multileaf collimator (MLC) slits was developed to correct the misalignment between the center of the EPID and the beam axis. Moreover, to verify the detection accuracy of the MLC position according to the EPID images, various positions of the MLC with intentional errors in the range 0.1–1 mm were assessed. Second, to validate the geometric accuracy during DWA irradiation, tests were designed in consideration of three indices. Test 1 evaluated the accuracy of the MLC position. Test 2 assessed dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.2–6°/s), and ring speed (0.5–2.7°/s). Test 3 validated dose output consistency with variable values of the above parameters plus MLC speed (1.6–4.2 cm/s). All tests were delivered to the EPID and compared with those obtained using a stationary radiation beam with a 0° gantry angle. Irradiation log data were recorded simultaneously. The 0.1‐mm intentional error on the MLC position could be detected by the EPID, which is smaller than the EPID pixel size. In Test 1, the MLC slit widths agreed within 0.20 mm of their exposed values. The averaged root‐mean‐square error (RMSE) of the dose outputs was less than 0.8% in Test 2 and Test 3. Using log data analysis in Test 3, the RMSE between the planned and recorded data was 0.1 mm, 0.12°, and 0.07° for the MLC position, gantry angle, and ring angle, respectively. The proposed method is useful for routine QA of the accuracy of DWA.
Collapse
Affiliation(s)
- Hideaki Hirashima
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Mitsuhiro Nakamura
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Nobutaka Mukumoto
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
35
|
Utilising the Virtual Environment for Radiotherapy Training System to Support Undergraduate Teaching of IMRT, VMAT, DCAT Treatment Planning, and QA Concepts. J Med Imaging Radiat Sci 2018; 49:31-38. [DOI: 10.1016/j.jmir.2017.11.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 11/17/2017] [Accepted: 11/20/2017] [Indexed: 11/22/2022]
|
36
|
Li MH, Huang SF, Chang CC, Lin JC, Tsai JT. Variations in dosimetric distribution and plan complexity with collimator angles in hypofractionated volumetric arc radiotherapy for treating prostate cancer. J Appl Clin Med Phys 2018; 19:93-102. [PMID: 29322625 PMCID: PMC5849828 DOI: 10.1002/acm2.12249] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 10/19/2017] [Accepted: 12/05/2017] [Indexed: 11/21/2022] Open
Abstract
Purpose Hypofractionated radiotherapy can reduce treatment durations and produce effects identical to those of conventionally fractionated radiotherapy for treating prostate cancer. Volumetric arc radiotherapy (VMAT) can decrease the treatment machine monitor units (MUs). Previous studies have shown that VMAT with multileaf collimator (MLC) rotation exhibits better target dose distribution. Thus, VMAT with MLC rotation warrants further investigation. Methods and materials Ten patients with prostate cancer were included in this study. The prostate gland and seminal vesicle received 68.75 and 55 Gy, respectively, in 25 fractions. A dual‐arc VMAT plan with a collimator angle of 0° was generated and the same constraints were used to reoptimize VMAT plans with different collimator angles. The conformity index (CI), homogeneity index (HI), gradient index (GI), normalized dose contrast (NDC), MU, and modulation complexity score (MCSV) of the target were analyzed. The dose–volume histogram of the adjacent organs was analyzed. A Wilcoxon signed‐rank test was used to compare different collimator angles. Results Optimum values of CI, HI, and MCSV were obtained with a collimator angle of 45°. The optimum values of GI, and NDC were observed with a collimator angle of 0°. In the rectum, the highest values of maximum dose and volume receiving 60 Gy (V60 Gy) were obtained with a collimator angle of 0°, and the lowest value of mean dose (Dmean) was obtained with a collimator angle of 45°. In the bladder, high values of Dmean were obtained with collimator angles of 75° and 90°. In the rectum and bladder, the values of V60 Gy obtained with the other tested angles were not significantly higher than those obtained with an angle of 0°. Conclusion This study found that MLC rotation affects VMAT plan complexity and dosimetric distribution. A collimator angle of 45° exhibited the optimal values of CI, HI, and MCSv among all the tested collimator angles. Late side effects of the rectum and bladder are associated with high‐dose volumes by previous studies. MLC rotation did not have statistically significantly higher values of V60 Gy in the rectum and bladder than did the 0° angle. We thought a collimator angle of 45° was an optimal angle for the prostate VMAT treatment plan. The findings can serve as a guide for collimator angle selection in prostate hypofractionated VMAT planning.
Collapse
Affiliation(s)
- Ming-Hsien Li
- Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, China
| | - Sheng-Fang Huang
- Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, China
| | - Chih-Chieh Chang
- Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, China
| | - Jang-Chun Lin
- Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, China.,School of Medicine, College of Medicine, Department of Radiology, Taipei Medical University, Taipei, Taiwan, China
| | - Jo-Ting Tsai
- Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, China.,School of Medicine, College of Medicine, Department of Radiology, Taipei Medical University, Taipei, Taiwan, China
| |
Collapse
|
37
|
De Ornelas-Couto M, Mihaylov I, Dogan N. Assessment of Volumetric-Modulated Arc Therapy for Constant and Variable Dose Rates. J Med Phys 2018; 42:199-205. [PMID: 29296033 PMCID: PMC5744447 DOI: 10.4103/jmp.jmp_65_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Purpose: The aim of this study is to compare the effects of dose rate on volumetric-modulated arc therapy plans to determine optimal dose rates for prostate and head and neck (HN) cases. Materials and Methods: Ten prostate and ten HN cases were retrospectively studied. For each case, seven plans were generated: one variable dose rate (VDR) and six constant dose rate (CDR) (100–600 monitor units [MUs]/min) plans. Prescription doses were: 80 Gy to planning target volume (PTV) for the prostate cases, and 70, 60, and 54 Gy to PTV1, PTV2, and PTV3, respectively, for HN cases. Plans were normalized to 95% of the PTV and PTV1, respectively, with the prescription dose. Plans were assessed using Dose-Volume-Histogram metrics, homogeneity index, conformity index, MUs, and delivery time. Results: For the prostate cases, significant differences were found for rectum D35 between VDR and all CDR plans, except CDR500. Furthermore, VDR was significantly different than CDR100 and 200 for bladder D50. Delivery time for all CDR plans and MUs for CDR400–600 were significantly higher when compared to VDR. HN cases showed significant differences between VDR and CDR100, 500 and 600 for D2 to the cord and brainstem. Significant differences were found for delivery time and MUs for all CDR plans, except CDR100 for number of MUs. Conclusion: The most significant differences were observed in delivery time and number of MUs. All-in-all, the best CDR for prostate cases was found to be 300 MUs/min and 200 or 300 MUs/min for HN cases. However, VDR plans are still the choice in terms of MU efficiency and plan quality.
Collapse
Affiliation(s)
| | - Ivaylo Mihaylov
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Nesrin Dogan
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
38
|
Li Y, Wang J, Tan L, Hui B, Ma X, Yan Y, Xue C, Shi X, Drokow EK, Ren J. Dosimetric comparison between IMRT and VMAT in irradiation for peripheral and central lung cancer. Oncol Lett 2018; 15:3735-3745. [PMID: 29467890 PMCID: PMC5795944 DOI: 10.3892/ol.2018.7732] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 11/30/2017] [Indexed: 12/12/2022] Open
Abstract
The aim of the present study was to compare intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in irradiation of lung cancer. Plans of 14 patients were compared. The results demonstrated that in peripheral lung cancer, V5 (%) of the lung in partial-arc (PA)-VMAT was decreased compared with IMRT, single-arc (SA)-, and double partial-arc (2PA)-VMAT. V30 (%) of the lung in IMRT was decreased compared with SA-, PA- and 2PA-VMAT. In the case of planning target volume (PTV) not encompassing the mediastinum in central lung cancer, the conformality index (CI) and heterogeneity index (HI) of SA-VMAT was improved compared with IMRT, PA-, and 2PA-VMAT. The received dose of heart in SA-VMAT was higher compared with IMRT, PA- and 2PA-VMAT. V30 (%) and V5 (%) of the lung in IMRT was higher compared with SA-, PA- and 2PA-VMAT; V10 (%) of the lung in 2PA was decreased compared with IMRT, SA- and PA. In the case of PTV encompassing the mediastinum in central lung cancer, the HI and CI of 2PA was improved compared with IMRT, SA- and PA-VMAT. The received dose of heart in 2PA was higher compared with IMRT, SA- and PA-VMAT. V30 (%) and V5 (%) of the lung in 2PA-VMAT was higher compared with IMRT, SA- and PA-VMAT. V20 (%) of the lung in 2PA was decreased compared with IMRT, SA- and PA-VMAT. In conclusion, it may be necessary to classify the radiotherapy plans of lung cancer into three categories including peripheral lung cancer, PTV not encompassing the mediastinum of central lung cancer, and PTV encompassing the mediastinum of central lung cancer. Each of IMRT, SA-VMAT, PA-VMAT, 2PA-VMAT strategy had individual advantages, and therefore it may be crucial to employ different planning techniques for different disease classifications and OAR requirements.
Collapse
Affiliation(s)
- Yi Li
- Department of Radiotherapy, Oncology Department, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Ji Wang
- Intensive Care Unit, China Meitan General Hospital, Beijing 100028, P.R. China
| | - Li Tan
- Medical School, Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Beina Hui
- Department of Radiotherapy, Oncology Department, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Xiaowei Ma
- Medical School, Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Yanli Yan
- Medical School, Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Chaofan Xue
- Medical School, Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Xiaoting Shi
- Department of Radiotherapy, Oncology Department, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Emmanuel Kwateng Drokow
- Department of Radiotherapy, Oncology Department, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| | - Juan Ren
- Department of Radiotherapy, Oncology Department, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China
| |
Collapse
|
39
|
Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans. JOURNAL OF RADIOTHERAPY IN PRACTICE 2017. [DOI: 10.1017/s1460396917000486] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractBackgroundElectronic portal imaging device (EPID) offers high-resolution digital image that can be compared with a predicted portal dose image. A very common method to quantitatively compare a measured and calculated dose distribution that is routinely used for quality assurance (QA) of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy treatment plans is the evaluation of the gamma index. The purpose of this work was to evaluate the gamma passing rate (%GP), maximum gamma (γmax), average gamma (γave), maximum dose difference (DDmax) and the average dose difference (DDave) for various regions of interest using Varian’s implementation of three absolute dose gamma calculation techniques of improved, local, and combined improved and local.Methods and materialsWe analyzed 232 portal dose images from 100 prostate cancer patients’ VMAT plans obtained using the Varian EPID on TrueBeam Linacs.ResultsOur data show that the %GP, γmax and γave depend on the gamma calculation method and the acceptance criteria. Higher %GP values were obtained compared with both our current institutional action level and the American Association of Physicists in Medicine Task Group 119 recommendations.ConclusionsThe results of this study can be used to establish stricter action levels for pre-treatment QA of prostate VMAT plans. A stricter 3%/3 mm improved gamma criterion with a passing rate of 97% or the 2%/2 mm improved gamma criterion with a passing rate of 95% can be achieved without additional measurements or configurations.
Collapse
|
40
|
Split-VMAT technique to control the expiratory breath-hold time in liver stereotactic body radiation therapy. Phys Med 2017; 40:17-23. [DOI: 10.1016/j.ejmp.2017.06.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 06/09/2017] [Accepted: 06/28/2017] [Indexed: 12/25/2022] Open
|
41
|
Kai Y, Toya R, Saito T, Kuraoka A, Shimohigashi Y, Nakaguchi Y, Maruyama M, Murakami R, Yamashita Y, Oya N. Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study. J Med Radiat Sci 2017; 65:39-47. [PMID: 28755441 PMCID: PMC5846018 DOI: 10.1002/jmrs.239] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 05/08/2017] [Accepted: 06/30/2017] [Indexed: 12/25/2022] Open
Abstract
Introduction Due to its spherical surface, scalp angiosarcoma requires careful consideration for radiation therapy planning and dose delivery. Herein, we investigated whether volumetric modulated arc therapy (VMAT) is superior to intensity modulated radiation therapy (IMRT) in terms of the plan quality and delivery time. Methods Three different coplanar treatment plans were created for four patients, comprising a two‐arc VMAT plan as well as 5‐field and 9‐field IMRT plans with 6 MV beams. The X‐ray Voxel Monte Carlo algorithm was employed for dose calculation. A radiation therapy dose of 60 Gy was prescribed to the planning target volume (PTV) in 30 fractions. The homogeneity indexes (HIs) and conformity indexes (CIs) of the PTV, organs at risk (OARs) doses and delivery times were calculated and compared. Results For the VMAT, 5‐field and 9‐field IMRT plans, the mean HIs were 0.14, 0.16 and 0.15; CIs100% were 0.63, 0.61 and 0.64; CIs98% were 0.72, 0.66 and 0.70 and CIs95% were 0.74, 0.67 and 0.71 respectively. All mean dose parameters of the VMAT and 9‐field IMRT plans for the brain were equal to or lower than those of the 5‐field IMRT plan. For the 5‐field IMRT plan, the dose constraints for the left lens were not satisfied in two patients. The mean delivery times were 3.3, 11.1 and 14.7 min for the VMAT, 5‐field and 9‐field IMRT plans respectively. Conclusion The VMAT plan quality is comparable to that of 9‐field IMRT, with a reduced delivery time. Therefore, VMAT represents a valuable, sophisticated irradiation technique for treating scalp angiosarcoma.
Collapse
Affiliation(s)
- Yudai Kai
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Ryo Toya
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan.,Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Tetsuo Saito
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan
| | - Akiko Kuraoka
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | | | - Yuji Nakaguchi
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Masato Maruyama
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Ryuji Murakami
- Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Kumamoto University Hospital, Kumamoto, Japan
| | - Natsuo Oya
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan
| |
Collapse
|
42
|
Macchia G, Deodato F, Cilla S, Cammelli S, Guido A, Ferioli M, Siepe G, Valentini V, Morganti AG, Ferrandina G. Volumetric modulated arc therapy for treatment of solid tumors: current insights. Onco Targets Ther 2017; 10:3755-3772. [PMID: 28794640 PMCID: PMC5538686 DOI: 10.2147/ott.s113119] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Aim This article discusses the current use of volumetric modulated arc therapy (VMAT) techniques in clinical practice and reviews the available data from clinical outcome studies in different clinical settings. An overview of available literature about clinical outcomes with VMAT stereotactic/radiosurgical treatment is also reported. Materials and methods All published manuscripts reporting the use of VMAT in a clinical setting from 2009 to November 2016 were identified. The search was carried out in December 2016 using the National Library of Medicine (PubMed/Medline). The following words were searched: “volumetric arc therapy”[All Fields] OR “vmat”[All Fields] OR “rapidarc”[All Fields], AND “radiotherapy”[All Fields] AND “Clinical Trial”[All Fields]. Results Overall, 37 studies (21 prospective and 16 retrospective) fulfilling inclusion criteria and thus included in the review evaluated 2,029 patients treated with VMAT; of these patients, ~30.8% had genitourinary (GU) tumors (81% prostate, 19% endometrial), 26.2% head-and-neck cancer (H&NC), 13.9% oligometastases, 11.2% had anorectal cancer, 10.6% thoracic neoplasms (81% breast, 19% lung), and 7.0% brain metastases (BMs). Six different clinical scenarios for VMAT use were identified: 1) BMs, 2) H&NC, 3) thoracic neoplasms, 4) GU cancer, 5) anorectal tumor, and 6) stereotactic body radiation therapy (SBRT) performed by VMAT technique in the oligometastatic patient setting. Conclusion The literature addressing the clinical appropriateness of VMAT is scarce. Current literature suggests that VMAT, especially when used as simultaneous integrated boost or SBRT strategy, is an effective safe modality for all cancer types.
Collapse
Affiliation(s)
| | | | - Savino Cilla
- Medical Physics Unit, "Giovanni Paolo II" Foundation, Catholic University of the Sacred Heart, Campobasso
| | - Silvia Cammelli
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Alessandra Guido
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Martina Ferioli
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Giambattista Siepe
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Vincenzo Valentini
- Department of Radiation Oncology, Catholic University of the Sacred Heart, Rome
| | - Alessio Giuseppe Morganti
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Gabriella Ferrandina
- Department of Obstetrics and Gynecology, Catholic University of the Sacred Heart, Rome.,Department of Health Sciences and Medicine, University of Molise, Campobasso, Italy
| |
Collapse
|
43
|
Murtaza G, Cora S, Khan EU. Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution. JOURNAL OF RADIATION RESEARCH 2017; 58:579-590. [PMID: 27974507 PMCID: PMC5569918 DOI: 10.1093/jrr/rrw114] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 06/07/2016] [Indexed: 06/06/2023]
Abstract
Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison of dose-volume indices (DIs) was made for partial-, single- and double-arc VMAT plans optimized at 2°, 3° and 4° GS, representing a large variation in deliverable multileaf collimator segments. VMAT plans of six prostate cancer and six head-and-neck cancer patients were simulated for an Elekta SynergyS® Linac (Elekta Ltd, Crawley, UK), using the SmartArc™ module of Pinnacle³ TPS, (version 9.2, Philips Healthcare). All optimization techniques generated clinically acceptable VMAT plans, except for the single-arc for the head-and-neck cancer patients. Plan quality was assessed by comparing the DIs for the planning target volume, organs at risk and normal tissue. A GS of 2°, with finest resolution and consequently highest intensity modulation, was considered to be the reference, and this was compared with GS 3° and 4°. The differences between the majority of reference DIs and compared DIs were <2%. The metrics, such as treatment plan optimization time and pretreatment (phantom) dosimetric calculation time, supported the use of a GS of 4°. The ArcCHECK™ phantom-measured dosimetric agreement verifications resulted in a >95.0% passing rate, using the criteria for γ (3%, 3 mm). In conclusion, a GS of 4° is an optimal choice for minimal usage of planning resources without compromise of plan quality.
Collapse
Affiliation(s)
- Ghulam Murtaza
- Medical Physics Department, San Bortolo Hospital, Vicenza, Italy
- Physics Department, International Islamic University Islamabad, Pakistan
| | - Stefania Cora
- Medical Physics Department, San Bortolo Hospital, Vicenza, Italy
| | - Ehsan Ullah Khan
- Physics Department, International Islamic University Islamabad, Pakistan
| |
Collapse
|
44
|
Analysis of Influence of Errors in Angular Settings of Couch and Collimator on the Dosimetric and Radiobiological Parameters in VMAT Plans. J Med Imaging Radiat Sci 2017; 48:166-177. [DOI: 10.1016/j.jmir.2016.10.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 10/12/2016] [Accepted: 10/25/2016] [Indexed: 12/25/2022]
|
45
|
Park JM, Kim K, Park JI, Shin KH, Jin US, Kim JI. Dosimetric effect of internal metallic ports in temporary tissue expanders on postmastectomy radiation therapy: a Monte Carlo study. Phys Med Biol 2017; 62:4623-4636. [DOI: 10.1088/1361-6560/aa700d] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
46
|
Park JY, Li F, Li J, Kahler D, Park JC, Yan G, Liu C, Lu B. Angular under-sampling effect on VMAT dose calculation: An analysis and a solution strategy. Med Phys 2017; 44:2096-2114. [PMID: 28370002 DOI: 10.1002/mp.12250] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Revised: 02/22/2017] [Accepted: 03/24/2017] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Most VMAT algorithms compute the dose on discretized apertures with small angular separations for practical reasons. However, machines deliver the VMAT dose with a continuously moving MLC and gantry and a continuously changing dose rate. The computed dose can deviate from the delivered dose, especially if no, or loose, MLC movement constraints are applied for the VMAT optimization. The goal of this paper is to establish a simplified mathematical model to analyze the discrepancy between the VMAT plan calculation dose and the delivered dose and to provide a reasonable solution for clinical implementation. METHODS A simplified metric is first introduced to describe the discrepancy between doses computed with discretized apertures and a continuous delivery model. The delivery fluences were formed separately for six different leaf movement scenarios. The formula was then rewritten in a more general form. The correlation between discretized and continuous fluence is summarized using this general form. The Fourier analysis for the impacts from three separate factors - dose kernel width, aperture width, aperture distance - to the dose discrepancy is also presented in order to provide insight into the dose discrepancy caused by under-sampling in the frequency domain. Finally, a weighting-based interpolation (WBI) algorithm, which can improve the aperture interpolation efficiency, is proposed. The associated evaluation methods and criteria for the proposed algorithm are also given. RESULTS The comparisons between the WBI algorithm and the equal angular interpolation (EAI) method suggested that the proposed algorithm has a great advantage with regard to aperture number efficiency. To achieve a 90% gamma passing rate using the dose computed with apertures generated with 0.5° EAI, with the initial optimization apertures as the standard for the comparison, the WBI needs only 66% and 54% of the aperture numbers that the EAI method needs for a 2° and a 4° angular separation of the VMAT optimization, respectively. The results also suggested that the weighted dose error index value, Θ, can be used as a stopping criterion for an interpolation algorithm, e.g., WBI or EAI, or as an indicator for sampling level evaluations. The phantom results indicate that the gamma passing rate decreases with increasing depth, from the phantom surface to the iso center, for the plans computed with under-sampled apertures. No obvious variation trends were observed for the plans computed with well-sampled apertures. CONCLUSIONS The mathematical analysis suggests that the dose discrepancies due to under-sampling are strongly correlated with the aperture width, the distance between apertures, and the width of the dose kernel. The WBI algorithm proves to be an efficient aperture interpolation strategy and is useful for dose computation of VMAT plans.
Collapse
Affiliation(s)
- Ji-Yeon Park
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Feifei Li
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Jonathan Li
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Darren Kahler
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Justin C Park
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, 63110, USA
| | - Guanghua Yan
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Chihray Liu
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| | - Bo Lu
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida, 32610, USA
| |
Collapse
|
47
|
Abstract
This article is a short review of PET tracers, which have been used in clinical routine in single institutions. Preliminary anecdotal research supports the use of PET techniques in therapy planning of prostate cancer. The existing literature is discussed. For external beam radiation therapy, the biological target volume definition can only be based on PET imaging. There are not yet any prospective and randomized trials available; therefore, single-institution experiences cannot yet be recommended as clinical routine.
Collapse
Affiliation(s)
- Kalevi J A Kairemo
- Department of Molecular Radiotherapy, Docrates Cancer Center, Saukonpaadenranta 2, Helsinki FI-00180, Finland; Department of Nuclear Medicine, Docrates Cancer Center, Saukonpaadenranta 2, Helsinki FI-00180, Finland; Department of Nuclear Medicine, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Houston, TX 77030, USA.
| |
Collapse
|
48
|
Köhn J, Licher J, Mielke M, Loutfi-Krauss B, Blümer N, Heine B, Rödel C, Scherf C, Ramm U. Image movement of the Elekta EPID during gantry rotation: Effects on the verification of dose distributions. Phys Med 2017; 34:72-79. [DOI: 10.1016/j.ejmp.2017.01.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 12/31/2016] [Accepted: 01/26/2017] [Indexed: 11/29/2022] Open
|
49
|
Ho JH, Hagler S, Lujano C, Seng S, Starks C, Perrin K, Turner L, Court L. Can cost make a difference dosimetrically? Volumetric modulated arc therapy study for multileaf collimators of various widths for head and neck and prostate cancers. Med Dosim 2017; 42:12-17. [PMID: 28126474 DOI: 10.1016/j.meddos.2016.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 09/15/2016] [Accepted: 10/10/2016] [Indexed: 11/28/2022]
Abstract
Cancer is a global health issue that disproportionately kills based on stage of disease, cellular pathology, and genetics, to name a few. Another variable to consider in this ongoing fight is treatment machine complexity that leads to elevated development and purchasing cost, leading to a reduced use. Reducing the complexity (in hopes of lowering costs) would benefit underdeveloped, low- and middle-income countries by introducing newer treatment technology, as their currently accepted standards do not meet standards of more advanced, developed countries. In this study, unilateral head and neck (H&N), and prostate cases using volumetric modulated arc therapy (VMAT) were tested with multiple segment widths of 5, 10, 15, and 20mm to create treatable plans. Pinnacle 9.10v was used for planning purposes. A total of 12 cases were planned with varying multileaf collimator (MLC) widths. Treatment plans were evaluated retrospectively. Results show that altering the MLC widths from 5 through 20mm produces both comparable and treatable plans up to 99% and 98% target coverage for H&N and prostate, respectively, albeit clinically significant hot spots were shown to increase with increasing segment width. Furthermore, the results show that increasing widths can produce comparable treatment plans as measured against our current Food and Drug Administration (FDA)-approved treatment devices-leading to an increase in treatment efficacy in economically underdeveloped countries.
Collapse
Affiliation(s)
- Jong-Han Ho
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Shane Hagler
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Carrie Lujano
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Sopaul Seng
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Christine Starks
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Kelly Perrin
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Lehendrick Turner
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Laurence Court
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
50
|
Ren W, Sun C, Lu N, Xu Y, Han F, Liu YP, Dai J. Dosimetric comparison of intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy in patients with prostate cancer: a meta-analysis. J Appl Clin Med Phys 2016; 17:254-262. [PMID: 27929498 PMCID: PMC5690508 DOI: 10.1120/jacmp.v17i6.6464] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 08/13/2016] [Accepted: 08/10/2016] [Indexed: 11/23/2022] Open
Abstract
Intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) are two main radiotherapy techniques. The aim of this study is to explore which is the preferred technique in prostate treatment through the related publica-tions and meta-analysis. Two authors independently identified all relevant articles available regarding eligibility criteria on PubMed, Embase, and Cochrane Library databases until December 2015. Publication bias was evaluated with funnel plot, and statistical analyses were performed with Stata software. P < 0.05 was thought statistically significant. Ten studies comprised a total of 110 patients; in total 110 IMRT plans and 110 VMAT plans that were included in this study. V40, V60, and V70 of rectum were significantly decreased in VMAT than in IMRT. However, V50 of rectum and V40, V50, V60, V70 of bladder had no statistical differences between IMRI and VMAT plans. Compared with IMRT, the treatment time and MUs of VMAT were significantly lower. VMAT protects rectum better than IMRT and improves the delivery efficiency. VMAT may be the preferred modality for treating prostate cancer.
Collapse
Affiliation(s)
- Wenting Ren
- Cancer Hospital, National Cancer Center, Chinese Academy of Medical Sciences and Peking Union Medical College.
| | | | | | | | | | | | | |
Collapse
|