1
|
Bissonnette JP, Yap ML, Clarke K, Shessel A, Higgins J, Vines D, Atenafu EG, Becker N, Leavens C, Bezjak A, Jaffray DA, Sun A. Serial 4DCT/4DPET imaging to predict and monitor response for locally-advanced non-small cell lung cancer chemo-radiotherapy. Radiother Oncol 2018; 126:347-354. [DOI: 10.1016/j.radonc.2017.11.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 11/07/2017] [Accepted: 11/27/2017] [Indexed: 12/12/2022]
|
2
|
Thomas HM, Kinahan PE, Samuel JJE, Bowen SR. Impact of tumour motion compensation and delineation methods on FDG PET-based dose painting plan quality for NSCLC radiation therapy. J Med Imaging Radiat Oncol 2017; 62:81-90. [PMID: 29193781 DOI: 10.1111/1754-9485.12693] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Accepted: 10/18/2017] [Indexed: 12/25/2022]
Abstract
INTRODUCTION To quantitatively estimate the impact of different methods for both boost volume delineation and respiratory motion compensation of [18F] FDG PET/CT images on the fidelity of planned non-uniform 'dose painting' plans to the prescribed boost dose distribution. METHODS Six locally advanced non-small cell lung cancer (NSCLC) patients were retrospectively reviewed. To assess the impact of respiratory motion, time-averaged (3D AVG), respiratory phase-gated (4D GATED) and motion-encompassing (4D MIP) PET images were used. The boost volumes were defined using manual contour (MANUAL), fixed threshold (FIXED) and gradient search algorithm (GRADIENT). The dose painting prescription of 60 Gy base dose to the planning target volume and an integral dose of 14 Gy (total 74 Gy) was discretized into seven treatment planning substructures and linearly redistributed according to the relative SUV at every voxel in the boost volume. Fifty-four dose painting plan combinations were generated and conformity was evaluated using quality index VQ0.95-1.05, which represents the sum of planned dose voxels within 5% deviation from the prescribed dose. Trends in plan quality and magnitude of achievable dose escalation were recorded. RESULTS Different segmentation techniques produced statistically significant variations in maximum planned dose (P < 0.02), as well as plan quality between segmentation methods for 4D GATED and 4D MIP PET images (P < 0.05). No statistically significant differences in plan quality and maximum dose were observed between motion-compensated PET-based plans (P > 0.75). Low variability in plan quality was observed for FIXED threshold plans, while MANUAL and GRADIENT plans achieved higher dose with lower plan quality indices. CONCLUSIONS The dose painting plans were more sensitive to segmentation of boost volumes than PET motion compensation in this study sample. Careful consideration of boost target delineation and motion compensation strategies should guide the design of NSCLC dose painting trials.
Collapse
Affiliation(s)
- Hannah Mary Thomas
- Department of Radiation Oncology, School of Medicine, University of Washington, Seattle, Washington, USA.,Department of Physics, School of Advanced Sciences, VIT University, Vellore, India
| | - Paul E Kinahan
- Department of Radiology, School of Medicine, University of Washington, Seattle, Washington, USA
| | | | - Stephen R Bowen
- Department of Radiation Oncology, School of Medicine, University of Washington, Seattle, Washington, USA.,Department of Radiology, School of Medicine, University of Washington, Seattle, Washington, USA
| |
Collapse
|
3
|
Lee E, Zeng J, Miyaoka RS, Saini J, Kinahan PE, Sandison GA, Wong T, Vesselle HJ, Rengan R, Bowen SR. Functional lung avoidance and response-adaptive escalation (FLARE) RT: Multimodality plan dosimetry of a precision radiation oncology strategy. Med Phys 2017; 44:3418-3429. [PMID: 28453861 DOI: 10.1002/mp.12308] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 03/22/2017] [Accepted: 04/21/2017] [Indexed: 12/25/2022] Open
Abstract
PURPOSE Nonsmall cell lung cancer (NSCLC) patient radiation therapy (RT) is planned without consideration of spatial heterogeneity in lung function or tumor response. We assessed the dosimetric and clinical feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [99m Tc]MAA-SPECT/CT perfused lung while redistributing an escalated boost dose within [18 F]FDG-PET/CT-defined biological target volumes (BTV). METHODS Eight stage IIB-IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain < 20 Gy mean lung dose (MLD). Prescriptions included 60 Gy to the planning target volume (PTV) and concomitant boost of 74 Gy mean to biological target volumes (BTV = GTV + PET gradient segmentation) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial treatment planning systems via uptake threshold discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with volumetric modulated arc therapy (VMAT), proton pencil beam scanning (PBS) with 3%-3 mm robust optimization, and combination of PBS (avoidance) plus VMAT (escalation). The high boost dose region was evaluated within a standardized SUVpeak structure. FLARE RT plans were compared to reference VMAT plans. Linear regression between radiation dose to BTV and normalized FDG PET SUV at every voxel was conducted, from which Pearson linear correlation coefficients and regression slopes were extracted. Spearman rank correlation coefficients were estimated between radiation dose to lung and normalized SPECT uptake. Dosimetric differences between treatment modalities were evaluated by Friedman nonparametric paired test with multiple sampling correction. RESULTS No unacceptable violations of PTV and normal tissue objectives were observed in 24 FLARE RT plans. Compared to reference VMAT plans, FLARE VMAT plans achieved a higher mean dose to BTV (73.7 Gy 98195. 61.3 Gy), higher mean dose to SUVpeak (89.7 Gy vs. 60.8 Gy), and lower mean dose to highly perfused lung (7.3 Gy vs. 14.9 Gy). These dosimetric gains came at the expense of higher mean heart dose (9.4 Gy vs. 5.8 Gy) and higher maximum cord dose (50.1 Gy vs. 44.6 Gy) relative to the reference VMAT plans. Between FLARE plans, FLARE VMAT achieved higher dose to the SUVpeak ROI than FLARE PBS (89.7 Gy vs. 79.2 Gy, P = 0.01), while FLARE PBS delivered lower dose to lung than FLARE VMAT (11.9 Gy vs. 15.6 Gy, P < 0.001). Voxelwise linear dose redistribution slope between BTV dose and FDG PET uptake was higher in magnitude for FLARE PBS + VMAT (0.36 Gy per %SUVmax ) compared to FLARE VMAT (0.27 Gy per %SUVmax ) or FLARE PBS alone (0.17 Gy per %SUVmax ). CONCLUSIONS FLARE RT is clinically feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and VMAT for FDG PET dose escalation balanced target and normal tissue objective tradeoffs. These results provide a technical platform for testing of FLARE RT safety and efficacy within a precision radiation oncology trial.
Collapse
Affiliation(s)
- Eunsin Lee
- Department of Radiation Oncology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Jing Zeng
- Department of Radiation Oncology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Robert S Miyaoka
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Jatinder Saini
- Seattle Cancer Care Alliance Proton Therapy Center, 1570 N 115th Ave, Seattle, WA, 98133, USA
| | - Paul E Kinahan
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - George A Sandison
- Department of Radiation Oncology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Tony Wong
- Seattle Cancer Care Alliance Proton Therapy Center, 1570 N 115th Ave, Seattle, WA, 98133, USA
| | - Hubert J Vesselle
- Department of Radiology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Ramesh Rengan
- Department of Radiation Oncology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Stephen R Bowen
- Departments of Radiation Oncology and Radiology, University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA, 98195, USA
| |
Collapse
|
4
|
Hatt M, Lee JA, Schmidtlein CR, Naqa IE, Caldwell C, De Bernardi E, Lu W, Das S, Geets X, Gregoire V, Jeraj R, MacManus MP, Mawlawi OR, Nestle U, Pugachev AB, Schöder H, Shepherd T, Spezi E, Visvikis D, Zaidi H, Kirov AS. Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211. Med Phys 2017; 44:e1-e42. [PMID: 28120467 DOI: 10.1002/mp.12124] [Citation(s) in RCA: 134] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 12/09/2016] [Accepted: 01/04/2017] [Indexed: 12/14/2022] Open
Abstract
PURPOSE The purpose of this educational report is to provide an overview of the present state-of-the-art PET auto-segmentation (PET-AS) algorithms and their respective validation, with an emphasis on providing the user with help in understanding the challenges and pitfalls associated with selecting and implementing a PET-AS algorithm for a particular application. APPROACH A brief description of the different types of PET-AS algorithms is provided using a classification based on method complexity and type. The advantages and the limitations of the current PET-AS algorithms are highlighted based on current publications and existing comparison studies. A review of the available image datasets and contour evaluation metrics in terms of their applicability for establishing a standardized evaluation of PET-AS algorithms is provided. The performance requirements for the algorithms and their dependence on the application, the radiotracer used and the evaluation criteria are described and discussed. Finally, a procedure for algorithm acceptance and implementation, as well as the complementary role of manual and auto-segmentation are addressed. FINDINGS A large number of PET-AS algorithms have been developed within the last 20 years. Many of the proposed algorithms are based on either fixed or adaptively selected thresholds. More recently, numerous papers have proposed the use of more advanced image analysis paradigms to perform semi-automated delineation of the PET images. However, the level of algorithm validation is variable and for most published algorithms is either insufficient or inconsistent which prevents recommending a single algorithm. This is compounded by the fact that realistic image configurations with low signal-to-noise ratios (SNR) and heterogeneous tracer distributions have rarely been used. Large variations in the evaluation methods used in the literature point to the need for a standardized evaluation protocol. CONCLUSIONS Available comparison studies suggest that PET-AS algorithms relying on advanced image analysis paradigms provide generally more accurate segmentation than approaches based on PET activity thresholds, particularly for realistic configurations. However, this may not be the case for simple shape lesions in situations with a narrower range of parameters, where simpler methods may also perform well. Recent algorithms which employ some type of consensus or automatic selection between several PET-AS methods have potential to overcome the limitations of the individual methods when appropriately trained. In either case, accuracy evaluation is required for each different PET scanner and scanning and image reconstruction protocol. For the simpler, less robust approaches, adaptation to scanning conditions, tumor type, and tumor location by optimization of parameters is necessary. The results from the method evaluation stage can be used to estimate the contouring uncertainty. All PET-AS contours should be critically verified by a physician. A standard test, i.e., a benchmark dedicated to evaluating both existing and future PET-AS algorithms needs to be designed, to aid clinicians in evaluating and selecting PET-AS algorithms and to establish performance limits for their acceptance for clinical use. The initial steps toward designing and building such a standard are undertaken by the task group members.
Collapse
Affiliation(s)
- Mathieu Hatt
- INSERM, UMR 1101, LaTIM, University of Brest, IBSAM, Brest, France
| | - John A Lee
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | | | | | - Curtis Caldwell
- Sunnybrook Health Sciences Center, Toronto, ON, M4N 3M5, Canada
| | | | - Wei Lu
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Shiva Das
- University of North Carolina, Chapel Hill, NC, 27599, USA
| | - Xavier Geets
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | - Vincent Gregoire
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | - Robert Jeraj
- University of Wisconsin, Madison, WI, 53705, USA
| | | | | | - Ursula Nestle
- Universitätsklinikum Freiburg, Freiburg, 79106, Germany
| | - Andrei B Pugachev
- University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Heiko Schöder
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | | | - Emiliano Spezi
- School of Engineering, Cardiff University, Cardiff, Wales, United Kingdom
| | | | - Habib Zaidi
- Geneva University Hospital, Geneva, CH-1211, Switzerland
| | - Assen S Kirov
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| |
Collapse
|
5
|
Evaluating the use of optimally respiratory gated 18F-FDG-PET in target volume delineation and its influence on radiation doses to the organs at risk in non-small-cell lung cancer patients. Nucl Med Commun 2016; 37:66-73. [DOI: 10.1097/mnm.0000000000000409] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Jaffray DA, Chung C, Coolens C, Foltz W, Keller H, Menard C, Milosevic M, Publicover J, Yeung I. Quantitative Imaging in Radiation Oncology: An Emerging Science and Clinical Service. Semin Radiat Oncol 2015; 25:292-304. [PMID: 26384277 DOI: 10.1016/j.semradonc.2015.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Radiation oncology has long required quantitative imaging approaches for the safe and effective delivery of radiation therapy. The past 10 years has seen a remarkable expansion in the variety of novel imaging signals and analyses that are starting to contribute to the prescription and design of the radiation treatment plan. These include a rapid increase in the use of magnetic resonance imaging, development of contrast-enhanced imaging techniques, integration of fluorinated deoxyglucose-positron emission tomography, evaluation of hypoxia imaging techniques, and numerous others. These are reviewed with an effort to highlight challenges related to quantification and reproducibility. In addition, several of the emerging applications of these imaging approaches are also highlighted. Finally, the growing community of support for establishing quantitative imaging approaches as we move toward clinical evaluation is summarized and the need for a clinical service in support of the clinical science and delivery of care is proposed.
Collapse
Affiliation(s)
- David Anthony Jaffray
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
| | - Caroline Chung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Catherine Coolens
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Warren Foltz
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Harald Keller
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Cynthia Menard
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Michael Milosevic
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Julia Publicover
- TECHNA Institute/University Health Network, Toronto, Ontario, Canada
| | - Ivan Yeung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
7
|
Bowen SR, Nyflot MJ, Herrmann C, Groh CM, Meyer J, Wollenweber SD, Stearns CW, Kinahan PE, Sandison GA. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study. Phys Med Biol 2015; 60:3731-46. [PMID: 25884892 DOI: 10.1088/0031-9155/60/9/3731] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.
Collapse
Affiliation(s)
- S R Bowen
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA, USA. Department of Radiology, University of Washington School of Medicine, Seattle, WA, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Jiang C, Han Y, Hu X, Yang B, Tang T, Chen X, Zhao H. Relative low glycometabolism may also occur in invasive lung adenocarcinoma with visceral pleural invasion: case report and comments. Medicine (Baltimore) 2014; 93:e254. [PMID: 25474437 PMCID: PMC4616387 DOI: 10.1097/md.0000000000000254] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Lung cancer is the main cause of cancer deaths in the world and positron emission tomography (PET) is considered as the most accurate diagnosis and staging technique for lung cancer. For human cancers, fluorodeoxyglucose (FDG)-PET imaging of most primary and metastatic tumors will show significantly increased glucose uptake because high metabolic activity of cancer cells. But there still have the question of false negative or positive rates in diagnostic accuracy need to be considered.A 51 year old man was diagnosed a lung tumor in the right middle lobe without enlargement of lymph nodes by computed tomography (CT). The F-FDG-PET/CT presented 1 slight increased metabolism in the tumor region. After resection of the tumor, postoperative pathological examination confirmed that it was invasive lung adenocarcinoma and with visceral pleural invasion while showed relative low glucose absorption in PET/CT.A form of invasive lung adenocarcinoma was diagnosized. The tumor tissues were further confirmed by immunohistochemical assessments, which showed that thyroid transcription factor 1 (TTF-1 or NKX2-1) and Cytokeratin 7 (CK7) were all significant positive.Diagnosis of lung cancer even all other cancers by FDG-PET should be carefully considered the question of accuracy. Our case has added additional literature for us to considering the false-negative of lung cancer diagnosis by F-FDG-PET/CT.
Collapse
Affiliation(s)
- Chunyang Jiang
- From the Department of Thoracic Surgery, Tianjin Union Medicine Centre, 190 Jieyuan Road, Hongqiao District, Tianjin 300121 (CJ, YH, BY, HZ); Department of Respiratory Medicine, People's Hospital of Qitaihe City, 37 Shanhu Road, Qitaihe 154600, Heilongjiang (XH); Department of Pathology, Tianjin Union Medicine Centre, 190 Jieyuan Road, Hongqiao District, Tianjin 300121 (TT); and Department of Microbiology & Infectious Disease Center, School of Basic Medical Science, Peking University Health Science Center, 38 Xueyuan Road, Beijing 100191, People's Republic of China (XC)
| | | | | | | | | | | | | |
Collapse
|
9
|
Chi A, Nguyen NP. The utility of positron emission tomography in the treatment planning of image-guided radiotherapy for non-small cell lung cancer. Front Oncol 2014; 4:273. [PMID: 25340040 PMCID: PMC4187610 DOI: 10.3389/fonc.2014.00273] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 09/20/2014] [Indexed: 11/17/2022] Open
Abstract
In the thorax, the extent of tumor may be more accurately defined with the addition of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to computed tomography (CT). This led to the increased utility of FDG-PET or PET/CT in the treatment planning of radiotherapy for non-small cell lung cancer (NSCLC). The inclusion of FDG-PET information in target volume delineation not only improves tumor localization but also decreases the amount of normal tissue included in the planning target volume (PTV) in selected patients. Therefore, it has a critical role in image-guided radiotherapy (IGRT) for NSCLC. In this review, the impact of FDG-PET on target volume delineation in radiotherapy for NSCLC, which may increase the possibility of safe dose escalation with IGRT, the commonly used methods for tumor target volume delineation FDG-PET for NSCLC, and its impact on clinical outcome will be discussed.
Collapse
Affiliation(s)
- Alexander Chi
- Department of Radiation Oncology, Mary Babb Randolph Cancer Center, West Virginia University , Morgantown, WV , USA
| | - Nam P Nguyen
- International Geriatric Radiotherapy Group , Tucson, AZ , USA
| |
Collapse
|
10
|
Bowen SR, Pierce LA, Alessio AM, Liu C, Wollenweber SD, Stearns CW, Kinahan PE. Assessment of patient selection criteria for quantitative imaging with respiratory-gated positron emission tomography. J Med Imaging (Bellingham) 2014; 1:026001. [PMID: 26158039 DOI: 10.1117/1.jmi.1.2.026001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Revised: 09/03/2014] [Accepted: 09/03/2014] [Indexed: 12/25/2022] Open
Abstract
The objective of this investigation was to propose techniques for determining which patients are likely to benefit from quantitative respiratory-gated imaging by correlating respiratory patterns to changes in positron emission tomography (PET) metrics. Twenty-six lung and liver cancer patients underwent PET/computed tomography exams with recorded chest/abdominal displacements. Static and adaptive amplitude-gated [[Formula: see text]]fluoro-D-glucose (FDG) PET images were generated from list-mode acquisitions. Patients were grouped by respiratory pattern, lesion location, or degree of lesion attachment to anatomical structures. Respiratory pattern metrics were calculated during time intervals corresponding to PET field of views over lesions of interest. FDG PET images were quantified by lesion maximum standardized uptake value ([Formula: see text]). Relative changes in [Formula: see text] between static and gated PET images were tested for association to respiratory pattern metrics. Lower lung lesions and liver lesions had significantly higher changes in [Formula: see text] than upper lung lesions (14 versus 3%, [Formula: see text]). Correlation was highest ([Formula: see text], [Formula: see text], [Formula: see text]) between changes in [Formula: see text] and nonstandard respiratory pattern metrics. Lesion location had a significant impact on changes in PET quantification due to respiratory gating. Respiratory pattern metrics were correlated to changes in [Formula: see text], though sample size limited statistical power. Validation in larger cohorts may enable selection of patients prior to acquisition who would benefit from respiratory-gated PET imaging.
Collapse
Affiliation(s)
- Stephen R Bowen
- University of Washington School of Medicine , Department of Radiation Oncology, 1959 NE Pacific St, Seattle, Washington 98195, United States ; University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Larry A Pierce
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Adam M Alessio
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Chi Liu
- Yale University School of Medicine , Department of Diagnostic Radiology, New Haven, Connecticut 06510, United States
| | | | | | - Paul E Kinahan
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| |
Collapse
|
11
|
Chi A, Nguyen NP. 4D PET/CT as a Strategy to Reduce Respiratory Motion Artifacts in FDG-PET/CT. Front Oncol 2014; 4:205. [PMID: 25136514 PMCID: PMC4120690 DOI: 10.3389/fonc.2014.00205] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 07/16/2014] [Indexed: 01/08/2023] Open
Abstract
The improved accuracy in tumor identification with FDG-PET has led to its increased utilization in target volume delineation for radiotherapy treatment planning in the treatment of lung cancer. However, PET/CT has constantly been influenced by respiratory motion-related image degradation, which is especially prominent for small lung tumors in the peri-diaphragmatic regions of the thorax. Here, we describe the current findings on respiratory motion-related image degradation in PET/CT, which may bring uncertainties to target volume delineation for image guided radiotherapy (IGRT) for lung cancer. Furthermore, we describe the evidence suggesting 4D PET/CT to be one strategy to minimize the impact of respiratory motion-related image degradation on tumor target delineation for thoracic IGRT. This, in our opinion, warrants further investigation in future IGRT-based lung cancer trials.
Collapse
Affiliation(s)
- Alexander Chi
- Department of Radiation Oncology, Mary Babb Randolph Cancer Center, West Virginia University , Morgantown, WV , USA
| | - Nam P Nguyen
- The International Geriatric Radiotherapy Group , Tucson, AZ , USA
| |
Collapse
|
12
|
Wang S, Bowen SR, Chaovalitwongse WA, Sandison GA, Grabowski TJ, Kinahan PE. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification. Phys Med Biol 2014; 59:1027-45. [PMID: 24504153 DOI: 10.1088/0031-9155/59/4/1027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV(peak)) over lesions of interest. Relative differences in SUV(peak) between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV(peak) values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.
Collapse
Affiliation(s)
- Shouyi Wang
- Department of Industrial and Systems Engineering, 3900 Stevens Way, Seattle, WA 98195, USA. Integrated Brain Imaging Center, 1959 NE Pacific St, Seattle, WA 98195, USA
| | | | | | | | | | | |
Collapse
|
13
|
Jani SS, Robinson CG, Dahlbom M, White BM, Thomas DH, Gaudio S, Low DA, Lamb JM. A comparison of amplitude-based and phase-based positron emission tomography gating algorithms for segmentation of internal target volumes of tumors subject to respiratory motion. Int J Radiat Oncol Biol Phys 2013; 87:562-9. [PMID: 24074930 DOI: 10.1016/j.ijrobp.2013.06.2042] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 06/11/2013] [Accepted: 06/15/2013] [Indexed: 11/25/2022]
Abstract
PURPOSE To quantitatively compare the accuracy of tumor volume segmentation in amplitude-based and phase-based respiratory gating algorithms in respiratory-correlated positron emission tomography (PET). METHODS AND MATERIALS List-mode fluorodeoxyglucose-PET data was acquired for 10 patients with a total of 12 fluorodeoxyglucose-avid tumors and 9 lymph nodes. Additionally, a phantom experiment was performed in which 4 plastic butyrate spheres with inner diameters ranging from 1 to 4 cm were imaged as they underwent 1-dimensional motion based on 2 measured patient breathing trajectories. PET list-mode data were gated into 8 bins using 2 amplitude-based (equal amplitude bins [A1] and equal counts per bin [A2]) and 2 temporal phase-based gating algorithms. Gated images were segmented using a commercially available gradient-based technique and a fixed 40% threshold of maximum uptake. Internal target volumes (ITVs) were generated by taking the union of all 8 contours per gated image. Segmented phantom ITVs were compared with their respective ground-truth ITVs, defined as the volume subtended by the tumor model positions covering 99% of breathing amplitude. Superior-inferior distances between sphere centroids in the end-inhale and end-exhale phases were also calculated. RESULTS Tumor ITVs from amplitude-based methods were significantly larger than those from temporal-based techniques (P=.002). For lymph nodes, A2 resulted in ITVs that were significantly larger than either of the temporal-based techniques (P<.0323). A1 produced the largest and most accurate ITVs for spheres with diameters of ≥2 cm (P=.002). No significant difference was shown between algorithms in the 1-cm sphere data set. For phantom spheres, amplitude-based methods recovered an average of 9.5% more motion displacement than temporal-based methods under regular breathing conditions and an average of 45.7% more in the presence of baseline drift (P<.001). CONCLUSIONS Target volumes in images generated from amplitude-based gating are larger and more accurate, at levels that are potentially clinically significant, compared with those from temporal phase-based gating.
Collapse
Affiliation(s)
- Shyam S Jani
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, California.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Rusten E, Rødal J, Revheim ME, Skretting A, Bruland OS, Malinen E. Quantitative dynamic ¹⁸FDG-PET and tracer kinetic analysis of soft tissue sarcomas. Acta Oncol 2013. [PMID: 23198721 DOI: 10.3109/0284186x.2012.728713] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To study soft tissue sarcomas using dynamic positron emission tomography (PET) with the glucose analog tracer [(18)F]fluoro-2-deoxy-D-glucose ((18)FDG), to investigate correlations between derived PET image parameters and clinical characteristics, and to discuss implications of dynamic PET acquisition (D-PET). MATERIAL AND METHODS D-PET images of 11 patients with soft tissue sarcomas were analyzed voxel-by-voxel using a compartment tracer kinetic model providing estimates of transfer rates between the vascular, non-metabolized, and metabolized compartments. Furthermore, standard uptake values (SUVs) in the early (2 min p.i.; SUVE) and late (45 min p.i.; SUVL) phases of the PET acquisition were obtained. The derived transfer rates K1, k2 and k3, along with the metabolic rate of (18)FDG (MRFDG) and the vascular fraction νp, was fused with the computed tomography (CT) images for visual interpretation. Correlations between D-PET imaging parameters and clinical parameters, i.e. tumor size, grade and clinical status, were calculated with a significance level of 0.05. RESULTS The temporal uptake pattern of (18)FDG in the tumor varied considerably from patient to patient. SUVE peak was higher than SUVL peak for four patients. The images of the rate constants showed a systematic pattern, often with elevated intensity in the tumors compared to surrounding tissue. Significant correlations were found between SUVE/L and some of the rate parameters. CONCLUSIONS Dynamic (18)FDG-PET may provide additional valuable information on soft tissue sarcomas not obtainable from conventional (18)FDG-PET. The prognostic role of dynamic imaging should be investigated.
Collapse
Affiliation(s)
- Espen Rusten
- Department of Medical Physics, The Norwegian Radium Hospital, Oslo University Hospital, Oslo, Norway
| | | | | | | | | | | |
Collapse
|
15
|
Mawlawi OR, Court LE. Four-Dimensional PET-CT in Radiation Oncology. PET Clin 2013; 8:81-94. [DOI: 10.1016/j.cpet.2012.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
|
16
|
Hugo GD, Rosu M. Advances in 4D radiation therapy for managing respiration: part I - 4D imaging. Z Med Phys 2012; 22:258-71. [PMID: 22784929 PMCID: PMC4153750 DOI: 10.1016/j.zemedi.2012.06.009] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2012] [Revised: 06/14/2012] [Accepted: 06/18/2012] [Indexed: 11/21/2022]
Abstract
Techniques for managing respiration during imaging and planning of radiation therapy are reviewed, concentrating on free-breathing (4D) approaches. First, we focus on detailing the historical development and basic operational principles of currently-available "first generation" 4D imaging modalities: 4D computed tomography, 4D cone beam computed tomography, 4D magnetic resonance imaging, and 4D positron emission tomography. Features and limitations of these first generation systems are described, including necessity of breathing surrogates for 4D image reconstruction, assumptions made in acquisition and reconstruction about the breathing pattern, and commonly-observed artifacts. Both established and developmental methods to deal with these limitations are detailed. Finally, strategies to construct 4D targets and images and, alternatively, to compress 4D information into static targets and images for radiation therapy planning are described.
Collapse
Affiliation(s)
- Geoffrey D Hugo
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298, USA.
| | | |
Collapse
|
17
|
Hatt M, Maitre AL, Wallach D, Fayad H, Visvikis D. Comparison of different methods of incorporating respiratory motion for lung cancer tumor volume delineation on PET images: a simulation study. Phys Med Biol 2012; 57:7409-30. [PMID: 23093372 DOI: 10.1088/0031-9155/57/22/7409] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The interest of PET complementary information for the delineation of the target volume in radiotherapy of lung cancer is increasing. However, respiratory motion requires the determination of a functional internal target volume (ITV) on PET images for which several strategies have been proposed. The purpose of this study was the comparison of these strategies for taking into account respiratory motion and deriving the ITV: (1) adding fixed margins to the volume defined on a single binned image, (2) segmenting a motion averaged image and (3) considering the union of volumes delineated on binned frames. For this third strategy, binned frames were either non-corrected for motion, or corrected using two different methods: elastic registration or super resolution. The strategies' performances were assessed on realistic simulated datasets combining the NCAT phantom with a PET Philips GEMINI scanner model in GATE, and containing various configurations of tumor to background contrast, with both regular and irregular respiratory motion (with a range of motion amplitudes). The obtained ITVs' sensitivity (SE) and positive predictive value (PVE) with respect to the known true ITV were significantly higher (from 0.8 to 0.95) than all other techniques when using binned frames corrected for motion, independently of motion regularity, amplitude, or tumor to background contrast. Although the absolute difference was small and not always significant, images corrected using super resolution led to systematically better results than using elastic registration. The worst results were obtained when using the motion averaged image for SE (around 0.5-0.6) and using the margins added to a single frame for PPV (0.6-0.7), respectively. The best strategy to account for breathing motion for tumor ITV delineation in radiotherapy planning is to rely on the use of the union of volumes delineated on super resolution-corrected binned images.
Collapse
Affiliation(s)
- Mathieu Hatt
- INSERM, UMR 1101 LaTIM, CHRU Morvan, Brest, France.
| | | | | | | | | |
Collapse
|
18
|
Bowen SR, Nyflot MJ, Gensheimer M, Hendrickson KRG, Kinahan PE, Sandison GA, Patel SA. Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: review and perspective. Clin Transl Med 2012; 1:18. [PMID: 23369522 PMCID: PMC3560984 DOI: 10.1186/2001-1326-1-18] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Accepted: 07/25/2012] [Indexed: 12/25/2022] Open
Abstract
The increasing interest in combined positron emission tomography (PET) and computed tomography (CT) to guide lung cancer radiation therapy planning has been well documented. Motion management strategies during treatment simulation PET/CT imaging and treatment delivery have been proposed to improve the precision and accuracy of radiotherapy. In light of these research advances, why has translation of motion-managed PET/CT to clinical radiotherapy been slow and infrequent? Solutions to this problem are as complex as they are numerous, driven by large inter-patient variability in tumor motion trajectories across a highly heterogeneous population. Such variation dictates a comprehensive and patient-specific incorporation of motion management strategies into PET/CT-guided radiotherapy rather than a one-size-fits-all tactic. This review summarizes challenges and opportunities for clinical translation of advances in PET/CT-guided radiotherapy, as well as in respiratory motion-managed radiotherapy of lung cancer. These two concepts are then integrated into proposed patient-specific workflows that span classification schemes, PET/CT image formation, treatment planning, and adaptive image-guided radiotherapy delivery techniques.
Collapse
Affiliation(s)
- Stephen R Bowen
- University of Washington Medical Center, Department of Radiation Oncology, 1959 NE Pacific St, Box 356043, Seattle, WA 98195, USA.
| | | | | | | | | | | | | |
Collapse
|
19
|
Aristophanous M, Yong Y, Yap JT, Killoran JH, Allen AM, Berbeco RI, Chen AB. Evaluating FDG uptake changes between pre and post therapy respiratory gated PET scans. Radiother Oncol 2012; 102:377-82. [PMID: 22265731 DOI: 10.1016/j.radonc.2011.12.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Revised: 11/07/2011] [Accepted: 12/23/2011] [Indexed: 12/21/2022]
Abstract
PURPOSE Whole body (3D) and respiratory gated (4D) FDG-PET/CT scans performed pre-radiotherapy (pre-RT) and post-radiotherapy (post-RT) were analyzed to investigate the impact of 4D PET in evaluating 18F-fluorodeoxyglucose (FDG) uptake changes due to therapy, relative to traditional 3D PET. METHODS AND MATERIALS 3D and 4D sequential FDG-PET/CT scans were acquired pre-RT and approximately one month post-RT for patients with non-small cell lung cancer (NSCLC). The lesions of high uptake targeted with radiotherapy were identified on the pre-RT scan of each patient. Each lesion on the 3D and each of the five phases of the 4D scan were analyzed using a region of interest (ROI). For each patient the ROIs of the pre-RT scans were used to locate the areas of initial FDG uptake on the post-RT scans following rigid registration. Post-RT ROIs were drawn and the FDG uptake was compared with that of the pre-RT scans. RESULTS Sixteen distinct lesions from 12 patients were identified and analyzed. Standardized uptake value (SUV) maxima were significantly higher (p-value <0.005) for the lesions as measured on the 4D compared to 3D PET. Comparison of serial pre and post-RT scans showed a mean 62% decrease in SUV with the 3D PET scan (range 36-89%), and a 67% decrease with the 4D PET scan (range 30-89%). The mean absolute difference in SUV change on 3D versus 4D scans was 4.9%, with a range 0-15% (p-value = 0.07). CONCLUSIONS Signal recovery with 4D PET results in higher SUVs when compared to standard 3D PET. Consequently, differences in the evaluation of SUV changes between pre and post-RT plans were observed. Such difference can have a significant impact in PET-based response assessment.
Collapse
Affiliation(s)
- Michalis Aristophanous
- Department of Radiation Oncology, Dana-Farber/Brigham and Women's Cancer Center and Harvard Medical School, Boston, MA, USA.
| | | | | | | | | | | | | |
Collapse
|
20
|
Hatt M, Boussion N, Cheze-Le Rest C, Visvikis D, Pradier O. [Metabolically active volumes automatic delineation methodologies in PET imaging: review and perspectives]. Cancer Radiother 2011; 16:70-81; quiz 82, 84. [PMID: 22041031 DOI: 10.1016/j.canrad.2011.07.243] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2011] [Revised: 05/31/2011] [Accepted: 07/04/2011] [Indexed: 12/26/2022]
Abstract
PET imaging is now considered a gold standard tool in clinical oncology, especially for diagnosis purposes. More recent applications such as therapy follow-up or tumor targeting in radiotherapy require a fast, accurate and robust metabolically active tumor volumes delineation on emission images, which cannot be obtained through manual contouring. This clinical need has sprung a large number of methodological developments regarding automatic methods to define tumor volumes on PET images. This paper reviews most of the methodologies that have been recently proposed and discusses their framework and methodological and/or clinical validation. Perspectives regarding the future work to be done are also suggested.
Collapse
Affiliation(s)
- M Hatt
- Inserm U650 LaTIM, CHU Morvan, 5, avenue Foch, 29609 Brest, France.
| | | | | | | | | |
Collapse
|
21
|
Hatt M, Cheze-le Rest C, van Baardwijk A, Lambin P, Pradier O, Visvikis D. Impact of tumor size and tracer uptake heterogeneity in (18)F-FDG PET and CT non-small cell lung cancer tumor delineation. J Nucl Med 2011; 52:1690-7. [PMID: 21990577 DOI: 10.2967/jnumed.111.092767] [Citation(s) in RCA: 111] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED The objectives of this study were to investigate the relationship between CT- and (18)F-FDG PET-based tumor volumes in non-small cell lung cancer (NSCLC) and the impact of tumor size and uptake heterogeneity on various approaches to delineating uptake on PET images. METHODS Twenty-five NSCLC cancer patients with (18)F-FDG PET/CT were considered. Seventeen underwent surgical resection of their tumor, and the maximum diameter was measured. Two observers manually delineated the tumors on the CT images and the tumor uptake on the corresponding PET images, using a fixed threshold at 50% of the maximum (T(50)), an adaptive threshold methodology, and the fuzzy locally adaptive Bayesian (FLAB) algorithm. Maximum diameters of the delineated volumes were compared with the histopathology reference when available. The volumes of the tumors were compared, and correlations between the anatomic volume and PET uptake heterogeneity and the differences between delineations were investigated. RESULTS All maximum diameters measured on PET and CT images significantly correlated with the histopathology reference (r > 0.89, P < 0.0001). Significant differences were observed among the approaches: CT delineation resulted in large overestimation (+32% ± 37%), whereas all delineations on PET images resulted in underestimation (from -15% ± 17% for T(50) to -4% ± 8% for FLAB) except manual delineation (+8% ± 17%). Overall, CT volumes were significantly larger than PET volumes (55 ± 74 cm(3) for CT vs. from 18 ± 25 to 47 ± 76 cm(3) for PET). A significant correlation was found between anatomic tumor size and heterogeneity (larger lesions were more heterogeneous). Finally, the more heterogeneous the tumor uptake, the larger was the underestimation of PET volumes by threshold-based techniques. CONCLUSION Volumes based on CT images were larger than those based on PET images. Tumor size and tracer uptake heterogeneity have an impact on threshold-based methods, which should not be used for the delineation of cases of large heterogeneous NSCLC, as these methods tend to largely underestimate the spatial extent of the functional tumor in such cases. For an accurate delineation of PET volumes in NSCLC, advanced image segmentation algorithms able to deal with tracer uptake heterogeneity should be preferred.
Collapse
|