1
|
Keijnemans K, Borman PTS, Raaymakers BW, Fast MF. Effectiveness of visual biofeedback-guided respiratory-correlated 4D-MRI for radiotherapy guidance on the MR-linac. Magn Reson Med 2024; 91:297-311. [PMID: 37799101 DOI: 10.1002/mrm.29857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 08/18/2023] [Accepted: 08/18/2023] [Indexed: 10/07/2023]
Abstract
PURPOSE Respiratory-correlated 4D-MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D-MRI acquisitions on an MR-linac. METHODS A simultaneous multislice-accelerated 4D-MRI sequence was interleaved with a one-dimensional respiratory navigator (1D-RNAV) in 10 healthy volunteers on a 1.5T Unity MR-linac (Elekta AB, Stockholm, Sweden). Volunteer-specific breathing amplitudes and periods were derived from the 1D-RNAV signal obtained during unguided 4D-MRI acquisitions. These were used for the guidance waveform, while the 1D-RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation (CV diff $$ {\mathrm{CV}}^{\mathrm{diff}} $$ ) for the breathing amplitude and period, the position SD of end-exhale, end-inhale and midposition locations, and the agreement between the 1D-RNAV signals and guidance waveforms. The 4D-MRI quality was assessed by quantifying amounts of missing data. RESULTS VBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from -3% to 35% (end-exhale), 29% to 38% (end-inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D-RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%. CONCLUSION A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D-MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory-correlated 4D-MRI.
Collapse
Affiliation(s)
- Katrinus Keijnemans
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pim T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Bas W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
2
|
Artunduaga M, Liu CA, Morin CE, Serai SD, Udayasankar U, Greer MLC, Gee MS. Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations. Pediatr Radiol 2021; 51:724-735. [PMID: 33860861 PMCID: PMC8049862 DOI: 10.1007/s00247-021-05044-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 01/17/2021] [Accepted: 03/01/2021] [Indexed: 12/17/2022]
Abstract
The use of sedation and general anesthesia has facilitated the significant growth of MRI use among children over the last years. While sedation and general anesthesia are considered to be relatively safe, their use poses potential risks in the short term and in the long term. This manuscript reviews the reasons why MRI examinations require sedation and general anesthesia more commonly in the pediatric population, summarizes the safety profile of sedation and general anesthesia, and discusses an amalgam of strategies that can be implemented and can ultimately lead to the optimization of sedation and general anesthesia care within pediatric radiology departments.
Collapse
Affiliation(s)
- Maddy Artunduaga
- Pediatric Radiology Division, Department of Radiology, University of Texas Southwestern Medical Center, Children's Health Medical Center,, 5323 Harry Hines Blvd., CMC F1.02, Dallas, TX, 75390, USA.
- Children's Health Medical Center, Dallas, TX, USA.
| | - C Amber Liu
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Cara E Morin
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Unni Udayasankar
- Department of Medical Imaging, The University of Arizona Health Sciences, Tucson, AZ, USA
| | - Mary-Louise C Greer
- Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada
- Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Michael S Gee
- Harvard Medical School, Boston, MA, USA
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
3
|
Wikström KA, Isacsson UM, Pinto MC, Nilsson KM, Ahnesjö A. Evaluation of irregular breathing effects on internal target volume definition for lung cancer radiotherapy. Med Phys 2021; 48:2136-2144. [PMID: 33668075 DOI: 10.1002/mp.14824] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 01/13/2021] [Accepted: 02/22/2021] [Indexed: 11/12/2022] Open
Abstract
PURPOSE Irregular breathing may compromise the treated volume for free-breathing lung cancer patients during radiotherapy. We try to find a measure based on a breathing amplitude surrogate that can be used to select the patients who need further investigation of tumor motion to ensure that the internal target volume (ITV) provides reliant coverage of the tumor. MATERIAL AND METHODS Fourteen patients were scanned with four-dimensional computed tomography (4DCT) during free-breathing. The breathing motion was detected by a pneumatic bellows device used as a breathing amplitude surrogate. In addition to the 4DCT, a breath-hold (BH) scan and three cine CT imaging sessions were acquired. The cine images were taken at randomized intervals at a rate of 12 per minute for 8 minutes to allow tumor motion determination during a typical hypo-fractionated treatment scenario. A clinical target volume (CTV) was segmented in the BH CT and propagated over all cine images and 4DCT bins. The center-of-volume of the translated CTV (CTVCOV ) in the ten 4DCT bins were interconnected to define the 4DCT determined tumor trajectory (4DCT-TT). The volume of CTV inside ITV for all cine CTs was calculated and reported at the 10th percentile (VCTV10% ). The deviations between CTVCOV in the cine CTs and the 4DCT-TT were calculated and reported at its 90th percentile (d90% ). The standard deviation of the bellows amplitude peaks (SDP) and the ratio between large and normal inspirations, κrel , were tested as surrogates for VCTV10% and d90% . RESULTS The values of d90% ranged from 0.6 to 5.2 mm with a mean of 2.2 mm. The values of VCTV10% ranged from 59-93% with a mean of 78 %. The SDP had a moderate correlation (r = 0.87) to d90% . Less correlation was seen between SDP and VCTV10% (r = 0.77), κrel and d90% (r = 0.75) and finally κrel and VCTV10% (r = 0.75). CONCLUSIONS The ITV coverage had a large variation for some patients. SDP seems to be a feasible surrogate measure to select patients that needs further tumor motion determination.
Collapse
Affiliation(s)
- Kenneth A Wikström
- Medical Radiation Physics, Uppsala University Hospital, 751 85, Uppsala, Sweden.,Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, 751 85, Uppsala, Sweden
| | - Ulf M Isacsson
- Medical Radiation Physics, Uppsala University Hospital, 751 85, Uppsala, Sweden.,Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, 751 85, Uppsala, Sweden
| | - Marta C Pinto
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, 751 85, Uppsala, Sweden.,Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Anders Ahnesjö
- Medical Radiation Physics, Uppsala University Hospital, 751 85, Uppsala, Sweden.,Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, 751 85, Uppsala, Sweden
| |
Collapse
|
4
|
Perkins T, Lee D, Simpson J, Greer P, Goodwin J. Experimental evaluation of four-dimensional Magnetic Resonance Imaging for radiotherapy planning of lung cancer. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 17:32-35. [PMID: 33898775 PMCID: PMC8058028 DOI: 10.1016/j.phro.2020.12.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 12/18/2020] [Accepted: 12/22/2020] [Indexed: 12/25/2022]
Abstract
Radiotherapy planning for lung cancer typically requires both 3D and 4D Computed Tomography (CT) to account for respiratory related movement. 4D Magnetic Resonance Imaging (MRI) with self-navigation offers a potential alternative with greater reliability in patients with irregular breathing patterns and improved soft tissue contrast. In this study 4D-CT and a 4D-MRI Radial Volumetric Interpolated Breath-hold Examination (VIBE) sequence was evaluated with a 4D phantom and 13 patient respiratory patterns, simulating tumour motion. Quantification of motion related tumour displacement in 4D-MRI and 4D-CT found no statistically significant difference in mean motion range. The results demonstrated the potential viability of 4D-MRI for lung cancer treatment planning.
Collapse
Affiliation(s)
- Terry Perkins
- Blacktown Cancer & Haematology Centre, Blacktown Hospital, NSW, Australia.,School of Physics, University of Sydney, Australia
| | - Danny Lee
- School of Mathematical and Physical Science, University of Newcastle, Australia
| | - John Simpson
- Radiation Oncology, Calvary Mater Newcastle, Australia.,School of Mathematical and Physical Science, University of Newcastle, Australia
| | - Peter Greer
- Radiation Oncology, Calvary Mater Newcastle, Australia.,School of Mathematical and Physical Science, University of Newcastle, Australia
| | - Jonathan Goodwin
- Radiation Oncology, Calvary Mater Newcastle, Australia.,School of Mathematical and Physical Science, University of Newcastle, Australia
| |
Collapse
|
5
|
Kim T, Lewis B, Lotey R, Barberi E, Green O. Clinical experience of MRI 4D QUASAR motion phantom for latency measurements in 0.35T MR-LINAC. J Appl Clin Med Phys 2021; 22:128-136. [PMID: 33336884 PMCID: PMC7856488 DOI: 10.1002/acm2.13118] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 11/10/2020] [Accepted: 11/15/2020] [Indexed: 12/25/2022] Open
Abstract
PURPOSE In MRgRT, accuracy of treatment depends on the gating latency, when real-time targeting and gating is enabled. Gating latency is dependent on image acquisition, processing time, accuracy, efficacy of target tracking algorithms, and radiation beam delivery latency. In this report, clinical experience of the MRI4D QUASAR motion phantom for latency measurements on a 0.35-T magnetic resonance-linear accelerator (MR-LINAC) with two imaging speeds and four tracking algorithms was studied. MATERIALS/METHODS Beam-control latency was measured on a 0.35-T MR-LINAC system with four target tracking algorithms and two real-time cine imaging sequences [four and eight frames per second (FPS)]. Using an MR-compatible motion phantom, the delays between phantom beam triggering signal and linac radiation beam control signal were evaluated for three motion periods with a rigid target. The gating point was set to be 8 mm above the full exhalation position. The beam-off latency was measured for a total of 24 combinations of tracking algorithm, imaging FPS, and motion periods. The corresponding gating target margins were determined using the target motion speed multiplied by the beam-off latency. RESULTS The largest measured beam-off latency was 302 ± 20 ms with the Large Deforming Targets (LDT) algorithm and 4 s motion period imaged with 8-FPS cine MRI. The corresponding gating uncertainty based on target motion speed was 3.0 mm. The range of the average beam-off latency was 128-243 ms in 4-FPS imaging and 47-302 ms in 8-FPS imaging. CONCLUSIONS The gating latency was measured using an MRI4D QUASAR motion phantom in a 0.35-T MR-LINAC. The latency measurements include time delay related to MR imaging method, target tracking algorithm and system delay. The gating uncertainty was estimated based on the beam-off latency measurements and the target motion.
Collapse
Affiliation(s)
- Taeho Kim
- Department of Radiation OncologyWashington University School of MedicineSt LouisMOUSA
| | - Benjamin Lewis
- Department of Radiation OncologyWashington University School of MedicineSt LouisMOUSA
| | | | | | - Olga Green
- Department of Radiation OncologyWashington University School of MedicineSt LouisMOUSA
| |
Collapse
|
6
|
Paganelli C, Portoso S, Garau N, Meschini G, Via R, Buizza G, Keall P, Riboldi M, Baroni G. Time-resolved volumetric MRI in MRI-guided radiotherapy: an in silico comparative analysis. Phys Med Biol 2019; 64:185013. [PMID: 31323645 DOI: 10.1088/1361-6560/ab33e5] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
MRI-treatment units enable 2D cine-MRI centred in the tumour for motion detection in radiotherapy, but they lack 3D information due to spatio-temporal limits. To derive time-resolved 3D information, different approaches have been proposed in the literature, but a rigorous comparison among these strategies has not yet been performed. The goal of this study is to quantitatively investigate five published strategies that derive time-resolved volumetric MRI in MRI-guided radiotherapy: Propagation, out-of-plane motion compensation, Fayad model, ROI-based model and Stemkens model. Comparisons were performed using an MRI digital phantom generated with six different patient-derived motion signals and tumour-shapes. An average 4D cycle was generated as well as 2D cine-MRI data with corresponding 3D in-room ground truth. Quantitative analysis was performed by comparing the estimated 3D volume to the ground truth available for each 2D cine-MRI sample. A grouped patient statistical analysis was performed to evaluate the performance of the selected methods, in case of tumour tracking or motion estimation of the whole anatomy. Analyses were also performed based on patient characteristics. Quantitative ranking of the investigated methods highlighted that Propagation and ROI-based model strategies achieved an overall median tumour centre of mass 3D distance from the ground truth of 1.1 mm and 1.3 mm, respectively, and a diaphragm distance below 1.6 mm. Higher errors and variabilities were instead obtained for other methods, which lack the ability to compensate for in-room variations and to account for regional changes. These results were especially evident when further analysing patient characteristics, where errors above 2 mm/5 mm in tumour/diaphragm were found for more irregular breathing patterns in case of out-of-plane motion compensation, Fayad and Stemkens models. These findings suggest the potential of the proposed in silico framework to develop and compare strategies to estimate time-resolved 3DMRI in MRI-guided radiotherapy.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Both authors contributed equally. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Kim T, Park JC, Gach HM, Chun J, Mutic S. Technical Note: Real‐time 3D MRI in the presence of motion for MRI‐guided radiotherapy: 3D Dynamic keyhole imaging with super‐resolution. Med Phys 2019; 46:4631-4638. [DOI: 10.1002/mp.13748] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 06/21/2019] [Accepted: 07/22/2019] [Indexed: 12/11/2022] Open
Affiliation(s)
- Taeho Kim
- Department of Radiation Oncology Washington University School of Medicine St Louis MO 63110USA
| | - Justin C. Park
- Department of Radiation Oncology Washington University School of Medicine St Louis MO 63110USA
| | - H. Michael Gach
- Department of Radiation Oncology Washington University School of Medicine St Louis MO 63110USA
- Department of Radiology and Biomedical Engineering Washington University in St. Louis St Louis MO 63110USA
| | - Jaehee Chun
- Department of Radiation Oncology Yonsei University College of Medicine Seoul 03722South Korea
| | - Sasa Mutic
- Department of Radiation Oncology Washington University School of Medicine St Louis MO 63110USA
| |
Collapse
|
8
|
Lee D, Kim S, Palta J, Lewis B, Keall P, Kim T. A retrospective 4D-MRI based on 2D diaphragm profiles for lung cancer patients. J Med Imaging Radiat Oncol 2019; 63:360-369. [PMID: 30932353 DOI: 10.1111/1754-9485.12877] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Accepted: 02/22/2019] [Indexed: 11/30/2022]
Abstract
INTRODUCTION 4D-MRI, compared to 4D-CT, provides better soft-tissue contrast for target delineation. However, motion artefacts are often observed due to residual breathing variations. This study is to present a retrospective 4D-MRI reconstruction method based on 2D diaphragm profiles to improve the quality of 4D-MR images in the presence of significant breathing variations. METHODS The proposed 4D-MRI reconstruction method utilized diaphragm profiles (2D cine images on a single sagittal plan at the peak diaphragm) in conjunction with 4D-MR scans (2D-cine images on multiple pre-determined coronal planes along the anterior-posterior direction over a volume of interest). The diaphragm profile images were exploited to sort the 4D-MR scans by matching respiratory amplitude of diaphragm on the 4D-MR scans to the diaphragm profiles. To evaluate reconstructed 4D-MR images (ten 3D-MR images), sagittal images on ten 3D-MR images under free breathing (FB) and respiratory guidance (GB) were compared with diaphragm profile images (reference) from 13 healthy volunteers. RESULTS Forty-four 4D-MR scan datasets were successfully reconstructed without distinct respiratory-related motion artefacts even with the presence of breathing variation. The differences in diaphragm profiles between the reference and corresponding reconstructed images in the mean of root mean square were similar between FB (3.5 mm) and GB (3.0 mm), confirming that the 4D-MRI reconstruction method was effective even with significant breathing variation. CONCLUSIONS The diaphragm profiles were utilized to reconstruct 4D-MR images with spatial reliability and a fixed scan time under FB and GB. Our method can provide reliable 4D information of thoracic and abdominal regions for MRI-guided radiotherapy.
Collapse
Affiliation(s)
- Danny Lee
- School of Mathematical and Physical Science, University of Newcastle, Newcastle, New South Wales, Australia
| | - Siyong Kim
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Jatinder Palta
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Benjamin Lewis
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Paul Keall
- Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Taeho Kim
- Radiation Oncology, School of Medicine, Washington University, St. Louis, Missouri, USA
| |
Collapse
|
9
|
Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:169-179. [PMID: 30790140 DOI: 10.1007/s13246-019-00727-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 01/18/2019] [Indexed: 12/25/2022]
Abstract
TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Since both the shallow breathing technique and the clinical use of the BreatheWell device are novel, their implementation requires comprehensive verification and validation work. As the first stage of the validation, this paper investigates the impact of target motion on a TomoTherapy SABR delivery is assessed on both 3D CT and 4D CT using a 4D respiratory phantom. A dosimetric study on a 4D respiratory phantom was conducted, with the phantom's insert designed to move at four different amplitudes in the superior-inferior direction. SABR plans on 3D and 4D CT scans were created and measured. Critical plan statistics and measurement results were compared. It is found that for TomoTherapy SABR deliveries, by reducing the targets respiratory motion, target coverage, organ-at-risk (OAR) sparing, and delivery accuracy were improved.
Collapse
|
10
|
Garau N, Via R, Meschini G, Lee D, Keall P, Riboldi M, Baroni G, Paganelli C. A ROI-based global motion model established on 4DCT and 2D cine-MRI data for MRI-guidance in radiation therapy. Phys Med Biol 2019; 64:045002. [PMID: 30625459 DOI: 10.1088/1361-6560/aafcec] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
In-room magnetic resonance imaging (MRI) allows the acquisition of fast 2D cine-MRI centered in the tumor for advanced motion management in radiotherapy. To achieve 3D information during treatment, patient-specific motion models can be considered the most viable solution. However, conventional global motion models are built using a single motion surrogate, independently from the anatomical location. In this work, we present a novel motion model based on regions of interest (ROIs) established on 4D computed tomography (4DCT) and 2D cine-MRI, aiming at accurately compensating for changes during treatment. In the planning phase, a motion model is built on a 4DCT dataset, through 3D deformable image registration (DIR). ROIs are then defined and correlated with motion fields derived by 2D DIR between CT slices centered in the tumor. In the treatment phase, the model is applied to in-room cine-MRI data to compensate for organ motion in a multi-modal framework, aiming at estimating a time-resolved 3DCT. The method is validated on a digital phantom and tested on two lung patients. Analysis is performed by considering different anatomical planes (coronal, sagittal and a combination of the two) and evaluating the performance of the method on tumor and diaphragm. For the phantom study, the ROI-based model results in a uniform median error on both diaphragm and tumor below 1.5 mm. For what concerns patients, median errors on both diaphragm and tumor are around 2 mm (maximum patient resolution), confirming the capability of the method to regionally compensate for motion. A novel ROI-based motion model is proposed as an integral part of an envisioned clinical MRI-guided workflow aiming at enhanced image guidance compared to conventional strategies.
Collapse
Affiliation(s)
- Noemi Garau
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Paganelli C, Whelan B, Peroni M, Summers P, Fast M, van de Lindt T, McClelland J, Eiben B, Keall P, Lomax T, Riboldi M, Baroni G. MRI-guidance for motion management in external beam radiotherapy: current status and future challenges. Phys Med Biol 2018; 63:22TR03. [PMID: 30457121 DOI: 10.1088/1361-6560/aaebcf] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
High precision conformal radiotherapy requires sophisticated imaging techniques to aid in target localisation for planning and treatment, particularly when organ motion due to respiration is involved. X-ray based imaging is a well-established standard for radiotherapy treatments. Over the last few years, the ability of magnetic resonance imaging (MRI) to provide radiation-free images with high-resolution and superb soft tissue contrast has highlighted the potential of this imaging modality for radiotherapy treatment planning and motion management. In addition, these advantageous properties motivated several recent developments towards combined MRI radiation therapy treatment units, enabling in-room MRI-guidance and treatment adaptation. The aim of this review is to provide an overview of the state-of-the-art in MRI-based image guidance for organ motion management in external beam radiotherapy. Methodological aspects of MRI for organ motion management are reviewed and their application in treatment planning, in-room guidance and adaptive radiotherapy described. Finally, a roadmap for an optimal use of MRI-guidance is highlighted and future challenges are discussed.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Author to whom any correspondence should be addressed. www.cartcas.polimi.it
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
van Sörnsen de Koste JR, Palacios MA, Bruynzeel AME, Slotman BJ, Senan S, Lagerwaard FJ. MR-guided Gated Stereotactic Radiation Therapy Delivery for Lung, Adrenal, and Pancreatic Tumors: A Geometric Analysis. Int J Radiat Oncol Biol Phys 2018; 102:858-866. [PMID: 30061007 DOI: 10.1016/j.ijrobp.2018.05.048] [Citation(s) in RCA: 106] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 12/11/2017] [Accepted: 05/16/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE We implemented magnetic resonance-guided breath-hold stereotactic body radiation therapy in combination with visual feedback using the MRIdian system. Both accuracy of gated delivery and reproducibility of tumor positions were studied. METHODS AND MATERIALS Tumor tracking is realized through repeated magnetic resonance imaging in a single sagittal plane at 4 frames per second with deformable image registration. An in-room monitor allowed visualization of the tracked gross tumor volume (GTV) contour and the planning target volume (PTV) (GTV + 3 mm), which was the gating boundary. For each delivery, a predefined threshold-region of interest percentage (ROI%) allows a percentage of GTV area to be outside the gating boundary before a beam-hold is triggered. Accuracy of gated delivery and tumor position reproducibility during breath-holds was analyzed for 15 patients (87 fractions) with lung, adrenal, and pancreas tumors. For each fraction, we analyzed (1) reproducibility of system-tracked GTV centroid position within the PTV; (2) geometric coverage of GTV area within the PTV; (3) treatment duty cycle efficiency; (4) effects of threshold ROI% settings on treatment duty cycle efficiency and GTV area coverage; and (5) beam-off latency effect on mean GTV coverage. RESULTS For lung, adrenal, and pancreatic tumors, grouped 5th to 95th percentile distributions of GTV centroid positions in the dorsoventral direction, relative to PTV-center of mass (COM), were, respectively, -3.3 mm to 2.8 mm, -2.5 mm to 3.7 mm, and -4.4 mm to 2.9 mm. Corresponding distributions in the craniocaudal direction were -2.6 mm to 4.6 mm, -4.1 mm to 4.4 mm, and -4.4 mm to 4.5 mm, respectively. Mean GTV areas encompassed during beam-on for all fractions were 94.6%, 94.3%, and 95.3% for lung, adrenal, and pancreas tumors, respectively. Mean treatment duty cycle efficiency ranged from 67% to 87% for these tumors. Use of higher threshold-ROI% resulted in increased duty cycle efficiency, at the cost of a small decrease in GTV area coverage. The beam-off latency had a marginal impact on the GTV coverage. CONCLUSIONS Gated stereotactic body radiation therapy delivery during breath-hold, real-time magnetic resonance guidance resulted in at least 95% geometric GTV coverage in lung, adrenal, and pancreatic tumors.
Collapse
Affiliation(s)
| | - Miguel A Palacios
- Department of Radiation Oncology, VU medical center, Amsterdam, The Netherlands
| | - Anna M E Bruynzeel
- Department of Radiation Oncology, VU medical center, Amsterdam, The Netherlands
| | - Ben J Slotman
- Department of Radiation Oncology, VU medical center, Amsterdam, The Netherlands
| | - Suresh Senan
- Department of Radiation Oncology, VU medical center, Amsterdam, The Netherlands
| | - Frank J Lagerwaard
- Department of Radiation Oncology, VU medical center, Amsterdam, The Netherlands
| |
Collapse
|
13
|
Paganelli C, Kipritidis J, Lee D, Baroni G, Keall P, Riboldi M. Image‐based retrospective 4D
MRI
in external beam radiotherapy: A comparative study with a digital phantom. Med Phys 2018; 45:3161-3172. [DOI: 10.1002/mp.12965] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 04/30/2018] [Accepted: 05/03/2018] [Indexed: 12/16/2022] Open
Affiliation(s)
- Chiara Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano Milano 20133 Italy
| | - John Kipritidis
- Northern Sydney Cancer Centre Royal North Shore Hospital Sydney NSW 2065 Australia
- ACRF Image X Institute Sydney Medical School University of Sydney Sydney NSW 2015 Australia
| | - Danny Lee
- Department of Radiation Oncology Calvary Mater Newcastle Newcastle NSW 2298 Australia
| | - Guido Baroni
- Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano Milano 20133 Italy
- Centro Nazionale di Adroterapia Oncologica Pavia 27100 Italy
| | - Paul Keall
- ACRF Image X Institute Sydney Medical School University of Sydney Sydney NSW 2015 Australia
| | - Marco Riboldi
- Department of Medical Physics Ludwig‐Maximilians‐Universitat Munchen Munich 80539 Germany
| |
Collapse
|
14
|
Lee D, Greer PB, Paganelli C, Ludbrook JJ, Kim T, Keall P. Audiovisual biofeedback improves the correlation between internal/external surrogate motion and lung tumor motion. Med Phys 2018; 45:1009-1017. [DOI: 10.1002/mp.12758] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 12/03/2017] [Accepted: 12/24/2017] [Indexed: 12/25/2022] Open
Affiliation(s)
- Danny Lee
- School of Mathematical and Physical Sciences; The University of Newcastle; Callaghan NSW Australia
| | - Peter B. Greer
- School of Mathematical and Physical Sciences; The University of Newcastle; Callaghan NSW Australia
- Department of Radiation Oncology; Calvary Mater Newcastle; Waratah NSW Australia
| | - Chiara Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria; Politecnico di Milano; Milan Italy
| | - Joanna Jane Ludbrook
- Department of Radiation Oncology; Calvary Mater Newcastle; Waratah NSW Australia
| | - Taeho Kim
- Department of Radiation Oncology; Virginia Commonwealth University; Richmond VA USA
| | - Paul Keall
- ACRF Image X Institute; Sydney Medical School; University of Sydney; Sydney NSW Australia
| |
Collapse
|
15
|
Pollock S, Tse R, Martin D, McLean L, Pham M, Tait D, Estoesta R, Whittington G, Turley J, Kearney C, Cho G, Hill R, Pickard S, Aston P, Makhija K, O'Brien R, Keall P. Impact of audiovisual biofeedback on interfraction respiratory motion reproducibility in liver cancer stereotactic body radiotherapy. J Med Imaging Radiat Oncol 2018; 62:133-139. [PMID: 29405637 DOI: 10.1111/1754-9485.12702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 11/28/2017] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Irregular breathing motion exacerbates uncertainties throughout a course of radiation therapy. Breathing guidance has demonstrated to improve breathing motion consistency. This was the first clinical implementation of audiovisual biofeedback (AVB) breathing guidance over a course of liver stereotactic body radiotherapy (SBRT) investigating interfraction reproducibility. METHODS Five liver cancer patients underwent a screening procedure prior to CT sim during which patients underwent breathing conditions (i) AVB, or (ii) free breathing (FB). Whichever breathing condition was more regular was utilised for the patient's subsequent course of SBRT. Respiratory motion was obtained from the Varian respiratory position monitoring (RPM) system (Varian Medical Systems). Breathing motion reproducibility was assessed by the variance of displacement across 10 phase-based respiratory bins over each patient's course of SBRT. RESULTS The screening procedure yielded the decision to utilise AVB for three patients and FB for two patients. Over the course of SBRT, AVB significantly improved the relative interfraction motion by 32%, from 22% displacement difference for FB patients to 15% difference for AVB patients. Further to this, AVB facilitated sub-millimetre interfraction reproducibility for two AVB patients. CONCLUSION There was significantly less interfraction motion with AVB than FB. These findings demonstrate that AVB is potentially a valuable tool in ensuring reproducible interfraction motion.
Collapse
Affiliation(s)
- Sean Pollock
- Sydney Medical School - Central, University of Sydney, Sydney, New South Wales, Australia
| | - Regina Tse
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Darren Martin
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Lisa McLean
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Melissa Pham
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - David Tait
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Reuben Estoesta
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Grant Whittington
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Jessica Turley
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Christopher Kearney
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Gwi Cho
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Robin Hill
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia.,Institute of Medical Physics, School of Physics, University of Sydney, New South Wales, Australia
| | - Sheila Pickard
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Paul Aston
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Sydney, New South Wales, Australia
| | - Kuldeep Makhija
- Sydney Medical School - Central, University of Sydney, Sydney, New South Wales, Australia
| | - Ricky O'Brien
- Sydney Medical School - Central, University of Sydney, Sydney, New South Wales, Australia
| | - Paul Keall
- Sydney Medical School - Central, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
16
|
Tseng YD, Wootton L, Nyflot M, Apisarnthanarax S, Rengan R, Bloch C, Sandison G, St. James S. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion? ACTA ACUST UNITED AC 2018; 63:02NT03. [DOI: 10.1088/1361-6560/aaa44e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
17
|
Park S, Farah R, Shea SM, Tryggestad E, Hales R, Lee J. Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning. Phys Med Biol 2018; 63:025015. [PMID: 29243669 DOI: 10.1088/1361-6560/aaa20b] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Respiration-induced tumor motion is a major obstacle for achieving high-precision radiotherapy of cancers in the thoracic and abdominal regions. Surrogate-based estimation and tracking methods are commonly used in radiotherapy, but with limited understanding of quantified correlation to tumor motion. In this study, we propose a method to simultaneously track the lung tumor and external surrogates to evaluate their spatial correlation in a quantitative way using dynamic MRI, which allows real-time acquisition without ionizing radiation exposure. To capture the lung and whole tumor, four MRI-compatible fiducials are placed on the patient's chest and upper abdomen. Two different types of acquisitions are performed in the sagittal orientation including multi-slice 2D cine MRIs to reconstruct 4D-MRI and two-slice 2D cine MRIs to simultaneously track the tumor and fiducials. A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and groupwise registration. The 4D-MRI provides 3D template volumes for different breathing phases. 3D tumor position is calculated by 3D-2D template matching in which 3D tumor templates in the 4D-MRI reconstruction and the 2D cine MRIs from the two-slice tracking dataset are registered. 3D trajectories of the external surrogates are derived via matching a 3D geometrical model of the fiducials to their segmentations on the 2D cine MRIs. We tested our method on ten lung cancer patients. Using a correlation analysis, the 3D tumor trajectory demonstrates a noticeable phase mismatch and significant cycle-to-cycle motion variation, while the external surrogate was not sensitive enough to capture such variations. Additionally, there was significant phase mismatch between surrogate signals obtained from the fiducials at different locations.
Collapse
Affiliation(s)
- Seyoun Park
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, United States of America
| | | | | | | | | | | |
Collapse
|
18
|
Fast MF, Eiben B, Menten MJ, Wetscherek A, Hawkes DJ, McClelland JR, Oelfke U. Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study. Radiother Oncol 2017; 125:485-491. [PMID: 29029832 PMCID: PMC5736170 DOI: 10.1016/j.radonc.2017.09.013] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 08/11/2017] [Accepted: 09/13/2017] [Indexed: 11/25/2022]
Abstract
BACKGROUND AND PURPOSE Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients. MATERIAL AND METHODS Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty. RESULTS Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ⩾0.91). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance. CONCLUSION Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance.
Collapse
Affiliation(s)
- Martin F Fast
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom.
| | - Björn Eiben
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom.
| | - Martin J Menten
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Andreas Wetscherek
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - David J Hawkes
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Jamie R McClelland
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Uwe Oelfke
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
19
|
Lee D, Kim S, Palta JR, Kim T. Technical note: real-time web-based wireless visual guidance system for radiotherapy. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:463-469. [PMID: 28425075 DOI: 10.1007/s13246-017-0548-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 04/03/2017] [Indexed: 10/19/2022]
Abstract
Describe a Web-based wireless visual guidance system that mitigates issues associated with hard-wired audio-visual aided patient interactive motion management systems that are cumbersome to use in routine clinical practice. Web-based wireless visual display duplicates an existing visual display of a respiratory-motion management system for visual guidance. The visual display of the existing system is sent to legacy Web clients over a private wireless network, thereby allowing a wireless setting for real-time visual guidance. In this study, active breathing coordinator (ABC) trace was used as an input for visual display, which captured and transmitted to Web clients. Virtual reality goggles require two (left and right eye view) images for visual display. We investigated the performance of Web-based wireless visual guidance by quantifying (1) the network latency of visual displays between an ABC computer display and Web clients of a laptop, an iPad mini 2 and an iPhone 6, and (2) the frame rate of visual display on the Web clients in frames per second (fps). The network latency of visual display between the ABC computer and Web clients was about 100 ms and the frame rate was 14.0 fps (laptop), 9.2 fps (iPad mini 2) and 11.2 fps (iPhone 6). In addition, visual display for virtual reality goggles was successfully shown on the iPhone 6 with 100 ms and 11.2 fps. A high network security was maintained by utilizing the private network configuration. This study demonstrated that a Web-based wireless visual guidance can be a promising technique for clinical motion management systems, which require real-time visual display of their outputs. Based on the results of this study, our approach has the potential to reduce clutter associated with wired-systems, reduce space requirements, and extend the use of medical devices from static usage to interactive and dynamic usage in a radiotherapy treatment vault.
Collapse
Affiliation(s)
- Danny Lee
- Department of Radiation Oncology, Virginia Commonwealth University, 401 College Street, P.O. Box 980058, Richmond, VA, 23298-0058, USA
| | - Siyong Kim
- Department of Radiation Oncology, Virginia Commonwealth University, 401 College Street, P.O. Box 980058, Richmond, VA, 23298-0058, USA
| | - Jatinder R Palta
- Department of Radiation Oncology, Virginia Commonwealth University, 401 College Street, P.O. Box 980058, Richmond, VA, 23298-0058, USA
| | - Taeho Kim
- Department of Radiation Oncology, Virginia Commonwealth University, 401 College Street, P.O. Box 980058, Richmond, VA, 23298-0058, USA.
| |
Collapse
|
20
|
Bourque AE, Carrier JF, Filion É, Bedwani S. A particle filter motion prediction algorithm based on an autoregressive model for real-time MRI-guided radiotherapy of lung cancer. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa6b5b] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
21
|
Pollock S, Kipritidis J, Lee D, Bernatowicz K, Keall P. The impact of breathing guidance and prospective gating during thoracic 4DCT imaging: an XCAT study utilizing lung cancer patient motion. Phys Med Biol 2016; 61:6485-501. [DOI: 10.1088/0031-9155/61/17/6485] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
22
|
Baba F, Tanaka S, Nonogaki Y, Hasegawa S, Nishihashi M, Ayakawa S, Yamada M, Shibamoto Y. Effects of audio coaching and visual feedback on the stability of respiration during radiotherapy. Jpn J Radiol 2016; 34:572-8. [DOI: 10.1007/s11604-016-0560-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 05/30/2016] [Indexed: 01/25/2023]
|
23
|
Sierra Murguía MA, Padilla Rico A, Fraga Sastrías JM. Uso de biofeedback de variabilidad de la frecuencia cardiaca durante la radioterapia como método de distracción cognitiva y autorregulación en un paciente pediátrico: Informe de caso. PSICOONCOLOGIA 1970. [DOI: 10.5209/psic.57084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Objetivo: Evaluar la efectividad del uso de biofeedback de variabilidad de frecuencia cardiaca (VFC) durante la radioterapia como método de distracción cognitiva y autoregulación emocional en un paciente pediátrico. Método: La paciente es una niña de 11 años con diagnóstico de sarcoma de Ewing en la pierna izquierda. Recibió 28 sesiones de radioterapia. Antes de iniciar tratamiento, se evaluó psicológicamente a la paciente con la entrevista Mini Kid, identificando que no tenía psicopatología. Dos semanas previas a iniciar, se evaluó la frecuencia cardiaca (FC) y variabilidad (VFC) de la misma (indicadores que han sido utilizados previamente como correlatos fisiológicos de estrés y relajación) con un software especializado llamado EmWave, identificando que sí presentaba activación fisiológica asociada a estrés. Se hizo entrenamiento en respiración diafragmática apoyado con el equipo de retroalimentación dos semanas previas a la radioterapia. El día que inició tratamiento, se volvió a evaluar la frecuencia y variabilidad antes de comenzar. Durante la radioterapia se instrumentó a la paciente al software y se permitió que ella escogiera el juego (que registra las variables de FC y VFC e interactúa conforme ella logra autoregulación fisiológica) y éste era proyectado en el techo de la sala mientras recibía la radiación. Resultados: Se identificaron cambios en la variabilidad de la frecuencia cardiaca, logrando una autoregulación, mostrando así que la paciente aprendió a relajarse y que lo puso en práctica durante la radioterapia. Conclusión: El uso del biofeedback es innovador en el tratamiento con radioterapia; permite al paciente integrar los dos métodos más utilizados como preparación para la misma: distraer el foco atencional y lograr una autoregulación. Se sugiere ampliar la muestra para conocer los efectos y generalizar los resultados.
Collapse
|